{"canonical":"https://sealedbidder.com/opportunities/36c24526q0190","key":"36C24526Q0190","url":"https://sealedbidder.com/opportunities/36c24526q0190","title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","solicitation_number":"36C24526Q0190","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":null,"first_posted":"2025-12-17","last_posted":"2026-02-04","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"811210","psc":"J065","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":"GE PRECISION HEALTHCARE LLC","award_amount":"100288.68","publications":[{"notice_id":"cf15657665ed4996a00b571db0514380","title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","solicitation_number":"36C24526Q0190","notice_type":"s","base_type":"s","posted":"2025-12-17","posted_at":"2025-12-17T17:16:39.069Z","due_at":"2025-12-31T18:00:00Z","due_date":"2025-12-31","cancelled":false,"archived":true,"archive_date":"2026-03-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cf15657665ed4996a00b571db0514380/view","enriched":true,"history":[{"index":6,"title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T18:25:13.844Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"068dcf903f214ab6a9c0c4424d6381c4","solicitation_number":"36C24526Q0190","related_opportunity_id":"cf15657665ed4996a00b571db0514380"},{"index":4,"title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-17T17:16:39.069Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cf15657665ed4996a00b571db0514380","solicitation_number":"36C24526Q0190"}]},{"notice_id":"068dcf903f214ab6a9c0c4424d6381c4","title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","solicitation_number":"36C24526Q0190","notice_type":"a","base_type":"s","posted":"2026-02-04","posted_at":"2026-02-04T18:25:13.844Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-04-05","removed_at":null,"award_number":"VA797H17D002436C24526F0107","awardee_name":"GE PRECISION HEALTHCARE LLC","amount":"100288.68","link_sam":"https://sam.gov/workspace/contract/opp/068dcf903f214ab6a9c0c4424d6381c4/view","enriched":true,"history":[{"index":6,"title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T18:25:13.844Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"068dcf903f214ab6a9c0c4424d6381c4","solicitation_number":"36C24526Q0190","related_opportunity_id":"cf15657665ed4996a00b571db0514380"},{"index":4,"title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-17T17:16:39.069Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cf15657665ed4996a00b571db0514380","solicitation_number":"36C24526Q0190"}]}],"latest_notice_id":"068dcf903f214ab6a9c0c4424d6381c4","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-12-17","posted_at":"2025-12-17T17:16:39.069Z","created_at":"2025-12-17T17:16:36.834Z","modified_at":"2026-03-02T04:55:44.818Z","response_deadline":{"raw":"2025-12-31T13:00:00-05:00","utc":"2025-12-31T18:00:00Z","date":"2025-12-31","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cf15657665ed4996a00b571db0514380/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-01","archive_type":"auto_custom"},"history":[{"index":6,"title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T18:25:13.844Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"068dcf903f214ab6a9c0c4424d6381c4","solicitation_number":"36C24526Q0190","related_opportunity_id":"cf15657665ed4996a00b571db0514380"},{"index":4,"title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-17T17:16:39.069Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cf15657665ed4996a00b571db0514380","solicitation_number":"36C24526Q0190"}],"contacts":[{"fax":"NONE","name":"AMY WALTER","role":"primary","email":"AMY.WALTER1@VA.GOV","phone":"NONE","title":"CONTRACTING OFFICER"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"cf15657665ed4996a00b571db0514380","lineage_id":"cf15657665ed4996a00b571db0514380","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T00:05:03.708162544Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"2a653f40742bf53502a8fc0fae87ce397082d39ea91f8f7b4858f94e9ea240ab","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T00:05:03.708162544Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Statement of Work   613-26-1-034-0013\nGE OEC and ULTRASOUND\nMARTINSBURG VA MEDICAL CENTER\nRADIOLOGY DEPARTMENT\nMARTINSBURG, WV 25405\n\nTABLE OF CONTENTS\n1.0     Introduction\n1.1.1    Scope of Work\n1.1.2     Non-Personal Services\n1.2           Communication\n1.3        Safety\n1.4         Performance Reports\n1.5          Technical Requirements\n1.6         Professional Qualifications\n1.7         Specific Task/Responsibilities\n1.8        Period of Performance\n1.9         Place/Hours of Performance\n1.1        Holidays\n1.11      Contractor Provided Services\n2.0      Definitions/Acronyms\n3.0            Applicable Technical Orders, Manuals, Regulations, Directives and Forms\n3.1     Mandatory Documents\n3.2     Other Requirements\n\nINTRODUCTION: The Contractor shall provide maintenance support for the VA Medical Center, Martinsburg WV. The services provided will be of nature and scope described in the paragraphs below.\n\n1.1.1  SCOPE OF WORK: This is a Base plus four option years  service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised. The purpose of this requirement is to Perform Preventive Maintenance and Repair on GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619, and their associated components located at the VA Medical Center, Martinsburg, WV 25405.