Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,557 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Special notice

Intent to Sole Source | Calibrate Air Flow Monitoring Stations

36C24826Q0097

Department of Veterans Affairs, 248-Network Contract Office 8. Plumbing, Heating, and Air-Conditioning Contractors.

Awarded

Johnson Controls, Inc.

$203,530.02 obligated so far on USAspending

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one was awarded in 2025

57 like it are open now in plumbing, heating, and air-conditioning contractors

All 57 open in plumbing, heating, and air-conditioning contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary
How it ended
Awarded to Johnson Controls, Inc. on November 28, 2025. The contracting office reported 1 offer (not competed).

Description

As published on SAM.gov.

Network Contracting Office 8 (NCO 8) intends to make a sole source award to Johnson Controls under the authority of FAR 6.302-1, when the supplies or services required by the agency are available from only one responsible source. Market research was conducted and determined that Johnson Controls is the only vendor capable of providing supplies and services necessary to meet the requirements. The proposed contract action is to support the Bay Pines VA Healthcare System, for the Calculation and Calibration (CaC) of up to 50 Air Flow Monitoring Stations (AFMS) and up to 175 AFMS probes. These services are required to ensure accurate airflow measurement and integration with the existing METASYS Building Automation System (BAS) installed at the Bay Pines VA Medical Center in support of the Lee County VA Medical Center, 2489 Diplomat Parkway East, Cape Coral, FL 33909. This one-time contract will be firm-fixed priced. BRAND ONLY GENERAL: The Contractor shall supply all supervision, materials, and labor to make the necessary Heating, Ventilation, and Air Conditioning (HVAC) Air Flow Monitoring Station (AFMS) system calculations and calibrations (CaC) to include including sensors, pickup tubes, pressure transducers, temperature sensors, and the AFMS controller, following manufacturer's specifications and best practices at the Lee County Health Care Clinic. SCOPE: Preform a whole building adjustment, testing and commissioning to the HVAC Air flow monitoring station (AFMS) system through providing Calculation and Calibration (CaC) on up to qty 50 (Fifty) AFMS and up to 175 AFMS probes. Calculate and calibrate the airflow in each Air Handling Units (AHU) to manufactures recommendation and optimum airflow operation. Procure and install the new air flow monitoring station and its components, including sensors, transmitter, and controller. Remove old, nonfunctioning items and install the new airflow monitoring station components, including sensors, pickup tubes, pressure transducers, temperature sensors, and the AFMS controller, following manufacturer's specifications and best practices. Connect the new system to the existing METASY Building Automation System (BAS), for data collection and integration. Re-torque electrical and power connections as needed. Ensure the station and its components are compatible with the excising Building Management System (BMS) or control system. Verify proper operation of the new airflow monitoring station and its components in manual, auto, and bypass modes. Conduct functional checks prior to verify system is functioning as designed and perform system commissioning. Run tests to ensure equipment is operating according to design parameters, including safety and emergency control devices. Configure alarm settings to notify of deviations from airflow setpoints or other critical parameters. Submit a written report containing all recorded test data and proper equipment operation. This Notice of Intent is not a request for Proposals or Quotations. No solicitation document exists, and no telephone or email inquiries will be accepted. No contract award will be made on the basis of proposals, or quotations received in response to this notice. This is strictly for market research purposes. Interested persons may identify their interest and capability to respond to the requirement and should furnish detailed data concerning their capabilities to provide supplies/services sought including pricing data and technical data sufficient enough to determine that a comparable source to the government is available. The government may consider all Expressions of Interest (EOI) received prior to November 26, 2025, at 12:30 PM EST. A determination by the government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Responses to this notice must be emailed to Lakiesha.anderson@va.gov using the following title in the email s subject line: 36C24826Q0097 Calibrate Air Flow Monitoring Stations and received by 12:30PM EST on November 26,2025. Submitters are responsible for ensuring their EOI reaches the designated contracting officer on time.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
CE8MGXAS9KJ6
CAGE
32242
Vendor location
Milwaukee, WI
Contract
36C24826P0204, purchase order
Obligated
$203,530.02
Actions
1 between November 28, 2025 and November 28, 2025
Competition
Not Competed, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Calibrate Airflow Monitoring
Match
solicitation number 36C24826Q0097 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. November 12, 2025

    Special notice

    Due November 26, 2025 at 12:30 PM EST. SAM.gov, notice 44b19e0890224c41bc0370ab332d6b6f

    1 revision on SAM
    • November 12, 2025: publish, special notice

Points of contact