{"canonical":"https://sealedbidder.com/opportunities/36c24527q0061","key":"36C24527Q0061","url":"https://sealedbidder.com/opportunities/36c24527q0061","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-11-30T13:00:00Z","first_posted":"2026-11-12","last_posted":"2026-11-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","place_state":"MD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"6e82689662f44358819516314429756b","title":"J065-- HVAC upgrades at VA Loch Raven location","solicitation_number":"36C24527Q0061","notice_type":"p","base_type":"p","posted":"2026-11-12","posted_at":"2026-11-12T15:19:12.551Z","due_at":"2026-12-14T13:00:00Z","due_date":"2026-12-14","cancelled":false,"archived":false,"archive_date":"2027-01-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6e82689662f44358819516314429756b/view","enriched":true,"history":[{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}]},{"notice_id":"fc29e3904eb3405bab37833cd265b531","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","base_type":"p","posted":"2026-11-12","posted_at":"2026-11-12T16:12:59.205Z","due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","cancelled":false,"archived":false,"archive_date":"2027-01-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fc29e3904eb3405bab37833cd265b531/view","enriched":true,"history":[{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}]},{"notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","base_type":"o","posted":"2026-11-18","posted_at":"2026-11-18T21:40:47.942Z","due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","cancelled":false,"archived":false,"archive_date":"2027-01-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0db5662de5914b458655bed9898980cf/view","enriched":true,"history":[{"index":3,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-18T21:40:47.942Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0db5662de5914b458655bed9898980cf","solicitation_number":"36C24527Q0061","parent_opportunity_id":"fc29e3904eb3405bab37833cd265b531","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}]}],"latest_notice_id":"0db5662de5914b458655bed9898980cf","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-11-12","posted_at":"2026-11-12T15:19:12.551Z","created_at":"2026-11-12T15:19:10.270Z","modified_at":"2026-11-12T15:19:12.551Z","response_deadline":{"raw":"2026-12-14T08:00:00-05:00","utc":"2026-12-14T13:00:00Z","date":"2026-12-14","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6e82689662f44358819516314429756b/view"},"naics":{"codes":["561210"],"primary":"561210"},"title":"J065-- HVAC upgrades at VA Loch Raven location","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-13","archive_type":"auto_custom"},"history":[{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}],"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","phone":"410-637-1513","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"6e82689662f44358819516314429756b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"6e82689662f44358819516314429756b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T05:53:43.851548220Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"7ba2d1e3bb2c190af43f4e83137c445a-27\"","fetched_at":"2026-11-13T05:16:19.555733301Z","row_sha256":"6e323c390d061788df79c28e04fa45863f53a4bb70244ac7ef500442cde41df9","last_modified":"2026-11-13T04:30:18Z"},"updated_at":"2026-11-13T05:53:43.851548220Z","first_seen_at":"2026-11-13T05:16:19.555733301Z"},"description":{"html":"The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus.\n\nPrimary Deliverables and Project Requirements\nCovid Ward 2nd floor B wing\nUpgrade exhaust fans\nAir Handling Unit (AHU-B) located in attic\nReplace and upgrade EF-1A and EF-1B for higher CFM outputs\nInstall heat tracing for chillers \nWiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. \nAssess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD.\nInstall a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA.\nKitchen basement\nReplace cooling coil(s) \nAHU-E located in attic.\nReplace fan motor\nAHU-E located in attic. AHU has one fan.\nNew motor must be rated for and capable of sustaining a fan speed of 60Hz.\nReplace Variable Frequency Drive (VFD)\nVFD located in the attic and attached to the AHU\nReplace VFD in kind with Manufacturer (ABB)\nControls Integration & Coordination\nVA has an existing contract with Johnson Controls International (JCI). \nThe contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. \nContractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis.\n\nTesting Adjusting & Balancing (TAB)\nTAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance\nContractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB.\nA report on the TAB results must be delivered to the COR.\nTAB report will be reviewed and approved by the VA prior to contractual closeout and final payment\nWarranty, Operations & Manuals (O&Ms) and Shop Drawings\nContractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA.\nWarranty is based on workmanship, material and equipment.\nDuration of warranty starts after acceptance and use of new equipment & components \nO&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA.\nAll O&M documents must be received by the VA prior to contractual closeout and final payment\nContractor shall provide training to the VA.\nShop Drawings\nAll layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission.\nAssumptions \nContractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment.\nLine items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status.  Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s).\nPay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance.\nAdditional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO.  \nAny additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition.\nSupplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc.\nVA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work\nStandard Inclusions & General Compliance\nContractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to:\nInfection Control Risk Assessment (ICRA)  \nPre-Construction Risk Assessment (PCRA)\nHot or burn work \nConfined space entry work (if applicable) \nLock out tag out (LOTO) procedures\nPPE\nParking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director.\nParking outside the campus boundary is not in the VA s jurisdiction \nThe contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities.\nUtility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure.\n\nPeriod of performance is 90 calendar days.","text":"The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus.\n\nPrimary Deliverables and Project Requirements\nCovid Ward 2nd floor B wing\nUpgrade exhaust fans\nAir Handling Unit (AHU-B) located in attic\nReplace and upgrade EF-1A and EF-1B for higher CFM outputs\nInstall heat tracing for chillers\nWiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road.\nAssess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD.\nInstall a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA.\nKitchen basement\nReplace cooling coil(s)\nAHU-E located in attic.\nReplace fan motor\nAHU-E located in attic. AHU has one fan.\nNew motor must be rated for and capable of sustaining a fan speed of 60Hz.\nReplace Variable Frequency Drive (VFD)\nVFD located in the attic and attached to the AHU\nReplace VFD in kind with Manufacturer (ABB)\nControls Integration & Coordination\nVA has an existing contract with Johnson Controls International (JCI).\nThe contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work.\nContractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis.\n\nTesting Adjusting & Balancing (TAB)\nTAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance\nContractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB.\nA report on the TAB results must be delivered to the COR.\nTAB report will be reviewed and approved by the VA prior to contractual closeout and final payment\nWarranty, Operations & Manuals (O&Ms) and Shop Drawings\nContractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA.\nWarranty is based on workmanship, material and equipment.\nDuration of warranty starts after acceptance and use of new equipment & components\nO&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA.\nAll O&M documents must be received by the VA prior to contractual closeout and final payment\nContractor shall provide training to the VA.\nShop Drawings\nAll layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission.\nAssumptions\nContractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment.\nLine items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s).\nPay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance.\nAdditional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO.\nAny additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition.\nSupplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc.\nVA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work\nStandard Inclusions & General Compliance\nContractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to:\nInfection Control Risk Assessment (ICRA)\nPre-Construction Risk Assessment (PCRA)\nHot or burn work\nConfined space entry work (if applicable)\nLock out tag out (LOTO) procedures\nPPE\nParking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director.\nParking outside the campus boundary is not in the VA s jurisdiction\nThe contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities.\nUtility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure.\n\nPeriod of performance is 90 calendar days.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24527Q0061","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N Greene St"},"product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-12","posted_at":"2026-11-12T16:12:59.205Z","created_at":"2026-11-12T16:12:56.945Z","modified_at":"2026-11-12T16:12:59.205Z","response_deadline":{"raw":"2026-11-30T08:00:00-05:00","utc":"2026-11-30T13:00:00Z","date":"2026-11-30","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fc29e3904eb3405bab37833cd265b531/view"},"naics":{"codes":["561210"],"primary":"561210"},"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-29","archive_type":"auto_custom"},"history":[{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}],"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"fc29e3904eb3405bab37833cd265b531","lineage_id":"6e82689662f44358819516314429756b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T07:00:15.865097879Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"7ba2d1e3bb2c190af43f4e83137c445a-27\"","fetched_at":"2026-11-13T05:16:19.555733301Z","row_sha256":"455a9a1f73ec2c14949c93324f327afc392979eea68cba18e4395085f4f2370f","last_modified":"2026-11-13T04:30:18Z"},"updated_at":"2026-11-13T07:00:15.865097879Z","first_seen_at":"2026-11-13T05:16:19.555733301Z"},"description":{"html":"Presolicitation Notice\n\nPresolicitation Notice\n\nPage 5 of 5\nPresolicitation Notice\n*=Required Field\nPresolicitation Notice\n\nPage 1 of 5\nThe contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus.\n\nPrimary Deliverables and Project Requirements\nCovid Ward 2nd floor B wing\nUpgrade exhaust fans\nAir Handling Unit (AHU-B) located in attic\nReplace and upgrade EF-1A and EF-1B for higher CFM outputs\nInstall heat tracing for chillers \nWiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. \nAssess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD.