{"canonical":"https://sealedbidder.com/opportunities/36c24925q0351","key":"36C24925Q0351","url":"https://sealedbidder.com/opportunities/36c24925q0351","title":"6515--Steam Sterilizer for James H. Quillen VA Medical Center","solicitation_number":"36C24925Q0351","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-09T15:00:00Z","first_posted":"2025-06-30","last_posted":"2025-06-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"339113","psc":"6515","set_aside":null,"place_state":"TN","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"9d3b4bae798740f8b81ade3a628068cb","title":"6515--Steam Sterilizer for James H. Quillen VA Medical Center","solicitation_number":"36C24925Q0351","notice_type":"r","base_type":"r","posted":"2025-06-30","posted_at":"2025-06-30T21:27:54.706Z","due_at":"2025-07-09T15:00:00Z","due_date":"2025-07-09","cancelled":false,"archived":true,"archive_date":"2025-08-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9d3b4bae798740f8b81ade3a628068cb/view","enriched":true,"history":[{"index":3,"title":"6515--Steam Sterilizer for James H. Quillen VA Medical Center","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-30T21:27:54.706Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9d3b4bae798740f8b81ade3a628068cb","solicitation_number":"36C24925Q0351"}]}],"latest_notice_id":"9d3b4bae798740f8b81ade3a628068cb","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-30","posted_at":"2025-06-30T21:27:54.706Z","created_at":"2025-06-30T21:27:52.462Z","modified_at":"2025-08-09T03:55:47.658Z","response_deadline":{"raw":"2025-07-09T10:00:00-05:00","utc":"2025-07-09T15:00:00Z","date":"2025-07-09","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9d3b4bae798740f8b81ade3a628068cb/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Steam Sterilizer for James H. Quillen VA Medical Center","agency":{"office":{"code":"36C249","name":"249-NETWORK CONTRACT OFFICE 9 (36C249)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"organization_id":"100163849","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Steam Sterilizer for James H. Quillen VA Medical Center","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-30T21:27:54.706Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9d3b4bae798740f8b81ade3a628068cb","solicitation_number":"36C24925Q0351"}],"contacts":[{"name":"Aye A. A. King","role":"primary","email":"adrian.king@va.gov","phone":"(615) 225-2990","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"9d3b4bae798740f8b81ade3a628068cb","lineage_id":"9d3b4bae798740f8b81ade3a628068cb","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T15:58:43.834435787Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4fbd9361d6ee8afae75354c2aa14b413d407510fbb7c3f5cfac1ad2624f86e0b","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-11T15:58:43.834435787Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 7 of 7\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 7\nDESCRIPTION\nThis is a sources sought announcement only. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses in this sources sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the supplies described below.\nThe James H. Quillen VA Medical Center, 809 Lamont Street., Mt. Home, TN   37684 is looking to purchase three steam sterilizers and supporting accessories as listed below. This procurement shall be a brand name or equal that meet or exceed the physical, functional, and performance of listed statement of work outlined below. Contractors shall show clear, compelling, and convincing evidence that all equal to items meet all requirements as outlined in the included salient characteristics and warranty sections, including brand name and model numbers IAW FAR 52.211-6 Brand Name or Equal.\nCLIN\nITEM DESCRIPTION\nQTY\nUOM\n0001\nTrade In Century Sterilizer\n3\nEA\n0002\nDeinstallation Medium Sterilizer\n3\nEA\n0003\nInstall Loading Cart/Transfer Carriage\n6\nEA\n0004\nInstall Medium Sterilizer\n3\nEA\n0005\nATLAS Transfer Carriage \n26X37.5X48 (AMSCO 400)\n6\nEA\n0006\n48\" ATLAS Loading Car\n6\nEA\n0007\nAMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed 1 Wall Lh Steam\n3\nEA\n\n \nSALIENT CHARACTERISTICS\nSalient Characteristics to apply to all Steam Sterilizers\nThree AMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed, 1-Wall 480v\nHigh capacity chamber that has been validated to sterilize up to 12-25lb instrument trays.\n12 programmable cycles include Prevac 4+1, Gravity and Liquids.Cycle names are customizable.\nThe chamber is constructed of solid 316L stainless steel and carries warranty.\nThe pressure vessel has a full jacket design to minimize the formation of excess condensation on the chamber interior. \nSteam activated gasket requires no lubrication and is warranted.\nThe enhanced display is located at an ergonomic height and features a large cycle countdown visible from 15 feet away.\nSystem operation can be continuously monitored with STERIS Preconnect remote service monitoring.\nAMSCO 400 Medium Steam Sterilizers\nPrevacuum\nLH\nRecessed\nExternal Supplied Steam (Facility Steam/Stand-Alone Generator)\nInstall Medium Sterilizer\nAll necessary labor and materials required to uncrate, set in place and assemble.\nInstall Loading Cart/Transfer Carriage\nAll necessary labor (non union) and materials required to uncrate, set in place and assemble.\nDeinstallation   Medium Sterilizers\nMake all necessary utility disconnections, remove and transport equipment to a predetermined location within same customer facility for pickup or disposal.\nTrade In Century Sterilizer\nFast-Operating, low effort manual door lock mechanism\nHinged door models allows doors to be locked or unlocked using a single 30-degree handle motion.\nTouch Sensitive screen with 30 line x 40 character display area.