{"canonical":"https://sealedbidder.com/opportunities/36c24526q0081","key":"36C24526Q0081","url":"https://sealedbidder.com/opportunities/36c24526q0081","title":"J065--Annual Medical Gas Delivery Systems Testing and Inspection and Training (VA-26-00014193)","solicitation_number":"36C24526Q0081","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-03T04:00:00Z","first_posted":"2025-10-21","last_posted":"2025-10-21","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"333912","psc":"J065","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","title":"J065--Annual Medical Gas Delivery Systems Testing and Inspection and Training (VA-26-00014193)","solicitation_number":"36C24526Q0081","notice_type":"r","base_type":"r","posted":"2025-10-21","posted_at":"2025-10-21T18:58:52.112Z","due_at":"2025-11-03T04:00:00Z","due_date":"2025-11-02","cancelled":false,"archived":true,"archive_date":"2025-12-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8ad9c92b48b44effbdfa9aba8d2b15b3/view","enriched":true,"history":[{"index":3,"title":"J065--Annual Medical Gas Delivery Systems Testing and Inspection and Training (VA-26-00014193)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-21T18:58:52.112Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","solicitation_number":"36C24526Q0081"}]}],"latest_notice_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-10-21","posted_at":"2025-10-21T18:58:52.112Z","created_at":"2025-10-21T18:58:24.041Z","modified_at":"2025-12-02T05:04:36.841Z","response_deadline":{"raw":"2025-11-02T23:00:00-05:00","utc":"2025-11-03T04:00:00Z","date":"2025-11-02","time":"23:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8ad9c92b48b44effbdfa9aba8d2b15b3/view"},"naics":{"codes":["333912"],"primary":"333912"},"title":"J065--Annual Medical Gas Delivery Systems Testing and Inspection and Training (VA-26-00014193)","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-12-02","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--Annual Medical Gas Delivery Systems Testing and Inspection and Training (VA-26-00014193)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-21T18:58:52.112Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","solicitation_number":"36C24526Q0081"}],"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","phone":"410-637-1513","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","lineage_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-25T03:11:42.412764813Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"fc5c519f305c645ac39507b377892b9c37a73477fa609325634d549f71e51623","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-25T03:11:42.412764813Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"DISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\n\nSubmit Capability Statement to Keysha.Gorman74@va.gov by 11/2/2025 by 11pm.  Include type of business size and SAM s   identification number. \nPage 7 of 7\n\nPage 7 of 7\nSTATEMENT OF WORK\n\nTITLE: Annual Medical Gas Delivery Systems Testing and Inspection and Training\n\n\nI. SCOPE OF WORK\nThis Scope of Work encompasses the following 3 Task Items:\n\nCLIN - (Contractor Line Item Number) #1   Instructor Led VAMC Staff Training Courses.\nThe contractor shall supply materials and an instructor to provide 3x 32-hour training class for ASSE 6040 Medical Gas System Maintenance for Staff personnel certification of VAMC employees. The instructor is required to have a minimum of 10 years  experience in design, testing, verification, and troubleshooting of medical gas systems and a currently be credentialed an ASSE 6050 Instructor. The number of students (VA employees) for the class is not to exceed 16. The Training will need to be coordinated with the COR. The training will need to take place between October 2025 and February 2026 at least once at each site withing the Maryland Health Care System. Sites include those listed under Task Item #2, (Baltimore, Loch Raven, Perry Point.)\n\nCLIN - (Contractor Line Item Number) #2   Medical Air, Vacuum, and HVAC Compressor equipment testing, verification, and certification.\n\nThe Contractor shall provide a certified ASSE 6030 Medical Gas Verifier(s), testing equipment, supplies and transportation. All work is to be completed within 120 calendar days from the award date. Contractor to submit a work schedule for each site for the COR for approval. The contractor will perform the inspection and testing of the medical gas delivery systems for the Department of Veterans Affairs, VA\nMaryland Health Care System at these three locations:\n1. Baltimore VA Medical Center\n10 North Greene St.\nBaltimore, MD 21201\n\n2. Loch Raven Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n\n3. Perry Point VA Medical Center\nPerry Point, MD 21902-1000\n\nII. MEDICAL GAS SYSTEMS FOR EACH SITE\nA. Baltimore VA Medical Center\n10 North Greene St,\nBaltimore, MD 21201\n1. Master alarm panels (3 ea.)\n2. Master Alarm Signals (54 ea.)\n3. Area Alarm Panel (19 ea.)\n4. Alarm Signals (68 ea.)\n5. Zone Value Boxes (36 ea.)\n6. Zone Values (126 ea.)\n7. Outlets (1,462 ea.) O2, MA, N2O, N2, VAC, WAGD\n8. Bulk O2 with reserve tank, supplier/owner Air Products\n9. Medical Air System 7th floor (3 ea.) 15-hp oil-less compressors\n10. Dental Air System, room 1D-166, POWEREX (460v/3ph)\n11. Dental Vacuum System, room 1D-166, ECO VAC, duplex 7.5hp\n12. Dental Nitrogen manifold system (2 ea.) left side and (2 ea.) right side\n13. Medical Vacuum System 7th floor (3 ea.) 15-hp oil-lubed rotary\n14. Nitrogen manifold system (8 ea.) bottles left side and (8 ea.) bottles right\nside\n15. Nitrous oxide manifold system (8 ea.) bottles left side and (8 ea.) bottles right side\nB. Loch Raven VA Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n1. Master alarm panels (2 ea.)