{"canonical":"https://sealedbidder.com/opportunities/36c24527q0083","key":"36C24527Q0083","url":"https://sealedbidder.com/opportunities/36c24527q0083","title":"J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC","solicitation_number":"36C24527Q0083","notice_type":"r","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-12-15T15:00:00Z","first_posted":"2026-11-23","last_posted":"2026-11-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561621","psc":"J063","set_aside":null,"place_state":"DC","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"11001","place_county_name":"District of Columbia","place_city":"1150000","place_city_name":"Washington","winner":null,"award_amount":null,"publications":[{"notice_id":"45d08f759966476d9d29fd7f47d9cd6c","title":"J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC","solicitation_number":"36C24527Q0083","notice_type":"r","base_type":"r","posted":"2026-11-23","posted_at":"2026-11-23T17:49:27.498Z","due_at":"2026-12-15T15:00:00Z","due_date":"2026-12-15","cancelled":false,"archived":false,"archive_date":"2027-02-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/45d08f759966476d9d29fd7f47d9cd6c/view","enriched":true,"history":[{"index":1,"title":"J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-23T17:49:27.498Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"45d08f759966476d9d29fd7f47d9cd6c","solicitation_number":"36C24527Q0083"}]}],"latest_notice_id":"45d08f759966476d9d29fd7f47d9cd6c","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-11-23","posted_at":"2026-11-23T17:49:27.498Z","created_at":"2026-11-23T17:49:24.962Z","modified_at":"2026-11-23T17:49:27.498Z","response_deadline":{"raw":"2026-12-15T10:00:00-05:00","utc":"2026-12-15T15:00:00Z","date":"2026-12-15","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/45d08f759966476d9d29fd7f47d9cd6c/view"},"naics":{"codes":["561621"],"primary":"561621"},"title":"J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-02-13","archive_type":"auto_custom"},"history":[{"index":1,"title":"J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-23T17:49:27.498Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"45d08f759966476d9d29fd7f47d9cd6c","solicitation_number":"36C24527Q0083"}],"contacts":[{"name":"Bill Pratt","role":"primary","email":"Billie.Pratt@va.gov","phone":"410-642-2411","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"45d08f759966476d9d29fd7f47d9cd6c","lineage_id":"45d08f759966476d9d29fd7f47d9cd6c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T06:43:36.852518490Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"de1d8a93e132aef6c7e287564f07f6c7-28\"","fetched_at":"2026-11-24T04:39:59.921451404Z","row_sha256":"4e62ccef9ff88bdd8fd696de042a95d4a05270549361c9ff974e896848946d14","last_modified":"2026-11-24T04:30:19Z"},"updated_at":"2026-11-24T06:43:36.852518490Z","first_seen_at":"2026-11-24T04:39:59.921451404Z"},"description":{"html":"SUMMARY\nThe Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services.\nThe Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required.\nNCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services.\nAnticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063\nPlease submit your capabilities statement and provide responses to all questions listed below.\nSOURCES SOUGHT NOTICE: 36C24527Q0083\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services\nfor the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the\nDC VAMC (if applicable)\n8. Confirmation that your organization has the capability and expertise to meet the performance\nrequirements while complying with applicable limitations in subcontracting by responding to the\nquestions below with your response:\n\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nIf you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nRespond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET. \nSend all responses to Billie.Pratt@va.gov \n\nSubject line on email: \n36C24527Q0083   Sources Sought Notice | Company Name\nSTATEMENT OF WORK\nParking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement \nDepartment of Veterans Affairs  |  Washington DC VA Medical Center\n50 Irving Street NW, Washington, DC 20422\nDraft dated October 27, 2026\n1. BACKGROUND\nThe Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access.\nVA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods.\n2. SCOPE OF WORK\nThe Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are \"or equal.\"\n3. LOCATIONS AND EXISTING CONDITIONS\nItem\nLocation / Type\nQuantity\nNotes\n1\nBarrier-arm gates (standard duty, 12 14 ft arm)\n17\nParking lots and service drives; includes separated Fisher House locations.\n2\nBarrier-arm gate (long arm, approx. 20 ft)\n1\nHeavy-duty operator; status reporting appropriate to hardware.\n3\nSlide gate   Utility Building 8\n1\nReuse existing gate panel; convert from top track to bottom steel cantilever track.\n4\nLots 3B and 4B\nGates as installed (verify)\nRelocatable (forklift-movable) foundations and flexible wiring for planned two-way operation.\n\nTotal gate locations\n19\nContractor shall verify all locations and conditions during the mandatory site visit.\n\nExisting 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope.\n4. TECHNICAL REQUIREMENTS   GATE SYSTEM\n4.1 Removal and Disposal\nRemove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads.\nRemoval and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan.\n4.2 Barrier Gate Operators\nCommercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable.\nIntegral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service.\nLED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system.\nAbove-ground radar (\"virtual loop\") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations.\nOne (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property.\n4.3 Slide Gate   Utility Building 8\nConvert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required.\nFurnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable.\n4.4 Relocatable Foundations   Lots 3B and 4B\nProvide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey.\n4.5 Remote Monitoring and Control\nProvide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release.\nThe dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available.\nAll life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices.\nCommunications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO.\n4.6 Event Cameras\nNineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events.\nCloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only.\n4.7 Cloud Platform, Information Security and Privacy\nThe hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled.\nAll data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract.\nUser access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication.\n4.8 Commissioning, Testing and Training\nSubmit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police.