{"canonical":"https://sealedbidder.com/opportunities/36c24526q0027","key":"36C24526Q0027","url":"https://sealedbidder.com/opportunities/36c24526q0027","title":"J045--Loch Raven VAMC Boiler Maintenance Contract Base plus Four Option Years","solicitation_number":"36C24526Q0027","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-10-09T15:00:00Z","first_posted":"2025-09-25","last_posted":"2025-09-25","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"238220","psc":"J045","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"b9d9015d635443b283a20b5332663cb9","title":"J045--Loch Raven VAMC Boiler Maintenance Contract Base plus Four Option Years","solicitation_number":"36C24526Q0027","notice_type":"r","base_type":"r","posted":"2025-09-25","posted_at":"2025-09-25T17:10:07.618Z","due_at":"2025-10-09T15:00:00Z","due_date":"2025-10-09","cancelled":false,"archived":true,"archive_date":"2025-12-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b9d9015d635443b283a20b5332663cb9/view","enriched":true,"history":[{"index":3,"title":"J045--Loch Raven VAMC Boiler Maintenance Contract Base plus Four Option Years","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-25T17:10:07.618Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b9d9015d635443b283a20b5332663cb9","solicitation_number":"36C24526Q0027"}]}],"latest_notice_id":"b9d9015d635443b283a20b5332663cb9","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-09-25","posted_at":"2025-09-25T17:10:07.618Z","created_at":"2025-09-25T17:10:05.372Z","modified_at":"2025-12-09T04:55:45.165Z","response_deadline":{"raw":"2025-10-09T11:00:00-04:00","utc":"2025-10-09T15:00:00Z","date":"2025-10-09","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b9d9015d635443b283a20b5332663cb9/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J045--Loch Raven VAMC Boiler Maintenance Contract Base plus Four Option Years","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-12-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"J045--Loch Raven VAMC Boiler Maintenance Contract Base plus Four Option Years","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-25T17:10:07.618Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b9d9015d635443b283a20b5332663cb9","solicitation_number":"36C24526Q0027"}],"contacts":[{"name":"William Chris Galletta","role":"primary","email":"William.Galletta@va.gov","phone":"410-637-1506","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"b9d9015d635443b283a20b5332663cb9","lineage_id":"b9d9015d635443b283a20b5332663cb9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-28T02:14:42.666957650Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4cc4dbaf890de349eca5cda253a3039e326447e554bede7a998c261dd115c3a5","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-28T02:14:42.666957650Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven VA Medical Center.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0027 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, \nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of \nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include \napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these \nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the \nperformance requirements while complying with applicable limitations in \nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Thursday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov \n\n\nLoch Raven Boiler Preventative Maintenance Contract \n\nLoch Raven VAMC\n\n\n\n\n\nGeneral: \nVISN 5 The VA Maryland Health Care System is dedicated to improving the lives of Veterans and their families every day. Our health care teams are deeply experienced and guided by the needs of Veterans, their families, and caregivers. The Loch Raven medical center boiler program is comprised of 12 decentralized boilers across 7 buildings. The proposed contract will improve preventative maintenance, inspections and service maintenance to this equipment. Preventative maintenance involvesÂ functional checks, servicing, repairing, or replacing of necessary parts for all boilers on campus. These cost-effective practices keep equipment operational and running smoothly, reducing down time extending operating life and decreasing impact to patients. \n\nAbout the sites:\n\nTheÂ Loch Raven VA Community Living & Rehabilitation Center Provides rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s. The surrounding campus provides services including mental health care, audiology, care for Veterans who are blind or have low vision, and more.\n\n\n                                            \nPlanned preventative maintenance, which is scheduled maintenance aimed at making repairs BEFORE failure occurs. Tasks like cleaning equipment or replacing air/water filters represent a form of routine preventative maintenance because there is a set cadence that occurs regularly regardless of how the equipment is running. Here, you're preventing it from breaking down or running inefficiently.\nPlanned unscheduled maintenance, which is having a strategy in place to repair or replace an asset as quickly as possible when it fails. Replacing and/or repairing gaskets or a compressor can be considered unscheduled because it usually occurs on an as-needed basis whenever wear is present or the unit breaks down. This situation can also incorporate a planning element by either having real OEM replacement parts on hand or budgeting for the cost of repairing/replacing a failed part.\n\n\n\n\nCONTRACTOR PERSONNEL\n\nA. Technician Qualifications. All work shall be performed by qualified boiler technicians,\nexperienced and qualified to work on the specific makes and models of equipment listed\nin this contract. The Contractor shall submit to and for the approval of the Contracting\nOfficer, certification and a list of credentials of the qualified boiler technicians.\nTechnicians shall have completed at least a one-year trade school and have a minimum of\nfive (5) years successful experience in the field. The experience shall be largely with\ninstitutional and industrial boilers. In addition, the technician shall have demonstrated\nexperience in conducting equipment inspection and performing testing in compliance\nwith the VA safety testing manual at three (3) or more VA facilities within the past three\n(3) years.\n\nTechnicians shall demonstrate familiarity with and ready access to the current versions of the following references: \n\nNFPA 85, Boiler and Combustion Systems Hazard Code, latest edition.\n\nVHA Boiler Plant Safety Device Testing Manual, current edition.\n\n\nTerms:\n\nStationary Engineer A stationary engineer, often referred to as a boiler operator or power engineer, is responsible for the operation, maintenance, and repair of stationary engines, boilers, and other mechanical equipment that provide utilities (such as heating, cooling, and power) to buildings, industrial plants, and other facilities. Technician should be qualified in several different makes and models of boiler equipment. Technician should be able to inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may need repair. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nBoiler Technician: A boiler technician will be responsible for adhering to the preventative maintenance program described in the local SOP and superseded by directive 1810. All safety device testing will be in accordance with the United States Department of Veterans Affairs VHA Boiler and Associated Plant Safety Device Testing Manual, current edition. Technicians should be qualified or its equivalent to boiler WG-5402 series as described in the OPM guidelines. Technicians should be able to diagnose, troubleshoot, repair and inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may be required. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nQualified Professional Inspector: A Qualified Professional Inspector is any one or combination of:\na. A boiler inspector who has a valid certificate from the National Board of Boiler and Pressure Vessel Inspectors.\nb. A boiler inspector who has qualified by passing a written examination under the laws, rules and regulations of the State of Maryland.\nc. A boiler inspector who is regularly employed as a boiler inspector/testing by a\njurisdiction that has adopted and administers one or more sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the AMSE Conference\nCommittee.\nd. A boiler inspector who is regularly employed by an insurance company that has been licensed or registered by the appropriate authority of a state of the United States to write boiler and pressure vessel insurance.\n\nThe contractor must provide a list of three (3) reference contacts that have been provided\nservice on similar or identical equipment. The contractor must provide authenticated\nfactory training certificates or credentials (or acceptable substitute as approved by the\nCOR) for any personnel who are working on any VA equipment. The VA specifically\nreserves the right to reject any of the contractor s personnel and refuse them permission\nto work on VA equipment.\n\n\nAreas to be maintained:\nLoch Raven Rehabilitation & Medical Center is located at 3900 Loch Raven Boulevard, Baltimore MD, 21218 all boiler rooms.  \n\n\nLoch Raven\nEquipment     Model                Model #               Fuel#                Location\nBoiler\nCleaver Brooks\n        OLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nCleaver Brooks\n        OLO94490     CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nLochinvar\n       CBN215 \nNatural Gas\nBldg #2 Rear Maintenance Room\nBoiler\n    Patterson Kelly\n       SC-1000 \nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\n           Patterson Kelly \n       SC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\n               A.O. Smith\n            19-4\nNatural Gas\nBldg #5 Boiler Room #1\nBoiler\n                  Solaris\n     SOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\n   Solaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\n              Wel Mclain \n         EG-75\nNatural Gas\nBldg #6 Radiology\nBoiler\n                  LAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\n                  LAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\n     Patterson Kelly\n        SC-1000\nDual Fuel\nBldg #7 Boiler Room\n\n\nPreventive maintenance breakdown\nThe Contractor shall provide all personnel, management, material, parts, equipment, supplies,\nand labor to perform: Annual inspection, preventive maintenance, and repairs on eleven (12) hot water boilers located at the Loch Raven VAMC. The inspection, maintenance, and repairs shall be performed by qualified boiler technicians. The contractor will perform all preventive\nmaintenance service and functional test to ensure that the equipment performs in compliance\nwith manufacturers operating and maintenance instructions. A written service report will provide a detailed description of work performed and cost, which includes an itemized\nbreakdown for labor, hours, parts, material, and warranty information.\n\nInspection and testing frequency chart:\n\n#\nItem\n        Frequency\n       Note\n1\nInspect furnace and other internal surfaces, closures and accessories\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n2\nInspect exterior of unit, casing, supports, closures, accessories, valves, controls\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n3\nCheck all boilers for fouling and\ncombustion gas flow\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n4\nTube leak check\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n5\nAdjust burner combustion settings and\ncalibrate oxygen trim\n        6 Month\n\n6\nCheck vibration of burner fans\n        6 Month\n\n7\nCalibrate instrumentation, monitoring, and control systems\n        6 Month\n\n8\nCalibrate pressure gauges and\nthermometers\n        6 Month\n\n9\nOperational test of Safety Devices\n        6 Month\n\na.\nLow-water cutoff (slow drain)\n        Monthly\n\nb.\nFire each boiler and the pilot on the alternate fuel for 1 hour\n        Monthly\n\nc.\nLow water cut off\n        Monthly\n\nd.\nAuxiliary low water cut off (slow drain)\n        Monthly\n\ne.\nHigh water alarm\n        Monthly\n\nf.\nLow water alarm\n         Monthly\n\ng.\nWater safety valves\n        Yearly\n\nh.\nWater safety valve operational test\n        6 Month\n\ni.\nFlame scanner\n          Monthly\n\nj.\nCheck gas vent valve for leaks\n        6 Month\n\nk.\nHigh gas fuel pressure cut off\n        6 Month\n\nl.\nLow gas fuel pressure cut off\n        6 Month\n\nm.\nGas fuel safety shut off valves proof of closure\n        6 Month\n\nn.\nLeak test gas fuel safety shut off valves\n        6 Month\n\no.\nLow atomizing pressure for fuel oil\n        6 Month\n*Building 1 boilers only\np.\nHigh fuel oil pressure cut off\n        6 Month\n*Building 1 boilers only\nq.\nFuel oil safety shut off valves proof of closure\n        6 Month\n*Building 1 boilers only\nr.\nLeak test fuel oil safety shut off valves\n        6 Month\n*Building 1 boilers only\ns.\nCheck operation of liquid petroleum gas pilot\n        6 Month\n*Building 1 boilers only\nt.\nLow pilot gas pressure cut out\n        6 Month\n\nu.\nForced draft fan motor interlock\n        6 Month\n\nv.\nForced draft fan damper wide open for purge\n        6 Month\n\nw.\nBoiler outlet damper wide open for purge\n        6 Month\n\nx.