\nInstall a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA.\nKitchen basement\nReplace cooling coil(s) \nAHU-E located in attic.\nReplace fan motor\nAHU-E located in attic. AHU has one fan.\nNew motor must be rated for and capable of sustaining a fan speed of 60Hz.\nReplace Variable Frequency Drive (VFD)\nVFD located in the attic and attached to the AHU\nReplace VFD in kind with Manufacturer (ABB)\nControls Integration & Coordination\nVA has an existing contract with Johnson Controls International (JCI). \nThe contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. \nContractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis.\n\nTesting Adjusting & Balancing (TAB)\nTAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance\nContractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB.\nA report on the TAB results must be delivered to the COR.\nTAB report will be reviewed and approved by the VA prior to contractual closeout and final payment\nWarranty, Operations & Manuals (O&Ms) and Shop Drawings\nContractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA.\nWarranty is based on workmanship, material and equipment.\nDuration of warranty starts after acceptance and use of new equipment & components \nO&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA.\nAll O&M documents must be received by the VA prior to contractual closeout and final payment\nContractor shall provide training to the VA.\nShop Drawings\nAll layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission.\nAssumptions \nContractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment.\nLine items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status.  Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s).\nPay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance.\nAdditional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO.  \nAny additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition.\nSupplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc.\nVA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work\nStandard Inclusions & General Compliance\nContractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to:\nInfection Control Risk Assessment (ICRA)  \nPre-Construction Risk Assessment (PCRA)\nHot or burn work \nConfined space entry work (if applicable) \nLock out tag out (LOTO) procedures\nPPE\nParking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director.\nParking outside the campus boundary is not in the VA s jurisdiction \nThe contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities.\nUtility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure.\n\nPeriod of performance is 90 calendar days.","text":"Presolicitation Notice\n\nPresolicitation Notice\n\nPage 5 of 5\nPresolicitation Notice\n*=Required Field\nPresolicitation Notice\n\nPage 1 of 5\nThe contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus.\n\nPrimary Deliverables and Project Requirements\nCovid Ward 2nd floor B wing\nUpgrade exhaust fans\nAir Handling Unit (AHU-B) located in attic\nReplace and upgrade EF-1A and EF-1B for higher CFM outputs\nInstall heat tracing for chillers\nWiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road.\nAssess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD.\nInstall a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA.\nKitchen basement\nReplace cooling coil(s)\nAHU-E located in attic.\nReplace fan motor\nAHU-E located in attic. AHU has one fan.\nNew motor must be rated for and capable of sustaining a fan speed of 60Hz.\nReplace Variable Frequency Drive (VFD)\nVFD located in the attic and attached to the AHU\nReplace VFD in kind with Manufacturer (ABB)\nControls Integration & Coordination\nVA has an existing contract with Johnson Controls International (JCI).\nThe contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work.\nContractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis.\n\nTesting Adjusting & Balancing (TAB)\nTAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance\nContractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB.\nA report on the TAB results must be delivered to the COR.\nTAB report will be reviewed and approved by the VA prior to contractual closeout and final payment\nWarranty, Operations & Manuals (O&Ms) and Shop Drawings\nContractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA.\nWarranty is based on workmanship, material and equipment.\nDuration of warranty starts after acceptance and use of new equipment & components\nO&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA.\nAll O&M documents must be received by the VA prior to contractual closeout and final payment\nContractor shall provide training to the VA.\nShop Drawings\nAll layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission.\nAssumptions\nContractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment.\nLine items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s).\nPay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance.\nAdditional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO.\nAny additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition.\nSupplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc.\nVA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work\nStandard Inclusions & General Compliance\nContractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to:\nInfection Control Risk Assessment (ICRA)\nPre-Construction Risk Assessment (PCRA)\nHot or burn work\nConfined space entry work (if applicable)\nLock out tag out (LOTO) procedures\nPPE\nParking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director.\nParking outside the campus boundary is not in the VA s jurisdiction\nThe contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities.\nUtility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure.\n\nPeriod of performance is 90 calendar days.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24527Q0061","product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-18","posted_at":"2026-11-18T21:40:47.942Z","created_at":"2026-11-18T21:38:22.377Z","modified_at":"2026-11-18T21:40:47.945Z","response_deadline":{"raw":"2026-11-30T08:00:00-05:00","utc":"2026-11-30T13:00:00Z","date":"2026-11-30","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0db5662de5914b458655bed9898980cf/view"},"naics":{"codes":["561210"],"primary":"561210"},"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-18T21:40:47.942Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0db5662de5914b458655bed9898980cf","solicitation_number":"36C24527Q0061","parent_opportunity_id":"fc29e3904eb3405bab37833cd265b531","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":2,"title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T16:12:59.205Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fc29e3904eb3405bab37833cd265b531","solicitation_number":"36C24527Q0061","related_opportunity_id":"6e82689662f44358819516314429756b"},{"index":1,"title":"J065-- HVAC upgrades at VA Loch Raven location","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-12T15:19:12.551Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"6e82689662f44358819516314429756b","solicitation_number":"36C24527Q0061"}],"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0db5662de5914b458655bed9898980cf","lineage_id":"fc29e3904eb3405bab37833cd265b531","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T06:26:19.015463300Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"6ef056520f5b764db7a4b6f45118f236-27\"","fetched_at":"2026-11-19T04:37:24.575886376Z","row_sha256":"3a432c1de137e4d1430905cda787d7e43817737bbb33c3ae20928431550c17b4","last_modified":"2026-11-19T04:30:19Z"},"updated_at":"2026-11-19T06:26:19.015463300Z","first_seen_at":"2026-11-19T04:37:24.575886376Z"},"description":{"html":"<p>Presolicitation Notice Presolicitation Notice Page 5 of 5 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 5 The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus. Primary Deliverables and Project Requirements Covid Ward 2nd floor B wing Upgrade exhaust fans Air Handling Unit (AHU-B) located in attic Replace and upgrade EF-1A and EF-1B for higher CFM outputs Install heat tracing for chillers Wiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. Assess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD. Install a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA. Kitchen basement Replace cooling coil(s) AHU-E located in attic. Replace fan motor AHU-E located in attic. AHU has one fan. New motor must be rated for and capable of sustaining a fan speed of 60Hz. Replace Variable Frequency Drive (VFD) VFD located in the attic and attached to the AHU Replace VFD in kind with Manufacturer (ABB) Controls Integration &amp; Coordination VA has an existing contract with Johnson Controls International (JCI). The contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. Contractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis. Testing Adjusting &amp; Balancing (TAB) TAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance Contractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB. A report on the TAB results must be delivered to the COR. TAB report will be reviewed and approved by the VA prior to contractual closeout and final payment Warranty, Operations &amp; Manuals (O&amp;Ms) and Shop Drawings Contractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA. Warranty is based on workmanship, material and equipment. Duration of warranty starts after acceptance and use of new equipment &amp; components O&amp;Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA. All O&amp;M documents must be received by the VA prior to contractual closeout and final payment Contractor shall provide training to the VA. Shop Drawings All layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission. Assumptions Contractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment. Line items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s). Pay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance. Additional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO. Any additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition. Supplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal &amp; state guidelines, applicable codes, etc. VA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work Standard Inclusions &amp; General Compliance Contractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to: Infection Control Risk Assessment (ICRA) Pre-Construction Risk Assessment (PCRA) Hot or burn work Confined space entry work (if applicable) Lock out tag out (LOTO) procedures PPE Parking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director. Parking outside the campus boundary is not in the VA s jurisdiction The contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities. Utility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure. Period of performance is 90 calendar days.