{"canonical":"https://sealedbidder.com/opportunities/36c24925q0182","key":"36C24925Q0182","url":"https://sealedbidder.com/opportunities/36c24925q0182","title":"6515--36C249-25-AP-0528 - Automated Unit Dose Medication Re-packager - Pharmacy","solicitation_number":"36C24925Q0182","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-20T20:00:00Z","first_posted":"2025-03-17","last_posted":"2025-03-17","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"339112","psc":"6515","set_aside":null,"place_state":"TN","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"47149","place_county_name":"Rutherford County","place_city":"4751560","place_city_name":"Murfreesboro","winner":null,"award_amount":null,"publications":[{"notice_id":"dde8d72491c74e43bf7d010f378bb237","title":"6515--36C249-25-AP-0528 - Automated Unit Dose Medication Re-packager - Pharmacy","solicitation_number":"36C24925Q0182","notice_type":"r","base_type":"r","posted":"2025-03-17","posted_at":"2025-03-17T12:18:44.363Z","due_at":"2025-03-20T20:00:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-05-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dde8d72491c74e43bf7d010f378bb237/view","enriched":true,"history":[{"index":3,"title":"6515--36C249-25-AP-0528 - Automated Unit Dose Medication Re-packager - Pharmacy","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-17T12:18:44.363Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"dde8d72491c74e43bf7d010f378bb237","solicitation_number":"36C24925Q0182"}]}],"latest_notice_id":"dde8d72491c74e43bf7d010f378bb237","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-03-17","posted_at":"2025-03-17T12:18:44.363Z","created_at":"2025-03-17T12:18:43.185Z","modified_at":"2025-05-20T03:56:03.496Z","response_deadline":{"raw":"2025-03-20T15:00:00-05:00","utc":"2025-03-20T20:00:00Z","date":"2025-03-20","time":"15:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dde8d72491c74e43bf7d010f378bb237/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--36C249-25-AP-0528 - Automated Unit Dose Medication Re-packager - Pharmacy","agency":{"office":{"code":"36C249","name":"249-NETWORK CONTRACT OFFICE 9 (36C249)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"organization_id":"100163849","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-19","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--36C249-25-AP-0528 - Automated Unit Dose Medication Re-packager - Pharmacy","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-17T12:18:44.363Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"dde8d72491c74e43bf7d010f378bb237","solicitation_number":"36C24925Q0182"}],"contacts":[{"name":"Daymeion Brantley","role":"primary","email":"daymeion.brantley@va.gov","phone":"615.225.3616","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"dde8d72491c74e43bf7d010f378bb237","lineage_id":"dde8d72491c74e43bf7d010f378bb237","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T08:41:59.041137525Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"0f8765a5f8e8d4e3e0bbd62461fd05e86ee91b9ddc862b0a8234d9b169455c04","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T08:41:59.041137525Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This not a request for quotes; the Government is seeking information for market research purposes only. VA Network Contracting Office (NCO) 9 is seeking sources interested and capable of providing the items as described in the attached Product Description. \nThe North American Industry Classification System (NAICS) is 339112   SURGICAL AND MEDICAL INSTRUMENT MANUFACTURING\nThe Service Code (PSC) is 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES\n\nResponses to this notice shall include company/individual name, size status for the above reference NAICS code, a service capability statement, SAM Entity Unique Identifier (EUI), address, point of contact, and examples of similar facilities to which similar items have been provided.\nContractors must provide information on whether they are certified SDVOSB, VOSB, Hub zone, 8(a), women-owned concern. If standard company brochures will be provided as a response to this Source Sought, ensure that additional information tailored to this notice is included.\nThis is not a solicitation for quotes. If a solicitation is issued, it will be announced on the Contract Opportunities website https://sam.gov at a later date, and all interested parties must respond to that solicitation announcement separately from the response to this announcement. \nContractors must be registered in System for Award Management (SAM), see internet site: https://www.sam.gov for information about registration.\nIdentify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.\nDo you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?\nIf you are in GSA, please provide schedule and contract number.\nResponses to this notice must be submitted via email to daymeion.brantley@va.gov. No telephone inquiries will be accepted.