{"canonical":"https://sealedbidder.com/opportunities/36c24827q0127","key":"36C24827Q0127","url":"https://sealedbidder.com/opportunities/36c24827q0127","title":"6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE","solicitation_number":"36C24827Q0127","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-16T19:00:00Z","first_posted":"2026-11-10","last_posted":"2026-11-10","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"339112","psc":"6515","set_aside":null,"place_state":"FL","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"12103","place_county_name":"Pinellas County","place_city":"1204200","place_city_name":"Bay Pines","winner":null,"award_amount":null,"publications":[{"notice_id":"32182eebd580472a987ff2bf90fc48fe","title":"6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE","solicitation_number":"36C24827Q0127","notice_type":"r","base_type":"r","posted":"2026-11-10","posted_at":"2026-11-10T19:22:05.786Z","due_at":"2026-11-16T19:00:00Z","due_date":"2026-11-16","cancelled":false,"archived":false,"archive_date":"2026-11-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/32182eebd580472a987ff2bf90fc48fe/view","enriched":true,"history":[{"index":1,"title":"6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:22:05.786Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"32182eebd580472a987ff2bf90fc48fe","solicitation_number":"36C24827Q0127"}]}],"latest_notice_id":"32182eebd580472a987ff2bf90fc48fe","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-11-10","posted_at":"2026-11-10T19:22:05.786Z","created_at":"2026-11-10T19:22:03.518Z","modified_at":"2026-11-10T19:22:05.786Z","response_deadline":{"raw":"2026-11-16T14:00:00-05:00","utc":"2026-11-16T19:00:00Z","date":"2026-11-16","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/32182eebd580472a987ff2bf90fc48fe/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-26","archive_type":"auto_custom"},"history":[{"index":1,"title":"6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-10T19:22:05.786Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"32182eebd580472a987ff2bf90fc48fe","solicitation_number":"36C24827Q0127"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"32182eebd580472a987ff2bf90fc48fe","lineage_id":"32182eebd580472a987ff2bf90fc48fe","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T07:44:59.381584580Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"0257206118ebe9482b80da2b24f1e441-27\"","fetched_at":"2026-11-11T04:50:18.941800608Z","row_sha256":"a716c9538e215d1e0ce4bec531bace89d865ba4f3f47a4183ccf65ede35e6f0a","last_modified":"2026-11-11T04:30:18Z"},"updated_at":"2026-11-12T07:44:59.381584580Z","first_seen_at":"2026-11-11T04:50:18.941800608Z"},"description":{"html":"Good day, SDVOSB s, VOSB s & SB's   Sources Sought INTENT TO SOLE SOURCE  Pre-Solicitation.\nThis Sources Sought is issued solely for informational and planning purposes only.Â  It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs  VOSBs , or SBs .Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â  If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. \n        Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation.Â  I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks.\n1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744  is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. \n2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care.\n2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. \n3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. \n4.Period of Performance: The product is requested to be delivered no later than December 19th. \n5.Type of Contract: Supply: Firm, Fixed Price.\n6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. \n  6.1  Salient Characteristics  \nNAME BRAND - Equipment Requirement: GE Healthcare\nQTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer\nQTY. 6   (P/N: UA2511) Reprocessing Trays for E14C4T\n\nEquipment Requirement:\nMinimum Required Features and Specifications\nType / Intended Use: \nMust be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications.\nMust provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes.\n\nFrequency & Imaging Performance:  \nMust operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate.\nMust support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system).\n\nBiopsy and Procedural Capability: \nMust include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange.\nMust accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments.\nMust permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures.\n\n4. Design & Ergonomics\nMust be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use.\nMust include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle.\nMust be designed for one-handed operation and compatible with sterile probe covers.\n\n5. Compatibility\nMust be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms.\n\nMust connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters.\n\n6. Cleaning & Sterilization\nMust be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes.\n\nMust be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide.\n\n7. Construction & Safety\nMust be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards).\nMust comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits.\nMust be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use.\n\nSummary Table\nFeature Category\nRequirement\nType\nTriplane transrectal prostate ultrasound transducer\nFrequency\n4 14 MHz\nImaging Modes\nB, M, Color Doppler, Power Doppler (Elastography optional)\nBiopsy Capability\nIntegrated dual-plane biopsy guide\nNeedle Compatibility\n17 18 G\nOperation\nOne-handed, Smart Button on probe\nSterilization\nFully immersible, high-level disinfectable\nCompatibility\nbk3000, bk5000, bkActiv, bkSpecto\nIntended Use\nProstate imaging and biopsy guidance\nCondition\nNew OEM product, OEM warranty","text":"Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation.\nThis Sources Sought is issued solely for informational and planning purposes only.