{"canonical":"https://sealedbidder.com/opportunities/36c24926q0345","key":"36C24926Q0345","url":"https://sealedbidder.com/opportunities/36c24926q0345","title":"J041-- AHU Repairs Alvin C York VAMC","solicitation_number":"36C24926Q0345","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-12T20:00:00Z","first_posted":"2026-08-05","last_posted":"2026-08-05","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"238220","psc":"J041","set_aside":"SBA","place_state":"TN","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"47149","place_county_name":"Rutherford County","place_city":"4751560","place_city_name":"Murfreesboro","winner":null,"award_amount":null,"publications":[{"notice_id":"a3e0388f5f0d4c39be6f85293280caf0","title":"J041-- AHU Repairs Alvin C York VAMC","solicitation_number":"36C24926Q0345","notice_type":"r","base_type":"r","posted":"2026-08-05","posted_at":"2026-08-05T15:44:03.370Z","due_at":"2026-08-12T20:00:00Z","due_date":"2026-08-12","cancelled":false,"archived":true,"archive_date":"2026-08-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a3e0388f5f0d4c39be6f85293280caf0/view","enriched":true,"history":[{"index":3,"title":"J041-- AHU Repairs Alvin C York VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T15:44:03.370Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a3e0388f5f0d4c39be6f85293280caf0","solicitation_number":"36C24926Q0345"}]}],"latest_notice_id":"a3e0388f5f0d4c39be6f85293280caf0","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-05","posted_at":"2026-08-05T15:44:03.370Z","created_at":"2026-08-05T15:44:01.058Z","modified_at":"2026-08-22T05:06:37.264Z","response_deadline":{"raw":"2026-08-12T15:00:00-05:00","utc":"2026-08-12T20:00:00Z","date":"2026-08-12","time":"15:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a3e0388f5f0d4c39be6f85293280caf0/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J041-- AHU Repairs Alvin C York VAMC","agency":{"office":{"code":"36C249","name":"249-NETWORK CONTRACT OFFICE 9 (36C249)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"organization_id":"100163849","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-22","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041-- AHU Repairs Alvin C York VAMC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T15:44:03.370Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a3e0388f5f0d4c39be6f85293280caf0","solicitation_number":"36C24926Q0345"}],"contacts":[{"name":"Shania Kimbrough","role":"primary","email":"shania.kimbrough@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"a3e0388f5f0d4c39be6f85293280caf0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"a3e0388f5f0d4c39be6f85293280caf0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T02:44:35.509457044Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"1267de52dee9811f4d0850bcd7c1f6df71faf074de73835bbcb8078b946d6d0f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T02:44:35.509457044Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This is a sources sought announcement only. It is neither a solicitation announcement nor a request for\nproposals or quotes and does not obligate the Government to award a contract. Responses in this\nsources sought notice must be in writing. The purpose of this sources sought announcement is for\nmarket research to make appropriate acquisition decisions and to gain knowledge of potential\nbusinesses interested and capable of providing the services described below.\n\n\n\nSTATEMENT OF WORK\nDepartment of Veterans Affairs\nTVHS, Alvin C York Campus\nRefurbish Air Handling Units\nPURPOSE\nThe purpose of this contract is to provide all labor, materials, supervision, tools, and equipment necessary to inspect, clean, conduct coil restoration, refurbish, and seal floors, walls, and blowers to meet NFPA 90A requirements on nine (9) Air Handling Units (AHU s) at the historic York Campus of the VA Tennessee Valley Healthcare System, 3400 Lebanon Pike, Murfreesboro, TN 37129 in accordance with the SOW, specifications, drawings and manufacturer recommendations.\nEQUIPMENT DESCRIPTION\nThe work under this contract applies to the following Air Handling Units:\nAHU-14 (Bldg 117 Main Roof)\nAHU-16 (Bldg 3)\nAHU-17 (Bldg 3)\nAHU-27 (Bldg 10 Ground Floor)\nAHU-28 (Bldg 10)\nAHU-29 (Bldg 11 MR G09)\nAHU-29B (Bldg 2)\nAHU-10 (Bldg 2)\nAHU-15 (Bldg 120)\nThe contractor shall be familiar with Cleaver-Brooks firetube boiler refractory systems, including burner throat, furnace, rear door, and turnaround areas.