{"canonical":"https://sealedbidder.com/opportunities/36c24526q0377","key":"36C24526Q0377","url":"https://sealedbidder.com/opportunities/36c24526q0377","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-06T16:00:00Z","first_posted":"2026-03-23","last_posted":"2026-04-01","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"333914","psc":"6680","set_aside":"SBA","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"LOCH RAVEN MD VA MEDICAL CENTER 3901 LOCH RAVEN BLVD BALTIMORE, MD. 21218","place_county":"24005","place_county_name":"Baltimore County","place_city":"2459425","place_city_name":"Owings Mills","winner":"DATANET ENGINEERING, INC.","award_amount":null,"publications":[{"notice_id":"d04840fa9d1e41218c8c0a2a4e7ae937","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","base_type":"k","posted":"2026-03-23","posted_at":"2026-03-23T17:50:50.103Z","due_at":"2026-03-30T16:00:00Z","due_date":"2026-03-30","cancelled":false,"archived":true,"archive_date":"2026-04-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d04840fa9d1e41218c8c0a2a4e7ae937/view","enriched":true,"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}]},{"notice_id":"a75105d801754e15ab69e818c757bdc6","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","base_type":"k","posted":"2026-03-25","posted_at":"2026-03-25T13:59:04.521Z","due_at":"2026-03-30T16:00:00Z","due_date":"2026-03-30","cancelled":false,"archived":true,"archive_date":"2026-04-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a75105d801754e15ab69e818c757bdc6/view","enriched":true,"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}]},{"notice_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","base_type":"k","posted":"2026-03-26","posted_at":"2026-03-26T20:22:40.584Z","due_at":"2026-04-06T16:00:00Z","due_date":"2026-04-06","cancelled":false,"archived":true,"archive_date":"2026-04-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1ad41543b2d4420ab6fe1dc14b1bb21d/view","enriched":true,"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}]},{"notice_id":"c68a33cd4e244aa3a2344a88cb27fdf5","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","base_type":"k","posted":"2026-03-31","posted_at":"2026-03-31T12:35:10.940Z","due_at":"2026-04-06T16:00:00Z","due_date":"2026-04-06","cancelled":false,"archived":true,"archive_date":"2026-04-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c68a33cd4e244aa3a2344a88cb27fdf5/view","enriched":true,"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}]},{"notice_id":"ba0e4bfdb51e4fd69ff890acd65c8239","title":"6680--Loch Raven Boiler Fuel Reserve Tank","solicitation_number":"36C24526Q0377","notice_type":"k","base_type":"k","posted":"2026-04-01","posted_at":"2026-04-01T20:14:53.472Z","due_at":"2026-04-06T16:00:00Z","due_date":"2026-04-06","cancelled":false,"archived":true,"archive_date":"2026-04-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ba0e4bfdb51e4fd69ff890acd65c8239/view","enriched":true,"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}]}],"latest_notice_id":"ba0e4bfdb51e4fd69ff890acd65c8239","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-23","posted_at":"2026-03-23T17:50:50.103Z","created_at":"2026-03-23T17:50:45.629Z","modified_at":"2026-04-17T03:55:45.415Z","response_deadline":{"raw":"2026-03-30T12:00:00-04:00","utc":"2026-03-30T16:00:00Z","date":"2026-03-30","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d04840fa9d1e41218c8c0a2a4e7ae937/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"6680--Loch Raven Boiler Fuel Reserve Tank","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-09","archive_type":"auto_custom"},"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}],"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d04840fa9d1e41218c8c0a2a4e7ae937","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d04840fa9d1e41218c8c0a2a4e7ae937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T03:27:51.498006777Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"cde4dc08d080f7d503a8c3aec7a23dbe3e94628a36205c5e1451884e4f1017a2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-10T03:27:51.498006777Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"The purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area.","text":"The purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24526Q0377","place_of_performance":{"street":"Loch Raven MD VA Medical Center 3901 Loch Raven Blvd","country":{"code":"USA","name":"UNITED STATES"},"street2":"Baltimore, MD. 21218"},"product_service_code":"6680"},{"award":{"awardee":{}},"dates":{"posted":"2026-03-25","posted_at":"2026-03-25T13:59:04.521Z","created_at":"2026-03-25T13:59:00.987Z","modified_at":"2026-04-17T03:55:45.415Z","response_deadline":{"raw":"2026-03-30T12:00:00-04:00","utc":"2026-03-30T16:00:00Z","date":"2026-03-30","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a75105d801754e15ab69e818c757bdc6/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"6680--Loch Raven Boiler Fuel Reserve Tank","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-09","archive_type":"auto_custom"},"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}],"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"a75105d801754e15ab69e818c757bdc6","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d04840fa9d1e41218c8c0a2a4e7ae937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T01:55:21.360956070Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"22b9d0f87c14604ad399e065c946184a16d9f2db1005b0488e3e7f6f721ed657","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-10T01:55:21.360956070Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"AMENDMENT TO SOLICITATION  - 36C24526Q0377\n\nAttachment of Loch Raven MD Property for placement location of Boiler Reserve Fuel Tank to be installed.  