\nPurge air flow interlock\n        6 Month\n\ny.\nTiming for pre-purge\n        6 Month\n\nz.\nTiming for post   purge\n        6 Month\n\naa.\nIgniter timing\n        6 Month\n\nbb.\nLow fire position interlock\n        6 Month\n\ncc.\nCombustion air interlock\n        6 Month\n\ndd.\nMain flame out; i.e. time to close valves\n        6 Month\n\nee.\nIgnition flame out; i.e. time to close valves\n        6 Month\n\nff.\nMinimum igniter flame test\n        6 Month\n\ngg.\nScanner not sensing ignition spark\n        6 Month\n\nhh.\nLow oxygen alarm and/or cut out\n        6 Month\n\nii.\nPre-purge setting of flue gas recirculation damper\n        6 Month\n\njj.\nInterlock of building outside air damper\n        6 Month\n\nkk.\nBurner/heating element control\n        6 Month\n\nll.\nCO and combustion gas detection equipment testing\n        6 Month\n\nmm.\nBoiler emergency button testing\n        6 Month\n\n\nContractor shall document all Preventative Maintenance in the binder provided by COR. Documentation will be in accordance with Loch Raven Boiler SOP & VHA Boiler Plant Safety Device Testing Manual, current edition. Quality control and Contractor leadership shall ensure the documentation is correct and accurate before turning in to COR.\n\nAnnual Maintenance/Operational Maintenance\nA. Monthly\na. Test and adjust water treatment\nb. Operate all alarm devices\nB. Semi-Annual\na. Check furnace pressure\nb. Check combustion gas leaks into boiler room\nC. Annual\na. Open Boilers\nb. Clean waterside of boilers\nc. Clean fireside and repair refractory\n\nRepairs\nA. All repairs to boilers and pressure vessels shall comply with the American Society of\nMechanical Engineers (ASME) Boiler and Pressure Vessel Code. No welded repairs are\npermitted except by certified welders using Code-approved procedures. Repair and\nrecord of certification, and the qualification of welders must be provided to the COR\nupon completion of all repairs. Bids will be adjusted at a flat rate to include $100,000 at the base of the contract to account for emergency repairs annually. This emergency repair cost will be added to the estimated annual preventative maintenance cost. Additional funding may be required for additional repairs.\n\nB. Hydrostatic testing of boilers and pressure vessels must be conducted after a repair            \nor a tube replacement, or when the boiler or pressure vessel integrity is in doubt. \nHydrostatic pressure must be limited to 150 percent of normal operating pressure of \nthe boiler or pressure vessel.\n\nInspection, Testing and Calibration Requirements:\nA. Technicians shall provide all tools and labor necessary to perform inspection,\ntuning, testing, calibrating, and adjustments of burners and boiler controls as\nspecified below. This shall be done in accordance with the schedule listed below.\n\nB. Instrumentation, monitoring and data management systems as listed below shall be  calibrated every six months. Calibration shall follow VHA Boiler Plant Safety Device Testing Manual, current edition\n\nC. Provide at least two weeks  notice to the Contracting Officer s Representative\n(COR) prior to performing the work. Work cannot be scheduled during heavy\nheat load periods. Only one boiler at a time can be out of service for the\ninspection, testing and calibration procedures. Work must be conducted when\nthe COR is onsite to monitor the work.\n\nD. VAMC will have the boilers that are to be serviced prepared for technicians upon\ntheir scheduled arrival. This include having the boilers fully warmed and at\nnormal operating temperature/pressure.\n\nE. The inspection, testing and calibration shall comply with:\na. The recommendations and requirements of VHA Boiler Plant Safety\nDevices Testing Manual, current edition.\nb. The written recommendations of the equipment manufacturers.\nc. The requirements and recommendations of NFPA 85, Boiler and\nCombustion Systems Hazards Code, including applicable appendices.\nd. Burner performance requirements in this document.\n\nF. A summary of the work is as follows, the below summary is not inclusive, refer to the inspection/testing frequency:\na. Review boiler log sheets and alarm and trouble reports.\nb. Review records that show combustion (flue gas oxygen and carbon\nmonoxide).\nc. Perform overall visual inspection of systems. Verify that systems comply\nwith referenced codes and VAMC requirements stated in this contract.\nd. Test and record the operation and set points of all burner/boiler safety\ninterlock devices. Refer to list below. Verify that the set points and\noperating points are within approximately 20% of normal operating\nparameters. Make adjustments as necessary and record the new settings.\nThe operation of a device must result in burner shutdown and/or proper\nalarm operation.\ne. Operate burner(s) on each fuel from low fire to high fire and back to low fire in at least six increments and record combustion performance (flue gas oxygen, carbon monoxide, NOx where applicable), fuel train pressures, atomizing train pressures, burner pressures, stack temperatures, boiler load output.\nf. Compare the combustion performance data with VAMC requirements (see\nbelow) and previous readings. If necessary, make adjustments to the fuel\nflow and combustion air controllers, control valves and dampers to obtain\nthe required performance. Record the new performance data.\ng. Verify accuracy of instrumentation listed below. Verify that all devices are\nproperly selected for the application in terms of type, size, set point range,\nperformance, code approval. Calibrate all instruments that are not within\nmanufacturer s specifications for accuracy.\nh. Immediately inform COR of any recommended repairs of modifications.\n\nG. All of interlocks and safety devices to be inspected and tested on each\nboiler/burner/equipment, are contained in the VHA Boiler Plant Safety Device\nTesting Manual, current edition, along with testing procedures.\n\nH.  Required burner performance:\na. Turndown (ratio of maximum and minimum firing rates): 10/1 8/1 5/1 4/1\n(Refer to original burner specification).\nb. Achieve, but do not exceed, boiler maximum heat output rating. Measure\nfuel input at minimum and maximum firing rates.\nc. Maximum carbon monoxide: 200 parts per million (ppm)\nd. Maximum NOx: (refer to original burner specification)\ne. Flue gas oxygen: 2.4   4.2%\nf. Flue gas oxygen (low excess air burners): 1.0   2.0%\ng. No visible smoke, except on heavy oil fuel maximum opacity is 20%.\nComply with local emissions regulations.\nh.  Flames shall be stable with no pulsations, shall be retained near burner,\nno blow off or flashback, no constant flame impingement on refractory or\nwater walls.\n\nI. List of instrumentation and controls to be inspected and calibrated:\na. Boiler outlet draft controllers\nb. Boiler water level controllers\nc. All pressure and temperature sensors and transmitters\nd. All signal processing and readout devices\n\nJ. Report requirements:\na. Provide complete written report of the inspection fully describing all tests\nperformed, all findings, and recommendations. The report shall have two\nsections the first section will be in a table form with four columns:\ni. The first column labeled  FUNCTION  with pass or fail\nii. The second column labeled  Devices  list the device number and\ndescription in accordance with the VHA Boiler Plant Safety Devices\nTesting Manual, current edition.\niii. The third column labeled  Deficiencies-Recommendations \niv. The fourth column labeled  Corrective Actions  list any corrective\nactions taken during the inspection.\nb. Furnish the report within one week of each inspection in  Microsoft Word \nformat by email to the COR. Provide hard copies of data sheets and flue\ngas analyzer  strip  printouts to the COR within one week of visit.\nc. All safety-related deficiencies shall be immediately reported to the COR\nand/or Chief Engineer during the inspection visit.\n\n\n\nDocumentation and Policy Review\nContractors will be required to have a kickoff meeting to review 1810 hot water boiler directive & VHA Boiler Plant Safety Devices Testing Manual, current edition. This will be reviewed annually with the COR for any changes.\n\nThe Contractor shall establish and maintain a Quality Control Program that ensures that all\nrequirements of the contract are provided as specified. This individual shal meet with the COR and CO quarterly to update or provide deliverables.\n\nContractor shall provide annual training on all the Boiler Equipment for designated employees\nassigned to the Loch Raven campus (approximately 20 personnel) over two-day, eight (8) hour\ncourses. The training shall be in accordance with the manufacturer s  Commissioning and Start\nUp  operation manuals. In addition, the training shall cover the following topics:\n\nA. Proper operation of all boilers listed in the scope of work\nB. Hydronic system overview\nC. Maintenance log procedures and regulations\nD. How to recognize failures of expansion tanks, and unsafe conditions\nE. PRV discharge conditions and inspections\nF. Inspection of CO monitors\n\nDocumentation and deliverables shall be provided to COR. Signed and dated documents will be filed annually for training. Contractor to provide date of draining 30 days in advance to the federal government.\n\nHours of operation & Reporting for Duty: Contractor staff shall report for duty to the designated locations for each campus to be established by the Contracting Officer Representative (COR). The contractors shall review the required tasks and scheduling with the Facilities and Engineering supervisor Point Of Contact (POC) prior to the start of each workday. The workday hours shall be coordinated with the COR but will generally be an 8-hour day beginning at 8:00am. Hours may be adjusted/flexed to fit each campus  need. This will be determined by the COR and be presented in written format for any schedule changes. Schedules shall be made to meet boiler preventative maintenance requirements.\n\nReporting Requirements: Upon completion of work, the Contractor shall document services electronically or written in a legible format and provide to the COR. If services are performed after normal businesses hours, the Contractor shall report to the VA site manager or designee. Contractor to provide the service report to the COR on the next business day (with the signature of the VA site manager) to substantiate hours work performed.\n\nInvoicing: Contractor to submit invoicing within monthly intervals. Invoicing is to be line itemed and as detailed as possible. Labor hours are to be clearly marked by trade. Items that are not included in afore mentioned services agreement are not to be invoiced through this contract. Invoicing will be reviewed by the Contracting Officer Representative (COR) for authenticity. Items not to be billed to this contract will be equipment damage, storage fees, fuel fees, rental costs, unverified hours, travel cost, additional fees, taxes, etc. Invoices will be rejected and be required to be resubmitted if errors are detected. \n\nOrdering Activities and Officers: The Contractor and/or its staff shall not accept any instructions issued by any other person(s) other than the Contracting Officer, the COR, or his/her delegated representative acting within the limits of his/her authority. Purchase of materials, orders or additional service will be documented and coordinated through the COR.\n\nSafety and Security Precautions:\n\nThe Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety.  The requirements include but are not limited to those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926.  Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthy working conditions for its employees.\n\nContractor shall provide his/her employees with the necessary safety equipment required for performance of the contract. The contractor shall take precautions regarding fire and safety policies/procedures within VAMC and their associated Clinics. \n\nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\n\nNo flammable liquids shall be stored in non-designated areas or used in the medical center without communication and written approval from the Contracting Officer Representative (COR). \n\nThe Contractor and/or its staff shall immediately notify the COR of any existing or potentially unsafe conditions, i.e., frayed electrical cord, dripping, or seeping of fluids. \n\nThe Contractor shall receive from the COR a permit for all cutting, welding, soldering, or  Hot Work  of any kind. All permits shall be prominently displayed during all activities. \n\nAll necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads.\n\nHAZARDOUS MATERIAL REPORTING: \nThe Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center.  Hazardous materials must be inventoried when received and at the project s completion.  The amounts used shall be maintained for the project duration. \n  \nHazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative.\n\nIn the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer.  The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761. \n\nSmoking Policy: Smoking is not permitted within the VAMC facilities. Smoking is prohibited in building or on the campus grounds. Contractors found smoking in/on campus, their vehicles will be removed from campus and contractors supervision notified.