{"canonical":"https://sealedbidder.com/opportunities/36c24726q0664","key":"36C24726Q0664","url":"https://sealedbidder.com/opportunities/36c24726q0664","title":"H363--Notice of Intent to Sole Source 36C24424Q0045 / 557-26-4-5151-0197 - Building Access Controls Troubleshooting and Repairs","solicitation_number":"36C24726Q0664","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-08T12:00:00Z","first_posted":"2026-07-02","last_posted":"2026-07-02","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"561621","psc":"H363","set_aside":null,"place_state":"GA","place_scope":"site","site":null,"place_state_source":"site","place_evidence":"CCESS CONTROLS SYSTEM AT THE CARL VINSON VA MEDICAL CENTER","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"0eb50253847c46d1aec3530caa063cfd","title":"H363--Notice of Intent to Sole Source 36C24424Q0045 / 557-26-4-5151-0197 - Building Access Controls Troubleshooting and Repairs","solicitation_number":"36C24726Q0664","notice_type":"s","base_type":"s","posted":"2026-07-02","posted_at":"2026-07-02T16:55:43.331Z","due_at":"2026-07-08T12:00:00Z","due_date":"2026-07-08","cancelled":false,"archived":true,"archive_date":"2026-07-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0eb50253847c46d1aec3530caa063cfd/view","enriched":true,"history":[{"index":3,"title":"H363--Notice of Intent to Sole Source 36C24424Q0045 / 557-26-4-5151-0197 - Building Access Controls Troubleshooting and Repairs","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-02T16:55:43.331Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"0eb50253847c46d1aec3530caa063cfd","solicitation_number":"36C24726Q0664"}]}],"latest_notice_id":"0eb50253847c46d1aec3530caa063cfd","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-02","posted_at":"2026-07-02T16:55:43.331Z","created_at":"2026-07-02T16:55:41.132Z","modified_at":"2026-07-14T03:55:53.429Z","response_deadline":{"raw":"2026-07-08T08:00:00-04:00","utc":"2026-07-08T12:00:00Z","date":"2026-07-08","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0eb50253847c46d1aec3530caa063cfd/view"},"naics":{"codes":["561621"],"primary":"561621"},"title":"H363--Notice of Intent to Sole Source 36C24424Q0045 / 557-26-4-5151-0197 - Building Access Controls Troubleshooting and Repairs","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"H363--Notice of Intent to Sole Source 36C24424Q0045 / 557-26-4-5151-0197 - Building Access Controls Troubleshooting and Repairs","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-02T16:55:43.331Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"0eb50253847c46d1aec3530caa063cfd","solicitation_number":"36C24726Q0664"}],"contacts":[{"name":"Scottie Scott","role":"primary","email":"scottie.scott@va.gov","phone":"(803) 776-4000","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"0eb50253847c46d1aec3530caa063cfd","lineage_id":"0eb50253847c46d1aec3530caa063cfd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T11:48:31.991449026Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"9cf14b73c7ae65856ad7cf6ab813dac8a8ac7b7f3666dc08a3e2fcc77248110a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T11:48:31.991449026Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Building Access Controls and Site Security Repairs\n\n\n\nNOTICE OF INTENT TO SOLE SOURCE: \n\n\nIAW FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs Network Contracting Office 7, intends to award a sole source, Firm-Fixed-Price Contract to Convergint Technologies LLC. Per FAR 12.102 (a) VA to usage of Avigilon security camera monitoring system, facility security services are seeking a vendor licensed to work with Avigilon products. Of those that are licensed to work on/with Avigilon products, Convergint has prior experience working with facility security systems and, thus, has intimate knowledge of current facility security situations and needs. Any unforeseen concerns could lead to further delays of assessments and corrective actions that have already been stalled.\n\n\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS:\n\n\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Scottie Scott, Contract Specialist, scottie.scott@va.gov. Telephone inquiries will not be accepted.\n\n\n\n\n\n\n\n\n\nStatement of Work\n\n1826 Veterans Blvd\nDublin, GA 31021\n\nScope\n\nThe vendor will provide all supervision, labor, equipment, and materials needed to complete work for this service contract per this SOW. Work will consist of troubleshooting and repairing the camera system and access controls system at the Carl Vinson VA Medical Center (CVVAMC). All work must be in accordance with applicable local, state, and federal codes, rules, and regulations. Impact shall be minimized and mitigated in a way that limits disruption to the functioning of the Medical Center. Scheduling and coordination with the CVVAMC will be critical and must be coordinated and approved by Contracting Officer s Representative (COR). \n\nCurrent systems are Avigilon ACC 7 for camera monitoring and Software House Tyco C-Cure 9000 with HID Signo Readers for access controls.\n\nThe work shall include: \n\nThe vendor shall document all identified deficiencies, provide written recommendations for remediation, and perform on-the-spot corrective actions for any issues that can be resolved within the authorized labor window without procurement of additional equipment or materials.\nLog in to the ACC7-Enterprise VMS console and review device status, error logs, and communication alerts for all offline or faulty cameras.\nIdentify cameras that are fully offline versus cameras showing degraded status (poor image quality, intermittent connectivity, etc.).\nPhysically inspect each non-functional camera for visible damage, connector integrity, and mounting condition.\nTest and verify Power over Ethernet (PoE) delivery at each camera drop; confirm switch port status and PoE budget utilization.\nTest network path continuity from each camera back to the VMS server, including patch panels, switches, and cabling segments.\nVerify camera IP addressing, subnet mask, gateway, and VMS server communication settings via the ACC7-Enterprise device configuration panel.\nAttempt firmware-level camera resets and re-discovery within ACC7-Enterprise where appropriate.\nDocument each camera by location, equipment tag/serial number, deficiency type, and recommended corrective action.\nthe fiber pathway. \nIdentify and trace the complete fiber run from the tower camera enclosures back to the nearest IDF/MDF termination point.\nInspect all fiber connectors, patch cords, splice enclosures, and junction boxes along the tower fiber route for damage, contamination, or improper termination.\nUse an Optical Time-Domain Reflectometer (OTDR) or optical light source/power meter to test fiber strand continuity, insertion loss, and identify any breaks or high-loss events.