{"canonical":"https://sealedbidder.com/opportunities/36c24725r0069","key":"36C24725R0069","url":"https://sealedbidder.com/opportunities/36c24725r0069","title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","solicitation_number":"36C24725R0069","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-30T16:00:00Z","first_posted":"2025-01-29","last_posted":"2025-09-22","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"541330","psc":"C1DA","set_aside":"SDVOSBC","place_state":"SC","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"45079","place_county_name":"Richland County","place_city":"4516000","place_city_name":"Columbia","winner":"KSM A&E FEDERAL GROUP, LLC","award_amount":"836735.25","publications":[{"notice_id":"11ec140441c94ea4b8f02bb4204404c9","title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","solicitation_number":"36C24725R0069","notice_type":"p","base_type":"p","posted":"2025-01-29","posted_at":"2025-01-29T17:15:59.114Z","due_at":"2025-02-28T17:00:00Z","due_date":"2025-02-28","cancelled":false,"archived":true,"archive_date":"2025-03-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/11ec140441c94ea4b8f02bb4204404c9/view","enriched":true,"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}]},{"notice_id":"4cfecf8490094102923cbe6074d79aa5","title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","solicitation_number":"36C24725R0069","notice_type":"p","base_type":"p","posted":"2025-07-22","posted_at":"2025-07-22T19:39:59.297Z","due_at":"2025-07-29T16:00:00Z","due_date":"2025-07-29","cancelled":false,"archived":true,"archive_date":"2025-07-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4cfecf8490094102923cbe6074d79aa5/view","enriched":true,"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}]},{"notice_id":"162032ef6893413f9605637fadc972f7","title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","solicitation_number":"36C24725R0069","notice_type":"p","base_type":"p","posted":"2025-07-23","posted_at":"2025-07-23T18:18:37.894Z","due_at":"2025-07-30T16:00:00Z","due_date":"2025-07-30","cancelled":false,"archived":true,"archive_date":"2025-08-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/162032ef6893413f9605637fadc972f7/view","enriched":true,"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}]},{"notice_id":"8db96d77a7a84d79aeb44e97d5bfa352","title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","solicitation_number":"36C24725R0069","notice_type":"a","base_type":"a","posted":"2025-09-22","posted_at":"2025-09-22T19:53:09.438Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-09-29","removed_at":null,"award_number":"36C24725C0110","awardee_name":"KSM A&E FEDERAL GROUP, LLC","amount":"836735.25","link_sam":"https://sam.gov/workspace/contract/opp/8db96d77a7a84d79aeb44e97d5bfa352/view","enriched":true,"history":[{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T19:53:09.438Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8db96d77a7a84d79aeb44e97d5bfa352","solicitation_number":"36C24725R0069"}]}],"latest_notice_id":"8db96d77a7a84d79aeb44e97d5bfa352","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-29","posted_at":"2025-01-29T17:15:59.114Z","created_at":"2025-01-29T17:15:56.942Z","modified_at":"2025-08-07T03:55:46.543Z","response_deadline":{"raw":"2025-02-28T12:00:00-05:00","utc":"2025-02-28T17:00:00Z","date":"2025-02-28","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/11ec140441c94ea4b8f02bb4204404c9/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-07","archive_type":"auto_custom"},"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}],"contacts":[{"name":"Christopher Nash Jenkins","role":"primary","email":"christopher.jenkins@va.gov","phone":"478-595-2794","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"11ec140441c94ea4b8f02bb4204404c9","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"11ec140441c94ea4b8f02bb4204404c9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T03:18:58.670008043Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"7ea9d50b96e897275202a551beaad2d2ed04bc158432dcca365e2a1d4fb885e3","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T03:18:58.670008043Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS PRE-SOLICITATION NOTICE IS NOT A REQUEST FOR PROPOSAL. ALL\nINFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED\nHEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL\nINFORMATION WILL BE ISSUED.\n\nProject: 544-23-108 Cast Iron Fittings and Valves Steam Distribution Systems Study\n\nWork Location: Wm. Jennings Bryan Dorn VA Medical Center, Columbia, SC 29209\n\nEstimated/Target Completion Period: 180 Calendar days after Award.\n\nNAICS: 541330 - Engineering Services\n\nSmall Business Standard: $25.5 million\n\nSet-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\n\nSite Visits will not be arranged during this phase.\n\nThe anticipated award date of the proposed A-E Contract is on or before September\n30, 2025.\n\nSF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than\n(NLT) 12:00 PM (EST) February 28, 2025.\n\n***ATTENTION*** Acknowledgement e-mails will be sent from the CO upon receipt of a submission. If an acknowledgement is not returned, the firm should contact the CO at christopher.jenkins@va.gov and 478-595-2794.\n\nPROJECT OVERVIEW:\nThe Columbia VA Health Care System requires a full campus-wide steam distribution survey to accomplished design alert number 003C2B-DA-151, Cast Iron Fittings/Valve Housings, Prohibition of Use in High and Medium Pressure Steam Distribution Systems, 12-15-2021 in addition to Memorandum dated December 13, 2024 related to ASTM A307 fasteners for Steam and hot water heating systems.  Identify the locations of all cast iron, ductile, or malleable fittings, valve housings, piping, and components along with all ASTM A307 fasteners in high pressure and medium pressure steam systems.  This requirement covers systems operating at a pressure of 15 Pounds per Square Inch Gauge (PSIG) or greater and hot water distribution systems for hot water or other liquids at a temperature of greater than 257 degrees Fahrenheit.\n\nSDVOSB SET-ASIDE:\n\nThis requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in SBA VetCert: https://veterans.certify.sba.gov/ prior to submission of proposal and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligibility determination is performed by the Center for Veterans Enterprise (CVE). Eligible SDVOSB concerns must also be registered at the following websites:\n\nSystem for Award Management (SAM): https://www.sam.gov\n\nVETS-4212 Federal Contractor Reporting https://www.dol.gov/agencies/vets/programs/vets4212\n\nImportant Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Department of Veteran Affairs Center for Veterans Enterprise (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so.\n\nFor a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) SBA VetCert: https://veterans.certify.sba.gov/ and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to\ncontract award.\n\nIn order to assure compliance with FAR Clauses, 52.219-14 Limitations on\nSubcontracting (DEVIATION 2019-01) and VAAR 852.219-10, VA Notice of Total\nService-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019)\n(DEVIATION), all firms submitting a SF 330 for this pre-solicitation notice are\nrequired to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as nonresponsive and preclude further evaluation.\n\nFAR Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in FAR 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of Georgia.\n\n\nSELECTION CRITERIA   \n\nSF330s shall be organized in the following order:  \n\nCover Sheet (one-page limit)\nDesign team background with locations of supporting offices (one-page limit)\nDesign team organizational structure with key discipline roles (one-page limit)\nFactor 1   Specialized Experience (one page per project limit) \nFactor 2 - Professional Qualifications (one page per resume limit)\nFactor 3   Past Performance Summary Sheet (one-page limit)\nFactor 4 - Capacity (one-page limit)\nFactor 5   Knowledge or Location (one-page limit)\nFactor 6   SDVOSB Inclusion Statement (one-page limit)\nFull CPARS/PPQs Documentation for Factor 1 Projects (20-page limit) \nAdditional Information (10-page limit)\n\nSF330s received out of sequence will be viewed negatively. \n\nSF330 Specific Requirements:\nAll SF330 pages shall be in PDF searchable for items 1 through 9 and item 11.  Full CPARS and PPQs may be scanned. \nStart each factor response on a new page.\nUse no less than 11-point font.\nAll text and images containing text is legible when printed on 8.5  x 11  paper. The evaluation board will not seek clarification regarding illegible text. \n  \n\nPrimary Selection Criteria (listed in descending order of importance):\n\nFactor 1\nSpecialized Experience (Sections F, G and H): Specialized experience and technical competence in the design and construction period services will be required to perform throughout the life of the contract. Projects experience pertains to the types, size, recency, cost, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation.  \n\nPage Limit   One page per project.  Five-page total for Factor 1.  Information provided on additional pages beyond the one page per project limit or beyond the five-page total limit will not be included with the review. \nRelevant Project Experience: Submit five (5) projects that meet all criteria shown below. \n\nRelevant Project Type   Projects that site investigation and documenting steam line infrastructure conditions and generating P&ID drawings. \nRelevant Project Size   Projects that include Main boiler plants, site distribution infrastructure, and mechanical rooms. \nRelevant Project Recency   Project must be complete or substantially complete within the past five years of the solicitation due date.  Substantially complete is defined as 80% or greater of the project is complete at the time of the solicitation due date.  \nRelevant Project Cost - Construction project cost must be greater than $100,000.00.\nRelevant Project Complexity   The project narrative description must indicate experience with all the following criteria:\nOnsite investigation, reverification, and recording of steam infrastructure system. \nNon-Destructive Investigation and Restoration\nConfined Space Program Implementation\nAnalysis Studies of Steam Infrastructure Systems\n\nThe relevant project criteria listed above is the minimal information required for acceptable project relevance.  Additional value will be considered for projects which convey expertise with the following categories and will potentially increase the overall rating for this factor.  Projects that do not convey additional value expertise will not be considered a weakness. Additional value expertise includes: \n\nExperience with the submitting firm serving as the prime contractor.\nVA relevant project experience.  \nSubmissions shall include no more and no less than five (5) type projects of recent and relevant Government and private experience projects similar in type, size, recency, and complexity, cost, and experience with the type of projects/competence above.\nSection G will used to evaluate the prior experience of the prime firm and any key subcontractors working together as a cohesive unit on the provided relevant projects.  An acceptable rating will be given if all key disciplines are shown, and each discipline participated with at least one project listed on section G. Proposed design team members that do not have experience with any of the five submitted example projects as shown in section G will be viewed negatively.  \n\nFactor 2\nProfessional Qualifications (Sections C through E) necessary for satisfactory performance of required service.  The AE shall demonstrate they are able to sign and stamp each drawing by individuals licensed in any state in the United States for the key positions listed below.  