{"canonical":"https://sealedbidder.com/opportunities/36c24526q0674","key":"36C24526Q0674","url":"https://sealedbidder.com/opportunities/36c24526q0674","title":"6515--688_Microwave Ablation System (VA-26-00077651)","solicitation_number":"36C24526Q0674","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-30T17:00:00Z","first_posted":"2026-07-25","last_posted":"2026-07-25","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"c899430fc8d0471a82108eb40aba1e2d","title":"6515--688_Microwave Ablation System (VA-26-00077651)","solicitation_number":"36C24526Q0674","notice_type":"r","base_type":"r","posted":"2026-07-25","posted_at":"2026-07-25T22:15:11.043Z","due_at":"2026-07-30T17:00:00Z","due_date":"2026-07-30","cancelled":false,"archived":true,"archive_date":"2026-08-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c899430fc8d0471a82108eb40aba1e2d/view","enriched":true,"history":[{"index":3,"title":"6515--688_Microwave Ablation System (VA-26-00077651)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-25T22:15:11.043Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c899430fc8d0471a82108eb40aba1e2d","solicitation_number":"36C24526Q0674"}]}],"latest_notice_id":"c899430fc8d0471a82108eb40aba1e2d","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-25","posted_at":"2026-07-25T22:15:11.043Z","created_at":"2026-07-25T22:15:08.783Z","modified_at":"2026-08-29T05:07:01.482Z","response_deadline":{"raw":"2026-07-30T13:00:00-04:00","utc":"2026-07-30T17:00:00Z","date":"2026-07-30","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c899430fc8d0471a82108eb40aba1e2d/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--688_Microwave Ablation System (VA-26-00077651)","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--688_Microwave Ablation System (VA-26-00077651)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-25T22:15:11.043Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c899430fc8d0471a82108eb40aba1e2d","solicitation_number":"36C24526Q0674"}],"contacts":[{"name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"(304) 623-3461 x4143","title":"Contract Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"c899430fc8d0471a82108eb40aba1e2d","lineage_id":"c899430fc8d0471a82108eb40aba1e2d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-28T00:28:49.487516788Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"6debbded6cecb9adbca173b637f66ec713534bb8aa7320727c238e6ba562dd2e","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-28T00:28:49.487516788Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nBackground. The Washington DC VA Medical Center (DC VAMC) requires a new microwave ablation system to be used in the interventional radiology suites. The current ablation system is reaching end of service by 9/31/2026 and has passed its HTM life expectancy (5 years, purchased in 2018). This ablation system is used 2-3 times per week and is essential for providing oncology treatment for kidney, liver, and lung cases. This new system must be compatible with SyngoVia software used at the DC VAMC.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nIB-SYS-MAG-SVG-H - IntelliBlate Microwave Ablation System with MyAblation Guide deployed on Syngo.via View & Go, with external computer\n1\n\n\n4.2 Required Features\nTwo fully integrated peristaltic pumps\n15.6 inch foldable touchscreen\n180Â° CW/CCW swivels\nTouchscreen operable with gloved fingers and sterile drape\nOne USB port and one ethernet port\nIncludes tract ablation feature   cauterizes needle tract\nIncludes needle lock feature   probe migration solution\nCoolant capacity of 100 mL or greater, sterile water of 0.9% saline\nMWA generator frequency 2.45 GHz Â± 50 MHz\nApplied part type BF   independent channel controls\nApplied part type BF   two remote temperature probe support\nOutput power single channel   0-90 W\nOutput power two channel   0-80 W each\nMicrowave output power accuracy\nWithin 10 seconds of activation of output energy on the touchscreen: \nPower (tip referenced) <25 W: Â± 20%\nPower (tip references)   25 W: Â± 5 W or Â± 8%\nXimitry Probe Antenna Temperature Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nTemperature Probe Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nWeight with cart   95 lbs\nDimensions with cart\nW   24 in\nD   22 in\nH   43.4 in (touchscreen closed)\nH   52.75 in (touchscreen open)\nElectrical power connection 100 VAC-240 VAC, 50 Hz/60Hz, 900 VA\nPower cord length   25 ft\n\nSpecific Tasks.  \n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n5.5 Inspection and Acceptance. \nContractor shall conduct a joint inspection with the on-site POC upon completion of installation. \nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.  \n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays: \nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nRESPONSES:Â \nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â \nPlease provide any product solution or configuration so long as they are equivalent to the brand name product. \nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â \nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: \nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ \nIf distributor, provide full name, business size, and address of manufacturer.