\nSCOPE OF WORK\nInspection & Assessment\nAging Mechanical Equipment\nStanding water\nRust/Corrosion of condensate pans and floors\nWater leaks\nCoil condition\nFire Code Compliance\nCoordinate with customer to determine best times/methods to de-energize AHU s.\nDemolition & Removal\nInspect AHU s units:\nClean and prepare all surfaces that will be addressed by the contractor including removal of non-compliant coatings and foams\n\nDispose of materials per VA, OSHA, and EPA regulations\nProtect motors, fans, ductwork, sensors, UV lights and coils from damage\n\n\nInstallation and New Work\nCoil Restoration on all coils\nMeasure pressure drop (PD) as allowable\nUse environmentally friendly probiotic foam\nSanitize coils\nRepeat probiotic application and sanitize\nRemeasure AHU PD\nB Install SealTech system on floors, walls, blowers:\nReinforce compromised floors with steel as needed to restore structure to the floors\nSealTech Epoxy (self-leveling) at 3/16  nominal thickness and 6  up walls throughout all chamber floors and condensate pans\nApply Fire Barrier\nApply  Antimicrobial Topcoat over all fire barriers\nApply Multi-acrylic, corrosion resistant, antimicrobial coating (MVS) on walls, ceiling, fan housing and structural steel throughout areas addressed with CPR-SL (does not include AHU-14)\nIsolate AHU by sealing off adjacent ductwork\n\nTesting & Commissioning\nA Confirm proper operation of existing CFM, drains, and traps prior to re-commissioning\nGenerate detailed Installation Report, which includes results from PD reading and ATP Testing\nPERFORMANCE REQUIREMENTS\nAll work shall comply with:\nNFPA standards\nASHRAE standards\nOSHA safety regulations\nVA Engineering and Environment of Care requirements\nWork shall maintain continuity of conditioned air for patient care operations\nSCHEDULING & OUTAGE COORDINATION\n\nWork shall be scheduled during approved outage window from 8 am- 4 pm during week workdays\nContractor shall:\nMinimize impact on facility by conducting installation during nights and weeks (when required)\nProvide adequate staffing for critical timelines\nCoordinate Engineering and Maintenance and Operations (M&O)\nSUBMITTALS\nContractor shall provide:\nMaterial specifications (OEM-compliant)\nSafety plan (LOTO, confined space, hot work)\nWork schedule and outage plan\nInspection and deficiency report\nFinal completion and commissioning report\nSAFETY REQUIREMENTS\nComply with VA Lockout/Tagout (LOTO) procedures (if required)\nFollow confined space entry protocols\nUse required PPE (respiratory, thermal, arc-flash as applicable)\nImplement fire watch during hot work\nQUALITY ASSURANCE\nA Contractor must:\nHave minimum 5 years  experience with air handling unit refurbishments\nAll work subject to inspection by VA Engineering Service\nWARRANTY\nThe contractor shall provide a minimum ten (10) year warranty from the date of final acceptance by VA Engineering Service.\nCoverage\nThe warranty shall include:\nAll refractory materials installed\nAll labor and workmanship\nAnchoring systems and insulation components\n\nContractor Responsibility\nA           The contractor shall repair or replace, at no additional cost to the Government, any defective:\nMaterials\nInstallation\nWorkmanship\nB            Corrections shall be completed within a reasonable timeframe as determined by the Contracting    Officer and Engineering Service.\nResponse Time\nContractor shall respond to warranty issues within:\n24 hours for critical failures impacting operations\n72 hours for non-critical issues\nExclusions\nThe warranty shall not apply to failures caused by:\nImproper operation by Government personnel\nUnauthorized modifications\nConditions outside normal operating parameters\nDocumentation\nContractor shall provide written warranty documentation upon installation completion\nWarranty start date shall be the date of final acceptance and return to service\nFailure Impact Clause (Recommended for VA)\nIf refractory failure occurs during the warranty period and results in:\nAir Handling Unit outage\nImpact on patient care \nThe contractor shall:\nProvide priority response and repair\nCoordinate with VA staff to minimize downtime\nDELIVERABLES\nFully restored AHU system\nAir Handling Unit returned to safe and efficient operation\n\nComplete documentation package\nJUSTIFICATION (Procurement Support)\nRefurbishment of selected Air Handling Units will result in improved Energy savings, Air Quality, meet NFPA and ASHRAE requirements and allow continuous operation of conditioned air to affected spaces until replacement projects can be executed.