{"canonical":"https://sealedbidder.com/opportunities/36c24726q0453","key":"36C24726Q0453","url":"https://sealedbidder.com/opportunities/36c24726q0453","title":"J061--Maintenance, Inspection, and Testing of the Electrical Power Distribution System","solicitation_number":"36C24726Q0453","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-14T13:00:00Z","first_posted":"2026-04-14","last_posted":"2026-04-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"221122","psc":"J061","set_aside":null,"place_state":"AL","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"01087","place_county_name":"Macon County","place_city":"0177304","place_city_name":"Tuskegee","winner":null,"award_amount":null,"publications":[{"notice_id":"4734ccde8f92401f8ebc6a8903a48539","title":"J061--Maintenance, Inspection, and Testing of the Electrical Power Distribution System","solicitation_number":"36C24726Q0453","notice_type":"r","base_type":"r","posted":"2026-04-14","posted_at":"2026-04-14T14:12:49.036Z","due_at":"2026-04-14T13:00:00Z","due_date":"2026-04-14","cancelled":false,"archived":true,"archive_date":"2026-05-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4734ccde8f92401f8ebc6a8903a48539/view","enriched":true,"history":[{"index":3,"title":"J061--Maintenance, Inspection, and Testing of the Electrical Power Distribution System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-14T14:12:49.036Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"4734ccde8f92401f8ebc6a8903a48539","solicitation_number":"36C24726Q0453"}]}],"latest_notice_id":"4734ccde8f92401f8ebc6a8903a48539","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-04-14","posted_at":"2026-04-14T14:12:49.036Z","created_at":"2026-04-14T14:12:46.734Z","modified_at":"2026-05-15T03:55:43.900Z","response_deadline":{"raw":"2026-04-14T09:00:00-04:00","utc":"2026-04-14T13:00:00Z","date":"2026-04-14","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4734ccde8f92401f8ebc6a8903a48539/view"},"naics":{"codes":["221122"],"primary":"221122"},"title":"J061--Maintenance, Inspection, and Testing of the Electrical Power Distribution System","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-14","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--Maintenance, Inspection, and Testing of the Electrical Power Distribution System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-14T14:12:49.036Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"4734ccde8f92401f8ebc6a8903a48539","solicitation_number":"36C24726Q0453"}],"contacts":[{"name":"Don Grier","role":"primary","email":"Don.Grier@va.gov","phone":"404-321-6111 x4926","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"4734ccde8f92401f8ebc6a8903a48539","lineage_id":"4734ccde8f92401f8ebc6a8903a48539","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-07T00:35:02.925989941Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"06656685f1e9e22dc8518f66cce4ab8589f8fb2e48bd3b66fd566406d14c640d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-07T00:35:02.925989941Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Maintenance, Inspection, and Testing of the Electrical Power Distribution System\n\nScope of Work:\nContractor shall provide equipment, supplies and labor for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all its components for the Montgomery and Tuskegee Campuses..\n\nPlace of Performance: \nCentral Alabama VA Medical Center   Tuskegee\n2400 Hospital Road\nTuskegee, AL 36083\n\nCentral Alabama VA Medical Center   Montgomery\n215 Perry Hill Road\nMontgomery, AL 36109\n\nBasic Requirements:\nMaintenance and Testing Requirements:\n\na. Service to provide electrical testing of medium voltage, and low voltage system panels, breakers, disconnects, and all other listed items. The electrical distribution system is located at the Central Alabama Veterans Health Center System (CAVHCS), 215 Perry Hill Road, Montgomery, AL 36109, and at the Tuskegee Campus at 2400 Hospital Road, Tuskegee, AL 36083. Work is to be performed after normal working hours. Shutdowns should be coordinated at least three weeks in advance. Upon contract award, a shutdown schedule should be provided detailing the areas to be shut down, the dates and durations of the shutdowns. \n\nb.  