The design firm and A-E staff representing the project must be licensed to practice in any state of the United States of America. Provide Professional License numbers and/or proof of Licensure. The evaluation shall consider the specific experience (minimum of five years) and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full-time employees) of personnel proposed for assignment to the project, and their record of working together as a team when evaluating professional qualifications. The lead designer in each discipline must be registered to sign drawings in each discipline must but does not have to be registered in the state where the project is located. The licensed professional must hold current licensure for said discipline to practice in any state of the United States of America.  Engineer-in -training (EIT) is not considered a professional licensure. \nPage Limit   One page limit per position resume.  Four pages total for Factor 2.  Information provided on additional pages beyond the four-page limit will not be included with the review. \nResume Requirements - A resume for each of these key positions MUST be provided identifying their specific role, via Section E in the SF330. Key positions and disciplines required for this project include, but are not limited to, the lists of professionals with required licensure and preferred licensure below.  An unacceptable rating may be given if resumes are not provided for all roles listed.  \nPositions requiring professional licensure. Not providing the professional licensure will be viewed negatively and will not be compliant with the solicitation. \nMechanical Engineer - PE\n\nKey positions with preferred qualifications. Design team professionals that have obtained the indicated preferred qualifications may be viewed more favorably. Not providing the preferred qualifications will not be viewed negatively and will not reduce the overall rating for this factor.  Higher value may be given for professionals with the preferred qualifications. \n\nQuality Control Manager - Either CQM, CQE, Lean Six Sigma Black Belt, or experience with minimum five projects were served as QC Manager.\nProject Manager - Project Management Professional (PMP) certification or 10 years managing government A/E contracts. \nConstruction Cost Estimator - ASPE Certified Professional Estimator (CPE) Certification\n\nMulti-function roles are allowable for the following positions and may be shown as multi-role positions on the resumes:\nProject Manager and Quality Control Manager\n\nInclude the home office location for each key discipline identified on each respective resume in Section E block 15. \n\nThe criteria listed above is the minimal information required for acceptable professional qualifications.  Additional value will be considered for each key position and will potentially increase the overall rating for this factor and shall not exceed the prescribed page limit.\nFirms holding certification from The American Society of Mechanical Engineers (ASME) for the assembly of pressure piping in accordance with the applicable rules of the ASME Boiler and Pressure Vessel Code (BPVC).  \nKey personnel having greater than 10 years  experience in the practicing field.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \nFactor 3\nPast performance (section H): Past performance will be evaluated on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules along with the firm s history of design error, omission, and/or deficiency claims.  \nPast performance will be evaluated for all projects provided in Section F. The Contractor Performance Assessment Rating System (CPARS) database will be reviewed to evaluate the projects that have a VA CPARS entry. VA CPARS are not required to be submitted with the SF330 submission. However, if the VA CPARS is not included with the SF330 submission, then the contract number for the project must be submitted for each project provided in Section F so CPARS can be reviewed in the database.  Please note we are unable to review any CPARS from other Federal Agencies, outside of the VA.\n\nFor any project that does NOT have VA CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. If the firm (Prime or Subcontractor) was not the Prime Contractor on any project submit-ted in the SF330 a PPQ must be provided listing their specific role as a subcontractor. The PPQ should be rated and signed by the evaluator. In the event that a firm does not receive a requested complete PPQ from an evaluator prior to the time for submission, the firm shall submit the partially completed PPQ with Section 1 and the Evaluator Information in Section 2 completed. Ensure a POC is listed with the project title/contract number. The VA will make reasonable attempts to contact the POC upon submission for PPQ completion.\n\nThe Government may also consider additional performance related information regarding the firm, to include customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. The Government reserves the right to contact any POC listed on a CPARS report or PPQ. If appropriate, the record of significant claims against the firm because of improper or incomplete architectural and engineering services may be evaluated.\n\nFailure to provide requested data, accessible points of contact, or valid phone numbers will result in a firm being considered less qualified. The information for this factor shall be provided in Section H of the SF 330. \n\nFor PPQs, please utilize the attached PPQ document. Completed PPQs should be incorporated into the SF 330 directly. PPQs should not be submitted to the VHA PCAC directly. Any CPARS and PPQs will not be counted towards the page limitations for this submission. However, any narratives provided for past performance in Section H will be counted toward the page limit. \n\nPage Limit   Provide no more than one page total for this factor for the summary page.  Full CPARS/PPQ documentation shall be included on additional pages with the SF330 and shall not exceed 20 pages.  \nProvide a summary page that provides the factor s required information. For each of the five projects, provide the following information. \nProject Information (each project for Specialized Experience)\nPast Performance Record Type (PPQ or CPARS)\nContract Number\nPoint of Contact (Name, Phone, Email, Job Title, POC Role)\nAE Firm Role with Project (Prime or Subcontractor)\nCategory Ratings\n\nProvide complete CPARS (or PPQs if CPARS is not available) for all sample projects after the SF330 Factor 8 section. \n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor.  Locate this documentation after the complete CPARS/PPQ documents.  Additional value documentation shall not exceed five pages.\nLetters of appreciation or accolades from previous projects\nIndustry recognition or design awards\nAny other information the design team wishes to include for this factor so long as the five-page limit is not exceeded. \nFactor 4\nCapacity (section H): The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of key disciplines to perform the work in the required time. Provide the available capacity of key disciplines by providing current project workload, inclusive of all projects awarded by the VA, any Federal Agency, and Private Sector during the previous twelve (12) months and the full potential value of projects forecasted within the next twenty-four (24) months any current indefinite delivery contracts that the firm has.  Include the full potential value of any current indefinite delivery contracts. Offeror shall clearly state their available capacity presenting workload percentages for the key disciplines and/or team members, including sub-consultants. Also, the offeror must provide the completion percentages and expected completion date for all the VA projects current and forecasted. awarded in the previous 12 months. Please ensure the capacity applies toward the team/personnel provided in the SF330.  The information for this factor shall be provided in Section H of the SF330. \nPage Limit   Provide no more than two pages total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review. \nInclude a table that conveys each key discipline, quantity of current design project workload, quantity of current construction period service workload, estimated future design load, estimated future construction workload, quantity of current IDIQ contracts, total IDIQ contract capacity, total remaining IDIQ capacity, and percent the key discipline is available. For example:\n\nKey Discipline\nTotal # of Current Design Project Workload\n# of Current Construction Project Workload\nEstimated # of Future Design Project Workload\nEstimated # of Future Construction Project Workload\nQuantity of current IDIQ contracts involved with\nTotal IDIQ capacity all contracts\n(millions)\nTotal IDIQ remaining capacity\n(millions)\nPercent Available\nCapacity\nArchitect\n6\n7\n6\n7\n4\n$6M\n$2M\n45%\nMechanical Engineer\n4\n8\n3\n8\n2\n$3M\n$1\n10%\nAdd Disciplines as Required\n\n\n\n\n\n\n\n\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Do not include additional pages in the additional information section.\nProviding a narrative conveying the design team s approach on how new work will merge with the current workload. \nProvide a narrative describing the process regarding replacement of key disciplines should one decide to leave the design team.  \nConvey how the design team can maintain schedule if a key discipline member is no longer available?\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \nFactor 5\nKnowledge of Locality (Section H). Knowledge of the locality, to include specific knowledge of certain local conditions or project site features.  The information for this factor shall be provided in Section H of the SF 330. \n\nNote that the intent of this factor is to showcase a firm s understanding of the site and locality, and NOT where the firm is located, how far away the firm/branch office is from the site, and how they would travel to the site.\n\nPage Limit   Page Limit   Provide no more than one page total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review. \nProvide an individual narrative conveying knowledge of the locality for each of the following categories:\nLocal conditions or project site features\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section. \nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \n\nFactor 6\nUse of Service- Disabled Veteran-Owned Small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors.  Offerors shall be evaluated based on their utilization plans for service- disabled Veteran- owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation.\n\nPage Limit   Page Limit   Provide no more than one page total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide a listing of all consulting firms and business government certification(s).  Indicate the anticipated percentage of work the consulting firm will perform.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  The higher percentage of certified SDVOSB firms included with the design team may provide additional value and potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.","text":"THIS PRE-SOLICITATION NOTICE IS NOT A REQUEST FOR PROPOSAL. ALL\nINFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED\nHEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL\nINFORMATION WILL BE ISSUED.\n\nProject: 544-23-108 Cast Iron Fittings and Valves Steam Distribution Systems Study\n\nWork Location: Wm. Jennings Bryan Dorn VA Medical Center, Columbia, SC 29209\n\nEstimated/Target Completion Period: 180 Calendar days after Award.\n\nNAICS: 541330 - Engineering Services\n\nSmall Business Standard: $25.5 million\n\nSet-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\n\nSite Visits will not be arranged during this phase.\n\nThe anticipated award date of the proposed A-E Contract is on or before September\n30, 2025.