{"canonical":"https://sealedbidder.com/opportunities/36c24526q0454","key":"36C24526Q0454","url":"https://sealedbidder.com/opportunities/36c24526q0454","title":"6515--Parathyroid Detection System [PTeye]","solicitation_number":"36C24526Q0454","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-14T16:00:00Z","first_posted":"2026-05-04","last_posted":"2026-05-04","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":"DC","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"11001","place_county_name":"District of Columbia","place_city":"1150000","place_city_name":"Washington","winner":null,"award_amount":null,"publications":[{"notice_id":"70ddf788963d46fea5b372f4180f94ce","title":"6515--Parathyroid Detection System [PTeye]","solicitation_number":"36C24526Q0454","notice_type":"r","base_type":"r","posted":"2026-05-04","posted_at":"2026-05-04T15:25:35.897Z","due_at":"2026-05-14T16:00:00Z","due_date":"2026-05-14","cancelled":false,"archived":true,"archive_date":"2026-07-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/70ddf788963d46fea5b372f4180f94ce/view","enriched":true,"history":[{"index":3,"title":"6515--Parathyroid Detection System [PTeye]","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-04T15:25:35.897Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"70ddf788963d46fea5b372f4180f94ce","solicitation_number":"36C24526Q0454"}]}],"latest_notice_id":"70ddf788963d46fea5b372f4180f94ce","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-05-04","posted_at":"2026-05-04T15:25:35.897Z","created_at":"2026-05-04T15:25:33.691Z","modified_at":"2026-07-14T03:55:53.429Z","response_deadline":{"raw":"2026-05-14T12:00:00-04:00","utc":"2026-05-14T16:00:00Z","date":"2026-05-14","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/70ddf788963d46fea5b372f4180f94ce/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Parathyroid Detection System [PTeye]","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Parathyroid Detection System [PTeye]","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-04T15:25:35.897Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"70ddf788963d46fea5b372f4180f94ce","solicitation_number":"36C24526Q0454"}],"contacts":[{"name":"Dylan Gore","role":"primary","email":"Dylan.Gore@va.gov","phone":"202-382-2807","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"70ddf788963d46fea5b372f4180f94ce","lineage_id":"70ddf788963d46fea5b372f4180f94ce","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T09:31:58.641297181Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"1ccad02008d104d31064e44392e1fab5235319d5b72e436a55f87ad27e9b1731","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T09:31:58.641297181Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Sources Sought Notice\n\nPage 3 of 3\nSources Sought Notice\n\nPage 1 of 3\nThis notice is for planning purposes only and shall not be considered an invitation for bid, request for quotation, request for proposal, or as an obligation of the government to acquire any products or services. Responses to this notice will be used for informational purposes only and only for Network Contracting Office 5. No entitlement to payment of direct or indirect costs from the government will arise as a result from a response to this announcement. No contract will be awarded from this notice.\nThe information requested in this notice will be used to determine available sources of Parathyroid Detection Systems and place(s) of manufacture.\nNorth American Industry Classification System (NAICS) number is 339112.\nContractors that deem themselves capable of meeting the requirement shall provide the below information to Dylan Gore, Contract Specialist, at dylan.gore@va.gov no-later-than May 14, 2026 at 12:00 PM, Eastern Time.\nThe Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office (NCO) 5 is seeking sources for the following procurement:\n\n\nThe Contractor(s) shall provide all labor and supplies associated with the following:\n\nPart #    Description            Quantity \nPT102       Bundle PTeye Basic             ..   .     .  1\nPTCUG-ENUS  .User Guide PTCUG-ENUS PTeye Console ENUS         ..1\nPTeye      Console PTeye                .       .   ..1\nPTeye-2     .Foot pedal PTeye-2                   ..     1\nPTeye-3     .Power Supply PTeye-3 120V-240V...         ..      .1\nPTeye-4     .Power Cord PTeye-4 US 6FT              .     ..1\n*Manufacturer s Warranty, Installation & Training Included\n\n\n\nTechnical Requirements:\nMust be a Dye-Free intraoperative, probe-based technology for identification of parathyroid tissue\nMust use near-infrared (NIR) autofluorescence \nMust have a non-ionizing laser with an NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue \nMust be compatible with single-use probes\n\nEnvironmental Requirements:\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\n\nDelivery Requirements:\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nDelivery is required within 90 days from award of the contract\nOrder shall be delivered to: \n\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\n\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this sources sought (339112)?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a small business and an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nPlease submit capabilities regarding the salient characteristics provided and any other information for planning purposes.\nThis request for information/sources sought notice is for planning purposes ONLY.  The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.).  VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.