{"canonical":"https://sealedbidder.com/opportunities/36c24826q0032","key":"36C24826Q0032","url":"https://sealedbidder.com/opportunities/36c24826q0032","title":"J065--FY27 Option Year 1 Mod Draeger Anesthesia System Maintenance","solicitation_number":"36C24826Q0032","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-20T19:00:00Z","first_posted":"2025-10-29","last_posted":"2026-10-21","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J065","set_aside":null,"place_state":"FL","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"12103","place_county_name":"Pinellas County","place_city":"1204200","place_city_name":"Bay Pines","winner":"DRAEGER INC","award_amount":"0","publications":[{"notice_id":"35cf348cb4a743e680fe0477d5ea1c56","title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","solicitation_number":"36C24826Q0032","notice_type":"s","base_type":"s","posted":"2025-10-29","posted_at":"2025-10-29T15:56:06.777Z","due_at":"2025-11-06T19:00:00Z","due_date":"2025-11-06","cancelled":false,"archived":true,"archive_date":"2025-11-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/35cf348cb4a743e680fe0477d5ea1c56/view","enriched":true,"history":[{"index":6,"title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T15:56:06.777Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56","solicitation_number":"36C24826Q0032"},{"index":4,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}]},{"notice_id":"80c06e8aca7443f3927f6a1c1d9815b4","title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","solicitation_number":"36C24826Q0032","notice_type":"r","base_type":"s","posted":"2025-10-30","posted_at":"2025-10-30T18:15:36.800Z","due_at":"2025-11-04T19:00:00Z","due_date":"2025-11-04","cancelled":false,"archived":true,"archive_date":"2025-11-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/80c06e8aca7443f3927f6a1c1d9815b4/view","enriched":true,"history":[{"index":8,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T15:56:06.777Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56","solicitation_number":"36C24826Q0032"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}]},{"notice_id":"367befefc83149d8a50dfdbb8e171f1d","title":"J065--FY26: Draeger Anesthesia System Maintenance","solicitation_number":"36C24826Q0032","notice_type":"p","base_type":"r","posted":"2025-11-05","posted_at":"2025-11-05T17:09:45.687Z","due_at":"2025-11-20T19:00:00Z","due_date":"2025-11-20","cancelled":false,"archived":true,"archive_date":"2025-11-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/367befefc83149d8a50dfdbb8e171f1d/view","enriched":true,"history":[{"index":9,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}]},{"notice_id":"69cc3d029f5b41209809881324d56f29","title":"J065--FY26: Draeger Anesthesia System Maintenance","solicitation_number":"36C24826Q0032","notice_type":"o","base_type":"p","posted":"2025-11-07","posted_at":"2025-11-07T20:09:15.566Z","due_at":"2025-11-20T19:00:00Z","due_date":"2025-11-20","cancelled":false,"archived":true,"archive_date":"2025-11-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/69cc3d029f5b41209809881324d56f29/view","enriched":true,"history":[{"index":9,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-25T18:02:40.252Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"df1b8571a20a4e878c63049b2e716554","solicitation_number":"36C24826Q0032","related_opportunity_id":"69cc3d029f5b41209809881324d56f29"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"}]},{"notice_id":"df1b8571a20a4e878c63049b2e716554","title":"J065--FY26: Draeger Anesthesia System Maintenance","solicitation_number":"36C24826Q0032","notice_type":"a","base_type":"o","posted":"2025-11-25","posted_at":"2025-11-25T18:02:40.252Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-12-10","removed_at":null,"award_number":"36C24826P0193","awardee_name":"DRAEGER INC","amount":"82583.65","link_sam":"https://sam.gov/workspace/contract/opp/df1b8571a20a4e878c63049b2e716554/view","enriched":true,"history":[{"index":6,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-25T18:02:40.252Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"df1b8571a20a4e878c63049b2e716554","solicitation_number":"36C24826Q0032","related_opportunity_id":"69cc3d029f5b41209809881324d56f29"},{"index":4,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"}]},{"notice_id":"d0b5fcee9dd1455ab38819f897896eac","title":"J065--FY27 Option Year 1 Mod Draeger Anesthesia System Maintenance","solicitation_number":"36C24826Q0032","notice_type":"a","base_type":"a","posted":"2026-10-21","posted_at":"2026-10-21T14:10:55.179Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-11-05","removed_at":null,"award_number":"36C24826P0193P00002","awardee_name":"DRAEGER INC","amount":"0","link_sam":"https://sam.gov/workspace/contract/opp/d0b5fcee9dd1455ab38819f897896eac/view","enriched":true,"history":[{"index":1,"title":"J065--FY27 Option Year 1 Mod Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-21T14:10:55.179Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"d0b5fcee9dd1455ab38819f897896eac","solicitation_number":"36C24826Q0032"}]}],"latest_notice_id":"d0b5fcee9dd1455ab38819f897896eac","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-10-29","posted_at":"2025-10-29T15:56:06.777Z","created_at":"2025-10-29T15:56:04.527Z","modified_at":"2025-11-17T05:00:07.932Z","response_deadline":{"raw":"2025-11-06T14:00:00-05:00","utc":"2025-11-06T19:00:00Z","date":"2025-11-06","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/35cf348cb4a743e680fe0477d5ea1c56/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-16","archive_type":"auto_custom"},"history":[{"index":6,"title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T15:56:06.777Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56","solicitation_number":"36C24826Q0032"},{"index":4,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"35cf348cb4a743e680fe0477d5ea1c56","lineage_id":"80c06e8aca7443f3927f6a1c1d9815b4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T03:11:04.282586587Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"1075fb32ac267412c42d0920edc3f63cd12a8930d6675ad263149a201b172147","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-24T03:11:04.282586587Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"NOTICE OF INTENT TO SOLE SOURCE: This notice is being published in accordance with Federal Acquisition Regulation (FAR) Subpart 5.101 requiring dissemination of information for proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive quotes/proposals. The statutory authority for this sole source procurement is prescribed by FAR 13.501(a). The Department of Veterans Affairs intends to issue a base plus two (2) option year (one 12-month base year; and two 12-month option years); firm fixed prices; sole source award contract to Draeger, Inc. However, all responsible sources may submit a capability statement demonstrating the ability to provide the services requested, which shall be considered by the agency before the intended award date. Interested sources who submit data are responsible for appropriately marking information if it is proprietary in nature. \nThe Government shall not reimburse interested sources for any information provided. No requests for capability briefings will be honored. