{"canonical":"https://sealedbidder.com/opportunities/36c24825q0885","key":"36C24825Q0885","url":"https://sealedbidder.com/opportunities/36c24825q0885","title":"J061--FY25: Lake Nona Medium Voltage Repair","solicitation_number":"36C24825Q0885","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-16T15:00:00Z","first_posted":"2025-06-13","last_posted":"2025-06-13","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238210","psc":"J061","set_aside":null,"place_state":"FL","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"0 AM (LOCAL TIME) LOCATION: ORLANDO VA MEDICAL CENTER AT LAKE NONA, 13800 VETERANS WAY, ORLANDO, FL 32827","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"e99b7a72f1b4431399cdd8438645d194","title":"J061--FY25: Lake Nona Medium Voltage Repair","solicitation_number":"36C24825Q0885","notice_type":"s","base_type":"s","posted":"2025-06-13","posted_at":"2025-06-13T19:18:51.262Z","due_at":"2025-06-16T15:00:00Z","due_date":"2025-06-16","cancelled":false,"archived":true,"archive_date":"2025-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e99b7a72f1b4431399cdd8438645d194/view","enriched":true,"history":[{"index":3,"title":"J061--FY25: Lake Nona Medium Voltage Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T19:18:51.262Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"e99b7a72f1b4431399cdd8438645d194","solicitation_number":"36C24825Q0885"}]}],"latest_notice_id":"e99b7a72f1b4431399cdd8438645d194","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-13","posted_at":"2025-06-13T19:18:51.262Z","created_at":"2025-06-13T19:18:48.820Z","modified_at":"2025-08-15T04:02:19.987Z","response_deadline":{"raw":"2025-06-16T11:00:00-04:00","utc":"2025-06-16T15:00:00Z","date":"2025-06-16","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e99b7a72f1b4431399cdd8438645d194/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--FY25: Lake Nona Medium Voltage Repair","agency":{"office":{"code":"36C248","name":"248-NETWORK CONTRACT OFFICE 8 (36C248)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"organization_id":"100167097","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-15","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--FY25: Lake Nona Medium Voltage Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T19:18:51.262Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"e99b7a72f1b4431399cdd8438645d194","solicitation_number":"36C24825Q0885"}],"contacts":[{"name":"Rohan McKenzie","role":"primary","email":"Rohan.Mckenzie@va.gov","phone":"407-631-8720","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"e99b7a72f1b4431399cdd8438645d194","lineage_id":"e99b7a72f1b4431399cdd8438645d194","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T14:41:38.873537964Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"bc50840f51943e98b69d375bc541e208bcba2767c164adbaf1f1855e8e820396","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T14:41:38.873537964Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The Department of Veteran Affairs, Network Contracting Office 08 invites interested Contractors to attend a site visit for the purpose of assessing the issues identified in the government-generated Trouble Call report. This site visit will assist prospective offers in  evaluating the work environment and technical requirements in preparation for submitting a quote under the upcoming Request for Quote (RFQ).\nInstructions:\nInterested parties must pre-register attendees (no more than two) by providing names to Robert.edwards2@va.gov and rohan.mckenzie@va.gov no later than June 16, 2025, 11:00 AM.  Please arrive on time and bring proper identification to gain access to the facility. \nSite Visit Details:\nDate: June 17, 2025\nTime: 10:00 AM (local time)\nLocation: Orlando VA Medical Center at Lake Nona, 13800 Veterans Way, Orlando, FL 32827\nMeeting Point: Inside the lobby near the piano\nPurpose: Visual inspection and discussion of the issue described in Trouble Call Report\nFollow-up: Contractor questions will be address on-site and incorporated into the forthcoming RFQ as appropriate.\nBackground:\nEmergency (generator) power circuit(s) to the Lake Nona clinic are faulted and/or unreliable.\nThe medium voltage circuit DAG-3 is the emergency (generator) circuit powering the Clinic substation SS-CG2; and is the alternate power source for Clinic substation SS-CG1. It was Hi-Pot tested and the report indicated a catastrophic failure on B-phase, requiring both substations to be placed on the alternate circuit (DAG-15) with no redundancy. A visual inspection of manholes EA1-1 and EA1-2 in the duct bank series noted splices in them that show signs corrosion and degradation. Troubleshooting, testing was performed on the circuit and damage to the B-phase conductor insulation is suspected to be localized the within the ductwork itself requiring emergent replacement.