\n\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding\nto this sources sought announcement. This notice shall not be construed as a commitment by the\nGovernment to issue a solicitation or ultimately award a contract, nor does it restrict the Government\nto a particular acquisition approach. The Government will in no way be bound to this information if any\nsolicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service\nDisabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran\nOwned Small Business responses, an alternate set-aside or full and open competition may be\ndetermined. No sub-contracting opportunity is anticipated.\nThe North American Classification System (NAICS) code for this acquisition is 238220   Plumbing, Heating, and Air-Conditioning Contractors ($19 M).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal\nGovernment must be registered in the System for Award Management (SAM) at www.sam.gov.\nAdditionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses\nmust be registered with U.S. Small Business Administration (SBA) located at\nhttp://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Shania.kimbrough@va.gov. Telephone\nresponses will not be accepted.\nResponses must be received no later than 08/12/2025 15:00 PM CST.","text":"This is a sources sought announcement only. It is neither a solicitation announcement nor a request for\nproposals or quotes and does not obligate the Government to award a contract. Responses in this\nsources sought notice must be in writing. The purpose of this sources sought announcement is for\nmarket research to make appropriate acquisition decisions and to gain knowledge of potential\nbusinesses interested and capable of providing the services described below.\n\nSTATEMENT OF WORK\nDepartment of Veterans Affairs\nTVHS, Alvin C York Campus\nRefurbish Air Handling Units\nPURPOSE\nThe purpose of this contract is to provide all labor, materials, supervision, tools, and equipment necessary to inspect, clean, conduct coil restoration, refurbish, and seal floors, walls, and blowers to meet NFPA 90A requirements on nine (9) Air Handling Units (AHU s) at the historic York Campus of the VA Tennessee Valley Healthcare System, 3400 Lebanon Pike, Murfreesboro, TN 37129 in accordance with the SOW, specifications, drawings and manufacturer recommendations.\nEQUIPMENT DESCRIPTION\nThe work under this contract applies to the following Air Handling Units:\nAHU-14 (Bldg 117 Main Roof)\nAHU-16 (Bldg 3)\nAHU-17 (Bldg 3)\nAHU-27 (Bldg 10 Ground Floor)\nAHU-28 (Bldg 10)\nAHU-29 (Bldg 11 MR G09)\nAHU-29B (Bldg 2)\nAHU-10 (Bldg 2)\nAHU-15 (Bldg 120)\nThe contractor shall be familiar with Cleaver-Brooks firetube boiler refractory systems, including burner throat, furnace, rear door, and turnaround areas.\nSCOPE OF WORK\nInspection & Assessment\nAging Mechanical Equipment\nStanding water\nRust/Corrosion of condensate pans and floors\nWater leaks\nCoil condition\nFire Code Compliance\nCoordinate with customer to determine best times/methods to de-energize AHU s.\nDemolition & Removal\nInspect AHU s units:\nClean and prepare all surfaces that will be addressed by the contractor including removal of non-compliant coatings and foams\n\nDispose of materials per VA, OSHA, and EPA regulations\nProtect motors, fans, ductwork, sensors, UV lights and coils from damage\n\nInstallation and New Work\nCoil Restoration on all coils\nMeasure pressure drop (PD) as allowable\nUse environmentally friendly probiotic foam\nSanitize coils\nRepeat probiotic application and sanitize\nRemeasure AHU PD\nB Install SealTech system on floors, walls, blowers:\nReinforce compromised floors with steel as needed to restore structure to the floors\nSealTech Epoxy (self-leveling) at 3/16 nominal thickness and 6 up walls throughout all chamber floors and condensate pans\nApply Fire Barrier\nApply Antimicrobial Topcoat over all fire barriers\nApply Multi-acrylic, corrosion resistant, antimicrobial coating (MVS) on walls, ceiling, fan housing and structural steel throughout areas addressed with CPR-SL (does not include AHU-14)\nIsolate AHU by sealing off adjacent ductwork\n\nTesting & Commissioning\nA Confirm proper operation