\n\nSF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than\n(NLT) 12:00 PM (EST) February 28, 2025.\n\n***ATTENTION*** Acknowledgement e-mails will be sent from the CO upon receipt of a submission. If an acknowledgement is not returned, the firm should contact the CO at christopher.jenkins@va.gov and 478-595-2794.\n\nPROJECT OVERVIEW:\nThe Columbia VA Health Care System requires a full campus-wide steam distribution survey to accomplished design alert number 003C2B-DA-151, Cast Iron Fittings/Valve Housings, Prohibition of Use in High and Medium Pressure Steam Distribution Systems, 12-15-2021 in addition to Memorandum dated December 13, 2024 related to ASTM A307 fasteners for Steam and hot water heating systems. Identify the locations of all cast iron, ductile, or malleable fittings, valve housings, piping, and components along with all ASTM A307 fasteners in high pressure and medium pressure steam systems. This requirement covers systems operating at a pressure of 15 Pounds per Square Inch Gauge (PSIG) or greater and hot water distribution systems for hot water or other liquids at a temperature of greater than 257 degrees Fahrenheit.\n\nSDVOSB SET-ASIDE:\n\nThis requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in SBA VetCert: https://veterans.certify.sba.gov/ prior to submission of proposal and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligibility determination is performed by the Center for Veterans Enterprise (CVE). Eligible SDVOSB concerns must also be registered at the following websites:\n\nSystem for Award Management (SAM): https://www.sam.gov\n\nVETS-4212 Federal Contractor Reporting https://www.dol.gov/agencies/vets/programs/vets4212\n\nImportant Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Department of Veteran Affairs Center for Veterans Enterprise (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so.\n\nFor a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) SBA VetCert: https://veterans.certify.sba.gov/ and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to\ncontract award.\n\nIn order to assure compliance with FAR Clauses, 52.219-14 Limitations on\nSubcontracting (DEVIATION 2019-01) and VAAR 852.219-10, VA Notice of Total\nService-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019)\n(DEVIATION), all firms submitting a SF 330 for this pre-solicitation notice are\nrequired to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as nonresponsive and preclude further evaluation.\n\nFAR Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in FAR 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of Georgia.\n\nSELECTION CRITERIA\n\nSF330s shall be organized in the following order:\n\nCover Sheet (one-page limit)\nDesign team background with locations of supporting offices (one-page limit)\nDesign team organizational structure with key discipline roles (one-page limit)\nFactor 1 Specialized Experience (one page per project limit)\nFactor 2 - Professional Qualifications (one page per resume limit)\nFactor 3 Past Performance Summary Sheet (one-page limit)\nFactor 4 - Capacity (one-page limit)\nFactor 5 Knowledge or Location (one-page limit)\nFactor 6 SDVOSB Inclusion Statement (one-page limit)\nFull CPARS/PPQs Documentation for Factor 1 Projects (20-page limit)\nAdditional Information (10-page limit)\n\nSF330s received out of sequence will be viewed negatively.\n\nSF330 Specific Requirements:\nAll SF330 pages shall be in PDF searchable for items 1 through 9 and item 11. Full CPARS and PPQs may be scanned.\nStart each factor response on a new page.\nUse no less than 11-point font.\nAll text and images containing text is legible when printed on 8.5 x 11 paper. The evaluation board will not seek clarification regarding illegible text.\n\nPrimary Selection Criteria (listed in descending order of importance):\n\nFactor 1\nSpecialized Experience (Sections F, G and H): Specialized experience and technical competence in the design and construction period services will be required to perform throughout the life of the contract. Projects experience pertains to the types, size, recency, cost, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation.\n\nPage Limit One page per project. Five-page total for Factor 1. Information provided on additional pages beyond the one page per project limit or beyond the five-page total limit will not be included with the review.\nRelevant Project Experience: Submit five (5) projects that meet all criteria shown below.\n\nRelevant Project Type Projects that site investigation and documenting steam line infrastructure conditions and generating P&ID drawings.\nRelevant Project Size Projects that include Main boiler plants, site distribution infrastructure, and mechanical rooms.\nRelevant Project Recency Project must be complete or substantially complete within the past five years of the solicitation due date. Substantially complete is defined as 80% or greater of the project is complete at the time of the solicitation due date.\nRelevant Project Cost - Construction project cost must be greater than $100,000.00.\nRelevant Project Complexity The project narrative description must indicate experience with all the following criteria:\nOnsite investigation, reverification, and recording of steam infrastructure system.\nNon-Destructive Investigation and Restoration\nConfined Space Program Implementation\nAnalysis Studies of Steam Infrastructure Systems\n\nThe relevant project criteria listed above is the minimal information required for acceptable project relevance. Additional value will be considered for projects which convey expertise with the following categories and will potentially increase the overall rating for this factor. Projects that do not convey additional value expertise will not be considered a weakness. Additional value expertise includes:\n\nExperience with the submitting firm serving as the prime contractor.\nVA relevant project experience.\nSubmissions shall include no more and no less than five (5) type projects of recent and relevant Government and private experience projects similar in type, size, recency, and complexity, cost, and experience with the type of projects/competence above.\nSection G will used to evaluate the prior experience of the prime firm and any key subcontractors working together as a cohesive unit on the provided relevant projects. An acceptable rating will be given if all key disciplines are shown, and each discipline participated with at least one project listed on section G. Proposed design team members that do not have experience with any of the five submitted example projects as shown in section G will be viewed negatively.\n\nFactor 2\nProfessional Qualifications (Sections C through E) necessary for satisfactory performance of required service. The AE shall demonstrate they are able to sign and stamp each drawing by individuals licensed in any state in the United States for the key positions listed below. The design firm and A-E staff representing the project must be licensed to practice in any state of the United States of America. Provide Professional License numbers and/or proof of Licensure. The evaluation shall consider the specific experience (minimum of five years) and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full-time employees) of personnel proposed for assignment to the project, and their record of working together as a team when evaluating professional qualifications. The lead designer in each discipline must be registered to sign drawings in each discipline must but does not have to be registered in the state where the project is located. The licensed professional must hold current licensure for said discipline to practice in any state of the United States of America. Engineer-in -training (EIT) is not considered a professional licensure.\nPage Limit One page limit per position resume. Four pages total for Factor 2. Information provided on additional pages beyond the four-page limit will not be included with the review.\nResume Requirements - A resume for each of these key positions MUST be provided identifying their specific role, via Section E in the SF330. Key positions and disciplines required for this project include, but are not limited to, the lists of professionals with required licensure and preferred licensure below. An unacceptable rating may be given if resumes are not provided for all roles listed.\nPositions requiring professional licensure. Not providing the professional licensure will be viewed negatively and will not be compliant with the solicitation.\nMechanical Engineer - PE\n\nKey positions with preferred qualifications. Design team professionals that have obtained the indicated preferred qualifications may be viewed more favorably. Not providing the preferred qualifications will not be viewed negatively and will not reduce the overall rating for this factor. Higher value may be given for professionals with the preferred qualifications.\n\nQuality Control Manager - Either CQM, CQE, Lean Six Sigma Black Belt, or experience with minimum five projects were served as QC Manager.\nProject Manager - Project Management Professional (PMP) certification or 10 years managing government A/E contracts.\nConstruction Cost Estimator - ASPE Certified Professional Estimator (CPE) Certification\n\nMulti-function roles are allowable for the following positions and may be shown as multi-role positions on the resumes:\nProject Manager and Quality Control Manager\n\nInclude the home office location for each key discipline identified on each respective resume in Section E block 15.\n\nThe criteria listed above is the minimal information required for acceptable professional qualifications. Additional value will be considered for each key position and will potentially increase the overall rating for this factor and shall not exceed the prescribed page limit.\nFirms holding certification from The American Society of Mechanical Engineers (ASME) for the assembly of pressure piping in accordance with the applicable rules of the ASME Boiler and Pressure Vessel Code (BPVC).\nKey personnel having greater than 10 years experience in the practicing field.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\nFactor 3\nPast performance (section H): Past performance will be evaluated on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules along with the firm s history of design error, omission, and/or deficiency claims.\nPast performance will be evaluated for all projects provided in Section F. The Contractor Performance Assessment Rating System (CPARS) database will be reviewed to evaluate the projects that have a VA CPARS entry. VA CPARS are not required to be submitted with the SF330 submission. However, if the VA CPARS is not included with the SF330 submission, then the contract number for the project must be submitted for each project provided in Section F so CPARS can be reviewed in the database. Please note we are unable to review any CPARS from other Federal Agencies, outside of the VA.\n\nFor any project that does NOT have VA CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. If the firm (Prime or Subcontractor) was not the Prime Contractor on any project submit-ted in the SF330 a PPQ must be provided listing their specific role as a subcontractor. The PPQ should be rated and signed by the evaluator. In the event that a firm does not receive a requested complete PPQ from an evaluator prior to the time for submission, the firm shall submit the partially completed PPQ with Section 1 and the Evaluator Information in Section 2 completed. Ensure a POC is listed with the project title/contract number. The VA will make reasonable attempts to contact the POC upon submission for PPQ completion.