{"canonical":"https://sealedbidder.com/opportunities/36c24627b0001","key":"36C24627B0001","url":"https://sealedbidder.com/opportunities/36c24627b0001","title":"Correct Electrical Deficiencies","solicitation_number":"36C24627B0001","notice_type":"o","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-12-08T15:00:00Z","first_posted":"2026-09-21","last_posted":"2026-11-19","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"6150","set_aside":"SDVOSBC","place_state":"NC","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"37051","place_county_name":"Cumberland County","place_city":"3722920","place_city_name":"Fayetteville","winner":null,"award_amount":null,"publications":[{"notice_id":"2b09d3389e514695959b6e38457fd6b6","title":"6150--Correct Electrical Deficiencies","solicitation_number":"36C24627B0001","notice_type":"p","base_type":"p","posted":"2026-09-21","posted_at":"2026-09-21T19:26:15.796Z","due_at":"2026-10-15T14:00:00Z","due_date":"2026-10-15","cancelled":null,"archived":null,"archive_date":"2027-01-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2b09d3389e514695959b6e38457fd6b6/view","enriched":true,"history":[{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}]},{"notice_id":"33cea54e56594fd4a20fb45b1905b49a","title":"Correct Electrical Deficiencies","solicitation_number":"36C24627B0001","notice_type":"o","base_type":"p","posted":"2026-11-04","posted_at":"2026-11-05T00:14:33.917Z","due_at":"2026-12-08T15:00:00Z","due_date":"2026-12-08","cancelled":false,"archived":false,"archive_date":"2026-12-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/33cea54e56594fd4a20fb45b1905b49a/view","enriched":true,"history":[{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}]},{"notice_id":"eed5595d885240c2b6ba126a46448b9d","title":"Correct Electrical Deficiencies","solicitation_number":"36C24627B0001","notice_type":"o","base_type":"o","posted":"2026-11-05","posted_at":"2026-11-05T13:39:42.298Z","due_at":"2026-12-08T15:00:00Z","due_date":"2026-12-08","cancelled":false,"archived":false,"archive_date":"2026-12-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eed5595d885240c2b6ba126a46448b9d/view","enriched":true,"history":[{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}]},{"notice_id":"85f2f5bda6d04610834f65fad3493f4b","title":"Correct Electrical Deficiencies","solicitation_number":"36C24627B0001","notice_type":"o","base_type":"o","posted":"2026-11-19","posted_at":"2026-11-20T01:46:58.090Z","due_at":"2026-12-08T15:00:00Z","due_date":"2026-12-08","cancelled":false,"archived":false,"archive_date":"2026-12-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/85f2f5bda6d04610834f65fad3493f4b/view","enriched":true,"history":[{"index":4,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-20T01:46:58.090Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"85f2f5bda6d04610834f65fad3493f4b","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}]}],"latest_notice_id":"85f2f5bda6d04610834f65fad3493f4b","first_type":"p","notices":[{"dates":{"posted":"2026-09-21","posted_at":"2026-09-21T19:26:15.796Z","created_at":"2026-09-21T19:25:45.738Z","modified_at":"2026-09-21T19:26:15.796Z","response_deadline":{"raw":"2026-10-15T10:00:00-04:00","utc":"2026-10-15T14:00:00Z","date":"2026-10-15","time":"10:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2b09d3389e514695959b6e38457fd6b6/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"6150--Correct Electrical Deficiencies","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2027-01-22","archive_type":"auto_custom"},"history":[{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}],"contacts":[{"name":"Angelo Harris","role":"primary","email":"angelo.harris@va.gov","phone":"910-488-2120","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"2b09d3389e514695959b6e38457fd6b6","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"2b09d3389e514695959b6e38457fd6b6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-22T04:43:35.151462926Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"e6744da4f9a914bbce241ff61e1903a6e4bbd72d62464b8cd5e47294dbce5331","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-22T04:18:56.687806512Z"},"description":{"html":"The intent of the project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout campus, and minor HVAC and Plumbing improvements.\nEstimated construction magnitude is between $10,000,000.00 and $20,000,000.00\nNAICS CODE: 236220 Size Standard: $45.0 Million    \nPeriod of performance:   1,174 (one thousand, one hundred seventy-four) Days\nAll non-responsive bids shall be rejected and ineligible for award.