\n\n1.1.2    NON-PERSONAL SERVICES: This contract is a non-personal services contract under which the personnel rendering the services are not subject, either by the contract's terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the Government and its employees.\n\n1.2 COMMUNICATION: The contractor's employee shall be able to read, write, understand and speak English clearly, to effectively communicate with patients and/or other healthcare providers and staff.\n\n1.3 SAFETY: The Contractor shall be responsible for knowing and complying with all installation safety prevention regulations. Such regulations include, but are not limited to, general safety, fire prevention, and waste disposal.\n\n1.4 PERFORMANCE REPORTS: Reports will be provided by the COR to ensure acceptable performance of the contract. Annual reports provided by COR to Contracting Officer after completion of each performance period will be reported to the DOD Contractor Performance Assessment Reporting System (CPARS).\n\n1.5 TECHNICAL REQUIREMENTS: All Contractor employees provided by the Contractor shall meet the qualifications for that specialty and perform essentially the same functions, within the scope acceptable for their professional discipline and standard, as those required by the Department of Veterans Affairs or Government service health care professionals of similar experience and in similar duty assignments.\n\n1.6 PROFESSIONAL QUALIFICATIONS: Personnel shall have current factory training and experience in the servicing GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619and their associated components that includes maintenance, repair and software/hardware upgrades.\n\n1.7 SPECIFIC TASK AND RESPONSIBILITIES: The Contractor shall provide Preventive Maintenance Inspections (PMIs), for the GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619 and their associated components.\n1.7.1 CUSTOMER SUPPORT:  The GE Healthcare Customer Service Department provides an all-inclusive contract that includes the following services.\nPriority scheduling for service calls\nUnlimited Technical Services (24x7) Telephone Support\n On-site field service maintenance\nSoftware updates\nHardware updates that fix an Assist defined functionality problem\n Virus protection updates\n Operating system patches\n Ongoing interface maintenance\n1.7.2 DIAGNOSTIC AND ISSUE RESOLUTION: The GE Healthcare Customer Service Department provides diagnostic and resolution services that include the following:\nDiagnosis/FboNotice cause analysis\nDefined resolution approach: workaround or fix\nOperator instruction on actions to be taken on the customer's end to correct the        problem\nCorrection of errors/defects in the programs\nCorrection of configuration errors\nCorrection of errors in the standard software through the sourcing, testing, and implementation of patches and service packs provided by software providers\nCorrection of interfaces and custom reports\nQuality/training initiatives to increase operator knowledge and decrease the number of incoming incidents\n1.7.7 PART REPLACEMENT: All parts, labor, and travel to perform maintenance service and repairs (preventive or corrective) are included in this Maintenance Agreement.  Parts requiring replacement to maintain the equipment in accordance with GE Specifications will be replaced on a new part basis.  Notification needs to be given to the COR of any equipment being replaced.\n\n1.8 PERIOD OF PERFORMANCE:01OCT2023 TO 30SEP2028Â  Â \nThis is a Base plus four option years  service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised.\n1.9 PLACE/HOURS OF PERFORMANCE/NORMAL BUSINESS HOURS: The place of performance is the Surgical and Imaging Departments located at VA Medical Center, 510 Butler Ave, Martinsburg, WV 25405. Contract providers shall perform repair services Monday through Friday, between 8:00 AM and 4:30 PM EST, excluding holidays.\n1.10 HOLIDAYS: The following legal holidays are observed by Martinsburg VA Medical Center:\nNew Year's Day\nMartin Luther King's Birthday \n President's Day \nMemorial Day \nJuneteenthÂ \nIndependence Day \nLabor Day \nColumbus Day \nVeteran's Day \nThanksgiving Day \n Christmas Day \n\nNOTE: Any of the above holidays falling on a Saturday will be observed on the preceding Friday; holidays falling on a Sunday will be observed on the following Monday. Any holidays that are declared by Presidential Executive Order shall be observed in the same manner as the holidays listed above. \n1.11.1 SERVICE REPORTS: A copy of the service report, complete with test data, will be furnished to the COR within 5 working days after completion of a PMI or Corrective Maintenance.\n1.12 CONTRACTOR PROVIDED SERVICES:\n1.12.1 The Contractor shall furnish all personnel and services to comply with the requirements of this contract.  The Contractor will report to Biomed to be escorted to the equipment.  The Contractor will converse with Biomed prior to exiting the building.  He/she will provide an update of the equipment status and what work was performed.