{"canonical":"https://sealedbidder.com/opportunities/36c24826q0451","key":"36C24826Q0451","url":"https://sealedbidder.com/opportunities/36c24826q0451","title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-24T17:00:00Z","first_posted":"2026-03-16","last_posted":"2026-10-08","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","place_state":"FL","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"12057","place_county_name":"Hillsborough County","place_city":"1271000","place_city_name":"Tampa","winner":"NAPC & HSCC JV LLC","award_amount":"10720445.00","publications":[{"notice_id":"f2b49f4b6b9548a993a4a25d5b0d9634","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"p","base_type":"p","posted":"2026-03-16","posted_at":"2026-03-16T16:54:44.001Z","due_at":"2026-03-31T18:00:00Z","due_date":"2026-03-31","cancelled":false,"archived":true,"archive_date":"2026-07-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f2b49f4b6b9548a993a4a25d5b0d9634/view","enriched":true,"history":[{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"08a6d65ea8fa4da986af300bbe164ef6","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"p","posted":"2026-04-01","posted_at":"2026-04-01T11:15:16.222Z","due_at":"2026-05-05T18:00:00Z","due_date":"2026-05-05","cancelled":false,"archived":false,"archive_date":"2026-08-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/08a6d65ea8fa4da986af300bbe164ef6/view","enriched":true,"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"a295abe76d8947f699c16cf67e4e31e3","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-04-01","posted_at":"2026-04-01T11:24:30.271Z","due_at":"2026-05-01T18:00:00Z","due_date":"2026-05-01","cancelled":false,"archived":false,"archive_date":"2026-08-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a295abe76d8947f699c16cf67e4e31e3/view","enriched":true,"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"c639e4817c5745d7beaa2d91026fcc16","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-04-01","posted_at":"2026-04-01T18:24:47.372Z","due_at":"2026-05-01T18:00:00Z","due_date":"2026-05-01","cancelled":false,"archived":false,"archive_date":"2026-08-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c639e4817c5745d7beaa2d91026fcc16/view","enriched":true,"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"6291e62d78434076aa9749ab19559b65","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-04-16","posted_at":"2026-04-16T19:05:15.359Z","due_at":"2026-06-19T18:00:00Z","due_date":"2026-06-19","cancelled":false,"archived":false,"archive_date":"2026-07-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6291e62d78434076aa9749ab19559b65/view","enriched":true,"history":[{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"2e79fc68a47749059be0b149e91baaa6","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-06-15","posted_at":"2026-06-15T19:20:48.932Z","due_at":"2026-07-14T18:00:00Z","due_date":"2026-07-14","cancelled":false,"archived":false,"archive_date":"2026-08-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2e79fc68a47749059be0b149e91baaa6/view","enriched":true,"history":[{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"b4995cfb5ccf409e889da7b46fb84aa1","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-07-09","posted_at":"2026-07-09T21:01:36.253Z","due_at":"2026-07-24T17:00:00Z","due_date":"2026-07-24","cancelled":null,"archived":null,"archive_date":"2026-12-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b4995cfb5ccf409e889da7b46fb84aa1/view","enriched":true,"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"13231759ae574efca3262a0f7cb985d1","title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"o","base_type":"o","posted":"2026-07-10","posted_at":"2026-07-10T11:23:22.862Z","due_at":"2026-07-24T17:00:00Z","due_date":"2026-07-24","cancelled":null,"archived":null,"archive_date":"2026-12-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/13231759ae574efca3262a0f7cb985d1/view","enriched":true,"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"c76bc30c8f604a809cdaf6ce7c80fab8","title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"a","base_type":"o","posted":"2026-10-08","posted_at":"2026-10-08T18:41:22.994Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-11-07","removed_at":null,"award_number":"36C24827C0004","awardee_name":"NAPC & HSCC JV LLC","amount":"10720445.00","link_sam":"https://sam.gov/workspace/contract/opp/c76bc30c8f604a809cdaf6ce7c80fab8/view","enriched":true,"history":[{"index":2,"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T18:41:22.994Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"c76bc30c8f604a809cdaf6ce7c80fab8","solicitation_number":"36C24826Q0451","related_opportunity_id":"13231759ae574efca3262a0f7cb985d1"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]},{"notice_id":"ccef57f1430a481ca9bdfd7bc09247f7","title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","solicitation_number":"36C24826Q0451","notice_type":"a","base_type":"o","posted":"2026-10-08","posted_at":"2026-10-08T18:41:23.582Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-11-07","removed_at":null,"award_number":"36C24827C0004","awardee_name":"NAPC & HSCC JV LLC","amount":"10720445.00","link_sam":"https://sam.gov/workspace/contract/opp/ccef57f1430a481ca9bdfd7bc09247f7/view","enriched":true,"history":[{"index":2,"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T18:41:23.582Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ccef57f1430a481ca9bdfd7bc09247f7","solicitation_number":"36C24826Q0451","related_opportunity_id":"13231759ae574efca3262a0f7cb985d1"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}]}],"latest_notice_id":"ccef57f1430a481ca9bdfd7bc09247f7","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-16","posted_at":"2026-03-16T16:54:44.001Z","created_at":"2026-03-16T16:54:27.595Z","modified_at":"2026-07-09T03:55:45.636Z","response_deadline":{"raw":"2026-03-31T14:00:00-04:00","utc":"2026-03-31T18:00:00Z","date":"2026-03-31","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f2b49f4b6b9548a993a4a25d5b0d9634/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-08","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"DAVID HERNANDEZ","role":"primary","email":"DAVID.HERNANDEZ1@VA.GOV","phone":"813-893-3904","title":"CONTRACT SPECIALIST"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"f2b49f4b6b9548a993a4a25d5b0d9634","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T03:25:45.332135142Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"709a8af2a078531b53aed713cba02a305d1af7fd9efd3294b7049e8e4132b15d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T03:25:45.332135142Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"THIS IS A PRESOLICITATION NOTICE OF A SET-ASIDE FOR SDVOSB BB RENOVATE GROUND FLOOR HALLS AND WALLS. This procurement is set-aside based on an order of priority as established in 38 U.S.C. 8127. \nSET ASIDE FOR SERVICE DISABLE VETERANS OWNED SMALL BUSINESS(SDVOSB)\nThis is a pre-solicitation notice only. No contract shall be awarded from this pre-solicitation notice. A request for Quote will be posted on or about 04/15/2026. Project # 673-21-153 BB RENOVATE GROUND FLOOR HALLS AND WALLS, at the James A Haley Veterans Affairs Medical Center, located at 13000 Bruce B Downs Blvd, Tampa, FL 33612, RFQ # 36C24826Q0451.\nTHE BID/BUILD CONTRACT SHALL INCLUDE include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attached SOW)\nThe NAICS code for this procurement is 236220, Commercial and Institutional Building Construction with a small business size standard of $45M.  The VAAR 836.204 magnitude of this project is between $5,000,000.00 and $10,000,000.00. The project will be 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. All businesses desiring to be considered must be registered with SAM.gov prior to contract award, during contract period of performance, and must continue to remain registered through the final invoice payment. Business size and NAICS will be verified at Small Business Search (https://search.certifications.sba.gov/ ). The Contracting Officer for this project will be David Hernandez\nThis is a pre-solicitation notice only. No contract shall be awarded from this pre-solicitation notice. The request for proposal (RFQ) with SPECs and further details will be published after the closing of the synopsis.  All responsible sourcesÂ mayÂ submit a proposal when requested, whichÂ shallÂ be considered by the agency. \n SDVOSBs are encouraged to respond to communicate interest in competing for this requirement to support requirement set-aside. \nTo confirm sufficient eligible SDVOSB, please contact Contract Specialists David Hernandez at David.hernandez1@va.gov","text":"THIS IS A PRESOLICITATION NOTICE OF A SET-ASIDE FOR SDVOSB BB RENOVATE GROUND FLOOR HALLS AND WALLS. This procurement is set-aside based on an order of priority as established in 38 U.S.C. 8127.\nSET ASIDE FOR SERVICE DISABLE VETERANS OWNED SMALL BUSINESS(SDVOSB)\nThis is a pre-solicitation notice only. No contract shall be awarded from this pre-solicitation notice. A request for Quote will be posted on or about 04/15/2026. Project # 673-21-153 BB RENOVATE GROUND FLOOR HALLS AND WALLS, at the James A Haley Veterans Affairs Medical Center, located at 13000 Bruce B Downs Blvd, Tampa, FL 33612, RFQ # 36C24826Q0451.\nTHE BID/BUILD CONTRACT SHALL INCLUDE include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attached SOW)\nThe NAICS code for this procurement is 236220, Commercial and Institutional Building Construction with a small business size standard of $45M. The VAAR 836.204 magnitude of this project is between $5,000,000.00 and $10,000,000.00. The project will be 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. All businesses desiring to be considered must be registered with SAM.gov prior to contract award, during contract period of performance, and must continue to remain registered through the final invoice payment. Business size and NAICS will be verified at Small Business Search (https://search.certifications.sba.gov/ ). The Contracting Officer for this project will be David Hernandez\nThis is a pre-solicitation notice only. No contract shall be awarded from this pre-solicitation notice. The request for proposal (RFQ) with SPECs and further details will be published after the closing of the synopsis. All responsible sourcesÂ mayÂ submit a proposal when requested, whichÂ shallÂ be considered by the agency.\nSDVOSBs are encouraged to respond to communicate interest in competing for this requirement to support requirement set-aside.\nTo confirm sufficient eligible SDVOSB, please contact Contract Specialists David Hernandez at David.hernandez1@va.gov","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","place_of_performance":{"zip":"33612","city":{"name":"TAMPA"},"state":{"name":"FL"},"street":"JAMES A. HALEY VAMC 13000 Bruce B Downs Blvd"},"product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-01","posted_at":"2026-04-01T11:15:16.222Z","created_at":"2026-04-01T11:14:26.803Z","modified_at":"2026-04-01T11:24:30.271Z","response_deadline":{"raw":"2026-05-05T14:00:00-04:00","utc":"2026-05-05T18:00:00Z","date":"2026-05-05","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/08a6d65ea8fa4da986af300bbe164ef6/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-12","archive_type":"auto_custom"},"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"08a6d65ea8fa4da986af300bbe164ef6","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T07:35:12.557846937Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"042feb2b2e18a4915e4b8067c6fb80f6cd82edf1fa93f83b3b251195d568a141","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T07:35:12.557846937Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"INSTRUCTION TO OFFERORS\nISSUE DATE: 03/10/2026 QUOTE DUE DATE: 04/06/2026 at 1:00PM EST.\nPROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612.\nOFFICE ISSUING THIS REQUEST:\n          Department of Veterans Affairs Network Contracting Office (NCO) 8\n                        Point of Contact (POC): David Hernandez \n                        Email:  David.hernandez1@va.gov ; Phone: (813) 893-3904\nPROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments)\nPART I   GENERAL INFORMATION\nAll references to  Bid  or  Bidder  shall be understood to mean  Offer  or  Offeror .\nMAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00\nSITE VISIT: An organized site visit is planned for 04/14/2026 at 10:00 AM EST. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below.\nOFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected. \nREQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov  No telephone RFIs will be accepted.  The cutoff for submission of RFIs is 04/21/2026 at 2:00PM EST.\nSPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors.  \nAny reference contained within contract specifications and/or drawings to the  VA Engineer ,  Resident Engineer ,  Senior Resident Engineer ,  Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with  Contracting Officer s Representative (COR) .\nSERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/  shall be excluded from award consideration. \nSmall Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/  to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii).\nLIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING.\nFUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18)\nBONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed\nOFFER GUARANTEE: BID BOND   (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible.\nSAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0.  If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information.   Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated. \nWAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations \nCONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item\n II. QUOTE PREPARATION AND EVALUATION INFORMATION\nQUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein.  In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ.\nNOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary.  If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission. \nQUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 04/06/2026 at 1:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov .  NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED.   \nUndeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government.  \nNOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline.  Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated. \nBASIS FOR AWARD:  The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government.\nThe source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below:\nFactor 1   Technical/Management Approach\nFactor 2   Specialized Experience\nFactor 3   Schedule\nFactor 4 - Past Performance\nFactor 5   Price\n\nAll non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5).  \n The Government intends to evaluate quotes and award a contract without conducting discussions with offerors.  However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary. \n\nQUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE:\nCover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.)\nTable of Contents\nSigned SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued.\nCompleted Experience Modification Rate (EMR) Form\nCompleted Bid Bond\nCompleted and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror's bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.)\nRequired Submittals for Factor 1   Technical/Management Approach\nRequired Submittals for Factor 2   Specialized Experience\nRequired Submittals for Factor 3   Schedule\nRequired Submittals for Factor 4 - Past Performance\nRequired Submittals for Factor 5 - Price\nCOMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN).  The price QUOTE shall be submitted separate from the technical QUOTE.  The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals.\nPRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation.  Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b). \nFACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation)\nDescribe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits.\nOrganizational Chart and Narrative   Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact.\nEach individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines:\nSite Superintendent\nQuality Assurance Manager\nSite Safety and Health Officer\nProject Manager\nThe narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years  experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years  experience for each respective discipline. \nEVALUATION CRITERIA   TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities.\nMore credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award.  \nYour EMR shall not exceed 1.0.  This information shall be obtained from the bidder s/offeror's insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote.\nFACTOR II   SPECIALIZED EXPERIENCE. Narrative: 5-page maximum.\nThe offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms  experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include:\nThe prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each.\nThe original and final costs and periods of performance of the projects, with an explanation of any differences.\nHow the submitted example is similar to this project.\n Offeror shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each.\nOfferors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one.\nIn this context,  Offeror or Offeror s  refers to the proposed prime contractor, and all proposed major subcontractor(s).\nIf the project is older than five (5) years, it will be considered less relevant.\nEVALUATION CRITERIA   EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience.\nThe more recent and relevant experience, the more credit will be given.\nThe Government will place greater importance on projects performed as a prime contractor than as a subcontractor. \nThe Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations.\nFACTOR III   SCHEDULE\nThe quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion.\nThe vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule.\nThe detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days.\nThe Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote.\nIn a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues.\nEVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative.\nSchedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award.\nThe exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award\nFACTOR IV: Past Performance:\nPast performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement.\nIn the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance.\nThe prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor.  Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example:\nProject Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation)\nAll projects submitted must be at least 75% complete.\nContracting Officer and COR Name and contact information, telephone, and email\nTotal Project Value and duration. \nList of subcontractors.\nInitial/Final award amount.\nState any change orders that occurred during the project performance and the reason behind the change.\nPictures of completed work.\nDetailed description of work, including trades involved (identify the percentage of self-performed work).\nExplanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project.    \nEVALUATION CRITERIA   PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the\nevaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate.\n\nThe Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. \nNarrative   5-page maximum \nCPARS/PPQ   No maximum page limit\n FACTOR V   PRICE    Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).","text":"INSTRUCTION TO OFFERORS\nISSUE DATE: 03/10/2026 QUOTE DUE DATE: 04/06/2026 at 1:00PM EST.\nPROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612.\nOFFICE ISSUING THIS REQUEST:\nDepartment of Veterans Affairs Network Contracting Office (NCO) 8\nPoint of Contact (POC): David Hernandez\nEmail: David.hernandez1@va.gov ; Phone: (813) 893-3904\nPROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments)\nPART I GENERAL INFORMATION\nAll references to Bid or Bidder shall be understood to mean Offer or Offeror .\nMAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00\nSITE VISIT: An organized site visit is planned for 04/14/2026 at 10:00 AM EST. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below.\nOFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.\nREQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov No telephone RFIs will be accepted. The cutoff for submission of RFIs is 04/21/2026 at 2:00PM EST.\nSPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors.\nAny reference contained within contract specifications and/or drawings to the VA Engineer , Resident Engineer , Senior Resident Engineer , Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with Contracting Officer s Representative (COR) .\nSERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/ shall be excluded from award consideration.\nSmall Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/ to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii).\nLIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING.\nFUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18)\nBONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed\nOFFER GUARANTEE: BID BOND (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible.\nSAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0. If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information. Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated.\nWAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations\nCONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item\nII. QUOTE PREPARATION AND EVALUATION INFORMATION\nQUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein. In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ.\nNOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary. If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission.\nQUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 04/06/2026 at 1:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov . NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED.\nUndeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government.\nNOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline. Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated.\nBASIS FOR AWARD: The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government.\nThe source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below:\nFactor 1 Technical/Management Approach\nFactor 2 Specialized Experience\nFactor 3 Schedule\nFactor 4 - Past Performance\nFactor 5 Price\n\nAll non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5).\nThe Government intends to evaluate quotes and award a contract without conducting discussions with offerors. However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary.\n\nQUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE:\nCover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.)