Â \nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent. \nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â \nAuthorized Distributor Letter Certified by OEM with a current date.Â \nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â","text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nBackground. The Washington DC VA Medical Center (DC VAMC) requires a new microwave ablation system to be used in the interventional radiology suites. The current ablation system is reaching end of service by 9/31/2026 and has passed its HTM life expectancy (5 years, purchased in 2018). This ablation system is used 2-3 times per week and is essential for providing oncology treatment for kidney, liver, and lung cases. This new system must be compatible with SyngoVia software used at the DC VAMC.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nIB-SYS-MAG-SVG-H - IntelliBlate Microwave Ablation System with MyAblation Guide deployed on Syngo.via View & Go, with external computer\n1\n\n4.2 Required Features\nTwo fully integrated peristaltic pumps\n15.6 inch foldable touchscreen\n180Â° CW/CCW swivels\nTouchscreen operable with gloved fingers and sterile drape\nOne USB port and one ethernet port\nIncludes tract ablation feature cauterizes needle tract\nIncludes needle lock feature probe migration solution\nCoolant capacity of 100 mL or greater, sterile water of 0.9% saline\nMWA generator frequency 2.45 GHz Â± 50 MHz\nApplied part type BF independent channel controls\nApplied part type BF two remote temperature probe support\nOutput power single channel 0-90 W\nOutput power two channel 0-80 W each\nMicrowave output power accuracy\nWithin 10 seconds of activation of output energy on the touchscreen:\nPower (tip referenced) <25 W: Â± 20%\nPower (tip references) 25 W: Â± 5 W or Â± 8%\nXimitry Probe Antenna Temperature Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nTemperature Probe Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nWeight with cart 95 lbs\nDimensions with cart\nW 24 in\nD 22 in\nH 43.4 in (touchscreen closed)\nH 52.75 in (touchscreen open)\nElectrical power connection 100 VAC-240 VAC, 50 Hz/60Hz, 900 VA\nPower cord length 25 ft\n\nSpecific Tasks.\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\n5.5 Inspection and Acceptance.\nContractor shall conduct a joint inspection with the on-site POC upon completion of installation.\nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.\n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays:\nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nRESPONSES:Â\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ\nIf distributor, provide full name, business size, and address of manufacturer.Â\nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent.\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â\nAuthorized Distributor Letter Certified by OEM with a current date.Â\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0674","place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VAMC","street2":"50 Irving St NW"},"product_service_code":"6515"}],"due_at":"2026-07-30T17:00:00Z","due_date":"2026-07-30","closes_at":"2026-07-30T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-28T01:19:32.116417Z","principal_notice_id":"c899430fc8d0471a82108eb40aba1e2d","description":{"text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nBackground. The Washington DC VA Medical Center (DC VAMC) requires a new microwave ablation system to be used in the interventional radiology suites. The current ablation system is reaching end of service by 9/31/2026 and has passed its HTM life expectancy (5 years, purchased in 2018). This ablation system is used 2-3 times per week and is essential for providing oncology treatment for kidney, liver, and lung cases. This new system must be compatible with SyngoVia software used at the DC VAMC.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nIB-SYS-MAG-SVG-H - IntelliBlate Microwave Ablation System with MyAblation Guide deployed on Syngo.via View & Go, with external computer\n1\n\n4.2 Required Features\nTwo fully integrated peristaltic pumps\n15.6 inch foldable touchscreen\n180Â° CW/CCW swivels\nTouchscreen operable with gloved fingers and sterile drape\nOne USB port and one ethernet port\nIncludes tract ablation feature cauterizes needle tract\nIncludes needle lock feature probe migration solution\nCoolant capacity of 100 mL or greater, sterile water of 0.9% saline\nMWA generator frequency 2.45 GHz Â± 50 MHz\nApplied part type BF independent channel controls\nApplied part type BF two remote temperature probe support\nOutput power single channel 0-90 W\nOutput power two channel 0-80 W each\nMicrowave output power accuracy\nWithin 10 seconds of activation of output energy on the touchscreen:\nPower (tip referenced) <25 W: Â± 20%\nPower (tip references) 25 W: Â± 5 W or Â± 8%\nXimitry Probe Antenna Temperature Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nTemperature Probe Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nWeight with cart 95 lbs\nDimensions with cart\nW 24 in\nD 22 in\nH 43.4 in (touchscreen closed)\nH 52.75 in (touchscreen open)\nElectrical power connection 100 VAC-240 VAC, 50 Hz/60Hz, 900 VA\nPower cord length 25 ft\n\nSpecific Tasks.