\nThe medium voltage circuit DAG-15 is the emergency (generator) circuit powering the Clinic substation SS-CG1 and is the alternate power source for Clinic substation SS-CG2. It was Hi-Pot tested and the report indicated signs of leakage, likely from several splices/phases in the duct bank series manholes. A visual assessment was performed in conjunction with the Hi-Pot test and noted signs of swelling on several splices. Circuit DAG15 is the sole operable emergency (generator) circuit to the Clinic substations SS-CG1/2 (in its current switched state) and in urgent need of replacement and/or repair.\nThe Normal power circuit to the Lake Nona Domiciliary is unreliable. The medium voltage circuit DAN-2 is the sole normal power circuit powering the Domiciliary substation SS-DG1. It was quickly identified to have sustained a catastrophic splice failure on only C-phase on 12Nov24 in manhole NA2-5. Only C- phase splice was repaired, and the circuit was put back in service in >24hrs. During the visual assessment splices were noted in manholes NA2-5, NA2-6, NA2-7, and NA2-8 with various signs of corrosion and swelling indicative of impending failure. Circuit DAN-2 requires urgent replacement.\nDBN-7 Hospital (Normal Power) circuit - A visual assessment confirmed smoke and electrical burning signs from manhole NB2-3 near the golf cart yard of the warehouse.Â  Suspected leaking splice damage.Â IMG_1005 1.3gp.\nAttachments:\nATTACHMENT A - Trouble Call Report of the Hi-Pot Cable test DAG-3 \nATTACHMENT B - Trouble Call Report of the Hi-Pot Cable test DAG-15 \nNote: This notice is for informational and planning purposes only. It does not constitute a solicitation or guarantee of future contract award.","text":"The Department of Veteran Affairs, Network Contracting Office 08 invites interested Contractors to attend a site visit for the purpose of assessing the issues identified in the government-generated Trouble Call report. This site visit will assist prospective offers in evaluating the work environment and technical requirements in preparation for submitting a quote under the upcoming Request for Quote (RFQ).\nInstructions:\nInterested parties must pre-register attendees (no more than two) by providing names to Robert.edwards2@va.gov and rohan.mckenzie@va.gov no later than June 16, 2025, 11:00 AM. Please arrive on time and bring proper identification to gain access to the facility.\nSite Visit Details:\nDate: June 17, 2025\nTime: 10:00 AM (local time)\nLocation: Orlando VA Medical Center at Lake Nona, 13800 Veterans Way, Orlando, FL 32827\nMeeting Point: Inside the lobby near the piano\nPurpose: Visual inspection and discussion of the issue described in Trouble Call Report\nFollow-up: Contractor questions will be address on-site and incorporated into the forthcoming RFQ as appropriate.\nBackground:\nEmergency (generator) power circuit(s) to the Lake Nona clinic are faulted and/or unreliable.\nThe medium voltage circuit DAG-3 is the emergency (generator) circuit powering the Clinic substation SS-CG2; and is the alternate power source for Clinic substation SS-CG1. It was Hi-Pot tested and the report indicated a catastrophic failure on B-phase, requiring both substations to be placed on the alternate circuit (DAG-15) with no redundancy. A visual inspection of manholes EA1-1 and EA1-2 in the duct bank series noted splices in them that show signs corrosion and degradation. Troubleshooting, testing was performed on the circuit and damage to the B-phase conductor insulation is suspected to be localized the within the ductwork itself requiring emergent replacement.\nThe medium voltage circuit DAG-15 is the emergency (generator) circuit powering the Clinic substation SS-CG1 and is the alternate power source for Clinic substation SS-CG2. It was Hi-Pot tested and the report indicated signs of leakage, likely from several splices/phases in the duct bank series manholes. A visual assessment was performed in conjunction with the Hi-Pot test and noted signs of swelling on several splices. Circuit DAG15 is the sole operable emergency (generator) circuit to the Clinic substations SS-CG1/2 (in its current switched state) and in urgent need of replacement and/or repair.