\nInspect the media converter(s) or fiber-to-copper transceiver(s) associated with the tower cameras; verify power, link indicators, and device configuration.\nCheck the fiber patch panel terminations at the headend for proper connector seating and contamination.\nVerify that fiber strands are correctly mapped and cross-connected to the appropriate camera feeds.\nIf fiber damage or a faulty connector is found and a repair can be completed within the authorized scope (e.g., connector re-termination, patch cord replacement), technicians shall perform the repair immediately.\nDocument all findings, including OTDR trace results, loss measurements, and recommendations for any repairs requiring specialized equipment or materials outside this scope.\nAccess the CC9000 PACS management software and review the current status, event logs, and hardware diagnostics for all reported non-functional readers.\nIdentify and record each reader by door name, controller address, and reader port assignment as reflected in the CC9000 database.\nPhysically inspect each card reader for visible damage, LED status indicators, and proper mounting.\nVerify wiring integrity at each reader including power, data (Wiegand/OSDP), and ground conductors. Use a multimeter to measure voltage and continuity on each conductor pair.\nInspect the associated access control panel (ACP) or sub-controller for each reader: verify power supply voltage, communication bus status, and LED/diagnostic indicators.\nConfirm reader addresses, communication protocol settings (Wiegand vs. OSDP), and tamper switch status within the CC9000 configuration.\nTest reader functionality using a known valid credential after any corrective action.\nInspect door hardware (REX, door contacts, locks) to determine if associated peripheral devices may be contributing to reader or controller faults.\nDocument each reader/controller by location, equipment ID, fault type, corrective action taken, and any recommended follow-up.\nProvide CC9000 software support (to include firmware and software updates, technical support for system troubleshooting, and software upgrades) for one year.\n\nQualifications\nAll personnel performing work under this Scope of Work shall meet the following minimum qualifications:\n\nDemonstrated, hands-on experience with Avigilon IP camera systems and ACC7-Enterprise VMS administration.\nDemonstrated, hands-on experience with CC9000 PACS hardware and software configuration.\nProficiency in structured cabling, fiber optic testing (OTDR operation), and low-voltage electrical troubleshooting.\nPhysical ability to work at heights if tower access is required to inspect fiber termination points at the tower base or intermediate junction enclosures.\n\nDeliverables\n#\nDeliverable\nContents\n1\nDeficiency Assessment Report\n(Additional information provided below)\nExecutive summary, complete deficiency log for all cameras\nand card readers, FboNotice cause findings, and photographs.\n2\nCorrective Action Summary\nItemized list of all corrective actions performed on-site,\nincluding pre- and post-repair status for each device.\n3\nOpen Items & Recommendations\nPrioritized list of unresolved deficiencies with specific\nrecommended remediation steps, required materials, and\nestimated labor to complete.\n4\nTime and Labor Log\nTechnician name(s), daily start/end times, tasks performed,\nand cumulative hours applied.\n\n\nDeficiency Assessment Report\n#\nInformation\nDescription\n1\nLocation/Area\nBuilding number, room name, floor, and nearest landmark or\ndoor number.\n2\nEquipment Info\nManufacturer, model number, serial number, and\nasset/equipment tag.\n3\nSystem\nVMS (Avigilon ACC7-Enterprise) or PACS (CC9000), as\napplicable.\n4\nDeficiency\nClear description of the observed fault or failure condition.\n5\nRoot Cause\nTechnician s determination of the probable cause of the\ndeficiency.\n6\nAction Taken\nDescription of any corrective actions performed during this visit.\n7\nResolution\nResolved, Partially Resolved, or Requires Follow-Up.\n8\nRecommendation\nSpecific recommended action(s) required to fully remediate\nunresolved deficiencies.\n9\nMaterials/ Equipment Required\nList of parts, equipment, or specialty tools needed for full\nresolution.\n10\nTechnician and Date\nName of technician performing assessment and date/time of\ninspection.\n\n\nRepair Contingency\n\nThe VA shall authorize a repair contingency fund not to exceed $17,869.00 for use at the discretion of the COR for immediate, necessary system repairs. The contractor must notify the COR of the known deficiency/repair and provide a detailed (labor, materials, travel, etc.) cost estimate. The contractor must receive approval from the CO and COR before conducting the work.  \n\nDeficiencies identified by VA employees or third-party inspections, audits, etc. may also be repaired under this contingency. \n\n\nGeneral Requirements \n\nEmployees of the vendor and sub-contractors shall always conduct themselves in a professional manner while on medical center property. The vendor shall ensure all personnel working on this contract are aware of Medical Center rules pertaining to employee behavior and conduct.\n\nPhysical or verbal misconduct may be grounds for removing employees from Medical Center property, or grounds for arrest by the VA Police. Employees may be banned from Medical Center property because of inappropriate or illegal behavior. The vendor shall not be entitled to any compensation from the Government for any costs resulting from employee misconduct (including, but not limited to, delays in contract completion) and may be held liable for costs incurred by the Government because of employee misconduct.\n\nTobacco Use is 100% prohibited on all VA property. \n\nThe VA will not be responsible for storage of equipment, materials, or tools.  \n\nIt is the vendor s responsibility to properly assess the working conditions and include in the bid any specialty equipment, training, additional time, personnel, or safety equipment to perform the work safely and in compliance with all applicable local, State, and Federal regulations. \n\nIf any damage is done to the property and building, by the vendor, the vendor is fully responsible for bearing the costs of repair and interim costs for maintaining medical center operations.\n\nHours of Work\n\nNormal working hours are 0700   1600 Monday to Friday, except for federal holidays.  Preparation can be done during these hours.  To reduce patient impact, all work that requires a utility outage will need to take place during afterhours (1700   0500) or during weekends.  All work started shall be completed and the work area(s) ready for full operations no later than 0500 the following day, unless otherwise coordinated with the COR.  All schedules and work hours shall be requested, coordinated, and approved through the COR.  \n\nSecurity\n\nNo badging is required for this requirement due to lack of need for vendor to be working onsite without VA supervision.\n\nSafety\n\nWhenever executing work within the proximity of live electrical equipment (including testing, voltage/current measurements, infrared scans, ultrasonic scans, and/or verifying a de-energized condition prior to performing work), the vendor shall provide and wear full and proper Personal Protective Equipment per the requirements of VHA Directive 1028, NFPA 70E.  The vendor must also provide all lockout/tagout equipment required to secure electrical safe work conditions.  \n\nReferences \n\nContractors shall have ready access to the latest versions of the following references: \n\nNFPA 70B, Recommended Practice for Electrical Equipment Maintenance\nNFPA 70E, Standard for Electrical Safety in the Workplace\nOSHA Standard 29 CFR 1910\n\n\nParking/Laydown Area\n\nThe vendor shall coordinate with the COR for parking at the facility. The vendor shall communicate the amount of space. At no time shall vehicles be parked on roadways, patient parking areas, the loading dock, etc.  \n\n\nPeriod of Performance\n\nPeriod of Performance is 365 calendar days.\n\nHospital operations shall take priority. Vendor shall do everything feasible to ensure the continuation of hospital operations.","text":"Building Access Controls and Site Security Repairs\n\nNOTICE OF INTENT TO SOLE SOURCE:\n\nIAW FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs Network Contracting Office 7, intends to award a sole source, Firm-Fixed-Price Contract to Convergint Technologies LLC. Per FAR 12.102 (a) VA to usage of Avigilon security camera monitoring system, facility security services are seeking a vendor licensed to work with Avigilon products. Of those that are licensed to work on/with Avigilon products, Convergint has prior experience working with facility security systems and, thus, has intimate knowledge of current facility security situations and needs. Any unforeseen concerns could lead to further delays of assessments and corrective actions that have already been stalled.\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS:\n\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Scottie Scott, Contract Specialist, scottie.scott@va.gov. Telephone inquiries will not be accepted.\n\nStatement of Work\n\n1826 Veterans Blvd\nDublin, GA 31021\n\nScope\n\nThe vendor will provide all supervision, labor, equipment, and materials needed to complete work for this service contract per this SOW. Work will consist of troubleshooting and repairing the camera system and access controls system at the Carl Vinson VA Medical Center (CVVAMC). All work must be in accordance with applicable local, state, and federal codes, rules, and regulations. Impact shall be minimized and mitigated in a way that limits disruption to the functioning of the Medical Center. Scheduling and coordination with the CVVAMC will be critical and must be coordinated and approved by Contracting Officer s Representative (COR).\n\nCurrent systems are Avigilon ACC 7 for camera monitoring and Software House Tyco C-Cure 9000 with HID Signo Readers for access controls.\n\nThe work shall include:\n\nThe vendor shall document all identified deficiencies, provide written recommendations for remediation, and perform on-the-spot corrective actions for any issues that can be resolved within the authorized labor window without procurement of additional equipment or materials.\nLog in to the ACC7-Enterprise VMS console and review device status, error logs, and communication alerts for all offline or faulty cameras.\nIdentify cameras that are fully offline versus cameras showing degraded status (poor image quality, intermittent connectivity, etc.).\nPhysically inspect each non-functional camera for visible damage, connector integrity, and mounting condition.\nTest and verify Power over Ethernet (PoE) delivery at each camera drop; confirm switch port status and PoE budget utilization.\nTest network path continuity from each camera back to the VMS server, including patch panels, switches, and cabling segments.\nVerify camera IP addressing, subnet mask, gateway, and VMS server communication settings via the ACC7-Enterprise device configuration panel.\nAttempt firmware-level camera resets and re-discovery within ACC7-Enterprise where appropriate.\nDocument each camera by location, equipment tag/serial number, deficiency type, and recommended corrective action.\nthe fiber pathway.\nIdentify and trace the complete fiber run from the tower camera enclosures back to the nearest IDF/MDF termination point.\nInspect all fiber connectors, patch cords, splice enclosures, and junction boxes along the tower fiber route for damage, contamination, or improper termination.\nUse an Optical Time-Domain Reflectometer (OTDR) or optical light source/power meter to test fiber strand continuity, insertion loss, and identify any breaks or high-loss events.\nInspect the media converter(s) or fiber-to-copper transceiver(s) associated with the tower cameras; verify power, link indicators, and device configuration.\nCheck the fiber patch panel terminations at the headend for proper connector seating and contamination.\nVerify that fiber strands are correctly mapped and cross-connected to the appropriate camera feeds.\nIf fiber damage or a faulty connector is found and a repair can be completed within the authorized scope (e.g., connector re-termination, patch cord replacement), technicians shall perform the repair immediately.\nDocument all findings, including OTDR trace results, loss measurements, and recommendations for any repairs requiring specialized equipment or materials outside this scope.\nAccess the CC9000 PACS management software and review the current status, event logs, and hardware diagnostics for all reported non-functional readers.\nIdentify and record each reader by door name, controller address, and reader port assignment as reflected in the CC9000 database.\nPhysically inspect each card reader for visible damage, LED status indicators, and proper mounting.\nVerify wiring integrity at each reader including power, data (Wiegand/OSDP), and ground conductors. Use a multimeter to measure voltage and continuity on each conductor pair.\nInspect the associated access control panel (ACP) or sub-controller for each reader: verify power supply voltage, communication bus status, and LED/diagnostic indicators.\nConfirm reader addresses, communication protocol settings (Wiegand vs. OSDP), and tamper switch status within the CC9000 configuration.\nTest reader functionality using a known valid credential after any corrective action.\nInspect door hardware (REX, door contacts, locks) to determine if associated peripheral devices may be contributing to reader or controller faults.