Supplies and services: Professional testing and maintenance of electrical systems and equipment. Provide all necessary labor, equipment, and supplies to conduct electrical analysis, including specialized testing, inspection, cleaning, adjustment, and appraisal of electrical distribution systems and apparatus to ensure their reliable operation. Testing shall adhere to manufacturer s recommendations and applicable NEMA, NEC, ANSI, ASTM, ASA, and VA standards outlined in VA Directive 1028. All work shall comply with VHA Directive 1028, Facility Electrical Power Systems, including the requirement that planned electrical system shutdowns are the standard method for maintenance and repair; energized work is permitted only when justified under NFPA 70E and OSHA, with a documented risk assessment and energized work permit approved in accordance with VHA Directive 1028\n\nScope: Professional testing and maintenance of the following electrical systems and equipment at the Montgomery Campus:\n\n- Switchgear equipment\n- Medium voltage circuit breakers\n-  Infrared panels\n- 13KV pad mount switches\n- 13 KV pad mount transformers\n- Protective relays primary disconnects\n- Transformers\n- Low voltage circuit breakers and generators\n- transfer switches\n- double-ended switchboards\n- generator switchboard\n- 13 KV double-ended switchboard with 1200 amp. breakers in an Automatic Transfer Scheme. The Automatic Transfer Scheme function testing shall be witnessed by an Engineer. \nInfrared scanning and any other energized inspections must follow NFPA 70E safe work practices (arc flash assessment, PPE, approach boundaries, and energized work permitting where applicable)\nEquipment\nMontgomery\nTuskegee\nGenerators\n4\n9\nTransformers\n10\n21\nProtective Relays\n10\n12\nLow Voltage Breakers\n50\n67\nMedium Voltage Breakers\n10\n120\nTransfer Switches (ATS)\n13\n20\n\nScope: Ground resistance testing of the entire facility s grounding system at both campuses. \n\nPeriod of Performance: \n  90 days from the Notice to Proceed.\n\nAll interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information.  THIS IS NOT A SOLICITATION ANNOUNCEMENT.  This is a Source s Sought synopsis only.  Questions should be submitted by email to Don.Grier@va.gov. Provide only the requested information below.  The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders, and/or large business) relative to NAICS 221122. \nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and UEI Number.\n2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing this type of service. \n3) Submit Capability Statements via email to don.grier@va.gov by April 20, 2026. Responses should be received no later than 9:00 AM EDT. \nNO CAPABILITY STATEMENTS MAY BE SUBMITTED AFTER APRIL 20, 2026.\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION).  A FUTURE NOTICE WILL BE POSTED WHEN THE SOLICITATION WILL BE RELEASED.\n\n4) Disclaimer and Important Notes:  This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n(5) No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).","text":"Maintenance, Inspection, and Testing of the Electrical Power Distribution System\n\nScope of Work:\nContractor shall provide equipment, supplies and labor for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all its components for the Montgomery and Tuskegee Campuses..\n\nPlace of Performance:\nCentral Alabama VA Medical Center Tuskegee\n2400 Hospital Road\nTuskegee, AL 36083\n\nCentral Alabama VA Medical Center Montgomery\n215 Perry Hill Road\nMontgomery, AL 36109\n\nBasic Requirements:\nMaintenance and Testing Requirements:\n\na. Service to provide electrical testing of medium voltage, and low voltage system panels, breakers, disconnects, and all other listed items. The electrical distribution system is located at the Central Alabama Veterans Health Center System (CAVHCS), 215 Perry Hill Road, Montgomery, AL 36109, and at the Tuskegee Campus at 2400 Hospital Road, Tuskegee, AL 36083. Work is to be performed after normal working hours. Shutdowns should be coordinated at least three weeks in advance. Upon contract award, a shutdown schedule should be provided detailing the areas to be shut down, the dates and durations of the shutdowns.\n\nb. Supplies and services: Professional testing and maintenance of electrical systems and equipment. Provide all necessary labor, equipment, and supplies to conduct electrical analysis, including specialized testing, inspection, cleaning, adjustment, and appraisal of electrical distribution systems and apparatus to ensure their reliable operation. Testing shall adhere to manufacturer s recommendations and applicable NEMA, NEC, ANSI, ASTM, ASA, and VA standards outlined in VA Directive 1028. All work shall comply with VHA Directive 1028, Facility Electrical Power Systems, including the requirement that planned electrical system shutdowns are the standard method for maintenance and repair; energized work is permitted only when justified under NFPA 70E and