\nNetwork Contracting Office 6 (NCO 6) intends to issue an Invitation for Bid (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on or around October 15, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Bids will be due approximately 30 days after issuance of the solicitation. Only one site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. \nThis notice is for informational purposes only and is not an invitation for bids. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No bidders list is maintained. All interested vendors should register on SAM.gov. Interested bidders are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. \nAny questions regarding this announcement and all future announcements regarding this project must be emailed to the Primary Contract Specialist, Angelo Harris, at angelo.harris@va.gov.   \nNO TELEPHONE REQUESTS FOR BIDDING MATERIAL WILL BE ACCEPTED.","text":"The intent of the project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout campus, and minor HVAC and Plumbing improvements.\nEstimated construction magnitude is between $10,000,000.00 and $20,000,000.00\nNAICS CODE: 236220 Size Standard: $45.0 Million\nPeriod of performance: 1,174 (one thousand, one hundred seventy-four) Days\nAll non-responsive bids shall be rejected and ineligible for award.\nNetwork Contracting Office 6 (NCO 6) intends to issue an Invitation for Bid (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on or around October 15, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Bids will be due approximately 30 days after issuance of the solicitation. Only one site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation.\nThis notice is for informational purposes only and is not an invitation for bids. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No bidders list is maintained. All interested vendors should register on SAM.gov. Interested bidders are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal.\nAny questions regarding this announcement and all future announcements regarding this project must be emailed to the Primary Contract Specialist, Angelo Harris, at angelo.harris@va.gov.\nNO TELEPHONE REQUESTS FOR BIDDING MATERIAL WILL BE ACCEPTED.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24627B0001","place_of_performance":{"zip":"28301","city":{"name":"Fayetteville"},"state":{"code":"NC"},"street":"2300 Ramsey St.","country":{"code":"USA"}},"product_service_code":"6150"},{"dates":{"posted":"2026-11-04","posted_at":"2026-11-05T00:14:33.917Z","created_at":"2026-11-04T23:58:54.974Z","modified_at":"2026-11-05T13:39:42.298Z","response_deadline":{"raw":"2026-12-08T10:00:00-05:00","utc":"2026-12-08T15:00:00Z","date":"2026-12-08","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/33cea54e56594fd4a20fb45b1905b49a/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Correct Electrical Deficiencies","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-23","archive_type":"auto15"},"history":[{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}],"contacts":[{"name":"Angelo Harris","role":"primary","email":"angelo.harris@va.gov","phone":"910-488-2120","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"33cea54e56594fd4a20fb45b1905b49a","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"33cea54e56594fd4a20fb45b1905b49a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-06T00:06:22.059104488Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"c2e5e832dbb64695d05b6735b2e259aa6568e33ead8478aae2971d4f02892c3d","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-11-05T04:33:40.972004995Z"},"description":{"html":"<p>SOW&nbsp;<br />\n565-22-500 Correct Electrical Deficiencies&nbsp;<br />\nFayetteville VAMC</p>\n\n<p>Intent<br />\nThe project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. &nbsp;Period of performance 1,174 calendar days.<br />\nMedium Voltage<br />\nVA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope:<br />\nReplace existing medium voltage entrance equipment with new at campus entrance.&nbsp;<br />\nProvide new building:<br />\nSlab on grade, brick on CMU wall, Slate roof tile (to match existing facility)<br />\nProvide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 .<br />\nDemo and remove old VA owned medium voltage entrance metal shack.<br />\nReplace medium voltage sectionalized switch.&nbsp;<br />\nProvide new metal-clad switchgear with draw-out vacuum circuit breakers.<br />\nReplace medium voltage oil filled transformer (1)<br />\nPanel Replacement and Branch Circuit Improvements<br />\nCorrect deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o&nbsp;</p>\n\n<p>All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include:<br />\nReplace-in-same-room building entrance and large distribution equipment:<br />\nNormal (service entrance) Switchboards: approx. 