</p>","text":"Presolicitation Notice Presolicitation Notice Page 5 of 5 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 5 The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus. Primary Deliverables and Project Requirements Covid Ward 2nd floor B wing Upgrade exhaust fans Air Handling Unit (AHU-B) located in attic Replace and upgrade EF-1A and EF-1B for higher CFM outputs Install heat tracing for chillers Wiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. Assess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD. Install a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA. Kitchen basement Replace cooling coil(s) AHU-E located in attic. Replace fan motor AHU-E located in attic. AHU has one fan. New motor must be rated for and capable of sustaining a fan speed of 60Hz. Replace Variable Frequency Drive (VFD) VFD located in the attic and attached to the AHU Replace VFD in kind with Manufacturer (ABB) Controls Integration & Coordination VA has an existing contract with Johnson Controls International (JCI). The contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. Contractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis. Testing Adjusting & Balancing (TAB) TAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance Contractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB. A report on the TAB results must be delivered to the COR. TAB report will be reviewed and approved by the VA prior to contractual closeout and final payment Warranty, Operations & Manuals (O&Ms) and Shop Drawings Contractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA. Warranty is based on workmanship, material and equipment. Duration of warranty starts after acceptance and use of new equipment & components O&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA. All O&M documents must be received by the VA prior to contractual closeout and final payment Contractor shall provide training to the VA. Shop Drawings All layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission. Assumptions Contractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment. Line items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s). Pay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance. Additional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO. Any additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition. Supplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc. VA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work Standard Inclusions & General Compliance Contractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to: Infection Control Risk Assessment (ICRA) Pre-Construction Risk Assessment (PCRA) Hot or burn work Confined space entry work (if applicable) Lock out tag out (LOTO) procedures PPE Parking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director. Parking outside the campus boundary is not in the VA s jurisdiction The contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities. Utility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure. Period of performance is 90 calendar days.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24527Q0061","product_service_code":"J065"}],"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-19T04:41:36.780616Z","principal_notice_id":"0db5662de5914b458655bed9898980cf","description":{"text":"Presolicitation Notice Presolicitation Notice Page 5 of 5 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 5 The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus. Primary Deliverables and Project Requirements Covid Ward 2nd floor B wing Upgrade exhaust fans Air Handling Unit (AHU-B) located in attic Replace and upgrade EF-1A and EF-1B for higher CFM outputs Install heat tracing for chillers Wiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. Assess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD. Install a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA. Kitchen basement Replace cooling coil(s) AHU-E located in attic. Replace fan motor AHU-E located in attic. AHU has one fan. New motor must be rated for and capable of sustaining a fan speed of 60Hz. Replace Variable Frequency Drive (VFD) VFD located in the attic and attached to the AHU Replace VFD in kind with Manufacturer (ABB) Controls Integration & Coordination VA has an existing contract with Johnson Controls International (JCI). The contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. Contractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis. Testing Adjusting & Balancing (TAB) TAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance Contractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB. A report on the TAB results must be delivered to the COR. TAB report will be reviewed and approved by the VA prior to contractual closeout and final payment Warranty, Operations & Manuals (O&Ms) and Shop Drawings Contractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA. Warranty is based on workmanship, material and equipment. Duration of warranty starts after acceptance and use of new equipment & components O&Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA. All O&M documents must be received by the VA prior to contractual closeout and final payment Contractor shall provide training to the VA. Shop Drawings All layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission. Assumptions Contractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment. Line items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s). Pay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance. Additional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO. Any additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition. Supplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal & state guidelines, applicable codes, etc. VA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work Standard Inclusions & General Compliance Contractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to: Infection Control Risk Assessment (ICRA) Pre-Construction Risk Assessment (PCRA) Hot or burn work Confined space entry work (if applicable) Lock out tag out (LOTO) procedures PPE Parking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director. Parking outside the campus boundary is not in the VA s jurisdiction The contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities. Utility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure. Period