\nProvide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover.\n4.9 Warranty\nMinimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA.\n5. MANDATORY SUBCONTRACT   JOHNSON CONTROLS, INC. (PIV BADGE READERS)\nThe VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply:\nSubcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty.\nReaders. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration.\nControllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to the PACS head-end as approved in writing by VA OIT/ISSO and VA Police Service.\nGate integration. Valid credential reads shall release the associated gate through a dry-contact interface coordinated between JCI and the prime; gate position and fault signals shall be made available to the PACS where supported.\nVA Police control. Upon completion, VA Police Service shall be able, from the C CURE workstation, to grant/revoke parking access by credential, set access levels and schedules by lot, lock down or hold open any gate, and view reader/door event history.\nPersonnel. JCI technicians shall be factory-certified on C CURE 9000/iSTAR and shall meet the background investigation and privileged-access requirements for work on a VA network-connected security system.\nService. For each option period exercised, the JCI subcontract shall include maintenance, firmware updates and repair of the readers and controllers installed under this contract.\n6. SERVICE AGREEMENT (BASE YEAR + FOUR OPTION YEARS)\nThe service agreement begins on the date of final acceptance of the installation and continues through the base period and each option period exercised by the Government. It covers all 19 gates and all equipment installed under this contract.\n6.1 Preventive Maintenance (PM)\nQuarterly PM at each gate per manufacturer schedules, including UL 325 entrapment-device testing, battery load testing, arm/flange/sensor inspection, radar detector alignment, camera and storage health, and firmware review. Provide a written PM checklist per gate to the COR within 5 business days of each PM cycle.\n6.2 Remote Monitoring\nAutomated 24/7 monitoring of gate fault, communication-loss and arm-displacement alerts. Contractor shall review each alert and begin remote troubleshooting within 2 hours (business hours) or by 9:00 a.m. the next business day (after hours), and notify the COR/VA Police of any gate not restored remotely.\n6.3 Corrective Maintenance and Response Times\nPriority\nCondition\nOn-site response\nRestore / make safe\nEmergency\nGate stuck closed blocking emergency vehicle route, or stuck open where VA Police declare a security need; safety hazard\n4 hours, 24/7/365\nMake safe / manual mode within 4 hours; restore within 24 hours\nUrgent\nGate inoperable but alternate access available\nNext business day\nWithin 2 business days (parts permitting)\nRoutine\nDegraded function (camera, LED, single sensor)\nWithin 3 business days\nWithin 5 business days\n\nFailures from normal wear, defects and equipment age are covered under the firm-fixed price (labor and parts) during warranty and under the service agreement thereafter.\nDamage from vehicle strikes, vandalism or acts of God is repaired under the Corrective Labor and Repair Parts CLINs at the fixed hourly rate and contract parts pricing, only after COR approval of a written estimate (emergency make-safe excepted).\n6.4 Subscriptions and Data Services\nAll cloud platform, monitoring, user, device and cellular data subscriptions required for system operation are included at a fixed annual price for each period. No surcharges, data overages or price increases are permitted except as priced in the option periods.\n6.5 Performance Standard\nMonthly system availability of at least 98% per gate (excluding approved PM windows and damage caused by others). The Contractor shall report monthly availability, alerts, response times and repairs to the COR.\n7. PERIOD OF PERFORMANCE AND SCHEDULE\nPeriod\nEstimated dates (adjust to award)\nContent\nBase Year\n02/01/2027   01/31/2028\nInstallation complete within 120 calendar days after Notice to Proceed; JCI reader integration; warranty; service agreement and subscriptions from acceptance\nOption Year 1\n02/01/2028   01/31/2029\nService agreement, subscriptions, JCI reader maintenance\nOption Year 2\n02/01/2029   01/31/2030\nSame as Option Year 1\nOption Year 3\n02/01/2030   01/31/2031\nSame as Option Year 1\nOption Year 4\n02/01/2031   01/31/2032\nSame as Option Year 1\n\nMilestone\nDue\nKick-off meeting (prime, JCI, COR, VA Police, OIT/ISSO, Safety)\nWithin 10 days of award\nSite survey report, submittals (product data, shop drawings, NDAA certifications, FedRAMP/ATO evidence), installation schedule & traffic plan\nWithin 30 days of award\nInstallation start (after submittal approval)\nPer approved schedule\nAcceptance testing and training\nWithin 120 days of NTP\nAs-builts, O&M manuals, credential turnover\nWithin 15 days after acceptance\n8. HOURS OF WORK, ACCESS AND COORDINATION\nNormal work hours: Monday Friday, 7:00 a.m. 3:30 p.m., excluding Federal holidays. Work outside these hours requires 48-hour advance COR approval. Emergency service is 24/7.\nContractor personnel shall check in with VA Police Service, wear VA-issued or company photo identification, and follow traffic-control plans meeting the MUTCD. Utility locates are required before any excavation or anchoring.\nThe Contractor shall maintain at least one functioning entry and exit per parking area during working hours or provide manual operation coordinated with VA Police.\n9. CONTRACTOR PERSONNEL SECURITY\nContractor and subcontractor personnel shall complete background investigations at the risk level designated by the VA Position Designation Tool (anticipated Tier 1 / Low Risk for gate technicians; higher for JCI personnel with privileged PACS access) per VA Directive and Handbook 0710.\nPersonnel requiring access to VA information or systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior training before access and annually thereafter.\n10. SAFETY, CODES AND STANDARDS\nUL 325 (Door, Drapery, Gate, Louver and Window Operators and Systems) and ASTM F2200 (Automated Vehicular Gate Construction)\nNFPA 70, National Electrical Code; OSHA 29 CFR 1910 and 1926; lock-out/tag-out\nFIPS 201-3 and GSA FIPS 201 Approved Products List; OMB M-19-17 (FICAM)\nVA Handbook 6500.6 (Contract Security); VA Directive 0730 (Security and Law Enforcement); VA Physical Security and Resiliency Design Manual\nFAR 52.204-25 (Section 889) and FAR 52.204-23/-27 prohibitions; Buy American / Trade Agreements as determined by the CO\nManufacturer installation instructions\n11. GOVERNMENT-FURNISHED ITEMS AND RESPONSIBILITIES\nExisting 120 VAC power at each location; access to sites with escort as required; VA Police PACS administrator support; VA OIT/ISSO review of PACS communications and cloud security documentation; designation of COR and alternate.