{"canonical":"https://sealedbidder.com/opportunities/36c24525q0588","key":"36C24525Q0588","url":"https://sealedbidder.com/opportunities/36c24525q0588","title":"4110--Walk-In Coolers & Freezers","solicitation_number":"36C24525Q0588","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-27T16:00:00Z","first_posted":"2025-06-16","last_posted":"2025-06-16","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"333415","psc":"4110","set_aside":null,"place_state":"WV","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"54033","place_county_name":"Harrison County","place_city":"5415628","place_city_name":"Clarksburg","winner":null,"award_amount":null,"publications":[{"notice_id":"7f231a2a33be4db9b79a10e271bbe9b9","title":"4110--Walk-In Coolers & Freezers","solicitation_number":"36C24525Q0588","notice_type":"r","base_type":"r","posted":"2025-06-16","posted_at":"2025-06-16T18:50:18.129Z","due_at":"2025-06-27T16:00:00Z","due_date":"2025-06-27","cancelled":false,"archived":true,"archive_date":"2025-07-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7f231a2a33be4db9b79a10e271bbe9b9/view","enriched":true,"history":[{"index":3,"title":"4110--Walk-In Coolers & Freezers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-16T18:50:18.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7f231a2a33be4db9b79a10e271bbe9b9","solicitation_number":"36C24525Q0588"}]}],"latest_notice_id":"7f231a2a33be4db9b79a10e271bbe9b9","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-16","posted_at":"2025-06-16T18:50:18.129Z","created_at":"2025-06-16T18:49:42.880Z","modified_at":"2025-07-04T04:04:28.423Z","response_deadline":{"raw":"2025-06-27T12:00:00-04:00","utc":"2025-06-27T16:00:00Z","date":"2025-06-27","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7f231a2a33be4db9b79a10e271bbe9b9/view"},"naics":{"codes":["333415"],"primary":"333415"},"title":"4110--Walk-In Coolers & Freezers","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-04","archive_type":"auto_custom"},"history":[{"index":3,"title":"4110--Walk-In Coolers & Freezers","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-16T18:50:18.129Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7f231a2a33be4db9b79a10e271bbe9b9","solicitation_number":"36C24525Q0588"}],"contacts":[{"name":"Phillip G Duba","role":"primary","email":"Phillip.Duba@va.gov","phone":"EMAIL ONLY - NO TELEPHONE CALL","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"7f231a2a33be4db9b79a10e271bbe9b9","lineage_id":"7f231a2a33be4db9b79a10e271bbe9b9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T12:43:25.697783282Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"28e6efe9d904ff907ddf82589aa0a65bcd96db046383668ceb6da089b0bb4588","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T12:43:25.697783282Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"RFI 36C24525Q0588\nWALK-IN FREEZERS-COOLERS\n\nTHIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought/RFI/RFI only.  The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 333415 (1,250 Employes). Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published.  Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.  \nThe Department of Veterans Affairs (VA), VISN 5 Martinsburg Network Contracting Office, is seeking sources who can possibly provide Walk In Freezers & Coolers for the Louis A Johnson VA Medical Center, Clarksburg, WV  26301.\nIt is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. \nIf you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) Are you the manufacturer, authorized distributor, and/or can you provide equivalent solution to the items being referenced above?\n(4) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(6) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in FAR 19.505? Specifically, what percentage of the work will be performed by your company versus subcontractors?\n(7) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items\n(8) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Take ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice?\n(9) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(10) Please complete FAR 52.225-2 below.\n(11) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(12) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solution you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(13) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(14) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics or  equal to items  for planning purposes; show clear, compelling and convincing evidence that all  equal to items\" meet all the salient characteristics.