{"canonical":"https://sealedbidder.com/opportunities/36c24526q0698","key":"36C24526Q0698","url":"https://sealedbidder.com/opportunities/36c24526q0698","title":"6515--688_Respiratory Airway & Monitoring Equipment (VA-26-00073765)","solicitation_number":"36C24526Q0698","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-14T17:00:00Z","first_posted":"2026-08-07","last_posted":"2026-08-07","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"809dcf6b2c974b9eaf6b7434760f45ab","title":"6515--688_Respiratory Airway & Monitoring Equipment (VA-26-00073765)","solicitation_number":"36C24526Q0698","notice_type":"r","base_type":"r","posted":"2026-08-07","posted_at":"2026-08-07T18:14:55.530Z","due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","cancelled":false,"archived":true,"archive_date":"2026-09-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/809dcf6b2c974b9eaf6b7434760f45ab/view","enriched":true,"history":[{"index":3,"title":"6515--688_Respiratory Airway & Monitoring Equipment (VA-26-00073765)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-07T18:14:55.530Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"809dcf6b2c974b9eaf6b7434760f45ab","solicitation_number":"36C24526Q0698"}]}],"latest_notice_id":"809dcf6b2c974b9eaf6b7434760f45ab","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-07","posted_at":"2026-08-07T18:14:55.530Z","created_at":"2026-08-07T18:14:53.351Z","modified_at":"2026-09-13T05:07:31.895Z","response_deadline":{"raw":"2026-08-14T13:00:00-04:00","utc":"2026-08-14T17:00:00Z","date":"2026-08-14","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/809dcf6b2c974b9eaf6b7434760f45ab/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--688_Respiratory Airway & Monitoring Equipment (VA-26-00073765)","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--688_Respiratory Airway & Monitoring Equipment (VA-26-00073765)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-07T18:14:55.530Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"809dcf6b2c974b9eaf6b7434760f45ab","solicitation_number":"36C24526Q0698"}],"contacts":[{"fax":"Charles.Cameron3@va.gov","name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"Charles Cameron","title":"Contract Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"809dcf6b2c974b9eaf6b7434760f45ab","lineage_id":"809dcf6b2c974b9eaf6b7434760f45ab","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T03:15:07.021882653Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"ba5a4fd53186030bf1e542fd346f794dbc78818dc07c9f505232ed60a9b508ee","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-25T03:15:07.021882653Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. \n\n\nScope of Work. The procurement shall include all parts, materials, installation labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nPA S00065 - IPV1, Airway Clearance, Dual Gas- Unit and Oxi Hose Only. NO Roll Stand (PA A50075-B), Pole Clamp (PA A50289) - Previously P/N PA K00065-US-NRS\n2\nPA A50075-B - Stand for IPV (A50075-B)\n2\nPA A50289 - IPV Stand Bracket System / Pole Clamp\n2\n104255 - tCOM+ Hospital USA\n1\n101342 - V-Sign Sensor VS-A/P/N [1/PK]\n1\nGCX-RS - Roll Stand GCX RS-0006-64 [1/PK] **Must order with plate**\n1\ntCOM-GCX-MP - tCOM+ Vesa Mounting Plate GCX FLP-0001-17 [1/PK]\n1\n\n\n4.2 Required Features\nIPV1 Airway Clearance (Brand Name or Equal):\n Unit dimensions must not be greater than 10  x 8  x 7 \nUnits must come with a cart or IV pole and be mountable to this cart or IV pole\nUnit weight no greater than 4 pounds\nOperating temperature range between 65 Â°F to 80 Â°F\nMust support wall gas source of 47-80 psi, 3.24-5.5 bar and flow > 35 lpm\nMust include automatic pulse interval ratio\nMust be capable of non-continuous run time\nMust support aerosol flow of 25 lpm (0.75 - 1 ml per minute liquid consumption rate)\nPulse amplitude of 0 to 50 cmH2O/hPa at 100 cycles per minute using SiemensÂ®-style 1L test lung or equivalent\nMust support a pulse amplitude of 100-300 pulses per minute\nMean airway pressure range must be 0-50 cmH2O\nBatteries:\nBatteries must be CR123A batteries\nBatteries must operate for at least 3,250 hours at 95 Â°F\n\ntCOM+ Respiratory Patient Monitor (Brand Name or Equal):\nMust measure tcPCO2 according to the following parameters:\nMeasurement range of 0-200 mmHg\nResolution of 0.1 mmHg (0.01 kPa) below 100 mmHg (10 kPa) / 1 mmHg (0.1 kPa) above 100 mmHg (10 kPa) \nDrift of < 0.5%/hour\nResponse time (T90) < 75 seconds\nLinearity < 1 mmHg\nMust measure tcPO2 according to the following parameters:\nMeasurement range of 0-800 mmHg\nResolution of 1 mmHg \nDrift of < 0.1%/hour\nResponse time (T90) < 150 seconds\nLinearity < 1 mmHg\nMust measure