{"canonical":"https://sealedbidder.com/opportunities/36c24626b0039","key":"36C24626B0039","url":"https://sealedbidder.com/opportunities/36c24626b0039","title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","solicitation_number":"36C24626B0039","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-08T14:00:00Z","first_posted":"2026-07-21","last_posted":"2026-08-31","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238220","psc":"Z2NZ","set_aside":"SDVOSBC","place_state":"NC","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"37159","place_county_name":"Rowan County","place_city":"3758860","place_city_name":"Salisbury","winner":null,"award_amount":null,"publications":[{"notice_id":"dd7b009e8ae84c3fbff15448458150df","title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","solicitation_number":"36C24626B0039","notice_type":"p","base_type":"p","posted":"2026-07-21","posted_at":"2026-07-21T17:53:02.367Z","due_at":"2026-09-08T14:00:00Z","due_date":"2026-09-08","cancelled":null,"archived":null,"archive_date":"2026-12-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dd7b009e8ae84c3fbff15448458150df/view","enriched":true,"history":[{"index":3,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T16:10:11.767Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"caf740c01f5f435aac510a0436d41d00","solicitation_number":"36C24626B0039","parent_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":2,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-05T20:02:36.839Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"40bc859fb9e74b36b3aaaaca76d466e9","solicitation_number":"36C24626B0039_1_","related_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":1,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-21T17:53:02.367Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"dd7b009e8ae84c3fbff15448458150df","solicitation_number":"36C24626B0039"}]},{"notice_id":"caf740c01f5f435aac510a0436d41d00","title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","solicitation_number":"36C24626B0039","notice_type":"p","base_type":"p","posted":"2026-08-31","posted_at":"2026-08-31T16:10:11.767Z","due_at":"2026-09-08T14:00:00Z","due_date":"2026-09-08","cancelled":null,"archived":null,"archive_date":"2026-12-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/caf740c01f5f435aac510a0436d41d00/view","enriched":true,"history":[{"index":2,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T16:10:11.767Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"caf740c01f5f435aac510a0436d41d00","solicitation_number":"36C24626B0039","parent_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":1,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-21T17:53:02.367Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"dd7b009e8ae84c3fbff15448458150df","solicitation_number":"36C24626B0039"}]}],"latest_notice_id":"caf740c01f5f435aac510a0436d41d00","first_type":"p","notices":[{"dates":{"posted":"2026-07-21","posted_at":"2026-07-21T17:53:02.367Z","created_at":"2026-07-21T17:53:00.101Z","modified_at":"2026-08-31T16:10:11.767Z","response_deadline":{"raw":"2026-09-08T10:00:00-04:00","utc":"2026-09-08T14:00:00Z","date":"2026-09-08","time":"10:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dd7b009e8ae84c3fbff15448458150df/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-12-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T16:10:11.767Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"caf740c01f5f435aac510a0436d41d00","solicitation_number":"36C24626B0039","parent_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":2,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-05T20:02:36.839Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"40bc859fb9e74b36b3aaaaca76d466e9","solicitation_number":"36C24626B0039_1_","related_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":1,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-21T17:53:02.367Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"dd7b009e8ae84c3fbff15448458150df","solicitation_number":"36C24626B0039"}],"contacts":[{"name":"Mark Griffin","role":"primary","email":"mark.griffin2@va.gov","phone":"704-638-9000 13630","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"dd7b009e8ae84c3fbff15448458150df","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"dd7b009e8ae84c3fbff15448458150df","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T02:20:58.893804184Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"bbc6259bb61d29a8ebc5173ef8da2755ed9c4f2a20d280efc4451f56ef67981d","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus \nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:  \nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items. \n\nBackground Information: \nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31. \n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\n  Building 42 and Building 43 are served directly from building 31 chilled-water plant.\n  The existing chillers for 42 and 43 are isolated and not in use.\n  Valves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\n  Building 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\n  Building 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\n  Install additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\n  Run new 4\" chilled-water supply and return lines from Building 31 to Building 43.