\n\nThe Government may also consider additional performance related information regarding the firm, to include customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. The Government reserves the right to contact any POC listed on a CPARS report or PPQ. If appropriate, the record of significant claims against the firm because of improper or incomplete architectural and engineering services may be evaluated.\n\nFailure to provide requested data, accessible points of contact, or valid phone numbers will result in a firm being considered less qualified. The information for this factor shall be provided in Section H of the SF 330.\n\nFor PPQs, please utilize the attached PPQ document. Completed PPQs should be incorporated into the SF 330 directly. PPQs should not be submitted to the VHA PCAC directly. Any CPARS and PPQs will not be counted towards the page limitations for this submission. However, any narratives provided for past performance in Section H will be counted toward the page limit.\n\nPage Limit Provide no more than one page total for this factor for the summary page. Full CPARS/PPQ documentation shall be included on additional pages with the SF330 and shall not exceed 20 pages.\nProvide a summary page that provides the factor s required information. For each of the five projects, provide the following information.\nProject Information (each project for Specialized Experience)\nPast Performance Record Type (PPQ or CPARS)\nContract Number\nPoint of Contact (Name, Phone, Email, Job Title, POC Role)\nAE Firm Role with Project (Prime or Subcontractor)\nCategory Ratings\n\nProvide complete CPARS (or PPQs if CPARS is not available) for all sample projects after the SF330 Factor 8 section.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Locate this documentation after the complete CPARS/PPQ documents. Additional value documentation shall not exceed five pages.\nLetters of appreciation or accolades from previous projects\nIndustry recognition or design awards\nAny other information the design team wishes to include for this factor so long as the five-page limit is not exceeded.\nFactor 4\nCapacity (section H): The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of key disciplines to perform the work in the required time. Provide the available capacity of key disciplines by providing current project workload, inclusive of all projects awarded by the VA, any Federal Agency, and Private Sector during the previous twelve (12) months and the full potential value of projects forecasted within the next twenty-four (24) months any current indefinite delivery contracts that the firm has. Include the full potential value of any current indefinite delivery contracts. Offeror shall clearly state their available capacity presenting workload percentages for the key disciplines and/or team members, including sub-consultants. Also, the offeror must provide the completion percentages and expected completion date for all the VA projects current and forecasted. awarded in the previous 12 months. Please ensure the capacity applies toward the team/personnel provided in the SF330. The information for this factor shall be provided in Section H of the SF330.\nPage Limit Provide no more than two pages total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nInclude a table that conveys each key discipline, quantity of current design project workload, quantity of current construction period service workload, estimated future design load, estimated future construction workload, quantity of current IDIQ contracts, total IDIQ contract capacity, total remaining IDIQ capacity, and percent the key discipline is available. For example:\n\nKey Discipline\nTotal # of Current Design Project Workload\n# of Current Construction Project Workload\nEstimated # of Future Design Project Workload\nEstimated # of Future Construction Project Workload\nQuantity of current IDIQ contracts involved with\nTotal IDIQ capacity all contracts\n(millions)\nTotal IDIQ remaining capacity\n(millions)\nPercent Available\nCapacity\nArchitect\n6\n7\n6\n7\n4\n$6M\n$2M\n45%\nMechanical Engineer\n4\n8\n3\n8\n2\n$3M\n$1\n10%\nAdd Disciplines as Required\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Do not include additional pages in the additional information section.\nProviding a narrative conveying the design team s approach on how new work will merge with the current workload.\nProvide a narrative describing the process regarding replacement of key disciplines should one decide to leave the design team.\nConvey how the design team can maintain schedule if a key discipline member is no longer available?\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\nFactor 5\nKnowledge of Locality (Section H). Knowledge of the locality, to include specific knowledge of certain local conditions or project site features. The information for this factor shall be provided in Section H of the SF 330.\n\nNote that the intent of this factor is to showcase a firm s understanding of the site and locality, and NOT where the firm is located, how far away the firm/branch office is from the site, and how they would travel to the site.\n\nPage Limit Page Limit Provide no more than one page total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide an individual narrative conveying knowledge of the locality for each of the following categories:\nLocal conditions or project site features\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\n\nFactor 6\nUse of Service- Disabled Veteran-Owned Small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Offerors shall be evaluated based on their utilization plans for service- disabled Veteran- owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation.\n\nPage Limit Page Limit Provide no more than one page total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide a listing of all consulting firms and business government certification(s). Indicate the anticipated percentage of work the consulting firm will perform.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. The higher percentage of certified SDVOSB firms included with the design team may provide additional value and potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24725R0069","place_of_performance":{"zip":"29209","city":{"name":"Columbia"},"state":{"code":"SC","name":"South Carolina"},"street":"Department of Veterans Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Wm. Jennings Bryan Dorn VA Medical Center 6439 Garners Ferry Road"},"product_service_code":"C1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-07-22","posted_at":"2025-07-22T19:39:59.297Z","created_at":"2025-07-22T19:39:59.297Z","modified_at":"2025-08-07T03:55:46.543Z","response_deadline":{"raw":"2025-07-29T12:00:00-04:00","utc":"2025-07-29T16:00:00Z","date":"2025-07-29","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4cfecf8490094102923cbe6074d79aa5/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-29","archive_type":"auto_custom"},"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}],"contacts":[{"name":"Christopher Nash Jenkins","role":"primary","email":"christopher.jenkins@va.gov","phone":"478-595-2794","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4cfecf8490094102923cbe6074d79aa5","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"11ec140441c94ea4b8f02bb4204404c9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-08T04:14:06.342726209Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8d3e953d5802edc571f30efacc3afa637ffb8bd46679cbdaf79468de79fd2045","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-08T04:14:06.342726209Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS PRE-SOLICITATION NOTICE IS NOT A REQUEST FOR PROPOSAL. ALL\nINFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED\nHEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL\nINFORMATION WILL BE ISSUED.\n\nProject: 544-23-108 Cast Iron Fittings and Valves Steam Distribution Systems Study\n\nWork Location: Wm. Jennings Bryan Dorn VA Medical Center, Columbia, SC 29209\n\nEstimated/Target Completion Period: 180 Calendar days after Award.\n\nNAICS: 541330 - Engineering Services\n\nSmall Business Standard: $25.5 million\n\nSet-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\n\nSite Visits will not be arranged during this phase.\n\nThe anticipated award date of the proposed A-E Contract is on or before September\n30, 2025.\n\nSF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than\n(NLT) 12:00 PM (EST) February 28, 2025.\n\n***ATTENTION*** Acknowledgement e-mails will be sent from the CO upon receipt of a submission. If an acknowledgement is not returned, the firm should contact the CO at christopher.jenkins@va.gov and 478-595-2794.\n\nPROJECT OVERVIEW:\nThe Columbia VA Health Care System requires a full campus-wide steam distribution survey to accomplished design alert number 003C2B-DA-151, Cast Iron Fittings/Valve Housings, Prohibition of Use in High and Medium Pressure Steam Distribution Systems, 12-15-2021 in addition to Memorandum dated December 13, 2024 related to ASTM A307 fasteners for Steam and hot water heating systems.  Identify the locations of all cast iron, ductile, or malleable fittings, valve housings, piping, and components along with all ASTM A307 fasteners in high pressure and medium pressure steam systems.  This requirement covers systems operating at a pressure of 15 Pounds per Square Inch Gauge (PSIG) or greater and hot water distribution systems for hot water or other liquids at a temperature of greater than 257 degrees Fahrenheit.\n\nSDVOSB SET-ASIDE:\n\nThis requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in SBA VetCert: https://veterans.certify.sba.gov/ prior to submission of proposal and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligibility determination is performed by the Center for Veterans Enterprise (CVE). Eligible SDVOSB concerns must also be registered at the following websites:\n\nSystem for Award Management (SAM): https://www.sam.gov\n\nVETS-4212 Federal Contractor Reporting https://www.dol.gov/agencies/vets/programs/vets4212\n\nImportant Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Department of Veteran Affairs Center for Veterans Enterprise (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so.\n\nFor a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) SBA VetCert: https://veterans.certify.sba.gov/ and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to\ncontract award.\n\nIn order to assure compliance with FAR Clauses, 52.219-14 Limitations on\nSubcontracting (DEVIATION 2019-01) and VAAR 852.219-10, VA Notice of Total\nService-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019)\n(DEVIATION), all firms submitting a SF 330 for this pre-solicitation notice are\nrequired to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as nonresponsive and preclude further evaluation.\n\nFAR Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in FAR 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of Georgia.\n\n\nSELECTION CRITERIA   \n\nSF330s shall be organized in the following order:  \n\nCover Sheet (one-page limit)\nDesign team background with locations of supporting offices (one-page limit)\nDesign team organizational structure with key discipline roles (one-page limit)\nFactor 1   Specialized Experience (one page per project limit) \nFactor 2 - Professional Qualifications (one page per resume limit)\nFactor 3   Past Performance Summary Sheet (one-page limit)\nFactor 4 - Capacity (one-page limit)\nFactor 5   Knowledge or Location (one-page limit)\nFactor 6   SDVOSB Inclusion Statement (one-page limit)\nFull CPARS/PPQs Documentation for Factor 1 Projects (20-page limit) \nAdditional Information (10-page limit)\n\nSF330s received out of sequence will be viewed negatively. \n\nSF330 Specific Requirements:\nAll SF330 pages shall be in PDF searchable for items 1 through 9 and item 11.  Full CPARS and PPQs may be scanned. \nStart each factor response on a new page.\nUse no less than 11-point font.