See the BLUE X next to EMERGENCY POWER.\n\nSolicitation will close on Monday, 3/30/26 at 12PM EST.","text":"AMENDMENT TO SOLICITATION - 36C24526Q0377\n\nAttachment of Loch Raven MD Property for placement location of Boiler Reserve Fuel Tank to be installed. See the BLUE X next to EMERGENCY POWER.\n\nSolicitation will close on Monday, 3/30/26 at 12PM EST.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24526Q0377","place_of_performance":{"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6680"},{"award":{"awardee":{}},"dates":{"posted":"2026-03-26","posted_at":"2026-03-26T20:22:40.584Z","created_at":"2026-03-26T20:22:39.235Z","modified_at":"2026-04-17T03:55:45.415Z","response_deadline":{"raw":"2026-04-06T12:00:00-04:00","utc":"2026-04-06T16:00:00Z","date":"2026-04-06","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1ad41543b2d4420ab6fe1dc14b1bb21d/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"6680--Loch Raven Boiler Fuel Reserve Tank","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-16","archive_type":"auto_custom"},"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}],"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d04840fa9d1e41218c8c0a2a4e7ae937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T02:49:14.398756371Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"fe1ad95aef51ea5ba505af228b1890b67329a9693cfd7960c3f5d77be0e4c645","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T02:49:14.398756371Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"AMENDMENT ON SOLICITATION   36C24526Q0377\n\nThis amendment is to extend the closing of this solicitation for another week.\n\nThe solicitation will now close on Monday, 4/6/26 at 12PM EST.","text":"AMENDMENT ON SOLICITATION 36C24526Q0377\n\nThis amendment is to extend the closing of this solicitation for another week.\n\nThe solicitation will now close on Monday, 4/6/26 at 12PM EST.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24526Q0377","place_of_performance":{"street":"Loch Raven MD VA Medical Center 3901 Loch Raven Blvd.","country":{"code":"USA","name":"UNITED STATES"},"street2":"Baltimore, MD. 21902"},"product_service_code":"6680"},{"award":{"awardee":{}},"dates":{"posted":"2026-03-31","posted_at":"2026-03-31T12:35:10.940Z","created_at":"2026-03-31T12:35:06.907Z","modified_at":"2026-04-17T03:55:45.415Z","response_deadline":{"raw":"2026-04-06T12:00:00-04:00","utc":"2026-04-06T16:00:00Z","date":"2026-04-06","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c68a33cd4e244aa3a2344a88cb27fdf5/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"6680--Loch Raven Boiler Fuel Reserve Tank","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-16","archive_type":"auto_custom"},"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}],"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"c68a33cd4e244aa3a2344a88cb27fdf5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d04840fa9d1e41218c8c0a2a4e7ae937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T01:23:32.387245780Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"d093f1e96c102f3b059f4f2af4e4c1defea7a912f47486f840abc92851bdedd6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T01:23:32.387245780Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"AMENDMENT TO SOLICITATION   36C24526Q0377\n\nThis amendment is to answer the following questions:\n\nWhat is the distance from the new tank location to the Boiler Room? This distance is approximately 40 feet. Picture attached.\nIs there an existing electrical source near the proposed tank location suitable for powering pumps, leak detection, or monitoring equipment? Yes, the shop recommends G-17 and running a cord to an outlet or tying into one of the panels inside. This will be determined in the field.\nDoes the facility currently hold an oil storage or oil burning operating permit? Yes, the facility does hold an oil storage permit.\nPlease confirm the model number of the existing Veeder Root monitoring system so we can verify compatibility with the new tank installation.            Model: TLS-450 Plus\n\nThe solicitation will be closed on Monday, 4/6/2026 at 12PM EST.","text":"AMENDMENT TO SOLICITATION 36C24526Q0377\n\nThis amendment is to answer the following questions:\n\nWhat is the distance from the new tank location to the Boiler Room? This distance is approximately 40 feet. Picture attached.\nIs there an existing electrical source near the proposed tank location suitable for powering pumps, leak detection, or monitoring equipment? Yes, the shop recommends G-17 and running a cord to an outlet or tying into one of the panels inside. This will be determined in the field.\nDoes the facility currently hold an oil storage or oil burning operating permit? Yes, the facility does hold an oil storage permit.