\n\n\n\n\n\nSTATEMENT OF WORK (SOW)\nFollow-on to Contract and Task Order Number:\nNot applicable\n\nContract Title.  PTeye Parathyroid Detection Equipment  (Brand-Name or Equal)\n\nBackground.  The DC VA Medical Center has a need for an FDA-approved parathyroid detection system to aid during surgical cases. Without this technology there is a risk of inadvertent removal of parathyroid gland tissue leading to an increase in the morbidity of the surgery. Currently, during cases the surgeon is dependent on results from the lab to continue surgery.  Time waiting for the pathologist to provide frozen section analysis of tissue or for the laboratory to perform intra-operative PTH hormone assays prolong surgery times.  Access to this technology reduces risk and operative time localizing parathyroid glands during surgery for hyperparathyroidism (parathyroidectomy). The surgeons at the DCVAMC have trialed and been trained on the requested equipment.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\n\nLine Item Description \nQuantity\nPTEYE Bundle\n1\nUser GUIDE PTCUG-ENUS PTEYE\n\nConsole PTeye\n\nFootpedal PTeye-2\n\nPower supply PTeye-3 120v-240v\n\nPower cord PTeye-4 us 6ft \n\nPTeye Single Use Probe\n\n\n\n\n4.2 Required Features\nDye-Free intraoperative , probe based technology for identification of parathyroid tissue. \n Must use near-infrared (NIR) autofluorescence \nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue \nMust use single use probes\n\nSpecific Tasks.  \n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work. \nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n5.5 Inspection and Acceptance. \nContractor shall conduct a joint inspection with the on-site POC upon completion of installation. \nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.  \n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays: \nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nInvoicing.  \nContractor shall submit a consolidated invoice monthly in arrears of the month for which services are being billed. One all-inclusive monthly invoice shall be provided, which shall contain an invoice number, contract number, obligations order number, and an itemized list of services provided. An acceptable master (all-inclusive) itemized list of services shall be agreed to between the Contractor and the COR prior to submission of the first invoice. \n\nAll invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. \nVA s Electronic Invoice Presentment and Payment System (IPPS)   The VA Financial Services Center (FSC) uses a third-party contractor, Tungsten, to transition vendors from paper to electronic invoice submission. Please go to this website to begin submitting electronic invoices, free of charge: \nhttp://www.tungsten-network.com/US/en/veterans-affairs/.\n\nMore information on the VA FSC is available at: http://www.fsc.va.gov/einvoice.asp.\n\nVendor e-Invoice Set-Up Information:\nTo begin submitting your electronic invoices to the VA FSC for payment processing, free of charge, please contact Tungsten at the below phone number or email address:\nTungsten e-Invoice Setup Information: 1-877-489-6135\nTungsten e-Invoice Email: VA.Registration@Tungsten-Network.com\n\nIf you have a question about the e-invoicing program or Tungsten, please contact the FSC at the below phone number email address. \nFSC e-Invoice Contact Information: 1-877-353-9791\nFSC e-Invoice Email: vafsccshd@va.gov\n\nContract Type. \nFirm-Fixed Priced Contract\n\nEvaluation Factors.\nRequired Features\nPrice\nAuthorization Letter to Distribute\nDelivery Lead Times\n\n\n\nSalient Characteristics \n\nDefinition of salient Characteristics: Those qualities of an item(s) that are essential to ensure that the intended use of the item can be satisfactorily realized.\nCommon Nomenclature (Commercial Description-Please Add Brand Name or Equal to) of Equipment or Supply:   ____Brand name or Equal to The PTeye Parathyroid Detection System _________________\n\nWhat is the country of manufacture (if multiple items, we need multiple countries where the items are made_____Country of Manufacture: United States (USA)_____\n\n\nIs Brand name or Equal to Acceptable if meeting the Salient characteristics needs: Yes _X_ No____\n\nIs a Specific type of material needed: Yes_______ No __X_____________\n\nDescribe What you want the equipment/supply to do (Principal Operation) \nThe requested equipment must be a Dye-FreeÂ intraoperativeÂ ,Â probe basedÂ technology for identification of parathyroid tissue.Â Â Identification of the tissue must use near-infrared (NIR)Â autofluorescence for tissue identification. \n\nEquipment/Supply/Instrument\nDimensions (what is the space requirement for the product?): N/A \nHeight Minimum ___to Maximum Bottom__ \nWidth Minimum __ to Maximum Bottom__\nDepth Minimum __to Maximum Bottom__\nWeight Minimum _to Maximum ______\n\nDisplay/Monitor/Screen:\nDisplay that indicates if the laser is on\nDisplays visual feedback when in contact with tissue  \n\nSoftware Required/associated with this purchase?