2&nbsp;<br />\nGenerator switchboards: approx. 2&nbsp;<br />\nAutomatic transfer switch: approx. 7<br />\nReplace-in-place distribution panels and panelboards distribution equipment<br />\nDistribution Panels: approx. 5<br />\nPanelboards: approx. 68<br />\nReplace undersized feeders<br />\nRedundant Gound<br />\nProvide redundant equipment grounding conductor to a portion of the facility.<br />\nApprox. 100,000 square feet of existing electrical branch circuit distribution in occupied space.&nbsp;<br />\nHVAC And Plumbing<br />\nReroute (vertically &amp; horizontally) Sewer piping and hot water piping to avoid electrical room.<br />\nProvide exhaust fan to new Medium Voltage building.&nbsp;<br />\nIncidental Electrical Equipment Cleanup<br />\nProvide Identification tag to new and existing equipment throughout the facility: approx. 100 tags<br />\nClean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures.<br />\nCorrect panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels.</p>\n\n<p>ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.<br />\n&nbsp;</p>","text":"SOW\n\n565-22-500 Correct Electrical Deficiencies\n\nFayetteville VAMC\n\nIntent\n\nThe project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days.\n\nMedium Voltage\n\nVA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope:\n\nReplace existing medium voltage entrance equipment with new at campus entrance.\n\nProvide new building:\n\nSlab on grade, brick on CMU wall, Slate roof tile (to match existing facility)\n\nProvide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 .\n\nDemo and remove old VA owned medium voltage entrance metal shack.\n\nReplace medium voltage sectionalized switch.\n\nProvide new metal-clad switchgear with draw-out vacuum circuit breakers.\n\nReplace medium voltage oil filled transformer (1)\n\nPanel Replacement and Branch Circuit Improvements\n\nCorrect deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o\n\nAll work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include:\n\nReplace-in-same-room building entrance and large distribution equipment:\n\nNormal (service entrance) Switchboards: approx. 2\n\nGenerator switchboards: approx. 2\n\nAutomatic transfer switch: approx. 7\n\nReplace-in-place distribution panels and panelboards distribution equipment\n\nDistribution Panels: approx. 5\n\nPanelboards: approx. 68\n\nReplace undersized feeders\n\nRedundant Gound\n\nProvide redundant equipment grounding conductor to a portion of the facility.\n\nApprox. 100,000 square feet of existing electrical branch circuit distribution in occupied space.\n\nHVAC And Plumbing\n\nReroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room.\n\nProvide exhaust fan to new Medium Voltage building.\n\nIncidental Electrical Equipment Cleanup\n\nProvide Identification tag to new and existing equipment throughout the facility: approx. 100 tags\n\nClean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures.\n\nCorrect panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels.\n\nALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24627B0001","place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6150"},{"dates":{"posted":"2026-11-05","posted_at":"2026-11-05T13:39:42.298Z","created_at":"2026-11-05T13:37:56.836Z","modified_at":"2026-11-05T13:39:42.306Z","response_deadline":{"raw":"2026-12-08T10:00:00-05:00","utc":"2026-12-08T15:00:00Z","date":"2026-12-08","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eed5595d885240c2b6ba126a46448b9d/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Correct Electrical Deficiencies","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_id":"100167096","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-23","archive_type":"auto15"},"history":[{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}],"contacts":[{"name":"Angelo Harris","role":"primary","email":"angelo.harris@va.gov","phone":"910-488-2120","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"eed5595d885240c2b6ba126a46448b9d","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"33cea54e56594fd4a20fb45b1905b49a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T09:57:49.463256879Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"a42940d99b1cbd79f104e8ec162a2c9aafaa78222807be30922f5c0ca2bcd92f","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-11T09:57:49.463256879Z","first_seen_at":"2026-11-06T04:42:59.950874882Z"},"description":{"html":"<p>SOW&nbsp;<br />\n565-22-500 Correct Electrical Deficiencies&nbsp;<br />\nFayetteville VAMC</p>\n\n<p>Intent<br />\nThe project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. &nbsp;Period of performance 1,174 calendar days.