\n  Provide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\n  All new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01   General Requirements \nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete \nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify  T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications \nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32   Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23   Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26   Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27   Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings: \n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.) \n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.) \n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00) \n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.) \n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.) \n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.) \n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.) \n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.) \nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES   regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES   on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES   periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES   travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.) \n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements) \n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.) \nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000. \nNAICS Code 238220 \nSize Standard Table: $19 Million \nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov. \nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","text":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus\nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:\nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items.\n\nBackground Information:\nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31.\n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\nBuilding 42 and Building 43 are served directly from building 31 chilled-water plant.\nThe existing chillers for 42 and 43 are isolated and not in use.\nValves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\nBuilding 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\nBuilding 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\nInstall additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\nRun new 4\" chilled-water supply and return lines from Building 31 to Building 43.\nProvide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\nAll new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01 General Requirements\nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete\nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications\nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32 Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23 Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26 Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27 Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings:\n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.)\n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.)\n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00)\n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.)\n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.)\n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.)\n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.)\n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.)\nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.)\n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements)\n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.)\nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000.\nNAICS Code 238220\nSize Standard Table: $19 Million\nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov.\nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24626B0039","place_of_performance":{"zip":"28144","city":{"name":"Salisbury"},"state":{"code":"NC"},"street":"W.G. Hefner VAMC 1601 Brenner Ave.","country":{"code":"USA"}},"product_service_code":"Z2NZ"},{"dates":{"posted":"2026-08-31","posted_at":"2026-08-31T16:10:11.767Z","created_at":"2026-08-05T19:53:21.342Z","modified_at":"2026-08-31T16:10:11.842Z","response_deadline":{"raw":"2026-09-08T10:00:00-04:00","utc":"2026-09-08T14:00:00Z","date":"2026-09-08","time":"10:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/caf740c01f5f435aac510a0436d41d00/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","agency":{"office":{"code":"36C246","name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-12-16","archive_type":"auto_custom"},"history":[{"index":2,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-31T16:10:11.767Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"caf740c01f5f435aac510a0436d41d00","solicitation_number":"36C24626B0039","parent_opportunity_id":"dd7b009e8ae84c3fbff15448458150df"},{"index":1,"title":"Z2NZ--659-24-203: Extend Chilled Water to Hospice and Audiology","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-21T17:53:02.367Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"dd7b009e8ae84c3fbff15448458150df","solicitation_number":"36C24626B0039"}],"contacts":[{"name":"Mark Griffin","role":"primary","email":"mark.griffin2@va.gov","phone":"704-638-9000 13630","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"caf740c01f5f435aac510a0436d41d00","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"dd7b009e8ae84c3fbff15448458150df","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T03:19:16.858244328Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"46f1295e2113eb4b37679060e885210d541f6d46386fe9469566e03a7d6b8488","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus \nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:  \nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items. \n\nBackground Information: \nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31. \n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\n  Building 42 and Building 43 are served directly from building 31 chilled-water plant.