\nService Calls: Contractor s to provide emergency contacts, standard point of contacts name, phone number and email address for contractor POC. This contract is expected to have 24 hour response to boiler failures with a 2 hour window for emergency response to repair.\nChanges. Only those services specified herein are authorized. Services that are not included in the contract shall NOT be provided unless authorized via a modification issued by the Contracting Officer.  \nOvertime: Overtime or evening rates shall be approved by the COR or his/her designated representative prior to services being rendered.\nBadges and Parking: Contractor personnel are required to wear identification (I. D.) badges issued by the VA Security Office during the entire time they are on the grounds of the VAMC or one of its clinics. \nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the VAMC Security Office. The Government shall not validate or reimburse for parking violations under any circumstance. \nAt the Loch Raven Campus, Contractors will park along the designated contractors parking area The Alameda. Contractors may temporarily park vehicles closer to buildings for  drop off  purposes that do not exceed 30 minutes per day unless otherwise discussed with the COR. Contractors may not offload and leave vehicles in the loading dock location, blocking rear building entrances or in fire lanes.\n\nNational Holidays:  Listed below are the eleven national holidays:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day \nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day \nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day \nSecond Monday in October\nVeterans Day \nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nAlso included would be any day specifically declared by the President of the United States of America as a National holiday.\n\n\nPoint of Contact and COR:\nAll questions, clarifications, or ambiguities must be in writing to:\n Louis Hopson  Louis.Hopson@va.gov \n 3900 Loch Raven Blvd    443-986-2593\n Baltimore, MD  21218\n (410) 605-7000 x55889","text":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven VA Medical Center.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0027 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of\nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these\nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the\nperformance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Thursday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov\n\nLoch Raven Boiler Preventative Maintenance Contract\n\nLoch Raven VAMC\n\nGeneral:\nVISN 5 The VA Maryland Health Care System is dedicated to improving the lives of Veterans and their families every day. Our health care teams are deeply experienced and guided by the needs of Veterans, their families, and caregivers. The Loch Raven medical center boiler program is comprised of 12 decentralized boilers across 7 buildings. The proposed contract will improve preventative maintenance, inspections and service maintenance to this equipment. Preventative maintenance involvesÂ functional checks, servicing, repairing, or replacing of necessary parts for all boilers on campus. These cost-effective practices keep equipment operational and running smoothly, reducing down time extending operating life and decreasing impact to patients.\n\nAbout the sites:\n\nTheÂ Loch Raven VA Community Living & Rehabilitation Center Provides rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s. The surrounding campus provides services including mental health care, audiology, care for Veterans who are blind or have low vision, and more.\n\nPlanned preventative maintenance, which is scheduled maintenance aimed at making repairs BEFORE failure occurs. Tasks like cleaning equipment or replacing air/water filters represent a form of routine preventative maintenance because there is a set cadence that occurs regularly regardless of how the equipment is running. Here, you're preventing it from breaking down or running inefficiently.\nPlanned unscheduled maintenance, which is having a strategy in place to repair or replace an asset as quickly as possible when it fails. Replacing and/or repairing gaskets or a compressor can be considered unscheduled because it usually occurs on an as-needed basis whenever wear is present or the unit breaks down. This situation can also incorporate a planning element by either having real OEM replacement parts on hand or budgeting for the cost of repairing/replacing a failed part.\n\nCONTRACTOR PERSONNEL\n\nA. Technician Qualifications. All work shall be performed by qualified boiler technicians,\nexperienced and qualified to work on the specific makes and models of equipment listed\nin this contract. The Contractor shall submit to and for the approval of the Contracting\nOfficer, certification and a list of credentials of the qualified boiler technicians.\nTechnicians shall have completed at least a one-year trade school and have a minimum of\nfive (5) years successful experience in the field. The experience shall be largely with\ninstitutional and industrial boilers. In addition, the technician shall have demonstrated\nexperience in conducting equipment inspection and performing testing in compliance\nwith the VA safety testing manual at three (3) or more VA facilities within the past three\n(3) years.\n\nTechnicians shall demonstrate familiarity with and ready access to the current versions of the following references:\n\nNFPA 85, Boiler and Combustion Systems Hazard Code, latest edition.\n\nVHA Boiler Plant Safety Device Testing Manual, current edition.\n\nTerms:\n\nStationary Engineer A stationary engineer, often referred to as a boiler operator or power engineer, is responsible for the operation, maintenance, and repair of stationary engines, boilers, and other mechanical equipment that provide utilities (such as heating, cooling, and power) to buildings, industrial plants, and other facilities. Technician should be qualified in several different makes and models of boiler equipment. Technician should be able to inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may need repair. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nBoiler Technician: A boiler technician will be responsible for adhering to the preventative maintenance program described in the local SOP and superseded by directive 1810. All safety device testing will be in accordance with the United States Department of Veterans Affairs VHA Boiler and Associated Plant Safety Device Testing Manual, current edition. Technicians should be qualified or its equivalent to boiler WG-5402 series as described in the OPM guidelines. Technicians should be able to diagnose, troubleshoot, repair and inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may be required. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nQualified Professional Inspector: A Qualified Professional Inspector is any one or combination of:\na. A boiler inspector who has a valid certificate from the National Board of Boiler and Pressure Vessel Inspectors.\nb. A boiler inspector who has qualified by passing a written examination under the laws, rules and regulations of the State of Maryland.\nc. A boiler inspector who is regularly employed as a boiler inspector/testing by a\njurisdiction that has adopted and administers one or more sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the AMSE Conference\nCommittee.\nd. A boiler inspector who is regularly employed by an insurance company that has been licensed or registered by the appropriate authority of a state of the United States to write boiler and pressure vessel insurance.\n\nThe contractor must provide a list of three (3) reference contacts that have been provided\nservice on similar or identical equipment. The contractor must provide authenticated\nfactory training certificates or credentials (or acceptable substitute as approved by the\nCOR) for any personnel who are working on any VA equipment. The VA specifically\nreserves the right to reject any of the contractor s personnel and refuse them permission\nto work on VA equipment.\n\nAreas to be maintained:\nLoch Raven Rehabilitation & Medical Center is located at 3900 Loch Raven Boulevard, Baltimore MD, 21218 all boiler rooms.\n\nLoch Raven\nEquipment Model Model # Fuel# Location\nBoiler\nCleaver Brooks\nOLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nCleaver Brooks\nOLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nLochinvar\nCBN215\nNatural Gas\nBldg #2 Rear Maintenance Room\nBoiler\nPatterson Kelly\nSC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\nPatterson Kelly\nSC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\nA.O. Smith\n19-4\nNatural Gas\nBldg #5 Boiler Room #1\nBoiler\nSolaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\nSolaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\nWel Mclain\nEG-75\nNatural Gas\nBldg #6 Radiology\nBoiler\nLAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\nLAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\nPatterson Kelly\nSC-1000\nDual Fuel\nBldg #7 Boiler Room\n\nPreventive maintenance breakdown\nThe Contractor shall provide all personnel, management, material, parts, equipment, supplies,\nand labor to perform: Annual inspection, preventive maintenance, and repairs on eleven (12) hot water boilers located at the Loch Raven VAMC. The inspection, maintenance, and repairs shall be performed by qualified boiler technicians. The contractor will perform all preventive\nmaintenance service and functional test to ensure that the equipment performs in compliance\nwith manufacturers operating and maintenance instructions. A written service report will provide a detailed description of work performed and cost, which includes an itemized\nbreakdown for labor, hours, parts, material, and warranty information.\n\nInspection and testing frequency chart:\n\n#\nItem\nFrequency\nNote\n1\nInspect furnace and other internal surfaces, closures and accessories\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n2\nInspect exterior of unit, casing, supports, closures, accessories, valves, controls\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n3\nCheck all boilers for fouling and\ncombustion gas flow\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n4\nTube leak check\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n5\nAdjust burner combustion settings and\ncalibrate oxygen trim\n6 Month\n\n6\nCheck vibration of burner fans\n6 Month\n\n7\nCalibrate instrumentation, monitoring, and control systems\n6 Month\n\n8\nCalibrate pressure gauges and\nthermometers\n6 Month\n\n9\nOperational test of Safety Devices\n6 Month\n\na.\nLow-water cutoff (slow drain)\nMonthly\n\nb.\nFire each boiler and the pilot on the alternate fuel for 1 hour\nMonthly\n\nc.\nLow water cut off\nMonthly\n\nd.\nAuxiliary low water cut off (slow drain)\nMonthly\n\ne.\nHigh water alarm\nMonthly\n\nf.\nLow water alarm\nMonthly\n\ng.\nWater safety valves\nYearly\n\nh.\nWater safety valve operational test\n6 Month\n\ni.\nFlame scanner\nMonthly\n\nj.\nCheck gas vent valve for leaks\n6 Month\n\nk.\nHigh gas fuel pressure cut off\n6 Month\n\nl.\nLow gas fuel pressure cut off\n6 Month\n\nm.\nGas fuel safety shut off valves proof of closure\n6 Month\n\nn.\nLeak test gas fuel safety shut off valves\n6 Month\n\no.\nLow atomizing pressure for fuel oil\n6 Month\n*Building 1 boilers only\np.\nHigh fuel oil pressure cut off\n6 Month\n*Building 1 boilers only\nq.\nFuel oil safety shut off valves proof of closure\n6 Month\n*Building 1 boilers only\nr.\nLeak test fuel oil safety shut off valves\n6 Month\n*Building 1 boilers only\ns.\nCheck operation of liquid petroleum gas pilot\n6 Month\n*Building 1 boilers only\nt.\nLow pilot gas pressure cut out\n6 Month\n\nu.\nForced draft fan motor interlock\n6 Month\n\nv.\nForced draft fan damper wide open for purge\n6 Month\n\nw.\nBoiler outlet damper wide open for purge\n6 Month\n\nx.\nPurge air flow interlock\n6 Month\n\ny.\nTiming for pre-purge\n6 Month\n\nz.\nTiming for post purge\n6 Month\n\naa.\nIgniter timing\n6 Month\n\nbb.\nLow fire position interlock\n6 Month\n\ncc.\nCombustion air interlock\n6 Month\n\ndd.\nMain flame out; i.e. time to close valves\n6 Month\n\nee.\nIgnition flame out; i.e. time to close valves\n6 Month\n\nff.\nMinimum igniter flame test\n6 Month\n\ngg.\nScanner not sensing ignition spark\n6 Month\n\nhh.\nLow oxygen alarm and/or cut out\n6 Month\n\nii.\nPre-purge setting of flue gas recirculation damper\n6 Month\n\njj.\nInterlock of building outside air damper\n6 Month\n\nkk.\nBurner/heating element control\n6 Month\n\nll.\nCO and combustion gas detection equipment testing\n6 Month\n\nmm.\nBoiler emergency button testing\n6 Month\n\nContractor shall document all Preventative Maintenance in the binder provided by COR. Documentation will be in accordance with Loch Raven Boiler SOP & VHA Boiler Plant Safety Device Testing Manual, current edition. Quality control and Contractor leadership shall ensure the documentation is correct and accurate before turning in to COR.