<br />\nMedium Voltage<br />\nVA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope:<br />\nReplace existing medium voltage entrance equipment with new at campus entrance.&nbsp;<br />\nProvide new building:<br />\nSlab on grade, brick on CMU wall, Slate roof tile (to match existing facility)<br />\nProvide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 .<br />\nDemo and remove old VA owned medium voltage entrance metal shack.<br />\nReplace medium voltage sectionalized switch.&nbsp;<br />\nProvide new metal-clad switchgear with draw-out vacuum circuit breakers.<br />\nReplace medium voltage oil filled transformer (1)<br />\nPanel Replacement and Branch Circuit Improvements<br />\nCorrect deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o&nbsp;</p>\n\n<p>All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include:<br />\nReplace-in-same-room building entrance and large distribution equipment:<br />\nNormal (service entrance) Switchboards: approx. 2&nbsp;<br />\nGenerator switchboards: approx. 2&nbsp;<br />\nAutomatic transfer switch: approx. 7<br />\nReplace-in-place distribution panels and panelboards distribution equipment<br />\nDistribution Panels: approx. 5<br />\nPanelboards: approx. 68<br />\nReplace undersized feeders<br />\nRedundant Gound<br />\nProvide redundant equipment grounding conductor to a portion of the facility.<br />\nApprox. 100,000 square feet of existing electrical branch circuit distribution in occupied space.&nbsp;<br />\nHVAC And Plumbing<br />\nReroute (vertically &amp; horizontally) Sewer piping and hot water piping to avoid electrical room.<br />\nProvide exhaust fan to new Medium Voltage building.&nbsp;<br />\nIncidental Electrical Equipment Cleanup<br />\nProvide Identification tag to new and existing equipment throughout the facility: approx. 100 tags<br />\nClean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures.<br />\nCorrect panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels.</p>\n\n<p>ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.<br />\n&nbsp;</p>","text":"SOW\n\n565-22-500 Correct Electrical Deficiencies\n\nFayetteville VAMC\n\nIntent\n\nThe project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days.\n\nMedium Voltage\n\nVA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope:\n\nReplace existing medium voltage entrance equipment with new at campus entrance.\n\nProvide new building:\n\nSlab on grade, brick on CMU wall, Slate roof tile (to match existing facility)\n\nProvide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 .\n\nDemo and remove old VA owned medium voltage entrance metal shack.\n\nReplace medium voltage sectionalized switch.\n\nProvide new metal-clad switchgear with draw-out vacuum circuit breakers.\n\nReplace medium voltage oil filled transformer (1)\n\nPanel Replacement and Branch Circuit Improvements\n\nCorrect deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o\n\nAll work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include:\n\nReplace-in-same-room building entrance and large distribution equipment:\n\nNormal (service entrance) Switchboards: approx. 2\n\nGenerator switchboards: approx. 2\n\nAutomatic transfer switch: approx. 7\n\nReplace-in-place distribution panels and panelboards distribution equipment\n\nDistribution Panels: approx. 5\n\nPanelboards: approx. 68\n\nReplace undersized feeders\n\nRedundant Gound\n\nProvide redundant equipment grounding conductor to a portion of the facility.\n\nApprox. 100,000 square feet of existing electrical branch circuit distribution in occupied space.\n\nHVAC And Plumbing\n\nReroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room.\n\nProvide exhaust fan to new Medium Voltage building.\n\nIncidental Electrical Equipment Cleanup\n\nProvide Identification tag to new and existing equipment throughout the facility: approx. 100 tags\n\nClean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures.\n\nCorrect panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels.\n\nALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24627B0001","place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6150"},{"dates":{"posted":"2026-11-19","posted_at":"2026-11-20T01:46:58.090Z","created_at":"2026-11-20T01:05:21.625Z","modified_at":"2026-11-20T01:46:58.095Z","response_deadline":{"raw":"2026-12-08T10:00:00-05:00","utc":"2026-12-08T15:00:00Z","date":"2026-12-08","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/85f2f5bda6d04610834f65fad3493f4b/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Correct Electrical Deficiencies","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_id":"100167096","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-23","archive_type":"auto15"},"history":[{"index":4,"title":"Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-20T01:46:58.090Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"85f2f5bda6d04610834f65fad3493f4b","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":3,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T13:39:42.298Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"eed5595d885240c2b6ba126a46448b9d","solicitation_number":"36C24627B0001","parent_opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":2,"title":"Correct Electrical Deficiencies","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-05T00:14:33.917Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"33cea54e56594fd4a20fb45b1905b49a","solicitation_number":"36C24627B0001","related_opportunity_id":"2b09d3389e514695959b6e38457fd6b6"},{"index":1,"title":"6150--Correct Electrical Deficiencies","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:26:15.796Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"2b09d3389e514695959b6e38457fd6b6","solicitation_number":"36C24627B0001"}],"contacts":[{"name":"Angelo Harris","role":"primary","email":"angelo.harris@va.gov","phone":"910-488-2120","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"85f2f5bda6d04610834f65fad3493f4b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"33cea54e56594fd4a20fb45b1905b49a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T07:41:34.905002261Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"c16e5e0dfa0d95d43d743e49e58247ca-28\"","fetched_at":"2026-11-20T05:29:17.372835729Z","row_sha256":"f01894758a2205b3de54d2f82e90ce0065acd434735328383fd1e00e753d0a8a","last_modified":"2026-11-20T04:30:19Z"},"updated_at":"2026-11-20T07:41:34.905002261Z","first_seen_at":"2026-11-20T05:29:17.372835729Z"},"description":{"html":"<p>This amendment (001) is to provide the sign in sheet from the site visit held 12 November 2026, as well as provide additional information reference outage plan, hazmat and circuit survey.</p>","text":"This amendment (001) is to provide the sign in sheet from the site visit held 12 November 2026, as well as provide additional information reference outage plan, hazmat and circuit survey.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24627B0001","place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6150"}],"due_at":"2026-12-08T15:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-20T05:30:09.595354Z","principal_notice_id":"85f2f5bda6d04610834f65fad3493f4b","description":{"text":"This amendment (001) is to provide the sign in sheet from the site visit held 12 November 2026, as well as provide additional information reference outage plan, hazmat and circuit survey.","html":"<p>This amendment (001) is to provide the sign in sheet from the site visit held 12 November 2026, as well as provide additional information reference outage plan, hazmat and circuit survey.</p>","origin":"detail"},"contacts":[{"name":"Angelo Harris","role":"primary","email":"angelo.harris@va.gov","phone":"910-488-2120","title":"Contracting Officer"}],"place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"naics_codes":["236220"],"award":null,"attachments":[{"resource_id":"7d24023cb6c244359d4a544b41537208","name":"36C24627B0001_1.docx","kind":"file","mime_type":".docx","size_bytes":16024,"posted_at":"2026-09-21T19:26:15.796Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7d24023cb6c244359d4a544b41537208/download","mirrored":false},{"resource_id":"29e6d67e83804f3882e43b6615220efd","name":"ATTACHMENT - BAA TAA COMPLIANCE CERTIFICATION.docx","kind":"file","mime_type":".docx","size_bytes":21409,"posted_at":"2026-11-05T00:14:33.917Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/29e6d67e83804f3882e43b6615220efd/download","mirrored":false},{"resource_id":"dfdec00c876c4ccdae3c51b3e1f7129f","name":"Correct Electrical Deficiencies Specifications.pdf","kind":"file","mime_type":".pdf","size_bytes":3378030,"posted_at":"2026-11-05T00:14:33.917Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dfdec00c876c4ccdae3c51b3e1f7129f/download","mirrored":false},{"resource_id":"fce44ccd7d284764aaab7b95b2f6f0be","name":"36C24627B0001.docx","kind":"file","mime_type":".docx","size_bytes":277133,"posted_at":"2026-11-05T00:14:33.917Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fce44ccd7d284764aaab7b95b2f6f0be/download","mirrored":false},{"resource_id":"5f10e13588614e73b8d6093cc7ecfab1","name":"565-22-500 Combined Set 