\n(15) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(16) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Phillip.Duba@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Friday, June 27, 2025 by 12:00 PM EST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement. \nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\n\nStatement of Work\nVA Clarksburg\n\nGENERAL SPECIFICATIONS FOR WALK-IN COOLERS/FREEZERS \nBackground\nThe Louis A. Johnson VAMC is executing contract # 36C24521C0034, VA Project No. 540-370. The project includes renovation of the kitchen area of the hospital and will require the purchase of Walk-In coolers and Freezers equal to the specifications detailed below in salient characteristics.\nSpecifications\nPlease see below for salient characteristics.  \nGeneral Description\nPrefabricated, sectional, all-metal clad, modular, and designed for easy accurate field assembly.  Walk-In units must be for food service use conforming to NSF/ANSI 7, UL 207 and UL 471.  Floor panel with appropriate insulated floor assembly and aluminum tread finish floor.  See drawings in Section 5 for layout/additional details.\nPanels   General\nInterchangeable, 1219 mm (48 inch) maximum width, 126\nmm (5 inch) thick exterior wall, floor and ceiling panels, and\n101 mm (4 inch) thick interior dividing wall panels between\ncompartments, filled with insulation. Double seal serrated\nneoprene rubber gaskets to assure air and vapor tight joints.\nPanels - Corner\n90-degree angle, radiuses 15 mm (0.5 inch)\ninside and outside, with 305 mm (12-inch) dimensions each\nside.\nPanels - Edges\nFoam-in-place, tongue-and-grooved urethane to\nassure tight joints. Provide double seal serrated neoprene\nrubber gaskets to assure air and vapor tight joints on the\ninterior and exterior of each panel along every tongue.\nInsulation\n127 mm (5 inch) and 101 mm (4 inch) minimum foamed in-\nplace polyurethane per detail drawings with manufacturer s\nrated  K  factor of not more than 0.15, free rise design of\nnot less than 27 kg per cubic meter (1.7 pounds per cubic\nfoot), or in-place density of not less than 32 kg per cubic\nmeter (2 pounds per cubic foot).\n\nDoor Panel and Door\na. Provide channel thermal breaker type reinforcing steel\nframe around the entire perimeter of the door opening.\nb. Door to be an in-fitting flush-mounted type with dual\nflexible blade wiper gasket on the bottom, and a\nreplaceable magnetic gasket on the top edge and along both\nsides.\nc. Provide heated, double glass view windows in refrigerator\ndoors.\nd. Door to be equipped with a minimum of three (3) hinges, for\nrough usage including aluminum diamond plate on inside of\ndoor panel and frame to a height of 915 mm (36 inches).\ne. Provide hydraulic exterior door closer to prevent slamming\nand assure secure closing.\nf. Door hinges and latch and strike assembly: Manufacturer's\nstandard, self-closing cam-lift type hinges, for 1219 mm\n(48 inch) door, chrome plated or polished aluminum finish,\nmade to provide for locking, but with an inside safety\nrelease mechanism to prevent anyone from being locked\ninside when door is locked from outside.\ng. Concealed, energy use selective, anti-sweat heater wire\ncircuit: Provide sufficient heat to prevent condensation\nand frost formation at the door jambs and exterior edges of\nthe door on all sides.\nh. Thermometer: Manufacturer's standard, 50 mm (2-inch)\nminimum diameter, dial type, flush mounted in door panel.\nPressure Relief Port\nProvide for all freezers operating at\n18 degree C (0-degree F), or lower, two-way type ports, to\nallow for an increase or decrease of air pressure on the\ninterior of the freezer to equalize with air pressure on the exterior. Provide ports with automatically controlled, UL\napproved anti-sweat heaters. Complete device to carry UL Label\nand be assembled ready for connection. Install port in a wall\npanel away from the direct air stream flowing from the coils.\nFloor Panels\na. Floor Panel Strength: Capable of withstanding 47.8 kPa (\n1000 pounds per square foot) uniform load.\nb. Provide prefabricated floor panels of the same construction\nas wall/ceiling .100 aluminum diamond treadplate surface\nover 13 mm (.5 inch) marine grade plywood Provide\nprefabricated floor panels which are recessed with, panels\nflush with surrounding building floor. Furnish two (2) sets\nof erection tools, compatible with fasteners, with each unit.