{"canonical":"https://sealedbidder.com/opportunities/36c24626q0564","key":"36C24626Q0564","url":"https://sealedbidder.com/opportunities/36c24626q0564","title":"5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS","solicitation_number":"36C24626Q0564","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-07T19:00:00Z","first_posted":"2026-04-29","last_posted":"2026-04-29","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"place_state":"NC","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"37051","place_county_name":"Cumberland County","place_city":"3722920","place_city_name":"Fayetteville","winner":null,"award_amount":null,"publications":[{"notice_id":"5e4adde126f642d3a3e109e12a486320","title":"5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS","solicitation_number":"36C24626Q0564","notice_type":"r","base_type":"r","posted":"2026-04-29","posted_at":"2026-04-29T14:48:52.713Z","due_at":"2026-05-07T19:00:00Z","due_date":"2026-05-07","cancelled":false,"archived":true,"archive_date":"2026-06-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5e4adde126f642d3a3e109e12a486320/view","enriched":true,"history":[{"index":3,"title":"5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-29T14:48:52.713Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5e4adde126f642d3a3e109e12a486320","solicitation_number":"36C24626Q0564"}]}],"latest_notice_id":"5e4adde126f642d3a3e109e12a486320","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-04-29","posted_at":"2026-04-29T14:48:52.713Z","created_at":"2026-04-29T14:48:49.332Z","modified_at":"2026-06-06T04:04:26.524Z","response_deadline":{"raw":"2026-05-07T15:00:00-04:00","utc":"2026-05-07T19:00:00Z","date":"2026-05-07","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5e4adde126f642d3a3e109e12a486320/view"},"naics":{"codes":["332321"],"primary":"332321"},"title":"5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_id":"100167096","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"5670--REPLACING 2 BARRIER RESISTANT DOORS FOR MENTAL HEALKTH PATIENTS ROOMS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-29T14:48:52.713Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5e4adde126f642d3a3e109e12a486320","solicitation_number":"36C24626Q0564"}],"contacts":[{"name":"jake.puckett@va.gov","role":"primary","email":"Jake.Puckett@va.gov","title":"Jake Puckett"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"5e4adde126f642d3a3e109e12a486320","lineage_id":"5e4adde126f642d3a3e109e12a486320","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T13:07:45.565673371Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6705765b60d2e168a4d9a0ab6a5b396a9eab70891f1f4a11141e52502658b266","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T13:07:45.565673371Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of the Fayetteville VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses capable of providing two (2) replacement doors for mental health patients  rooms:\nThe contractor shall furnish labor, parts, supplies and equipment necessary to provide and install new 2 Acrovyn Barrier Resistant Doors.\nThe contractor is required to conduct a site visit to gain a complete understanding of the work and requirements that need to be accomplished.\nServices should be performed in accordance with terms and conditions in this statement of work and be in compliance with all manufacturers  technical specifications.\nThe estimate dimensions of the existing door: (Width: 43-1/2  Height: 83-1/4  Thickness: 1-3/4 )\nKey Door Requirements for Behavioral Health\nLigature Resistance:Â All hardware, including handles, hinges, and closures, must be designed to minimize ligature points.\nAnti-Barricade/Access:Â Doors often feature double-swing hinges or emergency release stops, allowing them to swing outward into the hallway even if they normally swing inward, enabling staff to overcome barricades.\nSafety Features:Â Use of concealed hinges, continuous gear hinges.\nMonitoring & Security:Â Doors usually include door-top sensors that alert staff to self-harm attempts.\nDoor Types:Â Options include \"door within a door\" (wicket) allowing a smaller portion of the door to open for emergency access.\nMaterial:Â Doors are typically constructed from high-strength materials like fully welded, hollow metal steel frames.\nCompliance and Standards\nNFPA 101-2012:Â Provides standards on door-locking arrangements in psychiatric units.\nJoint Commission:Â \nRequires compliance with 2021 Behavioral Health standards, including specific requirements for door gaps (not exceeding 1/8 inch) and undercuts (not exceeding 1 inch) to ensure security and smoke resistance.Â \nUL (Underwriters Laboratories) Standards: UL 10C for fire door assemblies, ensuring fire resistance and integrity.\nNFPA (National Fire Protection Association): NFPA 80 for fire door assemblies and opening protectives.\nANSI (American National Standards Institute): ANSI/UL 263 for fire resistance testing.\nASTM (American Society for Testing and Materials): Standards related to material performance, such as ASTM E119 for fire testing.