Â It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs .Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.\nPlease reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation.Â I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks.\n1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer.\n2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care.\n2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays.\n3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment.\n4.Period of Performance: The product is requested to be delivered no later than December 19th.\n5.Type of Contract: Supply: Firm, Fixed Price.\n6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below.\n6.1 Salient Characteristics\nNAME BRAND - Equipment Requirement: GE Healthcare\nQTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer\nQTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T\n\nEquipment Requirement:\nMinimum Required Features and Specifications\nType / Intended Use:\nMust be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications.\nMust provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes.\n\nFrequency & Imaging Performance:\nMust operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate.\nMust support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system).\n\nBiopsy and Procedural Capability:\nMust include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange.\nMust accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments.\nMust permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures.\n\n4. Design & Ergonomics\nMust be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use.\nMust include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle.\nMust be designed for one-handed operation and compatible with sterile probe covers.\n\n5. Compatibility\nMust be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms.\n\nMust connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters.\n\n6. Cleaning & Sterilization\nMust be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes.\n\nMust be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide.\n\n7. Construction & Safety\nMust be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards).\nMust comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits.\nMust be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use.\n\nSummary Table\nFeature Category\nRequirement\nType\nTriplane transrectal prostate ultrasound transducer\nFrequency\n4 14 MHz\nImaging Modes\nB, M, Color Doppler, Power Doppler (Elastography optional)\nBiopsy Capability\nIntegrated dual-plane biopsy guide\nNeedle Compatibility\n17 18 G\nOperation\nOne-handed, Smart Button on probe\nSterilization\nFully immersible, high-level disinfectable\nCompatibility\nbk3000, bk5000, bkActiv, bkSpecto\nIntended Use\nProstate imaging and biopsy guidance\nCondition\nNew OEM product, OEM warranty","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24827Q0127","place_of_performance":{"zip":"33744","city":{"code":"4200","name":"Bay Pines"},"state":{"code":"FL","name":"Florida"},"street":"C.W. Bill Young Veterans Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10000 Bay Pines Blvd."},"product_service_code":"6515"}],"due_at":"2026-11-16T19:00:00Z","due_date":"2026-11-16","closes_at":"2026-11-16T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-11T04:53:52.348876Z","principal_notice_id":"32182eebd580472a987ff2bf90fc48fe","description":{"text":"Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation.\nThis Sources Sought is issued solely for informational and planning purposes only.Â It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs .Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.\nPlease reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation.Â I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks.\n1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer.\n2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care.\n2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays.\n3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment.\n4.Period of Performance: The product is requested to be delivered no later than December 19th.\n5.Type of Contract: Supply: Firm, Fixed Price.\n6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below.\n6.1 Salient Characteristics\nNAME BRAND - Equipment Requirement: GE Healthcare\nQTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer\nQTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T\n\nEquipment Requirement:\nMinimum Required Features and Specifications\nType / Intended Use:\nMust be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications.\nMust provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes.\n\nFrequency & Imaging Performance:\nMust operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate.\nMust support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system).\n\nBiopsy and Procedural Capability:\nMust include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange.\nMust accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments.\nMust permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures.\n\n4. Design & Ergonomics\nMust be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use.\nMust include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle.\nMust be designed for one-handed operation and compatible with sterile probe covers.\n\n5. Compatibility\nMust be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms.\n\nMust connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters.\n\n6. Cleaning & Sterilization\nMust be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes.\n\nMust be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide.\n\n7. Construction & Safety\nMust be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards).\nMust comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits.\nMust be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use.