{"canonical":"https://sealedbidder.com/opportunities/36c24526q0640","key":"36C24526Q0640","url":"https://sealedbidder.com/opportunities/36c24526q0640","title":"6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)","solicitation_number":"36C24526Q0640","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-14T17:00:00Z","first_posted":"2026-07-07","last_posted":"2026-07-07","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"67b00a03c27d47febebb7535ea1ee60b","title":"6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)","solicitation_number":"36C24526Q0640","notice_type":"r","base_type":"r","posted":"2026-07-07","posted_at":"2026-07-07T14:57:32.135Z","due_at":"2026-07-14T17:00:00Z","due_date":"2026-07-14","cancelled":false,"archived":true,"archive_date":"2026-08-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/67b00a03c27d47febebb7535ea1ee60b/view","enriched":true,"history":[{"index":3,"title":"6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-07T14:57:32.135Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"67b00a03c27d47febebb7535ea1ee60b","solicitation_number":"36C24526Q0640"}]}],"latest_notice_id":"67b00a03c27d47febebb7535ea1ee60b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-07","posted_at":"2026-07-07T14:57:32.135Z","created_at":"2026-07-07T14:57:29.927Z","modified_at":"2026-08-13T05:07:38.691Z","response_deadline":{"raw":"2026-07-14T13:00:00-04:00","utc":"2026-07-14T17:00:00Z","date":"2026-07-14","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/67b00a03c27d47febebb7535ea1ee60b/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-07T14:57:32.135Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"67b00a03c27d47febebb7535ea1ee60b","solicitation_number":"36C24526Q0640"}],"contacts":[{"name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"(304) 623-3461 x4143","title":"Contract Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"67b00a03c27d47febebb7535ea1ee60b","lineage_id":"67b00a03c27d47febebb7535ea1ee60b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T04:08:24.016863601Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"39973e097ffe376833a5c99a36af31fb0e0c016927da8ef674069dfa30b9673d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T04:08:24.016863601Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. \n\n \n\nSCOPE OF WORK -Vendor will provide all equipment necessary to meet the Statement of Work  below. \n\nSTATEMENT OF WORK PART B   WORK REQUIREMENTS \n\nB.1  TO BE PROVIDED:  \nThe procurement is for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nSYS-01-00100   ForeSite SS Tablet + 2 LX100:36.36.02 (X4)\n1\nASY-01-00164   LX100:40.40.02-X4, Pressure Range: 5-200 mmHG (0.1   3.9 psi)\n1\n\n\n4.2 Required Features\n1 ForeSite SS Tablet (with charger)\n2 X4 Sensor Pack (with charger)\n1 USB Key to include:\nForeSite SS Desktop Software\nUser Guide\n2 Mico-USB to USB Cable (to allow for a wired connection)\n1 Dual USB Hub\n1 Carry Case\n1 LX100:40.40.02 Sensor\nSensing Area: 50.8 cm x 50.8 cm (20  x 20 )\nResolution: 12.7 mm (0.5 )\nSensing Points: 1,600\nPressure Range: 5-200 mmHg\n1 LX100.36.36.02 Sensor\nSensing Area: 45 cm x 45 cm (18  x 18 )\nResolution: 12.7 mm (0.5 )\nPressure Range: 5-200 mmHg\n\nThis system is a CSA/CE Class 1 ISO 60601-1 medically approved product. The ForeSite SS Tablet comes with preinstalled ForeSite SS software and is intended as a secure, easy-to-use, pressure mapping specific device. This system is intended for clinicians in a hospital setting who require secure devices with user password protection, encrypted patient files, and the ability to pressure map without cables connecting the Tablet to the sensor. The sensors come connected to the X4 Sensor Packs and have the option to transmit data to the ForeSite SS Tablet via Bluetooth (alternatively, you have the choice to use the system via a wired USB connection). High resolution sensors are critical to seeing surfaces pressures and making informed recommendations.\n\nSTATEMENT OF WORK PART C   SUPPORTING INFORMATION \n\nC.1 Place of Performance   Washington DC VA Medical Center located at 50 Irving St NW, Washington, DC 20422. Delivery vehicles shall keep traffic disruptions to a minimum.  Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times. \n\nC.2 Period of Performance   Vendor will provide equipment within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM   430PM The Contractor shall perform all services during normal business hours.  \n\nRESPONSES:  \n\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.  \n\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.  \n\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.  \n\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:  \n\nFull name and address of company \n\nDUNS number/ CAGE Code/ SAM UEI \n\nBusiness Size \n\nManufacturer or Distributor  \n\nIf distributor, provide full name, business size, and address of manufacturer.  \n\nCountry of Origin designation for all products. \n\nTechnical Literature that clearly shows product(s) are equivalent.  \n\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified.   \n\nAuthorized Distributor Letter Certified by OEM with a current date.  \n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. \nDISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.","text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nSCOPE OF WORK -Vendor will provide all equipment necessary to meet the Statement of Work below.\n\nSTATEMENT OF WORK PART B WORK REQUIREMENTS\n\nB.1 TO BE PROVIDED:\nThe procurement is for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nSYS-01-00100 ForeSite SS Tablet + 2 LX100:36.36.02 (X4)\n1\nASY-01-00164 LX100:40.40.02-X4, Pressure Range: 5-200 mmHG (0.1 3.9 psi)\n1\n\n4.2 Required Features\n1 ForeSite SS Tablet (with charger)\n2 X4 Sensor Pack (with charger)\n1 USB Key to include:\nForeSite SS Desktop Software\nUser Guide\n2 Mico-USB to USB Cable (to allow for a wired connection)\n1 Dual USB Hub\n1 Carry Case\n1 LX100:40.40.02 Sensor\nSensing Area: 50.8 cm x 50.8 cm (20 x 20 )\nResolution: 12.7 mm (0.5 )\nSensing Points: 1,600\nPressure Range: 5-200 mmHg\n1 LX100.36.36.02 Sensor\nSensing Area: 45 cm x 45 cm (18 x 18 )\nResolution: 12.7 mm (0.5 )\nPressure Range: 5-200 mmHg\n\nThis system is a CSA/CE Class 1 ISO 60601-1 medically approved product. The ForeSite SS Tablet comes with preinstalled ForeSite SS software and is intended as a secure, easy-to-use, pressure mapping specific device. This system is intended for clinicians in a hospital setting who require secure devices with user password protection, encrypted patient files, and the ability to pressure map without cables connecting the Tablet to the sensor. The sensors come connected to the X4 Sensor Packs and have the option to transmit data to the ForeSite SS Tablet via Bluetooth (alternatively, you have the choice to use the system via a wired USB connection). High resolution sensors are critical to seeing surfaces pressures and making informed recommendations.\n\nSTATEMENT OF WORK PART C SUPPORTING INFORMATION\n\nC.1 Place of Performance Washington DC VA Medical Center located at 50 Irving St NW, Washington, DC 20422. Delivery vehicles shall keep traffic disruptions to a minimum. Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.\n\nC.2 Period of Performance Vendor will provide equipment within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM 430PM The Contractor shall perform all services during normal business hours.\n\nRESPONSES:\n\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.\n\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\n\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UEI\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf distributor, provide full name, business size, and address of manufacturer.\n\nCountry of Origin designation for all products.\n\nTechnical Literature that clearly shows product(s) are equivalent.\n\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0640","place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs VAMC","street2":"50 Irving St NW"},"product_service_code":"6515"}],"due_at":"2026-07-14T17:00:00Z","due_date":"2026-07-14","closes_at":"2026-07-14T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T04:14:25.251125Z","principal_notice_id":"67b00a03c27d47febebb7535ea1ee60b","description":{"text":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nSCOPE OF WORK -Vendor will provide all equipment necessary to meet the Statement of Work below.\n\nSTATEMENT OF WORK PART B WORK REQUIREMENTS\n\nB.1 TO BE PROVIDED:\nThe procurement is for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nSYS-01-00100 ForeSite SS Tablet + 2 LX100:36.36.02 (X4)\n1\nASY-01-00164 LX100:40.40.02-X4, Pressure Range: 5-200 mmHG (0.1 3.9 psi)\n1\n\n4.2 Required Features\n1 ForeSite SS Tablet (with charger)\n2 X4 Sensor Pack (with charger)\n1 USB Key to include:\nForeSite SS Desktop Software\nUser Guide\n2 Mico-USB to USB Cable (to allow for a wired connection)\n1 Dual USB Hub\n1 Carry Case\n1 LX100:40.40.02 Sensor\nSensing Area: 50.8 cm x 50.8 cm (20 x 20 )\nResolution: 12.7 mm (0.5 )\nSensing Points: 1,600\nPressure Range: 5-200 mmHg\n1 LX100.36.36.02 Sensor\nSensing Area: 45 cm x 45 cm (18 x 18 )\nResolution: 12.7 mm (0.5 )\nPressure Range: 5-200 mmHg\n\nThis system is a CSA/CE Class 1 ISO 60601-1 medically approved product. The ForeSite SS Tablet comes with preinstalled ForeSite SS software and is intended as a secure, easy-to-use, pressure mapping specific device. This system is intended for clinicians in a hospital setting who require secure devices with user password protection, encrypted patient files, and the ability to pressure map without cables connecting the Tablet to the sensor. The sensors come connected to the X4 Sensor Packs and have the option to transmit data to the ForeSite SS Tablet via Bluetooth (alternatively, you have the choice to use the system via a wired USB connection). High resolution sensors are critical to seeing surfaces pressures and making informed recommendations.\n\nSTATEMENT OF WORK PART C SUPPORTING INFORMATION\n\nC.1 Place of Performance Washington DC VA Medical Center located at 50 Irving St NW, Washington, DC 20422. Delivery vehicles shall keep traffic disruptions to a minimum. Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.\n\nC.2 Period of Performance Vendor will provide equipment within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM 430PM The Contractor shall perform all services during normal business hours.\n\nRESPONSES:\n\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.\n\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.\n\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UEI\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf distributor, provide full name, business size, and address of manufacturer.\n\nCountry of Origin designation for all products.\n\nTechnical Literature that clearly shows product(s) are equivalent.\n\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","html":"This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.  Any resulting procurement action will be the subject of a separate, future announcement.  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. \n\n \n\nSCOPE OF WORK -Vendor will provide all equipment necessary to meet the Statement of Work  below. \n\nSTATEMENT OF WORK PART B   WORK REQUIREMENTS \n\nB.1  TO BE PROVIDED:  \nThe procurement is for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description \nQuantity\nSYS-01-00100   ForeSite SS Tablet + 2 LX100:36.36.02 (X4)\n1\nASY-01-00164   LX100:40.40.02-X4, Pressure Range: 5-200 mmHG (0.1   3.9 psi)\n1\n\n\n4.2 Required Features\n1 ForeSite SS Tablet (with charger)\n2 X4 Sensor Pack (with charger)\n1 USB Key to include:\nForeSite SS Desktop Software\nUser Guide\n2 Mico-USB to USB Cable (to allow for a wired connection)\n1 Dual USB Hub\n1 Carry Case\n1 LX100:40.40.02 Sensor\nSensing Area: 50.8 cm x 50.8 cm (20  x 20 )\nResolution: 12.7 mm (0.5 )\nSensing Points: 1,600\nPressure Range: 5-200 mmHg\n1 LX100.36.36.02 Sensor\nSensing Area: 45 cm x 45 cm (18  x 18 )\nResolution: 12.7 mm (0.5 )\nPressure Range: 5-200 mmHg\n\nThis system is a CSA/CE Class 1 ISO 60601-1 medically approved product. The ForeSite SS Tablet comes with preinstalled ForeSite SS software and is intended as a secure, easy-to-use, pressure mapping specific device. This system is intended for clinicians in a hospital setting who require secure devices with user password protection, encrypted patient files, and the ability to pressure map without cables connecting the Tablet to the sensor. The sensors come connected to the X4 Sensor Packs and have the option to transmit data to the ForeSite SS Tablet via Bluetooth (alternatively, you have the choice to use the system via a wired USB connection). High resolution sensors are critical to seeing surfaces pressures and making informed recommendations.\n\nSTATEMENT OF WORK PART C   SUPPORTING INFORMATION \n\nC.1 Place of Performance   Washington DC VA Medical Center located at 50 Irving St NW, Washington, DC 20422. Delivery vehicles shall keep traffic disruptions to a minimum.  Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times. \n\nC.2 Period of Performance   Vendor will provide equipment within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM   430PM The Contractor shall perform all services during normal business hours.  \n\nRESPONSES:  \n\nPlease include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.  \n\nPlease provide any product solution or configuration so long as they are equivalent to the brand name product.  \n\nResponses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.  \n\nPLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:  \n\nFull name and address of company \n\nDUNS number/ CAGE Code/ SAM UEI \n\nBusiness Size \n\nManufacturer or Distributor  \n\nIf distributor, provide full name, business size, and address of manufacturer.  \n\nCountry of Origin designation for all products. \n\nTechnical Literature that clearly shows product(s) are equivalent.  \n\nAny additional product solution or configuration that would be beneficial to the functionality of the product line identified.   \n\nAuthorized Distributor Letter Certified by OEM with a current date.  \n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. \nDISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"contacts":[{"name":"Alison Klein","role":"primary","email":"Alison.Klein@va.gov","phone":"(304) 623-3461 x4143","title":"Contract Officer"}],"place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs VAMC","street2":"50 Irving St NW"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"e60982e948dc4280b9cfe345902eafd1","name":"36C24526Q0640_1.docx","kind":"file","mime_type":".docx","size_bytes":19310,"posted_at":"2026-07-07T14:57:32.135Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e60982e948dc4280b9cfe345902eafd1/download","mirrored":false}],"awards":[],"related":[{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"W911S227U0170","latest_notice_id":"8e384efad4304afa9f8a55c7438674ba","title":"MEDICAL EQUIPMENT AND SUPPLIES","solicitation_number":"W911S227U0170","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-25T06:17:21.102542Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":17,"indexable":false}