\nDocument each reader/controller by location, equipment ID, fault type, corrective action taken, and any recommended follow-up.\nProvide CC9000 software support (to include firmware and software updates, technical support for system troubleshooting, and software upgrades) for one year.\n\nQualifications\nAll personnel performing work under this Scope of Work shall meet the following minimum qualifications:\n\nDemonstrated, hands-on experience with Avigilon IP camera systems and ACC7-Enterprise VMS administration.\nDemonstrated, hands-on experience with CC9000 PACS hardware and software configuration.\nProficiency in structured cabling, fiber optic testing (OTDR operation), and low-voltage electrical troubleshooting.\nPhysical ability to work at heights if tower access is required to inspect fiber termination points at the tower base or intermediate junction enclosures.\n\nDeliverables\n#\nDeliverable\nContents\n1\nDeficiency Assessment Report\n(Additional information provided below)\nExecutive summary, complete deficiency log for all cameras\nand card readers, FboNotice cause findings, and photographs.\n2\nCorrective Action Summary\nItemized list of all corrective actions performed on-site,\nincluding pre- and post-repair status for each device.\n3\nOpen Items & Recommendations\nPrioritized list of unresolved deficiencies with specific\nrecommended remediation steps, required materials, and\nestimated labor to complete.\n4\nTime and Labor Log\nTechnician name(s), daily start/end times, tasks performed,\nand cumulative hours applied.\n\nDeficiency Assessment Report\n#\nInformation\nDescription\n1\nLocation/Area\nBuilding number, room name, floor, and nearest landmark or\ndoor number.\n2\nEquipment Info\nManufacturer, model number, serial number, and\nasset/equipment tag.\n3\nSystem\nVMS (Avigilon ACC7-Enterprise) or PACS (CC9000), as\napplicable.\n4\nDeficiency\nClear description of the observed fault or failure condition.\n5\nRoot Cause\nTechnician s determination of the probable cause of the\ndeficiency.\n6\nAction Taken\nDescription of any corrective actions performed during this visit.\n7\nResolution\nResolved, Partially Resolved, or Requires Follow-Up.\n8\nRecommendation\nSpecific recommended action(s) required to fully remediate\nunresolved deficiencies.\n9\nMaterials/ Equipment Required\nList of parts, equipment, or specialty tools needed for full\nresolution.\n10\nTechnician and Date\nName of technician performing assessment and date/time of\ninspection.\n\nRepair Contingency\n\nThe VA shall authorize a repair contingency fund not to exceed $17,869.00 for use at the discretion of the COR for immediate, necessary system repairs. The contractor must notify the COR of the known deficiency/repair and provide a detailed (labor, materials, travel, etc.) cost estimate. The contractor must receive approval from the CO and COR before conducting the work.\n\nDeficiencies identified by VA employees or third-party inspections, audits, etc. may also be repaired under this contingency.\n\nGeneral Requirements\n\nEmployees of the vendor and sub-contractors shall always conduct themselves in a professional manner while on medical center property. The vendor shall ensure all personnel working on this contract are aware of Medical Center rules pertaining to employee behavior and conduct.\n\nPhysical or verbal misconduct may be grounds for removing employees from Medical Center property, or grounds for arrest by the VA Police. Employees may be banned from Medical Center property because of inappropriate or illegal behavior. The vendor shall not be entitled to any compensation from the Government for any costs resulting from employee misconduct (including, but not limited to, delays in contract completion) and may be held liable for costs incurred by the Government because of employee misconduct.\n\nTobacco Use is 100% prohibited on all VA property.\n\nThe VA will not be responsible for storage of equipment, materials, or tools.\n\nIt is the vendor s responsibility to properly assess the working conditions and include in the bid any specialty equipment, training, additional time, personnel, or safety equipment to perform the work safely and in compliance with all applicable local, State, and Federal regulations.\n\nIf any damage is done to the property and building, by the vendor, the vendor is fully responsible for bearing the costs of repair and interim costs for maintaining medical center operations.\n\nHours of Work\n\nNormal working hours are 0700 1600 Monday to Friday, except for federal holidays. Preparation can be done during these hours. To reduce patient impact, all work that requires a utility outage will need to take place during afterhours (1700 0500) or during weekends. All work started shall be completed and the work area(s) ready for full operations no later than 0500 the following day, unless otherwise coordinated with the COR. All schedules and work hours shall be requested, coordinated, and approved through the COR.\n\nSecurity\n\nNo badging is required for this requirement due to lack of need for vendor to be working onsite without VA supervision.\n\nSafety\n\nWhenever executing work within the proximity of live electrical equipment (including testing, voltage/current measurements, infrared scans, ultrasonic scans, and/or verifying a de-energized condition prior to performing work), the vendor shall provide and wear full and proper Personal Protective Equipment per the requirements of VHA Directive 1028, NFPA 70E. The vendor must also provide all lockout/tagout equipment required to secure electrical safe work conditions.\n\nReferences\n\nContractors shall have ready access to the latest versions of the following references:\n\nNFPA 70B, Recommended Practice for Electrical Equipment Maintenance\nNFPA 70E, Standard for Electrical Safety in the Workplace\nOSHA Standard 29 CFR 1910\n\nParking/Laydown Area\n\nThe vendor shall coordinate with the COR for parking at the facility. The vendor shall communicate the amount of space. At no time shall vehicles be parked on roadways, patient parking areas, the loading dock, etc.\n\nPeriod of Performance\n\nPeriod of Performance is 365 calendar days.\n\nHospital operations shall take priority. Vendor shall do everything feasible to ensure the continuation of hospital operations.