{"canonical":"https://sealedbidder.com/opportunities/36c24526q0620","key":"36C24526Q0620","url":"https://sealedbidder.com/opportunities/36c24526q0620","title":"6515--Bipolar ESU","solicitation_number":"36C24526Q0620","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-10T16:00:00Z","first_posted":"2026-06-24","last_posted":"2026-06-24","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334510","psc":"6515","set_aside":null,"place_state":"WV","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"54033","place_county_name":"Harrison County","place_city":"5415628","place_city_name":"Clarksburg","winner":null,"award_amount":null,"publications":[{"notice_id":"eebf739b5f86498eb7091a44cf87e54e","title":"6515--Bipolar ESU","solicitation_number":"36C24526Q0620","notice_type":"r","base_type":"r","posted":"2026-06-24","posted_at":"2026-06-24T17:44:31.056Z","due_at":"2026-07-10T16:00:00Z","due_date":"2026-07-10","cancelled":false,"archived":true,"archive_date":"2026-09-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eebf739b5f86498eb7091a44cf87e54e/view","enriched":true,"history":[{"index":3,"title":"6515--Bipolar ESU","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-24T17:44:31.056Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"eebf739b5f86498eb7091a44cf87e54e","solicitation_number":"36C24526Q0620"}]}],"latest_notice_id":"eebf739b5f86498eb7091a44cf87e54e","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-24","posted_at":"2026-06-24T17:44:31.056Z","created_at":"2026-06-24T17:44:28.822Z","modified_at":"2026-09-08T05:07:19.167Z","response_deadline":{"raw":"2026-07-10T12:00:00-04:00","utc":"2026-07-10T16:00:00Z","date":"2026-07-10","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eebf739b5f86498eb7091a44cf87e54e/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--Bipolar ESU","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Bipolar ESU","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-24T17:44:31.056Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"eebf739b5f86498eb7091a44cf87e54e","solicitation_number":"36C24526Q0620"}],"contacts":[{"fax":"CHARLES CAMERON","name":"ALISON KLEIN","role":"primary","email":"ALISON.KLEIN@VA.GOV","phone":"304-623-3461 X 4143","title":"CONTRACTING OFFICER"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"eebf739b5f86498eb7091a44cf87e54e","lineage_id":"eebf739b5f86498eb7091a44cf87e54e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-01T02:33:48.730841926Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"0ecd2c7199e27191297b28c093ef6fa3d3711b3f70e199d081a67528d9e900b1","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-01T02:33:48.730841926Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â  Any resulting procurement action will be the subject of a separate, future announcement.Â  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs, located at LOUIS A. JOHNSON VA Medical Center located at 1 MEDICAL CENTER DRIVE, CLARKSBURG WV 26301 is seeking an Aesculap Bipolar Generator GN160\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1250 employees.\nSalient Characteristics:\nTechnical Requirements \nThe procurement is for a quantity of two (2) bipolar generators and necessary accessories.\nDual voltage operation: 100 120 V or 220 240 V, 50/60 Hz \nCompact and portable: 305 Ã— 135 Ã— 325 mm, weight approximately 6 kg \nCE-marked and compliant with IEC standards for electromagnetic safety and patient protection \nAccessories shall include:\nTwo (2) foot switches, one (1) for each generator.\nTwo (2) power cords, one (1) for each generator.\nTwo (2) boxes of disposable bipolar forceps plugs, one (1) for each generator\nThe generators shall have real time current and flow measurement.\nThe generators shall have a micro power range of 0.1 to 9.9 watts, adjustable in 0.1W increments.\nThe generators shall have a macro power range of 1 to 50 watts, adjustable in 1W increments.\nContractor shall provide two copies of the operating and service manuals.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use   IFU) for the Government to determine the ability of the facility to properly process the equipment.\n\n\n\nTechnology & Safety\nMicroprocessor-controlled, AC impedance adaptive system that actively reduces power to prevent tissue carbonization and forceps sticking during coagulation \nOptimized  Non Stick Bipolar  performance: real-time monitoring adjusts coagulation parameters to avoid sparking and hot-spots, enhancing safety and efficiency \n\nOperating Modes & Power Output\nTwo selectable modes: \n1.STANDARD (default): delivers rapid coagulation across the full range while limiting voltage based on measured tissue resistance \nFORCED: offers a different impedance curve for more aggressive coagulation when needed \nPower settings range from 1 60 DOSIS (dose units), equivalent to 10 170 mA, adjusted via a rotary control that can be toggled between DOSIS and MALIS scales \n\nUser Interface & Controls\nFront panel includes a clear digital display for mode and setting readout (DOSIS/MALIS).\nRotary knob with push-button: adjusts power level and toggles operational settings \nFeatures a single-pedal footswitch (either round GN161 or squared GK226) for activation \n\n\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nContractor is to provide the COR with shipment tracking information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device\nTraining shall be on-site for one day.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include preventative maintenance of the system.