\nHelp screen for programming and troubleshooting alarm conditions.\nAutomatic check of control program and cycle data maintains process integrity.\nSoftware Calibration is performed in service mode using external or internal temperature and pressure sources\nControl System provides a printed record of all calibration data for verification.\nSteam purge feature is provided to assist in air removal and preheat the load.\nLighted DIN connectors are installed on all steam, water and exhaust valves for reliability and ease of maintenance.\nUTILITIES CONSERVATION FEATURES\nVacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption.\nResistance Temperature Detectors (RTD) are installed for sterilizer temperature control.\nDual element camber drain line RTD senses and controls temperature variations within sterilizer chamber.\nDedicated RTD provides jacket space temperature control.\nElectronic water saving control includes an RTD to control water quantity used in condensing chamber steam exhaust.\nAutomatic utilities start-up/shutdown permits utilities conservation.\nShutdown may be programmed to activate at a specific time of day. When used, utilities control automatically shuts off utility valves, conserving steam and water.\nSterilizer utilities can be restarted automatically or manually. Different daily shutdown and restart times can be programmed. \nInsulation, on inch thick, asbestos-free spin glass (rated at 500 degrees Fahrenheit [260 degrees Celsius] continuous) encompasses the exterior of sterilizer vessel and is sealed in an oil and water resistant outer jacket.\nOperator Interface control panel consists of a touch screen and a quiet and reliable thermal printer located at sterilizer s operating end (OE   loading or non-sterile side).\nTouch-Sensitive Screen features a multi color, touchscreen graphics display\nSterilizer is operated by pressing touch sensitive areas on display (touch pads).\nAppropriate touch pads, operator prompts and status messages necessary for sterilizer operation appear on display as needed.\nDisplay also indicates any alarm conditions either in or out of cycle.\nThermal printer high resolution (8 dot/mm) thermal printer is fast and quiet, printing 25 lines/minute on industrial grade thermal paper. \nPrintout has a guaranteed shelf-life of 25 years and is resistant to exposure from steam, alcohol, UV and visible light, oil, heat and water.\nTime Display and Printout Units AM/PM or 24-hour notation\nAccess Code requires entry of a four digit access code to change cycle values or change operating parameters.\nAudible Signals are adjustable. Touch pad and end of cycle signals can be adjusted to low, medium, high or off. Alarm signals can be adjusted to low, medium, high but cannot be turned off.\nPrint Format allows selection of full or condensed cycle printout.\nTemperature Display and Printout Units are Fahrenheit or Celsius. Temperature is set, displayed controlled and printed to the nearest degree.\nRecalibration is not required when changing temperature unites. \nPressure/Vacuum Display and Printout is psig/InHg or bar. Recalibration is not required when changing pressure units. \nSAFTEY FEATURES\nControl lockout switch prevents cycle from starting until limit switch signal is received. If signal is lost during cycle, alarm activates, cycle aborts and chamber safely vents controlled exhaust.\nChamber float switch activates alarm, abort cycle and safely vent chamber if detecting excessive condensation.\nPressure relief valve releases pressure buildup in chamber if approaching or reaching rated pressure.\nPower door safety feature causes door movement to stop if sliding door encounters an obstruction.\nCONSTRUCTION\nShell Assembly\nFormed from two fabricated Type 316L stainless steel shells, welded one within the other. \nType 316L stainless steel end frame(s) is welded to the door end. \nOn single door units, the back of the chamber is fitted with a welded 316L stainless steel dished head.\nSterilizer vessel is ASME rated at 45 psig and insulated.\nVessel includes one 1  -NPT chamber port for Customer use.\nSteam-supply opening inside chamber is shielded by a stainless-steel baffle.\nChamber door(s)\nDoor is constructed of Type 316L stainless steel.\nDuring operation, door is sealed by steam-activated door seal. Door seal is constructed of long-life rubber compound.\nWhen cycle is complete, seal retracts (under vacuum) into machined groove in end frame.\nLong-life proximity switch detects if door is closed, or locking plates are engaged. An additional seal pressure switch prevents starting a cycle if door is not sealed. \nHinged door sterilizer is equipped with a solenoid door lock.\nHorizontal sliding door units are provided with a mechanically locking door assemble. Locking assemblies prevent door from opening as long as seal is intact, energized and chamber is pressurized at 2 psi or more. \nThe sterilizer door is fitted with a stainless steel panel that insulates operator from chamber end frame, reducing chances of accidental contact with hot metal surfaces.\nChamber Drain System\nDesigned to prevent sterilizer effluent from entering water supply system and chamber. \nAn automatic system of a stainless steel plate type condenser, converts chamber steam to condensate, disposing condensate to waste.\nCooling water flow is regulated by waste line (RTD), minimizing water usage.\nWater supply shut off valve is located in unit s recessed area.\nVacuum System\nVacuum pump reduces chamber pressure during the prevacuum conditioning and drying phases.\nFollowing the drying phase, chamber vacuum, is relived to atmospheric pressure by admitting air through a bacteria-retentive filter.\nSteam source\nSterilizer are piped, valved and trapped to receive building supplied steam at 50 to 80 psig, dynamic.