of existing CFM, drains, and traps prior to re-commissioning\nGenerate detailed Installation Report, which includes results from PD reading and ATP Testing\nPERFORMANCE REQUIREMENTS\nAll work shall comply with:\nNFPA standards\nASHRAE standards\nOSHA safety regulations\nVA Engineering and Environment of Care requirements\nWork shall maintain continuity of conditioned air for patient care operations\nSCHEDULING & OUTAGE COORDINATION\n\nWork shall be scheduled during approved outage window from 8 am- 4 pm during week workdays\nContractor shall:\nMinimize impact on facility by conducting installation during nights and weeks (when required)\nProvide adequate staffing for critical timelines\nCoordinate Engineering and Maintenance and Operations (M&O)\nSUBMITTALS\nContractor shall provide:\nMaterial specifications (OEM-compliant)\nSafety plan (LOTO, confined space, hot work)\nWork schedule and outage plan\nInspection and deficiency report\nFinal completion and commissioning report\nSAFETY REQUIREMENTS\nComply with VA Lockout/Tagout (LOTO) procedures (if required)\nFollow confined space entry protocols\nUse required PPE (respiratory, thermal, arc-flash as applicable)\nImplement fire watch during hot work\nQUALITY ASSURANCE\nA Contractor must:\nHave minimum 5 years experience with air handling unit refurbishments\nAll work subject to inspection by VA Engineering Service\nWARRANTY\nThe contractor shall provide a minimum ten (10) year warranty from the date of final acceptance by VA Engineering Service.\nCoverage\nThe warranty shall include:\nAll refractory materials installed\nAll labor and workmanship\nAnchoring systems and insulation components\n\nContractor Responsibility\nA The contractor shall repair or replace, at no additional cost to the Government, any defective:\nMaterials\nInstallation\nWorkmanship\nB Corrections shall be completed within a reasonable timeframe as determined by the Contracting Officer and Engineering Service.\nResponse Time\nContractor shall respond to warranty issues within:\n24 hours for critical failures impacting operations\n72 hours for non-critical issues\nExclusions\nThe warranty shall not apply to failures caused by:\nImproper operation by Government personnel\nUnauthorized modifications\nConditions outside normal operating parameters\nDocumentation\nContractor shall provide written warranty documentation upon installation completion\nWarranty start date shall be the date of final acceptance and return to service\nFailure Impact Clause (Recommended for VA)\nIf refractory failure occurs during the warranty period and results in:\nAir Handling Unit outage\nImpact on patient care\nThe contractor shall:\nProvide priority response and repair\nCoordinate with VA staff to minimize downtime\nDELIVERABLES\nFully restored AHU system\nAir Handling Unit returned to safe and efficient operation\n\nComplete documentation package\nJUSTIFICATION (Procurement Support)\nRefurbishment of selected Air Handling Units will result in improved Energy savings, Air Quality, meet NFPA and ASHRAE requirements and allow continuous operation of conditioned air to affected spaces until replacement projects can be executed.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding\nto this sources sought announcement. This notice shall not be construed as a commitment by the\nGovernment to issue a solicitation or ultimately award a contract, nor does it restrict the Government\nto a particular acquisition approach. The Government will in no way be bound to this information if any\nsolicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service\nDisabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran\nOwned Small Business responses, an alternate set-aside or full and open competition may be\ndetermined. No sub-contracting opportunity is anticipated.\nThe North American Classification System (NAICS) code for this acquisition is 238220 Plumbing, Heating, and Air-Conditioning Contractors ($19 M).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal\nGovernment must be registered in the System for Award Management (SAM) at www.sam.gov.\nAdditionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses\nmust be registered with U.S. Small Business Administration (SBA) located at\nhttp://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Shania.kimbrough@va.gov. Telephone\nresponses will not be accepted.\nResponses must be received no later than 08/12/2025 15:00 PM CST.