\n2. Master Alarm Signals (24 ea.)\n3. Area Alarm Panel (4 ea.)\n4. Alarm Signals (12 ea.)\n5. Zone Value Boxes (4 ea.)\n6. Zone Values (12 ea.)\n7. Outlets (240 ea.) O2, MA, VAC\n8. Bulk O2 with reserve bottles, supplier/owner Air Products\n9. Medical Air System duplex 5-hp oil-less compressors\n10. Medical Vacuum System (2 ea.) 5-hp oil-lubed rotary\n\nC. Perry Point VA Medical Center\nPerry Point, MD 21902\n1. Master alarm panels (total: 6 ea.)\na. Building 23H (2 ea.)\nb. Building 19H (1 ea.) (NOTE: BLDG. Under Construction/ Subject to Change.)\nc. Building 14H (2 ea.)\nd. Building 361 (1 ea.)\n2. Master Alarm Signals (98 ea.)\n3. Area Alarm Panel (10 ea.)\n4. Alarm Signals (98 ea.)\n5. Zone Value Boxes (26 ea.)\n6. Zone Values (70 ea.)\n7. Outlets (263 ea.) O2, MA, VAC\n8. Bulk O2 & reserve tank location 14H supplier/owner is Airgas (Air Liquide)\n9. Bulk O2 & reserve tank location 19H supplier/owner is Airgas (Air Liquide)\n10. Medical Air System location 14H, duplex 5-hp oil-less compressors\n11. Medical Air System location 23H, duplex 5-hp oil-less compressors\n12. Medical Vacuum System location 14H ,duplex 5-hp oil-lubed rotary\n13. Medical Vacuum System location 23H ,duplex 5-hp oil-lubed rotary\n14. Medical Vacuum System location 19H ,duplex 5-hp oil-lubed rotary\n15. Medical Vacuum System location 24H ,duplex 1-hp oil-lubed rotary\n (NOTE: BLDG. 24H Subject to Possible Demolition in Future.)\n16. Dental Air and Dental Vacuum\n\nIII. SPECIFICATIONS:\nThe Contractor shall inspect and certify the medical gas delivery systems at each\nsite in accordance with most recent NFPA-99 Health Care Facilities, NFPA-55\nCompressed Gases and Cryogenic Fluids, and NFPA-70 National Electrical Code.\n\nTesting Master Alarm Panels\nFunction test of all signals from source and bulk systems to master alarm panels.\nSimulate failures at all source field switches. Includes determination of trip setting\naccuracy and correct bulk/source system labeling.\n\nTesting Area Alarm Panels\nTests all audible and visual alarm signals for continuity, determine accuracy of trip\nsettings and readouts. Includes determination of proper area served signage.\nPressure transducers/pressure switches will be function tested to determine proper\noperation of hi/lo pressure signals, proper communication with area panel, and\ndetermination of hi/lo trip setting on alarm display.\n\nZone valves\nVerify proper area served labeling, test for external leakage and validate accuracy of\npressure gauge. Particulate samples are taken in each zone to test for contamination.\n\nBulk Oxygen Supply Systems\nTest operation of the reserve and reserve in use signaling devices, check proper\nfunction of level activating switch. Inspect all cryogenic tanks for security, leaks,\ncontrol configuration and labeling. Inspect Emergency Oxygen Supply Connection\n(EOSC).\n\nGas Manifold Source Systems\nLeak test all manifold components including valves, pigtails, and regulators. Test for\nproper reserve in use pressure switch activation. Test for proper operation of the\nchangeover for secondary supply.\n\nMedical Air System\nVerify compressor operating within manufacturer specifications. Check for\ndocumented maintenance plan in place. Function test of automatic alternating\ncontrols. Test audible and visual alarms. Test pressure across filters. Calibrate dew\npoint monitor and verify proper operation.\n\nMedical Vacuum System\nVerify maintenance conducted according to manufacturer specifications. Function\ntest automatic alternating controls. Test pressure/vacuum switch for proper operation.\nValidate frequency of pump starts and duration of runs. Measure cut-in and cut-out\npressure/vacuum.\n\nMedical Gas Outlets\nVacuum inlets and pressure gas outlets. Test flow of all vacuum inlets. Check\npressure and flow of all outlets: patient care areas, emergency rooms, intensive care,\nprocedure labs, operating rooms and recovery rooms. The surgical rooms testing is\nperformed after-hours. This testing includes coordination with the Baltimore site POC.\n\nManufactured Assemblies\nVerify that each joint and DISS fitting is examined for leakage and that the flexible\nassemblies are in a safe working condition.\n\nCLIN - (Contractor Line Item Number) #3   Preventative Maintenance\n \n Service Requirements:\n \nFrequency: Two (2) preventative maintenance service visits per year and provide a detailed inspection report to the COR within 7 days after the inspections.\n\nComprehensive Inspection: During each visit, all equipment, including air compressors, vacuum systems, and associated accessories (filters, dryers, monitors, etc.), shall be thoroughly inspected, regardless of whether maintenance is immediately required.\n\nManufacturer Guidelines: All maintenance shall be performed in strict accordance with the equipment manufacturers' guidelines and recommended service intervals based on run-time hours.\n\nSpecific Service Tasks: The following tasks shall be performed, as applicable, for each piece of equipment:\n\nReplace air intake filters.\nReplace exhaust filter elements.