\nSteam piping is brass and includes a shut-off valve, steam strainer and pressure regulator.\nPiping\nAll piping connections terminate within confines of sterilizer frame and are accessible from front, left side.\nSolenoid valves with DIN connectors simplify sterilizer piping and can be serviced individually.\nManual Shut Off Valves are pressure rated at 125 psig (8.62 bar) for saturated steam. Valve handles are heat insulated.\nSterilizers are compatible with Censitrac instrument tracking system. \n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought announcement. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. \nThe VA is mandated by Public Law 109-461 to consider a total set-aside for Service Disabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran Owned Small Business responses, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 339113 (800 employees). \nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses must be registered with U.S. Small Business Administration (SBA) located at http://veterans.certify.sba.gov. \nResponses to this notice shall be submitted via email to Adrian.king@va.gov. Telephone responses will not be accepted. Questions must be submitted no later than 07/07/2025 10:00 AM Central Standard Time (CST). Responses must be received no later than 07/09/2025 10:00 AM CST.","text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 7 of 7\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 7\nDESCRIPTION\nThis is a sources sought announcement only. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses in this sources sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the supplies described below.\nThe James H. Quillen VA Medical Center, 809 Lamont Street., Mt. Home, TN 37684 is looking to purchase three steam sterilizers and supporting accessories as listed below. This procurement shall be a brand name or equal that meet or exceed the physical, functional, and performance of listed statement of work outlined below. Contractors shall show clear, compelling, and convincing evidence that all equal to items meet all requirements as outlined in the included salient characteristics and warranty sections, including brand name and model numbers IAW FAR 52.211-6 Brand Name or Equal.\nCLIN\nITEM DESCRIPTION\nQTY\nUOM\n0001\nTrade In Century Sterilizer\n3\nEA\n0002\nDeinstallation Medium Sterilizer\n3\nEA\n0003\nInstall Loading Cart/Transfer Carriage\n6\nEA\n0004\nInstall Medium Sterilizer\n3\nEA\n0005\nATLAS Transfer Carriage\n26X37.5X48 (AMSCO 400)\n6\nEA\n0006\n48\" ATLAS Loading Car\n6\nEA\n0007\nAMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed 1 Wall Lh Steam\n3\nEA\n\nSALIENT CHARACTERISTICS\nSalient Characteristics to apply to all Steam Sterilizers\nThree AMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed, 1-Wall 480v\nHigh capacity chamber that has been validated to sterilize up to 12-25lb instrument trays.\n12 programmable cycles include Prevac 4+1, Gravity and Liquids.Cycle names are customizable.\nThe chamber is constructed of solid 316L stainless steel and carries warranty.\nThe pressure vessel has a full jacket design to minimize the formation of excess condensation on the chamber interior.\nSteam activated gasket requires no lubrication and is warranted.\nThe enhanced display is located at an ergonomic height and features a large cycle countdown visible from 15 feet away.\nSystem operation can be continuously monitored with STERIS Preconnect remote service monitoring.\nAMSCO 400 Medium Steam Sterilizers\nPrevacuum\nLH\nRecessed\nExternal Supplied Steam (Facility Steam/Stand-Alone Generator)\nInstall Medium Sterilizer\nAll necessary labor and materials required to uncrate, set in place and assemble.\nInstall Loading Cart/Transfer Carriage\nAll necessary labor (non union) and materials required to uncrate, set in place and assemble.\nDeinstallation Medium Sterilizers\nMake all necessary utility disconnections, remove and transport equipment to a predetermined location within same customer facility for pickup or disposal.\nTrade In Century Sterilizer\nFast-Operating, low effort manual door lock mechanism\nHinged door models allows doors to be locked or unlocked using a single 30-degree handle motion.\nTouch Sensitive screen with 30 line x 40 character display area.\nHelp screen for programming and troubleshooting alarm conditions.\nAutomatic check of control program and cycle data maintains process integrity.\nSoftware Calibration is performed in service mode using external or internal temperature and pressure sources\nControl System provides a printed record of all calibration data for verification.\nSteam purge feature is provided to assist in air removal and preheat the load.\nLighted DIN connectors are installed on all steam, water and exhaust valves for reliability and ease of maintenance.\nUTILITIES CONSERVATION FEATURES\nVacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption.\nResistance Temperature Detectors (RTD) are installed for sterilizer temperature control.\nDual element camber drain line RTD senses and controls temperature variations within sterilizer chamber.\nDedicated RTD provides jacket space temperature control.\nElectronic water saving control includes an RTD to control water quantity used in condensing chamber steam exhaust.\nAutomatic utilities start-up/shutdown permits utilities conservation.\nShutdown may be programmed to activate at a specific time of day. When used, utilities control automatically shuts off utility valves, conserving steam and water.\nSterilizer utilities can be restarted automatically or manually. Different daily shutdown and restart times can be programmed.\nInsulation, on inch thick, asbestos-free spin glass (rated at 500 degrees Fahrenheit [260 degrees Celsius] continuous) encompasses the exterior of sterilizer vessel and is sealed in an oil and water resistant outer jacket.