\n1.12.2 POINT OF CONTACT: Upon award, the Contractor shall designate, in writing  and provide to the COR and Contracting Officer, the name and telephone number of the point of contact for all actions on this requirement.\n2.0 DEFINITIONS/ACRONYMS:\nCONTRACTING OFFICER (CO): A person with the authority to enter into, administer, and/or terminate contracts and make related determinations and findings on contracts.\nCONTRACTING OFFICER'S REPRESENTATIVE (COR): A Government employee, appointed in writing and within the limits of authority as delegated by the contracting officer, authorized to act as his representative in monitoring a contract.\nQUALITY ASSESSMENT AND IMPROVEMENT (QA&I): An ongoing program designed to objectively and systematically monitor and evaluate the quality and appropriateness of patient care, to pursue opportunities to improve patient care, and to resolve identified problems\nQUALITY CONTROL: Those actions taken by the Contractor to control and ensure that performance of duties meet the requirements of the contract.\n\n3.0        APPLICABLE TECHNICAL ORDERS, MANUALS, REGULATIONS, DIRECTIVES AND FORMS: All applicable directives and publications (advisory or mandatory), and supplements or amendments to these directives and publications will be current when furnished to the contractor. Directives will be available to contractor upon request.\n   \n3.1     The Contractor is required to follow all mandatory documents to the extent they apply to this contract. Any such changes to mandatory publications that cause a change in the scope of performance will not be implemented by the contractor until the Contracting Officer issues a modification in writing. \n\n3.2    All Test Equipment utilized must meet NIST and ISO 9001 standards.  Technicians must provide proof of calibration of instrumentation upon before or upon arrival.  All invoices must contain the model, serial number and calibration date/due of test equipment utilized.  The C&A Requirements do not apply and that a Security Accreditation Package is not required.","text":"Statement of Work 613-26-1-034-0013\nGE OEC and ULTRASOUND\nMARTINSBURG VA MEDICAL CENTER\nRADIOLOGY DEPARTMENT\nMARTINSBURG, WV 25405\n\nTABLE OF CONTENTS\n1.0 Introduction\n1.1.1 Scope of Work\n1.1.2 Non-Personal Services\n1.2 Communication\n1.3 Safety\n1.4 Performance Reports\n1.5 Technical Requirements\n1.6 Professional Qualifications\n1.7 Specific Task/Responsibilities\n1.8 Period of Performance\n1.9 Place/Hours of Performance\n1.1 Holidays\n1.11 Contractor Provided Services\n2.0 Definitions/Acronyms\n3.0 Applicable Technical Orders, Manuals, Regulations, Directives and Forms\n3.1 Mandatory Documents\n3.2 Other Requirements\n\nINTRODUCTION: The Contractor shall provide maintenance support for the VA Medical Center, Martinsburg WV. The services provided will be of nature and scope described in the paragraphs below.\n\n1.1.1 SCOPE OF WORK: This is a Base plus four option years service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised. The purpose of this requirement is to Perform Preventive Maintenance and Repair on GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619, and their associated components located at the VA Medical Center, Martinsburg, WV 25405.\n\n1.1.2 NON-PERSONAL SERVICES: This contract is a non-personal services contract under which the personnel rendering the services are not subject, either by the contract's terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the Government and its employees.\n\n1.2 COMMUNICATION: The contractor's employee shall be able to read, write, understand and speak English clearly, to effectively communicate with patients and/or other healthcare providers and staff.\n\n1.3 SAFETY: The Contractor shall be responsible for knowing and complying with all installation safety prevention regulations. Such regulations include, but are not limited to, general safety, fire prevention, and waste disposal.\n\n1.4 PERFORMANCE REPORTS: Reports will be provided by the COR to ensure acceptable performance of the contract. Annual reports provided by COR to Contracting Officer after completion of each performance period will be reported to the DOD Contractor Performance Assessment Reporting System (CPARS).\n\n1.5 TECHNICAL REQUIREMENTS: All Contractor employees provided by the Contractor shall meet the qualifications for that specialty and perform essentially the same functions, within the scope acceptable for their professional discipline and standard, as those required by the Department of Veterans Affairs or Government service health care professionals of similar experience and in similar duty assignments.\n\n1.6 PROFESSIONAL QUALIFICATIONS: Personnel shall have current factory training and experience in the servicing GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619and their associated components that includes maintenance, repair and software/hardware upgrades.\n\n1.7 SPECIFIC TASK AND RESPONSIBILITIES: The Contractor shall provide Preventive Maintenance Inspections (PMIs), for the GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619 and their associated components.\n1.7.1 CUSTOMER SUPPORT: The GE Healthcare Customer Service Department provides an all-inclusive contract that includes the following services.