\nDISCLAIMER This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought.\nVeterans Affairs, NCO-9, is seeking information for vendors interested and capable of providing items meeting the below saliant characteristics:\n******************************************************\nUnit Dose Packaging Machine:\nSaliant Characteristics:\nThe system will need to have the ability to communicate with VISTA use HL7 messaging.\nPackager will have a touch screen for navigation as an all-in-one, with biometric scanning for user login.\nPackager cannot exceed the following dimensions due to space limitations: 48  Width, 90 Height, 48  Deep. This space has the necessary data and power requirements in pharmacy.  There is not space sufficient in any other location in current pharmacy design.\nPackager must fit through pharmacy door (46  width and 83  height)\nMust have at least 400-canister capacity.\nMust include a special tablet system or STS.\nPackager must have a dual tray system allowing users to  pre-fill  or stage two trays at a time, providing continuous dispensing of non-canister medications.\nThe packaging system must have software features allowing users to use a different National Drug Code (NDC) if the primary NDC for an order has ran out of inventory; to pause a batch during a production run to work on another batch allowing users to come back to the paused batch and pick up where it left off; group or daisy chain canisters together to reduce refill rates for high volume or large pill; skip a medication if unavailable then removing it from the order staging it as separate order when inventory is available; and allow users to separate an order with multiple patients into separate orders at the packager level.\nPackager must have a swappable lower packaging unit for onsite redundancy to eliminate downtime.\nPackaging system will use a clamp and seal system to efficiently seal pre-folded paper with a serrated edge to ensure pouches are produced with less errors and make it easy to access medications.\nPackager must have auto-correcting motor bases preventing jams while dispensing from canisters.\nSystem must have reporting capabilities giving users the ability to check user metrics and run audit reports.\nSystem must have self-calibration canister kits for canisters (ability to modify canisters to fit different shape and size medications without replacing canister).\nSystem must have a set of universal, manually adjustable canisters allowing the pharmacy staff to calibrate canister for new NDC s without the need to swap out canister parts.\nSystem must have automatic canister recognition chip system available, which will enable any canister to be seated in any location in the packager.\nSystem must have the ability to change pouch sizes to fit different sized medications.\nSystem must be able to print custom labels (color included)\nPackages produced from system must be individually packaged and at a minimum contain: drug name, dose, dosage form, lot number, expiration date, and Bar Code Medication Administration (BCMA) compatible barcode/ 2-D printing options.\nSystem must be compatible with Windows 10\nPackage must be most current version of software and/or system.\nSystem must have HL7 interface with pharmacy system Cerner / Vista/ Automated Dispensing Cabinets.\nSystems first year s software licensing is included in initial purchase. \nSystem must have a pouch verification system that can verify label and contents of each packet to improve accuracy and efficiency.\nPouch verification system must be able to produce a cut and rolled group of medications by patient, facility, or hour of administration.\nCompany will provide at minimum 3 days of training on both campuses for staff to be adequately trained.","text":"This not a request for quotes; the Government is seeking information for market research purposes only. VA Network Contracting Office (NCO) 9 is seeking sources interested and capable of providing the items as described in the attached Product Description.\nThe North American Industry Classification System (NAICS) is 339112 SURGICAL AND MEDICAL INSTRUMENT MANUFACTURING\nThe Service Code (PSC) is 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES\n\nResponses to this notice shall include company/individual name, size status for the above reference NAICS code, a service capability statement, SAM Entity Unique Identifier (EUI), address, point of contact, and examples of similar facilities to which similar items have been provided.\nContractors must provide information on whether they are certified SDVOSB, VOSB, Hub zone, 8(a), women-owned concern. If standard company brochures will be provided as a response to this Source Sought, ensure that additional information tailored to this notice is included.