\nOperator Interface control panel consists of a touch screen and a quiet and reliable thermal printer located at sterilizer s operating end (OE loading or non-sterile side).\nTouch-Sensitive Screen features a multi color, touchscreen graphics display\nSterilizer is operated by pressing touch sensitive areas on display (touch pads).\nAppropriate touch pads, operator prompts and status messages necessary for sterilizer operation appear on display as needed.\nDisplay also indicates any alarm conditions either in or out of cycle.\nThermal printer high resolution (8 dot/mm) thermal printer is fast and quiet, printing 25 lines/minute on industrial grade thermal paper.\nPrintout has a guaranteed shelf-life of 25 years and is resistant to exposure from steam, alcohol, UV and visible light, oil, heat and water.\nTime Display and Printout Units AM/PM or 24-hour notation\nAccess Code requires entry of a four digit access code to change cycle values or change operating parameters.\nAudible Signals are adjustable. Touch pad and end of cycle signals can be adjusted to low, medium, high or off. Alarm signals can be adjusted to low, medium, high but cannot be turned off.\nPrint Format allows selection of full or condensed cycle printout.\nTemperature Display and Printout Units are Fahrenheit or Celsius. Temperature is set, displayed controlled and printed to the nearest degree.\nRecalibration is not required when changing temperature unites.\nPressure/Vacuum Display and Printout is psig/InHg or bar. Recalibration is not required when changing pressure units.\nSAFTEY FEATURES\nControl lockout switch prevents cycle from starting until limit switch signal is received. If signal is lost during cycle, alarm activates, cycle aborts and chamber safely vents controlled exhaust.\nChamber float switch activates alarm, abort cycle and safely vent chamber if detecting excessive condensation.\nPressure relief valve releases pressure buildup in chamber if approaching or reaching rated pressure.\nPower door safety feature causes door movement to stop if sliding door encounters an obstruction.\nCONSTRUCTION\nShell Assembly\nFormed from two fabricated Type 316L stainless steel shells, welded one within the other.\nType 316L stainless steel end frame(s) is welded to the door end.\nOn single door units, the back of the chamber is fitted with a welded 316L stainless steel dished head.\nSterilizer vessel is ASME rated at 45 psig and insulated.\nVessel includes one 1 -NPT chamber port for Customer use.\nSteam-supply opening inside chamber is shielded by a stainless-steel baffle.\nChamber door(s)\nDoor is constructed of Type 316L stainless steel.\nDuring operation, door is sealed by steam-activated door seal. Door seal is constructed of long-life rubber compound.\nWhen cycle is complete, seal retracts (under vacuum) into machined groove in end frame.\nLong-life proximity switch detects if door is closed, or locking plates are engaged. An additional seal pressure switch prevents starting a cycle if door is not sealed.\nHinged door sterilizer is equipped with a solenoid door lock.\nHorizontal sliding door units are provided with a mechanically locking door assemble. Locking assemblies prevent door from opening as long as seal is intact, energized and chamber is pressurized at 2 psi or more.\nThe sterilizer door is fitted with a stainless steel panel that insulates operator from chamber end frame, reducing chances of accidental contact with hot metal surfaces.\nChamber Drain System\nDesigned to prevent sterilizer effluent from entering water supply system and chamber.\nAn automatic system of a stainless steel plate type condenser, converts chamber steam to condensate, disposing condensate to waste.\nCooling water flow is regulated by waste line (RTD), minimizing water usage.\nWater supply shut off valve is located in unit s recessed area.\nVacuum System\nVacuum pump reduces chamber pressure during the prevacuum conditioning and drying phases.\nFollowing the drying phase, chamber vacuum, is relived to atmospheric pressure by admitting air through a bacteria-retentive filter.\nSteam source\nSterilizer are piped, valved and trapped to receive building supplied steam at 50 to 80 psig, dynamic.\nSteam piping is brass and includes a shut-off valve, steam strainer and pressure regulator.\nPiping\nAll piping connections terminate within confines of sterilizer frame and are accessible from front, left side.\nSolenoid valves with DIN connectors simplify sterilizer piping and can be serviced individually.\nManual Shut Off Valves are pressure rated at 125 psig (8.62 bar) for saturated steam. Valve handles are heat insulated.\nSterilizers are compatible with Censitrac instrument tracking system.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought announcement. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.\nThe VA is mandated by Public Law 109-461 to consider a total set-aside for Service Disabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran Owned Small Business responses, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 339113 (800 employees).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses must be registered with U.S. Small Business Administration (SBA) located at http://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Adrian.king@va.gov. Telephone responses will not be accepted. Questions must be submitted no later than 07/07/2025 10:00 AM Central Standard Time (CST). Responses must be received no later than 07/09/2025 10:00 AM CST.