\nPriority scheduling for service calls\nUnlimited Technical Services (24x7) Telephone Support\nOn-site field service maintenance\nSoftware updates\nHardware updates that fix an Assist defined functionality problem\nVirus protection updates\nOperating system patches\nOngoing interface maintenance\n1.7.2 DIAGNOSTIC AND ISSUE RESOLUTION: The GE Healthcare Customer Service Department provides diagnostic and resolution services that include the following:\nDiagnosis/FboNotice cause analysis\nDefined resolution approach: workaround or fix\nOperator instruction on actions to be taken on the customer's end to correct the problem\nCorrection of errors/defects in the programs\nCorrection of configuration errors\nCorrection of errors in the standard software through the sourcing, testing, and implementation of patches and service packs provided by software providers\nCorrection of interfaces and custom reports\nQuality/training initiatives to increase operator knowledge and decrease the number of incoming incidents\n1.7.7 PART REPLACEMENT: All parts, labor, and travel to perform maintenance service and repairs (preventive or corrective) are included in this Maintenance Agreement. Parts requiring replacement to maintain the equipment in accordance with GE Specifications will be replaced on a new part basis. Notification needs to be given to the COR of any equipment being replaced.\n\n1.8 PERIOD OF PERFORMANCE:01OCT2023 TO 30SEP2028Â Â\nThis is a Base plus four option years service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised.\n1.9 PLACE/HOURS OF PERFORMANCE/NORMAL BUSINESS HOURS: The place of performance is the Surgical and Imaging Departments located at VA Medical Center, 510 Butler Ave, Martinsburg, WV 25405. Contract providers shall perform repair services Monday through Friday, between 8:00 AM and 4:30 PM EST, excluding holidays.\n1.10 HOLIDAYS: The following legal holidays are observed by Martinsburg VA Medical Center:\nNew Year's Day\nMartin Luther King's Birthday\nPresident's Day\nMemorial Day\nJuneteenthÂ\nIndependence Day\nLabor Day\nColumbus Day\nVeteran's Day\nThanksgiving Day\nChristmas Day\n\nNOTE: Any of the above holidays falling on a Saturday will be observed on the preceding Friday; holidays falling on a Sunday will be observed on the following Monday. Any holidays that are declared by Presidential Executive Order shall be observed in the same manner as the holidays listed above.\n1.11.1 SERVICE REPORTS: A copy of the service report, complete with test data, will be furnished to the COR within 5 working days after completion of a PMI or Corrective Maintenance.\n1.12 CONTRACTOR PROVIDED SERVICES:\n1.12.1 The Contractor shall furnish all personnel and services to comply with the requirements of this contract. The Contractor will report to Biomed to be escorted to the equipment. The Contractor will converse with Biomed prior to exiting the building. He/she will provide an update of the equipment status and what work was performed.\n1.12.2 POINT OF CONTACT: Upon award, the Contractor shall designate, in writing and provide to the COR and Contracting Officer, the name and telephone number of the point of contact for all actions on this requirement.\n2.0 DEFINITIONS/ACRONYMS:\nCONTRACTING OFFICER (CO): A person with the authority to enter into, administer, and/or terminate contracts and make related determinations and findings on contracts.\nCONTRACTING OFFICER'S REPRESENTATIVE (COR): A Government employee, appointed in writing and within the limits of authority as delegated by the contracting officer, authorized to act as his representative in monitoring a contract.\nQUALITY ASSESSMENT AND IMPROVEMENT (QA&I): An ongoing program designed to objectively and systematically monitor and evaluate the quality and appropriateness of patient care, to pursue opportunities to improve patient care, and to resolve identified problems\nQUALITY CONTROL: Those actions taken by the Contractor to control and ensure that performance of duties meet the requirements of the contract.\n\n3.0 APPLICABLE TECHNICAL ORDERS, MANUALS, REGULATIONS, DIRECTIVES AND FORMS: All applicable directives and publications (advisory or mandatory), and supplements or amendments to these directives and publications will be current when furnished to the contractor. Directives will be available to contractor upon request.\n\n3.1 The Contractor is required to follow all mandatory documents to the extent they apply to this contract. Any such changes to mandatory publications that cause a change in the scope of performance will not be implemented by the contractor until the Contracting Officer issues a modification in writing.\n\n3.2 All Test Equipment utilized must meet NIST and ISO 9001 standards. Technicians must provide proof of calibration of instrumentation upon before or upon arrival. All invoices must contain the model, serial number and calibration date/due of test equipment utilized. The C&A Requirements do not apply and that a Security Accreditation Package is not required.