\nc. Wherever compartment dimension exceeds clear-span ability of\nceiling panels, provide I-beam support on exterior of ceiling or\nspline-hangers. Install 13 mm (1/2 inch) diameter steel rods\nthrough beam/hangers and secure to structure above. Beams or\nposts within compartments are not acceptable.\nd. Rub rail wall protectors: Manufacturer s standard, at floor line\nof walls exposed to traffic.\nLighting\nLights: Provide high-efficiency rated LED light fixtures with\nsafety shields. Lighting must conform with UL IP-65. Provide with\ndiffuser and be capable of operating in minus 23 degrees C (-40\ndegrees Fahrenheit) temperature. Lights must run length of walkin\nstarting 610 mm (24 inches) from front panel and extending\nwithin 610 mm (24 inches) of back panel. Run between shelf rows\nto obtain 323 lux (30 foot-candles) at floor level regardless of\nany interior furnishings.\nCondensing Units\n Comply with ARI Standard 520. Air cooled, type as shown in construction documents. (See Section 5 Below   Drawings).\nB. Provide motor driven integral compressor, motor starter,\ncondenser, receiver, common base, and safety/operational\ncontrols.\nC. Receiver capacity not to be less than 125 percent of system\nrefrigerant charge.\nD. For units racked above each other and for units installed in a\ncloset, provide a factory fabricated steel rack extending\napproximately 1143 mm (45 inches) above the floor.\nE. Provide two (2) condensing units and unit coolers with\nindependent refrigeration systems for freezer when shown on\nconstruction documents or recommended by manufacturer due to size\nor freezer.\nF. Do not locate compressors on top of refrigerators or freezers.\nG. Provide positive oil lubrication and oil level indicating device\nfor each compressor. Provide water regulating valve for water\ncooled unit.\nH. Compressor Motor: Squirrel cage induction type of ample size for\ncontinuous operating at maximum compressor performance. Provide\ninherent protection, in compressor terminal box, for each phase\nof motor.\nI. Pressure Switches: Automatic reset low pressure switch, and\nautomatic or manual reset high pressure cutout.\nAir Cooled Condensing Units\n1. High efficiency type piped and automatically controlled to\noperate at lower head pressures during low ambient temperature\nconditions. Designed and weather-proofed for outdoor\ninstallation, to operate satisfactorily at winter ambient\ntemperatures down to 6 degrees C (10 degrees F), and be\nprovided with crankcase and receiver heaters.\n2. The condenser fans are to be driven by permanent split\ncapacitor motors.\nUnit Coolers\nA. Comply with ARI Standard 420. Units to be UL listed,\nforced-ventilation type. Provide demand defrost controllers for defrosting, internal or external refrigerant distributor, single\nor multiple fans and motors, drip-pan, deflectors, aluminum or\nbaked-enamel steel housing, hangers, and all accessories. Unit\ncoolers for kitchen walk-in units to be NSF approved.\nB. Motors: Permanent split capacitor type in accordance with\nSection 11 05 12, GENERAL MOTOR REQUIREMENTS FOR EQUIPMENT.\nProvide motors with thermal overload protection and manual\nstarting switch.\nC. Drain Pans: Galvanized sheet steel. Provide additional drain pans\nunder uncovered refrigerant connections, and interconnect them\nwith main drain pan. For freezer units provide electrically\nheated drain pan with heated tape over condensate drain line.\nDefrost Provision\n1. Refrigerators: Defrost to be as needed with Demand defrost\ncontrollers and occur during compressor off cycle with\nevaporator fan running continuously.\n2. Freezer defrost: Defrost to be by demand defrost with Evaporator Efficiency Controller.\nMonitoring Alarm System\nA. Provide an electronic monitoring and alarm system for each\nsection of each unit.\n1. System Components: Detecting thermostat, master control panel,\ninterconnecting wiring, remote audible alarm, and defrost\ncompensator. Provide dials showing temperatures and pilot\nlights, warning lights, switches, transformer, and buzzer, all\nas a part of the master control panel. Locate master control\npanel and remote audible alarm as indicated on construction\ndocuments. Provide power fuse to protect system components.\n2. System Operation: Set alarms at 5 degrees C (10 degrees F)\nabove and below specified operating temperatures.