\nClean aftercoolers and line filters.\nInspect Air Treatment Centers for proper operation.\nAlternate Desiccant Dryers.\nCalibrate CO monitors (where applicable).\nCheck DP monitors.\nCheck and adjust controls for proper operation.\nCheck motor, starter contacts, voltage, amp draw, control wiring, and \nbelts.\nDrain and replace lubricants, including visual inspection for water and contamination.\nRegrease components as needed.\nPerform a general visual inspection of all components.\nPerform a basic wipe-down of units.\nDocument all findings and submit a detailed service report.\nJoint Commission Compliance: All service reports shall comply with Joint Commission standards for preventative maintenance documentation.\nEquipment Tagging: All serviced units shall be tagged upon completion of maintenance.\nNormal Business Hours: All work shall be conducted during normal business hours.\nScheduling: A strict schedule shall be developed and adhered to, ensuring maintenance is performed within the month scheduled to maintain Joint Commission compliance. Schedule shall be submitted to the COR 2 Weeks in advance of normal work start. \nEmergency visits shall be exempted from the schedule requirements and may require off hour availability. Responding technicians are required to report on site within a 4 hour period from service call initiation.\n\n\n        END OF SCOPE OF WORK SECTION","text":"DISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nSubmit Capability Statement to Keysha.Gorman74@va.gov by 11/2/2025 by 11pm. Include type of business size and SAM s identification number.\nPage 7 of 7\n\nPage 7 of 7\nSTATEMENT OF WORK\n\nTITLE: Annual Medical Gas Delivery Systems Testing and Inspection and Training\n\nI. SCOPE OF WORK\nThis Scope of Work encompasses the following 3 Task Items:\n\nCLIN - (Contractor Line Item Number) #1 Instructor Led VAMC Staff Training Courses.\nThe contractor shall supply materials and an instructor to provide 3x 32-hour training class for ASSE 6040 Medical Gas System Maintenance for Staff personnel certification of VAMC employees. The instructor is required to have a minimum of 10 years experience in design, testing, verification, and troubleshooting of medical gas systems and a currently be credentialed an ASSE 6050 Instructor. The number of students (VA employees) for the class is not to exceed 16. The Training will need to be coordinated with the COR. The training will need to take place between October 2025 and February 2026 at least once at each site withing the Maryland Health Care System. Sites include those listed under Task Item #2, (Baltimore, Loch Raven, Perry Point.)\n\nCLIN - (Contractor Line Item Number) #2 Medical Air, Vacuum, and HVAC Compressor equipment testing, verification, and certification.\n\nThe Contractor shall provide a certified ASSE 6030 Medical Gas Verifier(s), testing equipment, supplies and transportation. All work is to be completed within 120 calendar days from the award date. Contractor to submit a work schedule for each site for the COR for approval. The contractor will perform the inspection and testing of the medical gas delivery systems for the Department of Veterans Affairs, VA\nMaryland Health Care System at these three locations:\n1. Baltimore VA Medical Center\n10 North Greene St.\nBaltimore, MD 21201\n\n2. Loch Raven Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n\n3. Perry Point VA Medical Center\nPerry Point, MD 21902-1000\n\nII. MEDICAL GAS SYSTEMS FOR EACH SITE\nA. Baltimore VA Medical Center\n10 North Greene St,\nBaltimore, MD 21201\n1. Master alarm panels (3 ea.)\n2. Master Alarm Signals (54 ea.)\n3. Area Alarm Panel (19 ea.)\n4. Alarm Signals (68 ea.)\n5. Zone Value Boxes (36 ea.)\n6. Zone Values (126 ea.)\n7. Outlets (1,462 ea.) O2, MA, N2O, N2, VAC, WAGD\n8. Bulk O2 with reserve tank, supplier/owner Air Products\n9. Medical Air System 7th floor (3 ea.) 15-hp oil-less compressors\n10. Dental Air System, room 1D-166, POWEREX (460v/3ph)\n11. Dental Vacuum System, room 1D-166, ECO VAC, duplex 7.5hp\n12. Dental Nitrogen manifold system (2 ea.) left side and (2 ea.) right side\n13. Medical Vacuum System 7th floor (3 ea.) 15-hp oil-lubed rotary\n14. Nitrogen manifold system (8 ea.) bottles left side and (8 ea.) bottles right\nside\n15. Nitrous oxide manifold system (8 ea.) bottles left side and (8 ea.) bottles right side\nB. Loch Raven VA Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n1. Master alarm panels (2 ea.)\n2. Master Alarm Signals (24 ea.)\n3. Area Alarm Panel (4 ea.)\n4. Alarm Signals (12 ea.)\n5. Zone Value Boxes (4 ea.)\n6. Zone Values (12 ea.)\n7. Outlets (240 ea.) O2, MA, VAC\n8. Bulk O2 with reserve bottles, supplier/owner Air Products\n9. Medical Air System duplex 5-hp oil-less compressors\n10. Medical Vacuum System (2 ea.) 5-hp oil-lubed rotary\n\nC. Perry Point VA Medical Center\nPerry Point, MD 21902\n1. Master alarm panels (total: 6 ea.)\na. Building 23H (2 ea.)\nb. Building 19H (1 ea.) (NOTE: BLDG. Under Construction/ Subject to Change.)\nc. Building 14H (2 ea.)\nd. Building 361 (1 ea.)\n2. Master Alarm Signals (98 ea.)\n3. Area Alarm Panel (10 ea.)\n4. Alarm Signals (98 ea.)\n5. Zone Value Boxes (26 ea.)\n6. Zone Values (70 ea.)