OSHA, with a documented risk assessment and energized work permit approved in accordance with VHA Directive 1028\n\nScope: Professional testing and maintenance of the following electrical systems and equipment at the Montgomery Campus:\n\n- Switchgear equipment\n- Medium voltage circuit breakers\n- Infrared panels\n- 13KV pad mount switches\n- 13 KV pad mount transformers\n- Protective relays primary disconnects\n- Transformers\n- Low voltage circuit breakers and generators\n- transfer switches\n- double-ended switchboards\n- generator switchboard\n- 13 KV double-ended switchboard with 1200 amp. breakers in an Automatic Transfer Scheme. The Automatic Transfer Scheme function testing shall be witnessed by an Engineer.\nInfrared scanning and any other energized inspections must follow NFPA 70E safe work practices (arc flash assessment, PPE, approach boundaries, and energized work permitting where applicable)\nEquipment\nMontgomery\nTuskegee\nGenerators\n4\n9\nTransformers\n10\n21\nProtective Relays\n10\n12\nLow Voltage Breakers\n50\n67\nMedium Voltage Breakers\n10\n120\nTransfer Switches (ATS)\n13\n20\n\nScope: Ground resistance testing of the entire facility s grounding system at both campuses.\n\nPeriod of Performance:\n90 days from the Notice to Proceed.\n\nAll interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a Source s Sought synopsis only. Questions should be submitted by email to Don.Grier@va.gov. Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders, and/or large business) relative to NAICS 221122.\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and UEI Number.\n2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing this type of service.\n3) Submit Capability Statements via email to don.grier@va.gov by April 20, 2026. Responses should be received no later than 9:00 AM EDT.\nNO CAPABILITY STATEMENTS MAY BE SUBMITTED AFTER APRIL 20, 2026.\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION). A FUTURE NOTICE WILL BE POSTED WHEN THE SOLICITATION WILL BE RELEASED.\n\n4) Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n(5) No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24726Q0453","place_of_performance":{"zip":"36083","city":{"name":"Tuskegee"},"state":{"name":"AL"},"street":"DEPARTMENT OF VETERANS AFFAIRS VETERANS HEALTH ADMINISTRATION","country":{"code":"USA","name":"UNITED STATES"},"street2":"Central Alabama VA Medical Center - Tuskegee 2400 Hospital Road"},"product_service_code":"J061"}],"due_at":"2026-04-14T13:00:00Z","due_date":"2026-04-14","closes_at":"2026-04-14T13:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","state":"AL","county":"01087","county_name":"Macon County","city":"0177304","city_name":"Tuskegee","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-07T01:07:54.444994Z","principal_notice_id":"4734ccde8f92401f8ebc6a8903a48539","description":{"text":"Maintenance, Inspection, and Testing of the Electrical Power Distribution System\n\nScope of Work:\nContractor shall provide equipment, supplies and labor for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all its components for the Montgomery and Tuskegee Campuses..\n\nPlace of Performance:\nCentral Alabama VA Medical Center Tuskegee\n2400 Hospital Road\nTuskegee, AL 36083\n\nCentral Alabama VA Medical Center Montgomery\n215 Perry Hill Road\nMontgomery, AL 36109\n\nBasic Requirements:\nMaintenance and Testing Requirements:\n\na. Service to provide electrical testing of medium voltage, and low voltage system panels, breakers, disconnects, and all other listed items. The electrical distribution system is located at the Central Alabama Veterans Health Center System (CAVHCS), 215 Perry Hill Road, Montgomery, AL 36109, and at the Tuskegee Campus at 2400 Hospital Road, Tuskegee, AL 36083. Work is to be performed after normal working hours. Shutdowns should be coordinated at least three weeks in advance. Upon contract award, a shutdown schedule should be provided detailing the areas to be shut down, the dates and durations of the shutdowns.