\n\nAnnual Maintenance/Operational Maintenance\nA. Monthly\na. Test and adjust water treatment\nb. Operate all alarm devices\nB. Semi-Annual\na. Check furnace pressure\nb. Check combustion gas leaks into boiler room\nC. Annual\na. Open Boilers\nb. Clean waterside of boilers\nc. Clean fireside and repair refractory\n\nRepairs\nA. All repairs to boilers and pressure vessels shall comply with the American Society of\nMechanical Engineers (ASME) Boiler and Pressure Vessel Code. No welded repairs are\npermitted except by certified welders using Code-approved procedures. Repair and\nrecord of certification, and the qualification of welders must be provided to the COR\nupon completion of all repairs. Bids will be adjusted at a flat rate to include $100,000 at the base of the contract to account for emergency repairs annually. This emergency repair cost will be added to the estimated annual preventative maintenance cost. Additional funding may be required for additional repairs.\n\nB. Hydrostatic testing of boilers and pressure vessels must be conducted after a repair\nor a tube replacement, or when the boiler or pressure vessel integrity is in doubt.\nHydrostatic pressure must be limited to 150 percent of normal operating pressure of\nthe boiler or pressure vessel.\n\nInspection, Testing and Calibration Requirements:\nA. Technicians shall provide all tools and labor necessary to perform inspection,\ntuning, testing, calibrating, and adjustments of burners and boiler controls as\nspecified below. This shall be done in accordance with the schedule listed below.\n\nB. Instrumentation, monitoring and data management systems as listed below shall be calibrated every six months. Calibration shall follow VHA Boiler Plant Safety Device Testing Manual, current edition\n\nC. Provide at least two weeks notice to the Contracting Officer s Representative\n(COR) prior to performing the work. Work cannot be scheduled during heavy\nheat load periods. Only one boiler at a time can be out of service for the\ninspection, testing and calibration procedures. Work must be conducted when\nthe COR is onsite to monitor the work.\n\nD. VAMC will have the boilers that are to be serviced prepared for technicians upon\ntheir scheduled arrival. This include having the boilers fully warmed and at\nnormal operating temperature/pressure.\n\nE. The inspection, testing and calibration shall comply with:\na. The recommendations and requirements of VHA Boiler Plant Safety\nDevices Testing Manual, current edition.\nb. The written recommendations of the equipment manufacturers.\nc. The requirements and recommendations of NFPA 85, Boiler and\nCombustion Systems Hazards Code, including applicable appendices.\nd. Burner performance requirements in this document.\n\nF. A summary of the work is as follows, the below summary is not inclusive, refer to the inspection/testing frequency:\na. Review boiler log sheets and alarm and trouble reports.\nb. Review records that show combustion (flue gas oxygen and carbon\nmonoxide).\nc. Perform overall visual inspection of systems. Verify that systems comply\nwith referenced codes and VAMC requirements stated in this contract.\nd. Test and record the operation and set points of all burner/boiler safety\ninterlock devices. Refer to list below. Verify that the set points and\noperating points are within approximately 20% of normal operating\nparameters. Make adjustments as necessary and record the new settings.\nThe operation of a device must result in burner shutdown and/or proper\nalarm operation.\ne. Operate burner(s) on each fuel from low fire to high fire and back to low fire in at least six increments and record combustion performance (flue gas oxygen, carbon monoxide, NOx where applicable), fuel train pressures, atomizing train pressures, burner pressures, stack temperatures, boiler load output.\nf. Compare the combustion performance data with VAMC requirements (see\nbelow) and previous readings. If necessary, make adjustments to the fuel\nflow and combustion air controllers, control valves and dampers to obtain\nthe required performance. Record the new performance data.\ng. Verify accuracy of instrumentation listed below. Verify that all devices are\nproperly selected for the application in terms of type, size, set point range,\nperformance, code approval. Calibrate all instruments that are not within\nmanufacturer s specifications for accuracy.\nh. Immediately inform COR of any recommended repairs of modifications.\n\nG. All of interlocks and safety devices to be inspected and tested on each\nboiler/burner/equipment, are contained in the VHA Boiler Plant Safety Device\nTesting Manual, current edition, along with testing procedures.\n\nH. Required burner performance:\na. Turndown (ratio of maximum and minimum firing rates): 10/1 8/1 5/1 4/1\n(Refer to original burner specification).\nb. Achieve, but do not exceed, boiler maximum heat output rating. Measure\nfuel input at minimum and maximum firing rates.\nc. Maximum carbon monoxide: 200 parts per million (ppm)\nd. Maximum NOx: (refer to original burner specification)\ne. Flue gas oxygen: 2.4 4.2%\nf. Flue gas oxygen (low excess air burners): 1.0 2.0%\ng. No visible smoke, except on heavy oil fuel maximum opacity is 20%.\nComply with local emissions regulations.\nh. Flames shall be stable with no pulsations, shall be retained near burner,\nno blow off or flashback, no constant flame impingement on refractory or\nwater walls.\n\nI. List of instrumentation and controls to be inspected and calibrated:\na. Boiler outlet draft controllers\nb. Boiler water level controllers\nc. All pressure and temperature sensors and transmitters\nd. All signal processing and readout devices\n\nJ. Report requirements:\na. Provide complete written report of the inspection fully describing all tests\nperformed, all findings, and recommendations. The report shall have two\nsections the first section will be in a table form with four columns:\ni. The first column labeled FUNCTION with pass or fail\nii. The second column labeled Devices list the device number and\ndescription in accordance with the VHA Boiler Plant Safety Devices\nTesting Manual, current edition.\niii. The third column labeled Deficiencies-Recommendations\niv. The fourth column labeled Corrective Actions list any corrective\nactions taken during the inspection.\nb. Furnish the report within one week of each inspection in Microsoft Word\nformat by email to the COR. Provide hard copies of data sheets and flue\ngas analyzer strip printouts to the COR within one week of visit.\nc. All safety-related deficiencies shall be immediately reported to the COR\nand/or Chief Engineer during the inspection visit.\n\nDocumentation and Policy Review\nContractors will be required to have a kickoff meeting to review 1810 hot water boiler directive & VHA Boiler Plant Safety Devices Testing Manual, current edition. This will be reviewed annually with the COR for any changes.\n\nThe Contractor shall establish and maintain a Quality Control Program that ensures that all\nrequirements of the contract are provided as specified. This individual shal meet with the COR and CO quarterly to update or provide deliverables.\n\nContractor shall provide annual training on all the Boiler Equipment for designated employees\nassigned to the Loch Raven campus (approximately 20 personnel) over two-day, eight (8) hour\ncourses. The training shall be in accordance with the manufacturer s Commissioning and Start\nUp operation manuals. In addition, the training shall cover the following topics:\n\nA. Proper operation of all boilers listed in the scope of work\nB. Hydronic system overview\nC. Maintenance log procedures and regulations\nD. How to recognize failures of expansion tanks, and unsafe conditions\nE. PRV discharge conditions and inspections\nF. Inspection of CO monitors\n\nDocumentation and deliverables shall be provided to COR. Signed and dated documents will be filed annually for training. Contractor to provide date of draining 30 days in advance to the federal government.\n\nHours of operation & Reporting for Duty: Contractor staff shall report for duty to the designated locations for each campus to be established by the Contracting Officer Representative (COR). The contractors shall review the required tasks and scheduling with the Facilities and Engineering supervisor Point Of Contact (POC) prior to the start of each workday. The workday hours shall be coordinated with the COR but will generally be an 8-hour day beginning at 8:00am. Hours may be adjusted/flexed to fit each campus need. This will be determined by the COR and be presented in written format for any schedule changes. Schedules shall be made to meet boiler preventative maintenance requirements.\n\nReporting Requirements: Upon completion of work, the Contractor shall document services electronically or written in a legible format and provide to the COR. If services are performed after normal businesses hours, the Contractor shall report to the VA site manager or designee. Contractor to provide the service report to the COR on the next business day (with the signature of the VA site manager) to substantiate hours work performed.\n\nInvoicing: Contractor to submit invoicing within monthly intervals. Invoicing is to be line itemed and as detailed as possible. Labor hours are to be clearly marked by trade. Items that are not included in afore mentioned services agreement are not to be invoiced through this contract. Invoicing will be reviewed by the Contracting Officer Representative (COR) for authenticity. Items not to be billed to this contract will be equipment damage, storage fees, fuel fees, rental costs, unverified hours, travel cost, additional fees, taxes, etc. Invoices will be rejected and be required to be resubmitted if errors are detected.\n\nOrdering Activities and Officers: The Contractor and/or its staff shall not accept any instructions issued by any other person(s) other than the Contracting Officer, the COR, or his/her delegated representative acting within the limits of his/her authority. Purchase of materials, orders or additional service will be documented and coordinated through the COR.\n\nSafety and Security Precautions:\n\nThe Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety. The requirements include but are not limited to those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926. Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthy working conditions for its employees.\n\nContractor shall provide his/her employees with the necessary safety equipment required for performance of the contract. The contractor shall take precautions regarding fire and safety policies/procedures within VAMC and their associated Clinics.\n\nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\n\nNo flammable liquids shall be stored in non-designated areas or used in the medical center without communication and written approval from the Contracting Officer Representative (COR).\n\nThe Contractor and/or its staff shall immediately notify the COR of any existing or potentially unsafe conditions, i.e., frayed electrical cord, dripping, or seeping of fluids.\n\nThe Contractor shall receive from the COR a permit for all cutting, welding, soldering, or Hot Work of any kind. All permits shall be prominently displayed during all activities.\n\nAll necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads.\n\nHAZARDOUS MATERIAL REPORTING:\nThe Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center. Hazardous materials must be inventoried when received and at the project s completion. The amounts used shall be maintained for the project duration.\n\nHazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative.\n\nIn the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer. The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761.\n\nSmoking Policy: Smoking is not permitted within the VAMC facilities. Smoking is prohibited in building or on the campus grounds. Contractors found smoking in/on campus, their vehicles will be removed from campus and contractors supervision notified.\nService Calls: Contractor s to provide emergency contacts, standard point of contacts name, phone number and email address for contractor POC. This contract is expected to have 24 hour response to boiler failures with a 2 hour window for emergency response to repair.\nChanges. Only those services specified herein are authorized. Services that are not included in the contract shall NOT be provided unless authorized via a modification issued by the Contracting Officer.\nOvertime: Overtime or evening rates shall be approved by the COR or his/her designated representative prior to services being rendered.\nBadges and Parking: Contractor personnel are required to wear identification (I. D.) badges issued by the VA Security Office during the entire time they are on the grounds of the VAMC or one of its clinics.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the VAMC Security Office. The Government shall not validate or reimburse for parking violations under any circumstance.\nAt the Loch Raven Campus, Contractors will park along the designated contractors parking area The Alameda. Contractors may temporarily park vehicles closer to buildings for drop off purposes that do not exceed 30 minutes per day unless otherwise discussed with the COR. Contractors may not offload and leave vehicles in the loading dock location, blocking rear building entrances or in fire lanes.\n\nNational Holidays: Listed below are the eleven national holidays:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nAlso included would be any day specifically declared by the President of the United States of America as a National holiday.