\n12. DELIVERABLES\n#\nDeliverable\nDue\nTo\n1\nquotation / letter of commitment (with offer)\nWith quote\nCO\n2\nSite survey report; installation schedule; traffic plan\n30 days after award\nCOR\n3\nSubmittals incl. NDAA 889 and FIPS 201 APL certifications; FedRAMP/ATO evidence for cloud platform\n30 days after award\nCOR / ISSO\n4\nAcceptance Test Plan; completed test reports\n10 days before test / at test\nCOR\n5\nAs-built drawings, O&M manuals, programming & credential turnover\n15 days after acceptance\nCOR\n6\nQuarterly PM checklists per gate\n5 business days after each PM\nCOR\n7\nMonthly performance report (availability, alerts, response, repairs)\n10th day of following month\nCOR\n8\nWritten estimates for damage repairs\nBefore work (except make-safe)\nCOR\n13. PERFORMANCE REQUIREMENTS SUMMARY\nPerformance objective\nStandard\nAcceptable quality level\nSurveillance\nInstallation complete\nAll 19 gates and readers accepted\nWithin 120 days of NTP\nCOR inspection / test witness\nPreventive maintenance\nQuarterly PM at every gate\n100% completed and documented\nPM checklist review\nEmergency response\nOn site within 4 hours\n95% of calls\nCall log / VA Police records\nSystem availability\n  98% per gate per month\n  98%\nMonthly report; platform data\nRemote alert review\nWithin 2 business hours\n95% of alerts\nPlatform audit log","text":"SUMMARY\nThe Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services.\nThe Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required.\nNCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services.\nAnticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063\nPlease submit your capabilities statement and provide responses to all questions listed below.\nSOURCES SOUGHT NOTICE: 36C24527Q0083\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services\nfor the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the\nDC VAMC (if applicable)\n8. Confirmation that your organization has the capability and expertise to meet the performance\nrequirements while complying with applicable limitations in subcontracting by responding to the\nquestions below with your response:\n\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nIf you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nRespond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET.\nSend all responses to Billie.Pratt@va.gov\n\nSubject line on email:\n36C24527Q0083 Sources Sought Notice | Company Name\nSTATEMENT OF WORK\nParking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement\nDepartment of Veterans Affairs | Washington DC VA Medical Center\n50 Irving Street NW, Washington, DC 20422\nDraft dated October 27, 2026\n1. BACKGROUND\nThe Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access.\nVA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods.\n2. SCOPE OF WORK\nThe Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are \"or equal.\"\n3. LOCATIONS AND EXISTING CONDITIONS\nItem\nLocation / Type\nQuantity\nNotes\n1\nBarrier-arm gates (standard duty, 12 14 ft arm)\n17\nParking lots and service drives; includes separated Fisher House locations.\n2\nBarrier-arm gate (long arm, approx. 20 ft)\n1\nHeavy-duty operator; status reporting appropriate to hardware.\n3\nSlide gate Utility Building 8\n1\nReuse existing gate panel; convert from top track to bottom steel cantilever track.\n4\nLots 3B and 4B\nGates as installed (verify)\nRelocatable (forklift-movable) foundations and flexible wiring for planned two-way operation.\n\nTotal gate locations\n19\nContractor shall verify all locations and conditions during the mandatory site visit.\n\nExisting 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope.\n4. TECHNICAL REQUIREMENTS GATE SYSTEM\n4.1 Removal and Disposal\nRemove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads.\nRemoval and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan.\n4.2 Barrier Gate Operators\nCommercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable.\nIntegral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service.\nLED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system.\nAbove-ground radar (\"virtual loop\") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations.\nOne (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property.\n4.3 Slide Gate Utility Building 8\nConvert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required.\nFurnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable.\n4.4 Relocatable Foundations Lots 3B and 4B\nProvide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey.\n4.5 Remote Monitoring and Control\nProvide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release.\nThe dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available.\nAll life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices.\nCommunications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO.\n4.6 Event Cameras\nNineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events.\nCloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only.\n4.7 Cloud Platform, Information Security and Privacy\nThe hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled.\nAll data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract.\nUser access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication.\n4.8 Commissioning, Testing and Training\nSubmit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police.\nProvide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover.\n4.9 Warranty\nMinimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA.\n5. MANDATORY SUBCONTRACT JOHNSON CONTROLS, INC. (PIV BADGE READERS)\nThe VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply:\nSubcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty.\nReaders. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration.\nControllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to the PACS head-end as approved in writing by VA OIT/ISSO and VA Police Service.\nGate integration. Valid credential reads shall release the associated gate through a dry-contact interface coordinated between JCI and the prime; gate position and fault signals shall be made available to the PACS where supported.\nVA Police control. Upon completion, VA Police Service shall be able, from the C CURE workstation, to grant/revoke parking access by credential, set access levels and schedules by lot, lock down or hold open any gate, and view reader/door event history.\nPersonnel. JCI technicians shall be factory-certified on C CURE 9000/iSTAR and shall meet the background investigation and privileged-access requirements for work on a VA network-connected security system.\nService. For each option period exercised, the JCI subcontract shall include maintenance, firmware updates and repair of the readers and controllers installed under this contract.\n6. SERVICE AGREEMENT (BASE YEAR + FOUR OPTION YEARS)\nThe service agreement begins on the date of final acceptance of the installation and continues through the base period and each option period exercised by the Government. It covers all 19 gates and all equipment installed under this contract.