Combined synopsis and solicitation, service-disabled veteran-owned small business set-aside
Boiler Steam Safety Valves replaced New Requirement
36C24824Q1138
Department of Veterans Affairs, 248-Network Contract Office 8. Plumbing, Heating, and Air-Conditioning Contractors.
Awarded
$247,359.99 obligated so far on USAspending
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one was awarded in 2024
57 like it are open now in plumbing, heating, and air-conditioning contractors
- Chiller Preventative Maintenance Services
Department of Veterans Affairs, 248-Network Contract Office 8
Combined synopsis and solicitationSDVOSBNAICS 238220Florida36C24827Q0126Closes in 8 daysDec 3 - 13976 PUHO FIRE PROTECTION AT DORM
Departmental Offices, National Park Service Contracting Activity
Sources soughtNAICS 238220Location not published140PP027B0004Due tomorrowNov 26 - AK-AK MARITIME NWR-LEAK REPAIR
Departmental Offices, FWS Contracting Activity
SolicitationSmall businessNAICS 238220Alaska140FF027Q0080Due tomorrowNov 26
All 57 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. Open SDVOSB opportunities
- Time to respond
- Bidders had 30 days from the day the solicitation was posted, June 12, 2024, to the deadline. The deadline moved 2 times: it was first June 21, 2024 and ended as July 12, 2024.
- How it ended
- Awarded to Rjy Group LLC on July 23, 2024, 11 days after offers were due. The contracting office reported 4 offers (competed under simplified acquisition procedures).
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Boiler Steam Safety Valves replacement The purpose of this amendment is to:
1. Questions provided by contractors are due on July 5, 2024, at 12:00pm.
2. Extend the closing date of solicitation to July 12, 2024. Updated Statement of Work is shown below:
Background: The Lake City VA Medical Center in Lake City, Florida has needs to have the Boiler Steam Safety Valves replaced with new cast steel safety valves. The VA is replacing cast iron fittings in the steam system with cast steel fittings. Other deficiencies have been identified and those deficiencies will also be corrected.
Objective: Upgrade the boilers at the Lake City VA to clear all deficiencies identified during routine inspection.
Scope of Work: Coordinate all work with the Contracting Officers Representative (COR) Replace with new, 6 Combustion Air Flow switches. Two on each boiler. Replace with new, 6 Purge Air Flow switches. Two on each boiler. Replace with new, 2 High Gas Pressure switches (1 natural gas, 1 propane) and install Audible Alarm to ring out in the Plant for both. Replace Boiler 3 Disconnect in VFD Panel. Replace Condensate Pump Control Panel and all the internals in that panel. Replace with new, 4 Boiler estops.
One by each door. Replace with new, 2 Pressure Relief Valves for the two reducing stations supplying steam to the DA (cast steel). To include drip pan 90s and the drains run from those 90s. Replace with new, 6 Boiler Steam Safety Valves. Two on each boiler (cast steel). To include drip pain 90s and the drains run from those 90s. Valves shall be sized and installed correctly to meet VA and BEI standards. Re-pipe all 6 Boiler Steam Safety discharge pipes with larger piping.
(Piping must be straight and sized correctly for the safety valves they serve to ensure proper steam discharge from plant.) Test all new safety valves to ensure they are functioning are sized correctly. Valves must pass inspection and meet VA compliance once installed and inspected. All Safety valves shall include drip pan 90s and adequate discharge piping to ensure correct operation per VA standard, BEI standard.
Core bore and repair the new roof penetrations for the new discharge piping. (roof must be resealed) Discharge the new piping through the roof. Terminate discharge piping at same elevation from roof surface as the existing vents. Set and test all new switches to ensure they are functioning and compliant. Provide all documentation to the COR.
Materials: 3 Cast Steel Safety Valves (1 per boiler) Kunkle Model 300 or approved equal Setpoint 145 psi Capacity 6183 lb/hr 3 Cast Steel Safety Valves (1 per boiler) Kunkle Model 300 or approved equal Setpoint 150 psi Capacity 10458 lb/hr 1 Cast Steel Pressure Relief Valve Kunkle Model 300 or approved equal Setpoint 25psi Capacity 2000 lb/hr 1 Cast Steel Pressure Relief Valve Kunkle Model 300 or approved equal Setpoint 60psi Capacity 3700 lb/hr Estops : 4 each 4 pole Emergency Stop Control Stations Pressure Switches: 12 each Antunes Controls JD-2 Red 0.1 24 W.C.
Pressure Switch for Gas in to Boiler Plant: 1 each Ashcroft 0-30 psi Condensate Pump Control Panel All components in the box Disconnect Switch for Boiler 3 Qualifications/Certifications: The Contractor Technician shall possess: Technician shall possess at least five years of experience working on Boilers to perform the services listed in the SOW. The contractor and all individuals working on the project site must have taken the OSHA Certified 10-hour safety course.
Safety Regulations: All OSHA safety regulations shall be observed during the project. The VA Safety Officer shall have full authority to see that the contractor obeys all safety rules and regulations relative to the fulfillment of this project. Provide the necessary barricades/signage where required.
Scheduling and Hours of Work: All work in areas involved shall be scheduled with the COR. The 10 holidays observed by the Federal Government, are New Years Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas or any other day specifically declared by the President of the United States to be a national holiday.
Evaluation/Selection Factor: The project must be performed by a contractor that has the capability and capacity to perform the job. Managerial expertise, technical expertise, past performance, and, cost will be considered.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Rjy Group LLC
- UEI
- N593JWU6B5A7
- CAGE
- 5YJ43
- Vendor location
- Houston, TX
- Contract
- 36C24824P2012, purchase order
- Obligated
- $247,359.99
- Actions
- 2 between July 23, 2024 and September 3, 2024
- Competition
- Competed Under SAP, 4 offers received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- Boiler Room Valves Replacement
- Match
- solicitation number 36C24824Q1138 equals the FPDS solicitation identifier; same awarding office 36C248 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 12, 2024
Combined synopsis and solicitation
Due June 21, 2024 at 3:00 PM EDT. SAM.gov, notice 308b3481a64b4a829d09f55034ce97cc
June 18, 2024
Combined synopsis and solicitation
Due June 28, 2024 at 3:00 PM EDT. SAM.gov, notice 29d41980de374e2bbd65ef8657865e28
June 27, 2024
Combined synopsis and solicitation
Due July 12, 2024 at 3:00 PM EDT. SAM.gov, notice c2d0965c9b01403fa2f9bd086564bb5c
Points of contact
- Jose J Hernandez, Contract Specialistjose.hernandez@va.gov352-381-5708