\nThe Normal power circuit to the Lake Nona Domiciliary is unreliable. The medium voltage circuit DAN-2 is the sole normal power circuit powering the Domiciliary substation SS-DG1. It was quickly identified to have sustained a catastrophic splice failure on only C-phase on 12Nov24 in manhole NA2-5. Only C- phase splice was repaired, and the circuit was put back in service in >24hrs. During the visual assessment splices were noted in manholes NA2-5, NA2-6, NA2-7, and NA2-8 with various signs of corrosion and swelling indicative of impending failure. Circuit DAN-2 requires urgent replacement.\nDBN-7 Hospital (Normal Power) circuit - A visual assessment confirmed smoke and electrical burning signs from manhole NB2-3 near the golf cart yard of the warehouse.Â Suspected leaking splice damage.Â IMG_1005 1.3gp.\nAttachments:\nATTACHMENT A - Trouble Call Report of the Hi-Pot Cable test DAG-3\nATTACHMENT B - Trouble Call Report of the Hi-Pot Cable test DAG-15\nNote: This notice is for informational and planning purposes only. It does not constitute a solicitation or guarantee of future contract award.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24825Q0885","product_service_code":"J061"}],"due_at":"2025-06-16T15:00:00Z","due_date":"2025-06-16","closes_at":"2025-06-16T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","state":"FL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"0 AM (LOCAL TIME) LOCATION: ORLANDO VA MEDICAL CENTER AT LAKE NONA, 13800 VETERANS WAY, ORLANDO, FL 32827","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-12T14:55:29.624557Z","principal_notice_id":"e99b7a72f1b4431399cdd8438645d194","description":{"text":"The Department of Veteran Affairs, Network Contracting Office 08 invites interested Contractors to attend a site visit for the purpose of assessing the issues identified in the government-generated Trouble Call report. This site visit will assist prospective offers in evaluating the work environment and technical requirements in preparation for submitting a quote under the upcoming Request for Quote (RFQ).\nInstructions:\nInterested parties must pre-register attendees (no more than two) by providing names to Robert.edwards2@va.gov and rohan.mckenzie@va.gov no later than June 16, 2025, 11:00 AM. Please arrive on time and bring proper identification to gain access to the facility.\nSite Visit Details:\nDate: June 17, 2025\nTime: 10:00 AM (local time)\nLocation: Orlando VA Medical Center at Lake Nona, 13800 Veterans Way, Orlando, FL 32827\nMeeting Point: Inside the lobby near the piano\nPurpose: Visual inspection and discussion of the issue described in Trouble Call Report\nFollow-up: Contractor questions will be address on-site and incorporated into the forthcoming RFQ as appropriate.\nBackground:\nEmergency (generator) power circuit(s) to the Lake Nona clinic are faulted and/or unreliable.\nThe medium voltage circuit DAG-3 is the emergency (generator) circuit powering the Clinic substation SS-CG2; and is the alternate power source for Clinic substation SS-CG1. It was Hi-Pot tested and the report indicated a catastrophic failure on B-phase, requiring both substations to be placed on the alternate circuit (DAG-15) with no redundancy. A visual inspection of manholes EA1-1 and EA1-2 in the duct bank series noted splices in them that show signs corrosion and degradation. Troubleshooting, testing was performed on the circuit and damage to the B-phase conductor insulation is suspected to be localized the within the ductwork itself requiring emergent replacement.\nThe medium voltage circuit DAG-15 is the emergency (generator) circuit powering the Clinic substation SS-CG1 and is the alternate power source for Clinic substation SS-CG2. It was Hi-Pot tested and the report indicated signs of leakage, likely from several splices/phases in the duct bank series manholes. A visual assessment was performed in conjunction with the Hi-Pot test and noted signs of swelling on several splices. Circuit DAG15 is the sole operable emergency (generator) circuit to the Clinic substations SS-CG1/2 (in its current switched state) and in urgent need of replacement and/or repair.\nThe Normal power circuit to the Lake Nona Domiciliary is unreliable. The medium voltage circuit DAN-2 is the sole normal power circuit powering the Domiciliary substation SS-DG1. It was quickly identified to have sustained a catastrophic splice failure on only C-phase on 12Nov24 in manhole NA2-5. Only C- phase splice was repaired, and the circuit was put back in service in >24hrs. During the visual assessment splices were noted in manholes NA2-5, NA2-6, NA2-7, and NA2-8 with various signs of corrosion and swelling indicative of impending failure. Circuit DAN-2 requires urgent replacement.