\n6.1 Preventive Maintenance (PM)\nQuarterly PM at each gate per manufacturer schedules, including UL 325 entrapment-device testing, battery load testing, arm/flange/sensor inspection, radar detector alignment, camera and storage health, and firmware review. Provide a written PM checklist per gate to the COR within 5 business days of each PM cycle.\n6.2 Remote Monitoring\nAutomated 24/7 monitoring of gate fault, communication-loss and arm-displacement alerts. Contractor shall review each alert and begin remote troubleshooting within 2 hours (business hours) or by 9:00 a.m. the next business day (after hours), and notify the COR/VA Police of any gate not restored remotely.\n6.3 Corrective Maintenance and Response Times\nPriority\nCondition\nOn-site response\nRestore / make safe\nEmergency\nGate stuck closed blocking emergency vehicle route, or stuck open where VA Police declare a security need; safety hazard\n4 hours, 24/7/365\nMake safe / manual mode within 4 hours; restore within 24 hours\nUrgent\nGate inoperable but alternate access available\nNext business day\nWithin 2 business days (parts permitting)\nRoutine\nDegraded function (camera, LED, single sensor)\nWithin 3 business days\nWithin 5 business days\n\nFailures from normal wear, defects and equipment age are covered under the firm-fixed price (labor and parts) during warranty and under the service agreement thereafter.\nDamage from vehicle strikes, vandalism or acts of God is repaired under the Corrective Labor and Repair Parts CLINs at the fixed hourly rate and contract parts pricing, only after COR approval of a written estimate (emergency make-safe excepted).\n6.4 Subscriptions and Data Services\nAll cloud platform, monitoring, user, device and cellular data subscriptions required for system operation are included at a fixed annual price for each period. No surcharges, data overages or price increases are permitted except as priced in the option periods.\n6.5 Performance Standard\nMonthly system availability of at least 98% per gate (excluding approved PM windows and damage caused by others). The Contractor shall report monthly availability, alerts, response times and repairs to the COR.\n7. PERIOD OF PERFORMANCE AND SCHEDULE\nPeriod\nEstimated dates (adjust to award)\nContent\nBase Year\n02/01/2027 01/31/2028\nInstallation complete within 120 calendar days after Notice to Proceed; JCI reader integration; warranty; service agreement and subscriptions from acceptance\nOption Year 1\n02/01/2028 01/31/2029\nService agreement, subscriptions, JCI reader maintenance\nOption Year 2\n02/01/2029 01/31/2030\nSame as Option Year 1\nOption Year 3\n02/01/2030 01/31/2031\nSame as Option Year 1\nOption Year 4\n02/01/2031 01/31/2032\nSame as Option Year 1\n\nMilestone\nDue\nKick-off meeting (prime, JCI, COR, VA Police, OIT/ISSO, Safety)\nWithin 10 days of award\nSite survey report, submittals (product data, shop drawings, NDAA certifications, FedRAMP/ATO evidence), installation schedule & traffic plan\nWithin 30 days of award\nInstallation start (after submittal approval)\nPer approved schedule\nAcceptance testing and training\nWithin 120 days of NTP\nAs-builts, O&M manuals, credential turnover\nWithin 15 days after acceptance\n8. HOURS OF WORK, ACCESS AND COORDINATION\nNormal work hours: Monday Friday, 7:00 a.m. 3:30 p.m., excluding Federal holidays. Work outside these hours requires 48-hour advance COR approval. Emergency service is 24/7.\nContractor personnel shall check in with VA Police Service, wear VA-issued or company photo identification, and follow traffic-control plans meeting the MUTCD. Utility locates are required before any excavation or anchoring.\nThe Contractor shall maintain at least one functioning entry and exit per parking area during working hours or provide manual operation coordinated with VA Police.\n9. CONTRACTOR PERSONNEL SECURITY\nContractor and subcontractor personnel shall complete background investigations at the risk level designated by the VA Position Designation Tool (anticipated Tier 1 / Low Risk for gate technicians; higher for JCI personnel with privileged PACS access) per VA Directive and Handbook 0710.\nPersonnel requiring access to VA information or systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior training before access and annually thereafter.\n10. SAFETY, CODES AND STANDARDS\nUL 325 (Door, Drapery, Gate, Louver and Window Operators and Systems) and ASTM F2200 (Automated Vehicular Gate Construction)\nNFPA 70, National Electrical Code; OSHA 29 CFR 1910 and 1926; lock-out/tag-out\nFIPS 201-3 and GSA FIPS 201 Approved Products List; OMB M-19-17 (FICAM)\nVA Handbook 6500.6 (Contract Security); VA Directive 0730 (Security and Law Enforcement); VA Physical Security and Resiliency Design Manual\nFAR 52.204-25 (Section 889) and FAR 52.204-23/-27 prohibitions; Buy American / Trade Agreements as determined by the CO\nManufacturer installation instructions\n11. GOVERNMENT-FURNISHED ITEMS AND RESPONSIBILITIES\nExisting 120 VAC power at each location; access to sites with escort as required; VA Police PACS administrator support; VA OIT/ISSO review of PACS communications and cloud security documentation; designation of COR and alternate.\n12. DELIVERABLES\n#\nDeliverable\nDue\nTo\n1\nquotation / letter of commitment (with offer)\nWith quote\nCO\n2\nSite survey report; installation schedule; traffic plan\n30 days after award\nCOR\n3\nSubmittals incl. NDAA 889 and FIPS 201 APL certifications; FedRAMP/ATO evidence for cloud platform\n30 days after award\nCOR / ISSO\n4\nAcceptance Test Plan; completed test reports\n10 days before test / at test\nCOR\n5\nAs-built drawings, O&M manuals, programming & credential turnover\n15 days after acceptance\nCOR\n6\nQuarterly PM checklists per gate\n5 business days after each PM\nCOR\n7\nMonthly performance report (availability, alerts, response, repairs)\n10th day of following month\nCOR\n8\nWritten estimates for damage repairs\nBefore work (except make-safe)\nCOR\n13. PERFORMANCE REQUIREMENTS SUMMARY\nPerformance objective\nStandard\nAcceptable quality level\nSurveillance\nInstallation complete\nAll 19 gates and readers accepted\nWithin 120 days of NTP\nCOR inspection / test witness\nPreventive maintenance\nQuarterly PM at every gate\n100% completed and documented\nPM checklist review\nEmergency response\nOn site within 4 hours\n95% of calls\nCall log / VA Police records\nSystem availability\n98% per gate per month\n98%\nMonthly report; platform data\nRemote alert review\nWithin 2 business hours\n95% of alerts\nPlatform audit log","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24527Q0083","place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"code":"DC","name":"District of Columbia"},"street":"Department of Veterans Affairs Washington DC VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"50 Irving Street NW"},"product_service_code":"J063"}],"due_at":"2026-12-15T15:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-24T04:44:58.053639Z","principal_notice_id":"45d08f759966476d9d29fd7f47d9cd6c","description":{"text":"SUMMARY\nThe Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services.