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24726Q0664","product_service_code":"H363"}],"due_at":"2026-07-08T12:00:00Z","due_date":"2026-07-08","closes_at":"2026-07-08T12:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","state":"GA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"site","state_evidence":"CCESS CONTROLS SYSTEM AT THE CARL VINSON VA MEDICAL CENTER","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T08:08:23.148393Z","principal_notice_id":"0eb50253847c46d1aec3530caa063cfd","description":{"text":"Building Access Controls and Site Security Repairs\n\nNOTICE OF INTENT TO SOLE SOURCE:\n\nIAW FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs Network Contracting Office 7, intends to award a sole source, Firm-Fixed-Price Contract to Convergint Technologies LLC. Per FAR 12.102 (a) VA to usage of Avigilon security camera monitoring system, facility security services are seeking a vendor licensed to work with Avigilon products. Of those that are licensed to work on/with Avigilon products, Convergint has prior experience working with facility security systems and, thus, has intimate knowledge of current facility security situations and needs. Any unforeseen concerns could lead to further delays of assessments and corrective actions that have already been stalled.\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS:\n\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Scottie Scott, Contract Specialist, scottie.scott@va.gov. Telephone inquiries will not be accepted.\n\nStatement of Work\n\n1826 Veterans Blvd\nDublin, GA 31021\n\nScope\n\nThe vendor will provide all supervision, labor, equipment, and materials needed to complete work for this service contract per this SOW. Work will consist of troubleshooting and repairing the camera system and access controls system at the Carl Vinson VA Medical Center (CVVAMC). All work must be in accordance with applicable local, state, and federal codes, rules, and regulations. Impact shall be minimized and mitigated in a way that limits disruption to the functioning of the Medical Center. Scheduling and coordination with the CVVAMC will be critical and must be coordinated and approved by Contracting Officer s Representative (COR).\n\nCurrent systems are Avigilon ACC 7 for camera monitoring and Software House Tyco C-Cure 9000 with HID Signo Readers for access controls.\n\nThe work shall include:\n\nThe vendor shall document all identified deficiencies, provide written recommendations for remediation, and perform on-the-spot corrective actions for any issues that can be resolved within the authorized labor window without procurement of additional equipment or materials.\nLog in to the ACC7-Enterprise VMS console and review device status, error logs, and communication alerts for all offline or faulty cameras.\nIdentify cameras that are fully offline versus cameras showing degraded status (poor image quality, intermittent connectivity, etc.).\nPhysically inspect each non-functional camera for visible damage, connector integrity, and mounting condition.\nTest and verify Power over Ethernet (PoE) delivery at each camera drop; confirm switch port status and PoE budget utilization.\nTest network path continuity from each camera back to the VMS server, including patch panels, switches, and cabling segments.\nVerify camera IP addressing, subnet mask, gateway, and VMS server communication settings via the ACC7-Enterprise device configuration panel.\nAttempt firmware-level camera resets and re-discovery within ACC7-Enterprise where appropriate.\nDocument each camera by location, equipment tag/serial number, deficiency type, and recommended corrective action.\nthe fiber pathway.\nIdentify and trace the complete fiber run from the tower camera enclosures back to the nearest IDF/MDF termination point.\nInspect all fiber connectors, patch cords, splice enclosures, and junction boxes along the tower fiber route for damage, contamination, or improper termination.\nUse an Optical Time-Domain Reflectometer (OTDR) or optical light source/power meter to test fiber strand continuity, insertion loss, and identify any breaks or high-loss events.\nInspect the media converter(s) or fiber-to-copper transceiver(s) associated with the tower cameras; verify power, link indicators, and device configuration.\nCheck the fiber patch panel terminations at the headend for proper connector seating and contamination.\nVerify that fiber strands are correctly mapped and cross-connected to the appropriate camera feeds.\nIf fiber damage or a faulty connector is found and a repair can be completed within the authorized scope (e.g., connector re-termination, patch cord replacement), technicians shall perform the repair immediately.\nDocument all findings, including OTDR trace results, loss measurements, and recommendations for any repairs requiring specialized equipment or materials outside this scope.\nAccess the CC9000 PACS management software and review the current status, event logs, and hardware diagnostics for all reported non-functional readers.\nIdentify and record each reader by door name, controller address, and reader port assignment as reflected in the CC9000 database.\nPhysically inspect each card reader for visible damage, LED status indicators, and proper mounting.\nVerify wiring integrity at each reader including power, data (Wiegand/OSDP), and ground conductors. Use a multimeter to measure voltage and continuity on each conductor pair.\nInspect the associated access control panel (ACP) or sub-controller for each reader: verify power supply voltage, communication bus status, and LED/diagnostic indicators.\nConfirm reader addresses, communication protocol settings (Wiegand vs. OSDP), and tamper switch status within the CC9000 configuration.\nTest reader functionality using a known valid credential after any corrective action.\nInspect door hardware (REX, door contacts, locks) to determine if associated peripheral devices may be contributing to reader or controller faults.\nDocument each reader/controller by location, equipment ID, fault type, corrective action taken, and any recommended follow-up.\nProvide CC9000 software support (to include firmware and software updates, technical support for system troubleshooting, and software upgrades) for one year.\n\nQualifications\nAll personnel performing work under this Scope of Work shall meet the following minimum qualifications:\n\nDemonstrated, hands-on experience with Avigilon IP camera systems and ACC7-Enterprise VMS administration.\nDemonstrated, hands-on experience with CC9000 PACS hardware and software configuration.\nProficiency in structured cabling, fiber optic testing (OTDR operation), and low-voltage electrical troubleshooting.\nPhysical ability to work at heights if tower access is required to inspect fiber termination points at the tower base or intermediate junction enclosures.\n\nDeliverables\n#\nDeliverable\nContents\n1\nDeficiency Assessment Report\n(Additional information provided below)\nExecutive summary, complete deficiency log for all cameras\nand card readers, FboNotice cause findings, and photographs.\n2\nCorrective Action Summary\nItemized list of all corrective actions performed on-site,\nincluding pre- and post-repair status for each device.