20251118.pdf","kind":"file","mime_type":".pdf","size_bytes":43575149,"posted_at":"2026-11-05T13:39:42.298Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5f10e13588614e73b8d6093cc7ecfab1/download","mirrored":false},{"resource_id":"8ff54057e139402585d40ec514aa1bee","name":"Sign-in sheet_12Nov2026.pdf","kind":"file","mime_type":".pdf","size_bytes":718462,"posted_at":"2026-11-20T01:46:58.090Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8ff54057e139402585d40ec514aa1bee/download","mirrored":false},{"resource_id":"b848945ab6194678aede92163661b877","name":"19-Outage Plan.pdf","kind":"file","mime_type":".pdf","size_bytes":236798,"posted_at":"2026-11-20T01:46:58.090Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b848945ab6194678aede92163661b877/download","mirrored":false},{"resource_id":"d068bd5f90c04a8a990540fa9cfd62ae","name":"18-Hazmat Survey.pdf","kind":"file","mime_type":".pdf","size_bytes":4919580,"posted_at":"2026-11-20T01:46:58.090Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d068bd5f90c04a8a990540fa9cfd62ae/download","mirrored":false},{"resource_id":"d238f1c2560b4e4dbd684c845928ac7d","name":"21-21 Nov 2014 VACO ECA E24.pdf","kind":"file","mime_type":".pdf","size_bytes":4357088,"posted_at":"2026-11-20T01:46:58.090Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d238f1c2560b4e4dbd684c845928ac7d/download","mirrored":false}],"awards":[],"related":[{"key":"36C24627Q0114","latest_notice_id":"9464cbfda7004348805568dfa367e88c","title":"5975--INSTALLATION OF PROXIMITY SENSORS FOR AUTOMATIC DOORS","solicitation_number":"36C24627Q0114","notice_type":"o","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238210","psc":"5975","set_aside":null,"state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":"Product purchase (PSC 5975)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24627Q0089","latest_notice_id":"ae159e2fd01a497898d98fab5ce61da1","title":"Q301-- FISH TECH Testing","solicitation_number":"36C24627Q0089","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"621511","psc":"Q301","set_aside":null,"state":"VA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"RACT AWARD. FOR LABORATORY SAMPLES, RICHMOND VAMC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24627Q0113","latest_notice_id":"dd890cb683014f54b3c473a4fac2948f","title":"7230--WINDOW TREATMENT","solicitation_number":"36C24627Q0113","notice_type":"o","first_type":"p","first_posted":"2026-11-06","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"337920","psc":"7230","set_aside":"SBA","state":"VA","county":"51650","county_name":"City of Hampton","city":"5135000","city_name":"Hampton","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":"Product purchase (PSC 7230)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24627Q0149","latest_notice_id":"0f55c0d6fb1b4b4c8be2a3cdcb19cfc5","title":"5670--Dumpster Area Roll Up Door Replacement","solicitation_number":"36C24627Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24627Q0153","latest_notice_id":"4d24e9c5db104196af7772b612e1b14c","title":"8470-- Police Ballistic Vests","solicitation_number":"36C24627Q0153","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"315990","psc":"8470","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"N4008527R9000","latest_notice_id":"e4744972f4e84b3286e6e79ef5250186","title":"Repair Auto Maintenance Facility Bldg 575 (230040)","solicitation_number":"N4008527R9000","notice_type":"k","first_type":"k","first_posted":"2026-10-22","last_posted":"2026-11-18","notices":9,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2EB","set_aside":"SBA","state":"NC","county":"37133","county_name":"Onslow County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24626B0041","latest_notice_id":"386b9ba47ba540ba974b1f3ac521e4de","title":"Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009)","solicitation_number":"36C24626B0041","notice_type":"p","first_type":"p","first_posted":"2026-09-18","last_posted":"2026-10-23","notices":2,"due_at":"2026-12-03T02:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T02:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"A HEALTH CARE CENTER, 508 FULTON ST, DURHAM, NC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"},{"key":"N4008527R9006","latest_notice_id":"fb648b5b7455433fb4b126c28e4d2b14","title":"NH100 Engine Control Unit Replacement","solicitation_number":"N4008527R9006","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-20","notices":4,"due_at":"2026-12-04T18:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2DA","set_aside":"SBA","state":"NC","county":"37133","county_name":"Onslow County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":193,"indexable":true}