\nTable of Contents\nSigned SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued.\nCompleted Experience Modification Rate (EMR) Form\nCompleted Bid Bond\nCompleted and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror's bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.)\nRequired Submittals for Factor 1 Technical/Management Approach\nRequired Submittals for Factor 2 Specialized Experience\nRequired Submittals for Factor 3 Schedule\nRequired Submittals for Factor 4 - Past Performance\nRequired Submittals for Factor 5 - Price\nCOMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN). The price QUOTE shall be submitted separate from the technical QUOTE. The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals.\nPRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation. Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).\nFACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation)\nDescribe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits.\nOrganizational Chart and Narrative Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact.\nEach individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines:\nSite Superintendent\nQuality Assurance Manager\nSite Safety and Health Officer\nProject Manager\nThe narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years experience for each respective discipline.\nEVALUATION CRITERIA TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities.\nMore credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award.\nYour EMR shall not exceed 1.0. This information shall be obtained from the bidder s/offeror's insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote.\nFACTOR II SPECIALIZED EXPERIENCE. Narrative: 5-page maximum.\nThe offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include:\nThe prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each.\nThe original and final costs and periods of performance of the projects, with an explanation of any differences.\nHow the submitted example is similar to this project.\nOfferor shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each.\nOfferors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one.\nIn this context, Offeror or Offeror s refers to the proposed prime contractor, and all proposed major subcontractor(s).\nIf the project is older than five (5) years, it will be considered less relevant.\nEVALUATION CRITERIA EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience.\nThe more recent and relevant experience, the more credit will be given.\nThe Government will place greater importance on projects performed as a prime contractor than as a subcontractor.\nThe Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations.\nFACTOR III SCHEDULE\nThe quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion.\nThe vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule.\nThe detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days.\nThe Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote.\nIn a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues.\nEVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative.\nSchedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award.\nThe exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award\nFACTOR IV: Past Performance:\nPast performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement.\nIn the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance.\nThe prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor. Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example:\nProject Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation)\nAll projects submitted must be at least 75% complete.\nContracting Officer and COR Name and contact information, telephone, and email\nTotal Project Value and duration.\nList of subcontractors.\nInitial/Final award amount.\nState any change orders that occurred during the project performance and the reason behind the change.\nPictures of completed work.\nDetailed description of work, including trades involved (identify the percentage of self-performed work).\nExplanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project.\nEVALUATION CRITERIA PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the\nevaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate.\n\nThe Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance.\nNarrative 5-page maximum\nCPARS/PPQ No maximum page limit\nFACTOR V PRICE Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-01","posted_at":"2026-04-01T11:24:30.271Z","created_at":"2026-04-01T11:17:28.982Z","modified_at":"2026-04-01T18:24:47.372Z","response_deadline":{"raw":"2026-05-01T14:00:00-04:00","utc":"2026-05-01T18:00:00Z","date":"2026-05-01","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a295abe76d8947f699c16cf67e4e31e3/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-12","archive_type":"auto_custom"},"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a295abe76d8947f699c16cf67e4e31e3","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T07:39:52.060657812Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"e11128f59f3cc0900f1ba66141e578a1462bc1707e6ea40d02e1f264c48e89ea","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T07:39:52.060657812Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"<p>INSTRUCTION TO OFFERORS ISSUE DATE: 04/01/2026 QUOTE DUE DATE: 05/01/2026 at 2:00PM EST. PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612. OFFICE ISSUING THIS REQUEST: Department of Veterans Affairs Network Contracting Office (NCO) 8 Point of Contact (POC): David Hernandez Email: David.hernandez1@va.gov ; Phone: (813) 893-3904 PROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments) PART I GENERAL INFORMATION All references to Bid or Bidder shall be understood to mean Offer or Offeror . MAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00 SITE VISIT:&nbsp;&nbsp;<strong>An organized site visit is planned for 04/09/2026 at 1:00PM EST</strong>. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below. OFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected. REQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov No telephone RFIs will be accepted. The cutoff for submission of <strong>RFIs is 04/16/2026 at 2:00PM EST.</strong> SPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors. Any reference contained within contract specifications and/or drawings to the VA Engineer , Resident Engineer , Senior Resident Engineer , Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with Contracting Officer s Representative (COR) . SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/ shall be excluded from award consideration. Small Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/ to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii). LIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING. FUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18) BONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed OFFER GUARANTEE: BID BOND (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible. SAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0. If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information. Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated. WAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations CONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item II. QUOTE PREPARATION AND EVALUATION INFORMATION QUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein. In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ. NOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary. If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission. QUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 05/01/2026 at 2:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov . NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED. Undeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government. NOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline. Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated. BASIS FOR AWARD: The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government. The source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below: Factor 1 Technical/Management Approach Factor 2 Specialized Experience Factor 3 Schedule Factor 4 - Past Performance Factor 5 Price All non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5). The Government intends to evaluate quotes and award a contract without conducting discussions with offerors. However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary. QUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE: Cover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.) Table of Contents Signed SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued. Completed Experience Modification Rate (EMR) Form Completed Bid Bond Completed and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror&#39;s bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.) Required Submittals for Factor 1 Technical/Management Approach Required Submittals for Factor 2 Specialized Experience Required Submittals for Factor 3 Schedule Required Submittals for Factor 4 - Past Performance Required Submittals for Factor 5 - Price COMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN). The price QUOTE shall be submitted separate from the technical QUOTE. The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals. PRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation. Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b). FACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation) Describe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits. Organizational Chart and Narrative Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact. Each individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines: Site Superintendent Quality Assurance Manager Site Safety and Health Officer Project Manager The narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years experience for each respective discipline. EVALUATION CRITERIA TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities. More credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award. Your EMR shall not exceed 1.0. This information shall be obtained from the bidder s/offeror&#39;s insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote. FACTOR II SPECIALIZED EXPERIENCE. Narrative: 5-page maximum. The offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include: The prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each. The original and final costs and periods of performance of the projects, with an explanation of any differences. How the submitted example is similar to this project. Offeror shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each. Offerors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one. In this context, Offeror or Offeror s refers to the proposed prime contractor, and all proposed major subcontractor(s). If the project is older than five (5) years, it will be considered less relevant. EVALUATION CRITERIA EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience. The more recent and relevant experience, the more credit will be given. The Government will place greater importance on projects performed as a prime contractor than as a subcontractor. The Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations. FACTOR III SCHEDULE The quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion. The vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule. The detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days. The Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote. In a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues. EVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative. Schedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award. The exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award FACTOR IV: Past Performance: Past performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. The prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor. Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example: Project Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation) All projects submitted must be at least 75% complete. Contracting Officer and COR Name and contact information, telephone, and email Total Project Value and duration. List of subcontractors. Initial/Final award amount. State any change orders that occurred during the project performance and the reason behind the change. Pictures of completed work. Detailed description of work, including trades involved (identify the percentage of self-performed work). Explanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project. EVALUATION CRITERIA PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the evaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate. The Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. Narrative 5-page maximum CPARS/PPQ No maximum page limit FACTOR V PRICE Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).</p>","text":"INSTRUCTION TO OFFERORS ISSUE DATE: 04/01/2026 QUOTE DUE DATE: 05/01/2026 at 2:00PM EST. PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612. OFFICE ISSUING THIS REQUEST: Department of Veterans Affairs Network Contracting Office (NCO) 8 Point of Contact (POC): David Hernandez Email: David.hernandez1@va.gov ; Phone: (813) 893-3904 PROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments) PART I GENERAL INFORMATION All references to Bid or Bidder shall be understood to mean Offer or Offeror . MAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00 SITE VISIT: An organized site visit is planned for 04/09/2026 at 1:00PM EST. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below. OFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected. REQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov No telephone RFIs will be accepted. The cutoff for submission of RFIs is 04/16/2026 at 2:00PM EST. SPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors. Any reference contained within contract specifications and/or drawings to the VA Engineer , Resident Engineer , Senior Resident Engineer , Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with Contracting Officer s Representative (COR) . SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/ shall be excluded from award consideration. Small Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/ to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii). LIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING. FUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18) BONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed OFFER GUARANTEE: BID BOND (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible. SAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0. If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information. Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated. WAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations CONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item II. QUOTE PREPARATION AND EVALUATION INFORMATION QUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein. In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ. NOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary. If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission. QUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 05/01/2026 at 2:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov . NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED. Undeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government. NOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline. Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated. BASIS FOR AWARD: The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government. The source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below: Factor 1 Technical/Management Approach Factor 2 Specialized Experience Factor 3 Schedule Factor 4 - Past Performance Factor 5 Price All non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5). The Government intends to evaluate quotes and award a contract without conducting discussions with offerors. However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary. QUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE: Cover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.) Table of Contents Signed SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued. Completed Experience Modification Rate (EMR) Form Completed Bid Bond Completed and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror's bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.) Required Submittals for Factor 1 Technical/Management Approach Required Submittals for Factor 2 Specialized Experience Required Submittals for Factor 3 Schedule Required Submittals for Factor 4 - Past Performance Required Submittals for Factor 5 - Price COMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN). The price QUOTE shall be submitted separate from the technical QUOTE. The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals. PRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation. Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b). FACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation) Describe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits. Organizational Chart and Narrative Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact. Each individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines: Site Superintendent Quality Assurance Manager Site Safety and Health Officer Project Manager The narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years experience for each respective discipline. EVALUATION CRITERIA TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities. More credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award. Your EMR shall not exceed 1.0. This information shall be obtained from the bidder s/offeror's insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote. FACTOR II SPECIALIZED EXPERIENCE. Narrative: 5-page maximum. The offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include: The prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each. The original and final costs and periods of performance of the projects, with an explanation of any differences. How the submitted example is similar to this project. Offeror shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each. Offerors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one. In this context, Offeror or Offeror s refers to the proposed prime contractor, and all proposed major subcontractor(s). If the project is older than five (5) years, it will be considered less relevant. EVALUATION CRITERIA EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience. The more recent and relevant experience, the more credit will be given. The Government will place greater importance on projects performed as a prime contractor than as a subcontractor. The Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations. FACTOR III SCHEDULE The quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion. The vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule. The detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days. The Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote. In a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues. EVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative. Schedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award. The exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award FACTOR IV: Past Performance: Past performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. The prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor. Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example: Project Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation) All projects submitted must be at least 75% complete. Contracting Officer and COR Name and contact information, telephone, and email Total Project Value and duration. List of subcontractors. Initial/Final award amount. State any change orders that occurred during the project performance and the reason behind the change. Pictures of completed work. Detailed description of work, including trades involved (identify the percentage of self-performed work). Explanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project. EVALUATION CRITERIA PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the evaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate. The Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. Narrative 5-page maximum CPARS/PPQ No maximum page limit FACTOR V PRICE Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-01","posted_at":"2026-04-01T18:24:47.372Z","created_at":"2026-04-01T18:24:16.359Z","modified_at":"2026-04-16T19:05:15.359Z","response_deadline":{"raw":"2026-05-01T14:00:00-04:00","utc":"2026-05-01T18:00:00Z","date":"2026-05-01","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c639e4817c5745d7beaa2d91026fcc16/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-12","archive_type":"auto_custom"},"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"c639e4817c5745d7beaa2d91026fcc16","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T07:39:06.558180094Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"4654c3a1a45cf615a54b8b72e1eeb683093485ddb2811173948a6c946b7b928a","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T07:39:06.558180094Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"<p>INSTRUCTION TO OFFERORS ISSUE DATE: 04/01/2026 QUOTE DUE DATE: 05/01/2026 at 2:00PM EST. PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612. OFFICE ISSUING THIS REQUEST: Department of Veterans Affairs Network Contracting Office (NCO) 8 Point of Contact (POC): David Hernandez Email: David.hernandez1@va.gov ; Phone: (813) 893-3904 PROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments) PART I GENERAL INFORMATION All references to Bid or Bidder shall be understood to mean Offer or Offeror . MAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00 SITE VISIT:&nbsp;&nbsp;<strong>An organized site visit is planned for 04/09/2026 at 1:00PM EST</strong>. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below. OFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected. REQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov No telephone RFIs will be accepted. The cutoff for submission of <strong>RFIs is 04/16/2026 at 2:00PM EST.</strong> SPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors. Any reference contained within contract specifications and/or drawings to the VA Engineer , Resident Engineer , Senior Resident Engineer , Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with Contracting Officer s Representative (COR) . SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/ shall be excluded from award consideration. Small Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/ to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii). LIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING. FUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18) BONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed OFFER GUARANTEE: BID BOND (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible. SAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0. If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information. Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated. WAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations CONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item II. QUOTE PREPARATION AND EVALUATION INFORMATION QUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein. In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ. NOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary. If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission. QUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 05/01/2026 at 2:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov . NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED. Undeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government. NOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline. Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated. BASIS FOR AWARD: The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government. The source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below: Factor 1 Technical/Management Approach Factor 2 Specialized Experience Factor 3 Schedule Factor 4 - Past Performance Factor 5 Price All non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5). The Government intends to evaluate quotes and award a contract without conducting discussions with offerors. However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary. QUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE: Cover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.) Table of Contents Signed SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued. Completed Experience Modification Rate (EMR) Form Completed Bid Bond Completed and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror&#39;s bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.) Required Submittals for Factor 1 Technical/Management Approach Required Submittals for Factor 2 Specialized Experience Required Submittals for Factor 3 Schedule Required Submittals for Factor 4 - Past Performance Required Submittals for Factor 5 - Price COMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN). The price QUOTE shall be submitted separate from the technical QUOTE. The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals. PRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation. Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b). FACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation) Describe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits. Organizational Chart and Narrative Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact. Each individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines: Site Superintendent Quality Assurance Manager Site Safety and Health Officer Project Manager The narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years experience for each respective discipline. EVALUATION CRITERIA TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities. More credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award. Your EMR shall not exceed 1.0. This information shall be obtained from the bidder s/offeror&#39;s insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote. FACTOR II SPECIALIZED EXPERIENCE. Narrative: 5-page maximum. The offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include: The prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each. The original and final costs and periods of performance of the projects, with an explanation of any differences. How the submitted example is similar to this project. Offeror shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each. Offerors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one. In this context, Offeror or Offeror s refers to the proposed prime contractor, and all proposed major subcontractor(s). If the project is older than five (5) years, it will be considered less relevant. EVALUATION CRITERIA EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience. The more recent and relevant experience, the more credit will be given. The Government will place greater importance on projects performed as a prime contractor than as a subcontractor. The Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations. FACTOR III SCHEDULE The quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion. The vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule. The detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days. The Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote. In a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues. EVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative. Schedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award. The exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award FACTOR IV: Past Performance: Past performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. The prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor. Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example: Project Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation) All projects submitted must be at least 75% complete. Contracting Officer and COR Name and contact information, telephone, and email Total Project Value and duration. List of subcontractors. Initial/Final award amount. State any change orders that occurred during the project performance and the reason behind the change. Pictures of completed work. Detailed description of work, including trades involved (identify the percentage of self-performed work). Explanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project. EVALUATION CRITERIA PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the evaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate. The Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. Narrative 5-page maximum CPARS/PPQ No maximum page limit FACTOR V PRICE Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).</p>","text":"INSTRUCTION TO OFFERORS ISSUE DATE: 04/01/2026 QUOTE DUE DATE: 05/01/2026 at 2:00PM EST. PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612. OFFICE ISSUING THIS REQUEST: Department of Veterans Affairs Network Contracting Office (NCO) 8 Point of Contact (POC): David Hernandez Email: David.hernandez1@va.gov ; Phone: (813) 893-3904 PROJECT SUMMARY: THE BID/BUILD CONTRACT SHALL INCLUDE but not be limited to the Renovation of the Halls and Walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement. AS REQUIRED BY DRAWINGS AND SPECIFICATIONS (See attachments) PART I GENERAL INFORMATION All references to Bid or Bidder shall be understood to mean Offer or Offeror . MAGNITUDE OF THIS PROJECT: Between $5,000,000.00 and $10,000,000.00 SITE VISIT: An organized site visit is planned for 04/09/2026 at 1:00PM EST. Meeting location is Building 42. Please contact Healthcare Engineer Kara Chaput Kara.Chaput@va.gov to confirm attendance. Technical questions are not allowed during the site visit. Please record your questions and submit them to the Contracting Officer as an RFI by the date indicated in #5 below. OFFER ACCEPTANCE PERIOD: Offers providing less than one hundred and twenty (120) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected. REQUESTS FOR INFORMATION: Requests for Information (RFIs) shall be submitted by the prime contractor, by email to David.hernandez1@va.gov No telephone RFIs will be accepted. The cutoff for submission of RFIs is 04/16/2026 at 2:00PM EST. SPECIFICATIONS AND DRAWINGS: All applicable specifications and drawings, if available, will be provided electronically in SAM.gov as attachments to this RFP. No hard copies will be made available to proposing contractors. Any reference contained within contract specifications and/or drawings to the VA Engineer , Resident Engineer , Senior Resident Engineer , Project Manager , Contracting Officer Technical Representative, or their abbreviations are to be replaced with Contracting Officer s Representative (COR) . SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS VERIFICATION: Subsequent contracts are 100% set asides for verified SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB). The award of this requirement shall not be delayed due to loss of SDVOSB verification. QUOTEs submitted by non-certified by Small Business Search https://search.certifications.sba.gov/ shall be excluded from award consideration. Small Business Verification: The Government will review Small Business Search https://search.certifications.sba.gov/ to confirm SDVOSB status verification for the submitted QUOTE. Evaluations will be performed on QUOTEs submitted by verified SDVOSB only. The Contracting Officer will use the UEI to verify that the Offeror has an active Federal Government contracts registration in SAM. IAW FAR 52.204-7(b)(1)(iii). LIMITATIONS ON SUBCONTRACTING (Reference Contract Clause VAR 852.219-75 for further information) Please, fully complete and return the LIMITATION ON SUBCONTRACTING. FUNDS. Funds are not presently available for this contract. (Reference Contract Clause FAR 52.232-18) BONDS (Reference Contract Clause FAR 52.228-15 for further information on applicability). A payment and performance bond shall be provided. The penal sum shall be one hundred percent (100%) of order price. Bonds and other payment protection shall be provided within ten (10) calendar days of award of the Contract. Notice to proceed will not be issued until the Contractor provides sufficient bonding to cover the work being performed OFFER GUARANTEE: BID BOND (SUBMIT WITH YOUR PRICE QUOTE) per FAR Clause 52.228-1 -Bid Guarantee, the amount of the bid guarantee shall be 20 percent of the bid price or $3,000,000, whichever is less. Provide with PRICE QUOTE. NOTE: A scanned copy of the original is acceptable. Bond Seal must be visible. SAFETY AND ENVIRONMENTAL RECORD (SUBMIT WITH QUOTE): Offerors shall submit information that specify the contractor in question has no more than three serious, or one repeat, or one willful OSHA or EPA violation(s) in the past three (3) years and has an Experience Modification Rate (EMR) that shall not exceed 1.0. If there is no EMR, state the reason way no EMR is available. EMR greater than 1.0 will not be acceptable. Offerors are required to complete and submit attached Past safety and environmental record or any other form that provided the above information. Offerors with an EMR greater than 1.0 will be considered ineligible and will not be evaluated. WAGE DETERMINATION: Wages for all contractors and subcontractors must comply with Davis Bacon Wage Determinations. The current Davis Bacon determination is General Decision Number: FL20260208 dated 01-02-2026. Be advised that the determination that is current at the time of the Contract award is the determination that will apply for the project. Current determinations are always available at: https://sam.gov/wage-determinations CONTRACT PERFORMANCE PERIOD: 540 calendar days after receipt of written Notice to Proceed performed in concurrent or sequential phases as indicated or required. If you anticipate long lead times for project materials, state this in the technical PROPOSAL with your anticipated lead time for the specific item II. QUOTE PREPARATION AND EVALUATION INFORMATION QUOTE PREPARATION INSTRUCTION: To ensure timely and equitable evaluation of QUOTEs, offerors must follow the instructions contained herein. In order for QUOTEs to receive full consideration for award, offerors should ensure that the information furnished in support of the QUOTE is factual, accurate, and complete, and directly responds to the requirements of this RFQ. NOTE: Your QUOTE shall be submitted as portable data files (pdf), and documents submitted shall be no larger than 7 Mega Bytes (MB) in size. Send document in separate