\nPlease confirm the model number of the existing Veeder Root monitoring system so we can verify compatibility with the new tank installation. Model: TLS-450 Plus\n\nThe solicitation will be closed on Monday, 4/6/2026 at 12PM EST.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24526Q0377","place_of_performance":{"street":"Loch Raven MD VA Medical Center 3901 Loch Raven Blvd.","country":{"code":"USA","name":"UNITED STATES"},"street2":"Baltimore, MD. 21218"},"product_service_code":"6680"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-01","posted_at":"2026-04-01T20:14:53.472Z","created_at":"2026-04-01T20:14:50.987Z","modified_at":"2026-04-17T03:55:45.415Z","response_deadline":{"raw":"2026-04-06T12:00:00-04:00","utc":"2026-04-06T16:00:00Z","date":"2026-04-06","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ba0e4bfdb51e4fd69ff890acd65c8239/view"},"naics":{"codes":["333914"],"primary":"333914"},"title":"6680--Loch Raven Boiler Fuel Reserve Tank","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-16","archive_type":"auto_custom"},"history":[{"index":6,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-01T20:14:53.472Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ba0e4bfdb51e4fd69ff890acd65c8239","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":4,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-31T12:35:10.940Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c68a33cd4e244aa3a2344a88cb27fdf5","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":3,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-26T20:22:40.584Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1ad41543b2d4420ab6fe1dc14b1bb21d","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":2,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-25T13:59:04.521Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a75105d801754e15ab69e818c757bdc6","solicitation_number":"36C24526Q0377","parent_opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937"},{"index":1,"title":"6680--Loch Raven Boiler Fuel Reserve Tank","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-23T17:50:50.103Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d04840fa9d1e41218c8c0a2a4e7ae937","solicitation_number":"36C24526Q0377"}],"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ba0e4bfdb51e4fd69ff890acd65c8239","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d04840fa9d1e41218c8c0a2a4e7ae937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T00:37:28.848839834Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"969b97a4b9d6d3aeab258897dbf8dd977eeea2ddfbe50af1ee5face9eed458e3","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T00:37:28.848839834Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"AMENDMENT TO SOLICITATION - 36C24526Q0377\n\nIt is being added to the STATEMENT OF WORK\n**The contractor must provide a 1  thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2  radially from the support to distribute the load.**\n\nB.2 STATEMENT OF WORK \nLR Boiler Reserve Fuel Tank \n\nSCOPE OF WORK: \nThe purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST).  The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage. \n\nFuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings. \nSupport the piping properly and connect it to the existing piping outside the building at the sump. \n\nFuel Delivery: The owner will provide a fuel delivery to the tank. \nInstallation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank. \nSecured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access. \n\nIntegration with Existing Monitoring System: \nInstall a refurbished probe with a diesel and water float kit. \nInstall all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code. \nInstall an interstitial sensor in the tank secondary along with all necessary wiring and connections. \nProgram the existing Veeder Root console to monitor the diesel probe and sensor. \nProgram the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank. \n**The contractor must provide a 1  thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2  radially from the support to distribute the load.**\nDELIVERABLES: \n6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components. \nSecure fencing and traffic barriers to protect the tank. \n\nFuel Piping: Installed supply and return piping with necessary and compatible valves and fittings. \nMonitoring System Integration: Refurbished probe with diesel and water float kit. \nInstalled interstitial sensor and all necessary wiring. \nProgrammed Veeder Root console for monitoring and overfill protection. \n\nResponsibilities: \nContractor: Responsible for the delivery and installation of the fuel tank and associated components. \nResponsible for installing the piping, barriers, and fencing. \nResponsible for integrating the tank with the existing Veeder Root monitoring system. \nThe tank will be installed directly on the existing asphalt driveway. \nAll work is to be performed in compliance with relevant regulations and safety standards. \n\nEVALUATION FACTORS: \nVendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.","text":"AMENDMENT TO SOLICITATION - 36C24526Q0377\n\nIt is being added to the STATEMENT OF WORK\n**The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.