{"canonical":"https://sealedbidder.com/opportunities/36c24526q0426","key":"36C24526Q0426","url":"https://sealedbidder.com/opportunities/36c24526q0426","title":"J012--Fire Door PM Inspection-Repairs Sources Sought Notice 5 Year Service Contract Baltimore/Loch Raven VA Medical Centers","solicitation_number":"36C24526Q0426","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-17T15:00:00Z","first_posted":"2026-04-02","last_posted":"2026-04-02","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J012","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":"VETERANS FIRE AND LIFE SAFETY CORPORATION","award_amount":null,"publications":[{"notice_id":"70bed7db513744c2bc7475f4e46a6f22","title":"J012--Fire Door PM Inspection-Repairs Sources Sought Notice 5 Year Service Contract Baltimore/Loch Raven VA Medical Centers","solicitation_number":"36C24526Q0426","notice_type":"r","base_type":"r","posted":"2026-04-02","posted_at":"2026-04-02T16:12:35.045Z","due_at":"2026-04-17T15:00:00Z","due_date":"2026-04-17","cancelled":false,"archived":true,"archive_date":"2026-06-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/70bed7db513744c2bc7475f4e46a6f22/view","enriched":true,"history":[{"index":3,"title":"J012--Fire Door PM Inspection-Repairs Sources Sought Notice 5 Year Service Contract Baltimore/Loch Raven VA Medical Centers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T16:12:35.045Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"70bed7db513744c2bc7475f4e46a6f22","solicitation_number":"36C24526Q0426"}]}],"latest_notice_id":"70bed7db513744c2bc7475f4e46a6f22","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-04-02","posted_at":"2026-04-02T16:12:35.045Z","created_at":"2026-04-02T16:12:32.829Z","modified_at":"2026-06-17T03:55:47.260Z","response_deadline":{"raw":"2026-04-17T11:00:00-04:00","utc":"2026-04-17T15:00:00Z","date":"2026-04-17","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/70bed7db513744c2bc7475f4e46a6f22/view"},"naics":{"codes":["561210"],"primary":"561210"},"title":"J012--Fire Door PM Inspection-Repairs Sources Sought Notice 5 Year Service Contract Baltimore/Loch Raven VA Medical Centers","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"J012--Fire Door PM Inspection-Repairs Sources Sought Notice 5 Year Service Contract Baltimore/Loch Raven VA Medical Centers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T16:12:35.045Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"70bed7db513744c2bc7475f4e46a6f22","solicitation_number":"36C24526Q0426"}],"contacts":[{"name":"William Chris Galletta","role":"primary","email":"William.Galletta@va.gov","phone":"410-637-1506","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"70bed7db513744c2bc7475f4e46a6f22","lineage_id":"70bed7db513744c2bc7475f4e46a6f22","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T23:04:13.690372242Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3f496e4a646ae9e790b6ec94234d4428240a107ed3e2bc9676c3c2279e7d832b","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T23:04:13.690372242Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven and Baltimore  VA Medical Centers.\n\n\nPlease respond to this RFI/Sources Sought 36C24526Q0426 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, \nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of \nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include \napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these \nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the \nperformance requirements while complying with applicable limitations in \nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Friday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov \n\n\nREFERENCE: VA Maryland Health Care System, VA2237 #. 512-26-3-641-0148\n\n\nPURPOSE: Contractor shall provide all labor, materials, equipment, and transportation to inspect approximately 375 Fire and Smoke Barrier Doors at the(Baltimore VA Medical Center 10 N. Greene St and Loch Raven 3900 Loch Raven Blvd) facilities. The contractor must deliver a comprehensive report detailing each door's ID, location, condition, maintenance performed, inspector details, and an itemized breakdown of labor, parts, and warranty information. Upon completion of inspections and minor repairs the contractor shall test all functions in the present of VA staff to assure proper safety operations of all fire doors. This will include a detailed description of work performed, any deficiencies the contractor is unable to repair on site, and an itemized breakdown for parts, material and warranty information. \n  \n GOVERNMENT REQUIREMENT:  \n\n\nNo open holes or breaks exist in surfaces of either the door or framing. \nExamine doors, hinges, hardware, frame, and noncombustible thresholds are secured, aligned, and in proper working condition with no visible signs of damage. \nInspect gasket and edge seals, where required, to verify their presence and integrity.\nEnsuring the active door completely closes when operated from the fully open position.