\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer s names of the personnel performing work, and the date service was provided.\n\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â Any resulting procurement action will be the subject of a separate, future announcement.Â The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs, located at LOUIS A. JOHNSON VA Medical Center located at 1 MEDICAL CENTER DRIVE, CLARKSBURG WV 26301 is seeking an Aesculap Bipolar Generator GN160\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1250 employees.\nSalient Characteristics:\nTechnical Requirements\nThe procurement is for a quantity of two (2) bipolar generators and necessary accessories.\nDual voltage operation: 100 120 V or 220 240 V, 50/60 Hz\nCompact and portable: 305 Ã— 135 Ã— 325 mm, weight approximately 6 kg\nCE-marked and compliant with IEC standards for electromagnetic safety and patient protection\nAccessories shall include:\nTwo (2) foot switches, one (1) for each generator.\nTwo (2) power cords, one (1) for each generator.\nTwo (2) boxes of disposable bipolar forceps plugs, one (1) for each generator\nThe generators shall have real time current and flow measurement.\nThe generators shall have a micro power range of 0.1 to 9.9 watts, adjustable in 0.1W increments.\nThe generators shall have a macro power range of 1 to 50 watts, adjustable in 1W increments.\nContractor shall provide two copies of the operating and service manuals.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use IFU) for the Government to determine the ability of the facility to properly process the equipment.\n\nTechnology & Safety\nMicroprocessor-controlled, AC impedance adaptive system that actively reduces power to prevent tissue carbonization and forceps sticking during coagulation\nOptimized Non Stick Bipolar performance: real-time monitoring adjusts coagulation parameters to avoid sparking and hot-spots, enhancing safety and efficiency\n\nOperating Modes & Power Output\nTwo selectable modes:\n1.STANDARD (default): delivers rapid coagulation across the full range while limiting voltage based on measured tissue resistance\nFORCED: offers a different impedance curve for more aggressive coagulation when needed\nPower settings range from 1 60 DOSIS (dose units), equivalent to 10 170 mA, adjusted via a rotary control that can be toggled between DOSIS and MALIS scales\n\nUser Interface & Controls\nFront panel includes a clear digital display for mode and setting readout (DOSIS/MALIS).\nRotary knob with push-button: adjusts power level and toggles operational settings\nFeatures a single-pedal footswitch (either round GN161 or squared GK226) for activation\n\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nContractor is to provide the COR with shipment tracking information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device\nTraining shall be on-site for one day.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include preventative maintenance of the system.\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer s names of the personnel performing work, and the date service was provided.\n\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0620","place_of_performance":{"zip":"26301","city":{"name":"CLARKSBURG,"},"state":{"code":"WV","name":"West Virginia"},"street":"LOUIS A. JOHNSON VAMC 1 MEDICAL CENTER DR","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2026-07-10T16:00:00Z","due_date":"2026-07-10","closes_at":"2026-07-10T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-01T03:19:44.961615Z","principal_notice_id":"eebf739b5f86498eb7091a44cf87e54e","description":{"text":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â Any resulting procurement action will be the subject of a separate, future announcement.Â The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs, located at LOUIS A. JOHNSON VA Medical Center located at 1 MEDICAL CENTER DRIVE, CLARKSBURG WV 26301 is seeking an Aesculap Bipolar Generator GN160\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1250 employees.\nSalient Characteristics:\nTechnical Requirements\nThe procurement is for a quantity of two (2) bipolar generators and necessary accessories.\nDual voltage operation: 100 120 V or 220 240 V, 50/60 Hz\nCompact and portable: 305 Ã— 135 Ã— 325 mm, weight approximately 6 kg\nCE-marked and compliant with IEC standards for electromagnetic safety and patient protection\nAccessories shall include:\nTwo (2) foot switches, one (1) for each generator.\nTwo (2) power cords, one (1) for each generator.\nTwo (2) boxes of disposable bipolar forceps plugs, one (1) for each generator\nThe generators shall have real time current and flow measurement.\nThe generators shall have a micro power range of 0.1 to 9.9 watts, adjustable in 0.1W increments.\nThe generators shall have a macro power range of 1 to 50 watts, adjustable in 1W increments.\nContractor shall provide two copies of the operating and service manuals.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use IFU) for the Government to determine the ability of the facility to properly process the equipment.