Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,658 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Special notice, first published as sources sought

EMERGENCY REPAIR - CAREN Motion Platform - PGH | EDA: 1/31/25

36C24E25Q0024

Department of Veterans Affairs, Rpo East. Electromedical and Electrotherapeutic Apparatus Manufacturing.

Response deadline

January 14, 2025 at 3:00 PM EST

Closed 680 days ago. Posted January 14, 2025, first published January 7, 2025. Scheduled to archive April 29, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

12 like it are open now in electromedical and electrotherapeutic apparatus manufacturing

All 12 open in electromedical and electrotherapeutic apparatus manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary
What comes next
No solicitation was published under this number after the sources sought of January 7, 2025. An agency sometimes issues the solicitation under a new number.

Description

As published on SAM.gov.

Pre-Solicitation Notice for notice of intent to award a sole source contract. This is not a solicitation. The Department of Veterans Affairs intends to negotiate a sole source contract for parts and repair with Hocoma Inc., 77 Accord Park Dr., Suite D-1 Norwell, MA 02061 for parts and repair on an existing device called the computer-assisted rehabilitation environment (CAREN) system in the Veterans Affairs Pittsburgh Healthcare System (VAPHS) Human Engineering Research Laboratories (HERL), located at 6425 Penn Avenue, 4th Floor, Suite 400, Pittsburgh, PA 15206. The CAREN system is a unique computer design that allows Veterans to test prosthetic devices used for balance in a virtual simulation that mimics rougher terrain, such as walking on a trail, a bumpy sidewalk, up and down hills, or across slopes. Its purpose is to help prevent falls and sustain patients lives. The motion base and transformers malfunctioned rendering the entire device inert. Only certain pieces of the whole system will be replaced. The system requires replacement of the following items: 6D0F Motion Base Transformer Wesemann 21804706 3-Phase | 208/400/480V | 400V| 17.5KVA | Cabinet incl. pre-magn. | UL Materials Isolation transformer - 1 phase 4 x 16 A Set Projector Optoma ZH450ST Freight charges Project Management (Research) Service visit day 1 per person Service visit extra day per person The requirement is for the contractor to provide shipment and delivery of required supplies, installation of new pieces, and testing of system by an authorized experienced trained technician to ensure it is fully functional. This procurement shall be inclusive of shipping and handling charges (FBO Destination) and the below requirements. Deliver Inspiration and Health (DIH) Technology will ship the required pieces to repair the existing CAREN system, and they will also send a specially trained technician for installation. The Contractor is fully responsible for planning the shipment and delivery of the components. The Contractor will deliver materials to job in manufacturer's original sealed packaging, packaged to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary. Deliver specified items only when the site is ready for installation work to proceed. Store products in dry condition inside enclosed facilities. A pre-delivery meeting will be conducted 60 days prior to initial negotiated delivery date for verification of delivery and installation dates. Provide a fully trained experienced technician to fully install the new components to the existing CAREN system. It is agreed upon and understood that the contractor shall be responsible for a complete installation. Install all equipment to manufacturer s specifications maintaining Federal, and Local safety standards. The contractor shall coordinate all deliveries, staging areas, installations, and parking arrangements. The Contractor shall remove all related shipping debris and cleanup any construction associated with delivery and installation of the specified items. The packing materials will be placed in the facility provided dumpster. The Contractor shall be responsible for any damage to the building that occurs due to Contractor error or neglect. Contractor must provide a two-week window for installation of units. We will be able to choose the installation date from this window. This will allow us to choose the date with the least impact to the research staff. In the event no practical install dates can be found in this window the vendor will extend the window for up to four-weeks. The Contractor technician will test the CAREN system to ensure full functionality. Upon completing installation of the system, the Contractor shall pretest the entire system. After pretesting the system, the Contractor shall notify the SME that the system is ready for acceptance testing, and that it meets all requirements as specified. Submission of this notification of system readiness shall be accomplished by the contractor prior to the beginning of the scheduled Government Acceptance Test. This must occur the same week of the install. The Contractor shall conduct a joint inspection with the SME upon delivery of equipment. Due to the highly specialized technical equipment of the CAREN system and the required trained technical experience needed to repair this system, Homoca Inc, the original equipment manufacturer (OEM) is the only Vendor that can provide the parts and repair services required for this system. Since the intent is to procure this on a sole source basis, no solicitation will be posted in SAM.Gov under Contract Opportunities. A Sources Sought Notice published to FBO on 01/07/2025 under #36C24E25Q0024 returned no results other than from the OEM, Homoca, Inc. The applicable NAICS code is 334510 with a 1250 employee size standard. The PSC is 6525. The authority for this action is FAR 6.302.1-1 Only One Responsible source and no other supplies or services will satisfy agency requirements. Interested persons may contact the Contracting Officer, Ann Marie Stewart via email at annmarie.stewart@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. January 7, 2025

    Sources sought

    REPAIR - Computer-Assisted Rehabilitation Environment -CAREN- Motion Platform System

    Due January 14, 2025 at 3:00 PM EST. SAM.gov, notice d825e567633244cfb8c521edc23b6ecf

  2. January 14, 2025

    Special notice, originally sources sought

    Due January 20, 2025 at 3:00 PM EST. SAM.gov, notice f68198459c174cd398c49ce26df13ad3

    2 revisions on SAM
    • January 14, 2025: publish, special notice
    • January 7, 2025: publish, sources sought

Points of contact