\nCheck door clearances at the door edge to the frame, on the pull side of the door, which shall not exceed clearances listed in (4.8.4 and 6.3.1).\nThe Latching hardware will operate and secure the door when it is in the closed position.\nAny Auxiliary hardware items that prohibit or interfere with operation are not installed on the door or frame and no parts are missing or broken.\nThere will be no open holes or breaks in surfaces of either the door or frame.\nGlazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped\nThe clearances between the door and the frame will be 1/8  +/- 1/16  and the meeting edges of pairs of doors shall be 1/8  +/- for steel doors.\nThe clearances between the door and the frame shall not exceed 1/8  and the clearances at the meeting doors edges of pairs of doors shall not exceed 1/8  for wood doors. \nIf a coordinator is installed, the inactive leaf closes before active leaf.  \nNo field modifications to the door assembly have been performed that void the label. \nProvides a Life Safety drawing which will identify the location and placement of identification stickers on each door.\nInspect all Doors in the Customer s facility or otherwise identify  Compliant  and  Non-Compliant  Doors, as determined by the LSS  Inspector(s). The Guidelines for Door Compliance will be based on The National Fire Protection Association s (NFPA) Code  2010 NFPA 80, Standard for Fire Doors and Other Opening Protectives  (the  NPFA Code ) Section.\nEnsure that doors have an average closing speed of not less than 6 in./sec (152 mm/sec) or more than 24 in./sec (610 mm/sec \n\n\n\n\n\n\n\n  STANDARDS:  \n\nAny work the Contractor is required to accomplish due to unsatisfactory performance or nonperformance in accordance with the stated quality and level of effort specified in the contract.  Rework is performed at no additional cost to the Government. Base plus 4 option years contract.\nFollow all Infection Control Risk Assessment (ICRA) guidelines for dust control during all construction work.  A construction dust  Risk Assessment  will be conducted by the Medical Center s Infection Control Nurse.  Temporary  dust  barriers may be installed based on this assessment.  Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment.\nFollow Interim Life Safety Measures. Any series of Operational Actions taken to temporarily reduce hazards posed by Life Safety deficiencies which have been created by demolition, renovation, or construction works, and which are to remain in place and in effect for duration of Contract work.  Provide interim life safety measures (ILSM) where fire protection, fire suppression or smoke/fire partitions will be shut down or rendered ineffective during construction.  Coordinate with VA safety office through VA COR. The ILSM must be always posted outside the work area.\nAll equipment and materials shall be approved prior to being brought on job site. \n\nAlthough normal work hours are Monday through Friday 8:00 a.m. to 4:30 p.m., for critical areas that require shutdowns, work shall be completed on normal weekday after hours. Contractor shall make prior arrangements with the COR to coordinate shut-down periods.  Also, contractors must decide for sub-contractors to work in secure areas. VA will not grant access to sub-contractors; it is the responsibility of the contractor.\nContractor must obtain a burn permit from VA Safety Office prior to any welding, soldering work and burning.\nAll employees of general contractors and subcontractors shall comply with VA security management program and obtain permission of the VA police. \nThe work is in a professional environment; employees must conduct themselves accordingly.  Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site.  Employee's dress code shall consist of normal work uniform.  Shirts must be always worn.\nContractor shall provide general cleaning up to construction area daily to the satisfaction of the VA Project Manager. \nHospital smoking policy (NO SMOKING IN THE BUILDING), smoking must be done in approved smoke shelters or at least 35 feet from any building.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS will be enforced.  Contractor must have 30-hour OSHA Construction Safety course.\nStart up, test, check and adjust all new replacements in the presence of VA COR.\nSlats, end-locks, bottom bar, guide assembly, curtain entry, hood, and flame baffle are correctly installed and intact for rolling steel fire doors.\nMounting and assembly bolts are intact and secure. \n \n\n\n\n\n\nPERIOD OF PERFORMANCE: The period of performance will be for a twelve-month period beginning from the month that the contract is awarded and run for twelve consecutive months after, consisting of one (1) year. Then continue the anniversary date for each of the option year. This contract will cross over fiscal years since it will be awarded in the middle of the fiscal year. The contractor shall perform one (1) inspection per year and make minor repairs within that year. \n\nVA POINT OF CONTACT:   Dudley Brown Maintenance Operation Supervisor. 410-605-7000 Ext. 56040\n\nCOMPETENCY OF PERSONNEL SERVICING EQUIPMENT:\n\na.   