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24925Q0351","place_of_performance":{"zip":"37684","city":{"code":"50440","name":"Mountain Home"},"state":{"code":"TN","name":"Tennessee"},"street":"Department of Veterans Affairs James H. Quillen VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"809 Lamont St"},"product_service_code":"6515"}],"due_at":"2025-07-09T15:00:00Z","due_date":"2025-07-09","closes_at":"2025-07-09T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","state":"TN","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-11T16:46:04.463720Z","principal_notice_id":"9d3b4bae798740f8b81ade3a628068cb","description":{"text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 7 of 7\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 7\nDESCRIPTION\nThis is a sources sought announcement only. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses in this sources sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the supplies described below.\nThe James H. Quillen VA Medical Center, 809 Lamont Street., Mt. Home, TN 37684 is looking to purchase three steam sterilizers and supporting accessories as listed below. This procurement shall be a brand name or equal that meet or exceed the physical, functional, and performance of listed statement of work outlined below. Contractors shall show clear, compelling, and convincing evidence that all equal to items meet all requirements as outlined in the included salient characteristics and warranty sections, including brand name and model numbers IAW FAR 52.211-6 Brand Name or Equal.\nCLIN\nITEM DESCRIPTION\nQTY\nUOM\n0001\nTrade In Century Sterilizer\n3\nEA\n0002\nDeinstallation Medium Sterilizer\n3\nEA\n0003\nInstall Loading Cart/Transfer Carriage\n6\nEA\n0004\nInstall Medium Sterilizer\n3\nEA\n0005\nATLAS Transfer Carriage\n26X37.5X48 (AMSCO 400)\n6\nEA\n0006\n48\" ATLAS Loading Car\n6\nEA\n0007\nAMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed 1 Wall Lh Steam\n3\nEA\n\nSALIENT CHARACTERISTICS\nSalient Characteristics to apply to all Steam Sterilizers\nThree AMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed, 1-Wall 480v\nHigh capacity chamber that has been validated to sterilize up to 12-25lb instrument trays.\n12 programmable cycles include Prevac 4+1, Gravity and Liquids.Cycle names are customizable.\nThe chamber is constructed of solid 316L stainless steel and carries warranty.\nThe pressure vessel has a full jacket design to minimize the formation of excess condensation on the chamber interior.\nSteam activated gasket requires no lubrication and is warranted.\nThe enhanced display is located at an ergonomic height and features a large cycle countdown visible from 15 feet away.\nSystem operation can be continuously monitored with STERIS Preconnect remote service monitoring.\nAMSCO 400 Medium Steam Sterilizers\nPrevacuum\nLH\nRecessed\nExternal Supplied Steam (Facility Steam/Stand-Alone Generator)\nInstall Medium Sterilizer\nAll necessary labor and materials required to uncrate, set in place and assemble.\nInstall Loading Cart/Transfer Carriage\nAll necessary labor (non union) and materials required to uncrate, set in place and assemble.\nDeinstallation Medium Sterilizers\nMake all necessary utility disconnections, remove and transport equipment to a predetermined location within same customer facility for pickup or disposal.\nTrade In Century Sterilizer\nFast-Operating, low effort manual door lock mechanism\nHinged door models allows doors to be locked or unlocked using a single 30-degree handle motion.\nTouch Sensitive screen with 30 line x 40 character display area.\nHelp screen for programming and troubleshooting alarm conditions.\nAutomatic check of control program and cycle data maintains process integrity.\nSoftware Calibration is performed in service mode using external or internal temperature and pressure sources\nControl System provides a printed record of all calibration data for verification.\nSteam purge feature is provided to assist in air removal and preheat the load.\nLighted DIN connectors are installed on all steam, water and exhaust valves for reliability and ease of maintenance.\nUTILITIES CONSERVATION FEATURES\nVacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption.\nResistance Temperature Detectors (RTD) are installed for sterilizer temperature control.\nDual element camber drain line RTD senses and controls temperature variations within sterilizer chamber.\nDedicated RTD provides jacket space temperature control.\nElectronic water saving control includes an RTD to control water quantity used in condensing chamber steam exhaust.\nAutomatic utilities start-up/shutdown permits utilities conservation.\nShutdown may be programmed to activate at a specific time of day. When used, utilities control automatically shuts off utility valves, conserving steam and water.\nSterilizer utilities can be restarted automatically or manually. Different daily shutdown and restart times can be programmed.\nInsulation, on inch thick, asbestos-free spin glass (rated at 500 degrees Fahrenheit [260 degrees Celsius] continuous) encompasses the exterior of sterilizer vessel and is sealed in an oil and water resistant outer jacket.\nOperator Interface control panel consists of a touch screen and a quiet and reliable thermal printer located at sterilizer s operating end (OE loading or non-sterile side).\nTouch-Sensitive Screen features a multi color, touchscreen graphics display\nSterilizer is operated by pressing touch sensitive areas on display (touch pads).\nAppropriate touch pads, operator prompts and status messages necessary for sterilizer operation appear on display as needed.\nDisplay also indicates any alarm conditions either in or out of cycle.\nThermal printer high resolution (8 dot/mm) thermal printer is fast and quiet, printing 25 lines/minute on industrial grade thermal paper.\nPrintout has a guaranteed shelf-life of 25 years and is resistant to exposure from steam, alcohol, UV and visible light, oil, heat and water.