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Interested vendors must respond to this notice on or before November 06, 2025, at 2:00 pm Eastern Time by sending an email to michael.shook@va.gov. NAICS Code: 811210 - Other Electronic and Precision Equipment Repair and Maintenance. Background: The HEALTHCARE TECHNOLOGY MGMT SVC department requests the technical services of OEM authorized technicians and maintenance personnel to perform preventative maintenance of the Anesthesia machines currently in use at the Bay Pines VA Healthcare facility. PURPOSE: Contractor is required to provide labor, transportation, supervision, and parts to repair the highly technical medical equipment listed above. \nThis continuous service is required to maintain the system(s) mentioned above in required operating conditions, according to the manufacturer s specifications. TECHNICAL REQUIREMENTS: Bay Pines VA Healthcare facility requires full-service coverage of the Draeger Medical Anesthesia units at the Bay Pines VA Medical Center. Draeger Medical, INC is the sole distributor of the units below: a) Draeger D-Vapor 2000, the b)Fabius Tiro with Cosy 2.6. c)Perseus A500. d)Vapor 2000 iso & Sevo units. On-site service and support by factory-trained, certified field service engineers. \nOnsite response within three business days from the time the call is logged with Tech Support. On-Site Service Hours Coverage: Standard 8 am-5 pm coverage during local standard time. Phone Support Center: Standard 7 am-7 pm CST phone cover","text":"NOTICE OF INTENT TO SOLE SOURCE: This notice is being published in accordance with Federal Acquisition Regulation (FAR) Subpart 5.101 requiring dissemination of information for proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive quotes/proposals. The statutory authority for this sole source procurement is prescribed by FAR 13.501(a). The Department of Veterans Affairs intends to issue a base plus two (2) option year (one 12-month base year; and two 12-month option years); firm fixed prices; sole source award contract to Draeger, Inc. However, all responsible sources may submit a capability statement demonstrating the ability to provide the services requested, which shall be considered by the agency before the intended award date. Interested sources who submit data are responsible for appropriately marking information if it is proprietary in nature.\nThe Government shall not reimburse interested sources for any information provided. No requests for capability briefings will be honored. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Interested vendors must respond to this notice on or before November 06, 2025, at 2:00 pm Eastern Time by sending an email to michael.shook@va.gov. NAICS Code: 811210 - Other Electronic and Precision Equipment Repair and Maintenance. Background: The HEALTHCARE TECHNOLOGY MGMT SVC department requests the technical services of OEM authorized technicians and maintenance personnel to perform preventative maintenance of the Anesthesia machines currently in use at the Bay Pines VA Healthcare facility. PURPOSE: Contractor is required to provide labor, transportation, supervision, and parts to repair the highly technical medical equipment listed above.\nThis continuous service is required to maintain the system(s) mentioned above in required operating conditions, according to the manufacturer s specifications. TECHNICAL REQUIREMENTS: Bay Pines VA Healthcare facility requires full-service coverage of the Draeger Medical Anesthesia units at the Bay Pines VA Medical Center. Draeger Medical, INC is the sole distributor of the units below: a) Draeger D-Vapor 2000, the b)Fabius Tiro with Cosy 2.6. c)Perseus A500. d)Vapor 2000 iso & Sevo units. On-site service and support by factory-trained, certified field service engineers.\nOnsite response within three business days from the time the call is logged with Tech Support. On-Site Service Hours Coverage: Standard 8 am-5 pm coverage during local standard time. Phone Support Center: Standard 7 am-7 pm CST phone cover","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24826Q0032","product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2025-10-30","posted_at":"2025-10-30T18:15:36.800Z","created_at":"2025-10-30T18:15:34.490Z","modified_at":"2025-11-15T04:55:46.390Z","response_deadline":{"raw":"2025-11-04T14:00:00-05:00","utc":"2025-11-04T19:00:00Z","date":"2025-11-04","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/80c06e8aca7443f3927f6a1c1d9815b4/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-14","archive_type":"auto_custom"},"history":[{"index":8,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance Notice of intent to sole source","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-29T15:56:06.777Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56","solicitation_number":"36C24826Q0032"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"80c06e8aca7443f3927f6a1c1d9815b4","lineage_id":"80c06e8aca7443f3927f6a1c1d9815b4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T02:46:58.568408334Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"8d1575a310eb24b02299a6e9832df97ecfd1697b22ba560737323234104d8045","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-24T02:46:58.568408334Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Good day, SDVOSB s, VOSB s & SB's & LB s\nThis Sources Sought is issued solely for informational and planning purposes only.Â  It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified businesses.Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â  If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete. If not enough qualified and capable small business responses are received, an unrestricted solicitation may occur in which instance all capable and qualified venders may respond from any socioeconomic category.\nPlease direct reply in the affirmative via email if you are interested and can provide the required product/service and proof of authorized servicing capabilities on the specific equipment listed for this requirement. Please provide your capability statement,Â  I will accept responses for this Sources Sought until the 4th of November 2025 14:00 EDT, thanks.\n1.General: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines.  