The Field Service Engineer (FSE) MUST be authorized by the contractor to perform maintenance services.  The Contractor shall provide written assurance of the competency of their personnel and a list of the credentials of approved FSEs for each model of equipment serviced by the contractor at the VA Maryland Health Care System (VAMHCS) and the Washington, DC Medical Center for CO review and approval.  The Contractor must provide authenticated factory training certificates or credentials (or acceptable substitutes as approved by the COR) for any personnel who are servicing or installing any VAMHCS Baltimore and Loch Raven equipment.  VAMHCS specifically reserves the right to reject any of the contractor s personnel and refuse permission to work on VA equipment.\n\nThe Contractor shall furnish and replace all equipment replacement parts. The Contractor shall have ready access to all equipment parts, including unique and hard to find replacement parts, to minimize downtime.\n\n\nOnly new standard parts (manufactured by the maker of the equipment or equal thereto) shall be furnished by the Contractor.  Rebuild parts, used parts, or those removed from the same model of equipment shall NOT be installed without prior approval of the COR.  All parts supplied by the Contractor shall be of current manufacture and have complete versatility with the presently installed equipment.  All parts shall perform identically to the original equipment manufacturers specifications.","text":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven and Baltimore VA Medical Centers.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0426 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of\nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these\nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the\nperformance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Friday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov\n\nREFERENCE: VA Maryland Health Care System, VA2237 #. 512-26-3-641-0148\n\nPURPOSE: Contractor shall provide all labor, materials, equipment, and transportation to inspect approximately 375 Fire and Smoke Barrier Doors at the(Baltimore VA Medical Center 10 N. Greene St and Loch Raven 3900 Loch Raven Blvd) facilities. The contractor must deliver a comprehensive report detailing each door's ID, location, condition, maintenance performed, inspector details, and an itemized breakdown of labor, parts, and warranty information. Upon completion of inspections and minor repairs the contractor shall test all functions in the present of VA staff to assure proper safety operations of all fire doors. This will include a detailed description of work performed, any deficiencies the contractor is unable to repair on site, and an itemized breakdown for parts, material and warranty information.\n\nGOVERNMENT REQUIREMENT:\n\nNo open holes or breaks exist in surfaces of either the door or framing.\nExamine doors, hinges, hardware, frame, and noncombustible thresholds are secured, aligned, and in proper working condition with no visible signs of damage.\nInspect gasket and edge seals, where required, to verify their presence and integrity.\nEnsuring the active door completely closes when operated from the fully open position.\nCheck door clearances at the door edge to the frame, on the pull side of the door, which shall not exceed clearances listed in (4.8.4 and 6.3.1).\nThe Latching hardware will operate and secure the door when it is in the closed position.\nAny Auxiliary hardware items that prohibit or interfere with operation are not installed on the door or frame and no parts are missing or broken.\nThere will be no open holes or breaks in surfaces of either the door or frame.\nGlazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped\nThe clearances between the door and the frame will be 1/8 +/- 1/16 and the meeting edges of pairs of doors shall be 1/8 +/- for steel doors.\nThe clearances between the door and the frame shall not exceed 1/8 and the clearances at the meeting doors edges of pairs of doors shall not exceed 1/8 for wood doors.\nIf a coordinator is installed, the inactive leaf closes before active leaf.\nNo field modifications to the door assembly have been performed that void the label.\nProvides a Life Safety drawing which will identify the location and placement of identification stickers on each door.\nInspect all Doors in the Customer s facility or otherwise identify Compliant and Non-Compliant Doors, as determined by the LSS Inspector(s). The Guidelines for Door Compliance will be based on The National Fire Protection Association s (NFPA) Code 2010 NFPA 80, Standard for Fire Doors and Other Opening Protectives (the NPFA Code ) Section.\nEnsure that doors have an average closing speed of not less than 6 in./sec (152 mm/sec) or more than 24 in./sec (610 mm/sec\n\nSTANDARDS:\n\nAny work the Contractor is required to accomplish due to unsatisfactory performance or nonperformance in accordance with the stated quality and level of effort specified in the contract. Rework is performed at no additional cost to the Government. Base plus 4 option years contract.