\n7. Outlets (263 ea.) O2, MA, VAC\n8. Bulk O2 & reserve tank location 14H supplier/owner is Airgas (Air Liquide)\n9. Bulk O2 & reserve tank location 19H supplier/owner is Airgas (Air Liquide)\n10. Medical Air System location 14H, duplex 5-hp oil-less compressors\n11. Medical Air System location 23H, duplex 5-hp oil-less compressors\n12. Medical Vacuum System location 14H ,duplex 5-hp oil-lubed rotary\n13. Medical Vacuum System location 23H ,duplex 5-hp oil-lubed rotary\n14. Medical Vacuum System location 19H ,duplex 5-hp oil-lubed rotary\n15. Medical Vacuum System location 24H ,duplex 1-hp oil-lubed rotary\n(NOTE: BLDG. 24H Subject to Possible Demolition in Future.)\n16. Dental Air and Dental Vacuum\n\nIII. SPECIFICATIONS:\nThe Contractor shall inspect and certify the medical gas delivery systems at each\nsite in accordance with most recent NFPA-99 Health Care Facilities, NFPA-55\nCompressed Gases and Cryogenic Fluids, and NFPA-70 National Electrical Code.\n\nTesting Master Alarm Panels\nFunction test of all signals from source and bulk systems to master alarm panels.\nSimulate failures at all source field switches. Includes determination of trip setting\naccuracy and correct bulk/source system labeling.\n\nTesting Area Alarm Panels\nTests all audible and visual alarm signals for continuity, determine accuracy of trip\nsettings and readouts. Includes determination of proper area served signage.\nPressure transducers/pressure switches will be function tested to determine proper\noperation of hi/lo pressure signals, proper communication with area panel, and\ndetermination of hi/lo trip setting on alarm display.\n\nZone valves\nVerify proper area served labeling, test for external leakage and validate accuracy of\npressure gauge. Particulate samples are taken in each zone to test for contamination.\n\nBulk Oxygen Supply Systems\nTest operation of the reserve and reserve in use signaling devices, check proper\nfunction of level activating switch. Inspect all cryogenic tanks for security, leaks,\ncontrol configuration and labeling. Inspect Emergency Oxygen Supply Connection\n(EOSC).\n\nGas Manifold Source Systems\nLeak test all manifold components including valves, pigtails, and regulators. Test for\nproper reserve in use pressure switch activation. Test for proper operation of the\nchangeover for secondary supply.\n\nMedical Air System\nVerify compressor operating within manufacturer specifications. Check for\ndocumented maintenance plan in place. Function test of automatic alternating\ncontrols. Test audible and visual alarms. Test pressure across filters. Calibrate dew\npoint monitor and verify proper operation.\n\nMedical Vacuum System\nVerify maintenance conducted according to manufacturer specifications. Function\ntest automatic alternating controls. Test pressure/vacuum switch for proper operation.\nValidate frequency of pump starts and duration of runs. Measure cut-in and cut-out\npressure/vacuum.\n\nMedical Gas Outlets\nVacuum inlets and pressure gas outlets. Test flow of all vacuum inlets. Check\npressure and flow of all outlets: patient care areas, emergency rooms, intensive care,\nprocedure labs, operating rooms and recovery rooms. The surgical rooms testing is\nperformed after-hours. This testing includes coordination with the Baltimore site POC.\n\nManufactured Assemblies\nVerify that each joint and DISS fitting is examined for leakage and that the flexible\nassemblies are in a safe working condition.\n\nCLIN - (Contractor Line Item Number) #3 Preventative Maintenance\n\nService Requirements:\n\nFrequency: Two (2) preventative maintenance service visits per year and provide a detailed inspection report to the COR within 7 days after the inspections.\n\nComprehensive Inspection: During each visit, all equipment, including air compressors, vacuum systems, and associated accessories (filters, dryers, monitors, etc.), shall be thoroughly inspected, regardless of whether maintenance is immediately required.\n\nManufacturer Guidelines: All maintenance shall be performed in strict accordance with the equipment manufacturers' guidelines and recommended service intervals based on run-time hours.\n\nSpecific Service Tasks: The following tasks shall be performed, as applicable, for each piece of equipment:\n\nReplace air intake filters.\nReplace exhaust filter elements.\nClean aftercoolers and line filters.\nInspect Air Treatment Centers for proper operation.\nAlternate Desiccant Dryers.\nCalibrate CO monitors (where applicable).\nCheck DP monitors.\nCheck and adjust controls for proper operation.\nCheck motor, starter contacts, voltage, amp draw, control wiring, and\nbelts.\nDrain and replace lubricants, including visual inspection for water and contamination.\nRegrease components as needed.\nPerform a general visual inspection of all components.\nPerform a basic wipe-down of units.\nDocument all findings and submit a detailed service report.\nJoint Commission Compliance: All service reports shall comply with Joint Commission standards for preventative maintenance documentation.\nEquipment Tagging: All serviced units shall be tagged upon completion of maintenance.\nNormal Business Hours: All work shall be conducted during normal business hours.\nScheduling: A strict schedule shall be developed and adhered to, ensuring maintenance is performed within the month scheduled to maintain Joint Commission compliance. Schedule shall be submitted to the COR 2 Weeks in advance of normal work start.\nEmergency visits shall be exempted from the schedule requirements and may require off hour availability. Responding technicians are required to report on site within a 4 hour period from service call initiation.