\n\nSummary Table\nFeature Category\nRequirement\nType\nTriplane transrectal prostate ultrasound transducer\nFrequency\n4 14 MHz\nImaging Modes\nB, M, Color Doppler, Power Doppler (Elastography optional)\nBiopsy Capability\nIntegrated dual-plane biopsy guide\nNeedle Compatibility\n17 18 G\nOperation\nOne-handed, Smart Button on probe\nSterilization\nFully immersible, high-level disinfectable\nCompatibility\nbk3000, bk5000, bkActiv, bkSpecto\nIntended Use\nProstate imaging and biopsy guidance\nCondition\nNew OEM product, OEM warranty","html":"Good day, SDVOSB s, VOSB s & SB's   Sources Sought INTENT TO SOLE SOURCE  Pre-Solicitation.\nThis Sources Sought is issued solely for informational and planning purposes only.Â  It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs  VOSBs , or SBs .Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â  If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. \n        Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation.Â  I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks.\n1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744  is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. \n2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care.\n2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. \n3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. \n4.Period of Performance: The product is requested to be delivered no later than December 19th. \n5.Type of Contract: Supply: Firm, Fixed Price.\n6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. \n  6.1  Salient Characteristics  \nNAME BRAND - Equipment Requirement: GE Healthcare\nQTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer\nQTY. 6   (P/N: UA2511) Reprocessing Trays for E14C4T\n\nEquipment Requirement:\nMinimum Required Features and Specifications\nType / Intended Use: \nMust be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications.\nMust provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes.\n\nFrequency & Imaging Performance:  \nMust operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate.\nMust support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system).\n\nBiopsy and Procedural Capability: \nMust include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange.\nMust accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments.\nMust permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures.\n\n4. Design & Ergonomics\nMust be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use.\nMust include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle.\nMust be designed for one-handed operation and compatible with sterile probe covers.\n\n5. Compatibility\nMust be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms.\n\nMust connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters.\n\n6. Cleaning & Sterilization\nMust be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes.\n\nMust be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide.\n\n7. Construction & Safety\nMust be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards).\nMust comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits.\nMust be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use.\n\nSummary Table\nFeature Category\nRequirement\nType\nTriplane transrectal prostate ultrasound transducer\nFrequency\n4 14 MHz\nImaging Modes\nB, M, Color Doppler, Power Doppler (Elastography optional)\nBiopsy Capability\nIntegrated dual-plane biopsy guide\nNeedle Compatibility\n17 18 G\nOperation\nOne-handed, Smart Button on probe\nSterilization\nFully immersible, high-level disinfectable\nCompatibility\nbk3000, bk5000, bkActiv, bkSpecto\nIntended Use\nProstate imaging and biopsy guidance\nCondition\nNew OEM product, OEM warranty","origin":"detail"},"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"place_of_performance":{"zip":"33744","city":{"code":"4200","name":"Bay Pines"},"state":{"code":"FL","name":"Florida"},"street":"C.W. Bill Young Veterans Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10000 Bay Pines Blvd."},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"f7f4f543bece4e2cbef920cce15d9230","name":"36C24827Q0127.docx","kind":"file","mime_type":".docx","size_bytes":20491,"posted_at":"2026-11-10T19:22:05.786Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f7f4f543bece4e2cbef920cce15d9230/download","mirrored":false},{"resource_id":"a421bba089dd4db2a24947e71bf4407b","name":"Department of Veterans Affairs","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-10T19:22:05.786Z","export_controlled":false,"sha256":null,"url":"http://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C24827Q0155","latest_notice_id":"831665dca3fc431482f486284606c5a5","title":"J026--Pneumatic Tube System Preventive Maintenance","solicitation_number":"36C24827Q0155","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238290","psc":"J026","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24827Q0143","latest_notice_id":"06bab5721d954ba4a41ceb4b0ae7266c","title":"H199--FY27 Cathodic Protection Inspection and Testing","solicitation_number":"36C24827Q0143","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"541380","psc":"H199","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"},{"key":"36C24827Q0152","latest_notice_id":"d164c447673a46eab4845cf7111b79ac","title":"6515--Fresenius 5008X Machines","solicitation_number":"36C24827Q0152","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"6515","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24827Q0071","latest_notice_id":"810da644796a4fd0bf380df7556d161c","title":"S205--FY27 Solid Waste Collection Services","solicitation_number":"36C24827Q0071","notice_type":"o","first_type":"r","first_posted":"2026-10-19","last_posted":"2026-11-20","notices":4,"due_at":"2026-12-01T16:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"562111","psc":"S205","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"W911S227U0170","latest_notice_id":"8e384efad4304afa9f8a55c7438674ba","title":"MEDICAL EQUIPMENT AND SUPPLIES","solicitation_number":"W911S227U0170","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-25T06:17:21.102542Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":17,"indexable":true}