SpO2 according to the following parameters:\nApproved for earlobe, low on forehead, cheek, upper arm, scapula sites\nMeasurement range of 1-100%\nResolution of 1%\nMust measure PR according to the following parameters:\nMeasurement range of 30   250 bpm\nResolution of 1 bpm\nAccuracy Â± 3 bpm\nUnit dimensions must not be greater than 6  x 11  x 7 \nUnits must come with a cart and be mountable to this cart\nUnit weight no greater than 5.5 lbs, including gas cylinder\nMust be at least IPx2 certified and protected\nMust include foldable handle to carry the monitor\nMust run on 12 VDC power, max 0.3 A\nOperating temperature range between 41 Â°F to 104 Â°F\nAccuracy must be Â± 3 mmHg (0.4 kPa)\nBatteries:\nBatteries must be internal, rechargeable, sealed Li Ion Batteries\nFully charged battery must run for up to 4 hours\nCharging time must be no greater than 4 hours\n\n\n\n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work. \nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed on site and by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users and biomedical technicians. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n\nRESPONSES:Â \nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â \nPlease provide any product solution or configuration so long as they are equivalent to the brand name product. \nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â \nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: \nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ \nIf distributor, provide full name, business size, and address of manufacturer.Â \nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent. \nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â \nAuthorized Distributor Letter Certified by OEM with a current date.Â \nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â \n\n\nDISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.","text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nScope of Work. The procurement shall include all parts, materials, installation labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nPA S00065 - IPV1, Airway Clearance, Dual Gas- Unit and Oxi Hose Only. NO Roll Stand (PA A50075-B), Pole Clamp (PA A50289) - Previously P/N PA K00065-US-NRS\n2\nPA A50075-B - Stand for IPV (A50075-B)\n2\nPA A50289 - IPV Stand Bracket System / Pole Clamp\n2\n104255 - tCOM+ Hospital USA\n1\n101342 - V-Sign Sensor VS-A/P/N [1/PK]\n1\nGCX-RS - Roll Stand GCX RS-0006-64 [1/PK] **Must order with plate**\n1\ntCOM-GCX-MP - tCOM+ Vesa Mounting Plate GCX FLP-0001-17 [1/PK]\n1\n\n4.2 Required Features\nIPV1 Airway Clearance (Brand Name or Equal):\nUnit dimensions must not be greater than 10 x 8 x 7\nUnits must come with a cart or IV pole and be mountable to this cart or IV pole\nUnit weight no greater than 4 pounds\nOperating temperature range between 65 Â°F to 80 Â°F\nMust support wall gas source of 47-80 psi, 3.24-5.5 bar and flow > 35 lpm\nMust include automatic pulse interval ratio\nMust be capable of non-continuous run time\nMust support aerosol flow of 25 lpm (0.75 - 1 ml per minute liquid consumption rate)\nPulse amplitude of 0 to 50 cmH2O/hPa at 100 cycles per minute using SiemensÂ®-style 1L test lung or equivalent\nMust support a pulse amplitude of 100-300 pulses per minute\nMean airway pressure range must be 0-50 cmH2O\nBatteries:\nBatteries must be CR123A batteries\nBatteries must operate for at least 3,250 hours at 95 Â°F\n\ntCOM+ Respiratory Patient Monitor (Brand Name or Equal):\nMust measure tcPCO2 according to the following parameters:\nMeasurement range of 0-200 mmHg\nResolution of 0.1 mmHg (0.01 kPa) below 100 mmHg (10 kPa) / 1 mmHg (0.1 kPa) above 100 mmHg (10 kPa)\nDrift of < 0.5%/hour\nResponse time (T90) < 75 seconds\nLinearity < 1 mmHg\nMust measure tcPO2 according to the following parameters:\nMeasurement range of 0-800 mmHg\nResolution of 1 mmHg\nDrift of < 0.1%/hour\nResponse time (T90) < 150 seconds\nLinearity < 1 mmHg\nMust measure SpO2 according to the following parameters:\nApproved for earlobe, low on forehead, cheek, upper arm, scapula sites\nMeasurement range of 1-100%\nResolution of 1%\nMust measure PR according to the following parameters:\nMeasurement range of 30 250 bpm\nResolution of 1 bpm\nAccuracy Â± 3 bpm\nUnit dimensions must not be greater than 6 x 11 x 7\nUnits must come with a cart and be mountable to this cart\nUnit weight no greater than 5.5 lbs, including gas cylinder\nMust be at least IPx2 certified and protected\nMust include foldable handle to carry the monitor\nMust run on 12 VDC power, max 0.3 A\nOperating temperature range between 41 Â°F to 104 Â°F\nAccuracy must be Â± 3 mmHg (0.4 kPa)\nBatteries:\nBatteries must be internal, rechargeable, sealed Li Ion Batteries\nFully charged battery must run for up to 4 hours\nCharging time must be no greater than 4 hours\n\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed on site and by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users and biomedical technicians.