\nNo\nEnvironmental Considerations: Yes __X_No______\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\n\n\nWorking Volume/ Product Performance/Additional requirements: \nMustÂ have a non-ionizing laser with aÂ NIR atÂ noÂ higher thanÂ 785nmÂ \nMust generate bothÂ visual andÂ audibleÂ indicationÂ whenÂ detecting parathyroid tissueÂ Â \n\nAccessories/Consumables: Yes __X__No__\nIf yes what? ____Must be compatible with single use probes\n\nWarranty and Parts/Service Requirements:\nMinimum Warranty Months/Years______1 year minimum___________________________________\nParts/Service/Support options: ________1 year minimum ___________________________________\n\n\nAdditional instructions/Needs/Specifications:\nMust use near-infrared (NIR) autofluorescence  \nMust have a non-ionizing laser with a NIR at no higher than 785nm \nMust be FDA approved\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue \nMust generate both visual and audible indication when detecting parathyroid tissue  \nMust use single use probes\n\nOther pertinent information that describes the item, material or service needed:\n_______N/A______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________\n\nIf this is replacement equipment, original equipment, original manufacturer, and manufacturer part number if known:\n\n PTeye  parathyroid detection system, manufactured by Medtronic","text":"Sources Sought Notice\n\nPage 3 of 3\nSources Sought Notice\n\nPage 1 of 3\nThis notice is for planning purposes only and shall not be considered an invitation for bid, request for quotation, request for proposal, or as an obligation of the government to acquire any products or services. Responses to this notice will be used for informational purposes only and only for Network Contracting Office 5. No entitlement to payment of direct or indirect costs from the government will arise as a result from a response to this announcement. No contract will be awarded from this notice.\nThe information requested in this notice will be used to determine available sources of Parathyroid Detection Systems and place(s) of manufacture.\nNorth American Industry Classification System (NAICS) number is 339112.\nContractors that deem themselves capable of meeting the requirement shall provide the below information to Dylan Gore, Contract Specialist, at dylan.gore@va.gov no-later-than May 14, 2026 at 12:00 PM, Eastern Time.\nThe Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office (NCO) 5 is seeking sources for the following procurement:\n\nThe Contractor(s) shall provide all labor and supplies associated with the following:\n\nPart # Description Quantity\nPT102 Bundle PTeye Basic .. . . 1\nPTCUG-ENUS .User Guide PTCUG-ENUS PTeye Console ENUS ..1\nPTeye Console PTeye . . ..1\nPTeye-2 .Foot pedal PTeye-2 .. 1\nPTeye-3 .Power Supply PTeye-3 120V-240V... .. .1\nPTeye-4 .Power Cord PTeye-4 US 6FT . ..1\n*Manufacturer s Warranty, Installation & Training Included\n\nTechnical Requirements:\nMust be a Dye-Free intraoperative, probe-based technology for identification of parathyroid tissue\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with an NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust be compatible with single-use probes\n\nEnvironmental Requirements:\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\nDelivery Requirements:\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nDelivery is required within 90 days from award of the contract\nOrder shall be delivered to:\n\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\n\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this sources sought (339112)?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a small business and an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nPlease submit capabilities regarding the salient characteristics provided and any other information for planning purposes.\nThis request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.\n\nSTATEMENT OF WORK (SOW)\nFollow-on to Contract and Task Order Number:\nNot applicable\n\nContract Title. PTeye Parathyroid Detection Equipment (Brand-Name or Equal)\n\nBackground. The DC VA Medical Center has a need for an FDA-approved parathyroid detection system to aid during surgical cases. Without this technology there is a risk of inadvertent removal of parathyroid gland tissue leading to an increase in the morbidity of the surgery. Currently, during cases the surgeon is dependent on results from the lab to continue surgery. Time waiting for the pathologist to provide frozen section analysis of tissue or for the laboratory to perform intra-operative PTH hormone assays prolong surgery times. Access to this technology reduces risk and operative time localizing parathyroid glands during surgery for hyperparathyroidism (parathyroidectomy). The surgeons at the DCVAMC have trialed and been trained on the requested equipment.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nPTEYE Bundle\n1\nUser GUIDE PTCUG-ENUS PTEYE\n\nConsole PTeye\n\nFootpedal PTeye-2\n\nPower supply PTeye-3 120v-240v\n\nPower cord PTeye-4 us 6ft\n\nPTeye Single Use Probe\n\n4.2 Required Features\nDye-Free intraoperative , probe based technology for identification of parathyroid tissue.\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust use single use probes\n\nSpecific Tasks.\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\n5.5 Inspection and Acceptance.\nContractor shall conduct a joint inspection with the on-site POC upon completion of installation.\nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.\n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays:\nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nInvoicing.\nContractor shall submit a consolidated invoice monthly in arrears of the month for which services are being billed. One all-inclusive monthly invoice shall be provided, which shall contain an invoice number, contract number, obligations order number, and an itemized list of services provided. An acceptable master (all-inclusive) itemized list of services shall be agreed to between the Contractor and the COR prior to submission of the first invoice.\n\nAll invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests.\nVA s Electronic Invoice Presentment and Payment System (IPPS) The VA Financial Services Center (FSC) uses a third-party contractor, Tungsten, to transition vendors from paper to electronic invoice submission. Please go to this website to begin submitting electronic invoices, free of charge:\nhttp://www.tungsten-network.com/US/en/veterans-affairs/.\n\nMore information on the VA FSC is available at: http://www.fsc.va.gov/einvoice.asp.\n\nVendor e-Invoice Set-Up Information:\nTo begin submitting your electronic invoices to the VA FSC for payment processing, free of charge, please contact Tungsten at the below phone number or email address:\nTungsten e-Invoice Setup Information: 1-877-489-6135\nTungsten e-Invoice Email: VA.Registration@Tungsten-Network.com\n\nIf you have a question about the e-invoicing program or Tungsten, please contact the FSC at the below phone number email address.\nFSC e-Invoice Contact Information: 1-877-353-9791\nFSC e-Invoice Email: vafsccshd@va.gov\n\nContract Type.\nFirm-Fixed Priced Contract\n\nEvaluation Factors.\nRequired Features\nPrice\nAuthorization Letter to Distribute\nDelivery Lead Times\n\nSalient Characteristics\n\nDefinition of salient Characteristics: Those qualities of an item(s) that are essential to ensure that the intended use of the item can be satisfactorily realized.\nCommon Nomenclature (Commercial Description-Please Add Brand Name or Equal to) of Equipment or Supply: ____Brand name or Equal to The PTeye Parathyroid Detection System _________________\n\nWhat is the country of manufacture (if multiple items, we need multiple countries where the items are made_____Country of Manufacture: United States (USA)_____\n\nIs Brand name or Equal to Acceptable if meeting the Salient characteristics needs: Yes _X_ No____\n\nIs a Specific type of material needed: Yes_______ No __X_____________\n\nDescribe What you want the equipment/supply to do (Principal Operation)\nThe requested equipment must be a Dye-FreeÂ intraoperativeÂ ,Â probe basedÂ technology for identification of parathyroid tissue.Â Â Identification of the tissue must use near-infrared (NIR)Â autofluorescence for tissue identification.\n\nEquipment/Supply/Instrument\nDimensions (what is the space requirement for the product?): N/A\nHeight Minimum ___to Maximum Bottom__\nWidth Minimum __ to Maximum Bottom__\nDepth Minimum __to Maximum Bottom__\nWeight Minimum _to Maximum ______\n\nDisplay/Monitor/Screen:\nDisplay that indicates if the laser is on\nDisplays visual feedback when in contact with tissue\n\nSoftware Required/associated with this purchase?\nNo\nEnvironmental Considerations: Yes __X_No______\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\nWorking Volume/ Product Performance/Additional requirements:\nMustÂ have a non-ionizing laser with aÂ NIR atÂ noÂ higher thanÂ 785nmÂ\nMust generate bothÂ visual andÂ audibleÂ indicationÂ whenÂ detecting parathyroid tissueÂ Â\n\nAccessories/Consumables: Yes __X__No__\nIf yes what? ____Must be compatible with single use probes\n\nWarranty and Parts/Service Requirements:\nMinimum Warranty Months/Years______1 year minimum___________________________________\nParts/Service/Support options: ________1 year minimum ___________________________________\n\nAdditional instructions/Needs/Specifications:\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust be FDA approved\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust use single use probes\n\nOther pertinent information that describes the item, material or service needed:\n_______N/A______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________\n\nIf this is replacement equipment, original equipment, original manufacturer, and manufacturer part number if known:\n\nPTeye parathyroid detection system, manufactured by Medtronic","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0454","place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VA Medical Center","street2":"50 Irving Street NW"},"product_service_code":"6515"}],"due_at":"2026-05-14T16:00:00Z","due_date":"2026-05-14","closes_at":"2026-05-14T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-05T09:52:22.414744Z","principal_notice_id":"70ddf788963d46fea5b372f4180f94ce","description":{"text":"Sources Sought Notice\n\nPage 3 of 3\nSources Sought Notice\n\nPage 1 of 3\nThis notice is for planning purposes only and shall not be considered an invitation for bid, request for quotation, request for proposal, or as an obligation of the government to acquire any products or services. Responses to this notice will be used for informational purposes only and only for Network Contracting Office 5. No entitlement to payment of direct or indirect costs from the government will arise as a result from a response to this announcement. No contract will be awarded from this notice.\nThe information requested in this notice will be used to determine available sources of Parathyroid Detection Systems and place(s) of manufacture.\nNorth American Industry Classification System (NAICS) number is 339112.\nContractors that deem themselves capable of meeting the requirement shall provide the below information to Dylan Gore, Contract Specialist, at dylan.gore@va.gov no-later-than May 14, 2026 at 12:00 PM, Eastern Time.\nThe Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office (NCO) 5 is seeking sources for the following procurement:\n\nThe Contractor(s) shall provide all labor and supplies associated with the following:\n\nPart # Description Quantity\nPT102 Bundle PTeye Basic .. . . 1\nPTCUG-ENUS .User Guide PTCUG-ENUS PTeye Console ENUS ..1\nPTeye Console PTeye . . ..1\nPTeye-2 .Foot pedal PTeye-2 .. 