{"canonical":"https://sealedbidder.com/opportunities/36c24626q0335","key":"36C24626Q0335","url":"https://sealedbidder.com/opportunities/36c24626q0335","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-24T14:00:00Z","first_posted":"2026-02-09","last_posted":"2026-03-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"333310","psc":"4610","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":"Hampton VA Medical Center","place_state_source":null,"place_evidence":"Product purchase (PSC 4610)","place_county":"42003","place_county_name":"Allegheny County","place_city":"4261000","place_city_name":"Pittsburgh","winner":"EVOQUA WATER TECHNOLOGIES LLC","award_amount":null,"publications":[{"notice_id":"fd16752ac47f4f01b09800caf95aec3c","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","base_type":"r","posted":"2026-02-09","posted_at":"2026-02-09T15:00:41.513Z","due_at":"2026-02-17T15:00:00Z","due_date":"2026-02-17","cancelled":false,"archived":true,"archive_date":"2026-03-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fd16752ac47f4f01b09800caf95aec3c/view","enriched":true,"history":[{"index":3,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T16:08:38.678Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"60d5c179b2a4412e93c8a6f486e7a963","solicitation_number":"36C24626Q0335","parent_opportunity_id":"fd16752ac47f4f01b09800caf95aec3c"},{"index":1,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-09T15:00:41.513Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fd16752ac47f4f01b09800caf95aec3c","solicitation_number":"36C24626Q0335"}]},{"notice_id":"60d5c179b2a4412e93c8a6f486e7a963","title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","solicitation_number":"36C24626Q0335","notice_type":"r","base_type":"r","posted":"2026-03-18","posted_at":"2026-03-18T16:08:38.678Z","due_at":"2026-03-24T14:00:00Z","due_date":"2026-03-24","cancelled":false,"archived":true,"archive_date":"2026-04-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/60d5c179b2a4412e93c8a6f486e7a963/view","enriched":true,"history":[{"index":3,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T16:08:38.678Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"60d5c179b2a4412e93c8a6f486e7a963","solicitation_number":"36C24626Q0335","parent_opportunity_id":"fd16752ac47f4f01b09800caf95aec3c"},{"index":1,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-09T15:00:41.513Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fd16752ac47f4f01b09800caf95aec3c","solicitation_number":"36C24626Q0335"}]}],"latest_notice_id":"60d5c179b2a4412e93c8a6f486e7a963","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-02-09","posted_at":"2026-02-09T15:00:41.513Z","created_at":"2026-02-09T15:00:39.292Z","modified_at":"2026-04-24T04:04:28.877Z","response_deadline":{"raw":"2026-02-17T10:00:00-05:00","utc":"2026-02-17T15:00:00Z","date":"2026-02-17","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fd16752ac47f4f01b09800caf95aec3c/view"},"naics":{"codes":["333310"],"primary":"333310"},"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_id":"100167096","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-19","archive_type":"auto_custom"},"history":[{"index":3,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T16:08:38.678Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"60d5c179b2a4412e93c8a6f486e7a963","solicitation_number":"36C24626Q0335","parent_opportunity_id":"fd16752ac47f4f01b09800caf95aec3c"},{"index":1,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-09T15:00:41.513Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fd16752ac47f4f01b09800caf95aec3c","solicitation_number":"36C24626Q0335"}],"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"fd16752ac47f4f01b09800caf95aec3c","lineage_id":"fd16752ac47f4f01b09800caf95aec3c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T01:13:46.036074393Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6871d8c18f5ce32d30c06123b5ee778ec6331fd43b951595bebd75226cbc0af4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T01:13:46.036074393Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate   maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2)\n- Particles 0.2  m filter Silica <0.05 mg/l\n- Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures\n- Feedwater Requirement:\n- Source: Tap water as detailed below Conductivity: <1000  S/cm\n- Contaminant:\n- Measure: Range: Pretreatment:\n- Calcium: Ca ppm as CaCO3 <250 None3\n- >250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm <0.1 None\n- 0.1   0.5 20 inch carbon block\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Chloramine: Cl2 ppm <0.1 None\n- 0.1   0.5 20 inch high efficiency carbon (5)\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Silica: SiO2 ppm <30 None\n- >30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI <10 None\n- 10 to 20 20 inch cartridge depth filter\n- >20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm <0.05 None\n- >0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C <2 None\n- 2 to 3 20 inch carbon block (4)\n- >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","text":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical 250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24626Q0335","product_service_code":"4610"},{"award":{"awardee":{}},"dates":{"posted":"2026-03-18","posted_at":"2026-03-18T16:08:38.678Z","created_at":"2026-03-18T15:19:17.281Z","modified_at":"2026-04-24T04:04:28.877Z","response_deadline":{"raw":"2026-03-24T10:00:00-04:00","utc":"2026-03-24T14:00:00Z","date":"2026-03-24","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/60d5c179b2a4412e93c8a6f486e7a963/view"},"naics":{"codes":["333310"],"primary":"333310"},"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_id":"100167096","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-24","archive_type":"auto_custom"},"history":[{"index":3,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-18T16:08:38.678Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"60d5c179b2a4412e93c8a6f486e7a963","solicitation_number":"36C24626Q0335","parent_opportunity_id":"fd16752ac47f4f01b09800caf95aec3c"},{"index":1,"title":"4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-09T15:00:41.513Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fd16752ac47f4f01b09800caf95aec3c","solicitation_number":"36C24626Q0335"}],"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"60d5c179b2a4412e93c8a6f486e7a963","lineage_id":"fd16752ac47f4f01b09800caf95aec3c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T01:30:55.995638685Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"5c79ae1fe4482c711c7b6da81b847e4d0f6516e65982bc43fa28aa6722eaf99d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T01:30:55.995638685Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate   maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2)\n- Particles 0.2  m filter Silica <0.05 mg/l\n- Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures\n- Feedwater Requirement:\n- Source: Tap water as detailed below Conductivity: <1000  S/cm\n- Contaminant:\n- Measure: Range: Pretreatment:\n- Calcium: Ca ppm as CaCO3 <250 None3\n- >250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm <0.1 None\n- 0.1   0.5 20 inch carbon block\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Chloramine: Cl2 ppm <0.1 None\n- 0.1   0.5 20 inch high efficiency carbon (5)\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Silica: SiO2 ppm <30 None\n- >30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI <10 None\n- 10 to 20 20 inch cartridge depth filter\n- >20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm <0.05 None\n- >0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C <2 None\n- 2 to 3 20 inch carbon block (4)\n- >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","text":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical 250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24626Q0335","product_service_code":"4610"}],"due_at":"2026-03-24T14:00:00Z","due_date":"2026-03-24","closes_at":"2026-03-24T14:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":null,"state_source":null,"state_evidence":"Product purchase (PSC 4610)","site_key":"hampton-va-medical-center-va","winner_key":"HA3GWLK3JK58","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-11T01:44:22.489590Z","principal_notice_id":"60d5c179b2a4412e93c8a6f486e7a963","description":{"text":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical 250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C 3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","html":"VAMC Hampton is looking for a Water Purification system with the following:\n- Salient Characteristics\n- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities\n- MODEL MEDICA-R 200\n- Make-up rate 15C 200 l/hr\n- Delivery flow rate   maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25Â°C) >10 M -cm (1)\n- Organics (TOC) - typical <30ppb -500 PPB (1) Bacteria - typical <10 CFU/ml (2)\n- Particles 0.2  m filter Silica <0.05 mg/l\n- Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures\n- Feedwater Requirement:\n- Source: Tap water as detailed below Conductivity: <1000  S/cm\n- Contaminant:\n- Measure: Range: Pretreatment:\n- Calcium: Ca ppm as CaCO3 <250 None3\n- >250 Softener or use very low RO recovery3\n- Free chlorine: Cl2ppm <0.1 None\n- 0.1   0.5 20 inch carbon block\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Chloramine: Cl2 ppm <0.1 None\n- 0.1   0.5 20 inch high efficiency carbon (5)\n- >0.5 Cylinder of carbon sized correctly to obtain <0.1 ppm\n- Silica: SiO2 ppm <30 None\n- >30 20 inch cartridge depth filter or use very low RO recovery (4)\n- Fouling index: FI <10 None\n- 10 to 20 20 inch cartridge depth filter\n- >20 Back washable media filter with a minimum flow rate of 20 l/min\n- Iron/manganese: Fe/Mn ppm <0.05 None\n- >0.05 20 inch cartridge depth filter (5)\n- >0.1 Back-washable Fe filter (6)\n- Organics: TOC ppm C <2 None\n- 2 to 3 20 inch carbon block (4)\n- >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40Â°C (Recommended 15 - 25Â°C)\n-- Flowrate: (requirement at 15Â°C) 20 l/min\n- Drain requirements: (gravity fall with air gap) 45 l/min\n- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum\n- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,\n- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)\n- Must include Installation, Commissioning, Training\n- Electrical Requirements Mains Input: 115V, 60Hz\n- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA\n- Electrical protection rating 20 amps Noise level during recirculation <70dBA\n- ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.