\nAll text and images containing text is legible when printed on 8.5  x 11  paper. The evaluation board will not seek clarification regarding illegible text. \n  \n\nPrimary Selection Criteria (listed in descending order of importance):\n\nFactor 1\nSpecialized Experience (Sections F, G and H): Specialized experience and technical competence in the design and construction period services will be required to perform throughout the life of the contract. Projects experience pertains to the types, size, recency, cost, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation.  \n\nPage Limit   One page per project.  Five-page total for Factor 1.  Information provided on additional pages beyond the one page per project limit or beyond the five-page total limit will not be included with the review. \nRelevant Project Experience: Submit five (5) projects that meet all criteria shown below. \n\nRelevant Project Type   Projects that site investigation and documenting steam line infrastructure conditions and generating P&ID drawings. \nRelevant Project Size   Projects that include Main boiler plants, site distribution infrastructure, and mechanical rooms. \nRelevant Project Recency   Project must be complete or substantially complete within the past five years of the solicitation due date.  Substantially complete is defined as 80% or greater of the project is complete at the time of the solicitation due date.  \nRelevant Project Cost - Construction project cost must be greater than $100,000.00.\nRelevant Project Complexity   The project narrative description must indicate experience with all the following criteria:\nOnsite investigation, reverification, and recording of steam infrastructure system. \nNon-Destructive Investigation and Restoration\nConfined Space Program Implementation\nAnalysis Studies of Steam Infrastructure Systems\n\nThe relevant project criteria listed above is the minimal information required for acceptable project relevance.  Additional value will be considered for projects which convey expertise with the following categories and will potentially increase the overall rating for this factor.  Projects that do not convey additional value expertise will not be considered a weakness. Additional value expertise includes: \n\nExperience with the submitting firm serving as the prime contractor.\nVA relevant project experience.  \nSubmissions shall include no more and no less than five (5) type projects of recent and relevant Government and private experience projects similar in type, size, recency, and complexity, cost, and experience with the type of projects/competence above.\nSection G will used to evaluate the prior experience of the prime firm and any key subcontractors working together as a cohesive unit on the provided relevant projects.  An acceptable rating will be given if all key disciplines are shown, and each discipline participated with at least one project listed on section G. Proposed design team members that do not have experience with any of the five submitted example projects as shown in section G will be viewed negatively.  \n\nFactor 2\nProfessional Qualifications (Sections C through E) necessary for satisfactory performance of required service.  The AE shall demonstrate they are able to sign and stamp each drawing by individuals licensed in any state in the United States for the key positions listed below.  The design firm and A-E staff representing the project must be licensed to practice in any state of the United States of America. Provide Professional License numbers and/or proof of Licensure. The evaluation shall consider the specific experience (minimum of five years) and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full-time employees) of personnel proposed for assignment to the project, and their record of working together as a team when evaluating professional qualifications. The lead designer in each discipline must be registered to sign drawings in each discipline must but does not have to be registered in the state where the project is located. The licensed professional must hold current licensure for said discipline to practice in any state of the United States of America.  Engineer-in -training (EIT) is not considered a professional licensure. \nPage Limit   One page limit per position resume.  Four pages total for Factor 2.  Information provided on additional pages beyond the four-page limit will not be included with the review. \nResume Requirements - A resume for each of these key positions MUST be provided identifying their specific role, via Section E in the SF330. Key positions and disciplines required for this project include, but are not limited to, the lists of professionals with required licensure and preferred licensure below.  An unacceptable rating may be given if resumes are not provided for all roles listed.  \nPositions requiring professional licensure. Not providing the professional licensure will be viewed negatively and will not be compliant with the solicitation. \nMechanical Engineer - PE\n\nKey positions with preferred qualifications. Design team professionals that have obtained the indicated preferred qualifications may be viewed more favorably. Not providing the preferred qualifications will not be viewed negatively and will not reduce the overall rating for this factor.  Higher value may be given for professionals with the preferred qualifications. \n\nQuality Control Manager - Either CQM, CQE, Lean Six Sigma Black Belt, or experience with minimum five projects were served as QC Manager.\nProject Manager - Project Management Professional (PMP) certification or 10 years managing government A/E contracts. \nConstruction Cost Estimator - ASPE Certified Professional Estimator (CPE) Certification\n\nMulti-function roles are allowable for the following positions and may be shown as multi-role positions on the resumes:\nProject Manager and Quality Control Manager\n\nInclude the home office location for each key discipline identified on each respective resume in Section E block 15. \n\nThe criteria listed above is the minimal information required for acceptable professional qualifications.  Additional value will be considered for each key position and will potentially increase the overall rating for this factor and shall not exceed the prescribed page limit.\nFirms holding certification from The American Society of Mechanical Engineers (ASME) for the assembly of pressure piping in accordance with the applicable rules of the ASME Boiler and Pressure Vessel Code (BPVC).  \nKey personnel having greater than 10 years  experience in the practicing field.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \nFactor 3\nPast performance (section H): Past performance will be evaluated on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules along with the firm s history of design error, omission, and/or deficiency claims.  \nPast performance will be evaluated for all projects provided in Section F. The Contractor Performance Assessment Rating System (CPARS) database will be reviewed to evaluate the projects that have a VA CPARS entry. VA CPARS are not required to be submitted with the SF330 submission. However, if the VA CPARS is not included with the SF330 submission, then the contract number for the project must be submitted for each project provided in Section F so CPARS can be reviewed in the database.  Please note we are unable to review any CPARS from other Federal Agencies, outside of the VA.\n\nFor any project that does NOT have VA CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. If the firm (Prime or Subcontractor) was not the Prime Contractor on any project submit-ted in the SF330 a PPQ must be provided listing their specific role as a subcontractor. The PPQ should be rated and signed by the evaluator. In the event that a firm does not receive a requested complete PPQ from an evaluator prior to the time for submission, the firm shall submit the partially completed PPQ with Section 1 and the Evaluator Information in Section 2 completed. Ensure a POC is listed with the project title/contract number. The VA will make reasonable attempts to contact the POC upon submission for PPQ completion.\n\nThe Government may also consider additional performance related information regarding the firm, to include customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. The Government reserves the right to contact any POC listed on a CPARS report or PPQ. If appropriate, the record of significant claims against the firm because of improper or incomplete architectural and engineering services may be evaluated.\n\nFailure to provide requested data, accessible points of contact, or valid phone numbers will result in a firm being considered less qualified. The information for this factor shall be provided in Section H of the SF 330. \n\nFor PPQs, please utilize the attached PPQ document. Completed PPQs should be incorporated into the SF 330 directly. PPQs should not be submitted to the VHA PCAC directly. Any CPARS and PPQs will not be counted towards the page limitations for this submission. However, any narratives provided for past performance in Section H will be counted toward the page limit. \n\nPage Limit   Provide no more than one page total for this factor for the summary page.  Full CPARS/PPQ documentation shall be included on additional pages with the SF330 and shall not exceed 20 pages.  \nProvide a summary page that provides the factor s required information. For each of the five projects, provide the following information. \nProject Information (each project for Specialized Experience)\nPast Performance Record Type (PPQ or CPARS)\nContract Number\nPoint of Contact (Name, Phone, Email, Job Title, POC Role)\nAE Firm Role with Project (Prime or Subcontractor)\nCategory Ratings\n\nProvide complete CPARS (or PPQs if CPARS is not available) for all sample projects after the SF330 Factor 8 section. \n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor.  Locate this documentation after the complete CPARS/PPQ documents.  Additional value documentation shall not exceed five pages.\nLetters of appreciation or accolades from previous projects\nIndustry recognition or design awards\nAny other information the design team wishes to include for this factor so long as the five-page limit is not exceeded. \nFactor 4\nCapacity (section H): The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of key disciplines to perform the work in the required time. Provide the available capacity of key disciplines by providing current project workload, inclusive of all projects awarded by the VA, any Federal Agency, and Private Sector during the previous twelve (12) months and the full potential value of projects forecasted within the next twenty-four (24) months any current indefinite delivery contracts that the firm has.  Include the full potential value of any current indefinite delivery contracts. Offeror shall clearly state their available capacity presenting workload percentages for the key disciplines and/or team members, including sub-consultants. Also, the offeror must provide the completion percentages and expected completion date for all the VA projects current and forecasted. awarded in the previous 12 months. Please ensure the capacity applies toward the team/personnel provided in the SF330.  The information for this factor shall be provided in Section H of the SF330. \nPage Limit   Provide no more than two pages total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review. \nInclude a table that conveys each key discipline, quantity of current design project workload, quantity of current construction period service workload, estimated future design load, estimated future construction workload, quantity of current IDIQ contracts, total IDIQ contract capacity, total remaining IDIQ capacity, and percent the key discipline is available. For example:\n\nKey Discipline\nTotal # of Current Design Project Workload\n# of Current Construction Project Workload\nEstimated # of Future Design Project Workload\nEstimated # of Future Construction Project Workload\nQuantity of current IDIQ contracts involved with\nTotal IDIQ capacity all contracts\n(millions)\nTotal IDIQ remaining capacity\n(millions)\nPercent Available\nCapacity\nArchitect\n6\n7\n6\n7\n4\n$6M\n$2M\n45%\nMechanical Engineer\n4\n8\n3\n8\n2\n$3M\n$1\n10%\nAdd Disciplines as Required\n\n\n\n\n\n\n\n\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Do not include additional pages in the additional information section.