**\n\nB.2 STATEMENT OF WORK\nLR Boiler Reserve Fuel Tank\n\nSCOPE OF WORK:\nThe purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST). The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage.\n\nFuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings.\nSupport the piping properly and connect it to the existing piping outside the building at the sump.\n\nFuel Delivery: The owner will provide a fuel delivery to the tank.\nInstallation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank.\nSecured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access.\n\nIntegration with Existing Monitoring System:\nInstall a refurbished probe with a diesel and water float kit.\nInstall all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code.\nInstall an interstitial sensor in the tank secondary along with all necessary wiring and connections.\nProgram the existing Veeder Root console to monitor the diesel probe and sensor.\nProgram the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank.\n**The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.**\nDELIVERABLES:\n6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components.\nSecure fencing and traffic barriers to protect the tank.\n\nFuel Piping: Installed supply and return piping with necessary and compatible valves and fittings.\nMonitoring System Integration: Refurbished probe with diesel and water float kit.\nInstalled interstitial sensor and all necessary wiring.\nProgrammed Veeder Root console for monitoring and overfill protection.\n\nResponsibilities:\nContractor: Responsible for the delivery and installation of the fuel tank and associated components.\nResponsible for installing the piping, barriers, and fencing.\nResponsible for integrating the tank with the existing Veeder Root monitoring system.\nThe tank will be installed directly on the existing asphalt driveway.\nAll work is to be performed in compliance with relevant regulations and safety standards.\n\nEVALUATION FACTORS:\nVendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24526Q0377","place_of_performance":{"street":"Loch Raven MD VA Medical Center 3901 Loch Raven Blvd","country":{"code":"USA","name":"UNITED STATES"},"street2":"Baltimore, MD. 21218"},"product_service_code":"6680"}],"due_at":"2026-04-06T16:00:00Z","due_date":"2026-04-06","closes_at":"2026-04-06T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24005","county_name":"Baltimore County","city":"2459425","city_name":"Owings Mills","country":"USA","state_source":null,"state_evidence":"LOCH RAVEN MD VA MEDICAL CENTER 3901 LOCH RAVEN BLVD BALTIMORE, MD. 21218","site_key":null,"winner_key":"CV2FCG6V6BQ1","amount":null,"linked_awards":5,"cancelled":false,"archived":true,"updated_at":"2026-10-09T00:53:05.762210Z","principal_notice_id":"ba0e4bfdb51e4fd69ff890acd65c8239","description":{"text":"AMENDMENT TO SOLICITATION - 36C24526Q0377\n\nIt is being added to the STATEMENT OF WORK\n**The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.**\n\nB.2 STATEMENT OF WORK\nLR Boiler Reserve Fuel Tank\n\nSCOPE OF WORK:\nThe purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST). The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage.\n\nFuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings.\nSupport the piping properly and connect it to the existing piping outside the building at the sump.\n\nFuel Delivery: The owner will provide a fuel delivery to the tank.\nInstallation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank.\nSecured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access.\n\nIntegration with Existing Monitoring System:\nInstall a refurbished probe with a diesel and water float kit.\nInstall all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code.\nInstall an interstitial sensor in the tank secondary along with all necessary wiring and connections.\nProgram the existing Veeder Root console to monitor the diesel probe and sensor.\nProgram the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank.\n**The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.**\nDELIVERABLES:\n6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components.\nSecure fencing and traffic barriers to protect the tank.\n\nFuel Piping: Installed supply and return piping with necessary and compatible valves and fittings.\nMonitoring System Integration: Refurbished probe with diesel and water float kit.\nInstalled interstitial sensor and all necessary wiring.\nProgrammed Veeder Root console for monitoring and overfill protection.\n\nResponsibilities:\nContractor: Responsible for the delivery and installation of the fuel tank and associated components.\nResponsible for installing the piping, barriers, and fencing.\nResponsible for integrating the tank with the existing Veeder Root monitoring system.\nThe tank will be installed directly on the existing asphalt driveway.\nAll work is to be performed in compliance with relevant regulations and safety standards.\n\nEVALUATION FACTORS:\nVendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.","html":"AMENDMENT TO SOLICITATION - 36C24526Q0377\n\nIt is being added to the STATEMENT OF WORK\n**The contractor must provide a 1  thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2  radially from the support to distribute the load.