The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.  \n\n2.SCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below.  The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.  \n\nThe initial period of performance is from December 5, 2025, through December 4, 2026.  This action shall be a firm-fixed price award one base year (1) and (2) option year periods.  The Contractor shall include advanced pricing for each machine for each option period in their initial quote. Below is a list of equipment used at 10,000 Bay Pines BLVD., Bay Pines, FL 33744 for life-support during surgeries: \n\n\nEE #\nModel\nSerial\n51081\nFABIUS TIRO\nARYE-0062\n89133\nFABIUS TIRO\nASDM-0118\n90861\nFABIUS TIRO\nASEH-0093\n130809\nFABIUS TIRO\nASLK-0148\n174782\nFABIUS TIRO\nASSL-0002\n157900\nPERSEUS A500\nASPL-0137\n157901\nPERSEUS A500\nASPL-0138\n157902\nPERSEUS A500\nASPL-0139\n157903\nPERSEUS A500\nASPL-0140\n157904\nPERSEUS A500\nASPL-0142\n157905\nPERSEUS A500\nASPM-0059\n157906\nPERSEUS A500\nASPM-0063\n157907\nPERSEUS A500\nASPM-0064\n157908\nPERSEUS A500\nASPM-0065\n157909\nPERSEUS A500\nASPM-0066\n157910\nPERSEUS A500\nASPM-0067\n157911\nPERSEUS A500\nASPM-0068\n157912\nPERSEUS A500\nASPM-0069\n157913\nPERSEUS A500\nASPM-0070\n74576\nD-VAPOR\nASBF-0172\n88436\nD-VAPOR\nASEC-0310\n88438\nD-VAPOR\nASEC-0312\n88440\nD-VAPOR\nASEC-0314\n88441\nD-VAPOR\nASEC-0315\n88443\nD-VAPOR\nASEC-0317\n88444\nD-VAPOR\nASEC-0318\n88445\nD-VAPOR\nASEC-0319\n88446\nD-VAPOR\nASEC-0320\n88447\nD-VAPOR\nASEC-0321\n88448\nD-VAPOR\nASEC-0322\n88449\nD-VAPOR\nASEC-0323\n88450\nD-VAPOR\nASEC-0324\n88451\nD-VAPOR\nASEC-0325\n88452\nD-VAPOR\nASEC-0326\n88454\nD-VAPOR\nASEC-0328\n133704\nD-VAPOR\nASMA-1453\n158388\nD-VAPOR\nASPL-0093\n88410\nVAPOR 2000\nASEC-0126\n88411\nVAPOR 2000\nASEC-0127\n88416\nVAPOR 2000\nASEC-0631\n88418\nVAPOR 2000\nASEC-0633\n88419\nVAPOR 2000\nASEC-0634\n88420\nVAPOR 2000\nASEC-0635\n88421\nVAPOR 2000\nASEC-0636\n88422\nVAPOR 2000\nASEC-0637\n88423\nVAPOR 2000\nASEC-0638\n88424\nVAPOR 2000\nASEC-0639\n88425\nVAPOR 2000\nASEC-0640\n88426\nVAPOR 2000\nASEC-0671\n88427\nVAPOR 2000\nASEC-0672\n88428\nVAPOR 2000\nASEC-0673\n88430\nVAPOR 2000\nASEC-0676\n88431\nVAPOR 2000\nASEC-0677\n88433\nVAPOR 2000\nASEC-0679\n88435\nVAPOR 2000\nASEC-0692\n96452\nVAPOR 2000\nARXC-0017\n96453\nVAPOR 2000\nARWB-1133\n96455\nVAPOR 2000\nARYD-0171\n96457\nVAPOR 2000\nARWD-0028\n96458\nVAPOR 2000\nARWB-1164\n113046\nVAPOR 2000\nASDM-0011\n113047\nVAPOR 2000\nASDM-0012\n113048\nVAPOR 2000\nASDM-0013\n113049\nVAPOR 2000\nASDM-0014\n133705\nVAPOR 2000\nASMA-0196\n158386\nVAPOR 2000\nASPL-0893 \n158387\nVAPOR 2000\nASPL-0675\n187329\nVAPOR 2000\nASUE-0263\n187330\nVAPOR 2000\nASUE-0262\n187331\nVAPOR 2000\nASUE-0265\n187332\nVAPOR 2000\nASUE-0261\n187333\nVAPOR 2000\nASUE-0264\n\nThe following is a list of equipment used at 2489 Diplomat Parkway East, Cape Coral, FL 33909 for life-support during surgeries:\n\nEE #\nModel\nSerial\n182453\nFABIUS TIRO\nASTL-0003\n157917\nPERSEUS A500\nASPL-0141\n157915\nPERSEUS A500\nASPM-0060\n157914\nPERSEUS A500\nASPM-0061\n157916\nPERSEUS A500\nASPM-0062\n88437\nD-VAPOR\nASEC-0311\n88439\nD-VAPOR\nASEC-0313\n88442\nD-VAPOR\nASEC-0316\n88453\nD-VAPOR\nASEC-0327\n182458\nD-VAPOR\nASTK-0101\n88412\nVAPOR 2000\nASEC-0128\n88417\nVAPOR 2000\nASEC-0632\n88429\nVAPOR 2000\nASEC-0674\n88432\nVAPOR 2000\nASEC-0678\n88434\nVAPOR 2000\nASEC-0680\n98216\nVAPOR 2000\nASDM-0127\n98217\nVAPOR 2000\nASDM-0126\n98218\nVAPOR 2000\nASDM-0137\n182454\nVAPOR 2000\nASTK-1050\n182457\nVAPOR 2000\nASTL-0215\n\n3.GENERAL REQUIREMENTS: Service  \n\nThe contractor shall provide only Draeger trained and certified field service engineers (FSE).  The FSE shall be equipped with licensed Draeger maintenance utility software.  All FSE maintenance shall be performed in accordance with current Draeger procedures and at Drager recommended frequencies.  \n\nAll maintenance will be performed during extended VA business hours, 7:00 AM - 8:00 PM, Monday-Friday, except Federal Holidays, unless otherwise specified. Contractor may work outside normal business hours by arrangement with Contracting Officer s Representative (COR) if such services are provided without additional charge to the government.  Any overtime charges must be approved by the Contracting Officer if not included in the contract pricing schedule.  COR must notify the Contracting Officer before authorizing overtime work.\n\nThe contractor shall provide emergency repair service 24 hours a day, 7 days a week.\n\nThe VA shall not provide service manuals or service diagnostic software to the contractor.  The contractor shall obtain, have on file, and make available to its Field Service Engineers (FSEs) all operational and technical documentation (e.g., operational and service manuals, schematics, and parts lists) which are necessary to meet the performance requirements of the contract.  The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the COR upon request.  Any charges for parts, manuals, tools, or software required to successfully complete repairs, scheduled maintenance, or certifications shall be included in this contract, and it s agreed upon price.\n\nAll removable media materials (laptop, DVD/CD, USB drive, etc.) need to be scanned on site with approved anti-virus by OI&T or Biomedical staff and approved for use prior to the start of any work.\nA. Parts\n\nThe Contractor shall provide all replacement parts required to complete repairs and maintenance.  The contractor shall provide and install consumable items, such as sensors, at no additional cost to VA.  All provided parts and software updates must be sourced from Draeger, meeting current manufacturer specifications.  Parts removed (replaced) by the contractor become the property of the contractor.\n\nB. Performance Standards\n\nThe COR will assure Contractor performance in accordance with (IAW) the Performance Standard Metrics.  In an effort to minimize the performance management burden, the government shall use 100 percent inspection(s) as indicated below:\n\nPERFORMANCE STANDARD METRICS\nRequirement\nQuality Standard\n            Action \nSurveillance Method\n1. Contractor provided and utilized procedures and checklists with worksheet originals indicating work performed and actual values obtained provided to the COR at the completion of maintenance.\n100% compliance\nFull payment to Contractor pending completion of this metric.  \n \nRegular reviews, inspection and observation; Contractor notified immediately if non-compliance\n\n\n \n2.   Provided documentation of service performed.  \n100% compliance \nFull payment to Contractor pending completion of this metric.  \n  \nContractor notified immediately if non-compliance\n\n3.   