\nTime Display and Printout Units AM/PM or 24-hour notation\nAccess Code requires entry of a four digit access code to change cycle values or change operating parameters.\nAudible Signals are adjustable. Touch pad and end of cycle signals can be adjusted to low, medium, high or off. Alarm signals can be adjusted to low, medium, high but cannot be turned off.\nPrint Format allows selection of full or condensed cycle printout.\nTemperature Display and Printout Units are Fahrenheit or Celsius. Temperature is set, displayed controlled and printed to the nearest degree.\nRecalibration is not required when changing temperature unites.\nPressure/Vacuum Display and Printout is psig/InHg or bar. Recalibration is not required when changing pressure units.\nSAFTEY FEATURES\nControl lockout switch prevents cycle from starting until limit switch signal is received. If signal is lost during cycle, alarm activates, cycle aborts and chamber safely vents controlled exhaust.\nChamber float switch activates alarm, abort cycle and safely vent chamber if detecting excessive condensation.\nPressure relief valve releases pressure buildup in chamber if approaching or reaching rated pressure.\nPower door safety feature causes door movement to stop if sliding door encounters an obstruction.\nCONSTRUCTION\nShell Assembly\nFormed from two fabricated Type 316L stainless steel shells, welded one within the other.\nType 316L stainless steel end frame(s) is welded to the door end.\nOn single door units, the back of the chamber is fitted with a welded 316L stainless steel dished head.\nSterilizer vessel is ASME rated at 45 psig and insulated.\nVessel includes one 1 -NPT chamber port for Customer use.\nSteam-supply opening inside chamber is shielded by a stainless-steel baffle.\nChamber door(s)\nDoor is constructed of Type 316L stainless steel.\nDuring operation, door is sealed by steam-activated door seal. Door seal is constructed of long-life rubber compound.\nWhen cycle is complete, seal retracts (under vacuum) into machined groove in end frame.\nLong-life proximity switch detects if door is closed, or locking plates are engaged. An additional seal pressure switch prevents starting a cycle if door is not sealed.\nHinged door sterilizer is equipped with a solenoid door lock.\nHorizontal sliding door units are provided with a mechanically locking door assemble. Locking assemblies prevent door from opening as long as seal is intact, energized and chamber is pressurized at 2 psi or more.\nThe sterilizer door is fitted with a stainless steel panel that insulates operator from chamber end frame, reducing chances of accidental contact with hot metal surfaces.\nChamber Drain System\nDesigned to prevent sterilizer effluent from entering water supply system and chamber.\nAn automatic system of a stainless steel plate type condenser, converts chamber steam to condensate, disposing condensate to waste.\nCooling water flow is regulated by waste line (RTD), minimizing water usage.\nWater supply shut off valve is located in unit s recessed area.\nVacuum System\nVacuum pump reduces chamber pressure during the prevacuum conditioning and drying phases.\nFollowing the drying phase, chamber vacuum, is relived to atmospheric pressure by admitting air through a bacteria-retentive filter.\nSteam source\nSterilizer are piped, valved and trapped to receive building supplied steam at 50 to 80 psig, dynamic.\nSteam piping is brass and includes a shut-off valve, steam strainer and pressure regulator.\nPiping\nAll piping connections terminate within confines of sterilizer frame and are accessible from front, left side.\nSolenoid valves with DIN connectors simplify sterilizer piping and can be serviced individually.\nManual Shut Off Valves are pressure rated at 125 psig (8.62 bar) for saturated steam. Valve handles are heat insulated.\nSterilizers are compatible with Censitrac instrument tracking system.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought announcement. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.\nThe VA is mandated by Public Law 109-461 to consider a total set-aside for Service Disabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran Owned Small Business responses, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 339113 (800 employees).\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses must be registered with U.S. Small Business Administration (SBA) located at http://veterans.certify.sba.gov.\nResponses to this notice shall be submitted via email to Adrian.king@va.gov. Telephone responses will not be accepted. Questions must be submitted no later than 07/07/2025 10:00 AM Central Standard Time (CST). Responses must be received no later than 07/09/2025 10:00 AM CST.","html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 7 of 7\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 7\nDESCRIPTION\nThis is a sources sought announcement only. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses in this sources sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the supplies described below.\nThe James H. Quillen VA Medical Center, 809 Lamont Street., Mt. Home, TN   37684 is looking to purchase three steam sterilizers and supporting accessories as listed below. This procurement shall be a brand name or equal that meet or exceed the physical, functional, and performance of listed statement of work outlined below. Contractors shall show clear, compelling, and convincing evidence that all equal to items meet all requirements as outlined in the included salient characteristics and warranty sections, including brand name and model numbers IAW FAR 52.211-6 Brand Name or Equal.