\n\nEND OF SCOPE OF WORK SECTION","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0081","place_of_performance":{"zip":"21201","city":{"name":"Baltimore"},"state":{"name":"MD"},"street":"Department of Veterans Affairs VAMC","street2":"10 N Greene St"},"product_service_code":"J065"}],"due_at":"2025-11-03T04:00:00Z","due_date":"2025-11-02","closes_at":"2025-11-03T04:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-25T03:55:02.956276Z","principal_notice_id":"8ad9c92b48b44effbdfa9aba8d2b15b3","description":{"text":"DISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\n\nSubmit Capability Statement to Keysha.Gorman74@va.gov by 11/2/2025 by 11pm. Include type of business size and SAM s identification number.\nPage 7 of 7\n\nPage 7 of 7\nSTATEMENT OF WORK\n\nTITLE: Annual Medical Gas Delivery Systems Testing and Inspection and Training\n\nI. SCOPE OF WORK\nThis Scope of Work encompasses the following 3 Task Items:\n\nCLIN - (Contractor Line Item Number) #1 Instructor Led VAMC Staff Training Courses.\nThe contractor shall supply materials and an instructor to provide 3x 32-hour training class for ASSE 6040 Medical Gas System Maintenance for Staff personnel certification of VAMC employees. The instructor is required to have a minimum of 10 years experience in design, testing, verification, and troubleshooting of medical gas systems and a currently be credentialed an ASSE 6050 Instructor. The number of students (VA employees) for the class is not to exceed 16. The Training will need to be coordinated with the COR. The training will need to take place between October 2025 and February 2026 at least once at each site withing the Maryland Health Care System. Sites include those listed under Task Item #2, (Baltimore, Loch Raven, Perry Point.)\n\nCLIN - (Contractor Line Item Number) #2 Medical Air, Vacuum, and HVAC Compressor equipment testing, verification, and certification.\n\nThe Contractor shall provide a certified ASSE 6030 Medical Gas Verifier(s), testing equipment, supplies and transportation. All work is to be completed within 120 calendar days from the award date. Contractor to submit a work schedule for each site for the COR for approval. The contractor will perform the inspection and testing of the medical gas delivery systems for the Department of Veterans Affairs, VA\nMaryland Health Care System at these three locations:\n1. Baltimore VA Medical Center\n10 North Greene St.\nBaltimore, MD 21201\n\n2. Loch Raven Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n\n3. Perry Point VA Medical Center\nPerry Point, MD 21902-1000\n\nII. MEDICAL GAS SYSTEMS FOR EACH SITE\nA. Baltimore VA Medical Center\n10 North Greene St,\nBaltimore, MD 21201\n1. Master alarm panels (3 ea.)\n2. Master Alarm Signals (54 ea.)\n3. Area Alarm Panel (19 ea.)\n4. Alarm Signals (68 ea.)\n5. Zone Value Boxes (36 ea.)\n6. Zone Values (126 ea.)\n7. Outlets (1,462 ea.) O2, MA, N2O, N2, VAC, WAGD\n8. Bulk O2 with reserve tank, supplier/owner Air Products\n9. Medical Air System 7th floor (3 ea.) 15-hp oil-less compressors\n10. Dental Air System, room 1D-166, POWEREX (460v/3ph)\n11. Dental Vacuum System, room 1D-166, ECO VAC, duplex 7.5hp\n12. Dental Nitrogen manifold system (2 ea.) left side and (2 ea.) right side\n13. Medical Vacuum System 7th floor (3 ea.) 15-hp oil-lubed rotary\n14. Nitrogen manifold system (8 ea.) bottles left side and (8 ea.) bottles right\nside\n15. Nitrous oxide manifold system (8 ea.) bottles left side and (8 ea.) bottles right side\nB. Loch Raven VA Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n1. Master alarm panels (2 ea.)\n2. Master Alarm Signals (24 ea.)\n3. Area Alarm Panel (4 ea.)\n4. Alarm Signals (12 ea.)\n5. Zone Value Boxes (4 ea.)\n6. Zone Values (12 ea.)\n7. Outlets (240 ea.) O2, MA, VAC\n8. Bulk O2 with reserve bottles, supplier/owner Air Products\n9. Medical Air System duplex 5-hp oil-less compressors\n10. Medical Vacuum System (2 ea.) 5-hp oil-lubed rotary\n\nC. Perry Point VA Medical Center\nPerry Point, MD 21902\n1. Master alarm panels (total: 6 ea.)\na. Building 23H (2 ea.)\nb. Building 19H (1 ea.) (NOTE: BLDG. Under Construction/ Subject to Change.)\nc. Building 14H (2 ea.)\nd. Building 361 (1 ea.)\n2. Master Alarm Signals (98 ea.)\n3. Area Alarm Panel (10 ea.)\n4. Alarm Signals (98 ea.)\n5. Zone Value Boxes (26 ea.)\n6. Zone Values (70 ea.)\n7. Outlets (263 ea.) O2, MA, VAC\n8. Bulk O2 & reserve tank location 14H supplier/owner is Airgas (Air Liquide)\n9. Bulk O2 & reserve tank location 19H supplier/owner is Airgas (Air Liquide)\n10. Medical Air System location 14H, duplex 5-hp oil-less compressors\n11. Medical Air System location 23H, duplex 5-hp oil-less compressors\n12. Medical Vacuum System location 14H ,duplex 5-hp oil-lubed rotary\n13. Medical Vacuum System location 23H ,duplex 5-hp oil-lubed rotary\n14. Medical Vacuum System location 19H ,duplex 5-hp oil-lubed rotary\n15. Medical Vacuum System location 24H ,duplex 1-hp oil-lubed rotary\n(NOTE: BLDG. 24H Subject to Possible Demolition in Future.)\n16. Dental Air and Dental Vacuum\n\nIII. SPECIFICATIONS:\nThe Contractor shall inspect and certify the medical gas delivery systems at each\nsite in accordance with most recent NFPA-99 Health Care Facilities, NFPA-55\nCompressed Gases and Cryogenic Fluids, and NFPA-70 National Electrical Code.\n\nTesting Master Alarm Panels\nFunction test of all signals from source and bulk systems to master alarm panels.