Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,555 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

INSTRUMENT CALIBRATION SERVICE

36C24526Q0678

Department of Veterans Affairs, 245-Network Contract Office 5. Testing Laboratories and Services.

Response deadline

July 31, 2026 at 3:00 PM EDT

Closed 117 days ago. Posted July 20, 2026. Scheduled to archive September 29, 2026.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2026

34 like it are open now in testing laboratories and services

All 34 open in testing laboratories and services

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 541380 (testing laboratories and services), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation has been published under this number yet. The sources sought of July 20, 2026 is the earliest notice of the purchase.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Veterans Health Administration, Network Contracting Office 5 (NCO 5) is issuing this source sought notice (Only) pursuant to the Federal Acquisition Regulations (FAR) Part 10, Market Research. Contractor will provide all resources necessary to perform calibrations on these types of radiation survey instruments in accordance to the statement of work. Contractor will also provide instrument repair services as needed. Contractor will be responsible for return shipment of instruments back to MERRT members who are geographically dispersed throughout the U.S. The purpose of the sources sought is to gain knowledge of potential qualified sources and their size classifications relative to NAICS 541380. It will also be used to identify qualified and responsible small business vendors (e.g. Service Disabled/Veteran-Owned Small Business (SDVOSB/VOSB), Historically Underutilized Business Zone (HUBZone), 8(a), small disadvantaged, women-owned small business). Interested & Capable Respondents in this procurement and consider themselves to have the resources, capabilities and qualifications necessary to provide this service, please respond with your: Business name, address, business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, Women Owned Small Business, 8(a), Large Business, etc.), and person of contact (including telephone number & email address) and point of contact information. Provide your Unique Entity Identifier (UEI) number. Is your company considered small under the NAICS code identified under this source sought? Capability statement and summary of previous experience providing radiation survey instrument calibration and repair services for the Veterans Health Administration or other Federal agencies. Be sure to include information pertaining to your company s licensing by regulatory authorities, industry/ISO certifications obtained, and other pertinent information. Whether you hold GSA Federal Supply Schedule contract and contract number. General estimated pricing for your product/services. Pricing will be used for the purpose of market research only. Responses must be submitted by 3:00 PM (EDT) July 31, 2026. All information regarding Capabilities Statements or any other proprietary information relative to this sources sought shall be submitted via email to Charles.willis@va.gov. This request for sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice. All information received in response to this source sought that is marked Proprietary will be handled accordingly. statement of work MERRT Radiation Survey Instrument Calibration and Repair Purpose. VHA Office of Emergency Management (OEM), will contract for radiation safety instrument calibration services required to support the VHA Medical Emergency Radiological Response Team (MERRT). Background. The MERRT, as established by VHA Directive 0320.05, is a specialized team of healthcare professionals with radiological expertise that can be rapidly deployed to a VHA or off-site medical provider to render patient treatment and technical advice during a radiological emergency. Objectives. The contract, once established, will provide a mechanism for MERRT members, who are geographically dispersed throughout the United States, to have MERRT radiation safety instruments calibrated annually. Four option years are required. Scope. The Contractor shall provide annual calibration of all MERRT radiation survey equipment. The Contractor will provide instrument repair service as needed and specified in the contract. Four option years are required. Contractor Requirements. The contractor shall be able to meet the following requirements: Factor #1: Ability to calibrate radiation detection instruments listed below, in-house. Factor #2: Ability to repair radiation detection instruments listed below. Factor #3: Must have alpha and beta emitting radiation sources for alpha/beta probe calibrations Factor #4: Must have a high energy gamma ray emitting source for standard instrument calibration. Factor #5: Must meet ANSI N323 compliance standard for portable radiological instruments. Factor #6: Ability to calibrate instruments within a 15 day turn-around time. Factors 1-5 are equally important; these are mandatory in order to be able to perform the services. Factor #6 is less important than the other factors but should not go over 30 days. Mandatory Tasks and Deliverables. The contractor shall provide annual calibration of all MERRT radiation survey equipment. Shipping costs for instrument return to the customer and shipment for repair are the responsibility of the contractor. The contractor will provide instrument repair service as needed and specified in the contract. If for any reason, any deliverable cannot be delivered on time according to the below schedule, the contractor shall provide a written explanation three days prior to the due date to the Contracting Officer Representative (COR). This written transmittal shall include a firm commitment of when the work shall be completed. This transmittal to the COR shall cite reasons for the delay, and the impact on the overall project. The COR will review collaboratively with the program office and facts and issue a response in accordance with the contract terms and conditions. Unless otherwise specified an electronic copy shall be placed in the designated CBO SharePoint site or other CBO-designated site. Specifically, the contractor shall: 6.1 Task One. The contractor shall calibrate, using NIST traceable sources and methods approved in ANSI N323 series of documents for radiation survey instruments, the following radiation survey equipment: Deliverable 6.1.1. Calibrate 20 ea. Ludlum Model 2241-3 or 3001-3 survey kit. Each kit requires calibration of meter and 3 included probes. Deliverable 6.1.2. Calibrate 10 ea. Ludlum Model 2224-1 survey kit. Each kit requires calibration of meter and 2 included probes. Deliverable 6.1.3. Calibrate 10 ea. Ludlum Model 2401P or other model Geiger-Mueller survey meter. Deliverable 6.1.4 Calibrate 4 ea. Ludlum Model 52-5-1 Portable Portal Monitor. Deliverable 6.1.5 Calibrate 30 ea Polimaster PM1703-1. 6.2 Task Two. Radiation survey equipment repair and COR responsibility/authority Deliverable 6.2.1. Contractor will inspect instruments when received for calibration. If repairs are required, or are requested by the COR, the contractor will contact the COR with an estimate of the repair cost and an estimated completion date. Contractor will repair instruments with COR authorization up to, but not in excess of, the Not to Exceed (NTE) amount of the contract. Expenditures authorized by the COR or incurred by the contractor in excess of the NTE amount will be disallowed unless approved in advance, in writing, in the form of an amendment to the contract raising the NTE, by the Contracting Officer. Additionally, the COR shall not obligate the government to any expenditures not specifically covered in the contract. 6.3 Schedule for Mandatory Deliverables. 6.3.1 Table of Base Period Mandatory Deliverables Due Dates REFERENCE DELIVERABLE DUE DATE 6.1.1 Calibrate 20 ea. Ludlum Model 2241-3 or 3001-3 survey kit. Within 15 days of receipt of equipment by contractor. 6.1.2 Calibrate 10 ea. Ludlum Model 2224-1 survey kit Within 15 days of receipt of equipment by contractor. 6.1.3 Calibrate 10 ea. Ludlum Model 2401P or other model Geiger-Mueller survey meter. Within 15 days of receipt of equipment by contractor. 6.1.4 Calibrate 4 ea. Ludlum Model 52-5-1 Portable Portal Monitor. Within 15 days of receipt of equipment by contractor. 6.1.5 Calibrate 30 ea Polimaster PM1703-1 Within 15 days of receipt of equipment by contractor. 6.2.1 Contractor will inspect and repair instruments when received for calibration. Within 30 days of receipt of equipment by contractor

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 20, 2026

    Sources sought

    Due July 31, 2026 at 3:00 PM EDT. SAM.gov, notice 36d7f093a7094949ae00e47baee89690

    1 revision on SAM
    • July 20, 2026: publish, sources sought

Points of contact