\n\nPoint of Contact and COR:\nAll questions, clarifications, or ambiguities must be in writing to:\nLouis Hopson Louis.Hopson@va.gov\n3900 Loch Raven Blvd 443-986-2593\nBaltimore, MD 21218\n(410) 605-7000 x55889","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0027","place_of_performance":{"zip":"21218","city":{"name":"Baltimore"},"state":{"name":"MD"},"street":"Department of Veterans Affairs Loch Raven VAMC","street2":"3901 Loch Raven Blvd."},"product_service_code":"J045"}],"due_at":"2025-10-09T15:00:00Z","due_date":"2025-10-09","closes_at":"2025-10-09T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-28T02:50:49.787508Z","principal_notice_id":"b9d9015d635443b283a20b5332663cb9","description":{"text":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven VA Medical Center.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0027 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned,\nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of\nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include\napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these\nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the\nperformance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Thursday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov\n\nLoch Raven Boiler Preventative Maintenance Contract\n\nLoch Raven VAMC\n\nGeneral:\nVISN 5 The VA Maryland Health Care System is dedicated to improving the lives of Veterans and their families every day. Our health care teams are deeply experienced and guided by the needs of Veterans, their families, and caregivers. The Loch Raven medical center boiler program is comprised of 12 decentralized boilers across 7 buildings. The proposed contract will improve preventative maintenance, inspections and service maintenance to this equipment. Preventative maintenance involvesÂ functional checks, servicing, repairing, or replacing of necessary parts for all boilers on campus. These cost-effective practices keep equipment operational and running smoothly, reducing down time extending operating life and decreasing impact to patients.\n\nAbout the sites:\n\nTheÂ Loch Raven VA Community Living & Rehabilitation Center Provides rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s. The surrounding campus provides services including mental health care, audiology, care for Veterans who are blind or have low vision, and more.\n\nPlanned preventative maintenance, which is scheduled maintenance aimed at making repairs BEFORE failure occurs. Tasks like cleaning equipment or replacing air/water filters represent a form of routine preventative maintenance because there is a set cadence that occurs regularly regardless of how the equipment is running. Here, you're preventing it from breaking down or running inefficiently.\nPlanned unscheduled maintenance, which is having a strategy in place to repair or replace an asset as quickly as possible when it fails. Replacing and/or repairing gaskets or a compressor can be considered unscheduled because it usually occurs on an as-needed basis whenever wear is present or the unit breaks down. This situation can also incorporate a planning element by either having real OEM replacement parts on hand or budgeting for the cost of repairing/replacing a failed part.\n\nCONTRACTOR PERSONNEL\n\nA. Technician Qualifications. All work shall be performed by qualified boiler technicians,\nexperienced and qualified to work on the specific makes and models of equipment listed\nin this contract. The Contractor shall submit to and for the approval of the Contracting\nOfficer, certification and a list of credentials of the qualified boiler technicians.\nTechnicians shall have completed at least a one-year trade school and have a minimum of\nfive (5) years successful experience in the field. The experience shall be largely with\ninstitutional and industrial boilers. In addition, the technician shall have demonstrated\nexperience in conducting equipment inspection and performing testing in compliance\nwith the VA safety testing manual at three (3) or more VA facilities within the past three\n(3) years.\n\nTechnicians shall demonstrate familiarity with and ready access to the current versions of the following references:\n\nNFPA 85, Boiler and Combustion Systems Hazard Code, latest edition.\n\nVHA Boiler Plant Safety Device Testing Manual, current edition.\n\nTerms:\n\nStationary Engineer A stationary engineer, often referred to as a boiler operator or power engineer, is responsible for the operation, maintenance, and repair of stationary engines, boilers, and other mechanical equipment that provide utilities (such as heating, cooling, and power) to buildings, industrial plants, and other facilities. Technician should be qualified in several different makes and models of boiler equipment. Technician should be able to inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may need repair. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nBoiler Technician: A boiler technician will be responsible for adhering to the preventative maintenance program described in the local SOP and superseded by directive 1810. All safety device testing will be in accordance with the United States Department of Veterans Affairs VHA Boiler and Associated Plant Safety Device Testing Manual, current edition. Technicians should be qualified or its equivalent to boiler WG-5402 series as described in the OPM guidelines. Technicians should be able to diagnose, troubleshoot, repair and inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may be required. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nQualified Professional Inspector: A Qualified Professional Inspector is any one or combination of:\na. A boiler inspector who has a valid certificate from the National Board of Boiler and Pressure Vessel Inspectors.\nb. A boiler inspector who has qualified by passing a written examination under the laws, rules and regulations of the State of Maryland.\nc. A boiler inspector who is regularly employed as a boiler inspector/testing by a\njurisdiction that has adopted and administers one or more sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the AMSE Conference\nCommittee.\nd. A boiler inspector who is regularly employed by an insurance company that has been licensed or registered by the appropriate authority of a state of the United States to write boiler and pressure vessel insurance.\n\nThe contractor must provide a list of three (3) reference contacts that have been provided\nservice on similar or identical equipment. The contractor must provide authenticated\nfactory training certificates or credentials (or acceptable substitute as approved by the\nCOR) for any personnel who are working on any VA equipment. The VA specifically\nreserves the right to reject any of the contractor s personnel and refuse them permission\nto work on VA equipment.\n\nAreas to be maintained:\nLoch Raven Rehabilitation & Medical Center is located at 3900 Loch Raven Boulevard, Baltimore MD, 21218 all boiler rooms.\n\nLoch Raven\nEquipment Model Model # Fuel# Location\nBoiler\nCleaver Brooks\nOLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nCleaver Brooks\nOLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nLochinvar\nCBN215\nNatural Gas\nBldg #2 Rear Maintenance Room\nBoiler\nPatterson Kelly\nSC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\nPatterson Kelly\nSC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\nA.O. Smith\n19-4\nNatural Gas\nBldg #5 Boiler Room #1\nBoiler\nSolaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\nSolaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\nWel Mclain\nEG-75\nNatural Gas\nBldg #6 Radiology\nBoiler\nLAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\nLAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\nPatterson Kelly\nSC-1000\nDual Fuel\nBldg #7 Boiler Room\n\nPreventive maintenance breakdown\nThe Contractor shall provide all personnel, management, material, parts, equipment, supplies,\nand labor to perform: Annual inspection, preventive maintenance, and repairs on eleven (12) hot water boilers located at the Loch Raven VAMC. The inspection, maintenance, and repairs shall be performed by qualified boiler technicians. The contractor will perform all preventive\nmaintenance service and functional test to ensure that the equipment performs in compliance\nwith manufacturers operating and maintenance instructions. A written service report will provide a detailed description of work performed and cost, which includes an itemized\nbreakdown for labor, hours, parts, material, and warranty information.\n\nInspection and testing frequency chart:\n\n#\nItem\nFrequency\nNote\n1\nInspect furnace and other internal surfaces, closures and accessories\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n2\nInspect exterior of unit, casing, supports, closures, accessories, valves, controls\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n3\nCheck all boilers for fouling and\ncombustion gas flow\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n4\nTube leak check\nYearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n5\nAdjust burner combustion settings and\ncalibrate oxygen trim\n6 Month\n\n6\nCheck vibration of burner fans\n6 Month\n\n7\nCalibrate instrumentation, monitoring, and control systems\n6 Month\n\n8\nCalibrate pressure gauges and\nthermometers\n6 Month\n\n9\nOperational test of Safety Devices\n6 Month\n\na.\nLow-water cutoff (slow drain)\nMonthly\n\nb.\nFire each boiler and the pilot on the alternate fuel for 1 hour\nMonthly\n\nc.\nLow water cut off\nMonthly\n\nd.\nAuxiliary low water cut off (slow drain)\nMonthly\n\ne.\nHigh water alarm\nMonthly\n\nf.\nLow water alarm\nMonthly\n\ng.\nWater safety valves\nYearly\n\nh.\nWater safety valve operational test\n6 Month\n\ni.\nFlame scanner\nMonthly\n\nj.\nCheck gas vent valve for leaks\n6 Month\n\nk.\nHigh gas fuel pressure cut off\n6 Month\n\nl.\nLow gas fuel pressure cut off\n6 Month\n\nm.\nGas fuel safety shut off valves proof of closure\n6 Month\n\nn.\nLeak test gas fuel safety shut off valves\n6 Month\n\no.\nLow atomizing pressure for fuel oil\n6 Month\n*Building 1 boilers only\np.\nHigh fuel oil pressure cut off\n6 Month\n*Building 1 boilers only\nq.\nFuel oil safety shut off valves proof of closure\n6 Month\n*Building 1 boilers only\nr.\nLeak test fuel oil safety shut off valves\n6 Month\n*Building 1 boilers only\ns.\nCheck operation of liquid petroleum gas pilot\n6 Month\n*Building 1 boilers only\nt.\nLow pilot gas pressure cut out\n6 Month\n\nu.\nForced draft fan motor interlock\n6 Month\n\nv.\nForced draft fan damper wide open for purge\n6 Month\n\nw.\nBoiler outlet damper wide open for purge\n6 Month\n\nx.\nPurge air flow interlock\n6 Month\n\ny.\nTiming for pre-purge\n6 Month\n\nz.\nTiming for post purge\n6 Month\n\naa.\nIgniter timing\n6 Month\n\nbb.\nLow fire position interlock\n6 Month\n\ncc.\nCombustion air interlock\n6 Month\n\ndd.\nMain flame out; i.e. time to close valves\n6 Month\n\nee.\nIgnition flame out; i.e. time to close valves\n6 Month\n\nff.\nMinimum igniter flame test\n6 Month\n\ngg.\nScanner not sensing ignition spark\n6 Month\n\nhh.\nLow oxygen alarm and/or cut out\n6 Month\n\nii.\nPre-purge setting of flue gas recirculation damper\n6 Month\n\njj.\nInterlock of building outside air damper\n6 Month\n\nkk.\nBurner/heating element control\n6 Month\n\nll.\nCO and combustion gas detection equipment testing\n6 Month\n\nmm.\nBoiler emergency button testing\n6 Month\n\nContractor shall document all Preventative Maintenance in the binder provided by COR. Documentation will be in accordance with Loch Raven Boiler SOP & VHA Boiler Plant Safety Device Testing Manual, current edition. Quality control and Contractor leadership shall ensure the documentation is correct and accurate before turning in to COR.\n\nAnnual Maintenance/Operational Maintenance\nA. Monthly\na. Test and adjust water treatment\nb. Operate all alarm devices\nB. Semi-Annual\na. Check furnace pressure\nb. Check combustion gas leaks into boiler room\nC. Annual\na. Open Boilers\nb. Clean waterside of boilers\nc. Clean fireside and repair refractory\n\nRepairs\nA. All repairs to boilers and pressure vessels shall comply with the American Society of\nMechanical Engineers (ASME) Boiler and Pressure Vessel Code. No welded repairs are\npermitted except by certified welders using Code-approved procedures. Repair and\nrecord of certification, and the qualification of welders must be provided to the COR\nupon completion of all repairs. Bids will be adjusted at a flat rate to include $100,000 at the base of the contract to account for emergency repairs annually. This emergency repair cost will be added to the estimated annual preventative maintenance cost. Additional funding may be required for additional repairs.\n\nB. Hydrostatic testing of boilers and pressure vessels must be conducted after a repair\nor a tube replacement, or when the boiler or pressure vessel integrity is in doubt.\nHydrostatic pressure must be limited to 150 percent of normal operating pressure of\nthe boiler or pressure vessel.\n\nInspection, Testing and Calibration Requirements:\nA. Technicians shall provide all tools and labor necessary to perform inspection,\ntuning, testing, calibrating, and adjustments of burners and boiler controls as\nspecified below. This shall be done in accordance with the schedule listed below.