\n  The existing chillers for 42 and 43 are isolated and not in use.\n  Valves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\n  Building 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\n  Building 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\n  Install additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\n  Run new 4\" chilled-water supply and return lines from Building 31 to Building 43.\n  Provide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\n  All new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01   General Requirements \nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete \nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify  T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications \nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32   Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23   Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26   Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27   Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings: \n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.) \n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.) \n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00) \n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.) \n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.) \n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.) \n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.) \n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.) \nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES   regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES   on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES   periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES   travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.) \n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements) \n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.) \nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000. \nNAICS Code 238220 \nSize Standard Table: $19 Million \nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov. \nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","text":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus\nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:\nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items.\n\nBackground Information:\nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31.\n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\nBuilding 42 and Building 43 are served directly from building 31 chilled-water plant.\nThe existing chillers for 42 and 43 are isolated and not in use.\nValves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\nBuilding 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\nBuilding 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\nInstall additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\nRun new 4\" chilled-water supply and return lines from Building 31 to Building 43.\nProvide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\nAll new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01 General Requirements\nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete\nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications\nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32 Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23 Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26 Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27 Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings:\n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.)\n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.)\n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00)\n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.)\n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.)\n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.)\n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.)\n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.)\nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.)\n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements)\n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.)\nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000.\nNAICS Code 238220\nSize Standard Table: $19 Million\nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov.\nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24626B0039","place_of_performance":{"zip":"28144","city":{"name":"Salisbury"},"state":{"code":"NC"},"street":"W.G. Hefner VAMC 1601 Brenner Ave.","country":{"code":"USA"}},"product_service_code":"Z2NZ"}],"due_at":"2026-09-08T14:00:00Z","due_date":"2026-09-08","closes_at":"2026-09-08T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","state":"NC","county":"37159","county_name":"Rowan County","city":"3758860","city_name":"Salisbury","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-24T03:25:58.922164Z","principal_notice_id":"caf740c01f5f435aac510a0436d41d00","description":{"text":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus\nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:\nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items.