\n3\nOpen Items & Recommendations\nPrioritized list of unresolved deficiencies with specific\nrecommended remediation steps, required materials, and\nestimated labor to complete.\n4\nTime and Labor Log\nTechnician name(s), daily start/end times, tasks performed,\nand cumulative hours applied.\n\nDeficiency Assessment Report\n#\nInformation\nDescription\n1\nLocation/Area\nBuilding number, room name, floor, and nearest landmark or\ndoor number.\n2\nEquipment Info\nManufacturer, model number, serial number, and\nasset/equipment tag.\n3\nSystem\nVMS (Avigilon ACC7-Enterprise) or PACS (CC9000), as\napplicable.\n4\nDeficiency\nClear description of the observed fault or failure condition.\n5\nRoot Cause\nTechnician s determination of the probable cause of the\ndeficiency.\n6\nAction Taken\nDescription of any corrective actions performed during this visit.\n7\nResolution\nResolved, Partially Resolved, or Requires Follow-Up.\n8\nRecommendation\nSpecific recommended action(s) required to fully remediate\nunresolved deficiencies.\n9\nMaterials/ Equipment Required\nList of parts, equipment, or specialty tools needed for full\nresolution.\n10\nTechnician and Date\nName of technician performing assessment and date/time of\ninspection.\n\nRepair Contingency\n\nThe VA shall authorize a repair contingency fund not to exceed $17,869.00 for use at the discretion of the COR for immediate, necessary system repairs. The contractor must notify the COR of the known deficiency/repair and provide a detailed (labor, materials, travel, etc.) cost estimate. The contractor must receive approval from the CO and COR before conducting the work.\n\nDeficiencies identified by VA employees or third-party inspections, audits, etc. may also be repaired under this contingency.\n\nGeneral Requirements\n\nEmployees of the vendor and sub-contractors shall always conduct themselves in a professional manner while on medical center property. The vendor shall ensure all personnel working on this contract are aware of Medical Center rules pertaining to employee behavior and conduct.\n\nPhysical or verbal misconduct may be grounds for removing employees from Medical Center property, or grounds for arrest by the VA Police. Employees may be banned from Medical Center property because of inappropriate or illegal behavior. The vendor shall not be entitled to any compensation from the Government for any costs resulting from employee misconduct (including, but not limited to, delays in contract completion) and may be held liable for costs incurred by the Government because of employee misconduct.\n\nTobacco Use is 100% prohibited on all VA property.\n\nThe VA will not be responsible for storage of equipment, materials, or tools.\n\nIt is the vendor s responsibility to properly assess the working conditions and include in the bid any specialty equipment, training, additional time, personnel, or safety equipment to perform the work safely and in compliance with all applicable local, State, and Federal regulations.\n\nIf any damage is done to the property and building, by the vendor, the vendor is fully responsible for bearing the costs of repair and interim costs for maintaining medical center operations.\n\nHours of Work\n\nNormal working hours are 0700 1600 Monday to Friday, except for federal holidays. Preparation can be done during these hours. To reduce patient impact, all work that requires a utility outage will need to take place during afterhours (1700 0500) or during weekends. All work started shall be completed and the work area(s) ready for full operations no later than 0500 the following day, unless otherwise coordinated with the COR. All schedules and work hours shall be requested, coordinated, and approved through the COR.\n\nSecurity\n\nNo badging is required for this requirement due to lack of need for vendor to be working onsite without VA supervision.\n\nSafety\n\nWhenever executing work within the proximity of live electrical equipment (including testing, voltage/current measurements, infrared scans, ultrasonic scans, and/or verifying a de-energized condition prior to performing work), the vendor shall provide and wear full and proper Personal Protective Equipment per the requirements of VHA Directive 1028, NFPA 70E. The vendor must also provide all lockout/tagout equipment required to secure electrical safe work conditions.\n\nReferences\n\nContractors shall have ready access to the latest versions of the following references:\n\nNFPA 70B, Recommended Practice for Electrical Equipment Maintenance\nNFPA 70E, Standard for Electrical Safety in the Workplace\nOSHA Standard 29 CFR 1910\n\nParking/Laydown Area\n\nThe vendor shall coordinate with the COR for parking at the facility. The vendor shall communicate the amount of space. At no time shall vehicles be parked on roadways, patient parking areas, the loading dock, etc.\n\nPeriod of Performance\n\nPeriod of Performance is 365 calendar days.\n\nHospital operations shall take priority. Vendor shall do everything feasible to ensure the continuation of hospital operations.","html":"Building Access Controls and Site Security Repairs\n\n\n\nNOTICE OF INTENT TO SOLE SOURCE: \n\n\nIAW FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs Network Contracting Office 7, intends to award a sole source, Firm-Fixed-Price Contract to Convergint Technologies LLC. Per FAR 12.102 (a) VA to usage of Avigilon security camera monitoring system, facility security services are seeking a vendor licensed to work with Avigilon products. Of those that are licensed to work on/with Avigilon products, Convergint has prior experience working with facility security systems and, thus, has intimate knowledge of current facility security situations and needs. Any unforeseen concerns could lead to further delays of assessments and corrective actions that have already been stalled.\n\n\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS:\n\n\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Scottie Scott, Contract Specialist, scottie.scott@va.gov. Telephone inquiries will not be accepted.\n\n\n\n\n\n\n\n\n\nStatement of Work\n\n1826 Veterans Blvd\nDublin, GA 31021\n\nScope\n\nThe vendor will provide all supervision, labor, equipment, and materials needed to complete work for this service contract per this SOW. Work will consist of troubleshooting and repairing the camera system and access controls system at the Carl Vinson VA Medical Center (CVVAMC). All work must be in accordance with applicable local, state, and federal codes, rules, and regulations. Impact shall be minimized and mitigated in a way that limits disruption to the functioning of the Medical Center. Scheduling and coordination with the CVVAMC will be critical and must be coordinated and approved by Contracting Officer s Representative (COR). \n\nCurrent systems are Avigilon ACC 7 for camera monitoring and Software House Tyco C-Cure 9000 with HID Signo Readers for access controls.