Contractor electrical safety inspection at time of PM\n100% compliance\nFull payment to Contractor pending completion of this metric.  \n\nContractor notified immediately if non-compliance\n\n4.   Equipment functions in conformance with latest Draeger specifications.\n100% compliance\nFull payment to Contractor pending completion of this metric.  \n\nRegular reviews, inspection and observation; Contractor notified immediately if non-compliance\n\n\n\n4.Special Instructions\n\nA. Contractor Check-in\n\nThe contractor's FSE will report to Biomedical Engineering, 1F122-100-BP or 2B191-CC-OPC, prior to performance of service.  All FSEs will be fully credentialed and check in at the facility using the approved credentialing system, currently O.R. TRAX.\n\nB. Documentation\n\nAt the conclusion of each repair or scheduled maintenance visit, the contractor will provide a written service report indicating the date of service, the model, serial number, and location of the equipment serviced, the name of the service representative, the hours worked, and the services performed, and parts replaced.  The reports will be delivered electronically to Biomedical Engineering when work is complete. \n\n5.Terms and Conditions: Inspection of Equipment \n\nAny site visit must be coordinated in advance with COR or Biomedical Engineering, 727-398-6661 x15601, there will be no site visits prior to award.\n\n6. CONTRACTOR EXPERIENCE REQUIREMENTS: Each respondent must have an established business, with an office and full time staff to include a \"fully qualified\" field service engineer (FSE) and a \"fully qualified\" FSE who will serve as backup.  \"Fully qualified\" is based upon completion of all Draeger factory training for the model being services.  The FSE(s) shall be authorized by the contractor to perform the maintenance services.  All work shall be performed by \"fully qualified\" competent FSE(s).  The contractor shall make available written assurance to the competency of their personnel and a list of credentials of approved FSEs for each make and model the contractor services at the VA.  The Contracting Officer Representative (COR) may authenticate the training requirements, request training certificates or credentials from the contractor at any time for any personnel who are servicing or installing any VA equipment.  The CO and/or Contracting Officer's Representative (COR) specifically reserves the right to reject any of the contractor's personnel and refuse them permission to work on the VA equipment.  If subcontractors are used, they must be approved in advance by the CO; the contractor shall submit any proposed change in subcontractor(s) to the CO for approval/disapproval.\n\n7. PRIVACY TRAINING AND CYBER SECURITY AWARENESS TRAINING: The contractor will be required to comply with physical security guidelines by either checking in with the VA Police each time they come on-site to perform contracted services or by obtaining a VA Contractor ID badge from the VA Police.\nContractor may not have access to any VA sensitive information under this contract.\nContractor must be escorted at all times by VA staff or contractor must complete VA Privacy and Information Security Awareness and Rules of Behavior training.\n \n8.Training Requirements: \n1.Services must ONLY be performed by Draeger trained technicians, who have evidence of current factory training on the specific device being serviced (Draeger Ventilation, Anesthesia, Monitor, or Neonatal Device)\n2.Must provide evidence of equipment standards and traceability and final device performance testing that follows and complies with all manufacturer procedural requirements.\n3.Must guarantee that safety inspections performed will comply with all applicable federal, state and regulatory requirements, manufacturer standards, and meet FDA alerts and recall requirements.\n4.Each technician must be certified on the applicable Draeger Ventilation Device prior to performing any service and/or maintenance on Draeger manufactured equipment.\n5.Must provide evidence of recent attendance and successful completion of the Draeger Factory Training Seminars for each product serviced.\n6.Must maintain continuous access to the Draeger Service Connect system, which provides all of the relevant and up-to-date Technical Documentation and information for each of the Draeger products serviced.\n7.Must guarantee execution of all Manufacturer Service Recommendations during each service incident, including the use of ONLY manufacturer planned maintenance and repair parts. (Note: Failure to utilize original manufacturer parts may result in the improper operation of the equipment.)\n8.Must possess the legal rights to propriety equipment diagnostic software. (Note: Failure to utilize the Propriety Software may result in the inability to identify equipment operating parameters and to accurately calibrate the equipment.)\n9.The service technician must have completed training for each specific device by a Draeger Authorized Trainer prior to performing service on said device and provide proof of such prior to contract award.","text":"Good day, SDVOSB s, VOSB s & SB's & LB s\nThis Sources Sought is issued solely for informational and planning purposes only.Â It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future.Â The purpose of this notice is to conduct market research and obtain information from qualified businesses.Â This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible.Â If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete. If not enough qualified and capable small business responses are received, an unrestricted solicitation may occur in which instance all capable and qualified venders may respond from any socioeconomic category.\nPlease direct reply in the affirmative via email if you are interested and can provide the required product/service and proof of authorized servicing capabilities on the specific equipment listed for this requirement. Please provide your capability statement,Â I will accept responses for this Sources Sought until the 4th of November 2025 14:00 EDT, thanks.\n1.General: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines. The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.\n\n2.SCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below. The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.