1\nPTeye-3 .Power Supply PTeye-3 120V-240V... .. .1\nPTeye-4 .Power Cord PTeye-4 US 6FT . ..1\n*Manufacturer s Warranty, Installation & Training Included\n\nTechnical Requirements:\nMust be a Dye-Free intraoperative, probe-based technology for identification of parathyroid tissue\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with an NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust be compatible with single-use probes\n\nEnvironmental Requirements:\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\nDelivery Requirements:\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nDelivery is required within 90 days from award of the contract\nOrder shall be delivered to:\n\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\n\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this sources sought (339112)?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a small business and an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nPlease submit capabilities regarding the salient characteristics provided and any other information for planning purposes.\nThis request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.\n\nSTATEMENT OF WORK (SOW)\nFollow-on to Contract and Task Order Number:\nNot applicable\n\nContract Title. PTeye Parathyroid Detection Equipment (Brand-Name or Equal)\n\nBackground. The DC VA Medical Center has a need for an FDA-approved parathyroid detection system to aid during surgical cases. Without this technology there is a risk of inadvertent removal of parathyroid gland tissue leading to an increase in the morbidity of the surgery. Currently, during cases the surgeon is dependent on results from the lab to continue surgery. Time waiting for the pathologist to provide frozen section analysis of tissue or for the laboratory to perform intra-operative PTH hormone assays prolong surgery times. Access to this technology reduces risk and operative time localizing parathyroid glands during surgery for hyperparathyroidism (parathyroidectomy). The surgeons at the DCVAMC have trialed and been trained on the requested equipment.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.\n\nSpecifications.\n4.1 Equipment\n\nLine Item Description\nQuantity\nPTEYE Bundle\n1\nUser GUIDE PTCUG-ENUS PTEYE\n\nConsole PTeye\n\nFootpedal PTeye-2\n\nPower supply PTeye-3 120v-240v\n\nPower cord PTeye-4 us 6ft\n\nPTeye Single Use Probe\n\n4.2 Required Features\nDye-Free intraoperative , probe based technology for identification of parathyroid tissue.\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust use single use probes\n\nSpecific Tasks.\n5.1 Delivery.\nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip).\nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery.\nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines.\nMask Requirement: All contractors shall wear masks while indoors.\nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials.\nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work.\nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection.\n\n5.3 Installation/Implementation.\nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system.\nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use.\nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer.\n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users.\nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation.\nEducation professional shall be certified to provide instruction on the designated equipment/system.\nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips.\n\n5.5 Inspection and Acceptance.\nContractor shall conduct a joint inspection with the on-site POC upon completion of installation.\nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.\n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays:\nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nInvoicing.\nContractor shall submit a consolidated invoice monthly in arrears of the month for which services are being billed. One all-inclusive monthly invoice shall be provided, which shall contain an invoice number, contract number, obligations order number, and an itemized list of services provided. An acceptable master (all-inclusive) itemized list of services shall be agreed to between the Contractor and the COR prior to submission of the first invoice.\n\nAll invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests.\nVA s Electronic Invoice Presentment and Payment System (IPPS) The VA Financial Services Center (FSC) uses a third-party contractor, Tungsten, to transition vendors from paper to electronic invoice submission. Please go to this website to begin submitting electronic invoices, free of charge:\nhttp://www.tungsten-network.com/US/en/veterans-affairs/.\n\nMore information on the VA FSC is available at: http://www.fsc.va.gov/einvoice.asp.\n\nVendor e-Invoice Set-Up Information:\nTo begin submitting your electronic invoices to the VA FSC for payment processing, free of charge, please contact Tungsten at the below phone number or email address:\nTungsten e-Invoice Setup Information: 1-877-489-6135\nTungsten e-Invoice Email: VA.Registration@Tungsten-Network.com\n\nIf you have a question about the e-invoicing program or Tungsten, please contact the FSC at the below phone number email address.\nFSC e-Invoice Contact Information: 1-877-353-9791\nFSC e-Invoice Email: vafsccshd@va.gov\n\nContract Type.\nFirm-Fixed Priced Contract\n\nEvaluation Factors.\nRequired Features\nPrice\nAuthorization Letter to Distribute\nDelivery Lead Times\n\nSalient Characteristics\n\nDefinition of salient Characteristics: Those qualities of an item(s) that are essential to ensure that the intended use of the item can be satisfactorily realized.