\nThe Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required.\nNCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services.\nAnticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063\nPlease submit your capabilities statement and provide responses to all questions listed below.\nSOURCES SOUGHT NOTICE: 36C24527Q0083\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services\nfor the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the\nDC VAMC (if applicable)\n8. Confirmation that your organization has the capability and expertise to meet the performance\nrequirements while complying with applicable limitations in subcontracting by responding to the\nquestions below with your response:\n\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nIf you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nRespond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET.\nSend all responses to Billie.Pratt@va.gov\n\nSubject line on email:\n36C24527Q0083 Sources Sought Notice | Company Name\nSTATEMENT OF WORK\nParking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement\nDepartment of Veterans Affairs | Washington DC VA Medical Center\n50 Irving Street NW, Washington, DC 20422\nDraft dated October 27, 2026\n1. BACKGROUND\nThe Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access.\nVA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods.\n2. SCOPE OF WORK\nThe Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are \"or equal.\"\n3. LOCATIONS AND EXISTING CONDITIONS\nItem\nLocation / Type\nQuantity\nNotes\n1\nBarrier-arm gates (standard duty, 12 14 ft arm)\n17\nParking lots and service drives; includes separated Fisher House locations.\n2\nBarrier-arm gate (long arm, approx. 20 ft)\n1\nHeavy-duty operator; status reporting appropriate to hardware.\n3\nSlide gate Utility Building 8\n1\nReuse existing gate panel; convert from top track to bottom steel cantilever track.\n4\nLots 3B and 4B\nGates as installed (verify)\nRelocatable (forklift-movable) foundations and flexible wiring for planned two-way operation.\n\nTotal gate locations\n19\nContractor shall verify all locations and conditions during the mandatory site visit.\n\nExisting 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope.\n4. TECHNICAL REQUIREMENTS GATE SYSTEM\n4.1 Removal and Disposal\nRemove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads.\nRemoval and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan.\n4.2 Barrier Gate Operators\nCommercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable.\nIntegral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service.\nLED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system.\nAbove-ground radar (\"virtual loop\") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations.\nOne (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property.\n4.3 Slide Gate Utility Building 8\nConvert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required.\nFurnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable.\n4.4 Relocatable Foundations Lots 3B and 4B\nProvide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey.\n4.5 Remote Monitoring and Control\nProvide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release.\nThe dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available.\nAll life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices.\nCommunications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO.\n4.6 Event Cameras\nNineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events.\nCloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only.\n4.7 Cloud Platform, Information Security and Privacy\nThe hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled.\nAll data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract.\nUser access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication.\n4.8 Commissioning, Testing and Training\nSubmit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police.\nProvide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover.\n4.9 Warranty\nMinimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA.\n5. MANDATORY SUBCONTRACT JOHNSON CONTROLS, INC. (PIV BADGE READERS)\nThe VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply:\nSubcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty.\nReaders. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration.\nControllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to the PACS head-end as approved in writing by VA OIT/ISSO and VA Police Service.\nGate integration. Valid credential reads shall release the associated gate through a dry-contact interface coordinated between JCI and the prime; gate position and fault signals shall be made available to the PACS where supported.\nVA Police control. Upon completion, VA Police Service shall be able, from the C CURE workstation, to grant/revoke parking access by credential, set access levels and schedules by lot, lock down or hold open any gate, and view reader/door event history.\nPersonnel. JCI technicians shall be factory-certified on C CURE 9000/iSTAR and shall meet the background investigation and privileged-access requirements for work on a VA network-connected security system.\nService. For each option period exercised, the JCI subcontract shall include maintenance, firmware updates and repair of the readers and controllers installed under this contract.\n6. SERVICE AGREEMENT (BASE YEAR + FOUR OPTION YEARS)\nThe service agreement begins on the date of final acceptance of the installation and continues through the base period and each option period exercised by the Government. It covers all 19 gates and all equipment installed under this contract.\n6.1 Preventive Maintenance (PM)\nQuarterly PM at each gate per manufacturer schedules, including UL 325 entrapment-device testing, battery load testing, arm/flange/sensor inspection, radar detector alignment, camera and storage health, and firmware review. Provide a written PM checklist per gate to the COR within 5 business days of each PM cycle.\n6.2 Remote Monitoring\nAutomated 24/7 monitoring of gate fault, communication-loss and arm-displacement alerts. Contractor shall review each alert and begin remote troubleshooting within 2 hours (business hours) or by 9:00 a.m. the next business day (after hours), and notify the COR/VA Police of any gate not restored remotely.