\nFollow all Infection Control Risk Assessment (ICRA) guidelines for dust control during all construction work. A construction dust Risk Assessment will be conducted by the Medical Center s Infection Control Nurse. Temporary dust barriers may be installed based on this assessment. Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment.\nFollow Interim Life Safety Measures. Any series of Operational Actions taken to temporarily reduce hazards posed by Life Safety deficiencies which have been created by demolition, renovation, or construction works, and which are to remain in place and in effect for duration of Contract work. Provide interim life safety measures (ILSM) where fire protection, fire suppression or smoke/fire partitions will be shut down or rendered ineffective during construction. Coordinate with VA safety office through VA COR. The ILSM must be always posted outside the work area.\nAll equipment and materials shall be approved prior to being brought on job site.\n\nAlthough normal work hours are Monday through Friday 8:00 a.m. to 4:30 p.m., for critical areas that require shutdowns, work shall be completed on normal weekday after hours. Contractor shall make prior arrangements with the COR to coordinate shut-down periods. Also, contractors must decide for sub-contractors to work in secure areas. VA will not grant access to sub-contractors; it is the responsibility of the contractor.\nContractor must obtain a burn permit from VA Safety Office prior to any welding, soldering work and burning.\nAll employees of general contractors and subcontractors shall comply with VA security management program and obtain permission of the VA police.\nThe work is in a professional environment; employees must conduct themselves accordingly. Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site. Employee's dress code shall consist of normal work uniform. Shirts must be always worn.\nContractor shall provide general cleaning up to construction area daily to the satisfaction of the VA Project Manager.\nHospital smoking policy (NO SMOKING IN THE BUILDING), smoking must be done in approved smoke shelters or at least 35 feet from any building.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS will be enforced. Contractor must have 30-hour OSHA Construction Safety course.\nStart up, test, check and adjust all new replacements in the presence of VA COR.\nSlats, end-locks, bottom bar, guide assembly, curtain entry, hood, and flame baffle are correctly installed and intact for rolling steel fire doors.\nMounting and assembly bolts are intact and secure.\n\nPERIOD OF PERFORMANCE: The period of performance will be for a twelve-month period beginning from the month that the contract is awarded and run for twelve consecutive months after, consisting of one (1) year. Then continue the anniversary date for each of the option year. This contract will cross over fiscal years since it will be awarded in the middle of the fiscal year. The contractor shall perform one (1) inspection per year and make minor repairs within that year.\n\nVA POINT OF CONTACT: Dudley Brown Maintenance Operation Supervisor. 410-605-7000 Ext. 56040\n\nCOMPETENCY OF PERSONNEL SERVICING EQUIPMENT:\n\na. The Field Service Engineer (FSE) MUST be authorized by the contractor to perform maintenance services. The Contractor shall provide written assurance of the competency of their personnel and a list of the credentials of approved FSEs for each model of equipment serviced by the contractor at the VA Maryland Health Care System (VAMHCS) and the Washington, DC Medical Center for CO review and approval. The Contractor must provide authenticated factory training certificates or credentials (or acceptable substitutes as approved by the COR) for any personnel who are servicing or installing any VAMHCS Baltimore and Loch Raven equipment. VAMHCS specifically reserves the right to reject any of the contractor s personnel and refuse permission to work on VA equipment.\n\nThe Contractor shall furnish and replace all equipment replacement parts. The Contractor shall have ready access to all equipment parts, including unique and hard to find replacement parts, to minimize downtime.\n\nOnly new standard parts (manufactured by the maker of the equipment or equal thereto) shall be furnished by the Contractor. Rebuild parts, used parts, or those removed from the same model of equipment shall NOT be installed without prior approval of the COR. All parts supplied by the Contractor shall be of current manufacture and have complete versatility with the presently installed equipment. All parts shall perform identically to the original equipment manufacturers specifications.