{"canonical":"https://sealedbidder.com/opportunities/36c24526q0256","key":"36C24526Q0256","url":"https://sealedbidder.com/opportunities/36c24526q0256","title":"6650--Scanning Systems: Laser: Optical Biometry","solicitation_number":"36C24526Q0256","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-20T17:00:00Z","first_posted":"2026-01-29","last_posted":"2026-01-29","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334510","psc":"6650","set_aside":null,"place_state":"WV","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"54099","place_county_name":"Wayne County","place_city":"5439460","place_city_name":"Huntington","winner":null,"award_amount":null,"publications":[{"notice_id":"fa6a276d6b884651922905f7d6d7f727","title":"6650--Scanning Systems: Laser: Optical Biometry","solicitation_number":"36C24526Q0256","notice_type":"r","base_type":"r","posted":"2026-01-29","posted_at":"2026-01-29T13:39:49.837Z","due_at":"2026-02-20T17:00:00Z","due_date":"2026-02-20","cancelled":false,"archived":true,"archive_date":"2026-04-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fa6a276d6b884651922905f7d6d7f727/view","enriched":true,"history":[{"index":3,"title":"6650--Scanning Systems: Laser: Optical Biometry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-29T13:39:49.837Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fa6a276d6b884651922905f7d6d7f727","solicitation_number":"36C24526Q0256"}]}],"latest_notice_id":"fa6a276d6b884651922905f7d6d7f727","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-01-29","posted_at":"2026-01-29T13:39:49.837Z","created_at":"2026-01-29T13:39:47.583Z","modified_at":"2026-04-22T03:55:46.031Z","response_deadline":{"raw":"2026-02-20T12:00:00-05:00","utc":"2026-02-20T17:00:00Z","date":"2026-02-20","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fa6a276d6b884651922905f7d6d7f727/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6650--Scanning Systems: Laser: Optical Biometry","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"6650--Scanning Systems: Laser: Optical Biometry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-29T13:39:49.837Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fa6a276d6b884651922905f7d6d7f727","solicitation_number":"36C24526Q0256"}],"contacts":[{"fax":"DYLAN GORE","name":"ALISON KLEIN","role":"primary","email":"ALISON.KLEIN@VA.GOV","phone":"304-623-3461 X 4143","title":"CONTRACTING OFFICER"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"fa6a276d6b884651922905f7d6d7f727","lineage_id":"fa6a276d6b884651922905f7d6d7f727","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T10:11:10.287722023Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"11e1d3f5970aa80966ff67c5a8a0eaf66338a2b5a3485598ae60e5d6ac63b5d9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T10:11:10.287722023Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â  Any resulting procurement action will be the subject of a separate, future announcement.Â  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs located at Huntington VAMC located at 150 Spring Valley Dr., Huntington, WV 25704 is seeking a Scanning System: Laser: Optical Biometry.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1,250 employees.\nSalient Characteristics:\nPerform accurate biometry, keratometry and intraocular calculations including toric lenses, especially in difficult cataract cases.  \n\nMeasurements must be obtained via non-contact.\n\nMeasurements obtained via two-dimensional swept-source OCT (SS-OCT).\n\nMust have ability to obtain biometry readings on dense cataracts.\n\n\nAutomated data transfer: \nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. \nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. \nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems i.e. VISTA. \nPhysical and Operational Requirements \nMust have a compact and ergonomical design. \nMust include patient positioning features. \nAdjustable chin rest.\nHead support for stable measurements. \nMust be compatible with standard U.S. electrical outlets. \nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â Any resulting procurement action will be the subject of a separate, future announcement.Â The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs located at Huntington VAMC located at 150 Spring Valley Dr., Huntington, WV 25704 is seeking a Scanning System: Laser: Optical Biometry.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1,250 employees.\nSalient Characteristics:\nPerform accurate biometry, keratometry and intraocular calculations including toric lenses, especially in difficult cataract cases.\n\nMeasurements must be obtained via non-contact.\n\nMeasurements obtained via two-dimensional swept-source OCT (SS-OCT).\n\nMust have ability to obtain biometry readings on dense cataracts.\n\nAutomated data transfer:\nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM.\nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa.\nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems i.e. VISTA.\nPhysical and Operational Requirements\nMust have a compact and ergonomical design.\nMust include patient positioning features.\nAdjustable chin rest.\nHead support for stable measurements.