\nCommon Nomenclature (Commercial Description-Please Add Brand Name or Equal to) of Equipment or Supply: ____Brand name or Equal to The PTeye Parathyroid Detection System _________________\n\nWhat is the country of manufacture (if multiple items, we need multiple countries where the items are made_____Country of Manufacture: United States (USA)_____\n\nIs Brand name or Equal to Acceptable if meeting the Salient characteristics needs: Yes _X_ No____\n\nIs a Specific type of material needed: Yes_______ No __X_____________\n\nDescribe What you want the equipment/supply to do (Principal Operation)\nThe requested equipment must be a Dye-FreeÂ intraoperativeÂ ,Â probe basedÂ technology for identification of parathyroid tissue.Â Â Identification of the tissue must use near-infrared (NIR)Â autofluorescence for tissue identification.\n\nEquipment/Supply/Instrument\nDimensions (what is the space requirement for the product?): N/A\nHeight Minimum ___to Maximum Bottom__\nWidth Minimum __ to Maximum Bottom__\nDepth Minimum __to Maximum Bottom__\nWeight Minimum _to Maximum ______\n\nDisplay/Monitor/Screen:\nDisplay that indicates if the laser is on\nDisplays visual feedback when in contact with tissue\n\nSoftware Required/associated with this purchase?\nNo\nEnvironmental Considerations: Yes __X_No______\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\nWorking Volume/ Product Performance/Additional requirements:\nMustÂ have a non-ionizing laser with aÂ NIR atÂ noÂ higher thanÂ 785nmÂ\nMust generate bothÂ visual andÂ audibleÂ indicationÂ whenÂ detecting parathyroid tissueÂ Â\n\nAccessories/Consumables: Yes __X__No__\nIf yes what? ____Must be compatible with single use probes\n\nWarranty and Parts/Service Requirements:\nMinimum Warranty Months/Years______1 year minimum___________________________________\nParts/Service/Support options: ________1 year minimum ___________________________________\n\nAdditional instructions/Needs/Specifications:\nMust use near-infrared (NIR) autofluorescence\nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust be FDA approved\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue\nMust use single use probes\n\nOther pertinent information that describes the item, material or service needed:\n_______N/A______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________\n\nIf this is replacement equipment, original equipment, original manufacturer, and manufacturer part number if known:\n\nPTeye parathyroid detection system, manufactured by Medtronic","html":"Sources Sought Notice\n\nPage 3 of 3\nSources Sought Notice\n\nPage 1 of 3\nThis notice is for planning purposes only and shall not be considered an invitation for bid, request for quotation, request for proposal, or as an obligation of the government to acquire any products or services. Responses to this notice will be used for informational purposes only and only for Network Contracting Office 5. No entitlement to payment of direct or indirect costs from the government will arise as a result from a response to this announcement. No contract will be awarded from this notice.\nThe information requested in this notice will be used to determine available sources of Parathyroid Detection Systems and place(s) of manufacture.\nNorth American Industry Classification System (NAICS) number is 339112.\nContractors that deem themselves capable of meeting the requirement shall provide the below information to Dylan Gore, Contract Specialist, at dylan.gore@va.gov no-later-than May 14, 2026 at 12:00 PM, Eastern Time.\nThe Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office (NCO) 5 is seeking sources for the following procurement:\n\n\nThe Contractor(s) shall provide all labor and supplies associated with the following:\n\nPart #    Description            Quantity \nPT102       Bundle PTeye Basic             ..   .     .  1\nPTCUG-ENUS  .User Guide PTCUG-ENUS PTeye Console ENUS         ..1\nPTeye      Console PTeye                .       .   ..1\nPTeye-2     .Foot pedal PTeye-2                   ..     1\nPTeye-3     .Power Supply PTeye-3 120V-240V...         ..      .1\nPTeye-4     .Power Cord PTeye-4 US 6FT              .     ..1\n*Manufacturer s Warranty, Installation & Training Included\n\n\n\nTechnical Requirements:\nMust be a Dye-Free intraoperative, probe-based technology for identification of parathyroid tissue\nMust use near-infrared (NIR) autofluorescence \nMust have a non-ionizing laser with an NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue \nMust be compatible with single-use probes\n\nEnvironmental Requirements:\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\n\nDelivery Requirements:\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information.\nDelivery is required within 90 days from award of the contract\nOrder shall be delivered to: \n\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\n\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this sources sought (339112)?\n\nAre you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n\nIf you are a small business and an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nPlease submit capabilities regarding the salient characteristics provided and any other information for planning purposes.\nThis request for information/sources sought notice is for planning purposes ONLY.  The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.).  VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.\n\n\n\n\n\nSTATEMENT OF WORK (SOW)\nFollow-on to Contract and Task Order Number:\nNot applicable\n\nContract Title.  PTeye Parathyroid Detection Equipment  (Brand-Name or Equal)\n\nBackground.  