**\n\nB.2 STATEMENT OF WORK \nLR Boiler Reserve Fuel Tank \n\nSCOPE OF WORK: \nThe purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST).  The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage. \n\nFuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings. \nSupport the piping properly and connect it to the existing piping outside the building at the sump. \n\nFuel Delivery: The owner will provide a fuel delivery to the tank. \nInstallation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank. \nSecured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access. \n\nIntegration with Existing Monitoring System: \nInstall a refurbished probe with a diesel and water float kit. \nInstall all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code. \nInstall an interstitial sensor in the tank secondary along with all necessary wiring and connections. \nProgram the existing Veeder Root console to monitor the diesel probe and sensor. \nProgram the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank. \n**The contractor must provide a 1  thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2  radially from the support to distribute the load.**\nDELIVERABLES: \n6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components. \nSecure fencing and traffic barriers to protect the tank. \n\nFuel Piping: Installed supply and return piping with necessary and compatible valves and fittings. \nMonitoring System Integration: Refurbished probe with diesel and water float kit. \nInstalled interstitial sensor and all necessary wiring. \nProgrammed Veeder Root console for monitoring and overfill protection. \n\nResponsibilities: \nContractor: Responsible for the delivery and installation of the fuel tank and associated components. \nResponsible for installing the piping, barriers, and fencing. \nResponsible for integrating the tank with the existing Veeder Root monitoring system. \nThe tank will be installed directly on the existing asphalt driveway. \nAll work is to be performed in compliance with relevant regulations and safety standards. \n\nEVALUATION FACTORS: \nVendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.","origin":"detail"},"contacts":[{"name":"Theresa Thomas","role":"primary","email":"theresa.thomas7@va.gov","title":"Contracting Officer"}],"place_of_performance":{"street":"Loch Raven MD VA Medical Center 3901 Loch Raven Blvd","country":{"code":"USA","name":"UNITED STATES"},"street2":"Baltimore, MD. 21218"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["333914"],"award":{"awardee":{}},"attachments":[{"resource_id":"527bd25afd754ee58bc02aa2513ed850","name":"36C24526Q0377_1.docx","kind":"file","mime_type":".docx","size_bytes":23828,"posted_at":"2026-03-23T17:50:50.103Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/527bd25afd754ee58bc02aa2513ed850/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24526P0378_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24526P0378_3600_-NONE-_-NONE-/","piid":"36C24526P0378","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"CV2FCG6V6BQ1","recipient_name":"DATANET ENGINEERING, INC.","recipient_uei":"CV2FCG6V6BQ1","recipient_cage":"0N4K1","recipient_city":"OWINGS MILLS","recipient_state":"MD","sub_name":"Department of Veterans Affairs","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","office_key":"o-36C245","first_action_date":"2026-05-04","last_action_date":"2026-09-14","actions":3,"obligated":"69250.00","current_total_value":"69250.00","potential_total_value":"69250.00","naics":"333914","psc":"6680","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":14,"description":"BOILER RESERVE FUEL TANK","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24526Q0377 equals the FPDS solicitation identifier","same awarding office 36C245"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"70ZU0327X51519B00","latest_notice_id":"96a3a4aa9cc84c60b912632a018f672b","title":"USCG Seawater Pumps","solicitation_number":"70ZU0327X51519B00","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-07T17:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZU03","office_name":"CG-SEA-C23","naics":"333914","psc":"4320","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"N0010426RTB38","latest_notice_id":"cf2e4b18b9214a48975c863638132efc","title":"43--PUMP UNIT,CENTRIFUG, IN REPAIR/MODIFICATION OF","solicitation_number":"N0010426RTB38","notice_type":"p","first_type":"p","first_posted":"2026-06-04","last_posted":"2026-10-28","notices":8,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333914","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"PP, TDP VER 004, QTY 10 EA, DELIVERY FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0010423RCD46","latest_notice_id":"03a7faaf0402477eabf291b681baca9d","title":"43--PUMP/MOTOR ASSY","solicitation_number":"N0010423RCD46","notice_type":"o","first_type":"o","first_posted":"2026-02-05","last_posted":"2026-10-28","notices":10,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333914","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4320)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":54,"indexable":false}