files as deemed necessary. If separate files are submitted for specific submission, offeror shall include in the subject line right after required subject title, email number followed by the emails total to be submitted for specific submission. QUOTE SUBMISSION: All QUOTES shall be submitted by the prime contractor no later than (NLT) 05/01/2026 at 2:00PM EST. (subject to amendment) through the Point of Contact email David.hernandez1@va.gov . NO OTHER FORMS OF SUBMISSION WILL BE ACCEPTED. Undeliverable emails due to an offeror s QUOTE size, using wrong email address, or other transmission errors, is not the responsibility of the Government. NOTE: To be considered and accepted as timely the QUOTE must be received in its entirety prior to the deadline. Failure to provide a QUOTE in its entirety prior to the deadline will result in the quote will not be evaluated. BASIS FOR AWARD: The Government will award one firm-fixed-price contract to the responsible offeror whose quote conforms to the solicitation and represents the best value to the Government. The source selection process will utilize FAR Parts 15.103-1 (Tradeoff). considering the factors set forth below: Factor 1 Technical/Management Approach Factor 2 Specialized Experience Factor 3 Schedule Factor 4 - Past Performance Factor 5 Price All non-priced factors are equally important. All non-priced factors (Factors 1-4) when combined are approximately equal to price (Factor 5). The Government intends to evaluate quotes and award a contract without conducting discussions with offerors. However, the Government reserves the right to hold discussions if the Contracting Officer determines them to be necessary. QUOTE PREPARATION INSTRUCTIONS: The following must be included in the offeror s QUOTE: Cover Page with: Bid Build Project, RFP (Solicitation) Number, Project Title and Project Number, Company Information (Primary points of contact, email, address, phone numbers (including area code), DUNs number, Cage code, EUI, etc.) Table of Contents Signed SF 1442, with Blocks 14-20C completed including acknowledgement of any Amendments issued. Completed Experience Modification Rate (EMR) Form Completed Bid Bond Completed and signed VAAR 852.219-75 (The formal certification must be completed, signed and returned with the offeror's bid, quotation, or quote. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.) Required Submittals for Factor 1 Technical/Management Approach Required Submittals for Factor 2 Specialized Experience Required Submittals for Factor 3 Schedule Required Submittals for Factor 4 - Past Performance Required Submittals for Factor 5 - Price COMPLETED PRICE SCHEDULE (Total of Proposed Price of each CLIN). The price QUOTE shall be submitted separate from the technical QUOTE. The proposed prices will be analyzed for reasonableness. No pricing information shall be included in the technical submittals. PRICE EVALUATION: The Government will initially review pricing independently from the factor evaluation. Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b). FACTOR I - TECHNICAL/MANAGEMENT APPROACH. Narrative: 5-page maximum (excluding EMR documentation) Describe in a written narrative, the plan for phasing and coordinating the work so that the facility remains operational. The narrative will also detail how the contractor intends to prepare the site, renovate, and return to use within any specified time limits. Organizational Chart and Narrative Clearly describe the prime responsible firm (or firms if a J/V) and individuals as well as the roles and responsibilities of individuals proposed as key consultants and subcontractors. Provide a list of all consultants and all proposed major subcontractors, including telephone number, address, and name of contact. Each individual s name, title, duty, years of experience and experience level relating to similar contracts in size and scope (Renovate Ground Floor Halls and Walls). At a minimum, the Offeror shall provide information for the following disciplines: Site Superintendent Quality Assurance Manager Site Safety and Health Officer Project Manager The narratives for the Site Superintendent, Quality Assurance Manager, Site Safety and Health Officer, and Project Manager must show a minimum of five (5) years experience for each respective discipline on a project of similar size, scope, and complexity. The Quality Assurance Manager may be the same individual as either the superintendent or project manager but must show the minimum of five (5) years experience for each respective discipline. EVALUATION CRITERIA TECHNICAL/MANAGEMENT APPROACH: The information provided will be used to evaluate the depth of each offeror s technical understanding of the project and its management abilities. More credit will be given for approaches that meet or exceed the project requirements. Quotes which fail to demonstrate the minimum experience for each respective discipline will result in the quote being removed from consideration and the quote shall be ineligible for award. Your EMR shall not exceed 1.0. This information shall be obtained from the bidder s/offeror's insurance company and be furnished on the insurance carrier s letterhead. An EMR of more than 1.0 will result in no further consideration of the quote. Failure to submit an EMR rating will result in no further consideration of the quote. FACTOR II SPECIALIZED EXPERIENCE. Narrative: 5-page maximum. The offeror is required to submit a minimum of three (3) but no more than five (5) example projects demonstrating your firm s experience and capability similar to Renovate Ground Floor Halls and Walls. These demonstrations in similar experience and capability shall be in a healthcare environment with phasing, asbestos abatement, and trade coordination work and display the firms experience with cost control, quality of work, adaptability, and compliance with performance schedules on a project of similar scope and size. These examples shall include: The prime and/or subcontractors proposed team that they were involved in the submitted projects, and the tasks carried out by each. The original and final costs and periods of performance of the projects, with an explanation of any differences. How the submitted example is similar to this project. Offeror shall provide example projects that best represent the Offeror s work experience and capability required on this project, completed within the past five (5) years from the issuance date of this solicitation, or that are currently ongoing and substantially complete (at least 75% construction progress completed). These examples shall include the prime and/or subcontractors proposed for this project that were involved in the submitted projects and the tasks carried out by each. Offerors are responsible for providing project descriptions in sufficient detail to permit evaluation of project relevancy to this procurement and shall explain how the submitted example is similar to this one. In this context, Offeror or Offeror s refers to the proposed prime contractor, and all proposed major subcontractor(s). If the project is older than five (5) years, it will be considered less relevant. EVALUATION CRITERIA EXPERIENCE: The information provided will be used to evaluate the relevancy and depth of each Offeror s specialized experience. The more recent and relevant experience, the more credit will be given. The Government will place greater importance on projects performed as a prime contractor than as a subcontractor. The Government will place greater importance on projects that were performed at a VA HEALTHCARE ENVIRONMENT, depending upon overall role and relevant considerations. FACTOR III SCHEDULE The quote shall provide a proposed progress schedule. The progress schedule shall be in a time scaled bar graph format. The horizontal axis shall be scaled for time beginning with the Notice to Proceed and concluding with contract completion. The vertical axis SHALL shows the milestones and major portions of the contract work. Milestones SHALL include such items as material submissions, submittal acceptance, partial and final inspections, punch list completion, testing, etc. All scheduled items SHALL show a start date and a completion date, and the critical path shall be clearly identified on the schedule. The detailed schedule SHALL indicate specific tasks with dates for each step of the process including: Mobilization; Demolition and Abatement; Construction; Provisions for overtime or shift work; Timing of relocation of existing utilities; Tests and final inspection. Task durations shall be expressed in calendar days. The Offeror shall specify how much allowance has been made for bad weather or other unforeseen delays, the days of the week and the hours of construction operations during each phase of the work, and the percentage of contract completion that SHALL be achieved at the end of each month of the contract. If there is a long lead time for materials, please note this in your quote. In a narrative, the contractor shall highlight any potential problems that could affect the project schedule and provide possible contingency plans or potential solutions to avoid such issues. EVALUATION CRITERIA - SCHEDULE: The information provided will be used to evaluate the strengths, weaknesses, and any deficiencies in the schedule submission and narrative. Schedules that do not meet the overall period of performance or other timelines outlined in the statement of work/specifications will result in the quote being removed from consideration and the quote shall be ineligible for award. The exclusion of any major phases of work in the schedule will result in the quote being removed from consideration and the quote shall be ineligible for award FACTOR IV: Past Performance: Past performance information may be obtained from references provided by the offeror and from other sources known to the Government or learned during the course of the evaluation. Each offeror will be evaluated on its performance for similar type of projects. The government will focus on information that demonstrates quality of performance relative to the size and complexity of the procurement. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. The prime contractor shall provide completed Past Performance surveys of and present documented proof that they have performed projects that required work similar in size and scope to this project in the past 5 years (These examples can be the same projects as in Factor 2 or different projects); This may include a past performance from a 1ST-tier sub-contractor. Note: Any teaming or proposed sub-contractor arrangement you are submitting as part of this quote for evaluation must remain intact through contract completion unless otherwise approved by the VA. It is required. The VA needs the consent to review/consider subcontractor information Consent Letters executed by each subcontractor, teaming partner, and/or joint venture partner, authorizing the release of past performance information to the Government. Failure to provide a consent letter will preclude the Government from considering the past performance information of the subcontractor. In addition to PPQs/CPARS, provide the following information for each example: Project Number, Title, and location or facility performed (At least two (2) of the projects submitted must be the same or similar work to the project described in the solicitation) All projects submitted must be at least 75% complete. Contracting Officer and COR Name and contact information, telephone, and email Total Project Value and duration. List of subcontractors. Initial/Final award amount. State any change orders that occurred during the project performance and the reason behind the change. Pictures of completed work. Detailed description of work, including trades involved (identify the percentage of self-performed work). Explanation of why the projects were selected as the same or similar and how the experience obtained on the submitted project is pertinent to the execution of this project. EVALUATION CRITERIA PAST PERFORMANCE: The information presented by the vendor, together with information from other sources available to the Government, will be the basis for evaluation under this factor. As part of this evaluation, VA will consider the relevancy of the projects submitted, to include the size and scope/complexity. The Government may contact references and contact parties other than those identified by the offeror, and information received may be used in the evaluation of the offeror s Past Performance. The evaluation will take into account Past Performance information regarding predecessor companies, key personnel who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to this acquisition. If multiple subcontractors are provided for the same discipline, the government will use the lowest rated subcontractor in the evaluation. The Government reserves the right to obtain and evaluate Past Performance information from any source it deems appropriate. The Past Performance evaluation will consider the recency and relevancy of the past performance submissions as discussed above, and Offerors will be assigned an overall confidence rating based on the Government s expectation the Offeror will successfully accomplish the current requirements. In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance, in accordance with FAR 15.104(b)(3) Therefore, the offeror shall be determined to have unknown past performance. Narrative 5-page maximum CPARS/PPQ No maximum page limit FACTOR V PRICE Price will be evaluated for reasonableness using one or more of the techniques set forth in FAR Part 15.404-1(b).","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-16","posted_at":"2026-04-16T19:05:15.359Z","created_at":"2026-04-16T19:05:12.601Z","modified_at":"2026-06-15T19:20:48.932Z","response_deadline":{"raw":"2026-06-19T14:00:00-04:00","utc":"2026-06-19T18:00:00Z","date":"2026-06-19","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6291e62d78434076aa9749ab19559b65/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-07-19","archive_type":"auto_custom"},"history":[{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"6291e62d78434076aa9749ab19559b65","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T04:36:49.112026207Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"c2cf0427c6aa316b8dd057f6d62c3b3e98dd610550f1d47e50d131c041831303","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T04:36:49.112026207Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612\nTHE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION\nCHANGES:\nNOTIFICATION OF ASBESTOS O&M WORK DOCUMENTS\nA COPY OF THE SITE VISIT SIGN-IN SHEET\nQUOTES DUE DATE HAS BEEN CHANGED TO 06/19/2026 AT 2:00PM EST","text":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612\nTHE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION\nCHANGES:\nNOTIFICATION OF ASBESTOS O&M WORK DOCUMENTS\nA COPY OF THE SITE VISIT SIGN-IN SHEET\nQUOTES DUE DATE HAS BEEN CHANGED TO 06/19/2026 AT 2:00PM EST","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2026-06-15","posted_at":"2026-06-15T19:20:48.932Z","created_at":"2026-06-15T19:19:47.565Z","modified_at":"2026-07-09T21:01:36.253Z","response_deadline":{"raw":"2026-07-14T14:00:00-04:00","utc":"2026-07-14T18:00:00Z","date":"2026-07-14","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2e79fc68a47749059be0b149e91baaa6/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-13","archive_type":"auto_custom"},"history":[{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"2e79fc68a47749059be0b149e91baaa6","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T00:36:36.181310129Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"deda6aae9deaddb68f3985f60de49924d0d08684e74c7690ff672dd2c9bdf2f6","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T00:36:36.181310129Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612\nTHE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION\nCHANGES:\nProvide copies of Drawings, Specifications, and other documents\nUpdated Wage Determination\nAnswers to RFIs\nAdding VAAR clause 852.204-70 and 852.204-72; FAR 52.222-90\n2 sites visit to review the above ceiling inspections have been scheduled for \n06/24/2026 at 0530 EST\n06/24/2026 at 1900 EST\n         Meeting place is Building 1 ground floor Elevator Lobby. Please note that to access above ceiling, contractors must fill out above ceiling permit in SLA 001-02, have containment cart, and proper PPE to be in an asbestos area).\nRFIs are due on 06/26/2026 at 2:00 PM EST email to David.hernandez1@va.gov \nQuotes due date has been changed to: 07/14/2026 at 2:00PM EST email to David.hernandez1@va.gov","text":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls\nPROJECT NUMBER: 673-21-153\nLOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612\nTHE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION\nCHANGES:\nProvide copies of Drawings, Specifications, and other documents\nUpdated Wage Determination\nAnswers to RFIs\nAdding VAAR clause 852.204-70 and 852.204-72; FAR 52.222-90\n2 sites visit to review the above ceiling inspections have been scheduled for\n06/24/2026 at 0530 EST\n06/24/2026 at 1900 EST\nMeeting place is Building 1 ground floor Elevator Lobby. Please note that to access above ceiling, contractors must fill out above ceiling permit in SLA 001-02, have containment cart, and proper PPE to be in an asbestos area).\nRFIs are due on 06/26/2026 at 2:00 PM EST email to David.hernandez1@va.gov\nQuotes due date has been changed to: 07/14/2026 at 2:00PM EST email to David.hernandez1@va.gov","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T21:01:36.253Z","created_at":"2026-07-09T20:49:48.818Z","modified_at":"2026-07-10T11:23:22.862Z","response_deadline":{"raw":"2026-07-24T13:00:00-04:00","utc":"2026-07-24T17:00:00Z","date":"2026-07-24","time":"13:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b4995cfb5ccf409e889da7b46fb84aa1/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-12-13","archive_type":"auto_custom"},"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"b4995cfb5ccf409e889da7b46fb84aa1","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:18:35.197811481Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"81c3ae9a30d5fc1d87b68692cb4e916b1cf0faa5116ae75c471ee9a29cba5101","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"<p>PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612 THE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION CHANGES: Answers to RFIs,&nbsp;Updated SOW, updated Drawings, update Specs, second Site visit signing sheet, structural drawings, bdg1 life safety,&nbsp;Tampa ground Floor Map, Plumbing and electrical .Add Clauses FAR 52.223-2 and 52.223-23 to Solicitation.&nbsp;POP is updated to 730-calendar days after NTP.</p>\n\n<p>Quotes due date has been changed to: 07/24/2026 at 1:00PM EST email to David.hernandez1@va.gov</p>","text":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612 THE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION CHANGES: Answers to RFIs, Updated SOW, updated Drawings, update Specs, second Site visit signing sheet, structural drawings, bdg1 life safety, Tampa ground Floor Map, Plumbing and electrical .Add Clauses FAR 52.223-2 and 52.223-23 to Solicitation. POP is updated to 730-calendar days after NTP.\n\nQuotes due date has been changed to: 07/24/2026 at 1:00PM EST email to David.hernandez1@va.gov","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"dates":{"posted":"2026-07-10","posted_at":"2026-07-10T11:23:22.862Z","created_at":"2026-07-10T11:19:54.039Z","modified_at":"2026-07-10T11:23:22.865Z","response_deadline":{"raw":"2026-07-24T13:00:00-04:00","utc":"2026-07-24T17:00:00Z","date":"2026-07-24","time":"13:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/13231759ae574efca3262a0f7cb985d1/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-12-13","archive_type":"auto_custom"},"history":[{"index":10,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":9,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T21:01:36.253Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b4995cfb5ccf409e889da7b46fb84aa1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":7,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T16:54:44.001Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634","solicitation_number":"36C24826Q0451"},{"index":6,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T19:20:48.932Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"2e79fc68a47749059be0b149e91baaa6","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":5,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-16T19:05:15.359Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6291e62d78434076aa9749ab19559b65","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6"},{"index":4,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T18:24:47.372Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c639e4817c5745d7beaa2d91026fcc16","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":3,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:24:30.271Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a295abe76d8947f699c16cf67e4e31e3","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"},{"index":2,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-04-01T11:15:16.222Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","solicitation_number":"36C24826Q0451","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"David M Hernandez","role":"primary","email":"David.Hernandez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"13231759ae574efca3262a0f7cb985d1","lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:09:54.694100361Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"a54e56acb29696374c5f5833105ba0ffca2827f3e83d70cc687804496975f9a3","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"<p>PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612 THE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION CHANGES: Answers to RFIs,&nbsp;Updated SOW, updated Drawings, update Specs, second Site visit signing sheet, structural drawings, bdg1 life safety,&nbsp;Tampa ground Floor Map, Plumbing and electrical .Add Clauses FAR 52.223-2 and 52.223-23 to Solicitation.&nbsp;POP is updated to 730-calendar days after NTP.</p>\n\n<p>Quotes due date has been changed to: 07/24/2026 at 1:00PM EST email to David.hernandez1@va.gov</p>","text":"PROJECT TITLE: BB Renovate Ground Floor Halls and Walls PROJECT NUMBER: 673-21-153 LOCATION: James A. Haley VA Hospital, 13000 Bruce B. Downs Boulevard, Tampa, Florida, 33612 THE PURPOSE OF THIS AMENDMENT IS TO PROVIDE THE FOLLOWING INFORMATION CHANGES: Answers to RFIs, Updated SOW, updated Drawings, update Specs, second Site visit signing sheet, structural drawings, bdg1 life safety, Tampa ground Floor Map, Plumbing and electrical .Add Clauses FAR 52.223-2 and 52.223-23 to Solicitation. POP is updated to 730-calendar days after NTP.