\n\nBackground Information:\nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31.\n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\nBuilding 42 and Building 43 are served directly from building 31 chilled-water plant.\nThe existing chillers for 42 and 43 are isolated and not in use.\nValves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\nBuilding 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\nBuilding 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\nInstall additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\nRun new 4\" chilled-water supply and return lines from Building 31 to Building 43.\nProvide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\nAll new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01 General Requirements\nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete\nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications\nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32 Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23 Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26 Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27 Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings:\n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.)\n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.)\n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00)\n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.)\n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.)\n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.)\n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.)\n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.)\nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.)\n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements)\n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.)\nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000.\nNAICS Code 238220\nSize Standard Table: $19 Million\nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov.\nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","html":"Subject: Statement of Work: Install Chill Water Lines to Hospice and Audiology\nLocation: Campus \nProject #: 659-24-203\nDate: 26 February 2026\nSTATEMENT OF WORK\nMechanical\nGeneral:  \nThe project involves providing chilled Water from Building 31 primary chiller to serve Buildings 42 and 43. This project should be completed in 365 days and include a 1-year warranty on all items. \n\nBackground Information: \nBuilding 42 and Building 43 are on separate systems, the VA wants them on the same system as Building 31. \n\nSCOPE OF WORK:\nProvide chilled water from the building 31 primary chiller to serve Buildings 42 and 43, bypassing the existing chillers in 42 and 43 during normal operation.\n\nNormal Operation (Primary from Building 31)\n  Building 42 and Building 43 are served directly from building 31 chilled-water plant.\n  The existing chillers for 42 and 43 are isolated and not in use.\n  Valves and actuators shall be connected to the Building Management System (BMS) and automatically controlled for mode selection.\nBypass Mode (Local Chillers in Service)\n  Building 42: The existing chiller serves the 2\" chilled-water line supplying Audiology.\nGlycol shall be replenished through the pot feeder.\n  Building 43: The existing chiller serves the 3\" chilled-water line supplying the building.\nGlycol shall be replenished through the pot feeder.\nNew Work / Modifications\n  Install additional pumps in Building 42 to serve the 2\" chilled-water line to Audiology.\n  Run new 4\" chilled-water supply and return lines from Building 31 to Building 43.\n  Provide emergency backup chilled-water access:\nBuilding 42: Quick-connect ports.\nBuilding 43: Bolted flange connection.\n  All new valves and actuators shall be BMS-integrated for automatic operation and\nremote monitoring.\n\nContractor Trades:\nDivision 01   General Requirements \nRig, hoist, and place pumps, long pipe runs, and large valves especially for elevated or exterior segments.\nDevelop and execute functional performance tests for both modes, including BMS sequences, alarms, failover, and remote monitoring.\nProduce pre-functional checklists, FPT scripts, deficiency logs, and final Cx report.\nImplement Infection Control Risk Assessment (ICRA) measures near Audiology and any patient-care areas: barriers, negative air, dust control, HEPA, clean paths.\nNoise/vibration management during coring and pump installation; off-hours work planning if needed.\nMaintain life safety (egress, fire alarm impairments) and hot work permits.\nMechanical/Electrical permits, right-of-way if exterior work crosses public domain, and VA safety protocols.\nBadging and security clearances for contractors working on campus.\nDivision 2: Existing Conditions\nHazardous materials handling for penetrations in older construction (asbestos/lead). Perform pre-work survey and abate if found.\nPreconstruction survey of pipe routing; locates for existing utilities; as-builts for final turnover.\nDivision 03 -Concrete \nInstall housekeeping pads for pumps or associated equipment in Bldg. 42.\nPerform core drilling, sleeves, and wall/floor penetrations; patch and restore finishes.\nDivision 23: HVAC\nInstall new 4\" chilled-water supply and return from Building 31 to Building 43 (routing, piping, valves, bolted flange connection at Bldg. 43).\nAdd pumps in Building 42 to serve the 2\" CHW line to Audiology (set pumps, suction/discharge fittings, check valves, balancing valves).