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24926Q0345","place_of_performance":{"zip":"37129","city":{"name":"Murfreesboro"},"state":{"name":"TN"},"street":"Department of Veterans Affairs Alvin C. York VA Medical Center","street2":"3400 Lebanon Pike"},"product_service_code":"J041"}],"due_at":"2026-08-12T20:00:00Z","due_date":"2026-08-12","closes_at":"2026-08-12T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T08:44:04.547541Z","principal_notice_id":"a3e0388f5f0d4c39be6f85293280caf0","description":{"text":"This is a sources sought announcement only. It is neither a solicitation announcement nor a request for\nproposals or quotes and does not obligate the Government to award a contract. Responses in this\nsources sought notice must be in writing. The purpose of this sources sought announcement is for\nmarket research to make appropriate acquisition decisions and to gain knowledge of potential\nbusinesses interested and capable of providing the services described below.\n\nSTATEMENT OF WORK\nDepartment of Veterans Affairs\nTVHS, Alvin C York Campus\nRefurbish Air Handling Units\nPURPOSE\nThe purpose of this contract is to provide all labor, materials, supervision, tools, and equipment necessary to inspect, clean, conduct coil restoration, refurbish, and seal floors, walls, and blowers to meet NFPA 90A requirements on nine (9) Air Handling Units (AHU s) at the historic York Campus of the VA Tennessee Valley Healthcare System, 3400 Lebanon Pike, Murfreesboro, TN 37129 in accordance with the SOW, specifications, drawings and manufacturer recommendations.\nEQUIPMENT DESCRIPTION\nThe work under this contract applies to the following Air Handling Units:\nAHU-14 (Bldg 117 Main Roof)\nAHU-16 (Bldg 3)\nAHU-17 (Bldg 3)\nAHU-27 (Bldg 10 Ground Floor)\nAHU-28 (Bldg 10)\nAHU-29 (Bldg 11 MR G09)\nAHU-29B (Bldg 2)\nAHU-10 (Bldg 2)\nAHU-15 (Bldg 120)\nThe contractor shall be familiar with Cleaver-Brooks firetube boiler refractory systems, including burner throat, furnace, rear door, and turnaround areas.\nSCOPE OF WORK\nInspection & Assessment\nAging Mechanical Equipment\nStanding water\nRust/Corrosion of condensate pans and floors\nWater leaks\nCoil condition\nFire Code Compliance\nCoordinate with customer to determine best times/methods to de-energize AHU s.\nDemolition & Removal\nInspect AHU s units:\nClean and prepare all surfaces that will be addressed by the contractor including removal of non-compliant coatings and foams\n\nDispose of materials per VA, OSHA, and EPA regulations\nProtect motors, fans, ductwork, sensors, UV lights and coils from damage\n\nInstallation and New Work\nCoil Restoration on all coils\nMeasure pressure drop (PD) as allowable\nUse environmentally friendly probiotic foam\nSanitize coils\nRepeat probiotic application and sanitize\nRemeasure AHU PD\nB Install SealTech system on floors, walls, blowers:\nReinforce compromised floors with steel as needed to restore structure to the floors\nSealTech Epoxy (self-leveling) at 3/16 nominal thickness and 6 up walls throughout all chamber floors and condensate pans\nApply Fire Barrier\nApply Antimicrobial Topcoat over all fire barriers\nApply Multi-acrylic, corrosion resistant, antimicrobial coating (MVS) on walls, ceiling, fan housing and structural steel throughout areas addressed with CPR-SL (does not include AHU-14)\nIsolate AHU by sealing off adjacent ductwork\n\nTesting & Commissioning\nA Confirm proper operation of existing CFM, drains, and traps prior to re-commissioning\nGenerate detailed Installation Report, which includes results from PD reading and ATP Testing\nPERFORMANCE REQUIREMENTS\nAll work shall comply with:\nNFPA standards\nASHRAE standards\nOSHA safety regulations\nVA Engineering and Environment of Care requirements\nWork shall maintain continuity of conditioned air for patient care operations\nSCHEDULING & OUTAGE COORDINATION\n\nWork shall be scheduled during approved outage window from 8 am- 4 pm during week workdays\nContractor shall:\nMinimize impact on facility by conducting installation during nights and weeks (when required)\nProvide adequate staffing for critical timelines\nCoordinate Engineering and Maintenance and Operations (M&O)\nSUBMITTALS\nContractor shall provide:\nMaterial specifications (OEM-compliant)\nSafety plan (LOTO, confined space, hot work)\nWork schedule and outage plan\nInspection and deficiency report\nFinal completion and commissioning report\nSAFETY REQUIREMENTS\nComply with VA Lockout/Tagout (LOTO) procedures (if required)\nFollow confined space entry protocols\nUse required PPE (respiratory, thermal, arc-flash as applicable)\nImplement fire watch during hot work\nQUALITY ASSURANCE\nA Contractor must:\nHave minimum 5 years experience with air handling unit refurbishments\nAll work subject to inspection by VA Engineering Service\nWARRANTY\nThe contractor shall provide a minimum ten (10) year warranty from the date of final acceptance by VA Engineering Service.