\nB. Personnel Alarm: For each unit, provide separate audible alarm\nsystem operable from inside unit, for use of personnel unable to\nexit unit. Locate remote audible alarm where indicated on\nconstruction documents.\nRefrigeration Rack System\nA. Digital Rack System. Provide two (2) rack systems for Walk-in\ncooler and freezer assembly, item 7. One rack system shall include\nfour (4) compressors, one for each of the four compartments. The\nsecond rack system shall provide duplicate compressors for the\nlarge cooler and large freezer compartments only. The second rack\nsystem shall be designed to alternate running cycles during\nnormal operation and also to allow one compressor set to continue\nto run should the other system have a compressor require service.\nB. The UL-Listed, air-cooled rack systems shall be designed for\noutdoor installation. The units shall be pre-wired for a single\npoint electrical connection with a main fused disconnect. The\nrefrigeration units shall be housed in a weather-protected\ncompact structural galvanized steel frame. The units shall\ninclude individual dedicated air-cooled condensers. Condensers\nshall be aluminum fin/copper tube designed to operate at 15\ndegrees T.D. The exterior housings shall be brushed 304 stainless\nsteel with one-piece stainless-steel lift out louver panels for\neasy access to service. Entire galvanized metal frame shall be\npre-assembled, welded and cleaned. Lifting points shall be\nintegrated in the feet at each corner to facilitate installation.\nCondenser fan motors shall be mounted within the enclosure.\nC. All Primary multiplex compressors shall be digital semi-hermetic\nor scroll type and factory assembled to operate with the\nrefrigerant specified.\nD. All Conventional, stand-by, and/or parallel compressors shall be\nsemi-hermetic or scroll type and factory assembled to operate\nwith specified refrigerant blend.\nE. Compressors and refrigeration piping will be installed in such a\nmanner as to eliminate noise with vibration eliminators in\nrefrigeration lines, as needed. Each compressor unit shall be\nequipped with; oversized receiver, dual pressure control for cut in cut-out, a ball-bearing fan motor, fixed head pressure\ncontrol, suction filter, liquid line sight glass, liquid line\ndrier, crankcase heaters, headmaster controls and/or fan cycling,\nliquid line inlet and outlet valves, defrost cycle and armored\nsuper hose connections (in lieu of capillary tubes).\nF. All refrigerant lines shall be extended to one side of the\npackage in a neat and orderly manner. All tubing shall be\nsecurely supported and anchored with non-corrosive coated clamps.\nAll joints must be brazed, not soldered. All piping and controls\nshall be factory pressure-tested with nitrogen at 175 PSI.\nG. Evaporator coils shall be a direct expansion type. Evaporators\nused will be all \"Underwriters Laboratory Listed\" supplied from\nfactory with an electric expansion valve, solenoid valve, suction\ntransducer, and Eco-Smart on-demand defrost controller, pre-wired\nand pre-piped under nitrogen pressure and designed for use with\nthe refrigerant specified. Isolation ball valves are to be\ninstalled on the liquid and suction lines at each evaporator\ncoil.\n\nWarranty\n\nManufacturer shall agree to repair or replace compressors that fail in materials or workmanship within five (5) years from the date of receipt. Failure includes but is not limited to inability to maintain set temperature.  Walk-in Panels to be warranted for five (5) years.\n\n\n\nPublications\n\nThe publications listed below form a part of this specification to the extent referenced in the salient characteristics.\n\nPublication\nPublication Description\nAir-Conditioning and Refrigeration Institute (ARI) 420-08\nUnit Coolers for Refrigeration\nAir-Conditioning and Refrigeration Institute (ARI) 520-04\nPerformance Rating of Positive\nDisplacement Condensing Units\nAmerican Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 15-10-16\nSafety Standard for Refrigeration Systems\nASTM International (ASTM) A240/A240M-20\nChromium and Chromium-Nickel Stainless\nSteel Plate, Sheet, and Strip for\nPressure Vessels and For General\nApplications\nASTM International (ASTM) E84-20\nSurface Burning Characteristics of Building Materials\nNational Sanitation Foundation/American National Standard\n(NSF/ANSI)7-09\nCommercial Refrigerators and Storage Freezers\nNational Fire Protection Association (NFPA) 70-20\nNational Electric Code\nUnderwriters Laboratories, Inc. (UL) 207-08 (R2014)\nRefrigerant-Containing Components and Accessories, Nonelectrical\nUnderwriters Laboratories, Inc. (UL) 471-10 (R2014)\nCommercial Refrigerators and Freezers\nUnderwriters Laboratories, Inc. (UL) 1598-03 (R2012)\nLuninaires\n\nDrawings\n\n\n\n\nDelivery Location \nAttn: Beth Bova\nBOVA Corporation\n111 McFann Rd\nValencia, PA 16059\nEmail: beth@bovacorp.com \nPhone: (724) 898-0288\n\nPrior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Logistics using the email(s) listed above.