\nISO Standards: ISO 300-2007 for fire resistance of building elements, depending on project requirements.\nLocal Building Codes: Compliance with local and national building codes, which may specify performance and safety standards.\n\n\n\n\nAll respondents shall indicate/provide the following:\nWhether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.\nIs your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?\nWhether or not your company has an active SAM registration and the companies Unique Entity Identifier.\nA copy of its capabilities statement.\nFailure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.\nIf the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered  grey market  and shall not be considered capable of meeting the VA s needs.\nThe capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses.  All responses shall be submitted in writing no later than May 7th, at 3:00PM EST to the attention of:  jake.puckett@va.gov \nAll responses shall be submitted as: Sources Sought 36C24626Q0564: Fayetteville VAMC Replacement Doors for Mental Health Patient Rooms.","text":"The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of the Fayetteville VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses capable of providing two (2) replacement doors for mental health patients rooms:\nThe contractor shall furnish labor, parts, supplies and equipment necessary to provide and install new 2 Acrovyn Barrier Resistant Doors.\nThe contractor is required to conduct a site visit to gain a complete understanding of the work and requirements that need to be accomplished.\nServices should be performed in accordance with terms and conditions in this statement of work and be in compliance with all manufacturers technical specifications.\nThe estimate dimensions of the existing door: (Width: 43-1/2 Height: 83-1/4 Thickness: 1-3/4 )\nKey Door Requirements for Behavioral Health\nLigature Resistance:Â All hardware, including handles, hinges, and closures, must be designed to minimize ligature points.\nAnti-Barricade/Access:Â Doors often feature double-swing hinges or emergency release stops, allowing them to swing outward into the hallway even if they normally swing inward, enabling staff to overcome barricades.\nSafety Features:Â Use of concealed hinges, continuous gear hinges.\nMonitoring & Security:Â Doors usually include door-top sensors that alert staff to self-harm attempts.\nDoor Types:Â Options include \"door within a door\" (wicket) allowing a smaller portion of the door to open for emergency access.\nMaterial:Â Doors are typically constructed from high-strength materials like fully welded, hollow metal steel frames.\nCompliance and Standards\nNFPA 101-2012:Â Provides standards on door-locking arrangements in psychiatric units.\nJoint Commission:Â\nRequires compliance with 2021 Behavioral Health standards, including specific requirements for door gaps (not exceeding 1/8 inch) and undercuts (not exceeding 1 inch) to ensure security and smoke resistance.Â\nUL (Underwriters Laboratories) Standards: UL 10C for fire door assemblies, ensuring fire resistance and integrity.\nNFPA (National Fire Protection Association): NFPA 80 for fire door assemblies and opening protectives.\nANSI (American National Standards Institute): ANSI/UL 263 for fire resistance testing.\nASTM (American Society for Testing and Materials): Standards related to material performance, such as ASTM E119 for fire testing.\nISO Standards: ISO 300-2007 for fire resistance of building elements, depending on project requirements.\nLocal Building Codes: Compliance with local and national building codes, which may specify performance and safety standards.\n\nAll respondents shall indicate/provide the following:\nWhether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.\nIs your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?\nWhether or not your company has an active SAM registration and the companies Unique Entity Identifier.\nA copy of its capabilities statement.\nFailure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.\nIf the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered capable of meeting the VA s needs.\nThe capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than May 7th, at 3:00PM EST to the attention of: jake.puckett@va.gov\nAll responses shall be submitted as: Sources Sought 36C24626Q0564: Fayetteville VAMC Replacement Doors for Mental Health Patient Rooms.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24626Q0564","place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"street":"Fayetteville VAMC 2300 Ramsey ST","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5670"}],"due_at":"2026-05-07T19:00:00Z","due_date":"2026-05-07","closes_at":"2026-05-07T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-05T13:12:22.352488Z","principal_notice_id":"5e4adde126f642d3a3e109e12a486320","description":{"text":"The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of the Fayetteville VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses capable of providing two (2) replacement doors for mental health patients rooms:\nThe contractor shall furnish labor, parts, supplies and equipment necessary to provide and install new 2 Acrovyn Barrier Resistant Doors.