The DC VA Medical Center has a need for an FDA-approved parathyroid detection system to aid during surgical cases. Without this technology there is a risk of inadvertent removal of parathyroid gland tissue leading to an increase in the morbidity of the surgery. Currently, during cases the surgeon is dependent on results from the lab to continue surgery.  Time waiting for the pathologist to provide frozen section analysis of tissue or for the laboratory to perform intra-operative PTH hormone assays prolong surgery times.  Access to this technology reduces risk and operative time localizing parathyroid glands during surgery for hyperparathyroidism (parathyroidectomy). The surgeons at the DCVAMC have trialed and been trained on the requested equipment.\n\nScope of Work. The procurement shall include all parts, materials, labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. \n\nSpecifications.\n4.1 Equipment\n\n\nLine Item Description \nQuantity\nPTEYE Bundle\n1\nUser GUIDE PTCUG-ENUS PTEYE\n\nConsole PTeye\n\nFootpedal PTeye-2\n\nPower supply PTeye-3 120v-240v\n\nPower cord PTeye-4 us 6ft \n\nPTeye Single Use Probe\n\n\n\n\n4.2 Required Features\nDye-Free intraoperative , probe based technology for identification of parathyroid tissue. \n Must use near-infrared (NIR) autofluorescence \nMust have a non-ionizing laser with a NIR at no higher than 785nm\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue\nMust generate both visual and audible indication when detecting parathyroid tissue \nMust use single use probes\n\nSpecific Tasks.  \n5.1 Delivery.  \nAll equipment shall be delivered to:\nWashington DC VA Medical Center\n50 Irving St NW\nWashington, DC 20422\nATTN: VHAWAS Equipment Committee\nContract VA Purchase Order (PO) number shall be included with delivery information (e.g., packing slip). \nNote: PO number starts with station code 688 followed by a letter and 5 digits (e.g., 688A12345)\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nContractor shall coordinate delivery with the on-site Point of Contact (POC) and provide shipment tracking information. \nContractor shall verify delivery date and time with the on-site POC at least 3 business days prior to scheduled delivery. \nDelivery is required within 90 days from award of the contract.\n\n5.2 On Site Procedures.\nCOVID-19 Screening: All persons entering the facility shall be subject to screening for COVID-19 per the current CDC (Center for Disease Control) guidelines. \nMask Requirement: All contractors shall wear masks while indoors. \nContract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government Officials. \nTime spent on site shall be for a period sufficient to complete the work set forth in the statement of work. \nOn site visits shall be scheduled in advance with the designated on-site POC.\nContractor shall check in and out with Biomedical Engineering prior to visiting the worksite for each day of work. \nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy. \nParking: it is the responsibility of the Contractor to park in the appropriate designated parking areas.\nContractor personnel s tool bags are subject to inspection. \n\n5.3 Installation/Implementation.  \nInstallation/Implementation will be completed by personnel certified and knowledgeable with the designated equipment/system. \nInstallation shall be completed within the period of performance.\nContractor shall be responsible for any Personal Protection Equipment (PPE) required when performing work on site.\nContractor shall submit all removable media to be used on a VA system to Biomedical Engineering for scanning with anti-virus software prior to use. \nIn the case turn-in, exchange, repair, or replacement of equipment containing hard drives used by the VA, the hard drives shall be removed from the equipment and remain in possession of the VA (this includes loaned or rented equipment).\nThe contractor shall take all necessary precautions to prevent damage to any government property. The contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken. Any damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the government, upon approval of the Contracting Officer. \n\n5.4 Training.\nContractor shall be responsible for providing training to clinical staff/users. \nTraining is to be scheduled in advance with the designated on-site POC.\nEducation shall be provided prior to and/or at time of installation. \nEducation professional shall be certified to provide instruction on the designated equipment/system. \nEducation curriculum must include: operations and set-up, user maintenance, safety, and user troubleshooting tips. \n\n5.5 Inspection and Acceptance. \nContractor shall conduct a joint inspection with the on-site POC upon completion of installation. \nIn the event deficiencies are identified, the contractor shall provide the date when the identified deficiencies will be addressed if not addressed on the date of installation. The Contractor shall conduct a joint inspection with the on-site POC after addressing all deficiencies. All deficiencies identified in the joint inspections shall be corrected by the Contractor prior to Government acceptance of the item. Any disputes shall be resolved by the Contracting Officer.\n\n5.6 Deliverables.\nThe Contractor shall provide the below documentation for the proposed equipment to VHAWASEquipmentRequests@va.gov within 10 business days of work completion:\nService report.\nWarranty information.\nElectronic copy of the Operators Manual.\nElectronic copies of the complete technical service manuals, including troubleshooting guides, necessary diagnostic software and equipment information, schematic diagrams, and parts lists.  \n\nHours of Operation.