\n\nB. Instrumentation, monitoring and data management systems as listed below shall be calibrated every six months. Calibration shall follow VHA Boiler Plant Safety Device Testing Manual, current edition\n\nC. Provide at least two weeks notice to the Contracting Officer s Representative\n(COR) prior to performing the work. Work cannot be scheduled during heavy\nheat load periods. Only one boiler at a time can be out of service for the\ninspection, testing and calibration procedures. Work must be conducted when\nthe COR is onsite to monitor the work.\n\nD. VAMC will have the boilers that are to be serviced prepared for technicians upon\ntheir scheduled arrival. This include having the boilers fully warmed and at\nnormal operating temperature/pressure.\n\nE. The inspection, testing and calibration shall comply with:\na. The recommendations and requirements of VHA Boiler Plant Safety\nDevices Testing Manual, current edition.\nb. The written recommendations of the equipment manufacturers.\nc. The requirements and recommendations of NFPA 85, Boiler and\nCombustion Systems Hazards Code, including applicable appendices.\nd. Burner performance requirements in this document.\n\nF. A summary of the work is as follows, the below summary is not inclusive, refer to the inspection/testing frequency:\na. Review boiler log sheets and alarm and trouble reports.\nb. Review records that show combustion (flue gas oxygen and carbon\nmonoxide).\nc. Perform overall visual inspection of systems. Verify that systems comply\nwith referenced codes and VAMC requirements stated in this contract.\nd. Test and record the operation and set points of all burner/boiler safety\ninterlock devices. Refer to list below. Verify that the set points and\noperating points are within approximately 20% of normal operating\nparameters. Make adjustments as necessary and record the new settings.\nThe operation of a device must result in burner shutdown and/or proper\nalarm operation.\ne. Operate burner(s) on each fuel from low fire to high fire and back to low fire in at least six increments and record combustion performance (flue gas oxygen, carbon monoxide, NOx where applicable), fuel train pressures, atomizing train pressures, burner pressures, stack temperatures, boiler load output.\nf. Compare the combustion performance data with VAMC requirements (see\nbelow) and previous readings. If necessary, make adjustments to the fuel\nflow and combustion air controllers, control valves and dampers to obtain\nthe required performance. Record the new performance data.\ng. Verify accuracy of instrumentation listed below. Verify that all devices are\nproperly selected for the application in terms of type, size, set point range,\nperformance, code approval. Calibrate all instruments that are not within\nmanufacturer s specifications for accuracy.\nh. Immediately inform COR of any recommended repairs of modifications.\n\nG. All of interlocks and safety devices to be inspected and tested on each\nboiler/burner/equipment, are contained in the VHA Boiler Plant Safety Device\nTesting Manual, current edition, along with testing procedures.\n\nH. Required burner performance:\na. Turndown (ratio of maximum and minimum firing rates): 10/1 8/1 5/1 4/1\n(Refer to original burner specification).\nb. Achieve, but do not exceed, boiler maximum heat output rating. Measure\nfuel input at minimum and maximum firing rates.\nc. Maximum carbon monoxide: 200 parts per million (ppm)\nd. Maximum NOx: (refer to original burner specification)\ne. Flue gas oxygen: 2.4 4.2%\nf. Flue gas oxygen (low excess air burners): 1.0 2.0%\ng. No visible smoke, except on heavy oil fuel maximum opacity is 20%.\nComply with local emissions regulations.\nh. Flames shall be stable with no pulsations, shall be retained near burner,\nno blow off or flashback, no constant flame impingement on refractory or\nwater walls.\n\nI. List of instrumentation and controls to be inspected and calibrated:\na. Boiler outlet draft controllers\nb. Boiler water level controllers\nc. All pressure and temperature sensors and transmitters\nd. All signal processing and readout devices\n\nJ. Report requirements:\na. Provide complete written report of the inspection fully describing all tests\nperformed, all findings, and recommendations. The report shall have two\nsections the first section will be in a table form with four columns:\ni. The first column labeled FUNCTION with pass or fail\nii. The second column labeled Devices list the device number and\ndescription in accordance with the VHA Boiler Plant Safety Devices\nTesting Manual, current edition.\niii. The third column labeled Deficiencies-Recommendations\niv. The fourth column labeled Corrective Actions list any corrective\nactions taken during the inspection.\nb. Furnish the report within one week of each inspection in Microsoft Word\nformat by email to the COR. Provide hard copies of data sheets and flue\ngas analyzer strip printouts to the COR within one week of visit.\nc. All safety-related deficiencies shall be immediately reported to the COR\nand/or Chief Engineer during the inspection visit.\n\nDocumentation and Policy Review\nContractors will be required to have a kickoff meeting to review 1810 hot water boiler directive & VHA Boiler Plant Safety Devices Testing Manual, current edition. This will be reviewed annually with the COR for any changes.\n\nThe Contractor shall establish and maintain a Quality Control Program that ensures that all\nrequirements of the contract are provided as specified. This individual shal meet with the COR and CO quarterly to update or provide deliverables.\n\nContractor shall provide annual training on all the Boiler Equipment for designated employees\nassigned to the Loch Raven campus (approximately 20 personnel) over two-day, eight (8) hour\ncourses. The training shall be in accordance with the manufacturer s Commissioning and Start\nUp operation manuals. In addition, the training shall cover the following topics:\n\nA. Proper operation of all boilers listed in the scope of work\nB. Hydronic system overview\nC. Maintenance log procedures and regulations\nD. How to recognize failures of expansion tanks, and unsafe conditions\nE. PRV discharge conditions and inspections\nF. Inspection of CO monitors\n\nDocumentation and deliverables shall be provided to COR. Signed and dated documents will be filed annually for training. Contractor to provide date of draining 30 days in advance to the federal government.\n\nHours of operation & Reporting for Duty: Contractor staff shall report for duty to the designated locations for each campus to be established by the Contracting Officer Representative (COR). The contractors shall review the required tasks and scheduling with the Facilities and Engineering supervisor Point Of Contact (POC) prior to the start of each workday. The workday hours shall be coordinated with the COR but will generally be an 8-hour day beginning at 8:00am. Hours may be adjusted/flexed to fit each campus need. This will be determined by the COR and be presented in written format for any schedule changes. Schedules shall be made to meet boiler preventative maintenance requirements.\n\nReporting Requirements: Upon completion of work, the Contractor shall document services electronically or written in a legible format and provide to the COR. If services are performed after normal businesses hours, the Contractor shall report to the VA site manager or designee. Contractor to provide the service report to the COR on the next business day (with the signature of the VA site manager) to substantiate hours work performed.\n\nInvoicing: Contractor to submit invoicing within monthly intervals. Invoicing is to be line itemed and as detailed as possible. Labor hours are to be clearly marked by trade. Items that are not included in afore mentioned services agreement are not to be invoiced through this contract. Invoicing will be reviewed by the Contracting Officer Representative (COR) for authenticity. Items not to be billed to this contract will be equipment damage, storage fees, fuel fees, rental costs, unverified hours, travel cost, additional fees, taxes, etc. Invoices will be rejected and be required to be resubmitted if errors are detected.\n\nOrdering Activities and Officers: The Contractor and/or its staff shall not accept any instructions issued by any other person(s) other than the Contracting Officer, the COR, or his/her delegated representative acting within the limits of his/her authority. Purchase of materials, orders or additional service will be documented and coordinated through the COR.\n\nSafety and Security Precautions:\n\nThe Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety. The requirements include but are not limited to those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926. Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthy working conditions for its employees.\n\nContractor shall provide his/her employees with the necessary safety equipment required for performance of the contract. The contractor shall take precautions regarding fire and safety policies/procedures within VAMC and their associated Clinics.\n\nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\n\nNo flammable liquids shall be stored in non-designated areas or used in the medical center without communication and written approval from the Contracting Officer Representative (COR).\n\nThe Contractor and/or its staff shall immediately notify the COR of any existing or potentially unsafe conditions, i.e., frayed electrical cord, dripping, or seeping of fluids.\n\nThe Contractor shall receive from the COR a permit for all cutting, welding, soldering, or Hot Work of any kind. All permits shall be prominently displayed during all activities.\n\nAll necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads.\n\nHAZARDOUS MATERIAL REPORTING:\nThe Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center. Hazardous materials must be inventoried when received and at the project s completion. The amounts used shall be maintained for the project duration.\n\nHazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative.\n\nIn the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer. The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761.\n\nSmoking Policy: Smoking is not permitted within the VAMC facilities. Smoking is prohibited in building or on the campus grounds. Contractors found smoking in/on campus, their vehicles will be removed from campus and contractors supervision notified.\nService Calls: Contractor s to provide emergency contacts, standard point of contacts name, phone number and email address for contractor POC. This contract is expected to have 24 hour response to boiler failures with a 2 hour window for emergency response to repair.\nChanges. Only those services specified herein are authorized. Services that are not included in the contract shall NOT be provided unless authorized via a modification issued by the Contracting Officer.\nOvertime: Overtime or evening rates shall be approved by the COR or his/her designated representative prior to services being rendered.\nBadges and Parking: Contractor personnel are required to wear identification (I. D.) badges issued by the VA Security Office during the entire time they are on the grounds of the VAMC or one of its clinics.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the VAMC Security Office. The Government shall not validate or reimburse for parking violations under any circumstance.\nAt the Loch Raven Campus, Contractors will park along the designated contractors parking area The Alameda. Contractors may temporarily park vehicles closer to buildings for drop off purposes that do not exceed 30 minutes per day unless otherwise discussed with the COR. Contractors may not offload and leave vehicles in the loading dock location, blocking rear building entrances or in fire lanes.\n\nNational Holidays: Listed below are the eleven national holidays:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nAlso included would be any day specifically declared by the President of the United States of America as a National holiday.\n\nPoint of Contact and COR:\nAll questions, clarifications, or ambiguities must be in writing to:\nLouis Hopson Louis.Hopson@va.gov\n3900 Loch Raven Blvd 443-986-2593\nBaltimore, MD 21218\n(410) 605-7000 x55889","html":"Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Loch Raven VA Medical Center.