Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,695 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Sources sought, total small business set-aside

Cabinet, Bio Safety, Class II B2, F/S, 4ft

36C24625Q0681

Department of Veterans Affairs, 246-Network Contracting Office 6. Surgical and Medical Instrument Manufacturing.

Response deadline

May 9, 2025 at 8:00 AM EDT

Closed 566 days ago. Posted May 2, 2025. Scheduled to archive July 8, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

15 like it are open now in surgical and medical instrument manufacturing

All 15 open in surgical and medical instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
Total small business set-aside. Only small businesses may compete. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. Open Small business opportunities
What comes next
No solicitation was published under this number after the sources sought of May 2, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Sources Sought Notice Sources Sought Notice Page 5 of 5 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 5 This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. The Government will not pay for any information solicited.  The Department of Veterans Affairs Medical Center, Network Contracting Office (NCO) 6, on behalf of the Durham VA Medical Center, is conducting market research for capable SDVOSB and VOSB s to provide a Biosafety cabinet, Class II B2 4ft. Equipment must have the physical characteristics to enable the government to perform the capabilities: L2335 Cabinet, Bio Safety, Class II B2, F/S, 4ft by Labconco Class II biosafety cabinets (BSCs) are USP <797> and <800> compliant for compounding hazardous sterile preparations. Models will provide ISO 5 or better air in the compounding area, with highest quality features to promote safety for compounders and patients alike. Human-centric design, operational intelligence, and easily cleanable surfaces are ideal for safe and comfortable compounding. Class II, Type B2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containments. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. The proposed model will be NSF compliant. These biological safety cabinets are designed to be hard ducted to a facility exhaust system. During operation, room air is drawn into the top of the cabinet and through a supply HEPA filter. This filtered air flows downward through the work area. Room air is also drawn into the inlet grille located at the work access opening. All of the contaminated air passes through the exhaust HEPA filter. A dedicated exhaust system and remote blower discharge 100% of the filtered exhaust air from the room. A smooth interior improves cleanability for USP 800 compliance. Configure with an IV bar, base stand, and Ergotron arm to maximize compounding accuracy through aseptic technique. Air Cleanliness (ISO 14644): ISO-Class-5 Airflow Monitor: AirflowSensorPressureGrid Bag In Bag Out: Optional Cabinet Construction: All welded stainless steel 16/18 GA, Type 304 pressure tight design Casters: N/A Control System: TouchLink Cord Pass Through: Standard Right Data Output Features: RS-232, USB Decontamination Seal-able Window: N/A Diffuser Metal, non-flammable Downflow fpm (m/s): 60 fpm (0.30 m/s) Drain Valve Location: Front right Front & Control Panel Material: Painted Steel Fumigation: per NIH/NSF Procedures: True HEPA Filter Seal Type: HEPEX Zero Leak Neoprene Seal, Spring-loaded Inflow fpm (m/s): 105 fpm (0.53 m/s) ***IV Bar with 6 Hooks: INCLUDE IN ORDER*** Light Intensity fc (Lux): 90-120 (968-1291) Motorized Base Stand: Optional as Separate Accessory Motorized Window: N/A Other Built-in Exhaust Option(s): N/A Other Built-in Supply Filter Option(s): N/A Outlet(s): One Left Front Faring, Optional One Right Front Faring Performance Standard: NSF-ANSI-49 Plenum Type: HEPEX Pre-filter: N/A Protection: Product, Personnel, Environmental Reach into workzone Inches (mm): 6 (152) Remote Alarm Terminals: Standard Safety Certification: UL, UL-C ***Style: Bench top, INCLUDE base stand*** Ultraviolet (UV) Light: Optional, Backwall (user preference) Viewing Window Inches (mm): 18.5 (470) open to fully closed Work Access Opening(s): 8-inches (203 mm) Work Surface: One-Piece Dished Stainless Steel with Prop-Up Rod Electrical Configuration: 115V/60Hz, Rated Amps 12 Power Cord Length Foot (Meter): 10 (3), 14 GA - 3 Wire, 15A Blower/Lights Amps: 2.1 Junction Box: Optional Outlet Amps: 3 Exhaust: 12 duct hard connection to facility. Direct Connection Exhaust Requirement Concurrent Balance Value, CFM(CMH): 815 (1385) Plant Duct Static Pressure Inches (mm) 1.7 w.g. (43mm w.g.) The North American Industry Classification System (NAICS) Code for this acquisition is 339112 Surgical and Medical Instrument Manufacturing Size Standard 1,000 Employees, and the Product Service Code (PSC) Classification is 6640. Interested parties should submit with their response the following information: 1. Company name and UEI# 2. POC information 3. Business size and socio-economic classification 4. Capabilities Statement Interested Vendors must be registered in the System for Award Management (SAM) www.sam.gov   Please email this information to Patsy Simpson at Patsy.Simpson@va.gov no later than 8:00 AM, May 09, 2025.  Phone inquiries will not be accepted.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. May 2, 2025

    Sources sought

    Due May 9, 2025 at 8:00 AM EDT. SAM.gov, notice e278552de6ce4d559e7d3eab5e85ab7b

    1 revision on SAM
    • May 2, 2025: publish, sources sought

Points of contact