\n\nQuotes due date has been changed to: 07/24/2026 at 1:00PM EST email to David.hernandez1@va.gov","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0451","product_service_code":"Z2DA"},{"award":{"date":"2026-10-08","amount":"10720445.00","number":"36C24827C0004","awardee":{"raw":"NAPC & HSCC JV LLC SEMINOLE 33772 FLK","uei":"CSB6Z5LBPR99","cage":"7PYV9","name":"NAPC & HSCC JV LLC","location":{"zip":"33772","city":{"name":"SEMINOLE"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"dates":{"posted":"2026-10-08","posted_at":"2026-10-08T18:41:22.994Z","award_date":"2026-10-08","created_at":"2026-10-08T18:41:20.739Z","modified_at":"2026-10-08T18:41:22.994Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/c76bc30c8f604a809cdaf6ce7c80fab8/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-07","archive_type":"auto_custom"},"history":[{"index":2,"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T18:41:22.994Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"c76bc30c8f604a809cdaf6ce7c80fab8","solicitation_number":"36C24826Q0451","related_opportunity_id":"13231759ae574efca3262a0f7cb985d1"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"DAVID HERNANDEZ","role":"primary","email":"DAVID.HERNANDEZ1@VA.GOV","phone":"813-893-3904","title":"CONTRACTING SPECIALIST"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"c76bc30c8f604a809cdaf6ce7c80fab8","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T01:00:31.817101662Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"457404c503b11551171b0d06c9ceabaa804e7b5942386d7c402dd4ba5f95741e","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-09T04:25:46.346911714Z"},"description":{"html":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","text":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24826Q0451","place_of_performance":{"zip":"33612","city":{"code":"71000","name":"Tampa"},"state":{"code":"FL","name":"Florida"},"street":"JAHVAMC 13000 BRUCE B. DOWNS BLVD","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2DA"},{"award":{"date":"2026-10-08","amount":"10720445.00","number":"36C24827C0004","awardee":{"raw":"NAPC & HSCC JV LLC SEMINOLE 33772 FLK","uei":"CSB6Z5LBPR99","cage":"7PYV9","name":"NAPC & HSCC JV LLC","location":{"zip":"33772","city":{"name":"SEMINOLE"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"dates":{"posted":"2026-10-08","posted_at":"2026-10-08T18:41:23.582Z","award_date":"2026-10-08","created_at":"2026-10-08T18:41:21.364Z","modified_at":"2026-10-08T18:41:23.582Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/ccef57f1430a481ca9bdfd7bc09247f7/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-07","archive_type":"auto_custom"},"history":[{"index":2,"title":"Z2DA-- FY27 NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-08T18:41:23.582Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"ccef57f1430a481ca9bdfd7bc09247f7","solicitation_number":"36C24826Q0451","related_opportunity_id":"13231759ae574efca3262a0f7cb985d1"},{"index":1,"title":"Z2DA--FY26: NRM (PROJ 673-21-153) BB Renovate Ground Floor Halls and Walls","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-10T11:23:22.862Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"13231759ae574efca3262a0f7cb985d1","solicitation_number":"36C24826Q0451","parent_opportunity_id":"08a6d65ea8fa4da986af300bbe164ef6","related_opportunity_id":"f2b49f4b6b9548a993a4a25d5b0d9634"}],"contacts":[{"name":"DAVID HERNANDEZ","role":"primary","email":"DAVID.HERNANDEZ1@VA.GOV","phone":"813-893-3904","title":"CONTRACTING SPECIALIST"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ccef57f1430a481ca9bdfd7bc09247f7","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"08a6d65ea8fa4da986af300bbe164ef6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T01:01:18.820614255Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"49eabdcdf0a96ec87d2e4bca02a0253e2514d1ba7394baa370ed7a45f36378fa","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-09T04:25:46.346911714Z"},"description":{"html":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","text":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24826Q0451","place_of_performance":{"zip":"33612","city":{"code":"71000","name":"Tampa"},"state":{"code":"FL","name":"Florida"},"street":"JAHVAMC 13000 BRUCE B. DOWNS BLVD","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2DA"}],"due_at":"2026-07-24T17:00:00Z","due_date":"2026-07-24","closes_at":"2026-07-24T17:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","state":"FL","county":"12057","county_name":"Hillsborough County","city":"1271000","city_name":"Tampa","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"CSB6Z5LBPR99","amount":"10720445.00","linked_awards":10,"cancelled":false,"archived":true,"updated_at":"2026-11-08T06:19:51.342696Z","principal_notice_id":"ccef57f1430a481ca9bdfd7bc09247f7","description":{"text":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","html":"ITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nJB\n$10,720,445.00\n$10,720,445.00\n\nThis project scope shall include but not be limited to the renovation of the halls and walls on the ground floor of building 1 at the James A. Haley VA hospital, located at 13000 Bruce B. Downs boulevard, Tampa, Florida as required by the drawings and specifications included in this acquisition package. The scope of work includes asbestos abatement and the replacement of flooring, ceilings, doors, hardware, light fixtures, crash rails, handrails, drinking fountains and miscellaneous elements that are directly related to the hallways. This work shall include but not be limited to architectural, mechanical, plumbing, electrical, and abatement.\n\nContract Period: Base\nPOP Begin: 10/10/2026\nPOP End: 10-13-2028\nPRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction\nPRODUCT/SERVICE CODE: Z2DA - Repair or Alteration of Hospitals and Infirmaries","origin":"detail"},"contacts":[{"name":"DAVID HERNANDEZ","role":"primary","email":"DAVID.HERNANDEZ1@VA.GOV","phone":"813-893-3904","title":"CONTRACTING SPECIALIST"}],"place_of_performance":{"zip":"33612","city":{"code":"71000","name":"Tampa"},"state":{"code":"FL","name":"Florida"},"street":"JAHVAMC 13000 BRUCE B. DOWNS BLVD","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"naics_codes":["236220"],"award":{"date":"2026-10-08","amount":"10720445.00","number":"36C24827C0004","awardee":{"raw":"NAPC & HSCC JV LLC SEMINOLE 33772 FLK","uei":"CSB6Z5LBPR99","cage":"7PYV9","name":"NAPC & HSCC JV LLC","location":{"zip":"33772","city":{"name":"SEMINOLE"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"attachments":[{"resource_id":"92391338b5ff41a0a1d2f65a5b816d18","name":"36C24826Q0451.docx","kind":"file","mime_type":".docx","size_bytes":35779,"posted_at":"2026-03-16T16:54:44.001Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/92391338b5ff41a0a1d2f65a5b816d18/download","mirrored":false},{"resource_id":"7f593b3451704a9db3347a7c732b317c","name":"36C24826Q0451_1.docx","kind":"file","mime_type":".docx","size_bytes":160362,"posted_at":"2026-04-01T11:15:16.222Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7f593b3451704a9db3347a7c732b317c/download","mirrored":false},{"resource_id":"265871f58ec14f0cb8d1346406c0ca81","name":"36C24827C0004_1.docx","kind":"file","mime_type":".docx","size_bytes":24932,"posted_at":"2026-10-08T18:41:23.582Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/265871f58ec14f0cb8d1346406c0ca81/download","mirrored":false},{"resource_id":"f73332e43a764d5da534f381d654481f","name":"36C24827C0004_1.docx","kind":"file","mime_type":".docx","size_bytes":24932,"posted_at":"2026-10-08T18:41:22.994Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f73332e43a764d5da534f381d654481f/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24827C0004_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24827C0004_3600_-NONE-_-NONE-/","piid":"36C24827C0004","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"CSB6Z5LBPR99","recipient_name":"NAPC & HSCC JV LLC","recipient_uei":"CSB6Z5LBPR99","recipient_cage":"7PYV9","recipient_city":"SEMINOLE","recipient_state":"FL","sub_name":"Department of Veterans Affairs","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","office_key":"o-36C248","first_action_date":"2026-10-08","last_action_date":"2026-10-13","actions":2,"obligated":"10720445.00","current_total_value":"10720445.00","potential_total_value":"10720445.00","naics":"236220","psc":"Z2DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":6,"description":"RENOVATE GROUND FLOOR HALLS AND WALLS","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24826Q0451 equals the FPDS solicitation identifier","same awarding office 36C248"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24827Q0064","latest_notice_id":"e329bedb2ef343a0a873de413cf31d24","title":"V231--Hoptel Services Gainesville","solicitation_number":"36C24827Q0064","notice_type":"o","first_type":"p","first_posted":"2026-11-06","last_posted":"2026-11-19","notices":7,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"721110","psc":"V231","set_aside":"SBA","state":"FL","county":"12001","county_name":"Alachua County","city":"1225175","city_name":"Gainesville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24827Q0051","latest_notice_id":"d56f5324e7874602ba56b5268afbad47","title":"J065--Neptune Rover Medical Surgical Maintenance Base plus Four (4) Option Years","solicitation_number":"36C24827Q0051","notice_type":"o","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J065","set_aside":null,"state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T07:01:08.699328Z"},{"key":"36C24827Q0155","latest_notice_id":"831665dca3fc431482f486284606c5a5","title":"J026--Pneumatic Tube System Preventive Maintenance","solicitation_number":"36C24827Q0155","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238290","psc":"J026","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24827Q0143","latest_notice_id":"06bab5721d954ba4a41ceb4b0ae7266c","title":"H199--FY27 Cathodic Protection Inspection and Testing","solicitation_number":"36C24827Q0143","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"541380","psc":"H199","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"}],"similar_open":[{"key":"HARBSS202701","latest_notice_id":"22963d82312349a99befea586884297c","title":"Outdoor Fitness Facility, Building 389— Supply, Delivery, and Limited Installation Support","solicitation_number":"HARBSS-2027-01","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA6648","office_name":"FA6648 482 LSS LGC","naics":"236220","psc":"5670","set_aside":null,"state":"FL","county":"12086","county_name":"Miami-Dade County","city":"1232275","city_name":"Homestead","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N6945027RH140","latest_notice_id":"fbe79c7a8c9142a4871ef92b4bc3e9f0","title":"HANGAR 140 RENOVATIONS AT NAVAL AIR STATON (NAS) JACKSONVILLE (JAX), JACKSONVILLE, FLORIDA","solicitation_number":"N6945027RH140","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-19","notices":5,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N69450","office_name":"NAVFACSYSCOM SOUTHEAST","naics":"236220","psc":"Z2JZ","set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FA664827R0001","latest_notice_id":"7e7667761a8c401eb59ba40df103975d","title":"Design-Build Renovation of Building 164, Outdoor Recreation Center, Homestead Air Reserve Base, Florida","solicitation_number":"FA664827R0001","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-11-17","notices":7,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA6648","office_name":"FA6648 482 LSS LGC","naics":"236220","psc":"Y1AZ","set_aside":null,"state":"FL","county":"12086","county_name":"Miami-Dade County","city":"1232275","city_name":"Homestead","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Homestead Air Reserve Base","site_key":"homestead-air-reserve-base-fl","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":194,"indexable":false}