\nCLIN\nITEM DESCRIPTION\nQTY\nUOM\n0001\nTrade In Century Sterilizer\n3\nEA\n0002\nDeinstallation Medium Sterilizer\n3\nEA\n0003\nInstall Loading Cart/Transfer Carriage\n6\nEA\n0004\nInstall Medium Sterilizer\n3\nEA\n0005\nATLAS Transfer Carriage \n26X37.5X48 (AMSCO 400)\n6\nEA\n0006\n48\" ATLAS Loading Car\n6\nEA\n0007\nAMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed 1 Wall Lh Steam\n3\nEA\n\n \nSALIENT CHARACTERISTICS\nSalient Characteristics to apply to all Steam Sterilizers\nThree AMSCO 400 26X37.5X48 Prevacuum Single Hinge Recessed, 1-Wall 480v\nHigh capacity chamber that has been validated to sterilize up to 12-25lb instrument trays.\n12 programmable cycles include Prevac 4+1, Gravity and Liquids.Cycle names are customizable.\nThe chamber is constructed of solid 316L stainless steel and carries warranty.\nThe pressure vessel has a full jacket design to minimize the formation of excess condensation on the chamber interior. \nSteam activated gasket requires no lubrication and is warranted.\nThe enhanced display is located at an ergonomic height and features a large cycle countdown visible from 15 feet away.\nSystem operation can be continuously monitored with STERIS Preconnect remote service monitoring.\nAMSCO 400 Medium Steam Sterilizers\nPrevacuum\nLH\nRecessed\nExternal Supplied Steam (Facility Steam/Stand-Alone Generator)\nInstall Medium Sterilizer\nAll necessary labor and materials required to uncrate, set in place and assemble.\nInstall Loading Cart/Transfer Carriage\nAll necessary labor (non union) and materials required to uncrate, set in place and assemble.\nDeinstallation   Medium Sterilizers\nMake all necessary utility disconnections, remove and transport equipment to a predetermined location within same customer facility for pickup or disposal.\nTrade In Century Sterilizer\nFast-Operating, low effort manual door lock mechanism\nHinged door models allows doors to be locked or unlocked using a single 30-degree handle motion.\nTouch Sensitive screen with 30 line x 40 character display area.\nHelp screen for programming and troubleshooting alarm conditions.\nAutomatic check of control program and cycle data maintains process integrity.\nSoftware Calibration is performed in service mode using external or internal temperature and pressure sources\nControl System provides a printed record of all calibration data for verification.\nSteam purge feature is provided to assist in air removal and preheat the load.\nLighted DIN connectors are installed on all steam, water and exhaust valves for reliability and ease of maintenance.\nUTILITIES CONSERVATION FEATURES\nVacuum pump effectively pulls chamber to specified vacuum levels and reduces water consumption.\nResistance Temperature Detectors (RTD) are installed for sterilizer temperature control.\nDual element camber drain line RTD senses and controls temperature variations within sterilizer chamber.\nDedicated RTD provides jacket space temperature control.\nElectronic water saving control includes an RTD to control water quantity used in condensing chamber steam exhaust.\nAutomatic utilities start-up/shutdown permits utilities conservation.\nShutdown may be programmed to activate at a specific time of day. When used, utilities control automatically shuts off utility valves, conserving steam and water.\nSterilizer utilities can be restarted automatically or manually. Different daily shutdown and restart times can be programmed. \nInsulation, on inch thick, asbestos-free spin glass (rated at 500 degrees Fahrenheit [260 degrees Celsius] continuous) encompasses the exterior of sterilizer vessel and is sealed in an oil and water resistant outer jacket.\nOperator Interface control panel consists of a touch screen and a quiet and reliable thermal printer located at sterilizer s operating end (OE   loading or non-sterile side).\nTouch-Sensitive Screen features a multi color, touchscreen graphics display\nSterilizer is operated by pressing touch sensitive areas on display (touch pads).\nAppropriate touch pads, operator prompts and status messages necessary for sterilizer operation appear on display as needed.\nDisplay also indicates any alarm conditions either in or out of cycle.\nThermal printer high resolution (8 dot/mm) thermal printer is fast and quiet, printing 25 lines/minute on industrial grade thermal paper. \nPrintout has a guaranteed shelf-life of 25 years and is resistant to exposure from steam, alcohol, UV and visible light, oil, heat and water.\nTime Display and Printout Units AM/PM or 24-hour notation\nAccess Code requires entry of a four digit access code to change cycle values or change operating parameters.\nAudible Signals are adjustable. Touch pad and end of cycle signals can be adjusted to low, medium, high or off. Alarm signals can be adjusted to low, medium, high but cannot be turned off.\nPrint Format allows selection of full or condensed cycle printout.\nTemperature Display and Printout Units are Fahrenheit or Celsius. Temperature is set, displayed controlled and printed to the nearest degree.\nRecalibration is not required when changing temperature unites. \nPressure/Vacuum Display and Printout is psig/InHg or bar. Recalibration is not required when changing pressure units. \nSAFTEY FEATURES\nControl lockout switch prevents cycle from starting until limit switch signal is received. If signal is lost during cycle, alarm activates, cycle aborts and chamber safely vents controlled exhaust.\nChamber float switch activates alarm, abort cycle and safely vent chamber if detecting excessive condensation.\nPressure relief valve releases pressure buildup in chamber if approaching or reaching rated pressure.\nPower door safety feature causes door movement to stop if sliding door encounters an obstruction.\nCONSTRUCTION\nShell Assembly\nFormed from two fabricated Type 316L stainless steel shells, welded one within the other. \nType 316L stainless steel end frame(s) is welded to the door end. \nOn single door units, the back of the chamber is fitted with a welded 316L stainless steel dished head.