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\nRESPONSES:Â\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ\nIf distributor, provide full name, business size, and address of manufacturer.Â\nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent.\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â\nAuthorized Distributor Letter Certified by OEM with a current date.Â\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â\n\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0698","place_of_performance":{"zip":"20422","city":{"name":"50 Irving St NW"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VAMC","street2":"50 Irving St NW"},"product_service_code":"6515"}],"due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","closes_at":"2026-08-14T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-25T03:40:37.123716Z","principal_notice_id":"809dcf6b2c974b9eaf6b7434760f45ab","description":{"text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nScope of Work. The procurement shall include all parts, materials, installation labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nPA S00065 - IPV1, Airway Clearance, Dual Gas- Unit and Oxi Hose Only. NO Roll Stand (PA A50075-B), Pole Clamp (PA A50289) - Previously P/N PA K00065-US-NRS\n2\nPA A50075-B - Stand for IPV (A50075-B)\n2\nPA A50289 - IPV Stand Bracket System / Pole Clamp\n2\n104255 - tCOM+ Hospital USA\n1\n101342 - V-Sign Sensor VS-A/P/N [1/PK]\n1\nGCX-RS - Roll Stand GCX RS-0006-64 [1/PK] **Must order with plate**\n1\ntCOM-GCX-MP - tCOM+ Vesa Mounting Plate GCX FLP-0001-17 [1/PK]\n1\n\n4.2 Required Features\nIPV1 Airway Clearance (Brand Name or Equal):\nUnit dimensions must not be greater than 10 x 8 x 7\nUnits must come with a cart or IV pole and be mountable to this cart or IV pole\nUnit weight no greater than 4 pounds\nOperating temperature range between 65 Â°F to 80 Â°F\nMust support wall gas source of 47-80 psi, 3.24-5.5 bar and flow > 35 lpm\nMust include automatic pulse interval ratio\nMust be capable of non-continuous run time\nMust support aerosol flow of 25 lpm (0.75 - 1 ml per minute liquid consumption rate)\nPulse amplitude of 0 to 50 cmH2O/hPa at 100 cycles per minute using SiemensÂ®-style 1L test lung or equivalent\nMust support a pulse amplitude of 100-300 pulses per minute\nMean airway pressure range must be 0-50 cmH2O\nBatteries:\nBatteries must be CR123A batteries\nBatteries must operate for at least 3,250 hours at 95 Â°F\n\ntCOM+ Respiratory Patient Monitor (Brand Name or Equal):\nMust measure tcPCO2 according to the following parameters:\nMeasurement range of 0-200 mmHg\nResolution of 0.1 mmHg (0.01 kPa) below 100 mmHg (10 kPa) / 1 mmHg (0.1 kPa) above 100 mmHg (10 kPa)\nDrift of < 0.5%/hour\nResponse time (T90) < 75 seconds\nLinearity < 1 mmHg\nMust measure tcPO2 according to the following parameters:\nMeasurement range of 0-800 mmHg\nResolution of 1 mmHg\nDrift of < 0.1%/hour\nResponse time (T90) < 150 seconds\nLinearity < 1 mmHg\nMust measure SpO2 according to the following parameters:\nApproved for earlobe, low on forehead, cheek, upper arm, scapula sites\nMeasurement range of 1-100%\nResolution of 1%\nMust measure PR according to the following parameters:\nMeasurement range of 30 250 bpm\nResolution of 1 bpm\nAccuracy Â± 3 bpm\nUnit dimensions must not be greater than 6 x 11 x 7\nUnits must come with a cart and be mountable to this cart\nUnit weight no greater than 5.5 lbs, including gas cylinder\nMust be at least IPx2 certified and protected\nMust include foldable handle to carry the monitor\nMust run on 12 VDC power, max 0.3 A\nOperating temperature range between 41 Â°F to 104 Â°F\nAccuracy must be Â± 3 mmHg (0.4 kPa)\nBatteries:\nBatteries must be internal, rechargeable, sealed Li Ion Batteries\nFully charged battery must run for up to 4 hours\nCharging time must be no greater than 4 hours\n\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed on site and by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users and biomedical technicians.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\nRESPONSES:Â\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ\nIf distributor, provide full name, business size, and address of manufacturer.Â\nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent.\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â\nAuthorized Distributor Letter Certified by OEM with a current date.