\n\nThe initial period of performance is from December 5, 2025, through December 4, 2026. This action shall be a firm-fixed price award one base year (1) and (2) option year periods. The Contractor shall include advanced pricing for each machine for each option period in their initial quote. Below is a list of equipment used at 10,000 Bay Pines BLVD., Bay Pines, FL 33744 for life-support during surgeries:\n\nEE #\nModel\nSerial\n51081\nFABIUS TIRO\nARYE-0062\n89133\nFABIUS TIRO\nASDM-0118\n90861\nFABIUS TIRO\nASEH-0093\n130809\nFABIUS TIRO\nASLK-0148\n174782\nFABIUS TIRO\nASSL-0002\n157900\nPERSEUS A500\nASPL-0137\n157901\nPERSEUS A500\nASPL-0138\n157902\nPERSEUS A500\nASPL-0139\n157903\nPERSEUS A500\nASPL-0140\n157904\nPERSEUS A500\nASPL-0142\n157905\nPERSEUS A500\nASPM-0059\n157906\nPERSEUS A500\nASPM-0063\n157907\nPERSEUS A500\nASPM-0064\n157908\nPERSEUS A500\nASPM-0065\n157909\nPERSEUS A500\nASPM-0066\n157910\nPERSEUS A500\nASPM-0067\n157911\nPERSEUS A500\nASPM-0068\n157912\nPERSEUS A500\nASPM-0069\n157913\nPERSEUS A500\nASPM-0070\n74576\nD-VAPOR\nASBF-0172\n88436\nD-VAPOR\nASEC-0310\n88438\nD-VAPOR\nASEC-0312\n88440\nD-VAPOR\nASEC-0314\n88441\nD-VAPOR\nASEC-0315\n88443\nD-VAPOR\nASEC-0317\n88444\nD-VAPOR\nASEC-0318\n88445\nD-VAPOR\nASEC-0319\n88446\nD-VAPOR\nASEC-0320\n88447\nD-VAPOR\nASEC-0321\n88448\nD-VAPOR\nASEC-0322\n88449\nD-VAPOR\nASEC-0323\n88450\nD-VAPOR\nASEC-0324\n88451\nD-VAPOR\nASEC-0325\n88452\nD-VAPOR\nASEC-0326\n88454\nD-VAPOR\nASEC-0328\n133704\nD-VAPOR\nASMA-1453\n158388\nD-VAPOR\nASPL-0093\n88410\nVAPOR 2000\nASEC-0126\n88411\nVAPOR 2000\nASEC-0127\n88416\nVAPOR 2000\nASEC-0631\n88418\nVAPOR 2000\nASEC-0633\n88419\nVAPOR 2000\nASEC-0634\n88420\nVAPOR 2000\nASEC-0635\n88421\nVAPOR 2000\nASEC-0636\n88422\nVAPOR 2000\nASEC-0637\n88423\nVAPOR 2000\nASEC-0638\n88424\nVAPOR 2000\nASEC-0639\n88425\nVAPOR 2000\nASEC-0640\n88426\nVAPOR 2000\nASEC-0671\n88427\nVAPOR 2000\nASEC-0672\n88428\nVAPOR 2000\nASEC-0673\n88430\nVAPOR 2000\nASEC-0676\n88431\nVAPOR 2000\nASEC-0677\n88433\nVAPOR 2000\nASEC-0679\n88435\nVAPOR 2000\nASEC-0692\n96452\nVAPOR 2000\nARXC-0017\n96453\nVAPOR 2000\nARWB-1133\n96455\nVAPOR 2000\nARYD-0171\n96457\nVAPOR 2000\nARWD-0028\n96458\nVAPOR 2000\nARWB-1164\n113046\nVAPOR 2000\nASDM-0011\n113047\nVAPOR 2000\nASDM-0012\n113048\nVAPOR 2000\nASDM-0013\n113049\nVAPOR 2000\nASDM-0014\n133705\nVAPOR 2000\nASMA-0196\n158386\nVAPOR 2000\nASPL-0893\n158387\nVAPOR 2000\nASPL-0675\n187329\nVAPOR 2000\nASUE-0263\n187330\nVAPOR 2000\nASUE-0262\n187331\nVAPOR 2000\nASUE-0265\n187332\nVAPOR 2000\nASUE-0261\n187333\nVAPOR 2000\nASUE-0264\n\nThe following is a list of equipment used at 2489 Diplomat Parkway East, Cape Coral, FL 33909 for life-support during surgeries:\n\nEE #\nModel\nSerial\n182453\nFABIUS TIRO\nASTL-0003\n157917\nPERSEUS A500\nASPL-0141\n157915\nPERSEUS A500\nASPM-0060\n157914\nPERSEUS A500\nASPM-0061\n157916\nPERSEUS A500\nASPM-0062\n88437\nD-VAPOR\nASEC-0311\n88439\nD-VAPOR\nASEC-0313\n88442\nD-VAPOR\nASEC-0316\n88453\nD-VAPOR\nASEC-0327\n182458\nD-VAPOR\nASTK-0101\n88412\nVAPOR 2000\nASEC-0128\n88417\nVAPOR 2000\nASEC-0632\n88429\nVAPOR 2000\nASEC-0674\n88432\nVAPOR 2000\nASEC-0678\n88434\nVAPOR 2000\nASEC-0680\n98216\nVAPOR 2000\nASDM-0127\n98217\nVAPOR 2000\nASDM-0126\n98218\nVAPOR 2000\nASDM-0137\n182454\nVAPOR 2000\nASTK-1050\n182457\nVAPOR 2000\nASTL-0215\n\n3.GENERAL REQUIREMENTS: Service\n\nThe contractor shall provide only Draeger trained and certified field service engineers (FSE). The FSE shall be equipped with licensed Draeger maintenance utility software. All FSE maintenance shall be performed in accordance with current Draeger procedures and at Drager recommended frequencies.\n\nAll maintenance will be performed during extended VA business hours, 7:00 AM - 8:00 PM, Monday-Friday, except Federal Holidays, unless otherwise specified. Contractor may work outside normal business hours by arrangement with Contracting Officer s Representative (COR) if such services are provided without additional charge to the government. Any overtime charges must be approved by the Contracting Officer if not included in the contract pricing schedule. COR must notify the Contracting Officer before authorizing overtime work.\n\nThe contractor shall provide emergency repair service 24 hours a day, 7 days a week.\n\nThe VA shall not provide service manuals or service diagnostic software to the contractor. The contractor shall obtain, have on file, and make available to its Field Service Engineers (FSEs) all operational and technical documentation (e.g., operational and service manuals, schematics, and parts lists) which are necessary to meet the performance requirements of the contract. The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the COR upon request. Any charges for parts, manuals, tools, or software required to successfully complete repairs, scheduled maintenance, or certifications shall be included in this contract, and it s agreed upon price.\n\nAll removable media materials (laptop, DVD/CD, USB drive, etc.) need to be scanned on site with approved anti-virus by OI&T or Biomedical staff and approved for use prior to the start of any work.\nA. Parts\n\nThe Contractor shall provide all replacement parts required to complete repairs and maintenance. The contractor shall provide and install consumable items, such as sensors, at no additional cost to VA. All provided parts and software updates must be sourced from Draeger, meeting current manufacturer specifications. Parts removed (replaced) by the contractor become the property of the contractor.\n\nB. Performance Standards\n\nThe COR will assure Contractor performance in accordance with (IAW) the Performance Standard Metrics. In an effort to minimize the performance management burden, the government shall use 100 percent inspection(s) as indicated below:\n\nPERFORMANCE STANDARD METRICS\nRequirement\nQuality Standard\nAction\nSurveillance Method\n1. Contractor provided and utilized procedures and checklists with worksheet originals indicating work performed and actual values obtained provided to the COR at the completion of maintenance.\n100% compliance\nFull payment to Contractor pending completion of this metric.\n\nRegular reviews, inspection and observation; Contractor notified immediately if non-compliance\n\n2. Provided documentation of service performed.\n100% compliance\nFull payment to Contractor pending completion of this metric.\n\nContractor notified immediately if non-compliance\n\n3. Contractor electrical safety inspection at time of PM\n100% compliance\nFull payment to Contractor pending completion of this metric.\n\nContractor notified immediately if non-compliance\n\n4. Equipment functions in conformance with latest Draeger specifications.\n100% compliance\nFull payment to Contractor pending completion of this metric.\n\nRegular reviews, inspection and observation; Contractor notified immediately if non-compliance\n\n4.Special Instructions\n\nA. Contractor Check-in\n\nThe contractor's FSE will report to Biomedical Engineering, 1F122-100-BP or 2B191-CC-OPC, prior to performance of service. All FSEs will be fully credentialed and check in at the facility using the approved credentialing system, currently O.R. TRAX.