\nInstall quick-connect ports at Building 42 and bolted flange at Building 43 for emergency backup CHW access.\nProvide/replace valves and actuators; isolate existing chillers in 42 and 43 for normal operation; configure bypass tie-ins.\nHot work (welding/brazing), threaded/flanged connections, equipment anchorage, and system rinsing/flush.\nIntegrate valves and actuators into BMS for automatic mode selection (Normal vs. Bypass).\nProvide points list, sequences of operation, graphics, and alarm/notification setup.\nProgram interlocks between Building 31 plant and local chillers; ensure remote monitoring visibility.\nCoordinate network connectivity to VA systems (per IT/security requirements).\nInsulate new and modified CHW piping, valves, and fittings; provide condensation control and energy code compliance.\nApply pipe identification (color bands, flow arrows) and valve tags.\nHydronic balancing of flows for both Normal Operation (from Bldg. 31) and Bypass Mode (local chillers).\nVerify  T, pump head/curve alignment, and distribution performance to Audiology and Bldg. 43 loads.\nProvide glycol supply and concentration management (both buildings use pot feeders in Bypass Mode).\nTest inhibitor levels, pH, and conductivity; provide documentation and labels for glycol concentration.\nTouch-up coatings on exposed piping and supports; ASME A13.1 compliant pipe marking and valve tags.\nDivision 26: Electrical\nProvide power to new pumps, actuators, and any control panels (breakers, disconnects, conduit, wiring).\nInstall VFDs (if specified/required for pump control), control power transformers as needed.\nBond/ground all new mechanical equipment and supports; label circuits.\nDivision 27: Communications \nRun and terminate BMS cabling (twisted pair, network, I/O), install field panels, power supplies for actuators.\nSupport the controls contractor with panel mounting, device terminations, and point-to-point checkout.\nDivision 31 - Earthwork\nTrenching or directional boring, routing, backfill, and site restoration (hardscape/landscape).\nCoordinate utility locating (public + private locates) and storm/sanitary separation clearances.\nDivision 32   Exterior Improvements\nCoordinate erosion & sediment control, site concrete/flatwork restoration: asphalt cut & patch; pavement markings.\nList of Deliverables:\n1. Project Administration Deliverables\nProject Schedule (Preliminary + Baseline CPM)\nPhasing Plan (if applicable)\nSite Logistics / Staging Plan\nContractor s Quality Control (CQC) Plan\nAccident Prevention Plan (APP)\nActivity Hazard Analyses (AHAs)\nInfection Control Risk Assessment (ICRA)/PCRA coordination documentation\nEmergency Response Plan\nDaily Reports\n\n2. Submittals (01 33 23)\nSubmittal Register (RFI/Submittal log)\nProduct Data for all mechanical/electrical components\nShop Drawings (piping layout, hangers, valves, insulation, electrical routing, controls)\nSamples (insulation, labeling, coatings if any)\nCertifications (welders, equipment, materials)\nO&M Manuals (Mechanical, Electrical, Controls)\nTraining Materials (videos, agendas, attendance logs)\n\n3. Safety Deliverables (01 35 26)\nSafety Orientation Documentation\nHot Work Permits\nFire Watch Logs\nDaily Safety Inspection Reports\nTB Testing Records (as required by VA)\n\n4. Quality Control Deliverables (01 45 00)\nPreparatory Meeting Minutes\nInitial Phase Meeting Minutes\nFollow up QC Inspection Reports\nTesting Reports (pressure test, chemical cleaning, flushing, electrical testing, TAB reports)\nDeficiency/Punch list Logs\n\n5. Environmental Controls Deliverables (01 57 19)\nErosion and Sediment Control Plan\nWastewater/Dewatering Plan\nNoise/Dust Control Measures\n\n6. Waste Management Deliverables (01 74 19)\nConstruction Waste Management Plan\nWaste Diversion Reports (monthly or final)\n\n7. Division 23   Mechanical Deliverables\nHydronic Piping Shop Drawings\nValve & Equipment Schedules\nPump Submittals (curves, motor data, VFD data)\nInsulation Submittals\nWater Treatment Plan & Reports\nTest, Flush, and Chemical Cleaning Reports\nTAB Report (Final)\n\n8. Division 26   Electrical Deliverables\nPanel Schedules\nOne Line Diagrams\nConductor/Conduit Shop Drawings\nGrounding/Bonding Submittals\nMotor/Starter/VFD Submittals\nElectrical Testing Results (megger, torque logs, breaker verification)\n\n9. Division 27   Communications / Controls Deliverables\nDDC Sequences of Operation\nDDC Shop Drawings & Network Architecture\nControls Point to Point Checkout Sheets\nBACnet/IP Integration Documentation\nGraphics Screens (ECC)\nControls Acceptance Test\n\n10. Closeout Deliverables\nAs Built Drawings (redlines + final CAD/PDF)\nFinal O&M Manuals (Mechanical, Electrical, Controls)\nWarranty Certificates\nTraining Records & Materials\nFinal Cleaning & Turnover Sheets\nPunch list Completion Certificate\n\nRequired Meetings: \n1. Pre Construction Meeting (Mandatory)\nHeld after award but before mobilization.\nIncludes:\nReview of schedule\nSubmittal register\nSafety plan\nQC plan\nPhasing and site logistics\n(Referenced broadly across Div 01 requirements.) \n\n2. Pre Activity / Preparatory Meetings (QC Required)\nRequired before each major work activity begins.