\n\nb. Supplies and services: Professional testing and maintenance of electrical systems and equipment. Provide all necessary labor, equipment, and supplies to conduct electrical analysis, including specialized testing, inspection, cleaning, adjustment, and appraisal of electrical distribution systems and apparatus to ensure their reliable operation. Testing shall adhere to manufacturer s recommendations and applicable NEMA, NEC, ANSI, ASTM, ASA, and VA standards outlined in VA Directive 1028. All work shall comply with VHA Directive 1028, Facility Electrical Power Systems, including the requirement that planned electrical system shutdowns are the standard method for maintenance and repair; energized work is permitted only when justified under NFPA 70E and OSHA, with a documented risk assessment and energized work permit approved in accordance with VHA Directive 1028\n\nScope: Professional testing and maintenance of the following electrical systems and equipment at the Montgomery Campus:\n\n- Switchgear equipment\n- Medium voltage circuit breakers\n- Infrared panels\n- 13KV pad mount switches\n- 13 KV pad mount transformers\n- Protective relays primary disconnects\n- Transformers\n- Low voltage circuit breakers and generators\n- transfer switches\n- double-ended switchboards\n- generator switchboard\n- 13 KV double-ended switchboard with 1200 amp. breakers in an Automatic Transfer Scheme. The Automatic Transfer Scheme function testing shall be witnessed by an Engineer.\nInfrared scanning and any other energized inspections must follow NFPA 70E safe work practices (arc flash assessment, PPE, approach boundaries, and energized work permitting where applicable)\nEquipment\nMontgomery\nTuskegee\nGenerators\n4\n9\nTransformers\n10\n21\nProtective Relays\n10\n12\nLow Voltage Breakers\n50\n67\nMedium Voltage Breakers\n10\n120\nTransfer Switches (ATS)\n13\n20\n\nScope: Ground resistance testing of the entire facility s grounding system at both campuses.\n\nPeriod of Performance:\n90 days from the Notice to Proceed.\n\nAll interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a Source s Sought synopsis only. Questions should be submitted by email to Don.Grier@va.gov. Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders, and/or large business) relative to NAICS 221122.\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and UEI Number.\n2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing this type of service.\n3) Submit Capability Statements via email to don.grier@va.gov by April 20, 2026. Responses should be received no later than 9:00 AM EDT.\nNO CAPABILITY STATEMENTS MAY BE SUBMITTED AFTER APRIL 20, 2026.\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION). A FUTURE NOTICE WILL BE POSTED WHEN THE SOLICITATION WILL BE RELEASED.\n\n4) Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n(5) No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).","html":"Maintenance, Inspection, and Testing of the Electrical Power Distribution System\n\nScope of Work:\nContractor shall provide equipment, supplies and labor for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all its components for the Montgomery and Tuskegee Campuses..\n\nPlace of Performance: \nCentral Alabama VA Medical Center   Tuskegee\n2400 Hospital Road\nTuskegee, AL 36083\n\nCentral Alabama VA Medical Center   Montgomery\n215 Perry Hill Road\nMontgomery, AL 36109\n\nBasic Requirements:\nMaintenance and Testing Requirements:\n\na. Service to provide electrical testing of medium voltage, and low voltage system panels, breakers, disconnects, and all other listed items. The electrical distribution system is located at the Central Alabama Veterans Health Center System (CAVHCS), 215 Perry Hill Road, Montgomery, AL 36109, and at the Tuskegee Campus at 2400 Hospital Road, Tuskegee, AL 36083. Work is to be performed after normal working hours. Shutdowns should be coordinated at least three weeks in advance. Upon contract award, a shutdown schedule should be provided detailing the areas to be shut down, the dates and durations of the shutdowns. \n\nb.  Supplies and services: Professional testing and maintenance of electrical systems and equipment. Provide all necessary labor, equipment, and supplies to conduct electrical analysis, including specialized testing, inspection, cleaning, adjustment, and appraisal of electrical distribution systems and apparatus to ensure their reliable operation. Testing shall adhere to manufacturer s recommendations and applicable NEMA, NEC, ANSI, ASTM, ASA, and VA standards outlined in VA Directive 1028. All work shall comply with VHA Directive 1028, Facility Electrical Power Systems, including the requirement that planned electrical system shutdowns are the standard method for maintenance and repair; energized work is permitted only when justified under NFPA 70E and OSHA, with a documented risk assessment and energized work permit approved in accordance with VHA Directive 1028\n\nScope: Professional testing and maintenance of the following electrical systems and equipment at the Montgomery Campus:\n\n- Switchgear equipment\n- Medium voltage circuit breakers\n-  Infrared panels\n- 13KV pad mount switches\n- 13 KV pad mount transformers\n- Protective