\nSimulate failures at all source field switches. Includes determination of trip setting\naccuracy and correct bulk/source system labeling.\n\nTesting Area Alarm Panels\nTests all audible and visual alarm signals for continuity, determine accuracy of trip\nsettings and readouts. Includes determination of proper area served signage.\nPressure transducers/pressure switches will be function tested to determine proper\noperation of hi/lo pressure signals, proper communication with area panel, and\ndetermination of hi/lo trip setting on alarm display.\n\nZone valves\nVerify proper area served labeling, test for external leakage and validate accuracy of\npressure gauge. Particulate samples are taken in each zone to test for contamination.\n\nBulk Oxygen Supply Systems\nTest operation of the reserve and reserve in use signaling devices, check proper\nfunction of level activating switch. Inspect all cryogenic tanks for security, leaks,\ncontrol configuration and labeling. Inspect Emergency Oxygen Supply Connection\n(EOSC).\n\nGas Manifold Source Systems\nLeak test all manifold components including valves, pigtails, and regulators. Test for\nproper reserve in use pressure switch activation. Test for proper operation of the\nchangeover for secondary supply.\n\nMedical Air System\nVerify compressor operating within manufacturer specifications. Check for\ndocumented maintenance plan in place. Function test of automatic alternating\ncontrols. Test audible and visual alarms. Test pressure across filters. Calibrate dew\npoint monitor and verify proper operation.\n\nMedical Vacuum System\nVerify maintenance conducted according to manufacturer specifications. Function\ntest automatic alternating controls. Test pressure/vacuum switch for proper operation.\nValidate frequency of pump starts and duration of runs. Measure cut-in and cut-out\npressure/vacuum.\n\nMedical Gas Outlets\nVacuum inlets and pressure gas outlets. Test flow of all vacuum inlets. Check\npressure and flow of all outlets: patient care areas, emergency rooms, intensive care,\nprocedure labs, operating rooms and recovery rooms. The surgical rooms testing is\nperformed after-hours. This testing includes coordination with the Baltimore site POC.\n\nManufactured Assemblies\nVerify that each joint and DISS fitting is examined for leakage and that the flexible\nassemblies are in a safe working condition.\n\nCLIN - (Contractor Line Item Number) #3 Preventative Maintenance\n\nService Requirements:\n\nFrequency: Two (2) preventative maintenance service visits per year and provide a detailed inspection report to the COR within 7 days after the inspections.\n\nComprehensive Inspection: During each visit, all equipment, including air compressors, vacuum systems, and associated accessories (filters, dryers, monitors, etc.), shall be thoroughly inspected, regardless of whether maintenance is immediately required.\n\nManufacturer Guidelines: All maintenance shall be performed in strict accordance with the equipment manufacturers' guidelines and recommended service intervals based on run-time hours.\n\nSpecific Service Tasks: The following tasks shall be performed, as applicable, for each piece of equipment:\n\nReplace air intake filters.\nReplace exhaust filter elements.\nClean aftercoolers and line filters.\nInspect Air Treatment Centers for proper operation.\nAlternate Desiccant Dryers.\nCalibrate CO monitors (where applicable).\nCheck DP monitors.\nCheck and adjust controls for proper operation.\nCheck motor, starter contacts, voltage, amp draw, control wiring, and\nbelts.\nDrain and replace lubricants, including visual inspection for water and contamination.\nRegrease components as needed.\nPerform a general visual inspection of all components.\nPerform a basic wipe-down of units.\nDocument all findings and submit a detailed service report.\nJoint Commission Compliance: All service reports shall comply with Joint Commission standards for preventative maintenance documentation.\nEquipment Tagging: All serviced units shall be tagged upon completion of maintenance.\nNormal Business Hours: All work shall be conducted during normal business hours.\nScheduling: A strict schedule shall be developed and adhered to, ensuring maintenance is performed within the month scheduled to maintain Joint Commission compliance. Schedule shall be submitted to the COR 2 Weeks in advance of normal work start.\nEmergency visits shall be exempted from the schedule requirements and may require off hour availability. Responding technicians are required to report on site within a 4 hour period from service call initiation.\n\nEND OF SCOPE OF WORK SECTION","html":"DISCLAIMER\n  This RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\n\nSubmit Capability Statement to Keysha.Gorman74@va.gov by 11/2/2025 by 11pm.  Include type of business size and SAM s   identification number. \nPage 7 of 7\n\nPage 7 of 7\nSTATEMENT OF WORK\n\nTITLE: Annual Medical Gas Delivery Systems Testing and Inspection and Training\n\n\nI. SCOPE OF WORK\nThis Scope of Work encompasses the following 3 Task Items:\n\nCLIN - (Contractor Line Item Number) #1   Instructor Led VAMC Staff Training Courses.