\n\nB. Documentation\n\nAt the conclusion of each repair or scheduled maintenance visit, the contractor will provide a written service report indicating the date of service, the model, serial number, and location of the equipment serviced, the name of the service representative, the hours worked, and the services performed, and parts replaced. The reports will be delivered electronically to Biomedical Engineering when work is complete.\n\n5.Terms and Conditions: Inspection of Equipment\n\nAny site visit must be coordinated in advance with COR or Biomedical Engineering, 727-398-6661 x15601, there will be no site visits prior to award.\n\n6. CONTRACTOR EXPERIENCE REQUIREMENTS: Each respondent must have an established business, with an office and full time staff to include a \"fully qualified\" field service engineer (FSE) and a \"fully qualified\" FSE who will serve as backup. \"Fully qualified\" is based upon completion of all Draeger factory training for the model being services. The FSE(s) shall be authorized by the contractor to perform the maintenance services. All work shall be performed by \"fully qualified\" competent FSE(s). The contractor shall make available written assurance to the competency of their personnel and a list of credentials of approved FSEs for each make and model the contractor services at the VA. The Contracting Officer Representative (COR) may authenticate the training requirements, request training certificates or credentials from the contractor at any time for any personnel who are servicing or installing any VA equipment. The CO and/or Contracting Officer's Representative (COR) specifically reserves the right to reject any of the contractor's personnel and refuse them permission to work on the VA equipment. If subcontractors are used, they must be approved in advance by the CO; the contractor shall submit any proposed change in subcontractor(s) to the CO for approval/disapproval.\n\n7. PRIVACY TRAINING AND CYBER SECURITY AWARENESS TRAINING: The contractor will be required to comply with physical security guidelines by either checking in with the VA Police each time they come on-site to perform contracted services or by obtaining a VA Contractor ID badge from the VA Police.\nContractor may not have access to any VA sensitive information under this contract.\nContractor must be escorted at all times by VA staff or contractor must complete VA Privacy and Information Security Awareness and Rules of Behavior training.\n\n8.Training Requirements:\n1.Services must ONLY be performed by Draeger trained technicians, who have evidence of current factory training on the specific device being serviced (Draeger Ventilation, Anesthesia, Monitor, or Neonatal Device)\n2.Must provide evidence of equipment standards and traceability and final device performance testing that follows and complies with all manufacturer procedural requirements.\n3.Must guarantee that safety inspections performed will comply with all applicable federal, state and regulatory requirements, manufacturer standards, and meet FDA alerts and recall requirements.\n4.Each technician must be certified on the applicable Draeger Ventilation Device prior to performing any service and/or maintenance on Draeger manufactured equipment.\n5.Must provide evidence of recent attendance and successful completion of the Draeger Factory Training Seminars for each product serviced.\n6.Must maintain continuous access to the Draeger Service Connect system, which provides all of the relevant and up-to-date Technical Documentation and information for each of the Draeger products serviced.\n7.Must guarantee execution of all Manufacturer Service Recommendations during each service incident, including the use of ONLY manufacturer planned maintenance and repair parts. (Note: Failure to utilize original manufacturer parts may result in the improper operation of the equipment.)\n8.Must possess the legal rights to propriety equipment diagnostic software. (Note: Failure to utilize the Propriety Software may result in the inability to identify equipment operating parameters and to accurately calibrate the equipment.)\n9.The service technician must have completed training for each specific device by a Draeger Authorized Trainer prior to performing service on said device and provide proof of such prior to contract award.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24826Q0032","place_of_performance":{"zip":"33744","city":{"code":"4200","name":"Bay Pines"},"state":{"code":"FL","name":"Florida"},"street":"C.W. Bill Young Veterans Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10000 Bay Pines Blvd."},"product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2025-11-05","posted_at":"2025-11-05T17:09:45.687Z","created_at":"2025-11-05T17:09:43.496Z","modified_at":"2025-11-30T05:04:30.995Z","response_deadline":{"raw":"2025-11-20T14:00:00-05:00","utc":"2025-11-20T19:00:00Z","date":"2025-11-20","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/367befefc83149d8a50dfdbb8e171f1d/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY26: Draeger Anesthesia System Maintenance","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-30","archive_type":"auto_custom"},"history":[{"index":9,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance Sources Sought Only","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-30T18:15:36.800Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4","solicitation_number":"36C24826Q0032","related_opportunity_id":"35cf348cb4a743e680fe0477d5ea1c56"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"367befefc83149d8a50dfdbb8e171f1d","lineage_id":"80c06e8aca7443f3927f6a1c1d9815b4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-23T04:54:09.235399120Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"7d488c97576f83bfdef3c056c27126f02395dcea15401bcfbfc55e7409f11df0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-23T04:54:09.235399120Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"This solicitation will be for a firm fixed price base plus two option years contract award. This solicitation will be posted on or before the 13th of November.  \nGeneral: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines.  The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.  \n\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below.  The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.  \n\nPlease, when providing your quote for this requirement furnish your current copy of the Draeger Technician Certificate Authorized for your tech person that is Authorized to work on the equipment that will be listed in the SOW on the RFQ.","text":"This solicitation will be for a firm fixed price base plus two option years contract award. This solicitation will be posted on or before the 13th of November.