\n6.3 Corrective Maintenance and Response Times\nPriority\nCondition\nOn-site response\nRestore / make safe\nEmergency\nGate stuck closed blocking emergency vehicle route, or stuck open where VA Police declare a security need; safety hazard\n4 hours, 24/7/365\nMake safe / manual mode within 4 hours; restore within 24 hours\nUrgent\nGate inoperable but alternate access available\nNext business day\nWithin 2 business days (parts permitting)\nRoutine\nDegraded function (camera, LED, single sensor)\nWithin 3 business days\nWithin 5 business days\n\nFailures from normal wear, defects and equipment age are covered under the firm-fixed price (labor and parts) during warranty and under the service agreement thereafter.\nDamage from vehicle strikes, vandalism or acts of God is repaired under the Corrective Labor and Repair Parts CLINs at the fixed hourly rate and contract parts pricing, only after COR approval of a written estimate (emergency make-safe excepted).\n6.4 Subscriptions and Data Services\nAll cloud platform, monitoring, user, device and cellular data subscriptions required for system operation are included at a fixed annual price for each period. No surcharges, data overages or price increases are permitted except as priced in the option periods.\n6.5 Performance Standard\nMonthly system availability of at least 98% per gate (excluding approved PM windows and damage caused by others). The Contractor shall report monthly availability, alerts, response times and repairs to the COR.\n7. PERIOD OF PERFORMANCE AND SCHEDULE\nPeriod\nEstimated dates (adjust to award)\nContent\nBase Year\n02/01/2027 01/31/2028\nInstallation complete within 120 calendar days after Notice to Proceed; JCI reader integration; warranty; service agreement and subscriptions from acceptance\nOption Year 1\n02/01/2028 01/31/2029\nService agreement, subscriptions, JCI reader maintenance\nOption Year 2\n02/01/2029 01/31/2030\nSame as Option Year 1\nOption Year 3\n02/01/2030 01/31/2031\nSame as Option Year 1\nOption Year 4\n02/01/2031 01/31/2032\nSame as Option Year 1\n\nMilestone\nDue\nKick-off meeting (prime, JCI, COR, VA Police, OIT/ISSO, Safety)\nWithin 10 days of award\nSite survey report, submittals (product data, shop drawings, NDAA certifications, FedRAMP/ATO evidence), installation schedule & traffic plan\nWithin 30 days of award\nInstallation start (after submittal approval)\nPer approved schedule\nAcceptance testing and training\nWithin 120 days of NTP\nAs-builts, O&M manuals, credential turnover\nWithin 15 days after acceptance\n8. HOURS OF WORK, ACCESS AND COORDINATION\nNormal work hours: Monday Friday, 7:00 a.m. 3:30 p.m., excluding Federal holidays. Work outside these hours requires 48-hour advance COR approval. Emergency service is 24/7.\nContractor personnel shall check in with VA Police Service, wear VA-issued or company photo identification, and follow traffic-control plans meeting the MUTCD. Utility locates are required before any excavation or anchoring.\nThe Contractor shall maintain at least one functioning entry and exit per parking area during working hours or provide manual operation coordinated with VA Police.\n9. CONTRACTOR PERSONNEL SECURITY\nContractor and subcontractor personnel shall complete background investigations at the risk level designated by the VA Position Designation Tool (anticipated Tier 1 / Low Risk for gate technicians; higher for JCI personnel with privileged PACS access) per VA Directive and Handbook 0710.\nPersonnel requiring access to VA information or systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior training before access and annually thereafter.\n10. SAFETY, CODES AND STANDARDS\nUL 325 (Door, Drapery, Gate, Louver and Window Operators and Systems) and ASTM F2200 (Automated Vehicular Gate Construction)\nNFPA 70, National Electrical Code; OSHA 29 CFR 1910 and 1926; lock-out/tag-out\nFIPS 201-3 and GSA FIPS 201 Approved Products List; OMB M-19-17 (FICAM)\nVA Handbook 6500.6 (Contract Security); VA Directive 0730 (Security and Law Enforcement); VA Physical Security and Resiliency Design Manual\nFAR 52.204-25 (Section 889) and FAR 52.204-23/-27 prohibitions; Buy American / Trade Agreements as determined by the CO\nManufacturer installation instructions\n11. GOVERNMENT-FURNISHED ITEMS AND RESPONSIBILITIES\nExisting 120 VAC power at each location; access to sites with escort as required; VA Police PACS administrator support; VA OIT/ISSO review of PACS communications and cloud security documentation; designation of COR and alternate.\n12. DELIVERABLES\n#\nDeliverable\nDue\nTo\n1\nquotation / letter of commitment (with offer)\nWith quote\nCO\n2\nSite survey report; installation schedule; traffic plan\n30 days after award\nCOR\n3\nSubmittals incl. NDAA 889 and FIPS 201 APL certifications; FedRAMP/ATO evidence for cloud platform\n30 days after award\nCOR / ISSO\n4\nAcceptance Test Plan; completed test reports\n10 days before test / at test\nCOR\n5\nAs-built drawings, O&M manuals, programming & credential turnover\n15 days after acceptance\nCOR\n6\nQuarterly PM checklists per gate\n5 business days after each PM\nCOR\n7\nMonthly performance report (availability, alerts, response, repairs)\n10th day of following month\nCOR\n8\nWritten estimates for damage repairs\nBefore work (except make-safe)\nCOR\n13. PERFORMANCE REQUIREMENTS SUMMARY\nPerformance objective\nStandard\nAcceptable quality level\nSurveillance\nInstallation complete\nAll 19 gates and readers accepted\nWithin 120 days of NTP\nCOR inspection / test witness\nPreventive maintenance\nQuarterly PM at every gate\n100% completed and documented\nPM checklist review\nEmergency response\nOn site within 4 hours\n95% of calls\nCall log / VA Police records\nSystem availability\n98% per gate per month\n98%\nMonthly report; platform data\nRemote alert review\nWithin 2 business hours\n95% of alerts\nPlatform audit log","html":"SUMMARY\nThe Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services.\nThe Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required.\nNCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services.\nAnticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063\nPlease submit your capabilities statement and provide responses to all questions listed below.\nSOURCES SOUGHT NOTICE: 36C24527Q0083\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of services\nfor the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these services at the\nDC VAMC (if applicable)\n8. Confirmation that your organization has the capability and expertise to meet the performance\nrequirements while complying with applicable limitations in subcontracting by responding to the\nquestions below with your response:\n\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nIf you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?\n\nResponse Instructions:\nRespond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET. \nSend all responses to Billie.Pratt@va.gov \n\nSubject line on email: \n36C24527Q0083   Sources Sought Notice | Company Name\nSTATEMENT OF WORK\nParking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement \nDepartment of Veterans Affairs  |  Washington DC VA Medical Center\n50 Irving Street NW, Washington, DC 20422\nDraft dated October 27, 2026\n1. BACKGROUND\nThe Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access.