Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,679 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Combined synopsis and solicitation, total small business set-aside

FY25: Respirator Fit and Testing Training Services at VACHS

36C24825Q0168

Department of Veterans Affairs, 248-Network Contract Office 8. Other Scientific and Technical Consulting Services.

Awarded

Enviro Safety Compliance Alternative Inc.

$97,934.00 obligated so far on USAspending

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one was awarded in 2025

8 like it are open now in other scientific and technical consulting services

All 8 open in other scientific and technical consulting services

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
Who may compete
Total small business set-aside. Only small businesses may compete. Small, under NAICS 541690 (other scientific and technical consulting services), means no more than $19 million in average annual receipts, counted with affiliates. Open Small business opportunities
Time to respond
Bidders had 11 days from the day the solicitation was posted, January 3, 2025, to the deadline.
How it ended
Awarded to Enviro Safety Compliance Alternative Inc. on February 12, 2025, 29 days after offers were due. The contracting office reported 2 offers (competed under simplified acquisition procedures).

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

The purpose of this amendment is to provide responses to questions made during the question-and-answer period. As of January 07, 2025, question and answer period has ended as of 12:00 PM EST. Questions will no longer be entertained. Please submit quotes to Contract Specialist Eunice Bones at eunice.bones@va.gov and Contracting Officer Aurea Gonzalez at aurea.gonzalez@va.gov by January 14, 2025, at 13:00 PM EST. Quote/Offer due date remains unchanged. All other areas of solicitation remain unchanged.

RESPONSE TO VENDORS QUESTIONS QUESTION: Refers to Performance Work Statement Q1. In section 2.1 it states: Contractor shall provide services to conduct the quantitative and qualitative fit testing of any of the following types of respirators in compliance with all applicable regulations including but not limited to 29 CFR 1910.134, OSHA Respirator Standard: disposable particulate respirators (i.e. N95 filtering face piece) and elastomeric half-face and full-face respirators.

All respirators to conduct the fit testing and fit testing kits will be supplied by the VACHS. A. Since most respirators utilized in healthcare setting are N95 masks, does the VACHS desire to have quantitative fit testing completed and qualitative fit testing completed for all respirators? If so, what are the ratios between the two types of testing methods?

ANSWER (Q1-A): Fit testing is to be performed IAW approved OSHA accepted protocols as detailed in 1910.134. For the most part, over 95% of the fit testing completed at the facility are qualitative. B. All fit testing kits will be supplied by the VACHS; will this include the quantitative fit testing equipment/machines (i..e., PortaCount, AccuFIT, etc.)?

ANSWER (Q1-B): Qualitative fit testing kits will be supplied by VA Caribbean Healthcare System (VACHS). Quantitative fit testing calibrated equipment will be available upon request and will be supplied by VACHS.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
CA7DU9RD7J11
CAGE
4WEA9
Vendor location
San Juan, PR
Contract
36C24825P0597, purchase order
Obligated
$97,934.00, potential $244,835
Actions
3 between February 12, 2025 and June 9, 2026
Competition
Competed Under SAP, 2 offers received
Set-aside reported
Small Business Set Aside - Total
Described as
Respirator Fit and Testing Training Services
Match
solicitation number 36C24825Q0168 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. January 3, 2025

    Combined synopsis and solicitation

    Due January 14, 2025 at 1:00 PM EST. SAM.gov, notice 64b1b93b9f374cf89ebdb23e9cfb810d

  2. January 8, 2025

    Combined synopsis and solicitation

    Due January 14, 2025 at 1:00 PM EST. SAM.gov, notice 7c7c03431762414a9835e5d5b64dfef4

Points of contact