\nThe Contractor must comply and provide all necessary information to VA Clarksburg and BOVA Corporation. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. \nRequested Delivery Date\nDelivery of equipment is requested to occur approximately 8-10 weeks ARO (After Receipt of Order).  The typical lead time for this type of equipment is eight (8) weeks.\nSafety Data Sheet (SDS) \n\nIf applicable, contractor shall provide three (3) copies of each Safety Data Sheet for every product, chemical, etc.  SDS sheets shall be provided on the same day those materials arrive at BOVA Corporation.  \nDelivery Coordination\n\nNormal business hours for acceptance of deliveries are 7:30AM   12:00PM and 12:30PM   3:00PM (Eastern Time), Monday thru Friday excluding Holidays.  Deliveries must be coordinated in advance with COR, Service Line Representative and Vendor POC (Beth Bova) once a ship date is established.","text":"RFI 36C24525Q0588\nWALK-IN FREEZERS-COOLERS\n\nTHIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought/RFI/RFI only. The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 333415 (1,250 Employes). Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Martinsburg Network Contracting Office, is seeking sources who can possibly provide Walk In Freezers & Coolers for the Louis A Johnson VA Medical Center, Clarksburg, WV 26301.\nIt is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\nIf you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) Are you the manufacturer, authorized distributor, and/or can you provide equivalent solution to the items being referenced above?\n(4) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(6) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in FAR 19.505? Specifically, what percentage of the work will be performed by your company versus subcontractors?\n(7) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items\n(8) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Take ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice?\n(9) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(10) Please complete FAR 52.225-2 below.\n(11) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(12) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solution you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(13) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(14) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics or equal to items for planning purposes; show clear, compelling and convincing evidence that all equal to items\" meet all the salient characteristics.\n(15) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(16) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Phillip.Duba@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, June 27, 2025 by 12:00 PM EST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement.\nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\n\nStatement of Work\nVA Clarksburg\n\nGENERAL SPECIFICATIONS FOR WALK-IN COOLERS/FREEZERS\nBackground\nThe Louis A. Johnson VAMC is executing contract # 36C24521C0034, VA Project No. 540-370. The project includes renovation of the kitchen area of the hospital and will require the purchase of Walk-In coolers and Freezers equal to the specifications detailed below in salient characteristics.\nSpecifications\nPlease see below for salient characteristics.\nGeneral Description\nPrefabricated, sectional, all-metal clad, modular, and designed for easy accurate field assembly. Walk-In units must be for food service use conforming to NSF/ANSI 7, UL 207 and UL 471. Floor panel with appropriate insulated floor assembly and aluminum tread finish floor. See drawings in Section 5 for layout/additional details.\nPanels General\nInterchangeable, 1219 mm (48 inch) maximum width, 126\nmm (5 inch) thick exterior wall, floor and ceiling panels, and\n101 mm (4 inch) thick interior dividing wall panels between\ncompartments, filled with insulation. Double seal serrated\nneoprene rubber gaskets to assure air and vapor tight joints.\nPanels - Corner\n90-degree angle, radiuses 15 mm (0.5 inch)\ninside and outside, with 305 mm (12-inch) dimensions each\nside.