of performance is 90 calendar days.","html":"<p>Presolicitation Notice Presolicitation Notice Page 5 of 5 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 5 The contractor will provide all material, labor, equipment, and supervision necessary to complete the above-named project at the VA Maryland Health Care System (VAMHCS), Building 1 Community Living Center (CLC) of the Loch Raven Campus. Primary Deliverables and Project Requirements Covid Ward 2nd floor B wing Upgrade exhaust fans Air Handling Unit (AHU-B) located in attic Replace and upgrade EF-1A and EF-1B for higher CFM outputs Install heat tracing for chillers Wiring and junction box located in room G-15. Chiller located outside CLC in the pit behind the service road. Assess current heat tracing for chill water line. Complete and terminate existing heat tracing wiring to an emergency electrical panel in G-17 in coordination with the VA. Panel selection is TBD. Install a 20-amp GFPE circuit breaker for the heat tracing to the panel selected by the VA. Kitchen basement Replace cooling coil(s) AHU-E located in attic. Replace fan motor AHU-E located in attic. AHU has one fan. New motor must be rated for and capable of sustaining a fan speed of 60Hz. Replace Variable Frequency Drive (VFD) VFD located in the attic and attached to the AHU Replace VFD in kind with Manufacturer (ABB) Controls Integration &amp; Coordination VA has an existing contract with Johnson Controls International (JCI). The contractor shall coordinate with the COR and Facility Maintenance to satisfy necessities for the facility s existing Building Automation System (BAS) controls corresponding to all new work. Contractor will replace/reinstall or provide new hardware or connections for BAS monitoring when required to complete BAS programming or integration. This can include control wiring, modulators, switches, routing, existing equipment etc. These requirements are determined on a case-by-case basis. Testing Adjusting &amp; Balancing (TAB) TAB shall occur after HVAC modifications are made. It must be performed by a certified vendor/contractor per TABB and/or other ANAB accredited programs for standard industry HVAC system performance compliance Contractor shall provide notice to and request attendance of the COR and/or other COR-approved VA representation prior to TAB. A report on the TAB results must be delivered to the COR. TAB report will be reviewed and approved by the VA prior to contractual closeout and final payment Warranty, Operations &amp; Manuals (O&amp;Ms) and Shop Drawings Contractor and/or subcontractor shall provide a warranty letter including point of contact, to the VA. Warranty is based on workmanship, material and equipment. Duration of warranty starts after acceptance and use of new equipment &amp; components O&amp;Ms for all new equipment and other components requiring preventative maintenance shall be provided to the VA. All O&amp;M documents must be received by the VA prior to contractual closeout and final payment Contractor shall provide training to the VA. Shop Drawings All layout changes and new equipment shall be updated in as-builts, shop drawings, manufacturer diagrams, details, where applicable. Due to the nature of the contract, this requirement will be determined based on off application by the COR at completion of work. If no applicable documents are required, then the COR will opt for omission. Assumptions Contractor to provide a cost/unit for each of the deliverable items above and use the total amounts provided for their proposal. Contractor to track the quantities used on their pay applications with any amounts left over being returned to the government after final payment. All deliverables must be received by the VA prior to final payment. Line items will be tracked in every pay application. Financial progress for a line item will be cross-referenced with the corresponding item s physical progress and/or completion status. Misrepresentation of a line item s financial progress may result in rejection from the COR and require the contractor to resubmit the pay application with revision(s). Pay applications must be submitted with a total amount not to exceed the Purchase Order (PO) balance. A contract modification from the Contracting Officer (CO) is required for payment application submissions exceeding the PO balance. Additional work outside of the contract and contractual supplement documents (provided drawings, as-builts, details, existing product information, etc) require authorization and written execution from the CO. Any additional work (quantified via labor, material or equipment) performed/provided by the contractor without guidance from the VA or direction from the CO shall not be included in payment applications. The contractor is committed to working at their own expense and risk under this condition. Supplemental contractual and scope of work include existing as-builts, details and compliance for VA guidelines, federal &amp; state guidelines, applicable codes, etc. VA can provide the contractor with additional available drawings and other documentation. These are considered items pertaining to the original contract s scope of work Standard Inclusions &amp; General Compliance Contractor is responsible for cleaning the work area of trash regardless of if it is their trash or not. This includes areas that other entities may have access to like the attic and mechanical spaces. Contractor is responsible for stewardship of work area and compliance with VA medical facility guidelines. Contractor will adhere to VA-granted permitting requirements and industry standard safety practices including but not limited to: Infection Control Risk Assessment (ICRA) Pre-Construction Risk Assessment (PCRA) Hot or burn work Confined space entry work (if applicable) Lock out tag out (LOTO) procedures PPE Parking at the Loch Raven campus is limited and contractors are subject to facility guidelines for locations of contractor vehicles. Guidance for contractor parking is enforced by the COR, Facility Maintenance Supervisor, Campus Manager, and Deputy Medical Director. Parking outside the campus boundary is not in the VA s jurisdiction The contractor shall coordinate with the facility prior to work that impacts patient care such as shutting down A/C, heating, power or other utilities. Utility and HVAC shutdowns require at least a 14-day written request to the facility per the VA s internal Standard Operating Procedure. Period of performance is 90 calendar days.