\n- -The floor drain must be a minimum of 3\" and meet all applicable building codes and system requirements\n- -Actual Unit measurement 32\" Wide x35\"Deep x72\"High","origin":"detail"},"contacts":[{"name":"John P Harmsen","role":"primary","email":"john.harmsen@va.gov","phone":"757-722-7961","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"naics_codes":["333310"],"award":{"awardee":{}},"attachments":[{"resource_id":"305b2f9e066c4b63b537967988090fe0","name":"36C24626Q0335.docx","kind":"file","mime_type":".docx","size_bytes":15761,"posted_at":"2026-02-09T15:00:41.513Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/305b2f9e066c4b63b537967988090fe0/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24626P0550_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24626P0550_3600_-NONE-_-NONE-/","piid":"36C24626P0550","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"HA3GWLK3JK58","recipient_name":"EVOQUA WATER TECHNOLOGIES LLC","recipient_uei":"HA3GWLK3JK58","recipient_cage":"72XB4","recipient_city":"PITTSBURGH","recipient_state":"PA","sub_name":"Department of Veterans Affairs","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","office_key":"o-36C246","first_action_date":"2026-03-31","last_action_date":"2026-04-09","actions":2,"obligated":"0","current_total_value":"0","potential_total_value":"0","naics":"333310","psc":"6515","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"DIALYSIS WATER SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24626Q0335 equals the FPDS solicitation identifier","same awarding office 36C246"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24627Q0149","latest_notice_id":"0f55c0d6fb1b4b4c8be2a3cdcb19cfc5","title":"5670--Dumpster Area Roll Up Door Replacement","solicitation_number":"36C24627Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24627Q0153","latest_notice_id":"4d24e9c5db104196af7772b612e1b14c","title":"8470-- Police Ballistic Vests","solicitation_number":"36C24627Q0153","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"315990","psc":"8470","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24626Q10991","latest_notice_id":"8689b6e16d9540bb8e955fa0fe26acb8","title":"LOADING DOCK CONCRETE REPAIRS","solicitation_number":"36C24626Q1099_1","notice_type":"o","first_type":"o","first_posted":"2026-10-23","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238110","psc":"Z1DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24627R0011","latest_notice_id":"3d14d2e074b241d98dbfed766bfdb01a","title":"Z2DA--652-23-109 Renovate SPS Phase 3","solicitation_number":"36C24627R0011","notice_type":"p","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24626B0041","latest_notice_id":"386b9ba47ba540ba974b1f3ac521e4de","title":"Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009)","solicitation_number":"36C24626B0041","notice_type":"p","first_type":"p","first_posted":"2026-09-18","last_posted":"2026-10-23","notices":2,"due_at":"2026-12-03T02:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T02:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"A HEALTH CARE CENTER, 508 FULTON ST, DURHAM, NC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open":[{"key":"SPRBL126RA001","latest_notice_id":"38eea2c7fc6d49808c1d604b65232896","title":"AFOCAL Lens","solicitation_number":"SPRBL126RA001","notice_type":"o","first_type":"p","first_posted":"2026-07-22","last_posted":"2026-11-02","notices":6,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"333310","psc":"6650","set_aside":null,"state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-03T04:52:39.433634Z"},{"key":"SPE8E827Q0069","latest_notice_id":"e57ede98194b432198c49945f413c287","title":"46--FEEDER,CHEMICAL SOLUTI","solicitation_number":"SPE8E827Q0069","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE8E8","office_name":"DLA TROOP SUPPORT","naics":"333310","psc":"46","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SOLUTI: LINE 0001 QTY 1 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W911S227U0181","latest_notice_id":"8e74fb773b7b41c5aaa21254f2e36ffe","title":"Industrial Pressing Equipment","solicitation_number":"W911S227U0181","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T04:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T04:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"333310","psc":"3510","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"687 ROGERS PLACE WEST POINT, NY 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":60,"indexable":false}