\nThis is not a solicitation for quotes. If a solicitation is issued, it will be announced on the Contract Opportunities website https://sam.gov at a later date, and all interested parties must respond to that solicitation announcement separately from the response to this announcement.\nContractors must be registered in System for Award Management (SAM), see internet site: https://www.sam.gov for information about registration.\nIdentify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.\nDo you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?\nIf you are in GSA, please provide schedule and contract number.\nResponses to this notice must be submitted via email to daymeion.brantley@va.gov. No telephone inquiries will be accepted.\nDISCLAIMER This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought.\nVeterans Affairs, NCO-9, is seeking information for vendors interested and capable of providing items meeting the below saliant characteristics:\n******************************************************\nUnit Dose Packaging Machine:\nSaliant Characteristics:\nThe system will need to have the ability to communicate with VISTA use HL7 messaging.\nPackager will have a touch screen for navigation as an all-in-one, with biometric scanning for user login.\nPackager cannot exceed the following dimensions due to space limitations: 48 Width, 90 Height, 48 Deep. This space has the necessary data and power requirements in pharmacy. There is not space sufficient in any other location in current pharmacy design.\nPackager must fit through pharmacy door (46 width and 83 height)\nMust have at least 400-canister capacity.\nMust include a special tablet system or STS.\nPackager must have a dual tray system allowing users to pre-fill or stage two trays at a time, providing continuous dispensing of non-canister medications.\nThe packaging system must have software features allowing users to use a different National Drug Code (NDC) if the primary NDC for an order has ran out of inventory; to pause a batch during a production run to work on another batch allowing users to come back to the paused batch and pick up where it left off; group or daisy chain canisters together to reduce refill rates for high volume or large pill; skip a medication if unavailable then removing it from the order staging it as separate order when inventory is available; and allow users to separate an order with multiple patients into separate orders at the packager level.\nPackager must have a swappable lower packaging unit for onsite redundancy to eliminate downtime.\nPackaging system will use a clamp and seal system to efficiently seal pre-folded paper with a serrated edge to ensure pouches are produced with less errors and make it easy to access medications.\nPackager must have auto-correcting motor bases preventing jams while dispensing from canisters.\nSystem must have reporting capabilities giving users the ability to check user metrics and run audit reports.\nSystem must have self-calibration canister kits for canisters (ability to modify canisters to fit different shape and size medications without replacing canister).\nSystem must have a set of universal, manually adjustable canisters allowing the pharmacy staff to calibrate canister for new NDC s without the need to swap out canister parts.\nSystem must have automatic canister recognition chip system available, which will enable any canister to be seated in any location in the packager.\nSystem must have the ability to change pouch sizes to fit different sized medications.\nSystem must be able to print custom labels (color included)\nPackages produced from system must be individually packaged and at a minimum contain: drug name, dose, dosage form, lot number, expiration date, and Bar Code Medication Administration (BCMA) compatible barcode/ 2-D printing options.\nSystem must be compatible with Windows 10\nPackage must be most current version of software and/or system.\nSystem must have HL7 interface with pharmacy system Cerner / Vista/ Automated Dispensing Cabinets.\nSystems first year s software licensing is included in initial purchase.\nSystem must have a pouch verification system that can verify label and contents of each packet to improve accuracy and efficiency.\nPouch verification system must be able to produce a cut and rolled group of medications by patient, facility, or hour of administration.\nCompany will provide at minimum 3 days of training on both campuses for staff to be adequately trained.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24925Q0182","place_of_performance":{"zip":"37129","city":{"code":"51560","name":"Murfreesboro"},"state":{"code":"TN","name":"Tennessee"},"street":"Alvin C. York VA Medical Center 3400 Lebanon Rd","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2025-03-20T20:00:00Z","due_date":"2025-03-20","closes_at":"2025-03-20T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T08:45:02.113346Z","principal_notice_id":"dde8d72491c74e43bf7d010f378bb237","description":{"text":"This not a request for quotes; the Government is seeking information for market research purposes only. VA Network Contracting Office (NCO) 9 is seeking sources interested and capable of providing the items as described in the attached Product Description.