\nVA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods.\n2. SCOPE OF WORK\nThe Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are \"or equal.\"\n3. LOCATIONS AND EXISTING CONDITIONS\nItem\nLocation / Type\nQuantity\nNotes\n1\nBarrier-arm gates (standard duty, 12 14 ft arm)\n17\nParking lots and service drives; includes separated Fisher House locations.\n2\nBarrier-arm gate (long arm, approx. 20 ft)\n1\nHeavy-duty operator; status reporting appropriate to hardware.\n3\nSlide gate   Utility Building 8\n1\nReuse existing gate panel; convert from top track to bottom steel cantilever track.\n4\nLots 3B and 4B\nGates as installed (verify)\nRelocatable (forklift-movable) foundations and flexible wiring for planned two-way operation.\n\nTotal gate locations\n19\nContractor shall verify all locations and conditions during the mandatory site visit.\n\nExisting 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope.\n4. TECHNICAL REQUIREMENTS   GATE SYSTEM\n4.1 Removal and Disposal\nRemove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads.\nRemoval and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan.\n4.2 Barrier Gate Operators\nCommercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable.\nIntegral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service.\nLED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system.\nAbove-ground radar (\"virtual loop\") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations.\nOne (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property.\n4.3 Slide Gate   Utility Building 8\nConvert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required.\nFurnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable.\n4.4 Relocatable Foundations   Lots 3B and 4B\nProvide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey.\n4.5 Remote Monitoring and Control\nProvide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release.\nThe dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available.\nAll life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices.\nCommunications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO.\n4.6 Event Cameras\nNineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events.\nCloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only.\n4.7 Cloud Platform, Information Security and Privacy\nThe hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled.\nAll data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract.\nUser access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication.\n4.8 Commissioning, Testing and Training\nSubmit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police.\nProvide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover.\n4.9 Warranty\nMinimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA.\n5. MANDATORY SUBCONTRACT   JOHNSON CONTROLS, INC. (PIV BADGE READERS)\nThe VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply:\nSubcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty.\nReaders. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration.\nControllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to the PACS head-end as approved in writing by VA OIT/ISSO and VA Police Service.\nGate integration. Valid credential reads shall release the associated gate through a dry-contact interface coordinated between JCI and the prime; gate position and fault signals shall be made available to the PACS where supported.\nVA Police control. Upon completion, VA Police Service shall be able, from the C CURE workstation, to grant/revoke parking access by credential, set access levels and schedules by lot, lock down or hold open any gate, and view reader/door event history.\nPersonnel. JCI technicians shall be factory-certified on C CURE 9000/iSTAR and shall meet the background investigation and privileged-access requirements for work on a VA network-connected security system.\nService. For each option period exercised, the JCI subcontract shall include maintenance, firmware updates and repair of the readers and controllers installed under this contract.\n6. SERVICE AGREEMENT (BASE YEAR + FOUR OPTION YEARS)\nThe service agreement begins on the date of final acceptance of the installation and continues through the base period and each option period exercised by the Government. It covers all 19 gates and all equipment installed under this contract.\n6.1 Preventive Maintenance (PM)\nQuarterly PM at each gate per manufacturer schedules, including UL 325 entrapment-device testing, battery load testing, arm/flange/sensor inspection, radar detector alignment, camera and storage health, and firmware review. Provide a written PM checklist per gate to the COR within 5 business days of each PM cycle.\n6.2 Remote Monitoring\nAutomated 24/7 monitoring of gate fault, communication-loss and arm-displacement alerts. Contractor shall review each alert and begin remote troubleshooting within 2 hours (business hours) or by 9:00 a.m. the next business day (after hours), and notify the COR/VA Police of any gate not restored remotely.\n6.3 Corrective Maintenance and Response Times\nPriority\nCondition\nOn-site response\nRestore / make safe\nEmergency\nGate stuck closed blocking emergency vehicle route, or stuck open where VA Police declare a security need; safety hazard\n4 hours, 24/7/365\nMake safe / manual mode within 4 hours; restore within 24 hours\nUrgent\nGate inoperable but alternate access available\nNext business day\nWithin 2 business days (parts permitting)\nRoutine\nDegraded function (camera, LED, single sensor)\nWithin 3 business days\nWithin 5 business days\n\nFailures from normal wear, defects and equipment age are covered under the firm-fixed price (labor and parts) during warranty and under the service agreement thereafter.\nDamage from vehicle strikes, vandalism or acts of God is repaired under the Corrective Labor and Repair Parts CLINs at the fixed hourly rate and contract parts pricing, only after COR approval of a written estimate (emergency make-safe excepted).\n6.4 Subscriptions and Data Services\nAll cloud platform, monitoring, user, device and cellular data subscriptions required for system operation are included at a fixed annual price for each period. No surcharges, data overages or price increases are permitted except as priced in the option periods.\n6.5 Performance Standard\nMonthly system availability of at least 98% per gate (excluding approved PM windows and damage caused by others). The Contractor shall report monthly availability, alerts, response times and repairs to the COR.