</p>","origin":"detail"},"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["561210"],"award":{"awardee":{}},"attachments":[{"resource_id":"9146485d322f44ada32f9c7f9a88ec6d","name":"36C24527Q0061.docx","kind":"file","mime_type":".docx","size_bytes":98648,"posted_at":"2026-11-12T16:12:59.205Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9146485d322f44ada32f9c7f9a88ec6d/download","mirrored":false},{"resource_id":"4ae37bd85df143fdb00aaedafb9e50b1","name":"36C24527Q0061_1.docx","kind":"file","mime_type":".docx","size_bytes":19921,"posted_at":"2026-11-12T15:19:12.551Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4ae37bd85df143fdb00aaedafb9e50b1/download","mirrored":false},{"resource_id":"f46ae901e58742ca9d19e72821d54e94","name":"Loch Raven VA Medical Center","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-11-12T15:19:12.551Z","export_controlled":false,"sha256":null,"url":"https://www.maryland.va.gov/locations/Loch_Raven_VA_Medical_","mirrored":false},{"resource_id":"c399dfc2196544b1a60e93d84e312bcb","name":"RFQ 36C24527Q0061 Questions.docx","kind":"file","mime_type":".docx","size_bytes":16656,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c399dfc2196544b1a60e93d84e312bcb/download","mirrored":false},{"resource_id":"002f79d71215497a98e044ebd647bc03","name":"MECHFLOW.pdf","kind":"file","mime_type":".pdf","size_bytes":149345,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/002f79d71215497a98e044ebd647bc03/download","mirrored":false},{"resource_id":"ddcd875cdfd04a2dbdfb014d5508a602","name":"Mecsked2.pdf","kind":"file","mime_type":".pdf","size_bytes":330780,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ddcd875cdfd04a2dbdfb014d5508a602/download","mirrored":false},{"resource_id":"b43ce3d7381e4abb8ef442c06e1329de","name":"1541 Loch Raven 2B TAB - CFR Review.pdf","kind":"file","mime_type":".pdf","size_bytes":649190,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b43ce3d7381e4abb8ef442c06e1329de/download","mirrored":false},{"resource_id":"e20ac73f9d6543cc8379ae875e36f56e","name":"2B Covid Ward Mechancial As-Builts pt 2.pdf","kind":"file","mime_type":".pdf","size_bytes":1206855,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e20ac73f9d6543cc8379ae875e36f56e/download","mirrored":false},{"resource_id":"e20fb65b90744a36a464431538f6c5ed","name":"20-M5.pdf","kind":"file","mime_type":".pdf","size_bytes":4366257,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e20fb65b90744a36a464431538f6c5ed/download","mirrored":false},{"resource_id":"93e346b7072441e98e46bc15f70f7bf4","name":"2B Covid Ward Mechancial As-Builts pt 1.pdf","kind":"file","mime_type":".pdf","size_bytes":3338512,"posted_at":"2026-11-18T21:40:47.942Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/93e346b7072441e98e46bc15f70f7bf4/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0052","latest_notice_id":"237d344cb6ac4b02b9937af00c11d9f5","title":"6830--Beckley VAMC Bulk Oxygen","solicitation_number":"36C24527Q0052","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325120","psc":"6830","set_aside":"SBA","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Beckley VA Medical Center","site_key":"beckley-va-medical-center-wv","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"75H70727Q00003","latest_notice_id":"7390db3f3afa46d3a8424450ec68c329","title":"Fire Door Inspection, Assessment, and Maintenance at the Albuquerque Area IHS Healthcare Facilities","solicitation_number":"75H70727Q00003","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-11-13","notices":5,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H707","office_name":"ALBUQUERQUE AREA INDIAN HEALTH SVC","naics":"561210","psc":"J012","set_aside":"SBA","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3502000","city_name":"Albuquerque","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-21T06:18:57.723715Z"},{"key":"FA462026QA303","latest_notice_id":"da68e1a3e39e41e0ae6b6adac38e3984","title":"FA27 Fall Arrest Inspection Services","solicitation_number":"FA462026QA303","notice_type":"r","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4620","office_name":"FA4620 92 CONS LGC","naics":"561210","psc":"H342","set_aside":"SBA","state":"WA","county":"53063","county_name":"Spokane County","city":"5322955","city_name":"Fairchild AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"M0068127R0002","latest_notice_id":"309bf2fd5f174025a6c27c4c74c1461a","title":"Parachute Rigger Sources Sought","solicitation_number":"M0068127R0002","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T08:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T08:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-M00681","office_name":"COMMANDING GENERAL","naics":"561210","psc":"H281","set_aside":null,"state":"AZ","county":"04027","county_name":"Yuma County","city":"0485680","city_name":"Yuma Proving Ground","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":37,"indexable":true}