\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\n5.5 Inspection and Acceptance.\nContractor shall conduct a joint inspection with the on-site POC upon completion of installation.\nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.\n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays:\nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nRESPONSES:Â\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ\nIf distributor, provide full name, business size, and address of manufacturer.Â\nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent.\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â\nAuthorized Distributor Letter Certified by OEM with a current date.Â\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â","html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nBackground. The Washington DC VA Medical Center (DC VAMC) requires a new microwave ablation system to be used in the interventional radiology suites. The current ablation system is reaching end of service by 9/31/2026 and has passed its HTM life expectancy (5 years, purchased in 2018). This ablation system is used 2-3 times per week and is essential for providing oncology treatment for kidney, liver, and lung cases. This new system must be compatible with SyngoVia software used at the DC VAMC.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nIB-SYS-MAG-SVG-H - IntelliBlate Microwave Ablation System with MyAblation Guide deployed on Syngo.via View & Go, with external computer\n1\n\n\n4.2 Required Features\nTwo fully integrated peristaltic pumps\n15.6 inch foldable touchscreen\n180Â° CW/CCW swivels\nTouchscreen operable with gloved fingers and sterile drape\nOne USB port and one ethernet port\nIncludes tract ablation feature   cauterizes needle tract\nIncludes needle lock feature   probe migration solution\nCoolant capacity of 100 mL or greater, sterile water of 0.9% saline\nMWA generator frequency 2.45 GHz Â± 50 MHz\nApplied part type BF   independent channel controls\nApplied part type BF   two remote temperature probe support\nOutput power single channel   0-90 W\nOutput power two channel   0-80 W each\nMicrowave output power accuracy\nWithin 10 seconds of activation of output energy on the touchscreen: \nPower (tip referenced) <25 W: Â± 20%\nPower (tip references)   25 W: Â± 5 W or Â± 8%\nXimitry Probe Antenna Temperature Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nTemperature Probe Measurement\n10-60Â°C (Â±3Â°C accuracy)\n60-85Â°C (Â±6Â°C accuracy)\n85-100Â°C (Â±10Â°C accuracy)\nWeight with cart   95 lbs\nDimensions with cart\nW   24 in\nD   22 in\nH   43.4 in (touchscreen closed)\nH   52.75 in (touchscreen open)\nElectrical power connection 100 VAC-240 VAC, 50 Hz/60Hz, 900 VA\nPower cord length   25 ft\n\nSpecific Tasks.  \n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n5.5 Inspection and Acceptance. \nContractor shall conduct a joint inspection with the on-site POC upon completion of installation. \nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.  \n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays: \nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nRESPONSES:Â \nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â \nPlease provide any product solution or configuration so long as they are equivalent to the brand name product. \nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â \nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: \nFull name and address of company\nDUNS number/ CAGE Code/ SAM UEI\nBusiness Size\nManufacturer or DistributorÂ \nIf distributor, provide full name, business size, and address of manufacturer.Â \nCountry of Origin designation for all products.\nTechnical Literature that clearly shows product(s) are equivalent. \nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â \nAuthorized Distributor Letter Certified by OEM with a current date.Â \nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â","origin":"detail"},"contacts":[{"name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"(304) 623-3461 x4143","title":"Contract Officer"}],"place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VAMC","street2":"50 Irving St NW"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"74f558ee97114e69a50b085f839857f3","name":"36C24526Q0674.docx","kind":"file","mime_type":".docx","size_bytes":22648,"posted_at":"2026-07-25T22:15:11.043Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/74f558ee97114e69a50b085f839857f3/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":16,"indexable":false}