\nThe contractor shall supply materials and an instructor to provide 3x 32-hour training class for ASSE 6040 Medical Gas System Maintenance for Staff personnel certification of VAMC employees. The instructor is required to have a minimum of 10 years  experience in design, testing, verification, and troubleshooting of medical gas systems and a currently be credentialed an ASSE 6050 Instructor. The number of students (VA employees) for the class is not to exceed 16. The Training will need to be coordinated with the COR. The training will need to take place between October 2025 and February 2026 at least once at each site withing the Maryland Health Care System. Sites include those listed under Task Item #2, (Baltimore, Loch Raven, Perry Point.)\n\nCLIN - (Contractor Line Item Number) #2   Medical Air, Vacuum, and HVAC Compressor equipment testing, verification, and certification.\n\nThe Contractor shall provide a certified ASSE 6030 Medical Gas Verifier(s), testing equipment, supplies and transportation. All work is to be completed within 120 calendar days from the award date. Contractor to submit a work schedule for each site for the COR for approval. The contractor will perform the inspection and testing of the medical gas delivery systems for the Department of Veterans Affairs, VA\nMaryland Health Care System at these three locations:\n1. Baltimore VA Medical Center\n10 North Greene St.\nBaltimore, MD 21201\n\n2. Loch Raven Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n\n3. Perry Point VA Medical Center\nPerry Point, MD 21902-1000\n\nII. MEDICAL GAS SYSTEMS FOR EACH SITE\nA. Baltimore VA Medical Center\n10 North Greene St,\nBaltimore, MD 21201\n1. Master alarm panels (3 ea.)\n2. Master Alarm Signals (54 ea.)\n3. Area Alarm Panel (19 ea.)\n4. Alarm Signals (68 ea.)\n5. Zone Value Boxes (36 ea.)\n6. Zone Values (126 ea.)\n7. Outlets (1,462 ea.) O2, MA, N2O, N2, VAC, WAGD\n8. Bulk O2 with reserve tank, supplier/owner Air Products\n9. Medical Air System 7th floor (3 ea.) 15-hp oil-less compressors\n10. Dental Air System, room 1D-166, POWEREX (460v/3ph)\n11. Dental Vacuum System, room 1D-166, ECO VAC, duplex 7.5hp\n12. Dental Nitrogen manifold system (2 ea.) left side and (2 ea.) right side\n13. Medical Vacuum System 7th floor (3 ea.) 15-hp oil-lubed rotary\n14. Nitrogen manifold system (8 ea.) bottles left side and (8 ea.) bottles right\nside\n15. Nitrous oxide manifold system (8 ea.) bottles left side and (8 ea.) bottles right side\nB. Loch Raven VA Medical Center\n3900 Loch Raven Blvd\nBaltimore, MD 21228\n1. Master alarm panels (2 ea.)\n2. Master Alarm Signals (24 ea.)\n3. Area Alarm Panel (4 ea.)\n4. Alarm Signals (12 ea.)\n5. Zone Value Boxes (4 ea.)\n6. Zone Values (12 ea.)\n7. Outlets (240 ea.) O2, MA, VAC\n8. Bulk O2 with reserve bottles, supplier/owner Air Products\n9. Medical Air System duplex 5-hp oil-less compressors\n10. Medical Vacuum System (2 ea.) 5-hp oil-lubed rotary\n\nC. Perry Point VA Medical Center\nPerry Point, MD 21902\n1. Master alarm panels (total: 6 ea.)\na. Building 23H (2 ea.)\nb. Building 19H (1 ea.) (NOTE: BLDG. Under Construction/ Subject to Change.)\nc. Building 14H (2 ea.)\nd. Building 361 (1 ea.)\n2. Master Alarm Signals (98 ea.)\n3. Area Alarm Panel (10 ea.)\n4. Alarm Signals (98 ea.)\n5. Zone Value Boxes (26 ea.)\n6. Zone Values (70 ea.)\n7. Outlets (263 ea.) O2, MA, VAC\n8. Bulk O2 & reserve tank location 14H supplier/owner is Airgas (Air Liquide)\n9. Bulk O2 & reserve tank location 19H supplier/owner is Airgas (Air Liquide)\n10. Medical Air System location 14H, duplex 5-hp oil-less compressors\n11. Medical Air System location 23H, duplex 5-hp oil-less compressors\n12. Medical Vacuum System location 14H ,duplex 5-hp oil-lubed rotary\n13. Medical Vacuum System location 23H ,duplex 5-hp oil-lubed rotary\n14. Medical Vacuum System location 19H ,duplex 5-hp oil-lubed rotary\n15. Medical Vacuum System location 24H ,duplex 1-hp oil-lubed rotary\n (NOTE: BLDG. 24H Subject to Possible Demolition in Future.)\n16. Dental Air and Dental Vacuum\n\nIII. SPECIFICATIONS:\nThe Contractor shall inspect and certify the medical gas delivery systems at each\nsite in accordance with most recent NFPA-99 Health Care Facilities, NFPA-55\nCompressed Gases and Cryogenic Fluids, and NFPA-70 National Electrical Code.\n\nTesting Master Alarm Panels\nFunction test of all signals from source and bulk systems to master alarm panels.\nSimulate failures at all source field switches. Includes determination of trip setting\naccuracy and correct bulk/source system labeling.\n\nTesting Area Alarm Panels\nTests all audible and visual alarm signals for continuity, determine accuracy of trip\nsettings and readouts. Includes determination of proper area served signage.\nPressure transducers/pressure switches will be function tested to determine proper\noperation of hi/lo pressure signals, proper communication with area panel, and\ndetermination of hi/lo trip setting on alarm display.\n\nZone valves\nVerify proper area served labeling, test for external leakage and validate accuracy of\npressure gauge. Particulate samples are taken in each zone to test for contamination.\n\nBulk Oxygen Supply Systems\nTest operation of the reserve and reserve in use signaling devices, check proper\nfunction of level activating switch. Inspect all cryogenic tanks for security, leaks,\ncontrol configuration and labeling. Inspect Emergency Oxygen Supply Connection\n(EOSC).\n\nGas Manifold Source Systems\nLeak test all manifold components including valves, pigtails, and regulators. Test for\nproper reserve in use pressure switch activation. Test for proper operation of the\nchangeover for secondary supply.