\nProviding a narrative conveying the design team s approach on how new work will merge with the current workload. \nProvide a narrative describing the process regarding replacement of key disciplines should one decide to leave the design team.  \nConvey how the design team can maintain schedule if a key discipline member is no longer available?\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \nFactor 5\nKnowledge of Locality (Section H). Knowledge of the locality, to include specific knowledge of certain local conditions or project site features.  The information for this factor shall be provided in Section H of the SF 330. \n\nNote that the intent of this factor is to showcase a firm s understanding of the site and locality, and NOT where the firm is located, how far away the firm/branch office is from the site, and how they would travel to the site.\n\nPage Limit   Page Limit   Provide no more than one page total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review. \nProvide an individual narrative conveying knowledge of the locality for each of the following categories:\nLocal conditions or project site features\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section. \nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded. \n\nFactor 6\nUse of Service- Disabled Veteran-Owned Small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors.  Offerors shall be evaluated based on their utilization plans for service- disabled Veteran- owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation.\n\nPage Limit   Page Limit   Provide no more than one page total for this factor.  Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide a listing of all consulting firms and business government certification(s).  Indicate the anticipated percentage of work the consulting firm will perform.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance.  The higher percentage of certified SDVOSB firms included with the design team may provide additional value and potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.","text":"THIS PRE-SOLICITATION NOTICE IS NOT A REQUEST FOR PROPOSAL. ALL\nINFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED\nHEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL\nINFORMATION WILL BE ISSUED.\n\nProject: 544-23-108 Cast Iron Fittings and Valves Steam Distribution Systems Study\n\nWork Location: Wm. Jennings Bryan Dorn VA Medical Center, Columbia, SC 29209\n\nEstimated/Target Completion Period: 180 Calendar days after Award.\n\nNAICS: 541330 - Engineering Services\n\nSmall Business Standard: $25.5 million\n\nSet-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)\n\nSite Visits will not be arranged during this phase.\n\nThe anticipated award date of the proposed A-E Contract is on or before September\n30, 2025.\n\nSF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than\n(NLT) 12:00 PM (EST) February 28, 2025.\n\n***ATTENTION*** Acknowledgement e-mails will be sent from the CO upon receipt of a submission. If an acknowledgement is not returned, the firm should contact the CO at christopher.jenkins@va.gov and 478-595-2794.\n\nPROJECT OVERVIEW:\nThe Columbia VA Health Care System requires a full campus-wide steam distribution survey to accomplished design alert number 003C2B-DA-151, Cast Iron Fittings/Valve Housings, Prohibition of Use in High and Medium Pressure Steam Distribution Systems, 12-15-2021 in addition to Memorandum dated December 13, 2024 related to ASTM A307 fasteners for Steam and hot water heating systems. Identify the locations of all cast iron, ductile, or malleable fittings, valve housings, piping, and components along with all ASTM A307 fasteners in high pressure and medium pressure steam systems. This requirement covers systems operating at a pressure of 15 Pounds per Square Inch Gauge (PSIG) or greater and hot water distribution systems for hot water or other liquids at a temperature of greater than 257 degrees Fahrenheit.\n\nSDVOSB SET-ASIDE:\n\nThis requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in SBA VetCert: https://veterans.certify.sba.gov/ prior to submission of proposal and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligibility determination is performed by the Center for Veterans Enterprise (CVE). Eligible SDVOSB concerns must also be registered at the following websites:\n\nSystem for Award Management (SAM): https://www.sam.gov\n\nVETS-4212 Federal Contractor Reporting https://www.dol.gov/agencies/vets/programs/vets4212\n\nImportant Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Department of Veteran Affairs Center for Veterans Enterprise (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so.\n\nFor a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) SBA VetCert: https://veterans.certify.sba.gov/ and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to\ncontract award.\n\nIn order to assure compliance with FAR Clauses, 52.219-14 Limitations on\nSubcontracting (DEVIATION 2019-01) and VAAR 852.219-10, VA Notice of Total\nService-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019)\n(DEVIATION), all firms submitting a SF 330 for this pre-solicitation notice are\nrequired to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as nonresponsive and preclude further evaluation.\n\nFAR Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in FAR 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of Georgia.\n\nSELECTION CRITERIA\n\nSF330s shall be organized in the following order:\n\nCover Sheet (one-page limit)\nDesign team background with locations of supporting offices (one-page limit)\nDesign team organizational structure with key discipline roles (one-page limit)\nFactor 1 Specialized Experience (one page per project limit)\nFactor 2 - Professional Qualifications (one page per resume limit)\nFactor 3 Past Performance Summary Sheet (one-page limit)\nFactor 4 - Capacity (one-page limit)\nFactor 5 Knowledge or Location (one-page limit)\nFactor 6 SDVOSB Inclusion Statement (one-page limit)\nFull CPARS/PPQs Documentation for Factor 1 Projects (20-page limit)\nAdditional Information (10-page limit)\n\nSF330s received out of sequence will be viewed negatively.\n\nSF330 Specific Requirements:\nAll SF330 pages shall be in PDF searchable for items 1 through 9 and item 11. Full CPARS and PPQs may be scanned.\nStart each factor response on a new page.\nUse no less than 11-point font.\nAll text and images containing text is legible when printed on 8.5 x 11 paper. The evaluation board will not seek clarification regarding illegible text.\n\nPrimary Selection Criteria (listed in descending order of importance):\n\nFactor 1\nSpecialized Experience (Sections F, G and H): Specialized experience and technical competence in the design and construction period services will be required to perform throughout the life of the contract. Projects experience pertains to the types, size, recency, cost, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation.\n\nPage Limit One page per project. Five-page total for Factor 1. Information provided on additional pages beyond the one page per project limit or beyond the five-page total limit will not be included with the review.\nRelevant Project Experience: Submit five (5) projects that meet all criteria shown below.\n\nRelevant Project Type Projects that site investigation and documenting steam line infrastructure conditions and generating P&ID drawings.\nRelevant Project Size Projects that include Main boiler plants, site distribution infrastructure, and mechanical rooms.\nRelevant Project Recency Project must be complete or substantially complete within the past five years of the solicitation due date. Substantially complete is defined as 80% or greater of the project is complete at the time of the solicitation due date.\nRelevant Project Cost - Construction project cost must be greater than $100,000.00.\nRelevant Project Complexity The project narrative description must indicate experience with all the following criteria:\nOnsite investigation, reverification, and recording of steam infrastructure system.\nNon-Destructive Investigation and Restoration\nConfined Space Program Implementation\nAnalysis Studies of Steam Infrastructure Systems\n\nThe relevant project criteria listed above is the minimal information required for acceptable project relevance. Additional value will be considered for projects which convey expertise with the following categories and will potentially increase the overall rating for this factor. Projects that do not convey additional value expertise will not be considered a weakness. Additional value expertise includes:\n\nExperience with the submitting firm serving as the prime contractor.\nVA relevant project experience.\nSubmissions shall include no more and no less than five (5) type projects of recent and relevant Government and private experience projects similar in type, size, recency, and complexity, cost, and experience with the type of projects/competence above.\nSection G will used to evaluate the prior experience of the prime firm and any key subcontractors working together as a cohesive unit on the provided relevant projects. An acceptable rating will be given if all key disciplines are shown, and each discipline participated with at least one project listed on section G. Proposed design team members that do not have experience with any of the five submitted example projects as shown in section G will be viewed negatively.\n\nFactor 2\nProfessional Qualifications (Sections C through E) necessary for satisfactory performance of required service. The AE shall demonstrate they are able to sign and stamp each drawing by individuals licensed in any state in the United States for the key positions listed below. The design firm and A-E staff representing the project must be licensed to practice in any state of the United States of America. Provide Professional License numbers and/or proof of Licensure. The evaluation shall consider the specific experience (minimum of five years) and qualifications (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the firm as full-time employees) of personnel proposed for assignment to the project, and their record of working together as a team when evaluating professional qualifications. The lead designer in each discipline must be registered to sign drawings in each discipline must but does not have to be registered in the state where the project is located. The licensed professional must hold current licensure for said discipline to practice in any state of the United States of America. Engineer-in -training (EIT) is not considered a professional licensure.\nPage Limit One page limit per position resume. Four pages total for Factor 2. Information provided on additional pages beyond the four-page limit will not be included with the review.\nResume Requirements - A resume for each of these key positions MUST be provided identifying their specific role, via Section E in the SF330. Key positions and disciplines required for this project include, but are not limited to, the lists of professionals with required licensure and preferred licensure below. An unacceptable rating may be given if resumes are not provided for all roles listed.\nPositions requiring professional licensure. Not providing the professional licensure will be viewed negatively and will not be compliant with the solicitation.