\nDC VAMC s normal business hours are Monday-Friday, 8:00 am to 4:30 pm, excluding observed Federal holidays: \nNew Year s Day\nLabor Day\nMartin Luther King s Birthday\nColumbus Day\nPresident s Day\nVeteran s Day\nMemorial Day\nThanksgiving Day\nJuneteenth\nChristmas Day\nIndependence Day\nAny other national holiday as declared by the President of the United States\n\n\nPeriod of Performance. Delivery within 90 days from contract award.\n\nInvoicing.  \nContractor shall submit a consolidated invoice monthly in arrears of the month for which services are being billed. One all-inclusive monthly invoice shall be provided, which shall contain an invoice number, contract number, obligations order number, and an itemized list of services provided. An acceptable master (all-inclusive) itemized list of services shall be agreed to between the Contractor and the COR prior to submission of the first invoice. \n\nAll invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. \nVA s Electronic Invoice Presentment and Payment System (IPPS)   The VA Financial Services Center (FSC) uses a third-party contractor, Tungsten, to transition vendors from paper to electronic invoice submission. Please go to this website to begin submitting electronic invoices, free of charge: \nhttp://www.tungsten-network.com/US/en/veterans-affairs/.\n\nMore information on the VA FSC is available at: http://www.fsc.va.gov/einvoice.asp.\n\nVendor e-Invoice Set-Up Information:\nTo begin submitting your electronic invoices to the VA FSC for payment processing, free of charge, please contact Tungsten at the below phone number or email address:\nTungsten e-Invoice Setup Information: 1-877-489-6135\nTungsten e-Invoice Email: VA.Registration@Tungsten-Network.com\n\nIf you have a question about the e-invoicing program or Tungsten, please contact the FSC at the below phone number email address. \nFSC e-Invoice Contact Information: 1-877-353-9791\nFSC e-Invoice Email: vafsccshd@va.gov\n\nContract Type. \nFirm-Fixed Priced Contract\n\nEvaluation Factors.\nRequired Features\nPrice\nAuthorization Letter to Distribute\nDelivery Lead Times\n\n\n\nSalient Characteristics \n\nDefinition of salient Characteristics: Those qualities of an item(s) that are essential to ensure that the intended use of the item can be satisfactorily realized.\nCommon Nomenclature (Commercial Description-Please Add Brand Name or Equal to) of Equipment or Supply:   ____Brand name or Equal to The PTeye Parathyroid Detection System _________________\n\nWhat is the country of manufacture (if multiple items, we need multiple countries where the items are made_____Country of Manufacture: United States (USA)_____\n\n\nIs Brand name or Equal to Acceptable if meeting the Salient characteristics needs: Yes _X_ No____\n\nIs a Specific type of material needed: Yes_______ No __X_____________\n\nDescribe What you want the equipment/supply to do (Principal Operation) \nThe requested equipment must be a Dye-FreeÂ intraoperativeÂ ,Â probe basedÂ technology for identification of parathyroid tissue.Â Â Identification of the tissue must use near-infrared (NIR)Â autofluorescence for tissue identification. \n\nEquipment/Supply/Instrument\nDimensions (what is the space requirement for the product?): N/A \nHeight Minimum ___to Maximum Bottom__ \nWidth Minimum __ to Maximum Bottom__\nDepth Minimum __to Maximum Bottom__\nWeight Minimum _to Maximum ______\n\nDisplay/Monitor/Screen:\nDisplay that indicates if the laser is on\nDisplays visual feedback when in contact with tissue  \n\nSoftware Required/associated with this purchase?\nNo\nEnvironmental Considerations: Yes __X_No______\nHumidity control range from 30 % to 90 % non-condensing\nHeating/Cooling range from +10 Â°C to +30 Â°C\n\n\n\nWorking Volume/ Product Performance/Additional requirements: \nMustÂ have a non-ionizing laser with aÂ NIR atÂ noÂ higher thanÂ 785nmÂ \nMust generate bothÂ visual andÂ audibleÂ indicationÂ whenÂ detecting parathyroid tissueÂ Â \n\nAccessories/Consumables: Yes __X__No__\nIf yes what? ____Must be compatible with single use probes\n\nWarranty and Parts/Service Requirements:\nMinimum Warranty Months/Years______1 year minimum___________________________________\nParts/Service/Support options: ________1 year minimum ___________________________________\n\n\nAdditional instructions/Needs/Specifications:\nMust use near-infrared (NIR) autofluorescence  \nMust have a non-ionizing laser with a NIR at no higher than 785nm \nMust be FDA approved\nMust allow in-vivo and ex-vivo evaluation of parathyroid tissue \nMust generate both visual and audible indication when detecting parathyroid tissue  \nMust use single use probes\n\nOther pertinent information that describes the item, material or service needed:\n_______N/A______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________\n\nIf this is replacement equipment, original equipment, original manufacturer, and manufacturer part number if known:\n\n PTeye  parathyroid detection system, manufactured by Medtronic","origin":"detail"},"contacts":[{"name":"Dylan Gore","role":"primary","email":"Dylan.Gore@va.gov","phone":"202-382-2807","title":"Contract Specialist"}],"place_of_performance":{"zip":"20422","city":{"name":"Washington"},"state":{"name":"DC"},"street":"Department of Veterans Affairs Washington DC VA Medical Center","street2":"50 Irving Street NW"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"0c67594004234ae99d55059af1cc728d","name":"36C24526Q0454_1.docx","kind":"file","mime_type":".docx","size_bytes":30914,"posted_at":"2026-05-04T15:25:35.897Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0c67594004234ae99d55059af1cc728d/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":16,"indexable":false}