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24526Q0190","product_service_code":"J065"},{"award":{"date":"2026-01-30","amount":"100288.68","number":"VA797H17D002436C24526F0107","awardee":{"raw":"GE PRECISION HEALTHCARE LLC WAUKESHA 53188","uei":"JJURYE5M19G1","cage":"9CB48","name":"GE PRECISION HEALTHCARE LLC","location":{"zip":"53188","city":{"name":"WAUKESHA"},"state":{"name":"WI"},"country":{"name":"WI"}}}},"dates":{"posted":"2026-02-04","posted_at":"2026-02-04T18:25:13.844Z","award_date":"2026-01-30","created_at":"2026-02-04T18:25:11.289Z","modified_at":"2026-04-06T03:55:45.461Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/068dcf903f214ab6a9c0c4424d6381c4/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-05","archive_type":"auto_custom"},"history":[{"index":6,"title":"J065--613C60084 | 01/31/2026-01/30/2027 | GE OEC and Ultrasound (VA-26-00008460) | SOLE SOURCE FOR BASE AND FOUR OPTION YEARS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T18:25:13.844Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"068dcf903f214ab6a9c0c4424d6381c4","solicitation_number":"36C24526Q0190","related_opportunity_id":"cf15657665ed4996a00b571db0514380"},{"index":4,"title":"J065--INTENT TO SOLE SOURCE WITH OEM GE HEALTHCARE | BASE PLUS FOUR OPTION YEARS | 01/01/2026 TO 12/31/2026 (12/31/2031) | GE OEC and Ultrasound (VA-26-00008460)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-17T17:16:39.069Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"cf15657665ed4996a00b571db0514380","solicitation_number":"36C24526Q0190"}],"contacts":[{"fax":"NONE","name":"AMY WALTER","role":"primary","email":"AMY.WALTER1@VA.GOV","phone":"NONE","title":"CONTRACTING OFFICER"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"068dcf903f214ab6a9c0c4424d6381c4","lineage_id":"cf15657665ed4996a00b571db0514380","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T03:16:54.905377439Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"96986b395bde971c89c80802a0a431f9bd40ed7eaae90760a7fc4fd16183337e","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T03:16:54.905377439Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24526Q0190","place_of_performance":{"zip":"21201","city":{"name":"Baltimore"},"state":{"name":"MD"},"street":"Department of Veterans Affairs VAMC","street2":"10 N Greene St"},"product_service_code":"J065"}],"due_at":null,"due_date":null,"closes_at":null,"awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"JJURYE5M19G1","amount":"100288.68","linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-14T03:57:08.970241Z","principal_notice_id":"cf15657665ed4996a00b571db0514380","description":{"text":"Statement of Work 613-26-1-034-0013\nGE OEC and ULTRASOUND\nMARTINSBURG VA MEDICAL CENTER\nRADIOLOGY DEPARTMENT\nMARTINSBURG, WV 25405\n\nTABLE OF CONTENTS\n1.0 Introduction\n1.1.1 Scope of Work\n1.1.2 Non-Personal Services\n1.2 Communication\n1.3 Safety\n1.4 Performance Reports\n1.5 Technical Requirements\n1.6 Professional Qualifications\n1.7 Specific Task/Responsibilities\n1.8 Period of Performance\n1.9 Place/Hours of Performance\n1.1 Holidays\n1.11 Contractor Provided Services\n2.0 Definitions/Acronyms\n3.0 Applicable Technical Orders, Manuals, Regulations, Directives and Forms\n3.1 Mandatory Documents\n3.2 Other Requirements\n\nINTRODUCTION: The Contractor shall provide maintenance support for the VA Medical Center, Martinsburg WV. The services provided will be of nature and scope described in the paragraphs below.\n\n1.1.1 SCOPE OF WORK: This is a Base plus four option years service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised. The purpose of this requirement is to Perform Preventive Maintenance and Repair on GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619, and their associated components located at the VA Medical Center, Martinsburg, WV 25405.\n\n1.1.2 NON-PERSONAL SERVICES: This contract is a non-personal services contract under which the personnel rendering the services are not subject, either by the contract's terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the Government and its employees.\n\n1.2 COMMUNICATION: The contractor's employee shall be able to read, write, understand and speak English clearly, to effectively communicate with patients and/or other healthcare providers and staff.\n\n1.3 SAFETY: The Contractor shall be responsible for knowing and complying with all installation safety prevention regulations. Such regulations include, but are not limited to, general safety, fire prevention, and waste disposal.\n\n1.4 PERFORMANCE REPORTS: Reports will be provided by the COR to ensure acceptable performance of the contract. Annual reports provided by COR to Contracting Officer after completion of each performance period will be reported to the DOD Contractor Performance Assessment Reporting System (CPARS).\n\n1.5 TECHNICAL REQUIREMENTS: All Contractor employees provided by the Contractor shall meet the qualifications for that specialty and perform essentially the same functions, within the scope acceptable for their professional discipline and standard, as those required by the Department of Veterans Affairs or Government service health care professionals of similar experience and in similar duty assignments.\n\n1.6 PROFESSIONAL QUALIFICATIONS: Personnel shall have current factory training and experience in the servicing GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619and their associated components that includes maintenance, repair and software/hardware upgrades.\n\n1.7 SPECIFIC TASK AND RESPONSIBILITIES: The Contractor shall provide Preventive Maintenance Inspections (PMIs), for the GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619 and their associated components.