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0426","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs Baltimore Loch Raven VAMCs","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N Greene St"},"product_service_code":"J012"}],"due_at":"2026-04-17T15:00:00Z","due_date":"2026-04-17","closes_at":"2026-04-17T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"L3CVUQMB3NC9","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-10-08T23:52:34.212691Z","principal_notice_id":"70bed7db513744c2bc7475f4e46a6f22","description":{"text":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven and Baltimore VA Medical Centers.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0426 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of\nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these\nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the\nperformance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Friday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov\n\nREFERENCE: VA Maryland Health Care System, VA2237 #. 512-26-3-641-0148\n\nPURPOSE: Contractor shall provide all labor, materials, equipment, and transportation to inspect approximately 375 Fire and Smoke Barrier Doors at the(Baltimore VA Medical Center 10 N. Greene St and Loch Raven 3900 Loch Raven Blvd) facilities. The contractor must deliver a comprehensive report detailing each door's ID, location, condition, maintenance performed, inspector details, and an itemized breakdown of labor, parts, and warranty information. Upon completion of inspections and minor repairs the contractor shall test all functions in the present of VA staff to assure proper safety operations of all fire doors. This will include a detailed description of work performed, any deficiencies the contractor is unable to repair on site, and an itemized breakdown for parts, material and warranty information.\n\nGOVERNMENT REQUIREMENT:\n\nNo open holes or breaks exist in surfaces of either the door or framing.\nExamine doors, hinges, hardware, frame, and noncombustible thresholds are secured, aligned, and in proper working condition with no visible signs of damage.\nInspect gasket and edge seals, where required, to verify their presence and integrity.\nEnsuring the active door completely closes when operated from the fully open position.\nCheck door clearances at the door edge to the frame, on the pull side of the door, which shall not exceed clearances listed in (4.8.4 and 6.3.1).\nThe Latching hardware will operate and secure the door when it is in the closed position.\nAny Auxiliary hardware items that prohibit or interfere with operation are not installed on the door or frame and no parts are missing or broken.\nThere will be no open holes or breaks in surfaces of either the door or frame.\nGlazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped\nThe clearances between the door and the frame will be 1/8 +/- 1/16 and the meeting edges of pairs of doors shall be 1/8 +/- for steel doors.\nThe clearances between the door and the frame shall not exceed 1/8 and the clearances at the meeting doors edges of pairs of doors shall not exceed 1/8 for wood doors.\nIf a coordinator is installed, the inactive leaf closes before active leaf.\nNo field modifications to the door assembly have been performed that void the label.\nProvides a Life Safety drawing which will identify the location and placement of identification stickers on each door.\nInspect all Doors in the Customer s facility or otherwise identify Compliant and Non-Compliant Doors, as determined by the LSS Inspector(s). The Guidelines for Door Compliance will be based on The National Fire Protection Association s (NFPA) Code 2010 NFPA 80, Standard for Fire Doors and Other Opening Protectives (the NPFA Code ) Section.\nEnsure that doors have an average closing speed of not less than 6 in./sec (152 mm/sec) or more than 24 in./sec (610 mm/sec\n\nSTANDARDS:\n\nAny work the Contractor is required to accomplish due to unsatisfactory performance or nonperformance in accordance with the stated quality and level of effort specified in the contract. Rework is performed at no additional cost to the Government. Base plus 4 option years contract.\nFollow all Infection Control Risk Assessment (ICRA) guidelines for dust control during all construction work. A construction dust Risk Assessment will be conducted by the Medical Center s Infection Control Nurse. Temporary dust barriers may be installed based on this assessment. Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment.\nFollow Interim Life Safety Measures. Any series of Operational Actions taken to temporarily reduce hazards posed by Life Safety deficiencies which have been created by demolition, renovation, or construction works, and which are to remain in place and in effect for duration of Contract work. Provide interim life safety measures (ILSM) where fire protection, fire suppression or smoke/fire partitions will be shut down or rendered ineffective during construction. Coordinate with VA safety office through VA COR. The ILSM must be always posted outside the work area.\nAll equipment and materials shall be approved prior to being brought on job site.