\nThe North American Industry Classification System (NAICS) is 339112 SURGICAL AND MEDICAL INSTRUMENT MANUFACTURING\nThe Service Code (PSC) is 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES\n\nResponses to this notice shall include company/individual name, size status for the above reference NAICS code, a service capability statement, SAM Entity Unique Identifier (EUI), address, point of contact, and examples of similar facilities to which similar items have been provided.\nContractors must provide information on whether they are certified SDVOSB, VOSB, Hub zone, 8(a), women-owned concern. If standard company brochures will be provided as a response to this Source Sought, ensure that additional information tailored to this notice is included.\nThis is not a solicitation for quotes. If a solicitation is issued, it will be announced on the Contract Opportunities website https://sam.gov at a later date, and all interested parties must respond to that solicitation announcement separately from the response to this announcement.\nContractors must be registered in System for Award Management (SAM), see internet site: https://www.sam.gov for information about registration.\nIdentify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.\nDo you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?\nIf you are in GSA, please provide schedule and contract number.\nResponses to this notice must be submitted via email to daymeion.brantley@va.gov. No telephone inquiries will be accepted.\nDISCLAIMER This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought.\nVeterans Affairs, NCO-9, is seeking information for vendors interested and capable of providing items meeting the below saliant characteristics:\n******************************************************\nUnit Dose Packaging Machine:\nSaliant Characteristics:\nThe system will need to have the ability to communicate with VISTA use HL7 messaging.\nPackager will have a touch screen for navigation as an all-in-one, with biometric scanning for user login.\nPackager cannot exceed the following dimensions due to space limitations: 48 Width, 90 Height, 48 Deep. This space has the necessary data and power requirements in pharmacy. There is not space sufficient in any other location in current pharmacy design.\nPackager must fit through pharmacy door (46 width and 83 height)\nMust have at least 400-canister capacity.\nMust include a special tablet system or STS.\nPackager must have a dual tray system allowing users to pre-fill or stage two trays at a time, providing continuous dispensing of non-canister medications.\nThe packaging system must have software features allowing users to use a different National Drug Code (NDC) if the primary NDC for an order has ran out of inventory; to pause a batch during a production run to work on another batch allowing users to come back to the paused batch and pick up where it left off; group or daisy chain canisters together to reduce refill rates for high volume or large pill; skip a medication if unavailable then removing it from the order staging it as separate order when inventory is available; and allow users to separate an order with multiple patients into separate orders at the packager level.\nPackager must have a swappable lower packaging unit for onsite redundancy to eliminate downtime.\nPackaging system will use a clamp and seal system to efficiently seal pre-folded paper with a serrated edge to ensure pouches are produced with less errors and make it easy to access medications.\nPackager must have auto-correcting motor bases preventing jams while dispensing from canisters.\nSystem must have reporting capabilities giving users the ability to check user metrics and run audit reports.\nSystem must have self-calibration canister kits for canisters (ability to modify canisters to fit different shape and size medications without replacing canister).\nSystem must have a set of universal, manually adjustable canisters allowing the pharmacy staff to calibrate canister for new NDC s without the need to swap out canister parts.\nSystem must have automatic canister recognition chip system available, which will enable any canister to be seated in any location in the packager.\nSystem must have the ability to change pouch sizes to fit different sized medications.\nSystem must be able to print custom labels (color included)\nPackages produced from system must be individually packaged and at a minimum contain: drug name, dose, dosage form, lot number, expiration date, and Bar Code Medication Administration (BCMA) compatible barcode/ 2-D printing options.\nSystem must be compatible with Windows 10\nPackage must be most current version of software and/or system.