\n1.7.1 CUSTOMER SUPPORT: The GE Healthcare Customer Service Department provides an all-inclusive contract that includes the following services.\nPriority scheduling for service calls\nUnlimited Technical Services (24x7) Telephone Support\nOn-site field service maintenance\nSoftware updates\nHardware updates that fix an Assist defined functionality problem\nVirus protection updates\nOperating system patches\nOngoing interface maintenance\n1.7.2 DIAGNOSTIC AND ISSUE RESOLUTION: The GE Healthcare Customer Service Department provides diagnostic and resolution services that include the following:\nDiagnosis/FboNotice cause analysis\nDefined resolution approach: workaround or fix\nOperator instruction on actions to be taken on the customer's end to correct the problem\nCorrection of errors/defects in the programs\nCorrection of configuration errors\nCorrection of errors in the standard software through the sourcing, testing, and implementation of patches and service packs provided by software providers\nCorrection of interfaces and custom reports\nQuality/training initiatives to increase operator knowledge and decrease the number of incoming incidents\n1.7.7 PART REPLACEMENT: All parts, labor, and travel to perform maintenance service and repairs (preventive or corrective) are included in this Maintenance Agreement. Parts requiring replacement to maintain the equipment in accordance with GE Specifications will be replaced on a new part basis. Notification needs to be given to the COR of any equipment being replaced.\n\n1.8 PERIOD OF PERFORMANCE:01OCT2023 TO 30SEP2028Â Â\nThis is a Base plus four option years service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised.\n1.9 PLACE/HOURS OF PERFORMANCE/NORMAL BUSINESS HOURS: The place of performance is the Surgical and Imaging Departments located at VA Medical Center, 510 Butler Ave, Martinsburg, WV 25405. Contract providers shall perform repair services Monday through Friday, between 8:00 AM and 4:30 PM EST, excluding holidays.\n1.10 HOLIDAYS: The following legal holidays are observed by Martinsburg VA Medical Center:\nNew Year's Day\nMartin Luther King's Birthday\nPresident's Day\nMemorial Day\nJuneteenthÂ\nIndependence Day\nLabor Day\nColumbus Day\nVeteran's Day\nThanksgiving Day\nChristmas Day\n\nNOTE: Any of the above holidays falling on a Saturday will be observed on the preceding Friday; holidays falling on a Sunday will be observed on the following Monday. Any holidays that are declared by Presidential Executive Order shall be observed in the same manner as the holidays listed above.\n1.11.1 SERVICE REPORTS: A copy of the service report, complete with test data, will be furnished to the COR within 5 working days after completion of a PMI or Corrective Maintenance.\n1.12 CONTRACTOR PROVIDED SERVICES:\n1.12.1 The Contractor shall furnish all personnel and services to comply with the requirements of this contract. The Contractor will report to Biomed to be escorted to the equipment. The Contractor will converse with Biomed prior to exiting the building. He/she will provide an update of the equipment status and what work was performed.\n1.12.2 POINT OF CONTACT: Upon award, the Contractor shall designate, in writing and provide to the COR and Contracting Officer, the name and telephone number of the point of contact for all actions on this requirement.\n2.0 DEFINITIONS/ACRONYMS:\nCONTRACTING OFFICER (CO): A person with the authority to enter into, administer, and/or terminate contracts and make related determinations and findings on contracts.\nCONTRACTING OFFICER'S REPRESENTATIVE (COR): A Government employee, appointed in writing and within the limits of authority as delegated by the contracting officer, authorized to act as his representative in monitoring a contract.\nQUALITY ASSESSMENT AND IMPROVEMENT (QA&I): An ongoing program designed to objectively and systematically monitor and evaluate the quality and appropriateness of patient care, to pursue opportunities to improve patient care, and to resolve identified problems\nQUALITY CONTROL: Those actions taken by the Contractor to control and ensure that performance of duties meet the requirements of the contract.\n\n3.0 APPLICABLE TECHNICAL ORDERS, MANUALS, REGULATIONS, DIRECTIVES AND FORMS: All applicable directives and publications (advisory or mandatory), and supplements or amendments to these directives and publications will be current when furnished to the contractor. Directives will be available to contractor upon request.\n\n3.1 The Contractor is required to follow all mandatory documents to the extent they apply to this contract. Any such changes to mandatory publications that cause a change in the scope of performance will not be implemented by the contractor until the Contracting Officer issues a modification in writing.