\nGeneral: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines. The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.\n\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below. The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.\n\nPlease, when providing your quote for this requirement furnish your current copy of the Draeger Technician Certificate Authorized for your tech person that is Authorized to work on the equipment that will be listed in the SOW on the RFQ.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24826Q0032","place_of_performance":{"zip":"33744","city":{"name":"Bay Pines"},"state":{"name":"FL."},"street":"C.W. Bill Young Veterans Medical Center","street2":"10000 Bay Pines Blvd."},"product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2025-11-07","posted_at":"2025-11-07T20:09:15.566Z","created_at":"2025-11-07T20:09:11.280Z","modified_at":"2025-11-30T05:04:30.995Z","response_deadline":{"raw":"2025-11-20T14:00:00-05:00","utc":"2025-11-20T19:00:00Z","date":"2025-11-20","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/69cc3d029f5b41209809881324d56f29/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY26: Draeger Anesthesia System Maintenance","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-30","archive_type":"auto_custom"},"history":[{"index":9,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-25T18:02:40.252Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"df1b8571a20a4e878c63049b2e716554","solicitation_number":"36C24826Q0032","related_opportunity_id":"69cc3d029f5b41209809881324d56f29"},{"index":7,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"},{"index":5,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-05T17:09:45.687Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"367befefc83149d8a50dfdbb8e171f1d","solicitation_number":"36C24826Q0032","related_opportunity_id":"80c06e8aca7443f3927f6a1c1d9815b4"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"69cc3d029f5b41209809881324d56f29","lineage_id":"367befefc83149d8a50dfdbb8e171f1d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-23T02:48:27.281061271Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"b356340e8382449114e8d8d5df48a75205d3dc1d51d90b35b347fa720864c29d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-23T02:48:27.281061271Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"General: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines.  The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.  \n\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below.  The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","text":"General: The Department of Veterans Affairs, Bay Pines VA Healthcare System is soliciting a requirement for a comprehensive Draeger anesthesia devices maintenance and certification agreement for twenty-four (24) anesthesia machines. The Anesthesia Machine Preventative Maintenance (PM) and Certification agreement shall provide corrective and planned maintenance on six (6) Draeger Fabius TIRO anesthesia machines, eighteen (18) Draeger Persius A500 anesthesia machines, and sixty-nine (69) vaporizers.\n\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below. The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24826Q0032","product_service_code":"J065"},{"award":{"date":"2025-11-25","amount":"82583.65","number":"36C24826P0193","awardee":{"raw":"DRAEGER INC TELFORD 18969","uei":"M835NJ4FS8T9","cage":"6L622","name":"DRAEGER INC","location":{"zip":"18969","city":{"name":"TELFORD"},"state":{"name":"PA"},"country":{"name":"PA"}}}},"dates":{"posted":"2025-11-25","posted_at":"2025-11-25T18:02:40.252Z","award_date":"2025-11-25","created_at":"2025-11-25T18:02:37.954Z","modified_at":"2025-12-11T04:55:46.645Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/df1b8571a20a4e878c63049b2e716554/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY26: Draeger Anesthesia System Maintenance","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-12-10","archive_type":"auto_custom"},"history":[{"index":6,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-25T18:02:40.252Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"df1b8571a20a4e878c63049b2e716554","solicitation_number":"36C24826Q0032","related_opportunity_id":"69cc3d029f5b41209809881324d56f29"},{"index":4,"title":"J065--FY26: Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T20:09:15.566Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"69cc3d029f5b41209809881324d56f29","solicitation_number":"36C24826Q0032","related_opportunity_id":"367befefc83149d8a50dfdbb8e171f1d"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"df1b8571a20a4e878c63049b2e716554","lineage_id":"69cc3d029f5b41209809881324d56f29","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-21T02:46:52.593090680Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"1c1a57a19992f40e9b90df8fb5937b1582850a0826dc7afc5a14a01e7e6a4072","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-21T02:46:52.593090680Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24826Q0032","product_service_code":"J065"},{"award":{"date":"2026-10-21","amount":"0","number":"36C24826P0193P00002","awardee":{"raw":"DRAEGER INC TELFORD 18969","uei":"M835NJ4FS8T9","cage":"6L622","name":"DRAEGER INC","location":{"zip":"18969","city":{"name":"TELFORD"},"state":{"name":"PA"},"country":{"name":"PA"}}}},"dates":{"posted":"2026-10-21","posted_at":"2026-10-21T14:10:55.179Z","award_date":"2026-10-21","created_at":"2026-10-21T14:10:52.949Z","modified_at":"2026-10-21T14:10:55.179Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/d0b5fcee9dd1455ab38819f897896eac/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--FY27 Option Year 1 Mod Draeger Anesthesia System Maintenance","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-05","archive_type":"auto_custom"},"history":[{"index":1,"title":"J065--FY27 Option Year 1 Mod Draeger Anesthesia System Maintenance","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-21T14:10:55.179Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"d0b5fcee9dd1455ab38819f897896eac","solicitation_number":"36C24826Q0032"}],"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contracting Officer"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"d0b5fcee9dd1455ab38819f897896eac","lineage_id":"d0b5fcee9dd1455ab38819f897896eac","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-23T00:24:34.838623975Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"58dd0847711150ff9c95055bfa6976ad-26\"","fetched_at":"2026-11-05T04:33:40.972004995Z","row_sha256":"45cfd153c25c0a409d89a3ab4ecec22837294582ce274d0eb81a595141cfcfe1","last_modified":"2026-11-05T04:30:52Z"},"updated_at":"2026-11-05T04:33:40.972004995Z","first_seen_at":"2026-10-22T04:05:36.750841648Z"},"description":{"html":"Exercise of option year one\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below.  