\nSystem must have HL7 interface with pharmacy system Cerner / Vista/ Automated Dispensing Cabinets.\nSystems first year s software licensing is included in initial purchase.\nSystem must have a pouch verification system that can verify label and contents of each packet to improve accuracy and efficiency.\nPouch verification system must be able to produce a cut and rolled group of medications by patient, facility, or hour of administration.\nCompany will provide at minimum 3 days of training on both campuses for staff to be adequately trained.","html":"This not a request for quotes; the Government is seeking information for market research purposes only. VA Network Contracting Office (NCO) 9 is seeking sources interested and capable of providing the items as described in the attached Product Description. \nThe North American Industry Classification System (NAICS) is 339112   SURGICAL AND MEDICAL INSTRUMENT MANUFACTURING\nThe Service Code (PSC) is 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES\n\nResponses to this notice shall include company/individual name, size status for the above reference NAICS code, a service capability statement, SAM Entity Unique Identifier (EUI), address, point of contact, and examples of similar facilities to which similar items have been provided.\nContractors must provide information on whether they are certified SDVOSB, VOSB, Hub zone, 8(a), women-owned concern. If standard company brochures will be provided as a response to this Source Sought, ensure that additional information tailored to this notice is included.\nThis is not a solicitation for quotes. If a solicitation is issued, it will be announced on the Contract Opportunities website https://sam.gov at a later date, and all interested parties must respond to that solicitation announcement separately from the response to this announcement. \nContractors must be registered in System for Award Management (SAM), see internet site: https://www.sam.gov for information about registration.\nIdentify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.\nDo you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?\nIf you are in GSA, please provide schedule and contract number.\nResponses to this notice must be submitted via email to daymeion.brantley@va.gov. No telephone inquiries will be accepted.\nDISCLAIMER This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought.\nVeterans Affairs, NCO-9, is seeking information for vendors interested and capable of providing items meeting the below saliant characteristics:\n******************************************************\nUnit Dose Packaging Machine:\nSaliant Characteristics:\nThe system will need to have the ability to communicate with VISTA use HL7 messaging.\nPackager will have a touch screen for navigation as an all-in-one, with biometric scanning for user login.\nPackager cannot exceed the following dimensions due to space limitations: 48  Width, 90 Height, 48  Deep. This space has the necessary data and power requirements in pharmacy.  There is not space sufficient in any other location in current pharmacy design.\nPackager must fit through pharmacy door (46  width and 83  height)\nMust have at least 400-canister capacity.\nMust include a special tablet system or STS.\nPackager must have a dual tray system allowing users to  pre-fill  or stage two trays at a time, providing continuous dispensing of non-canister medications.\nThe packaging system must have software features allowing users to use a different National Drug Code (NDC) if the primary NDC for an order has ran out of inventory; to pause a batch during a production run to work on another batch allowing users to come back to the paused batch and pick up where it left off; group or daisy chain canisters together to reduce refill rates for high volume or large pill; skip a medication if unavailable then removing it from the order staging it as separate order when inventory is available; and allow users to separate an order with multiple patients into separate orders at the packager level.\nPackager must have a swappable lower packaging unit for onsite redundancy to eliminate downtime.\nPackaging system will use a clamp and seal system to efficiently seal pre-folded paper with a serrated edge to ensure pouches are produced with less errors and make it easy to access medications.\nPackager must have auto-correcting motor bases preventing jams while dispensing from canisters.\nSystem must have reporting capabilities giving users the ability to check user metrics and run audit reports.\nSystem must have self-calibration canister kits for canisters (ability to modify canisters to fit different shape and size medications without replacing canister).\nSystem must have a set of universal, manually adjustable canisters allowing the pharmacy staff to calibrate canister for new NDC s without the need to swap out canister parts.