\nExamples:\nExcavation\nCHW piping installation\nPump installation\nElectrical work\nDDC controls\nInsulation\nTesting & TAB\n(Required by 01 45 00 Quality Control.) \n\n3. Initial and Follow Up QC Meetings\nFor each definable feature of work:\nInitial: Review workmanship standards and inspection criteria\nFollow up: Ensures corrective actions are closed\n(Required by 01 45 00) \n\n4. Weekly Progress Meetings\nTypically held with:\nCOR\nProject Manager\nSafety Officer\nCQC Manager\nTrades/Prime Contractor\nAgenda includes schedule, submittals, RFIs, safety, and progress.\n(Implied by Div 01 administrative requirements.) \n\n5. Safety Meetings\nRequired by 01 35 26 Safety Requirements.\nIncludes:\nDaily safety briefs (toolbox talks)\nIncident reporting review\nActivity Hazard Analysis reviews\nFire watch and hot work coordination\n\n6. Environmental / Waste Management Coordination\nIf erosion control or waste diversion tasks trigger compliance updates:\nE&S compliance checks\nWaste management plan reviews\n(From 01 57 19 and 01 74 19.) \n\n7. Controls & Commissioning Meetings\nRequired for DDC and system turnover:\nControls integration coordination\nECC graphics review\nPre functional testing meeting\nFunctional testing/commissioning meeting\n(Driven by Div 23 & Div 26 controls requirements.) \n\n8. Substantial Completion / Punch list Meeting\nWalkthrough with COR, A/E, and contractor\nTracking and resolution of deficiencies\n(Mandated in Div 01 closeout procedures.) \n\n9. Final Completion Meeting\nFinal inspections\nAcceptance of deliverables (as builts, O&M manuals, training records)\nContract closeout\n(From Div 01 closeout requirements.) \nTravel:\n1. Contractor Project Manager / Superintendent\nThese roles must be physically present for:\nPre construction meeting\nPreparatory meetings\nWeekly progress meetings\nInspections, site walkthroughs\nSubstantial & final completion\nYES   regular trips to the Salisbury VAMC campus are required.\n\n2. Safety Officer (SSHO)\nSpec 01 35 26 requires daily safety oversight.\nDepending on contract structure:\nFull time on site (common for VA projects)\nor Regular, recurring on site presence\nYES   on site presence required.\n\n3. Quality Control Manager (CQC)\nSpec 01 45 00 requires the CQC Manager to attend:\nPreparatory meetings\nInitial + follow up inspections\nTesting (flushing, pressure test, balancing)\nYES   periodic onsite travel required.\n\n4. Specialty Technicians / Commissioning / Controls\nTypically:\nPump technician (factory startup)\nTAB technician\nDDC controls programmer\nThese may be traveling vendor reps depending on who is hired.\nYES   travel required if vendors are coming from off site.\n\n5. Office Only Personnel\nDocument control, estimators, accounting, schedulers:\nNo required travel.\nSpecial Instructions:\n1. Compliance With VA Safety Requirements\nContractor must comply fully with 01 35 26 Safety Requirements, including:\nAccident Prevention Plan (APP) approval before work begins\nDaily Activity Hazard Analyses (AHAs)\nDaily safety inspections\nHot work permit requirements\nFire watch assignments when required\nTB screening requirements for personnel\n\n2. Quality Control (CQC) Procedures\nPer 01 45 00, the contractor shall:\nProvide a qualified CQC Manager\nHold preparatory, initial, and follow up QC meetings for each definable feature of work\nMaintain QC logs daily\nSubmit all testing documentation (pressure tests, chemical cleaning, flushing, TAB, electrical testing)\n\n3. Submittal and Documentation Requirements\nAccording to 01 33 23, special attention must be given to:\nCreation and maintenance of a Submittal Register\nTimely shop drawing and product data submission\nEquipment schedules (pumps, valves, motors, controls)\nFinal O&M manuals and training documentation\nAs built drawings (redlines required daily)\n\n4. Environmental and Site Protection Requirements\nFrom 01 57 19 Environmental Controls:\nMaintain erosion and sediment controls at all times\nControl dust, debris, and noise during excavation and saw cutting\nProtect existing utilities, structures, and vegetation\n\n5. Construction Waste Management\nPer 01 74 19, contractor must:\nProvide a Waste Management Plan\nDocument diversion of recyclables\nProperly dispose of demo waste and piping insulation\n\n6. Site Access and Coordination\nAll work must be coordinated with VA facilities to maintain operations.\nWork in active clinical areas requires advance notice and may require off hours scheduling.\n(Supported by VA General Requirements.) \n\n7. Protection of Existing Utilities\nPer site survey requirements in 02 21 13, the contractor must:\nVerify underground and above ground utility locations\nUse GPR/locates before excavation\nPrevent disruption of medical services\n\n8. Required Testing & Commissioning Activities\nPressure test all chilled water piping\nChemical cleaning, flushing, water treatment verification\nTAB (Test, Adjust, Balance) for hydronic system (23 05 93)\nControls point to point checkout (Div 23/27)\n\n9. Delivery, Storage, and Protection of Equipment\nProtect mechanical equipment and materials from weather\nStore DDC controls and electrical components in conditioned environments\n(Division 01 handling requirements) \n\n10. Coordination With Other Trades\nElectrical and controls work must be coordinated with mechanical piping installation\nPump alignment and VFD integration require sequencing with mechanical and electrical crews\n(Supported across Divisions 23 & 26.) \nEnd Statement of Work\nEstimated construction magnitude is between $2,000,000 and $5,000,000. \nNAICS Code 238220 \nSize Standard Table: $19 Million \nThis solicitation is anticipated to be a Total Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. In