\n\nPlease respond to this RFI/Sources Sought 36C24526Q0027 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, \nDisadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing these types of \nservices for the Veterans Health Administration or other similar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include \napplicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide these \nservices at the Huntington VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet the \nperformance requirements while complying with applicable limitations in \nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\nResponses must be received by Thursday 10/09/ 2026 @ 11:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov \n\n\nLoch Raven Boiler Preventative Maintenance Contract \n\nLoch Raven VAMC\n\n\n\n\n\nGeneral: \nVISN 5 The VA Maryland Health Care System is dedicated to improving the lives of Veterans and their families every day. Our health care teams are deeply experienced and guided by the needs of Veterans, their families, and caregivers. The Loch Raven medical center boiler program is comprised of 12 decentralized boilers across 7 buildings. The proposed contract will improve preventative maintenance, inspections and service maintenance to this equipment. Preventative maintenance involvesÂ functional checks, servicing, repairing, or replacing of necessary parts for all boilers on campus. These cost-effective practices keep equipment operational and running smoothly, reducing down time extending operating life and decreasing impact to patients. \n\nAbout the sites:\n\nTheÂ Loch Raven VA Community Living & Rehabilitation Center Provides rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s. The surrounding campus provides services including mental health care, audiology, care for Veterans who are blind or have low vision, and more.\n\n\n                                            \nPlanned preventative maintenance, which is scheduled maintenance aimed at making repairs BEFORE failure occurs. Tasks like cleaning equipment or replacing air/water filters represent a form of routine preventative maintenance because there is a set cadence that occurs regularly regardless of how the equipment is running. Here, you're preventing it from breaking down or running inefficiently.\nPlanned unscheduled maintenance, which is having a strategy in place to repair or replace an asset as quickly as possible when it fails. Replacing and/or repairing gaskets or a compressor can be considered unscheduled because it usually occurs on an as-needed basis whenever wear is present or the unit breaks down. This situation can also incorporate a planning element by either having real OEM replacement parts on hand or budgeting for the cost of repairing/replacing a failed part.\n\n\n\n\nCONTRACTOR PERSONNEL\n\nA. Technician Qualifications. All work shall be performed by qualified boiler technicians,\nexperienced and qualified to work on the specific makes and models of equipment listed\nin this contract. The Contractor shall submit to and for the approval of the Contracting\nOfficer, certification and a list of credentials of the qualified boiler technicians.\nTechnicians shall have completed at least a one-year trade school and have a minimum of\nfive (5) years successful experience in the field. The experience shall be largely with\ninstitutional and industrial boilers. In addition, the technician shall have demonstrated\nexperience in conducting equipment inspection and performing testing in compliance\nwith the VA safety testing manual at three (3) or more VA facilities within the past three\n(3) years.\n\nTechnicians shall demonstrate familiarity with and ready access to the current versions of the following references: \n\nNFPA 85, Boiler and Combustion Systems Hazard Code, latest edition.\n\nVHA Boiler Plant Safety Device Testing Manual, current edition.\n\n\nTerms:\n\nStationary Engineer A stationary engineer, often referred to as a boiler operator or power engineer, is responsible for the operation, maintenance, and repair of stationary engines, boilers, and other mechanical equipment that provide utilities (such as heating, cooling, and power) to buildings, industrial plants, and other facilities. Technician should be qualified in several different makes and models of boiler equipment. Technician should be able to inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may need repair. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nBoiler Technician: A boiler technician will be responsible for adhering to the preventative maintenance program described in the local SOP and superseded by directive 1810. All safety device testing will be in accordance with the United States Department of Veterans Affairs VHA Boiler and Associated Plant Safety Device Testing Manual, current edition. Technicians should be qualified or its equivalent to boiler WG-5402 series as described in the OPM guidelines. Technicians should be able to diagnose, troubleshoot, repair and inform the agency of eminent equipment failure, dangerous conditions and future maintenance work that may be required. Maintain clean and organized work areas. Provide equipment and materials to adhere with Infection Control Risk Assessment (ICRA) standards.\n\nQualified Professional Inspector: A Qualified Professional Inspector is any one or combination of:\na. A boiler inspector who has a valid certificate from the National Board of Boiler and Pressure Vessel Inspectors.\nb. A boiler inspector who has qualified by passing a written examination under the laws, rules and regulations of the State of Maryland.\nc. A boiler inspector who is regularly employed as a boiler inspector/testing by a\njurisdiction that has adopted and administers one or more sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code as a legal requirement, and has a representative serving as a member of the AMSE Conference\nCommittee.\nd. A boiler inspector who is regularly employed by an insurance company that has been licensed or registered by the appropriate authority of a state of the United States to write boiler and pressure vessel insurance.\n\nThe contractor must provide a list of three (3) reference contacts that have been provided\nservice on similar or identical equipment. The contractor must provide authenticated\nfactory training certificates or credentials (or acceptable substitute as approved by the\nCOR) for any personnel who are working on any VA equipment. The VA specifically\nreserves the right to reject any of the contractor s personnel and refuse them permission\nto work on VA equipment.\n\n\nAreas to be maintained:\nLoch Raven Rehabilitation & Medical Center is located at 3900 Loch Raven Boulevard, Baltimore MD, 21218 all boiler rooms.  \n\n\nLoch Raven\nEquipment     Model                Model #               Fuel#                Location\nBoiler\nCleaver Brooks\n        OLO94490 CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nCleaver Brooks\n        OLO94490     CB200-060-030HW\nDual Fuel\nBldg #1 Basement G-19\nBoiler\nLochinvar\n       CBN215 \nNatural Gas\nBldg #2 Rear Maintenance Room\nBoiler\n    Patterson Kelly\n       SC-1000 \nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\n           Patterson Kelly \n       SC-1000\nNatural Gas\nBldg #4 Basement boiler Room\nBoiler\n               A.O. Smith\n            19-4\nNatural Gas\nBldg #5 Boiler Room #1\nBoiler\n                  Solaris\n     SOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\n   Solaris\nSOLO500BNB-cafm\nNatural Gas\nBldg #5 Boiler Room #2\nBoiler\n              Wel Mclain \n         EG-75\nNatural Gas\nBldg #6 Radiology\nBoiler\n                  LAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\n                  LAARS\nPNCH1000NACN2CJX\nNatural Gas\nBldg #7 Boiler Room\nBoiler\n     Patterson Kelly\n        SC-1000\nDual Fuel\nBldg #7 Boiler Room\n\n\nPreventive maintenance breakdown\nThe Contractor shall provide all personnel, management, material, parts, equipment, supplies,\nand labor to perform: Annual inspection, preventive maintenance, and repairs on eleven (12) hot water boilers located at the Loch Raven VAMC. The inspection, maintenance, and repairs shall be performed by qualified boiler technicians. The contractor will perform all preventive\nmaintenance service and functional test to ensure that the equipment performs in compliance\nwith manufacturers operating and maintenance instructions. A written service report will provide a detailed description of work performed and cost, which includes an itemized\nbreakdown for labor, hours, parts, material, and warranty information.\n\nInspection and testing frequency chart:\n\n#\nItem\n        Frequency\n       Note\n1\nInspect furnace and other internal surfaces, closures and accessories\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n2\nInspect exterior of unit, casing, supports, closures, accessories, valves, controls\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n3\nCheck all boilers for fouling and\ncombustion gas flow\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n4\nTube leak check\n           Yearly\n*Must be\naccomplished by a\ndocumented\nqualified third party\nprofessional\ninspector\n5\nAdjust burner combustion settings and\ncalibrate oxygen trim\n        6 Month\n\n6\nCheck vibration of burner fans\n        6 Month\n\n7\nCalibrate instrumentation, monitoring, and control systems\n        6 Month\n\n8\nCalibrate pressure gauges and\nthermometers\n        6 Month\n\n9\nOperational test of Safety Devices\n        6 Month\n\na.\nLow-water cutoff (slow drain)\n        Monthly\n\nb.\nFire each boiler and the pilot on the alternate fuel for 1 hour\n        Monthly\n\nc.\nLow water cut off\n        Monthly\n\nd.\nAuxiliary low water cut off (slow drain)\n        Monthly\n\ne.\nHigh water alarm\n        Monthly\n\nf.\nLow water alarm\n         Monthly\n\ng.\nWater safety valves\n        Yearly\n\nh.\nWater safety valve operational test\n        6 Month\n\ni.\nFlame scanner\n          Monthly\n\nj.\nCheck gas vent valve for leaks\n        6 Month\n\nk.\nHigh gas fuel pressure cut off\n        6 Month\n\nl.\nLow gas fuel pressure cut off\n        6 Month\n\nm.\nGas fuel safety shut off valves proof of closure\n        6 Month\n\nn.\nLeak test gas fuel safety shut off valves\n        6 Month\n\no.\nLow atomizing pressure for fuel oil\n        6 Month\n*Building 1 boilers only\np.\nHigh fuel oil pressure cut off\n        6 Month\n*Building 1 boilers only\nq.\nFuel oil safety shut off valves proof of closure\n        6 Month\n*Building 1 boilers only\nr.\nLeak test fuel oil safety shut off valves\n        6 Month\n*Building 1 boilers only\ns.\nCheck operation of liquid petroleum gas pilot\n        6 Month\n*Building 1 boilers only\nt.\nLow pilot gas pressure cut out\n        6 Month\n\nu.\nForced draft fan motor interlock\n        6 Month\n\nv.\nForced draft fan damper wide open for purge\n        6 Month\n\nw.\nBoiler outlet damper wide open for purge\n        6 Month\n\nx.\nPurge air flow interlock\n        6 Month\n\ny.\nTiming for pre-purge\n        6 Month\n\nz.\nTiming for post   purge\n        6 Month\n\naa.\nIgniter timing\n        6 Month\n\nbb.\nLow fire position interlock\n        6 Month\n\ncc.\nCombustion air interlock\n        6 Month\n\ndd.\nMain flame out; i.e. time to close valves\n        6 Month\n\nee.\nIgnition flame out; i.e. time to close valves\n        6 Month\n\nff.\nMinimum igniter flame test\n        6 Month\n\ngg.\nScanner not sensing ignition spark\n        6 Month\n\nhh.\nLow oxygen alarm and/or cut out\n        6 Month\n\nii.\nPre-purge setting of flue gas recirculation damper\n        6 Month\n\njj.\nInterlock of building outside air damper\n        6 Month\n\nkk.\nBurner/heating element control\n        6 Month\n\nll.\nCO and combustion gas detection equipment testing\n        6 Month\n\nmm.\nBoiler emergency button testing\n        6 Month\n\n\nContractor shall document all Preventative Maintenance in the binder provided by COR. Documentation will be in accordance with Loch Raven Boiler SOP & VHA Boiler Plant Safety Device Testing Manual, current edition. Quality control and Contractor leadership shall ensure the documentation is correct and accurate before turning in to COR.\n\nAnnual Maintenance/Operational Maintenance\nA. Monthly\na. Test and adjust water treatment\nb. Operate all alarm devices\nB. Semi-Annual\na. Check furnace pressure\nb. Check combustion gas leaks into boiler room\nC. Annual\na. Open Boilers\nb. Clean waterside of boilers\nc. Clean fireside and repair refractory\n\nRepairs\nA. All repairs to boilers and pressure vessels shall comply with the American Society of\nMechanical Engineers (ASME) Boiler and Pressure Vessel Code. No welded repairs are\npermitted except by certified welders using Code-approved procedures. Repair and\nrecord of certification, and the qualification of welders must be provided to the COR\nupon completion of all repairs. Bids will be adjusted at a flat rate to include $100,000 at the base of the contract to account for emergency repairs annually. This emergency repair cost will be added to the estimated annual preventative maintenance cost. Additional funding may be required for additional repairs.\n\nB. Hydrostatic testing of boilers and pressure vessels must be conducted after a repair            \nor a tube replacement, or when the boiler or pressure vessel integrity is in doubt. \nHydrostatic pressure must be limited to 150 percent of normal operating pressure of \nthe boiler or pressure vessel.\n\nInspection, Testing and Calibration Requirements:\nA. Technicians shall provide all tools and labor necessary to perform inspection,\ntuning, testing, calibrating, and adjustments of burners and boiler controls as\nspecified below. This shall be done in accordance with the schedule listed below.\n\nB. Instrumentation, monitoring and data management systems as listed below shall be  calibrated every six months. Calibration shall follow VHA Boiler Plant Safety Device Testing Manual, current edition\n\nC. Provide at least two weeks  notice to the Contracting Officer s Representative\n(COR) prior to performing the work. Work cannot be scheduled during heavy\nheat load periods. Only one boiler at a time can be out of service for the\ninspection, testing and calibration procedures. Work must be conducted when\nthe COR is onsite to monitor the work.