\nDBN-7 Hospital (Normal Power) circuit - A visual assessment confirmed smoke and electrical burning signs from manhole NB2-3 near the golf cart yard of the warehouse.Â Suspected leaking splice damage.Â IMG_1005 1.3gp.\nAttachments:\nATTACHMENT A - Trouble Call Report of the Hi-Pot Cable test DAG-3\nATTACHMENT B - Trouble Call Report of the Hi-Pot Cable test DAG-15\nNote: This notice is for informational and planning purposes only. It does not constitute a solicitation or guarantee of future contract award.","html":"The Department of Veteran Affairs, Network Contracting Office 08 invites interested Contractors to attend a site visit for the purpose of assessing the issues identified in the government-generated Trouble Call report. This site visit will assist prospective offers in  evaluating the work environment and technical requirements in preparation for submitting a quote under the upcoming Request for Quote (RFQ).\nInstructions:\nInterested parties must pre-register attendees (no more than two) by providing names to Robert.edwards2@va.gov and rohan.mckenzie@va.gov no later than June 16, 2025, 11:00 AM.  Please arrive on time and bring proper identification to gain access to the facility. \nSite Visit Details:\nDate: June 17, 2025\nTime: 10:00 AM (local time)\nLocation: Orlando VA Medical Center at Lake Nona, 13800 Veterans Way, Orlando, FL 32827\nMeeting Point: Inside the lobby near the piano\nPurpose: Visual inspection and discussion of the issue described in Trouble Call Report\nFollow-up: Contractor questions will be address on-site and incorporated into the forthcoming RFQ as appropriate.\nBackground:\nEmergency (generator) power circuit(s) to the Lake Nona clinic are faulted and/or unreliable.\nThe medium voltage circuit DAG-3 is the emergency (generator) circuit powering the Clinic substation SS-CG2; and is the alternate power source for Clinic substation SS-CG1. It was Hi-Pot tested and the report indicated a catastrophic failure on B-phase, requiring both substations to be placed on the alternate circuit (DAG-15) with no redundancy. A visual inspection of manholes EA1-1 and EA1-2 in the duct bank series noted splices in them that show signs corrosion and degradation. Troubleshooting, testing was performed on the circuit and damage to the B-phase conductor insulation is suspected to be localized the within the ductwork itself requiring emergent replacement.\nThe medium voltage circuit DAG-15 is the emergency (generator) circuit powering the Clinic substation SS-CG1 and is the alternate power source for Clinic substation SS-CG2. It was Hi-Pot tested and the report indicated signs of leakage, likely from several splices/phases in the duct bank series manholes. A visual assessment was performed in conjunction with the Hi-Pot test and noted signs of swelling on several splices. Circuit DAG15 is the sole operable emergency (generator) circuit to the Clinic substations SS-CG1/2 (in its current switched state) and in urgent need of replacement and/or repair.\nThe Normal power circuit to the Lake Nona Domiciliary is unreliable. The medium voltage circuit DAN-2 is the sole normal power circuit powering the Domiciliary substation SS-DG1. It was quickly identified to have sustained a catastrophic splice failure on only C-phase on 12Nov24 in manhole NA2-5. Only C- phase splice was repaired, and the circuit was put back in service in >24hrs. During the visual assessment splices were noted in manholes NA2-5, NA2-6, NA2-7, and NA2-8 with various signs of corrosion and swelling indicative of impending failure. Circuit DAN-2 requires urgent replacement.\nDBN-7 Hospital (Normal Power) circuit - A visual assessment confirmed smoke and electrical burning signs from manhole NB2-3 near the golf cart yard of the warehouse.Â  Suspected leaking splice damage.Â IMG_1005 1.3gp.