accordance with Public Law 109-461 and VAAR 819.7003 (b), offerors must be registered and certified in the SBA Certification database (https://search.certifications.sba.gov/) as a SDVOSB. Only offers from certified SDVOSBs in the SBA database at the time of offer shall be deemed eligible for award. Network Contracting Office 6 (NCO 6) intends to issue a Invitation for Bids (IFB) and award a single, firm fixed-price contract. Solicitation material will be available on/about August 5, 2026. Any specifications, drawings and amendments will be posted on the System for Award Management (SAM) Contract Opportunities website (https://sam.gov/opportunities). The Contract Opportunities website is the only official location to obtain solicitation information and documents. Offers will be due approximately 30 days after issuance of the solicitation. Only one (1) site visit will be scheduled. Location and point(s) of contact for the site visit will be identified in the solicitation. This notice is for informational purposes only and is not a request for quotation. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No offerors list is maintained. All interested vendors should register on SAM.gov. Interested offerors are advised they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers and should revisit the website periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the SAM database in order to obtain access in Contract Opportunities. SAM and SBA Certification Database registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal. Any questions regarding this announcement and all future announcements regarding this project must be emailed to the Contracting Officer, Mark Griffin, at mark.griffin2@va.gov. \nNO TELEPHONE REQUESTS FOR SOLICIATION MATERIAL WILL BE ACCEPTED.","origin":"detail"},"contacts":[{"name":"Mark Griffin","role":"primary","email":"mark.griffin2@va.gov","phone":"704-638-9000 13630","title":"Contract Specialist"}],"place_of_performance":{"zip":"28144","city":{"name":"Salisbury"},"state":{"code":"NC"},"street":"W.G. Hefner VAMC 1601 Brenner Ave.","country":{"code":"USA"}},"office_address":{"zip":"23667","city":"HAMPTON","state":"VA","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"f475daac3e2d4a22b345f3e5e4198698","name":"36C24626B0039.docx","kind":"file","mime_type":".docx","size_bytes":27883,"posted_at":"2026-07-21T17:53:02.367Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f475daac3e2d4a22b345f3e5e4198698/download","mirrored":false}],"awards":[],"related":[{"key":"36C24627Q0149","latest_notice_id":"0f55c0d6fb1b4b4c8be2a3cdcb19cfc5","title":"5670--Dumpster Area Roll Up Door Replacement","solicitation_number":"36C24627Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"332321","psc":"5670","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24627Q0153","latest_notice_id":"4d24e9c5db104196af7772b612e1b14c","title":"8470-- Police Ballistic Vests","solicitation_number":"36C24627Q0153","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"315990","psc":"8470","set_aside":null,"state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24626Q10991","latest_notice_id":"8689b6e16d9540bb8e955fa0fe26acb8","title":"LOADING DOCK CONCRETE REPAIRS","solicitation_number":"36C24626Q1099_1","notice_type":"o","first_type":"o","first_posted":"2026-10-23","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238110","psc":"Z1DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24627R0011","latest_notice_id":"3d14d2e074b241d98dbfed766bfdb01a","title":"Z2DA--652-23-109 Renovate SPS Phase 3","solicitation_number":"36C24627R0011","notice_type":"p","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T21:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"VA","county":"51760","county_name":"City of Richmond","city":"5167000","city_name":"Richmond","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24626B0041","latest_notice_id":"386b9ba47ba540ba974b1f3ac521e4de","title":"Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009)","solicitation_number":"36C24626B0041","notice_type":"p","first_type":"p","first_posted":"2026-09-18","last_posted":"2026-10-23","notices":2,"due_at":"2026-12-03T02:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-03T02:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"A HEALTH CARE CENTER, 508 FULTON ST, DURHAM, NC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open":[{"key":"1240BE27Q0025","latest_notice_id":"c21abfebfc5d4ee1a6b74dffe96d5bdf","title":"Research Triangle Park Forestry Sciences Laboratory HVAC Repair","solicitation_number":"1240BE27Q0025","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-01T22:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-124568","office_name":"SOUTHERN RESEARCH STATION","naics":"238220","psc":"J041","set_aside":"SBA","state":"NC","county":"37063","county_name":"Durham County","city":"3719000","city_name":"Durham","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25627Q0087","latest_notice_id":"cd7d881bb8cc47e4b482d18db8376dea","title":"Z2NZ--Turn Key Chiller Equipment (Purchase and Install)","solicitation_number":"36C25627Q0087","notice_type":"o","first_type":"o","first_posted":"2026-10-26","last_posted":"2026-11-16","notices":5,"due_at":"2026-12-02T16:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238220","psc":"Z2NZ","set_aside":"SDVOSBC","state":"NC","county":"37119","county_name":"Mecklenburg County","city":"3752220","city_name":"Pineville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":57,"indexable":false}