\nCoverage\nThe warranty shall include:\nAll refractory materials installed\nAll labor and workmanship\nAnchoring systems and insulation components\n\nContractor Responsibility\nA The contractor shall repair or replace, at no additional cost to the Government, any defective:\nMaterials\nInstallation\nWorkmanship\nB Corrections shall be completed within a reasonable timeframe as determined by the Contracting Officer and Engineering Service.\nResponse Time\nContractor shall respond to warranty issues within:\n24 hours for critical failures impacting operations\n72 hours for non-critical issues\nExclusions\nThe warranty shall not apply to failures caused by:\nImproper operation by Government personnel\nUnauthorized modifications\nConditions outside normal operating parameters\nDocumentation\nContractor shall provide written warranty documentation upon installation completion\nWarranty start date shall be the date of final acceptance and return to service\nFailure Impact Clause (Recommended for VA)\nIf refractory failure occurs during the warranty period and results in:\nAir Handling Unit outage\nImpact on patient care\nThe contractor shall:\nProvide priority response and repair\nCoordinate with VA staff to minimize downtime\nDELIVERABLES\nFully restored AHU system\nAir Handling Unit returned to safe and efficient operation\n\nComplete documentation package\nJUSTIFICATION (Procurement Support)\nRefurbishment of selected Air Handling Units will result in improved Energy savings, Air Quality, meet NFPA and ASHRAE requirements and allow continuous operation of conditioned air to affected spaces until replacement projects can be executed.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding\nto this sources sought announcement. This notice shall not be construed as a commitment by the\nGovernment to issue a solicitation or ultimately award a contract, nor does it restrict the Government\nto a particular acquisition approach. The Government will in no way be bound to this information if any\nsolicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service\nDisabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran\nOwned Small Business responses, an alternate set-aside or full and open competition may be\ndetermined. No sub-contracting opportunity is anticipated.\nThe North American Classification System (NAICS) code for this acquisition is 238220 Plumbing, Heating, and Air-Conditioning Contractors ($19 M).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal\nGovernment must be registered in the System for Award Management (SAM) at www.sam.gov.\nAdditionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses\nmust be registered with U.S. Small Business Administration (SBA) located at\nhttp://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Shania.kimbrough@va.gov. Telephone\nresponses will not be accepted.\nResponses must be received no later than 08/12/2025 15:00 PM CST.","html":"This is a sources sought announcement only. It is neither a solicitation announcement nor a request for\nproposals or quotes and does not obligate the Government to award a contract. Responses in this\nsources sought notice must be in writing. The purpose of this sources sought announcement is for\nmarket research to make appropriate acquisition decisions and to gain knowledge of potential\nbusinesses interested and capable of providing the services described below.\n\n\n\nSTATEMENT OF WORK\nDepartment of Veterans Affairs\nTVHS, Alvin C York Campus\nRefurbish Air Handling Units\nPURPOSE\nThe purpose of this contract is to provide all labor, materials, supervision, tools, and equipment necessary to inspect, clean, conduct coil restoration, refurbish, and seal floors, walls, and blowers to meet NFPA 90A requirements on nine (9) Air Handling Units (AHU s) at the historic York Campus of the VA Tennessee Valley Healthcare System, 3400 Lebanon Pike, Murfreesboro, TN 37129 in accordance with the SOW, specifications, drawings and manufacturer recommendations.