\nMust be compatible with standard U.S. electrical outlets.\nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0256","place_of_performance":{"zip":"25704","city":{"code":"39460","name":"Huntington"},"state":{"code":"WV","name":"West Virginia"},"street":"HUNTINGTON VAMC 1540 SPRING VALLEY DR","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6650"}],"due_at":"2026-02-20T17:00:00Z","due_date":"2026-02-20","closes_at":"2026-02-20T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"WV","county":"54099","county_name":"Wayne County","city":"5439460","city_name":"Huntington","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-14T10:59:08.380935Z","principal_notice_id":"fa6a276d6b884651922905f7d6d7f727","description":{"text":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â Any resulting procurement action will be the subject of a separate, future announcement.Â The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs located at Huntington VAMC located at 150 Spring Valley Dr., Huntington, WV 25704 is seeking a Scanning System: Laser: Optical Biometry.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1,250 employees.\nSalient Characteristics:\nPerform accurate biometry, keratometry and intraocular calculations including toric lenses, especially in difficult cataract cases.\n\nMeasurements must be obtained via non-contact.\n\nMeasurements obtained via two-dimensional swept-source OCT (SS-OCT).\n\nMust have ability to obtain biometry readings on dense cataracts.\n\nAutomated data transfer:\nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM.\nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa.\nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems i.e. VISTA.\nPhysical and Operational Requirements\nMust have a compact and ergonomical design.\nMust include patient positioning features.\nAdjustable chin rest.\nHead support for stable measurements.\nMust be compatible with standard U.S. electrical outlets.\nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"REQUEST FOR INFORMATION\n\nThis RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government.Â  Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract.Â  Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice.Â  No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information.Â  At this time, no solicitation exists; therefore, please do not request a copy of the solicitation.Â  Any resulting procurement action will be the subject of a separate, future announcement.Â  The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release.Â  The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.\n\nThe Department of Veteran Affairs located at Huntington VAMC located at 150 Spring Valley Dr., Huntington, WV 25704 is seeking a Scanning System: Laser: Optical Biometry.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard is 1,250 employees.\nSalient Characteristics:\nPerform accurate biometry, keratometry and intraocular calculations including toric lenses, especially in difficult cataract cases.  \n\nMeasurements must be obtained via non-contact.\n\nMeasurements obtained via two-dimensional swept-source OCT (SS-OCT).\n\nMust have ability to obtain biometry readings on dense cataracts.\n\n\nAutomated data transfer: \nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. \nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. \nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems i.e. VISTA. \nPhysical and Operational Requirements \nMust have a compact and ergonomical design. \nMust include patient positioning features. \nAdjustable chin rest.\nHead support for stable measurements. \nMust be compatible with standard U.S. electrical outlets. \nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.\nResponses:\n\nThe response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products MUST COMPLETE THIS SECTION\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"fax":"DYLAN GORE","name":"ALISON KLEIN","role":"primary","email":"ALISON.KLEIN@VA.GOV","phone":"304-623-3461 X 4143","title":"CONTRACTING OFFICER"}],"place_of_performance":{"zip":"25704","city":{"code":"39460","name":"Huntington"},"state":{"code":"WV","name":"West Virginia"},"street":"HUNTINGTON VAMC 1540 SPRING VALLEY DR","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"a5d00f4ccfc54cb1a4246f724526b82b","name":"36C24526Q0256.docx","kind":"file","mime_type":".docx","size_bytes":28298,"posted_at":"2026-01-29T13:39:49.837Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a5d00f4ccfc54cb1a4246f724526b82b/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"REQTIHS202600220","latest_notice_id":"ef16a1513b85491d928fcb190b3fe772","title":"Vital Signs Monitoring and Physical Assessment Units","solicitation_number":"REQT-IHS-2026-00220","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-26T01:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H713","office_name":"INDIAN HEALTH SERVICE","naics":"334510","psc":"6515","set_aside":null,"state":"OR","county":"41047","county_name":"Marion County","city":"4164900","city_name":"Salem","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open_total":12,"indexable":false}