\n7. PERIOD OF PERFORMANCE AND SCHEDULE\nPeriod\nEstimated dates (adjust to award)\nContent\nBase Year\n02/01/2027   01/31/2028\nInstallation complete within 120 calendar days after Notice to Proceed; JCI reader integration; warranty; service agreement and subscriptions from acceptance\nOption Year 1\n02/01/2028   01/31/2029\nService agreement, subscriptions, JCI reader maintenance\nOption Year 2\n02/01/2029   01/31/2030\nSame as Option Year 1\nOption Year 3\n02/01/2030   01/31/2031\nSame as Option Year 1\nOption Year 4\n02/01/2031   01/31/2032\nSame as Option Year 1\n\nMilestone\nDue\nKick-off meeting (prime, JCI, COR, VA Police, OIT/ISSO, Safety)\nWithin 10 days of award\nSite survey report, submittals (product data, shop drawings, NDAA certifications, FedRAMP/ATO evidence), installation schedule & traffic plan\nWithin 30 days of award\nInstallation start (after submittal approval)\nPer approved schedule\nAcceptance testing and training\nWithin 120 days of NTP\nAs-builts, O&M manuals, credential turnover\nWithin 15 days after acceptance\n8. HOURS OF WORK, ACCESS AND COORDINATION\nNormal work hours: Monday Friday, 7:00 a.m. 3:30 p.m., excluding Federal holidays. Work outside these hours requires 48-hour advance COR approval. Emergency service is 24/7.\nContractor personnel shall check in with VA Police Service, wear VA-issued or company photo identification, and follow traffic-control plans meeting the MUTCD. Utility locates are required before any excavation or anchoring.\nThe Contractor shall maintain at least one functioning entry and exit per parking area during working hours or provide manual operation coordinated with VA Police.\n9. CONTRACTOR PERSONNEL SECURITY\nContractor and subcontractor personnel shall complete background investigations at the risk level designated by the VA Position Designation Tool (anticipated Tier 1 / Low Risk for gate technicians; higher for JCI personnel with privileged PACS access) per VA Directive and Handbook 0710.\nPersonnel requiring access to VA information or systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior training before access and annually thereafter.\n10. SAFETY, CODES AND STANDARDS\nUL 325 (Door, Drapery, Gate, Louver and Window Operators and Systems) and ASTM F2200 (Automated Vehicular Gate Construction)\nNFPA 70, National Electrical Code; OSHA 29 CFR 1910 and 1926; lock-out/tag-out\nFIPS 201-3 and GSA FIPS 201 Approved Products List; OMB M-19-17 (FICAM)\nVA Handbook 6500.6 (Contract Security); VA Directive 0730 (Security and Law Enforcement); VA Physical Security and Resiliency Design Manual\nFAR 52.204-25 (Section 889) and FAR 52.204-23/-27 prohibitions; Buy American / Trade Agreements as determined by the CO\nManufacturer installation instructions\n11. GOVERNMENT-FURNISHED ITEMS AND RESPONSIBILITIES\nExisting 120 VAC power at each location; access to sites with escort as required; VA Police PACS administrator support; VA OIT/ISSO review of PACS communications and cloud security documentation; designation of COR and alternate.\n12. DELIVERABLES\n#\nDeliverable\nDue\nTo\n1\nquotation / letter of commitment (with offer)\nWith quote\nCO\n2\nSite survey report; installation schedule; traffic plan\n30 days after award\nCOR\n3\nSubmittals incl. NDAA 889 and FIPS 201 APL certifications; FedRAMP/ATO evidence for cloud platform\n30 days after award\nCOR / ISSO\n4\nAcceptance Test Plan; completed test reports\n10 days before test / at test\nCOR\n5\nAs-built drawings, O&M manuals, programming & credential turnover\n15 days after acceptance\nCOR\n6\nQuarterly PM checklists per gate\n5 business days after each PM\nCOR\n7\nMonthly performance report (availability, alerts, response, repairs)\n10th day of following month\nCOR\n8\nWritten estimates for damage repairs\nBefore work (except make-safe)\nCOR\n13. PERFORMANCE REQUIREMENTS SUMMARY\nPerformance objective\nStandard\nAcceptable quality level\nSurveillance\nInstallation complete\nAll 19 gates and readers accepted\nWithin 120 days of NTP\nCOR inspection / test witness\nPreventive maintenance\nQuarterly PM at every gate\n100% completed and documented\nPM checklist review\nEmergency response\nOn site within 4 hours\n95% of calls\nCall log / VA Police records\nSystem availability\n  98% per gate per month\n  98%\nMonthly report; platform data\nRemote alert review\nWithin 2 business hours\n95% of alerts\nPlatform audit log","origin":"detail"},"contacts":[{"name":"Bill Pratt","role":"primary","email":"Billie.Pratt@va.gov","phone":"410-642-2411","title":"Contracting Officer"}],"place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"code":"DC","name":"District of Columbia"},"street":"Department of Veterans Affairs Washington DC VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"50 Irving Street NW"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["561621"],"award":{"awardee":{}},"attachments":[{"resource_id":"38e75ad6e51f459c8dde2fdb5cec0e3a","name":"36C24527Q0083.docx","kind":"file","mime_type":".docx","size_bytes":39738,"posted_at":"2026-11-23T17:49:27.498Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/38e75ad6e51f459c8dde2fdb5cec0e3a/download","mirrored":false},{"resource_id":"0c9e51dd8456413fa0536efe2522820a","name":"VA","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-23T17:49:27.498Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0058","latest_notice_id":"740a0ce07bb64f898a0cbfb567da2a5c","title":"F014--TREE REMOVAL VAMC MARTINSBURG","solicitation_number":"36C24527Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561730","psc":"F014","set_aside":null,"state":"WV","county":"54003","county_name":"Berkeley County","city":"5452060","city_name":"Martinsburg","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"95476727Q1104","latest_notice_id":"885eda7acccd404ba1a1a20ab66143e1","title":"Maintenance and Repair Service for Retractable Security Bollards and Barriers","solicitation_number":"95476727Q1104","notice_type":"o","first_type":"o","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-12-01T22:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-456","dept_name":"UNITED STATES HOLOCAUST MEMORIAL MUSEUM","sub_key":"s-9531","sub_name":"UNITED STATES HOLOCAUST MEMORIAL MUSEUM","office_key":"o-954767","office_name":"USHMM PROCUREMENT DIVISION","naics":"561621","psc":"J063","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"70RFP226QEC000005","latest_notice_id":"9258c1810984437c9b3300dd20d13b95","title":"Corrective and Preventative Maintenance of Electronic Security Systems at the Ronald Reagan Building","solicitation_number":"70RFP226QEC000005","notice_type":"o","first_type":"p","first_posted":"2026-04-27","last_posted":"2026-11-10","notices":8,"due_at":"2026-12-11T18:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7001","sub_name":"OFFICE OF PROCUREMENT OPERATIONS","office_key":"o-70RFP2","office_name":"FPS EAST CCG DIV 2 ACQ DIV","naics":"561621","psc":"J063","set_aside":"WOSB","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"IHSSS11182026","latest_notice_id":"38800d0d6ad64cecabc18acf586542a5","title":"Fire Monitoring, Inspections, Maintenance, and Remediation Services","solicitation_number":"IHSSS11182026","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"561621","psc":"6350","set_aside":"ISBEE","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":26,"indexable":true}