\nEQUIPMENT DESCRIPTION\nThe work under this contract applies to the following Air Handling Units:\nAHU-14 (Bldg 117 Main Roof)\nAHU-16 (Bldg 3)\nAHU-17 (Bldg 3)\nAHU-27 (Bldg 10 Ground Floor)\nAHU-28 (Bldg 10)\nAHU-29 (Bldg 11 MR G09)\nAHU-29B (Bldg 2)\nAHU-10 (Bldg 2)\nAHU-15 (Bldg 120)\nThe contractor shall be familiar with Cleaver-Brooks firetube boiler refractory systems, including burner throat, furnace, rear door, and turnaround areas.\nSCOPE OF WORK\nInspection & Assessment\nAging Mechanical Equipment\nStanding water\nRust/Corrosion of condensate pans and floors\nWater leaks\nCoil condition\nFire Code Compliance\nCoordinate with customer to determine best times/methods to de-energize AHU s.\nDemolition & Removal\nInspect AHU s units:\nClean and prepare all surfaces that will be addressed by the contractor including removal of non-compliant coatings and foams\n\nDispose of materials per VA, OSHA, and EPA regulations\nProtect motors, fans, ductwork, sensors, UV lights and coils from damage\n\n\nInstallation and New Work\nCoil Restoration on all coils\nMeasure pressure drop (PD) as allowable\nUse environmentally friendly probiotic foam\nSanitize coils\nRepeat probiotic application and sanitize\nRemeasure AHU PD\nB Install SealTech system on floors, walls, blowers:\nReinforce compromised floors with steel as needed to restore structure to the floors\nSealTech Epoxy (self-leveling) at 3/16  nominal thickness and 6  up walls throughout all chamber floors and condensate pans\nApply Fire Barrier\nApply  Antimicrobial Topcoat over all fire barriers\nApply Multi-acrylic, corrosion resistant, antimicrobial coating (MVS) on walls, ceiling, fan housing and structural steel throughout areas addressed with CPR-SL (does not include AHU-14)\nIsolate AHU by sealing off adjacent ductwork\n\nTesting & Commissioning\nA Confirm proper operation of existing CFM, drains, and traps prior to re-commissioning\nGenerate detailed Installation Report, which includes results from PD reading and ATP Testing\nPERFORMANCE REQUIREMENTS\nAll work shall comply with:\nNFPA standards\nASHRAE standards\nOSHA safety regulations\nVA Engineering and Environment of Care requirements\nWork shall maintain continuity of conditioned air for patient care operations\nSCHEDULING & OUTAGE COORDINATION\n\nWork shall be scheduled during approved outage window from 8 am- 4 pm during week workdays\nContractor shall:\nMinimize impact on facility by conducting installation during nights and weeks (when required)\nProvide adequate staffing for critical timelines\nCoordinate Engineering and Maintenance and Operations (M&O)\nSUBMITTALS\nContractor shall provide:\nMaterial specifications (OEM-compliant)\nSafety plan (LOTO, confined space, hot work)\nWork schedule and outage plan\nInspection and deficiency report\nFinal completion and commissioning report\nSAFETY REQUIREMENTS\nComply with VA Lockout/Tagout (LOTO) procedures (if required)\nFollow confined space entry protocols\nUse required PPE (respiratory, thermal, arc-flash as applicable)\nImplement fire watch during hot work\nQUALITY ASSURANCE\nA Contractor must:\nHave minimum 5 years  experience with air handling unit refurbishments\nAll work subject to inspection by VA Engineering Service\nWARRANTY\nThe contractor shall provide a minimum ten (10) year warranty from the date of final acceptance by VA Engineering Service.\nCoverage\nThe warranty shall include:\nAll refractory materials installed\nAll labor and workmanship\nAnchoring systems and insulation components\n\nContractor Responsibility\nA           The contractor shall repair or replace, at no additional cost to the Government, any defective:\nMaterials\nInstallation\nWorkmanship\nB            Corrections shall be completed within a reasonable timeframe as determined by the Contracting    Officer and Engineering Service.