\n\nAlthough normal work hours are Monday through Friday 8:00 a.m. to 4:30 p.m., for critical areas that require shutdowns, work shall be completed on normal weekday after hours. Contractor shall make prior arrangements with the COR to coordinate shut-down periods. Also, contractors must decide for sub-contractors to work in secure areas. VA will not grant access to sub-contractors; it is the responsibility of the contractor.\nContractor must obtain a burn permit from VA Safety Office prior to any welding, soldering work and burning.\nAll employees of general contractors and subcontractors shall comply with VA security management program and obtain permission of the VA police.\nThe work is in a professional environment; employees must conduct themselves accordingly. Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site. Employee's dress code shall consist of normal work uniform. Shirts must be always worn.\nContractor shall provide general cleaning up to construction area daily to the satisfaction of the VA Project Manager.\nHospital smoking policy (NO SMOKING IN THE BUILDING), smoking must be done in approved smoke shelters or at least 35 feet from any building.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS will be enforced. Contractor must have 30-hour OSHA Construction Safety course.\nStart up, test, check and adjust all new replacements in the presence of VA COR.\nSlats, end-locks, bottom bar, guide assembly, curtain entry, hood, and flame baffle are correctly installed and intact for rolling steel fire doors.\nMounting and assembly bolts are intact and secure.\n\nPERIOD OF PERFORMANCE: The period of performance will be for a twelve-month period beginning from the month that the contract is awarded and run for twelve consecutive months after, consisting of one (1) year. Then continue the anniversary date for each of the option year. This contract will cross over fiscal years since it will be awarded in the middle of the fiscal year. The contractor shall perform one (1) inspection per year and make minor repairs within that year.\n\nVA POINT OF CONTACT: Dudley Brown Maintenance Operation Supervisor. 410-605-7000 Ext. 56040\n\nCOMPETENCY OF PERSONNEL SERVICING EQUIPMENT:\n\na. The Field Service Engineer (FSE) MUST be authorized by the contractor to perform maintenance services. The Contractor shall provide written assurance of the competency of their personnel and a list of the credentials of approved FSEs for each model of equipment serviced by the contractor at the VA Maryland Health Care System (VAMHCS) and the Washington, DC Medical Center for CO review and approval. The Contractor must provide authenticated factory training certificates or credentials (or acceptable substitutes as approved by the COR) for any personnel who are servicing or installing any VAMHCS Baltimore and Loch Raven equipment. VAMHCS specifically reserves the right to reject any of the contractor s personnel and refuse permission to work on VA equipment.\n\nThe Contractor shall furnish and replace all equipment replacement parts. The Contractor shall have ready access to all equipment parts, including unique and hard to find replacement parts, to minimize downtime.\n\nOnly new standard parts (manufactured by the maker of the equipment or equal thereto) shall be furnished by the Contractor. Rebuild parts, used parts, or those removed from the same model of equipment shall NOT be installed without prior approval of the COR. All parts supplied by the Contractor shall be of current manufacture and have complete versatility with the presently installed equipment. All parts shall perform identically to the original equipment manufacturers specifications.","html":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven and Baltimore  VA Medical Centers.\n\n\nPlease respond to this RFI/Sources Sought 36C24526Q0426 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, \nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of \nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include \napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these \nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the \nperformance requirements while complying with applicable limitations in \nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Friday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov \n\n\nREFERENCE: VA Maryland Health Care System, VA2237 #. 512-26-3-641-0148\n\n\nPURPOSE: Contractor shall provide all labor, materials, equipment, and transportation to inspect approximately 375 Fire and Smoke Barrier Doors at the(Baltimore VA Medical Center 10 N. Greene St and Loch Raven 3900 Loch Raven Blvd) facilities. The contractor must deliver a comprehensive report detailing each door's ID, location, condition, maintenance performed, inspector details, and an itemized breakdown of labor, parts, and warranty information. Upon completion of inspections and minor repairs the contractor shall test all functions in the present of VA staff to assure proper safety operations of all fire doors. This will include a detailed description of work performed, any deficiencies the contractor is unable to repair on site, and an itemized breakdown for parts, material and warranty information. \n  \n GOVERNMENT REQUIREMENT:  \n\n\nNo open holes or breaks exist in surfaces of either the door or framing. \nExamine doors, hinges, hardware, frame, and noncombustible thresholds are secured, aligned, and in proper working condition with no visible signs of damage. \nInspect gasket and edge seals, where required, to verify their presence and integrity.