\nThe contractor is required to conduct a site visit to gain a complete understanding of the work and requirements that need to be accomplished.\nServices should be performed in accordance with terms and conditions in this statement of work and be in compliance with all manufacturers technical specifications.\nThe estimate dimensions of the existing door: (Width: 43-1/2 Height: 83-1/4 Thickness: 1-3/4 )\nKey Door Requirements for Behavioral Health\nLigature Resistance:Â All hardware, including handles, hinges, and closures, must be designed to minimize ligature points.\nAnti-Barricade/Access:Â Doors often feature double-swing hinges or emergency release stops, allowing them to swing outward into the hallway even if they normally swing inward, enabling staff to overcome barricades.\nSafety Features:Â Use of concealed hinges, continuous gear hinges.\nMonitoring & Security:Â Doors usually include door-top sensors that alert staff to self-harm attempts.\nDoor Types:Â Options include \"door within a door\" (wicket) allowing a smaller portion of the door to open for emergency access.\nMaterial:Â Doors are typically constructed from high-strength materials like fully welded, hollow metal steel frames.\nCompliance and Standards\nNFPA 101-2012:Â Provides standards on door-locking arrangements in psychiatric units.\nJoint Commission:Â\nRequires compliance with 2021 Behavioral Health standards, including specific requirements for door gaps (not exceeding 1/8 inch) and undercuts (not exceeding 1 inch) to ensure security and smoke resistance.Â\nUL (Underwriters Laboratories) Standards: UL 10C for fire door assemblies, ensuring fire resistance and integrity.\nNFPA (National Fire Protection Association): NFPA 80 for fire door assemblies and opening protectives.\nANSI (American National Standards Institute): ANSI/UL 263 for fire resistance testing.\nASTM (American Society for Testing and Materials): Standards related to material performance, such as ASTM E119 for fire testing.\nISO Standards: ISO 300-2007 for fire resistance of building elements, depending on project requirements.\nLocal Building Codes: Compliance with local and national building codes, which may specify performance and safety standards.\n\nAll respondents shall indicate/provide the following:\nWhether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.\nIs your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?\nWhether or not your company has an active SAM registration and the companies Unique Entity Identifier.\nA copy of its capabilities statement.\nFailure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.\nIf the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered capable of meeting the VA s needs.\nThe capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than May 7th, at 3:00PM EST to the attention of: jake.puckett@va.gov\nAll responses shall be submitted as: Sources Sought 36C24626Q0564: Fayetteville VAMC Replacement Doors for Mental Health Patient Rooms.","html":"The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of the Fayetteville VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses capable of providing two (2) replacement doors for mental health patients  rooms:\nThe contractor shall furnish labor, parts, supplies and equipment necessary to provide and install new 2 Acrovyn Barrier Resistant Doors.\nThe contractor is required to conduct a site visit to gain a complete understanding of the work and requirements that need to be accomplished.\nServices should be performed in accordance with terms and conditions in this statement of work and be in compliance with all manufacturers  technical specifications.\nThe estimate dimensions of the existing door: (Width: 43-1/2  Height: 83-1/4  Thickness: 1-3/4 )\nKey Door Requirements for Behavioral Health\nLigature Resistance:Â All hardware, including handles, hinges, and closures, must be designed to minimize ligature points.\nAnti-Barricade/Access:Â Doors often feature double-swing hinges or emergency release stops, allowing them to swing outward into the hallway even if they normally swing inward, enabling staff to overcome barricades.\nSafety Features:Â Use of concealed hinges, continuous gear hinges.\nMonitoring & Security:Â Doors usually include door-top sensors that alert staff to self-harm attempts.\nDoor Types:Â Options include \"door within a door\" (wicket) allowing a smaller portion of the door to open for emergency access.\nMaterial:Â Doors are typically constructed from high-strength materials like fully welded, hollow metal steel frames.\nCompliance and Standards\nNFPA 101-2012:Â Provides standards on door-locking arrangements in psychiatric units.\nJoint Commission:Â \nRequires compliance with 2021 Behavioral Health standards, including specific requirements for door gaps (not exceeding 1/8 inch) and undercuts (not exceeding 1 inch) to ensure security and smoke resistance.