\nResponse Time\nContractor shall respond to warranty issues within:\n24 hours for critical failures impacting operations\n72 hours for non-critical issues\nExclusions\nThe warranty shall not apply to failures caused by:\nImproper operation by Government personnel\nUnauthorized modifications\nConditions outside normal operating parameters\nDocumentation\nContractor shall provide written warranty documentation upon installation completion\nWarranty start date shall be the date of final acceptance and return to service\nFailure Impact Clause (Recommended for VA)\nIf refractory failure occurs during the warranty period and results in:\nAir Handling Unit outage\nImpact on patient care \nThe contractor shall:\nProvide priority response and repair\nCoordinate with VA staff to minimize downtime\nDELIVERABLES\nFully restored AHU system\nAir Handling Unit returned to safe and efficient operation\n\nComplete documentation package\nJUSTIFICATION (Procurement Support)\nRefurbishment of selected Air Handling Units will result in improved Energy savings, Air Quality, meet NFPA and ASHRAE requirements and allow continuous operation of conditioned air to affected spaces until replacement projects can be executed.\n\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding\nto this sources sought announcement. This notice shall not be construed as a commitment by the\nGovernment to issue a solicitation or ultimately award a contract, nor does it restrict the Government\nto a particular acquisition approach. The Government will in no way be bound to this information if any\nsolicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service\nDisabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran\nOwned Small Business responses, an alternate set-aside or full and open competition may be\ndetermined. No sub-contracting opportunity is anticipated.\nThe North American Classification System (NAICS) code for this acquisition is 238220   Plumbing, Heating, and Air-Conditioning Contractors ($19 M).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal\nGovernment must be registered in the System for Award Management (SAM) at www.sam.gov.\nAdditionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses\nmust be registered with U.S. Small Business Administration (SBA) located at\nhttp://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Shania.kimbrough@va.gov. Telephone\nresponses will not be accepted.\nResponses must be received no later than 08/12/2025 15:00 PM CST.","origin":"detail"},"contacts":[{"name":"Shania Kimbrough","role":"primary","email":"shania.kimbrough@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"37129","city":{"name":"Murfreesboro"},"state":{"name":"TN"},"street":"Department of Veterans Affairs Alvin C. York VA Medical Center","street2":"3400 Lebanon Pike"},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"d00f4e3a888847e6ace756dd96d35f53","name":"36C24926Q0345.docx","kind":"file","mime_type":".docx","size_bytes":34559,"posted_at":"2026-08-05T15:44:03.370Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d00f4e3a888847e6ace756dd96d35f53/download","mirrored":false}],"awards":[],"related":[{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927B0001","latest_notice_id":"3505c1f7e0584df499030ca75a30294e","title":"R602--Medical Courier Services","solicitation_number":"36C24927B0001","notice_type":"p","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-10-16","notices":1,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"492110","psc":"R602","set_aside":"SDVOSBC","state":"KY","county":"21111","county_name":"Jefferson County","city":"2148000","city_name":"Louisville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-17T03:49:26.118050Z"},{"key":"36C24927Q0014","latest_notice_id":"e3fccfa4b53f4e26947a8776f1a55af3","title":"R614--Tennessee Valley Healthcare Services Document Destruction Shredding Services Base plus 4 year contract","solicitation_number":"36C24927Q0014","notice_type":"o","first_type":"p","first_posted":"2026-10-15","last_posted":"2026-11-23","notices":6,"due_at":"2026-12-02T16:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"561990","psc":"R614","set_aside":"SDVOSBC","state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24927R0021","latest_notice_id":"74731079f9214f979cc1b669d71e504a","title":"Z1DA--Design Building (DB) 626-27-504 MHEOCC Compliance TVHS VAMC (Nashville Campus)","solicitation_number":"36C24927R0021","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24927B0002","latest_notice_id":"d4fbb4ac5a81458a955b193f1cef4be0","title":"Z2LZ--626-25-104 Garage Suicide Protection","solicitation_number":"36C24927B0002","notice_type":"o","first_type":"p","first_posted":"2026-10-13","last_posted":"2026-11-16","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z2LZ","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open":[{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":59,"indexable":false}