\nEnsuring the active door completely closes when operated from the fully open position.\nCheck door clearances at the door edge to the frame, on the pull side of the door, which shall not exceed clearances listed in (4.8.4 and 6.3.1).\nThe Latching hardware will operate and secure the door when it is in the closed position.\nAny Auxiliary hardware items that prohibit or interfere with operation are not installed on the door or frame and no parts are missing or broken.\nThere will be no open holes or breaks in surfaces of either the door or frame.\nGlazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped\nThe clearances between the door and the frame will be 1/8  +/- 1/16  and the meeting edges of pairs of doors shall be 1/8  +/- for steel doors.\nThe clearances between the door and the frame shall not exceed 1/8  and the clearances at the meeting doors edges of pairs of doors shall not exceed 1/8  for wood doors. \nIf a coordinator is installed, the inactive leaf closes before active leaf.  \nNo field modifications to the door assembly have been performed that void the label. \nProvides a Life Safety drawing which will identify the location and placement of identification stickers on each door.\nInspect all Doors in the Customer s facility or otherwise identify  Compliant  and  Non-Compliant  Doors, as determined by the LSS  Inspector(s). The Guidelines for Door Compliance will be based on The National Fire Protection Association s (NFPA) Code  2010 NFPA 80, Standard for Fire Doors and Other Opening Protectives  (the  NPFA Code ) Section.\nEnsure that doors have an average closing speed of not less than 6 in./sec (152 mm/sec) or more than 24 in./sec (610 mm/sec \n\n\n\n\n\n\n\n  STANDARDS:  \n\nAny work the Contractor is required to accomplish due to unsatisfactory performance or nonperformance in accordance with the stated quality and level of effort specified in the contract.  Rework is performed at no additional cost to the Government. Base plus 4 option years contract.\nFollow all Infection Control Risk Assessment (ICRA) guidelines for dust control during all construction work.  A construction dust  Risk Assessment  will be conducted by the Medical Center s Infection Control Nurse.  Temporary  dust  barriers may be installed based on this assessment.  Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment.\nFollow Interim Life Safety Measures. Any series of Operational Actions taken to temporarily reduce hazards posed by Life Safety deficiencies which have been created by demolition, renovation, or construction works, and which are to remain in place and in effect for duration of Contract work.  Provide interim life safety measures (ILSM) where fire protection, fire suppression or smoke/fire partitions will be shut down or rendered ineffective during construction.  Coordinate with VA safety office through VA COR. The ILSM must be always posted outside the work area.\nAll equipment and materials shall be approved prior to being brought on job site. \n\nAlthough normal work hours are Monday through Friday 8:00 a.m. to 4:30 p.m., for critical areas that require shutdowns, work shall be completed on normal weekday after hours. Contractor shall make prior arrangements with the COR to coordinate shut-down periods.  Also, contractors must decide for sub-contractors to work in secure areas. VA will not grant access to sub-contractors; it is the responsibility of the contractor.\nContractor must obtain a burn permit from VA Safety Office prior to any welding, soldering work and burning.\nAll employees of general contractors and subcontractors shall comply with VA security management program and obtain permission of the VA police. \nThe work is in a professional environment; employees must conduct themselves accordingly.  Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site.  Employee's dress code shall consist of normal work uniform.  Shirts must be always worn.\nContractor shall provide general cleaning up to construction area daily to the satisfaction of the VA Project Manager. \nHospital smoking policy (NO SMOKING IN THE BUILDING), smoking must be done in approved smoke shelters or at least 35 feet from any building.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS will be enforced.  Contractor must have 30-hour OSHA Construction Safety course.\nStart up, test, check and adjust all new replacements in the presence of VA COR.\nSlats, end-locks, bottom bar, guide assembly, curtain entry, hood, and flame baffle are correctly installed and intact for rolling steel fire doors.