\nMechanical Engineer - PE\n\nKey positions with preferred qualifications. Design team professionals that have obtained the indicated preferred qualifications may be viewed more favorably. Not providing the preferred qualifications will not be viewed negatively and will not reduce the overall rating for this factor. Higher value may be given for professionals with the preferred qualifications.\n\nQuality Control Manager - Either CQM, CQE, Lean Six Sigma Black Belt, or experience with minimum five projects were served as QC Manager.\nProject Manager - Project Management Professional (PMP) certification or 10 years managing government A/E contracts.\nConstruction Cost Estimator - ASPE Certified Professional Estimator (CPE) Certification\n\nMulti-function roles are allowable for the following positions and may be shown as multi-role positions on the resumes:\nProject Manager and Quality Control Manager\n\nInclude the home office location for each key discipline identified on each respective resume in Section E block 15.\n\nThe criteria listed above is the minimal information required for acceptable professional qualifications. Additional value will be considered for each key position and will potentially increase the overall rating for this factor and shall not exceed the prescribed page limit.\nFirms holding certification from The American Society of Mechanical Engineers (ASME) for the assembly of pressure piping in accordance with the applicable rules of the ASME Boiler and Pressure Vessel Code (BPVC).\nKey personnel having greater than 10 years experience in the practicing field.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\nFactor 3\nPast performance (section H): Past performance will be evaluated on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules along with the firm s history of design error, omission, and/or deficiency claims.\nPast performance will be evaluated for all projects provided in Section F. The Contractor Performance Assessment Rating System (CPARS) database will be reviewed to evaluate the projects that have a VA CPARS entry. VA CPARS are not required to be submitted with the SF330 submission. However, if the VA CPARS is not included with the SF330 submission, then the contract number for the project must be submitted for each project provided in Section F so CPARS can be reviewed in the database. Please note we are unable to review any CPARS from other Federal Agencies, outside of the VA.\n\nFor any project that does NOT have VA CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. If the firm (Prime or Subcontractor) was not the Prime Contractor on any project submit-ted in the SF330 a PPQ must be provided listing their specific role as a subcontractor. The PPQ should be rated and signed by the evaluator. In the event that a firm does not receive a requested complete PPQ from an evaluator prior to the time for submission, the firm shall submit the partially completed PPQ with Section 1 and the Evaluator Information in Section 2 completed. Ensure a POC is listed with the project title/contract number. The VA will make reasonable attempts to contact the POC upon submission for PPQ completion.\n\nThe Government may also consider additional performance related information regarding the firm, to include customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. The Government reserves the right to contact any POC listed on a CPARS report or PPQ. If appropriate, the record of significant claims against the firm because of improper or incomplete architectural and engineering services may be evaluated.\n\nFailure to provide requested data, accessible points of contact, or valid phone numbers will result in a firm being considered less qualified. The information for this factor shall be provided in Section H of the SF 330.\n\nFor PPQs, please utilize the attached PPQ document. Completed PPQs should be incorporated into the SF 330 directly. PPQs should not be submitted to the VHA PCAC directly. Any CPARS and PPQs will not be counted towards the page limitations for this submission. However, any narratives provided for past performance in Section H will be counted toward the page limit.\n\nPage Limit Provide no more than one page total for this factor for the summary page. Full CPARS/PPQ documentation shall be included on additional pages with the SF330 and shall not exceed 20 pages.\nProvide a summary page that provides the factor s required information. For each of the five projects, provide the following information.\nProject Information (each project for Specialized Experience)\nPast Performance Record Type (PPQ or CPARS)\nContract Number\nPoint of Contact (Name, Phone, Email, Job Title, POC Role)\nAE Firm Role with Project (Prime or Subcontractor)\nCategory Ratings\n\nProvide complete CPARS (or PPQs if CPARS is not available) for all sample projects after the SF330 Factor 8 section.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Locate this documentation after the complete CPARS/PPQ documents. Additional value documentation shall not exceed five pages.\nLetters of appreciation or accolades from previous projects\nIndustry recognition or design awards\nAny other information the design team wishes to include for this factor so long as the five-page limit is not exceeded.\nFactor 4\nCapacity (section H): The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of key disciplines to perform the work in the required time. Provide the available capacity of key disciplines by providing current project workload, inclusive of all projects awarded by the VA, any Federal Agency, and Private Sector during the previous twelve (12) months and the full potential value of projects forecasted within the next twenty-four (24) months any current indefinite delivery contracts that the firm has. Include the full potential value of any current indefinite delivery contracts. Offeror shall clearly state their available capacity presenting workload percentages for the key disciplines and/or team members, including sub-consultants. Also, the offeror must provide the completion percentages and expected completion date for all the VA projects current and forecasted. awarded in the previous 12 months. Please ensure the capacity applies toward the team/personnel provided in the SF330. The information for this factor shall be provided in Section H of the SF330.\nPage Limit Provide no more than two pages total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nInclude a table that conveys each key discipline, quantity of current design project workload, quantity of current construction period service workload, estimated future design load, estimated future construction workload, quantity of current IDIQ contracts, total IDIQ contract capacity, total remaining IDIQ capacity, and percent the key discipline is available. For example:\n\nKey Discipline\nTotal # of Current Design Project Workload\n# of Current Construction Project Workload\nEstimated # of Future Design Project Workload\nEstimated # of Future Construction Project Workload\nQuantity of current IDIQ contracts involved with\nTotal IDIQ capacity all contracts\n(millions)\nTotal IDIQ remaining capacity\n(millions)\nPercent Available\nCapacity\nArchitect\n6\n7\n6\n7\n4\n$6M\n$2M\n45%\nMechanical Engineer\n4\n8\n3\n8\n2\n$3M\n$1\n10%\nAdd Disciplines as Required\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor. Do not include additional pages in the additional information section.\nProviding a narrative conveying the design team s approach on how new work will merge with the current workload.\nProvide a narrative describing the process regarding replacement of key disciplines should one decide to leave the design team.\nConvey how the design team can maintain schedule if a key discipline member is no longer available?\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\nFactor 5\nKnowledge of Locality (Section H). Knowledge of the locality, to include specific knowledge of certain local conditions or project site features. The information for this factor shall be provided in Section H of the SF 330.\n\nNote that the intent of this factor is to showcase a firm s understanding of the site and locality, and NOT where the firm is located, how far away the firm/branch office is from the site, and how they would travel to the site.\n\nPage Limit Page Limit Provide no more than one page total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide an individual narrative conveying knowledge of the locality for each of the following categories:\nLocal conditions or project site features\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. Additional value will be considered for each additional item below and may potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.\nAny other information the design team wishes to include for this factor so long as the page limit is not exceeded.\n\nFactor 6\nUse of Service- Disabled Veteran-Owned Small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Offerors shall be evaluated based on their utilization plans for service- disabled Veteran- owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation.\n\nPage Limit Page Limit Provide no more than one page total for this factor. Information provided on additional pages beyond the one-page limit will not be included with the review.\nProvide a listing of all consulting firms and business government certification(s). Indicate the anticipated percentage of work the consulting firm will perform.\n\nThe criteria listed above is the minimal information required for acceptable factor compliance. The higher percentage of certified SDVOSB firms included with the design team may provide additional value and potentially increase the overall rating for this factor so long as the page limit is not exceeded. Do not include additional pages in the additional information section.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24725R0069","place_of_performance":{"zip":"29209","city":{"name":"Columbia"},"state":{"code":"SC","name":"South Carolina"},"street":"Department of Veterans Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Wm. Jennings Bryan Dorn VA Medical Center 6439 Garners Ferry Road"},"product_service_code":"C1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-07-23","posted_at":"2025-07-23T18:18:37.894Z","created_at":"2025-07-23T18:18:35.479Z","modified_at":"2025-08-07T03:55:46.543Z","response_deadline":{"raw":"2025-07-30T12:00:00-04:00","utc":"2025-07-30T16:00:00Z","date":"2025-07-30","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/162032ef6893413f9605637fadc972f7/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-06","archive_type":"auto_custom"},"history":[{"index":6,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-23T18:18:37.894Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"162032ef6893413f9605637fadc972f7","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":4,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-22T19:39:59.297Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4cfecf8490094102923cbe6074d79aa5","solicitation_number":"36C24725R0069","parent_opportunity_id":"11ec140441c94ea4b8f02bb4204404c9"},{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T17:15:59.114Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"11ec140441c94ea4b8f02bb4204404c9","solicitation_number":"36C24725R0069"}],"contacts":[{"name":"C Nash Jenkins","role":"primary","email":"christopher.jenkins@va.gov","phone":"(770) 279-0000","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"162032ef6893413f9605637fadc972f7","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"11ec140441c94ea4b8f02bb4204404c9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-08T03:06:16.946750101Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"cc28b1bdac49b09a798e4d63210b40a448adb71c0e8c5e8f231345063d4ca9b6","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-08T03:06:16.946750101Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Notice of Amendment: SF 330 Submissions for Pre-Solicitation Notice 36C24725R0069\n\nThis notice amends the original Pre-Solicitation Notice 36C24725R0069 issued on January 29, 2025, to include VAAR Clause 852.219-75,  Notice of Limitations on Subcontracting   Certificate of Compliance for Services and Construction. \n\nAction Required:\nVendors who previously submitted an SF 330 in response to Pre-Solicitation Notice 36C24725R0069 must now complete and submit the attached VAAR 852.219-75 Certificate of Compliance to be considered for evaluation or award.