\nPanels - Edges\nFoam-in-place, tongue-and-grooved urethane to\nassure tight joints. Provide double seal serrated neoprene\nrubber gaskets to assure air and vapor tight joints on the\ninterior and exterior of each panel along every tongue.\nInsulation\n127 mm (5 inch) and 101 mm (4 inch) minimum foamed in-\nplace polyurethane per detail drawings with manufacturer s\nrated K factor of not more than 0.15, free rise design of\nnot less than 27 kg per cubic meter (1.7 pounds per cubic\nfoot), or in-place density of not less than 32 kg per cubic\nmeter (2 pounds per cubic foot).\n\nDoor Panel and Door\na. Provide channel thermal breaker type reinforcing steel\nframe around the entire perimeter of the door opening.\nb. Door to be an in-fitting flush-mounted type with dual\nflexible blade wiper gasket on the bottom, and a\nreplaceable magnetic gasket on the top edge and along both\nsides.\nc. Provide heated, double glass view windows in refrigerator\ndoors.\nd. Door to be equipped with a minimum of three (3) hinges, for\nrough usage including aluminum diamond plate on inside of\ndoor panel and frame to a height of 915 mm (36 inches).\ne. Provide hydraulic exterior door closer to prevent slamming\nand assure secure closing.\nf. Door hinges and latch and strike assembly: Manufacturer's\nstandard, self-closing cam-lift type hinges, for 1219 mm\n(48 inch) door, chrome plated or polished aluminum finish,\nmade to provide for locking, but with an inside safety\nrelease mechanism to prevent anyone from being locked\ninside when door is locked from outside.\ng. Concealed, energy use selective, anti-sweat heater wire\ncircuit: Provide sufficient heat to prevent condensation\nand frost formation at the door jambs and exterior edges of\nthe door on all sides.\nh. Thermometer: Manufacturer's standard, 50 mm (2-inch)\nminimum diameter, dial type, flush mounted in door panel.\nPressure Relief Port\nProvide for all freezers operating at\n18 degree C (0-degree F), or lower, two-way type ports, to\nallow for an increase or decrease of air pressure on the\ninterior of the freezer to equalize with air pressure on the exterior. Provide ports with automatically controlled, UL\napproved anti-sweat heaters. Complete device to carry UL Label\nand be assembled ready for connection. Install port in a wall\npanel away from the direct air stream flowing from the coils.\nFloor Panels\na. Floor Panel Strength: Capable of withstanding 47.8 kPa (\n1000 pounds per square foot) uniform load.\nb. Provide prefabricated floor panels of the same construction\nas wall/ceiling .100 aluminum diamond treadplate surface\nover 13 mm (.5 inch) marine grade plywood Provide\nprefabricated floor panels which are recessed with, panels\nflush with surrounding building floor. Furnish two (2) sets\nof erection tools, compatible with fasteners, with each unit.\nc. Wherever compartment dimension exceeds clear-span ability of\nceiling panels, provide I-beam support on exterior of ceiling or\nspline-hangers. Install 13 mm (1/2 inch) diameter steel rods\nthrough beam/hangers and secure to structure above. Beams or\nposts within compartments are not acceptable.\nd. Rub rail wall protectors: Manufacturer s standard, at floor line\nof walls exposed to traffic.\nLighting\nLights: Provide high-efficiency rated LED light fixtures with\nsafety shields. Lighting must conform with UL IP-65. Provide with\ndiffuser and be capable of operating in minus 23 degrees C (-40\ndegrees Fahrenheit) temperature. Lights must run length of walkin\nstarting 610 mm (24 inches) from front panel and extending\nwithin 610 mm (24 inches) of back panel. Run between shelf rows\nto obtain 323 lux (30 foot-candles) at floor level regardless of\nany interior furnishings.\nCondensing Units\nComply with ARI Standard 520. Air cooled, type as shown in construction documents. (See Section 5 Below Drawings).\nB. Provide motor driven integral compressor, motor starter,\ncondenser, receiver, common base, and safety/operational\ncontrols.\nC. Receiver capacity not to be less than 125 percent of system\nrefrigerant charge.\nD. For units racked above each other and for units installed in a\ncloset, provide a factory fabricated steel rack extending\napproximately 1143 mm (45 inches) above the floor.\nE. Provide two (2) condensing units and unit coolers with\nindependent refrigeration systems for freezer when shown on\nconstruction documents or recommended by manufacturer due to size\nor freezer.