\n\nTechnology & Safety\nMicroprocessor-controlled, AC impedance adaptive system that actively reduces power to prevent tissue carbonization and forceps sticking during coagulation\nOptimized Non Stick Bipolar performance: real-time monitoring adjusts coagulation parameters to avoid sparking and hot-spots, enhancing safety and efficiency\n\nOperating Modes & Power Output\nTwo selectable modes:\n1.STANDARD (default): delivers rapid coagulation across the full range while limiting voltage based on measured tissue resistance\nFORCED: offers a different impedance curve for more aggressive coagulation when needed\nPower settings range from 1 60 DOSIS (dose units), equivalent to 10 170 mA, adjusted via a rotary control that can be toggled between DOSIS and MALIS scales\n\nUser Interface & Controls\nFront panel includes a clear digital display for mode and setting readout (DOSIS/MALIS).\nRotary knob with push-button: adjusts power level and toggles operational settings\nFeatures a single-pedal footswitch (either round GN161 or squared GK226) for activation\n\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nContractor is to provide the COR with shipment tracking information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device\nTraining shall be on-site for one day.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include preventative maintenance of the system.\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer s names of the personnel performing work, and the date service was provided.\n\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â  Any resulting procurement action will be the subject of a separate, future announcement.Â  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs, located at LOUIS A. JOHNSON VA Medical Center located at 1 MEDICAL CENTER DRIVE, CLARKSBURG WV 26301 is seeking an Aesculap Bipolar Generator GN160\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1250 employees.\nSalient Characteristics:\nTechnical Requirements \nThe procurement is for a quantity of two (2) bipolar generators and necessary accessories.\nDual voltage operation: 100 120 V or 220 240 V, 50/60 Hz \nCompact and portable: 305 Ã— 135 Ã— 325 mm, weight approximately 6 kg \nCE-marked and compliant with IEC standards for electromagnetic safety and patient protection \nAccessories shall include:\nTwo (2) foot switches, one (1) for each generator.\nTwo (2) power cords, one (1) for each generator.\nTwo (2) boxes of disposable bipolar forceps plugs, one (1) for each generator\nThe generators shall have real time current and flow measurement.\nThe generators shall have a micro power range of 0.1 to 9.9 watts, adjustable in 0.1W increments.\nThe generators shall have a macro power range of 1 to 50 watts, adjustable in 1W increments.\nContractor shall provide two copies of the operating and service manuals.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use   IFU) for the Government to determine the ability of the facility to properly process the equipment.\n\n\n\nTechnology & Safety\nMicroprocessor-controlled, AC impedance adaptive system that actively reduces power to prevent tissue carbonization and forceps sticking during coagulation \nOptimized  Non Stick Bipolar  performance: real-time monitoring adjusts coagulation parameters to avoid sparking and hot-spots, enhancing safety and efficiency \n\nOperating Modes & Power Output\nTwo selectable modes: \n1.STANDARD (default): delivers rapid coagulation across the full range while limiting voltage based on measured tissue resistance \nFORCED: offers a different impedance curve for more aggressive coagulation when needed \nPower settings range from 1 60 DOSIS (dose units), equivalent to 10 170 mA, adjusted via a rotary control that can be toggled between DOSIS and MALIS scales \n\nUser Interface & Controls\nFront panel includes a clear digital display for mode and setting readout (DOSIS/MALIS).\nRotary knob with push-button: adjusts power level and toggles operational settings \nFeatures a single-pedal footswitch (either round GN161 or squared GK226) for activation \n\n\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nContractor is to provide the COR with shipment tracking information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device\nTraining shall be on-site for one day.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include preventative maintenance of the system.\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer s names of the personnel performing work, and the date service was provided.\n\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"fax":"CHARLES CAMERON","name":"ALISON KLEIN","role":"primary","email":"ALISON.KLEIN@VA.GOV","phone":"304-623-3461 X 4143","title":"CONTRACTING OFFICER"}],"place_of_performance":{"zip":"26301","city":{"name":"CLARKSBURG,"},"state":{"code":"WV","name":"West Virginia"},"street":"LOUIS A. JOHNSON VAMC 1 MEDICAL CENTER DR","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"f45ad43cfee24a148a7ab80c7ccbca18","name":"36C24526Q0620.docx","kind":"file","mime_type":".docx","size_bytes":24533,"posted_at":"2026-06-24T17:44:31.056Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f45ad43cfee24a148a7ab80c7ccbca18/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"REQTIHS202600220","latest_notice_id":"ef16a1513b85491d928fcb190b3fe772","title":"Vital Signs Monitoring and Physical Assessment Units","solicitation_number":"REQT-IHS-2026-00220","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-26T01:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H713","office_name":"INDIAN HEALTH SERVICE","naics":"334510","psc":"6515","set_aside":null,"state":"OR","county":"41047","county_name":"Marion County","city":"4164900","city_name":"Salem","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open_total":12,"indexable":false}