\n\n3.2 All Test Equipment utilized must meet NIST and ISO 9001 standards. Technicians must provide proof of calibration of instrumentation upon before or upon arrival. All invoices must contain the model, serial number and calibration date/due of test equipment utilized. The C&A Requirements do not apply and that a Security Accreditation Package is not required.","html":"Statement of Work   613-26-1-034-0013\nGE OEC and ULTRASOUND\nMARTINSBURG VA MEDICAL CENTER\nRADIOLOGY DEPARTMENT\nMARTINSBURG, WV 25405\n\nTABLE OF CONTENTS\n1.0     Introduction\n1.1.1    Scope of Work\n1.1.2     Non-Personal Services\n1.2           Communication\n1.3        Safety\n1.4         Performance Reports\n1.5          Technical Requirements\n1.6         Professional Qualifications\n1.7         Specific Task/Responsibilities\n1.8        Period of Performance\n1.9         Place/Hours of Performance\n1.1        Holidays\n1.11      Contractor Provided Services\n2.0      Definitions/Acronyms\n3.0            Applicable Technical Orders, Manuals, Regulations, Directives and Forms\n3.1     Mandatory Documents\n3.2     Other Requirements\n\nINTRODUCTION: The Contractor shall provide maintenance support for the VA Medical Center, Martinsburg WV. The services provided will be of nature and scope described in the paragraphs below.\n\n1.1.1  SCOPE OF WORK: This is a Base plus four option years  service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised. The purpose of this requirement is to Perform Preventive Maintenance and Repair on GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619, and their associated components located at the VA Medical Center, Martinsburg, WV 25405.\n\n1.1.2    NON-PERSONAL SERVICES: This contract is a non-personal services contract under which the personnel rendering the services are not subject, either by the contract's terms or by the manner of its administration, to the supervision and control usually prevailing in relationships between the Government and its employees.\n\n1.2 COMMUNICATION: The contractor's employee shall be able to read, write, understand and speak English clearly, to effectively communicate with patients and/or other healthcare providers and staff.\n\n1.3 SAFETY: The Contractor shall be responsible for knowing and complying with all installation safety prevention regulations. Such regulations include, but are not limited to, general safety, fire prevention, and waste disposal.\n\n1.4 PERFORMANCE REPORTS: Reports will be provided by the COR to ensure acceptable performance of the contract. Annual reports provided by COR to Contracting Officer after completion of each performance period will be reported to the DOD Contractor Performance Assessment Reporting System (CPARS).\n\n1.5 TECHNICAL REQUIREMENTS: All Contractor employees provided by the Contractor shall meet the qualifications for that specialty and perform essentially the same functions, within the scope acceptable for their professional discipline and standard, as those required by the Department of Veterans Affairs or Government service health care professionals of similar experience and in similar duty assignments.\n\n1.6 PROFESSIONAL QUALIFICATIONS: Personnel shall have current factory training and experience in the servicing GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619and their associated components that includes maintenance, repair and software/hardware upgrades.\n\n1.7 SPECIFIC TASK AND RESPONSIBILITIES: The Contractor shall provide Preventive Maintenance Inspections (PMIs), for the GE OEC serial number FAXXTE01109, GE OEC Elite serial number FAXXTE01110, GE OEC Elite serial number FBMHTX00453, LOGIQ E10 serial number LE10502107US7, GE LOGIQ E10 serial number LE10502088US7, GE LOGIQ S8 serial number LS8506619 and their associated components.\n1.7.1 CUSTOMER SUPPORT:  The GE Healthcare Customer Service Department provides an all-inclusive contract that includes the following services.\nPriority scheduling for service calls\nUnlimited Technical Services (24x7) Telephone Support\n On-site field service maintenance\nSoftware updates\nHardware updates that fix an Assist defined functionality problem\n Virus protection updates\n Operating system patches\n Ongoing interface maintenance\n1.7.2 DIAGNOSTIC AND ISSUE RESOLUTION: The GE Healthcare Customer Service Department provides diagnostic and resolution services that include the following:\nDiagnosis/FboNotice cause analysis\nDefined resolution approach: workaround or fix\nOperator instruction on actions to be taken on the customer's end to correct the        problem\nCorrection of errors/defects in the programs\nCorrection of configuration errors\nCorrection of errors in the standard software through the sourcing, testing, and implementation of patches and service packs provided by software providers\nCorrection of interfaces and custom reports\nQuality/training initiatives to increase operator knowledge and decrease the number of incoming incidents\n1.7.7 PART REPLACEMENT: All parts, labor, and travel to perform maintenance service and repairs (preventive or corrective) are included in this Maintenance Agreement.  Parts requiring replacement to maintain the equipment in accordance with GE Specifications will be replaced on a new part basis.  Notification needs to be given to the COR of any equipment being replaced.\n\n1.8 PERIOD OF PERFORMANCE:01OCT2023 TO 30SEP2028Â  Â \nThis is a Base plus four option years  service contract Performance Period Dates Price Base Year: Option Year One: Option Year Two: Option Year Three: Option Year Four: Option years may be exercised.