\n\nImportant Notes:\n\n  Only vendors who submitted an SF 330 under the original notice will be evaluated.\n  Modifications to previously submitted SF 330s are not allowed.\n  Do not resubmit your SF 330. Submit only the signed certificate.\n\n\nIf you remain interested, please review, complete, and sign the attached VAAR 852.219-75 Certificate of Compliance.","text":"Notice of Amendment: SF 330 Submissions for Pre-Solicitation Notice 36C24725R0069\n\nThis notice amends the original Pre-Solicitation Notice 36C24725R0069 issued on January 29, 2025, to include VAAR Clause 852.219-75, Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\n\nAction Required:\nVendors who previously submitted an SF 330 in response to Pre-Solicitation Notice 36C24725R0069 must now complete and submit the attached VAAR 852.219-75 Certificate of Compliance to be considered for evaluation or award.\n\nImportant Notes:\n\nOnly vendors who submitted an SF 330 under the original notice will be evaluated.\nModifications to previously submitted SF 330s are not allowed.\nDo not resubmit your SF 330. Submit only the signed certificate.\n\nIf you remain interested, please review, complete, and sign the attached VAAR 852.219-75 Certificate of Compliance.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24725R0069","place_of_performance":{"zip":"29209","city":{"name":"Columbia"},"state":{"name":"SC"},"street2":"Wm. Jennings Bryan Dorn VAMC 6439 Garners Ferry Road"},"product_service_code":"C1DA"},{"award":{"date":"2025-09-18","amount":"836735.25","number":"36C24725C0110","awardee":{"raw":"KSM A&E FEDERAL GROUP, LLC SAINT PETERSBURG 33713 FLK","uei":"EMAZMNNC13M7","cage":"96XQ3","name":"KSM A&E FEDERAL GROUP, LLC","location":{"zip":"33713","city":{"name":"SAINT PETERSBURG"},"state":{"name":"FL"},"country":{"code":"FLK","name":"FALKLAND ISLANDS (ISLAS MALVINAS)"}}}},"dates":{"posted":"2025-09-22","posted_at":"2025-09-22T19:53:09.438Z","award_date":"2025-09-18","created_at":"2025-09-22T19:53:07.150Z","modified_at":"2025-09-30T04:00:16.420Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/8db96d77a7a84d79aeb44e97d5bfa352/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","agency":{"office":{"code":"36C247","name":"247-NETWORK CONTRACT OFFICE 7 (36C247)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"organization_id":"100170297","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"C1DA--PROJECT 544-23-108 - 544-25-2-5280-0003 Replace Cast Iron Fittings and Valves Steam Distribution Systems Study (VA-25-00008204)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T19:53:09.438Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8db96d77a7a84d79aeb44e97d5bfa352","solicitation_number":"36C24725R0069"}],"contacts":[{"name":"C. Nash Jenkins","role":"primary","email":"christopher.jenkins@va.gov","phone":"478-595-2794","title":"Contracting Officer"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"8db96d77a7a84d79aeb44e97d5bfa352","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"8db96d77a7a84d79aeb44e97d5bfa352","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-29T00:57:24.220089107Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"2fd7ee786e8a57cf1f16d054b1a1a47c2a1f1e8bdd6bb8607a6159e0e3a5d427","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-29T00:57:24.220089107Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24725R0069","product_service_code":"C1DA"}],"due_at":"2025-07-30T16:00:00Z","due_date":"2025-07-30","closes_at":"2025-07-30T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","state":"SC","county":"45079","county_name":"Richland County","city":"4516000","city_name":"Columbia","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"EMAZMNNC13M7","amount":"836735.25","linked_awards":4,"cancelled":false,"archived":true,"updated_at":"2026-10-29T01:15:19.167857Z","principal_notice_id":"162032ef6893413f9605637fadc972f7","description":{"text":"Notice of Amendment: SF 330 Submissions for Pre-Solicitation Notice 36C24725R0069\n\nThis notice amends the original Pre-Solicitation Notice 36C24725R0069 issued on January 29, 2025, to include VAAR Clause 852.219-75, Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\n\nAction Required:\nVendors who previously submitted an SF 330 in response to Pre-Solicitation Notice 36C24725R0069 must now complete and submit the attached VAAR 852.219-75 Certificate of Compliance to be considered for evaluation or award.\n\nImportant Notes:\n\nOnly vendors who submitted an SF 330 under the original notice will be evaluated.\nModifications to previously submitted SF 330s are not allowed.\nDo not resubmit your SF 330. Submit only the signed certificate.\n\nIf you remain interested, please review, complete, and sign the attached VAAR 852.219-75 Certificate of Compliance.","html":"Notice of Amendment: SF 330 Submissions for Pre-Solicitation Notice 36C24725R0069\n\nThis notice amends the original Pre-Solicitation Notice 36C24725R0069 issued on January 29, 2025, to include VAAR Clause 852.219-75,  Notice of Limitations on Subcontracting   Certificate of Compliance for Services and Construction. \n\nAction Required:\nVendors who previously submitted an SF 330 in response to Pre-Solicitation Notice 36C24725R0069 must now complete and submit the attached VAAR 852.219-75 Certificate of Compliance to be considered for evaluation or award.\n\nImportant Notes:\n\n  Only vendors who submitted an SF 330 under the original notice will be evaluated.\n  Modifications to previously submitted SF 330s are not allowed.\n  Do not resubmit your SF 330. Submit only the signed certificate.\n\n\nIf you remain interested, please review, complete, and sign the attached VAAR 852.219-75 Certificate of Compliance.","origin":"detail"},"contacts":[{"name":"C. Nash Jenkins","role":"primary","email":"christopher.jenkins@va.gov","phone":"478-595-2794","title":"Contracting Officer"}],"place_of_performance":{"zip":"29209","city":{"name":"Columbia"},"state":{"name":"SC"},"street2":"Wm. Jennings Bryan Dorn VAMC 6439 Garners Ferry Road"},"office_address":{"zip":"30904","city":"AUGUSTA","state":"GA","country":"USA"},"naics_codes":["541330"],"award":{"awardee":{}},"attachments":[{"resource_id":"257cff59c6d44c58b7398ff2b2e9e593","name":"36C24725C0110_1.docx","kind":"file","mime_type":".docx","size_bytes":13737,"posted_at":"2025-09-22T19:53:09.438Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/257cff59c6d44c58b7398ff2b2e9e593/download","mirrored":false},{"resource_id":"01792e69acf540d9809f9d7c1d8e699b","name":"36C24725R0069.docx","kind":"file","mime_type":".docx","size_bytes":109996,"posted_at":"2025-01-29T17:15:59.114Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/01792e69acf540d9809f9d7c1d8e699b/download","mirrored":false},{"resource_id":"71edd5feecf844aca9cef63989ae3bb1","name":"U.S. Department of Veteran Affairs","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-01-29T17:15:59.114Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24725C0110_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24725C0110_3600_-NONE-_-NONE-/","piid":"36C24725C0110","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"EMAZMNNC13M7","recipient_name":"KSM A&E FEDERAL GROUP, LLC","recipient_uei":"EMAZMNNC13M7","recipient_cage":"96XQ3","recipient_city":"SAINT PETERSBURG","recipient_state":"FL","sub_name":"Department of Veterans Affairs","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","office_key":"o-36C247","first_action_date":"2025-09-18","last_action_date":"2026-06-24","actions":2,"obligated":"836735.25","current_total_value":"836735.25","potential_total_value":"836735.25","naics":"541330","psc":"C1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":9,"description":"CAST IRON FITTINGS AND VALVES STEAM DISTRIBUTION SYSTEMS STUDY","method":"piid","confidence":"high","evidence":["award number 36C24725C0110 equals the contract number","same awarding office 36C247"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24727Q0118","latest_notice_id":"27bcc9cdef604254982ea444d657d39d","title":"6515--STERILIZATION CONTAINERS","solicitation_number":"36C24727Q0118","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339113","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24726R0134","latest_notice_id":"8f0c90b43099494cb8a8201cd475406f","title":"Y1DA | 521-24-102 | Renovate Wards 2K and 2B for Optometry/Ophthalmology Clinical Use","solicitation_number":"36C24726R0134","notice_type":"o","first_type":"p","first_posted":"2026-09-25","last_posted":"2026-11-18","notices":7,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"AL","county":"01073","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24727Q0067","latest_notice_id":"f75d8541b0604a57a55c64094b365d82","title":"J065--Building 3 Dental Vacuum Pump Replacement","solicitation_number":"36C24727Q0067","notice_type":"k","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":6,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"GA","county":"13175","county_name":"Laurens County","city":"1324376","city_name":"Dublin","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24727Q0115","latest_notice_id":"58ac14c8858846ce9a8d172472648821","title":"C1DA--544-27-110 | Update Facility Masterplan Architect and Engineering","solicitation_number":"36C24727Q0115","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"541330","psc":"C1DA","set_aside":"SDVOSBC","state":"SC","county":"45079","county_name":"Richland County","city":"4516000","city_name":"Columbia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"36C24727Q0115","latest_notice_id":"58ac14c8858846ce9a8d172472648821","title":"C1DA--544-27-110 | Update Facility Masterplan Architect and Engineering","solicitation_number":"36C24727Q0115","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"541330","psc":"C1DA","set_aside":"SDVOSBC","state":"SC","county":"45079","county_name":"Richland County","city":"4516000","city_name":"Columbia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"N6523626RFPREQLSUBP000350009","latest_notice_id":"4acab565b2234c349c353ec3adc9b107","title":"SUBMARINE C4ISR SYSTEMS TECH SUPPORT, INSTALLATION AND MODERNIZATION","solicitation_number":"N65236-26-RFPREQ-LSUBP00035-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-19","notices":3,"due_at":"2026-12-11T22:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N65236","office_name":"NIWC ATLANTIC","naics":"541330","psc":"L059","set_aside":null,"state":"SC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"ONE INNOVATION DRIVE HANAHAN, SC 29406","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"25RFPREQLSUBP000300031","latest_notice_id":"47c2b96314e84cf3979cd1c0905fa73e","title":"Indefinite-Delivery, Indefinite-Quantity (IDIQ) for Architect-Engineer (A-E) Design and Related Services at Naval Information Warfare Center (NIWC) Atlantic","solicitation_number":"25-RFPREQ-LSUBP00030-0031","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-29T19:00:00Z","due_date":"2026-12-29","closes_at":"2026-12-29T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N65236","office_name":"NIWC ATLANTIC","naics":"541330","psc":"C219","set_aside":"SBA","state":"SC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"NIWC ATLANTIC - HANAHAN, SC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":100,"indexable":false}