\n\nD. VAMC will have the boilers that are to be serviced prepared for technicians upon\ntheir scheduled arrival. This include having the boilers fully warmed and at\nnormal operating temperature/pressure.\n\nE. The inspection, testing and calibration shall comply with:\na. The recommendations and requirements of VHA Boiler Plant Safety\nDevices Testing Manual, current edition.\nb. The written recommendations of the equipment manufacturers.\nc. The requirements and recommendations of NFPA 85, Boiler and\nCombustion Systems Hazards Code, including applicable appendices.\nd. Burner performance requirements in this document.\n\nF. A summary of the work is as follows, the below summary is not inclusive, refer to the inspection/testing frequency:\na. Review boiler log sheets and alarm and trouble reports.\nb. Review records that show combustion (flue gas oxygen and carbon\nmonoxide).\nc. Perform overall visual inspection of systems. Verify that systems comply\nwith referenced codes and VAMC requirements stated in this contract.\nd. Test and record the operation and set points of all burner/boiler safety\ninterlock devices. Refer to list below. Verify that the set points and\noperating points are within approximately 20% of normal operating\nparameters. Make adjustments as necessary and record the new settings.\nThe operation of a device must result in burner shutdown and/or proper\nalarm operation.\ne. Operate burner(s) on each fuel from low fire to high fire and back to low fire in at least six increments and record combustion performance (flue gas oxygen, carbon monoxide, NOx where applicable), fuel train pressures, atomizing train pressures, burner pressures, stack temperatures, boiler load output.\nf. Compare the combustion performance data with VAMC requirements (see\nbelow) and previous readings. If necessary, make adjustments to the fuel\nflow and combustion air controllers, control valves and dampers to obtain\nthe required performance. Record the new performance data.\ng. Verify accuracy of instrumentation listed below. Verify that all devices are\nproperly selected for the application in terms of type, size, set point range,\nperformance, code approval. Calibrate all instruments that are not within\nmanufacturer s specifications for accuracy.\nh. Immediately inform COR of any recommended repairs of modifications.\n\nG. All of interlocks and safety devices to be inspected and tested on each\nboiler/burner/equipment, are contained in the VHA Boiler Plant Safety Device\nTesting Manual, current edition, along with testing procedures.\n\nH.  Required burner performance:\na. Turndown (ratio of maximum and minimum firing rates): 10/1 8/1 5/1 4/1\n(Refer to original burner specification).\nb. Achieve, but do not exceed, boiler maximum heat output rating. Measure\nfuel input at minimum and maximum firing rates.\nc. Maximum carbon monoxide: 200 parts per million (ppm)\nd. Maximum NOx: (refer to original burner specification)\ne. Flue gas oxygen: 2.4   4.2%\nf. Flue gas oxygen (low excess air burners): 1.0   2.0%\ng. No visible smoke, except on heavy oil fuel maximum opacity is 20%.\nComply with local emissions regulations.\nh.  Flames shall be stable with no pulsations, shall be retained near burner,\nno blow off or flashback, no constant flame impingement on refractory or\nwater walls.\n\nI. List of instrumentation and controls to be inspected and calibrated:\na. Boiler outlet draft controllers\nb. Boiler water level controllers\nc. All pressure and temperature sensors and transmitters\nd. All signal processing and readout devices\n\nJ. Report requirements:\na. Provide complete written report of the inspection fully describing all tests\nperformed, all findings, and recommendations. The report shall have two\nsections the first section will be in a table form with four columns:\ni. The first column labeled  FUNCTION  with pass or fail\nii. The second column labeled  Devices  list the device number and\ndescription in accordance with the VHA Boiler Plant Safety Devices\nTesting Manual, current edition.\niii. The third column labeled  Deficiencies-Recommendations \niv. The fourth column labeled  Corrective Actions  list any corrective\nactions taken during the inspection.\nb. Furnish the report within one week of each inspection in  Microsoft Word \nformat by email to the COR. Provide hard copies of data sheets and flue\ngas analyzer  strip  printouts to the COR within one week of visit.\nc. All safety-related deficiencies shall be immediately reported to the COR\nand/or Chief Engineer during the inspection visit.\n\n\n\nDocumentation and Policy Review\nContractors will be required to have a kickoff meeting to review 1810 hot water boiler directive & VHA Boiler Plant Safety Devices Testing Manual, current edition. This will be reviewed annually with the COR for any changes.\n\nThe Contractor shall establish and maintain a Quality Control Program that ensures that all\nrequirements of the contract are provided as specified. This individual shal meet with the COR and CO quarterly to update or provide deliverables.\n\nContractor shall provide annual training on all the Boiler Equipment for designated employees\nassigned to the Loch Raven campus (approximately 20 personnel) over two-day, eight (8) hour\ncourses. The training shall be in accordance with the manufacturer s  Commissioning and Start\nUp  operation manuals. In addition, the training shall cover the following topics:\n\nA. Proper operation of all boilers listed in the scope of work\nB. Hydronic system overview\nC. Maintenance log procedures and regulations\nD. How to recognize failures of expansion tanks, and unsafe conditions\nE. PRV discharge conditions and inspections\nF. Inspection of CO monitors\n\nDocumentation and deliverables shall be provided to COR. Signed and dated documents will be filed annually for training. Contractor to provide date of draining 30 days in advance to the federal government.\n\nHours of operation & Reporting for Duty: Contractor staff shall report for duty to the designated locations for each campus to be established by the Contracting Officer Representative (COR). The contractors shall review the required tasks and scheduling with the Facilities and Engineering supervisor Point Of Contact (POC) prior to the start of each workday. The workday hours shall be coordinated with the COR but will generally be an 8-hour day beginning at 8:00am. Hours may be adjusted/flexed to fit each campus  need. This will be determined by the COR and be presented in written format for any schedule changes. Schedules shall be made to meet boiler preventative maintenance requirements.\n\nReporting Requirements: Upon completion of work, the Contractor shall document services electronically or written in a legible format and provide to the COR. If services are performed after normal businesses hours, the Contractor shall report to the VA site manager or designee. Contractor to provide the service report to the COR on the next business day (with the signature of the VA site manager) to substantiate hours work performed.\n\nInvoicing: Contractor to submit invoicing within monthly intervals. Invoicing is to be line itemed and as detailed as possible. Labor hours are to be clearly marked by trade. Items that are not included in afore mentioned services agreement are not to be invoiced through this contract. Invoicing will be reviewed by the Contracting Officer Representative (COR) for authenticity. Items not to be billed to this contract will be equipment damage, storage fees, fuel fees, rental costs, unverified hours, travel cost, additional fees, taxes, etc. Invoices will be rejected and be required to be resubmitted if errors are detected. \n\nOrdering Activities and Officers: The Contractor and/or its staff shall not accept any instructions issued by any other person(s) other than the Contracting Officer, the COR, or his/her delegated representative acting within the limits of his/her authority. Purchase of materials, orders or additional service will be documented and coordinated through the COR.\n\nSafety and Security Precautions:\n\nThe Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety.  The requirements include but are not limited to those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926.  Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthy working conditions for its employees.\n\nContractor shall provide his/her employees with the necessary safety equipment required for performance of the contract. The contractor shall take precautions regarding fire and safety policies/procedures within VAMC and their associated Clinics. \n\nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\n\nNo flammable liquids shall be stored in non-designated areas or used in the medical center without communication and written approval from the Contracting Officer Representative (COR). \n\nThe Contractor and/or its staff shall immediately notify the COR of any existing or potentially unsafe conditions, i.e., frayed electrical cord, dripping, or seeping of fluids. \n\nThe Contractor shall receive from the COR a permit for all cutting, welding, soldering, or  Hot Work  of any kind. All permits shall be prominently displayed during all activities. \n\nAll necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads.\n\nHAZARDOUS MATERIAL REPORTING: \nThe Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center.  Hazardous materials must be inventoried when received and at the project s completion.  The amounts used shall be maintained for the project duration. \n  \nHazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative.\n\nIn the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer.  The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761. \n\nSmoking Policy: Smoking is not permitted within the VAMC facilities. Smoking is prohibited in building or on the campus grounds. Contractors found smoking in/on campus, their vehicles will be removed from campus and contractors supervision notified.\nService Calls: Contractor s to provide emergency contacts, standard point of contacts name, phone number and email address for contractor POC. This contract is expected to have 24 hour response to boiler failures with a 2 hour window for emergency response to repair.\nChanges. Only those services specified herein are authorized. Services that are not included in the contract shall NOT be provided unless authorized via a modification issued by the Contracting Officer.  \nOvertime: Overtime or evening rates shall be approved by the COR or his/her designated representative prior to services being rendered.\nBadges and Parking: Contractor personnel are required to wear identification (I. D.) badges issued by the VA Security Office during the entire time they are on the grounds of the VAMC or one of its clinics. \nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the VAMC Security Office. The Government shall not validate or reimburse for parking violations under any circumstance. \nAt the Loch Raven Campus, Contractors will park along the designated contractors parking area The Alameda. Contractors may temporarily park vehicles closer to buildings for  drop off  purposes that do not exceed 30 minutes per day unless otherwise discussed with the COR. Contractors may not offload and leave vehicles in the loading dock location, blocking rear building entrances or in fire lanes.\n\nNational Holidays:  Listed below are the eleven national holidays:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day \nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day \nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day \nSecond Monday in October\nVeterans Day \nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nAlso included would be any day specifically declared by the President of the United States of America as a National holiday.\n\n\nPoint of Contact and COR:\nAll questions, clarifications, or ambiguities must be in writing to:\n Louis Hopson  Louis.Hopson@va.gov \n 3900 Loch Raven Blvd    443-986-2593\n Baltimore, MD  21218\n (410) 605-7000 x55889","origin":"detail"},"contacts":[{"name":"William Chris Galletta","role":"primary","email":"William.Galletta@va.gov","phone":"410-637-1506","title":"Contracting Officer"}],"place_of_performance":{"zip":"21218","city":{"name":"Baltimore"},"state":{"name":"MD"},"street":"Department of Veterans Affairs Loch Raven VAMC","street2":"3901 Loch Raven Blvd."},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"02193468bf6b48a6a01350823fce6867","name":"36C24526Q0027.docx","kind":"file","mime_type":".docx","size_bytes":52245,"posted_at":"2025-09-25T17:10:07.618Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/02193468bf6b48a6a01350823fce6867/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"140FF027Q0080","latest_notice_id":"c706d18cc5e846508a63090d29caa934","title":"AK-AK MARITIME NWR-LEAK REPAIR","solicitation_number":"140FF027Q0080","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140FF0","office_name":"FWS CONTRACTING ACTIVITY","naics":"238220","psc":"J045","set_aside":"SBA","state":"AK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"title","state_evidence":"AK-A","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open_total":57,"indexable":false}