\n\nThe work shall include: \n\nThe vendor shall document all identified deficiencies, provide written recommendations for remediation, and perform on-the-spot corrective actions for any issues that can be resolved within the authorized labor window without procurement of additional equipment or materials.\nLog in to the ACC7-Enterprise VMS console and review device status, error logs, and communication alerts for all offline or faulty cameras.\nIdentify cameras that are fully offline versus cameras showing degraded status (poor image quality, intermittent connectivity, etc.).\nPhysically inspect each non-functional camera for visible damage, connector integrity, and mounting condition.\nTest and verify Power over Ethernet (PoE) delivery at each camera drop; confirm switch port status and PoE budget utilization.\nTest network path continuity from each camera back to the VMS server, including patch panels, switches, and cabling segments.\nVerify camera IP addressing, subnet mask, gateway, and VMS server communication settings via the ACC7-Enterprise device configuration panel.\nAttempt firmware-level camera resets and re-discovery within ACC7-Enterprise where appropriate.\nDocument each camera by location, equipment tag/serial number, deficiency type, and recommended corrective action.\nthe fiber pathway. \nIdentify and trace the complete fiber run from the tower camera enclosures back to the nearest IDF/MDF termination point.\nInspect all fiber connectors, patch cords, splice enclosures, and junction boxes along the tower fiber route for damage, contamination, or improper termination.\nUse an Optical Time-Domain Reflectometer (OTDR) or optical light source/power meter to test fiber strand continuity, insertion loss, and identify any breaks or high-loss events.\nInspect the media converter(s) or fiber-to-copper transceiver(s) associated with the tower cameras; verify power, link indicators, and device configuration.\nCheck the fiber patch panel terminations at the headend for proper connector seating and contamination.\nVerify that fiber strands are correctly mapped and cross-connected to the appropriate camera feeds.\nIf fiber damage or a faulty connector is found and a repair can be completed within the authorized scope (e.g., connector re-termination, patch cord replacement), technicians shall perform the repair immediately.\nDocument all findings, including OTDR trace results, loss measurements, and recommendations for any repairs requiring specialized equipment or materials outside this scope.\nAccess the CC9000 PACS management software and review the current status, event logs, and hardware diagnostics for all reported non-functional readers.\nIdentify and record each reader by door name, controller address, and reader port assignment as reflected in the CC9000 database.\nPhysically inspect each card reader for visible damage, LED status indicators, and proper mounting.\nVerify wiring integrity at each reader including power, data (Wiegand/OSDP), and ground conductors. Use a multimeter to measure voltage and continuity on each conductor pair.\nInspect the associated access control panel (ACP) or sub-controller for each reader: verify power supply voltage, communication bus status, and LED/diagnostic indicators.\nConfirm reader addresses, communication protocol settings (Wiegand vs. OSDP), and tamper switch status within the CC9000 configuration.\nTest reader functionality using a known valid credential after any corrective action.\nInspect door hardware (REX, door contacts, locks) to determine if associated peripheral devices may be contributing to reader or controller faults.\nDocument each reader/controller by location, equipment ID, fault type, corrective action taken, and any recommended follow-up.\nProvide CC9000 software support (to include firmware and software updates, technical support for system troubleshooting, and software upgrades) for one year.\n\nQualifications\nAll personnel performing work under this Scope of Work shall meet the following minimum qualifications:\n\nDemonstrated, hands-on experience with Avigilon IP camera systems and ACC7-Enterprise VMS administration.\nDemonstrated, hands-on experience with CC9000 PACS hardware and software configuration.\nProficiency in structured cabling, fiber optic testing (OTDR operation), and low-voltage electrical troubleshooting.\nPhysical ability to work at heights if tower access is required to inspect fiber termination points at the tower base or intermediate junction enclosures.\n\nDeliverables\n#\nDeliverable\nContents\n1\nDeficiency Assessment Report\n(Additional information provided below)\nExecutive summary, complete deficiency log for all cameras\nand card readers, FboNotice cause findings, and photographs.\n2\nCorrective Action Summary\nItemized list of all corrective actions performed on-site,\nincluding pre- and post-repair status for each device.\n3\nOpen Items & Recommendations\nPrioritized list of unresolved deficiencies with specific\nrecommended remediation steps, required materials, and\nestimated labor to complete.\n4\nTime and Labor Log\nTechnician name(s), daily start/end times, tasks performed,\nand cumulative hours applied.\n\n\nDeficiency Assessment Report\n#\nInformation\nDescription\n1\nLocation/Area\nBuilding number, room name, floor, and nearest landmark or\ndoor number.\n2\nEquipment Info\nManufacturer, model number, serial number, and\nasset/equipment tag.\n3\nSystem\nVMS (Avigilon ACC7-Enterprise) or PACS (CC9000), as\napplicable.\n4\nDeficiency\nClear description of the observed fault or failure condition.\n5\nRoot Cause\nTechnician s determination of the probable cause of the\ndeficiency.\n6\nAction Taken\nDescription of any corrective actions performed during this visit.\n7\nResolution\nResolved, Partially Resolved, or Requires Follow-Up.\n8\nRecommendation\nSpecific recommended action(s) required to fully remediate\nunresolved deficiencies.\n9\nMaterials/ Equipment Required\nList of parts, equipment, or specialty tools needed for full\nresolution.\n10\nTechnician and Date\nName of technician performing assessment and date/time of\ninspection.\n\n\nRepair Contingency\n\nThe VA shall authorize a repair contingency fund not to exceed $17,869.00 for use at the discretion of the COR for immediate, necessary system repairs. The contractor must notify the COR of the known deficiency/repair and provide a detailed (labor, materials, travel, etc.) cost estimate. The contractor must receive approval from the CO and COR before conducting the work.  \n\nDeficiencies identified by VA employees or third-party inspections, audits, etc. may also be repaired under this contingency. \n\n\nGeneral Requirements \n\nEmployees of the vendor and sub-contractors shall always conduct themselves in a professional manner while on medical center property. The vendor shall ensure all personnel working on this contract are aware of Medical Center rules pertaining to employee behavior and conduct.