\n\nMedical Air System\nVerify compressor operating within manufacturer specifications. Check for\ndocumented maintenance plan in place. Function test of automatic alternating\ncontrols. Test audible and visual alarms. Test pressure across filters. Calibrate dew\npoint monitor and verify proper operation.\n\nMedical Vacuum System\nVerify maintenance conducted according to manufacturer specifications. Function\ntest automatic alternating controls. Test pressure/vacuum switch for proper operation.\nValidate frequency of pump starts and duration of runs. Measure cut-in and cut-out\npressure/vacuum.\n\nMedical Gas Outlets\nVacuum inlets and pressure gas outlets. Test flow of all vacuum inlets. Check\npressure and flow of all outlets: patient care areas, emergency rooms, intensive care,\nprocedure labs, operating rooms and recovery rooms. The surgical rooms testing is\nperformed after-hours. This testing includes coordination with the Baltimore site POC.\n\nManufactured Assemblies\nVerify that each joint and DISS fitting is examined for leakage and that the flexible\nassemblies are in a safe working condition.\n\nCLIN - (Contractor Line Item Number) #3   Preventative Maintenance\n \n Service Requirements:\n \nFrequency: Two (2) preventative maintenance service visits per year and provide a detailed inspection report to the COR within 7 days after the inspections.\n\nComprehensive Inspection: During each visit, all equipment, including air compressors, vacuum systems, and associated accessories (filters, dryers, monitors, etc.), shall be thoroughly inspected, regardless of whether maintenance is immediately required.\n\nManufacturer Guidelines: All maintenance shall be performed in strict accordance with the equipment manufacturers' guidelines and recommended service intervals based on run-time hours.\n\nSpecific Service Tasks: The following tasks shall be performed, as applicable, for each piece of equipment:\n\nReplace air intake filters.\nReplace exhaust filter elements.\nClean aftercoolers and line filters.\nInspect Air Treatment Centers for proper operation.\nAlternate Desiccant Dryers.\nCalibrate CO monitors (where applicable).\nCheck DP monitors.\nCheck and adjust controls for proper operation.\nCheck motor, starter contacts, voltage, amp draw, control wiring, and \nbelts.\nDrain and replace lubricants, including visual inspection for water and contamination.\nRegrease components as needed.\nPerform a general visual inspection of all components.\nPerform a basic wipe-down of units.\nDocument all findings and submit a detailed service report.\nJoint Commission Compliance: All service reports shall comply with Joint Commission standards for preventative maintenance documentation.\nEquipment Tagging: All serviced units shall be tagged upon completion of maintenance.\nNormal Business Hours: All work shall be conducted during normal business hours.\nScheduling: A strict schedule shall be developed and adhered to, ensuring maintenance is performed within the month scheduled to maintain Joint Commission compliance. Schedule shall be submitted to the COR 2 Weeks in advance of normal work start. \nEmergency visits shall be exempted from the schedule requirements and may require off hour availability. Responding technicians are required to report on site within a 4 hour period from service call initiation.\n\n\n        END OF SCOPE OF WORK SECTION","origin":"detail"},"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","phone":"410-637-1513","title":"Contracting Officer"}],"place_of_performance":{"zip":"21201","city":{"name":"Baltimore"},"state":{"name":"MD"},"street":"Department of Veterans Affairs VAMC","street2":"10 N Greene St"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["333912"],"award":{"awardee":{}},"attachments":[{"resource_id":"dc903520fecd45e4bdaccf7156b288b0","name":"36C24526Q0081_1.docx","kind":"file","mime_type":".docx","size_bytes":23077,"posted_at":"2025-10-21T18:58:52.112Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dc903520fecd45e4bdaccf7156b288b0/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"W31P4Q27RA010","latest_notice_id":"cdef7068a7374706adeb240e890111c7","title":"COMPRESSOR UNIT","solicitation_number":"W31P4Q27RA010","notice_type":"o","first_type":"o","first_posted":"2026-10-15","last_posted":"2026-10-15","notices":2,"due_at":"2026-11-26T22:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W31P4Q","office_name":"W6QK ACC-RSA","naics":"333912","psc":"4310","set_aside":null,"state":"TX","county":"48141","county_name":"El Paso County","city":"4826664","city_name":"Fort Bliss","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-16T03:38:05.572608Z"},{"key":"SPE7M127U1196","latest_notice_id":"4106a79c3f96431986b535579c3e8ad9","title":"43--PARTS KIT,COMPRESSOR","solicitation_number":"SPE7M127U1196","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M1","office_name":"DLA WEAPONS SUPPORT","naics":"333912","psc":"43","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 16. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"SPE7LX27U0910","latest_notice_id":"82af4636e1804798be28b68c4ac6d22c","title":"43--RING,PISTON","solicitation_number":"SPE7LX27U0910","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7LX","office_name":"DLA WEAPONS SUPPORT","naics":"333912","psc":"43","set_aside":"HZC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 13. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":26,"indexable":false}