relays primary disconnects\n- Transformers\n- Low voltage circuit breakers and generators\n- transfer switches\n- double-ended switchboards\n- generator switchboard\n- 13 KV double-ended switchboard with 1200 amp. breakers in an Automatic Transfer Scheme. The Automatic Transfer Scheme function testing shall be witnessed by an Engineer. \nInfrared scanning and any other energized inspections must follow NFPA 70E safe work practices (arc flash assessment, PPE, approach boundaries, and energized work permitting where applicable)\nEquipment\nMontgomery\nTuskegee\nGenerators\n4\n9\nTransformers\n10\n21\nProtective Relays\n10\n12\nLow Voltage Breakers\n50\n67\nMedium Voltage Breakers\n10\n120\nTransfer Switches (ATS)\n13\n20\n\nScope: Ground resistance testing of the entire facility s grounding system at both campuses. \n\nPeriod of Performance: \n  90 days from the Notice to Proceed.\n\nAll interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information.  THIS IS NOT A SOLICITATION ANNOUNCEMENT.  This is a Source s Sought synopsis only.  Questions should be submitted by email to Don.Grier@va.gov. Provide only the requested information below.  The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders, and/or large business) relative to NAICS 221122. \nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and UEI Number.\n2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing this type of service. \n3) Submit Capability Statements via email to don.grier@va.gov by April 20, 2026. Responses should be received no later than 9:00 AM EDT. \nNO CAPABILITY STATEMENTS MAY BE SUBMITTED AFTER APRIL 20, 2026.\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION).  A FUTURE NOTICE WILL BE POSTED WHEN THE SOLICITATION WILL BE RELEASED.\n\n4) Disclaimer and Important Notes:  This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n(5) No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).","origin":"detail"},"contacts":[{"name":"Don Grier","role":"primary","email":"Don.Grier@va.gov","phone":"404-321-6111 x4926","title":"Contracting Officer"}],"place_of_performance":{"zip":"36083","city":{"name":"Tuskegee"},"state":{"name":"AL"},"street":"DEPARTMENT OF VETERANS AFFAIRS VETERANS HEALTH ADMINISTRATION","country":{"code":"USA","name":"UNITED STATES"},"street2":"Central Alabama VA Medical Center - Tuskegee 2400 Hospital Road"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"naics_codes":["221122"],"award":{"awardee":{}},"attachments":[{"resource_id":"2d9a028abf8248a7b8f362f0b0b8ea20","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-04-14T14:12:49.036Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/central-alabama-health-care/","mirrored":false}],"awards":[],"related":[{"key":"36C24726R0134","latest_notice_id":"8f0c90b43099494cb8a8201cd475406f","title":"Y1DA | 521-24-102 | Renovate Wards 2K and 2B for Optometry/Ophthalmology Clinical Use","solicitation_number":"36C24726R0134","notice_type":"o","first_type":"p","first_posted":"2026-09-25","last_posted":"2026-11-18","notices":7,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"AL","county":"01073","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24727Q0067","latest_notice_id":"f75d8541b0604a57a55c64094b365d82","title":"J065--Building 3 Dental Vacuum Pump Replacement","solicitation_number":"36C24727Q0067","notice_type":"k","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":6,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"GA","county":"13175","county_name":"Laurens County","city":"1324376","city_name":"Dublin","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24727Q0115","latest_notice_id":"58ac14c8858846ce9a8d172472648821","title":"C1DA--544-27-110 | Update Facility Masterplan Architect and Engineering","solicitation_number":"36C24727Q0115","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"541330","psc":"C1DA","set_aside":"SDVOSBC","state":"SC","county":"45079","county_name":"Richland County","city":"4516000","city_name":"Columbia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24726R0131","latest_notice_id":"4717bddf82034895b20f8a6b55d3068e","title":"Augusta 5 Year Wheelchair Service IDIQ","solicitation_number":"36C24726R0131","notice_type":"p","first_type":"o","first_posted":"2026-11-03","last_posted":"2026-11-03","notices":2,"due_at":"2026-12-01T13:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"485991","psc":"V212","set_aside":"SDVOSBC","state":"GA","county":"13245","county_name":"Richmond County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-04T05:14:00.353426Z"}],"similar_open":[],"similar_open_total":0,"indexable":false}