\nSystem must have automatic canister recognition chip system available, which will enable any canister to be seated in any location in the packager.\nSystem must have the ability to change pouch sizes to fit different sized medications.\nSystem must be able to print custom labels (color included)\nPackages produced from system must be individually packaged and at a minimum contain: drug name, dose, dosage form, lot number, expiration date, and Bar Code Medication Administration (BCMA) compatible barcode/ 2-D printing options.\nSystem must be compatible with Windows 10\nPackage must be most current version of software and/or system.\nSystem must have HL7 interface with pharmacy system Cerner / Vista/ Automated Dispensing Cabinets.\nSystems first year s software licensing is included in initial purchase. \nSystem must have a pouch verification system that can verify label and contents of each packet to improve accuracy and efficiency.\nPouch verification system must be able to produce a cut and rolled group of medications by patient, facility, or hour of administration.\nCompany will provide at minimum 3 days of training on both campuses for staff to be adequately trained.","origin":"detail"},"contacts":[{"name":"Daymeion Brantley","role":"primary","email":"daymeion.brantley@va.gov","phone":"615.225.3616","title":"Contract Specialist"}],"place_of_performance":{"zip":"37129","city":{"code":"51560","name":"Murfreesboro"},"state":{"code":"TN","name":"Tennessee"},"street":"Alvin C. York VA Medical Center 3400 Lebanon Rd","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"37129","city":"MURFREESBORO","state":"TN","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"e55b20a6d1134853aaa4d8008af40a8b","name":"36C24925Q0182.docx","kind":"file","mime_type":".docx","size_bytes":18951,"posted_at":"2025-03-17T12:18:44.363Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e55b20a6d1134853aaa4d8008af40a8b/download","mirrored":false},{"resource_id":"84dc19ccf1c549589a8dfe2522102b80","name":"https://www.va.gov/","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-03-17T12:18:44.363Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/","mirrored":false}],"awards":[],"related":[{"key":"36C24927B0001","latest_notice_id":"3505c1f7e0584df499030ca75a30294e","title":"R602--Medical Courier Services","solicitation_number":"36C24927B0001","notice_type":"p","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-10-16","notices":1,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"492110","psc":"R602","set_aside":"SDVOSBC","state":"KY","county":"21111","county_name":"Jefferson County","city":"2148000","city_name":"Louisville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-17T03:49:26.118050Z"},{"key":"36C24927Q0014","latest_notice_id":"65a1ee030b6a40e682c7f6b349814272","title":"R614--Tennessee Valley Healthcare Services Document Destruction Shredding Services Base plus 4 year contract","solicitation_number":"36C24927Q0014","notice_type":"o","first_type":"p","first_posted":"2026-10-15","last_posted":"2026-11-25","notices":7,"due_at":"2026-12-02T16:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"561990","psc":"R614","set_aside":"SDVOSBC","state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C24927R0021","latest_notice_id":"74731079f9214f979cc1b669d71e504a","title":"Z1DA--Design Building (DB) 626-27-504 MHEOCC Compliance TVHS VAMC (Nashville Campus)","solicitation_number":"36C24927R0021","notice_type":"p","first_type":"p","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24927B0002","latest_notice_id":"d4fbb4ac5a81458a955b193f1cef4be0","title":"Z2LZ--626-25-104 Garage Suicide Protection","solicitation_number":"36C24927B0002","notice_type":"o","first_type":"p","first_posted":"2026-10-13","last_posted":"2026-11-16","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"236220","psc":"Z2LZ","set_aside":"SDVOSBC","state":"TN","county":"47037","county_name":"Davidson County","city":"4752006","city_name":"Nashville-Davidson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927Q00380001","latest_notice_id":"56da5de8b8ba49238abb7f24fbbfacad","title":"H361--LEX Triannual Energy Study and ARC Flash Testing","solicitation_number":"36C24927Q0038_0001","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-03T17:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"238210","psc":"H361","set_aside":"SDVOSBC","state":"KY","county":"21067","county_name":"Fayette County","city":"2146027","city_name":"Lexington-Fayette","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C26227Q0152","latest_notice_id":"9b6180e4020d4cb29db1bd3cb54509c4","title":"6515--Battery Packs and Wi-Fi Cards","solicitation_number":"36C26227Q0152","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"339112","psc":"6515","set_aside":null,"state":"AZ","county":"04013","county_name":"Maricopa County","city":"0455000","city_name":"Phoenix","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":14,"indexable":false}