\nF. Do not locate compressors on top of refrigerators or freezers.\nG. Provide positive oil lubrication and oil level indicating device\nfor each compressor. Provide water regulating valve for water\ncooled unit.\nH. Compressor Motor: Squirrel cage induction type of ample size for\ncontinuous operating at maximum compressor performance. Provide\ninherent protection, in compressor terminal box, for each phase\nof motor.\nI. Pressure Switches: Automatic reset low pressure switch, and\nautomatic or manual reset high pressure cutout.\nAir Cooled Condensing Units\n1. High efficiency type piped and automatically controlled to\noperate at lower head pressures during low ambient temperature\nconditions. Designed and weather-proofed for outdoor\ninstallation, to operate satisfactorily at winter ambient\ntemperatures down to 6 degrees C (10 degrees F), and be\nprovided with crankcase and receiver heaters.\n2. The condenser fans are to be driven by permanent split\ncapacitor motors.\nUnit Coolers\nA. Comply with ARI Standard 420. Units to be UL listed,\nforced-ventilation type. Provide demand defrost controllers for defrosting, internal or external refrigerant distributor, single\nor multiple fans and motors, drip-pan, deflectors, aluminum or\nbaked-enamel steel housing, hangers, and all accessories. Unit\ncoolers for kitchen walk-in units to be NSF approved.\nB. Motors: Permanent split capacitor type in accordance with\nSection 11 05 12, GENERAL MOTOR REQUIREMENTS FOR EQUIPMENT.\nProvide motors with thermal overload protection and manual\nstarting switch.\nC. Drain Pans: Galvanized sheet steel. Provide additional drain pans\nunder uncovered refrigerant connections, and interconnect them\nwith main drain pan. For freezer units provide electrically\nheated drain pan with heated tape over condensate drain line.\nDefrost Provision\n1. Refrigerators: Defrost to be as needed with Demand defrost\ncontrollers and occur during compressor off cycle with\nevaporator fan running continuously.\n2. Freezer defrost: Defrost to be by demand defrost with Evaporator Efficiency Controller.\nMonitoring Alarm System\nA. Provide an electronic monitoring and alarm system for each\nsection of each unit.\n1. System Components: Detecting thermostat, master control panel,\ninterconnecting wiring, remote audible alarm, and defrost\ncompensator. Provide dials showing temperatures and pilot\nlights, warning lights, switches, transformer, and buzzer, all\nas a part of the master control panel. Locate master control\npanel and remote audible alarm as indicated on construction\ndocuments. Provide power fuse to protect system components.\n2. System Operation: Set alarms at 5 degrees C (10 degrees F)\nabove and below specified operating temperatures.\nB. Personnel Alarm: For each unit, provide separate audible alarm\nsystem operable from inside unit, for use of personnel unable to\nexit unit. Locate remote audible alarm where indicated on\nconstruction documents.\nRefrigeration Rack System\nA. Digital Rack System. Provide two (2) rack systems for Walk-in\ncooler and freezer assembly, item 7. One rack system shall include\nfour (4) compressors, one for each of the four compartments. The\nsecond rack system shall provide duplicate compressors for the\nlarge cooler and large freezer compartments only. The second rack\nsystem shall be designed to alternate running cycles during\nnormal operation and also to allow one compressor set to continue\nto run should the other system have a compressor require service.\nB. The UL-Listed, air-cooled rack systems shall be designed for\noutdoor installation. The units shall be pre-wired for a single\npoint electrical connection with a main fused disconnect. The\nrefrigeration units shall be housed in a weather-protected\ncompact structural galvanized steel frame. The units shall\ninclude individual dedicated air-cooled condensers. Condensers\nshall be aluminum fin/copper tube designed to operate at 15\ndegrees T.D. The exterior housings shall be brushed 304 stainless\nsteel with one-piece stainless-steel lift out louver panels for\neasy access to service. Entire galvanized metal frame shall be\npre-assembled, welded and cleaned. Lifting points shall be\nintegrated in the feet at each corner to facilitate installation.\nCondenser fan motors shall be mounted within the enclosure.\nC. All Primary multiplex compressors shall be digital semi-hermetic\nor scroll type and factory assembled to operate with the\nrefrigerant specified.