\nAttachments:\nATTACHMENT A - Trouble Call Report of the Hi-Pot Cable test DAG-3 \nATTACHMENT B - Trouble Call Report of the Hi-Pot Cable test DAG-15 \nNote: This notice is for informational and planning purposes only. It does not constitute a solicitation or guarantee of future contract award.","origin":"detail"},"contacts":[{"name":"Rohan McKenzie","role":"primary","email":"Rohan.Mckenzie@va.gov","phone":"407-631-8720","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"33637","city":"TAMPA","state":"FL","country":"USA"},"naics_codes":["238210"],"award":{"awardee":{}},"attachments":[{"resource_id":"c57db90b674c41a4ab3627e638968a80","name":"36C24825Q0885.docx","kind":"file","mime_type":".docx","size_bytes":17827,"posted_at":"2025-06-13T19:18:51.262Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c57db90b674c41a4ab3627e638968a80/download","mirrored":false},{"resource_id":"3d132d4f5e1348d39e0fa94ae02cdc76","name":"ATTACHMENT A HI-POT TEST SHEET DAG-3.pdf","kind":"file","mime_type":".pdf","size_bytes":106854,"posted_at":"2025-06-13T19:18:51.262Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3d132d4f5e1348d39e0fa94ae02cdc76/download","mirrored":false},{"resource_id":"5a67253090184bdd83a381aaea6272d5","name":"ATTACHMENT B HI-POT TEST SHEET DAG-15.pdf","kind":"file","mime_type":".pdf","size_bytes":105907,"posted_at":"2025-06-13T19:18:51.262Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5a67253090184bdd83a381aaea6272d5/download","mirrored":false}],"awards":[],"related":[{"key":"36C24827Q0051","latest_notice_id":"d56f5324e7874602ba56b5268afbad47","title":"J065--Neptune Rover Medical Surgical Maintenance Base plus Four (4) Option Years","solicitation_number":"36C24827Q0051","notice_type":"o","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"811210","psc":"J065","set_aside":null,"state":"FL","county":"12103","county_name":"Pinellas County","city":"1204200","city_name":"Bay Pines","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T07:01:08.699328Z"},{"key":"36C24827Q0155","latest_notice_id":"831665dca3fc431482f486284606c5a5","title":"J026--Pneumatic Tube System Preventive Maintenance","solicitation_number":"36C24827Q0155","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"238290","psc":"J026","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24827Q0143","latest_notice_id":"06bab5721d954ba4a41ceb4b0ae7266c","title":"H199--FY27 Cathodic Protection Inspection and Testing","solicitation_number":"36C24827Q0143","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"541380","psc":"H199","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24827Q0085","latest_notice_id":"deec231df02144f98098a3d7c681c25c","title":"W065--FY27 Mobile CT Scanner Lease","solicitation_number":"36C24827Q0085","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"W065","set_aside":null,"state":"FL","county":"12095","county_name":"Orange County","city":"1253000","city_name":"Orlando","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-15T00:31:52.781180Z"},{"key":"36C24827Q0152","latest_notice_id":"d164c447673a46eab4845cf7111b79ac","title":"6515--Fresenius 5008X Machines","solicitation_number":"36C24827Q0152","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C248","office_name":"248-NETWORK CONTRACT OFFICE 8 (36C248)","naics":"334510","psc":"6515","set_aside":null,"state":"PR","county":"72127","county_name":"San Juan Municipio","city":"7276770","city_name":"San Juan","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"36C77627Q0073","latest_notice_id":"19b03a46d29b4624b4914f080833b135","title":"Y1DA--FY27 NRM - EHRM Base 573-27-702-DB EHRM Generator Upgrades Design-Build - Gainesville VAMC","solicitation_number":"36C77627Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-07T19:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C776","office_name":"PCAC (36C776)","naics":"238210","psc":"Y1DA","set_aside":null,"state":"FL","county":"12001","county_name":"Alachua County","city":"1225175","city_name":"Gainesville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Gainesville VA Medical Center","site_key":"gainesville-va-medical-center-fl","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"1232SA27Q0021","latest_notice_id":"8c35373e3e5c4e3bb88b3fb51c3ea2c1","title":"Electrical Installation of 5-Station Cubicle and One Single Hotel Desk Arrangement","solicitation_number":"1232SA27Q0021","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"238210","psc":"N059","set_aside":"SBA","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"1240LU26Q0132","latest_notice_id":"7772e7cbaf1a46409b142ded751c8ec8","title":"USDA Forest Service - Hebgen Lake District Office Network Cabling and IT Room Improvements","solicitation_number":"1240LU26Q0132","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-11-05","notices":4,"due_at":"2026-11-26T00:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LU","office_name":"USDA-FS, CSA INTERMOUNTAIN 9","naics":"238210","psc":"N061","set_aside":"SBA","state":"MT","county":"30031","county_name":"Gallatin County","city":"3079525","city_name":"West Yellowstone","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open_total":41,"indexable":false}