\nSterilizer vessel is ASME rated at 45 psig and insulated.\nVessel includes one 1  -NPT chamber port for Customer use.\nSteam-supply opening inside chamber is shielded by a stainless-steel baffle.\nChamber door(s)\nDoor is constructed of Type 316L stainless steel.\nDuring operation, door is sealed by steam-activated door seal. Door seal is constructed of long-life rubber compound.\nWhen cycle is complete, seal retracts (under vacuum) into machined groove in end frame.\nLong-life proximity switch detects if door is closed, or locking plates are engaged. An additional seal pressure switch prevents starting a cycle if door is not sealed. \nHinged door sterilizer is equipped with a solenoid door lock.\nHorizontal sliding door units are provided with a mechanically locking door assemble. Locking assemblies prevent door from opening as long as seal is intact, energized and chamber is pressurized at 2 psi or more. \nThe sterilizer door is fitted with a stainless steel panel that insulates operator from chamber end frame, reducing chances of accidental contact with hot metal surfaces.\nChamber Drain System\nDesigned to prevent sterilizer effluent from entering water supply system and chamber. \nAn automatic system of a stainless steel plate type condenser, converts chamber steam to condensate, disposing condensate to waste.\nCooling water flow is regulated by waste line (RTD), minimizing water usage.\nWater supply shut off valve is located in unit s recessed area.\nVacuum System\nVacuum pump reduces chamber pressure during the prevacuum conditioning and drying phases.\nFollowing the drying phase, chamber vacuum, is relived to atmospheric pressure by admitting air through a bacteria-retentive filter.\nSteam source\nSterilizer are piped, valved and trapped to receive building supplied steam at 50 to 80 psig, dynamic.\nSteam piping is brass and includes a shut-off valve, steam strainer and pressure regulator.\nPiping\nAll piping connections terminate within confines of sterilizer frame and are accessible from front, left side.\nSolenoid valves with DIN connectors simplify sterilizer piping and can be serviced individually.\nManual Shut Off Valves are pressure rated at 125 psig (8.62 bar) for saturated steam. Valve handles are heat insulated.\nSterilizers are compatible with Censitrac instrument tracking system. \n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought announcement. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. \nThe VA is mandated by Public Law 109-461 to consider a total set-aside for Service Disabled Veteran Owned Small Businesses. However, if there are insufficient Service Disabled Veteran Owned Small Business responses, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 339113 (800 employees). \nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses must be registered with U.S. Small Business Administration (SBA) located at http://veterans.certify.sba.gov. \nResponses to this notice shall be submitted via email to Adrian.king@va.gov. Telephone responses will not be accepted. Questions must be submitted no later than 07/07/2025 10:00 AM Central Standard Time (CST). Responses must be received no later than 07/09/2025 10:00 AM CST.","origin":"detail"},"contacts":[{"name":"Aye A. A. King","role":"primary","email":"adrian.king@va.gov","phone":"(615) 225-2990","title":"Contract Specialist"}],"place_of_performance":{"zip":"37684","city":{"code":"50440","name":"Mountain Home"},"state":{"code":"TN","name":"Tennessee"},"street":"Department of Veterans Affairs James H. Quillen VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"809 Lamont St"},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"10a13f8d725d48f89a79861686d6faba","name":"36C24925Q0351.docx","kind":"file","mime_type":".docx","size_bytes":37298,"posted_at":"2025-06-30T21:27:54.706Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/10a13f8d725d48f89a79861686d6faba/download","mirrored":false}],"awards":[],"related":[{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927B0001","latest_notice_id":"3505c1f7e0584df499030ca75a30294e","title":"R602--Medical Courier Services","solicitation_number":"36C24927B0001","notice_type":"p","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-10-16","notices":1,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"492110","psc":"R602","set_aside":"SDVOSBC","state":"KY","county":"21111","county_name":"Jefferson County","city":"2148000","city_name":"Louisville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-17T03:49:26.118050Z"},{"key":"36C24927Q0014","latest_notice_id":"65a1ee030b6a40e682c7f6b349814272","title":"R614--Tennessee Valley Healthcare Services Document Destruction Shredding Services Base plus 4 year contract","solicitation_number":"36C24927Q0014","notice_type":"o","first_type":"p","first_posted":"2026-10-15","last_posted":"2026-11-25","notices":7,"due_at":"2026-12-02T16:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"561990","psc":"R614","set_aside":"SDVOSBC","state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C24927R0021","latest_notice_id":"74731079f9214f979cc1b669d71e504a","title":"Z1DA--Design Building (DB) 626-27-504 MHEOCC Compliance TVHS VAMC (Nashville Campus)","solicitation_number":"36C24927R0021","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24927B0002","latest_notice_id":"d4fbb4ac5a81458a955b193f1cef4be0","title":"Z2LZ--626-25-104 Garage Suicide Protection","solicitation_number":"36C24927B0002","notice_type":"o","first_type":"p","first_posted":"2026-10-13","last_posted":"2026-11-16","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z2LZ","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":20,"indexable":false}