\n1.9 PLACE/HOURS OF PERFORMANCE/NORMAL BUSINESS HOURS: The place of performance is the Surgical and Imaging Departments located at VA Medical Center, 510 Butler Ave, Martinsburg, WV 25405. Contract providers shall perform repair services Monday through Friday, between 8:00 AM and 4:30 PM EST, excluding holidays.\n1.10 HOLIDAYS: The following legal holidays are observed by Martinsburg VA Medical Center:\nNew Year's Day\nMartin Luther King's Birthday \n President's Day \nMemorial Day \nJuneteenthÂ \nIndependence Day \nLabor Day \nColumbus Day \nVeteran's Day \nThanksgiving Day \n Christmas Day \n\nNOTE: Any of the above holidays falling on a Saturday will be observed on the preceding Friday; holidays falling on a Sunday will be observed on the following Monday. Any holidays that are declared by Presidential Executive Order shall be observed in the same manner as the holidays listed above. \n1.11.1 SERVICE REPORTS: A copy of the service report, complete with test data, will be furnished to the COR within 5 working days after completion of a PMI or Corrective Maintenance.\n1.12 CONTRACTOR PROVIDED SERVICES:\n1.12.1 The Contractor shall furnish all personnel and services to comply with the requirements of this contract.  The Contractor will report to Biomed to be escorted to the equipment.  The Contractor will converse with Biomed prior to exiting the building.  He/she will provide an update of the equipment status and what work was performed.\n1.12.2 POINT OF CONTACT: Upon award, the Contractor shall designate, in writing  and provide to the COR and Contracting Officer, the name and telephone number of the point of contact for all actions on this requirement.\n2.0 DEFINITIONS/ACRONYMS:\nCONTRACTING OFFICER (CO): A person with the authority to enter into, administer, and/or terminate contracts and make related determinations and findings on contracts.\nCONTRACTING OFFICER'S REPRESENTATIVE (COR): A Government employee, appointed in writing and within the limits of authority as delegated by the contracting officer, authorized to act as his representative in monitoring a contract.\nQUALITY ASSESSMENT AND IMPROVEMENT (QA&I): An ongoing program designed to objectively and systematically monitor and evaluate the quality and appropriateness of patient care, to pursue opportunities to improve patient care, and to resolve identified problems\nQUALITY CONTROL: Those actions taken by the Contractor to control and ensure that performance of duties meet the requirements of the contract.\n\n3.0        APPLICABLE TECHNICAL ORDERS, MANUALS, REGULATIONS, DIRECTIVES AND FORMS: All applicable directives and publications (advisory or mandatory), and supplements or amendments to these directives and publications will be current when furnished to the contractor. Directives will be available to contractor upon request.\n   \n3.1     The Contractor is required to follow all mandatory documents to the extent they apply to this contract. Any such changes to mandatory publications that cause a change in the scope of performance will not be implemented by the contractor until the Contracting Officer issues a modification in writing. \n\n3.2    All Test Equipment utilized must meet NIST and ISO 9001 standards.  Technicians must provide proof of calibration of instrumentation upon before or upon arrival.  All invoices must contain the model, serial number and calibration date/due of test equipment utilized.  The C&A Requirements do not apply and that a Security Accreditation Package is not required.","origin":"detail"},"contacts":[{"fax":"NONE","name":"AMY WALTER","role":"primary","email":"AMY.WALTER1@VA.GOV","phone":"NONE","title":"CONTRACTING OFFICER"}],"place_of_performance":null,"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"2b34174fb73840f7930afab8dffb8548","name":"department.va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-02-04T18:25:13.844Z","export_controlled":false,"sha256":null,"url":"https://department.va.gov/integrated-service-networks/visn-0","mirrored":false},{"resource_id":"2630c4d6f11e4b038fac5494690d62c4","name":"36C24526Q0190.docx","kind":"file","mime_type":".docx","size_bytes":34743,"posted_at":"2025-12-17T17:16:39.069Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2630c4d6f11e4b038fac5494690d62c4/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"PCANIDDK12835","latest_notice_id":"12bcdd2c0d4b431091cd615c8259722e","title":"Liquid Chromatography System","solicitation_number":"PCA-NIDDK-12835","notice_type":"p","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T17:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"H149","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"75N98027Q00103","latest_notice_id":"9f2a25be3d994d6f9e358554b7ce2c72","title":"Mechanical Preventative Maintenance","solicitation_number":"75N98027Q00103","notice_type":"p","first_type":"p","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T14:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"NOIOLAOCC27001340","latest_notice_id":"e546cb593aef4b4f8dc22f673ca293f2","title":"Intent to Sole Source - REES Scientific, Inc. installation of 5.0 GHz wireless temperature and humidity probes","solicitation_number":"NOI-OLAO-CC-27-001340","notice_type":"p","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T17:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"811210","psc":"J053","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":58,"indexable":false}