Â\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â\n\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. \n\n\nScope of Work. The procurement shall include all parts, materials, installation labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nPA S00065 - IPV1, Airway Clearance, Dual Gas- Unit and Oxi Hose Only. NO Roll Stand (PA A50075-B), Pole Clamp (PA A50289) - Previously P/N PA K00065-US-NRS\n2\nPA A50075-B - Stand for IPV (A50075-B)\n2\nPA A50289 - IPV Stand Bracket System / Pole Clamp\n2\n104255 - tCOM+ Hospital USA\n1\n101342 - V-Sign Sensor VS-A/P/N [1/PK]\n1\nGCX-RS - Roll Stand GCX RS-0006-64 [1/PK] **Must order with plate**\n1\ntCOM-GCX-MP - tCOM+ Vesa Mounting Plate GCX FLP-0001-17 [1/PK]\n1\n\n\n4.2 Required Features\nIPV1 Airway Clearance (Brand Name or Equal):\n Unit dimensions must not be greater than 10  x 8  x 7 \nUnits must come with a cart or IV pole and be mountable to this cart or IV pole\nUnit weight no greater than 4 pounds\nOperating temperature range between 65 Â°F to 80 Â°F\nMust support wall gas source of 47-80 psi, 3.24-5.5 bar and flow > 35 lpm\nMust include automatic pulse interval ratio\nMust be capable of non-continuous run time\nMust support aerosol flow of 25 lpm (0.75 - 1 ml per minute liquid consumption rate)\nPulse amplitude of 0 to 50 cmH2O/hPa at 100 cycles per minute using SiemensÂ®-style 1L test lung or equivalent\nMust support a pulse amplitude of 100-300 pulses per minute\nMean airway pressure range must be 0-50 cmH2O\nBatteries:\nBatteries must be CR123A batteries\nBatteries must operate for at least 3,250 hours at 95 Â°F\n\ntCOM+ Respiratory Patient Monitor (Brand Name or Equal):\nMust measure tcPCO2 according to the following parameters:\nMeasurement range of 0-200 mmHg\nResolution of 0.1 mmHg (0.01 kPa) below 100 mmHg (10 kPa) / 1 mmHg (0.1 kPa) above 100 mmHg (10 kPa) \nDrift of < 0.5%/hour\nResponse time (T90) < 75 seconds\nLinearity < 1 mmHg\nMust measure tcPO2 according to the following parameters:\nMeasurement range of 0-800 mmHg\nResolution of 1 mmHg \nDrift of < 0.1%/hour\nResponse time (T90) < 150 seconds\nLinearity < 1 mmHg\nMust measure SpO2 according to the following parameters:\nApproved for earlobe, low on forehead, cheek, upper arm, scapula sites\nMeasurement range of 1-100%\nResolution of 1%\nMust measure PR according to the following parameters:\nMeasurement range of 30   250 bpm\nResolution of 1 bpm\nAccuracy Â± 3 bpm\nUnit dimensions must not be greater than 6  x 11  x 7 \nUnits must come with a cart and be mountable to this cart\nUnit weight no greater than 5.5 lbs, including gas cylinder\nMust be at least IPx2 certified and protected\nMust include foldable handle to carry the monitor\nMust run on 12 VDC power, max 0.3 A\nOperating temperature range between 41 Â°F to 104 Â°F\nAccuracy must be Â± 3 mmHg (0.4 kPa)\nBatteries:\nBatteries must be internal, rechargeable, sealed Li Ion Batteries\nFully charged battery must run for up to 4 hours\nCharging time must be no greater than 4 hours\n\n\n\n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work. \nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed on site and by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users and biomedical technicians. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n\nRESPONSES:Â \nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â \nPlease provide any product solution or configuration so long as they are equivalent to the brand name product. \nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â \nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: \nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ \nIf distributor, provide full name, business size, and address of manufacturer.Â \nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent. \nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â \nAuthorized Distributor Letter Certified by OEM with a current date.Â \nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â \n\n\nDISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"contacts":[{"fax":"Charles.Cameron3@va.gov","name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"Charles Cameron","title":"Contract Officer"}],"place_of_performance":{"zip":"20422","city":{"name":"50 Irving St NW"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VAMC","street2":"50 Irving St NW"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"80ad9fae9e864f29947a36edf73cd16a","name":"36C24526Q0698.docx","kind":"file","mime_type":".docx","size_bytes":22121,"posted_at":"2026-08-07T18:14:55.530Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/80ad9fae9e864f29947a36edf73cd16a/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":16,"indexable":false}