The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","text":"Exercise of option year one\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below. The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24826Q0032","product_service_code":"J065"}],"due_at":"2025-11-20T19:00:00Z","due_date":"2025-11-20","closes_at":"2025-11-20T19:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"M835NJ4FS8T9","amount":"0","linked_awards":6,"cancelled":false,"archived":true,"updated_at":"2026-11-06T06:19:49.421993Z","principal_notice_id":"d0b5fcee9dd1455ab38819f897896eac","description":{"text":"Exercise of option year one\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below. The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","html":"Exercise of option year one\nSCOPE: The contractor shall furnish all labor, transportation, and parts needed to provide and meet VA acceptability standards for all repair, preventive, and inspection maintenance activities to ensure optimized uptime of DrÃ¤ger anesthesia equipment listed below.  The contractor shall maintain the equipment and assure its proper function to reduce equipment downtime.","origin":"detail"},"contacts":[{"name":"Michael A Shook","role":"primary","email":"Michael.Shook@va.gov","phone":"813-972-2000 Ext 2819","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"naics_codes":["811210"],"award":{"date":"2026-10-21","amount":"0","number":"36C24826P0193P00002","awardee":{"raw":"DRAEGER INC TELFORD 18969","uei":"M835NJ4FS8T9","cage":"6L622","name":"DRAEGER INC","location":{"zip":"18969","city":{"name":"TELFORD"},"state":{"name":"PA"},"country":{"name":"PA"}}}},"attachments":[{"resource_id":"112a72e406de44c3a7bc91cd9e16d0c9","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-11-05T17:09:45.687Z","export_controlled":false,"sha256":null,"url":"http://www.va.gov","mirrored":false},{"resource_id":"20463c7d37b74558a085a3fc92a8424f","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-10-29T15:56:06.777Z","export_controlled":false,"sha256":null,"url":"http://www.va.gov","mirrored":false},{"resource_id":"7800f616b67742c89611c8a412921611","name":"36C24826P0193 P00002_1.docx","kind":"file","mime_type":".docx","size_bytes":14449,"posted_at":"2026-10-21T14:10:55.179Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7800f616b67742c89611c8a412921611/download","mirrored":false},{"resource_id":"8194d92c82cc41b3b5a8daf122df6fb8","name":"36C24826P0193_1.docx","kind":"file","mime_type":".docx","size_bytes":13628,"posted_at":"2025-11-25T18:02:40.252Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8194d92c82cc41b3b5a8daf122df6fb8/download","mirrored":false},{"resource_id":"a6e12cde590f452cabfb45beb2e0bb2f","name":"36C24826Q0032_1.docx","kind":"file","mime_type":".docx","size_bytes":25193,"posted_at":"2025-10-30T18:15:36.800Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a6e12cde590f452cabfb45beb2e0bb2f/download","mirrored":false},{"resource_id":"1d13114037284048bededbfb2bc2a9bc","name":"36C24826Q0032_3.docx","kind":"file","mime_type":".docx","size_bytes":361671,"posted_at":"2025-11-07T20:09:15.566Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1d13114037284048bededbfb2bc2a9bc/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24826P0193_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24826P0193_3600_-NONE-_-NONE-/","piid":"36C24826P0193","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"M835NJ4FS8T9","recipient_name":"DRAEGER INC","recipient_uei":"M835NJ4FS8T9","recipient_cage":"6L622","recipient_city":"TELFORD","recipient_state":"PA","sub_name":"Department of Veterans Affairs","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","office_key":"o-36C248","first_action_date":"2025-11-25","last_action_date":"2026-10-21","actions":3,"obligated":"165167.30","current_total_value":"165167.30","potential_total_value":"247750.95","naics":"811210","psc":"J065","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":3,"description":"DRAEGER ANESTHESIA SYSTEM MAINTENANCE","method":"piid","confidence":"high","evidence":["award number 36C24826P0193 equals the contract number","same awarding office 36C248"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24827Q0051","latest_notice_id":"d56f5324e7874602ba56b5268afbad47","title":"J065--Neptune Rover Medical Surgical Maintenance Base plus Four (4) Option Years","solicitation_number":"36C24827Q0051","notice_type":"o","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J065","set_aside":null,"state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T07:01:08.699328Z"},{"key":"36C24827Q0155","latest_notice_id":"831665dca3fc431482f486284606c5a5","title":"J026--Pneumatic Tube System Preventive Maintenance","solicitation_number":"36C24827Q0155","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238290","psc":"J026","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24827Q0143","latest_notice_id":"06bab5721d954ba4a41ceb4b0ae7266c","title":"H199--FY27 Cathodic Protection Inspection and Testing","solicitation_number":"36C24827Q0143","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"541380","psc":"H199","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"},{"key":"36C24827Q0152","latest_notice_id":"d164c447673a46eab4845cf7111b79ac","title":"6515--Fresenius 5008X Machines","solicitation_number":"36C24827Q0152","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"6515","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"36C24827Q0051","latest_notice_id":"d56f5324e7874602ba56b5268afbad47","title":"J065--Neptune Rover Medical Surgical Maintenance Base plus Four (4) Option Years","solicitation_number":"36C24827Q0051","notice_type":"o","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J065","set_aside":null,"state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T07:01:08.699328Z"},{"key":"FA481427Q0001","latest_notice_id":"1f85999146e1475c8b8a4b43ffcbf704","title":"Preventative Shredder Maintenance","solicitation_number":"FA481427Q0001","notice_type":"o","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":4,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4814","office_name":"FA4814 6 CONS PK","naics":"811210","psc":"J074","set_aside":"SBA","state":"FL","county":"12057","county_name":"Hillsborough County","city":"1271000","city_name":"Tampa","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24827Q0159","latest_notice_id":"aa5ec5c8d4d34aadb0dc674a48c67b31","title":"J041--FY27 TempTrak Monitoring","solicitation_number":"36C24827Q0159","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J041","set_aside":"SDVOSBC","state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":61,"indexable":false}