\n\nPhysical or verbal misconduct may be grounds for removing employees from Medical Center property, or grounds for arrest by the VA Police. Employees may be banned from Medical Center property because of inappropriate or illegal behavior. The vendor shall not be entitled to any compensation from the Government for any costs resulting from employee misconduct (including, but not limited to, delays in contract completion) and may be held liable for costs incurred by the Government because of employee misconduct.\n\nTobacco Use is 100% prohibited on all VA property. \n\nThe VA will not be responsible for storage of equipment, materials, or tools.  \n\nIt is the vendor s responsibility to properly assess the working conditions and include in the bid any specialty equipment, training, additional time, personnel, or safety equipment to perform the work safely and in compliance with all applicable local, State, and Federal regulations. \n\nIf any damage is done to the property and building, by the vendor, the vendor is fully responsible for bearing the costs of repair and interim costs for maintaining medical center operations.\n\nHours of Work\n\nNormal working hours are 0700   1600 Monday to Friday, except for federal holidays.  Preparation can be done during these hours.  To reduce patient impact, all work that requires a utility outage will need to take place during afterhours (1700   0500) or during weekends.  All work started shall be completed and the work area(s) ready for full operations no later than 0500 the following day, unless otherwise coordinated with the COR.  All schedules and work hours shall be requested, coordinated, and approved through the COR.  \n\nSecurity\n\nNo badging is required for this requirement due to lack of need for vendor to be working onsite without VA supervision.\n\nSafety\n\nWhenever executing work within the proximity of live electrical equipment (including testing, voltage/current measurements, infrared scans, ultrasonic scans, and/or verifying a de-energized condition prior to performing work), the vendor shall provide and wear full and proper Personal Protective Equipment per the requirements of VHA Directive 1028, NFPA 70E.  The vendor must also provide all lockout/tagout equipment required to secure electrical safe work conditions.  \n\nReferences \n\nContractors shall have ready access to the latest versions of the following references: \n\nNFPA 70B, Recommended Practice for Electrical Equipment Maintenance\nNFPA 70E, Standard for Electrical Safety in the Workplace\nOSHA Standard 29 CFR 1910\n\n\nParking/Laydown Area\n\nThe vendor shall coordinate with the COR for parking at the facility. The vendor shall communicate the amount of space. At no time shall vehicles be parked on roadways, patient parking areas, the loading dock, etc.  \n\n\nPeriod of Performance\n\nPeriod of Performance is 365 calendar days.\n\nHospital operations shall take priority. Vendor shall do everything feasible to ensure the continuation of hospital operations.","origin":"detail"},"contacts":[{"name":"Scottie Scott","role":"primary","email":"scottie.scott@va.gov","phone":"(803) 776-4000","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"naics_codes":["561621"],"award":{"awardee":{}},"attachments":[{"resource_id":"a2551f2f6ce94b71a0222c3fff39f2dc","name":"36C24726Q0664.docx","kind":"file","mime_type":".docx","size_bytes":24177,"posted_at":"2026-07-02T16:55:43.331Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a2551f2f6ce94b71a0222c3fff39f2dc/download","mirrored":false}],"awards":[],"related":[{"key":"36C24727Q0118","latest_notice_id":"27bcc9cdef604254982ea444d657d39d","title":"6515--STERILIZATION CONTAINERS","solicitation_number":"36C24727Q0118","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339113","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24726R0134","latest_notice_id":"8f0c90b43099494cb8a8201cd475406f","title":"Y1DA | 521-24-102 | Renovate Wards 2K and 2B for Optometry/Ophthalmology Clinical Use","solicitation_number":"36C24726R0134","notice_type":"o","first_type":"p","first_posted":"2026-09-25","last_posted":"2026-11-18","notices":7,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"AL","county":"01073","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24727Q0067","latest_notice_id":"f75d8541b0604a57a55c64094b365d82","title":"J065--Building 3 Dental Vacuum Pump Replacement","solicitation_number":"36C24727Q0067","notice_type":"k","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":6,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"GA","county":"13175","county_name":"Laurens County","city":"1324376","city_name":"Dublin","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24727Q0115","latest_notice_id":"58ac14c8858846ce9a8d172472648821","title":"C1DA--544-27-110 | Update Facility Masterplan Architect and Engineering","solicitation_number":"36C24727Q0115","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"541330","psc":"C1DA","set_aside":"SDVOSBC","state":"SC","county":"45079","county_name":"Richland County","city":"4516000","city_name":"Columbia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"FA850127R0003","latest_notice_id":"7fd34decbcd445fcb695d7d1a483b635","title":"Delivery and Installation of Integrated Base Defense Security Systems (IBDSS) for buildings on Robins AFB","solicitation_number":"FA850127R0003","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-18T17:00:00Z","due_date":"2026-12-18","closes_at":"2026-12-18T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8501","office_name":"FA8501 OPL CONTRACTING AFSC/PZIO","naics":"561621","psc":"N063","set_aside":"SBA","state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Robins Air Force Base","site_key":"robins-air-force-base-ga","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"IHSSS11182026","latest_notice_id":"38800d0d6ad64cecabc18acf586542a5","title":"Fire Monitoring, Inspections, Maintenance, and Remediation Services","solicitation_number":"IHSSS11182026","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"561621","psc":"6350","set_aside":"ISBEE","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"3030127RFQ000001","latest_notice_id":"140cd38f6403477ebe7b5d43a5d18e61","title":"USCG Station Wachapreague Alarm Monitoring Service","solicitation_number":"3030127RFQ000001","notice_type":"o","first_type":"o","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"561621","psc":"S211","set_aside":"SBA","state":"VA","county":"51001","county_name":"Accomack County","city":"5182320","city_name":"Wachapreague","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-24T06:18:02.791414Z"}],"similar_open_total":27,"indexable":false}