Â \nUL (Underwriters Laboratories) Standards: UL 10C for fire door assemblies, ensuring fire resistance and integrity.\nNFPA (National Fire Protection Association): NFPA 80 for fire door assemblies and opening protectives.\nANSI (American National Standards Institute): ANSI/UL 263 for fire resistance testing.\nASTM (American Society for Testing and Materials): Standards related to material performance, such as ASTM E119 for fire testing.\nISO Standards: ISO 300-2007 for fire resistance of building elements, depending on project requirements.\nLocal Building Codes: Compliance with local and national building codes, which may specify performance and safety standards.\n\n\n\n\nAll respondents shall indicate/provide the following:\nWhether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer.\nIs your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?\nWhether or not your company has an active SAM registration and the companies Unique Entity Identifier.\nA copy of its capabilities statement.\nFailure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.\nIf the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered  grey market  and shall not be considered capable of meeting the VA s needs.\nThe capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses.  All responses shall be submitted in writing no later than May 7th, at 3:00PM EST to the attention of:  jake.puckett@va.gov \nAll responses shall be submitted as: Sources Sought 36C24626Q0564: Fayetteville VAMC Replacement Doors for Mental Health Patient Rooms.","origin":"detail"},"contacts":[{"name":"jake.puckett@va.gov","role":"primary","email":"Jake.Puckett@va.gov","title":"Jake Puckett"}],"place_of_performance":{"zip":"28301","city":{"code":"22920","name":"Fayetteville"},"state":{"code":"NC","name":"North Carolina"},"street":"Fayetteville VAMC 2300 Ramsey ST","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"naics_codes":["332321"],"award":{"awardee":{}},"attachments":[{"resource_id":"3c757736ed8d42b9a4822cdb00c55582","name":"36C24626Q0564.docx","kind":"file","mime_type":".docx","size_bytes":403469,"posted_at":"2026-04-29T14:48:52.713Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3c757736ed8d42b9a4822cdb00c55582/download","mirrored":false}],"awards":[],"related":[{"key":"36C24627Q0149","latest_notice_id":"0f55c0d6fb1b4b4c8be2a3cdcb19cfc5","title":"5670--Dumpster Area Roll Up Door Replacement","solicitation_number":"36C24627Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24627Q0153","latest_notice_id":"4d24e9c5db104196af7772b612e1b14c","title":"8470-- Police Ballistic Vests","solicitation_number":"36C24627Q0153","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"315990","psc":"8470","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24626Q10991","latest_notice_id":"8689b6e16d9540bb8e955fa0fe26acb8","title":"LOADING DOCK CONCRETE REPAIRS","solicitation_number":"36C24626Q1099_1","notice_type":"o","first_type":"o","first_posted":"2026-10-23","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238110","psc":"Z1DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24627R0011","latest_notice_id":"3d14d2e074b241d98dbfed766bfdb01a","title":"Z2DA--652-23-109 Renovate SPS Phase 3","solicitation_number":"36C24627R0011","notice_type":"p","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24626B0041","latest_notice_id":"386b9ba47ba540ba974b1f3ac521e4de","title":"Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009)","solicitation_number":"36C24626B0041","notice_type":"p","first_type":"p","first_posted":"2026-09-18","last_posted":"2026-10-23","notices":2,"due_at":"2026-12-03T02:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T02:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"A HEALTH CARE CENTER, 508 FULTON ST, DURHAM, NC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open":[{"key":"36C24627Q0149","latest_notice_id":"0f55c0d6fb1b4b4c8be2a3cdcb19cfc5","title":"5670--Dumpster Area Roll Up Door Replacement","solicitation_number":"36C24627Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"SPE4A727T4493","latest_notice_id":"e97714f7cc594cfea7daaa123b07f404","title":"53--BOLT,SHEAR","solicitation_number":"SPE4A727T4493","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A7","office_name":"DLA AVIATION","naics":"332321","psc":"53","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"HEAR: LINE 0001 QTY 138 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"N0040627Q0017","latest_notice_id":"7ed39b1305fa4fc69101ccc164e8fcdd","title":"Sole Source to Jered LLC - Hanger Door Replacement Parts","solicitation_number":"N0040627Q0017","notice_type":"o","first_type":"o","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-01T22:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00406","office_name":"NAVSUP FLT LOG CTR PUGET SOUND","naics":"332321","psc":"5305","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 5305)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":8,"indexable":false}