\nMounting and assembly bolts are intact and secure. \n \n\n\n\n\n\nPERIOD OF PERFORMANCE: The period of performance will be for a twelve-month period beginning from the month that the contract is awarded and run for twelve consecutive months after, consisting of one (1) year. Then continue the anniversary date for each of the option year. This contract will cross over fiscal years since it will be awarded in the middle of the fiscal year. The contractor shall perform one (1) inspection per year and make minor repairs within that year. \n\nVA POINT OF CONTACT:   Dudley Brown Maintenance Operation Supervisor. 410-605-7000 Ext. 56040\n\nCOMPETENCY OF PERSONNEL SERVICING EQUIPMENT:\n\na.   The Field Service Engineer (FSE) MUST be authorized by the contractor to perform maintenance services.  The Contractor shall provide written assurance of the competency of their personnel and a list of the credentials of approved FSEs for each model of equipment serviced by the contractor at the VA Maryland Health Care System (VAMHCS) and the Washington, DC Medical Center for CO review and approval.  The Contractor must provide authenticated factory training certificates or credentials (or acceptable substitutes as approved by the COR) for any personnel who are servicing or installing any VAMHCS Baltimore and Loch Raven equipment.  VAMHCS specifically reserves the right to reject any of the contractor s personnel and refuse permission to work on VA equipment.\n\nThe Contractor shall furnish and replace all equipment replacement parts. The Contractor shall have ready access to all equipment parts, including unique and hard to find replacement parts, to minimize downtime.\n\n\nOnly new standard parts (manufactured by the maker of the equipment or equal thereto) shall be furnished by the Contractor.  Rebuild parts, used parts, or those removed from the same model of equipment shall NOT be installed without prior approval of the COR.  All parts supplied by the Contractor shall be of current manufacture and have complete versatility with the presently installed equipment.  All parts shall perform identically to the original equipment manufacturers specifications.","origin":"detail"},"contacts":[{"name":"William Chris Galletta","role":"primary","email":"William.Galletta@va.gov","phone":"410-637-1506","title":"Contracting Officer"}],"place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs Baltimore Loch Raven VAMCs","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N Greene St"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["561210"],"award":{"awardee":{}},"attachments":[{"resource_id":"0a3035b11641430c851e820651341624","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-04-02T16:12:35.045Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/maryland-health-care/locations/baltimore-","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24526P0398_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24526P0398_3600_-NONE-_-NONE-/","piid":"36C24526P0398","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"L3CVUQMB3NC9","recipient_name":"VETERANS FIRE AND LIFE SAFETY CORPORATION","recipient_uei":"L3CVUQMB3NC9","recipient_cage":"56HQ8","recipient_city":"SAINT PETERS","recipient_state":"MO","sub_name":"Department of Veterans Affairs","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","office_key":"o-36C245","first_action_date":"2026-08-14","last_action_date":"2026-10-22","actions":2,"obligated":"18000.00","current_total_value":"18000.00","potential_total_value":"90000.00","naics":"561210","psc":"J054","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":2,"description":"FIRE DOOR PMS","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24526Q0426 equals the FPDS solicitation identifier","same awarding office 36C245"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24527Q0058","latest_notice_id":"740a0ce07bb64f898a0cbfb567da2a5c","title":"F014--TREE REMOVAL VAMC MARTINSBURG","solicitation_number":"36C24527Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561730","psc":"F014","set_aside":null,"state":"WV","county":"54003","county_name":"Berkeley County","city":"5452060","city_name":"Martinsburg","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"80NSSC27949318Q","latest_notice_id":"0d066648ad374f69b192a8c73bf3f559","title":"Haskel Booster & Components","solicitation_number":"80NSSC27949318Q","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"561210","psc":"4940","set_aside":"SBA","state":"MS","county":"28045","county_name":"Hancock County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"75H70727Q00003","latest_notice_id":"7390db3f3afa46d3a8424450ec68c329","title":"Fire Door Inspection, Assessment, and Maintenance at the Albuquerque Area IHS Healthcare Facilities","solicitation_number":"75H70727Q00003","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-11-13","notices":5,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H707","office_name":"ALBUQUERQUE AREA INDIAN HEALTH SVC","naics":"561210","psc":"J012","set_aside":"SBA","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3502000","city_name":"Albuquerque","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-21T06:18:57.723715Z"}],"similar_open_total":39,"indexable":false}