\nD. All Conventional, stand-by, and/or parallel compressors shall be\nsemi-hermetic or scroll type and factory assembled to operate\nwith specified refrigerant blend.\nE. Compressors and refrigeration piping will be installed in such a\nmanner as to eliminate noise with vibration eliminators in\nrefrigeration lines, as needed. Each compressor unit shall be\nequipped with; oversized receiver, dual pressure control for cut in cut-out, a ball-bearing fan motor, fixed head pressure\ncontrol, suction filter, liquid line sight glass, liquid line\ndrier, crankcase heaters, headmaster controls and/or fan cycling,\nliquid line inlet and outlet valves, defrost cycle and armored\nsuper hose connections (in lieu of capillary tubes).\nF. All refrigerant lines shall be extended to one side of the\npackage in a neat and orderly manner. All tubing shall be\nsecurely supported and anchored with non-corrosive coated clamps.\nAll joints must be brazed, not soldered. All piping and controls\nshall be factory pressure-tested with nitrogen at 175 PSI.\nG. Evaporator coils shall be a direct expansion type. Evaporators\nused will be all \"Underwriters Laboratory Listed\" supplied from\nfactory with an electric expansion valve, solenoid valve, suction\ntransducer, and Eco-Smart on-demand defrost controller, pre-wired\nand pre-piped under nitrogen pressure and designed for use with\nthe refrigerant specified. Isolation ball valves are to be\ninstalled on the liquid and suction lines at each evaporator\ncoil.\n\nWarranty\n\nManufacturer shall agree to repair or replace compressors that fail in materials or workmanship within five (5) years from the date of receipt. Failure includes but is not limited to inability to maintain set temperature. Walk-in Panels to be warranted for five (5) years.\n\nPublications\n\nThe publications listed below form a part of this specification to the extent referenced in the salient characteristics.\n\nPublication\nPublication Description\nAir-Conditioning and Refrigeration Institute (ARI) 420-08\nUnit Coolers for Refrigeration\nAir-Conditioning and Refrigeration Institute (ARI) 520-04\nPerformance Rating of Positive\nDisplacement Condensing Units\nAmerican Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 15-10-16\nSafety Standard for Refrigeration Systems\nASTM International (ASTM) A240/A240M-20\nChromium and Chromium-Nickel Stainless\nSteel Plate, Sheet, and Strip for\nPressure Vessels and For General\nApplications\nASTM International (ASTM) E84-20\nSurface Burning Characteristics of Building Materials\nNational Sanitation Foundation/American National Standard\n(NSF/ANSI)7-09\nCommercial Refrigerators and Storage Freezers\nNational Fire Protection Association (NFPA) 70-20\nNational Electric Code\nUnderwriters Laboratories, Inc. (UL) 207-08 (R2014)\nRefrigerant-Containing Components and Accessories, Nonelectrical\nUnderwriters Laboratories, Inc. (UL) 471-10 (R2014)\nCommercial Refrigerators and Freezers\nUnderwriters Laboratories, Inc. (UL) 1598-03 (R2012)\nLuninaires\n\nDrawings\n\nDelivery Location\nAttn: Beth Bova\nBOVA Corporation\n111 McFann Rd\nValencia, PA 16059\nEmail: beth@bovacorp.com\nPhone: (724) 898-0288\n\nPrior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Logistics using the email(s) listed above.\nThe Contractor must comply and provide all necessary information to VA Clarksburg and BOVA Corporation. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.\nRequested Delivery Date\nDelivery of equipment is requested to occur approximately 8-10 weeks ARO (After Receipt of Order). The typical lead time for this type of equipment is eight (8) weeks.\nSafety Data Sheet (SDS)\n\nIf applicable, contractor shall provide three (3) copies of each Safety Data Sheet for every product, chemical, etc. SDS sheets shall be provided on the same day those materials arrive at BOVA Corporation.\nDelivery Coordination\n\nNormal business hours for acceptance of deliveries are 7:30AM 12:00PM and 12:30PM 3:00PM (Eastern Time), Monday thru Friday excluding Holidays. Deliveries must be coordinated in advance with COR, Service Line Representative and Vendor POC (Beth Bova) once a ship date is established.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0588","place_of_performance":{"zip":"26301","city":{"code":"15628","name":"Clarksburg"},"state":{"code":"WV","name":"West Virginia"},"street":"Louis A Johnson VA Medical Center 1 Medical Center Drive","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4110"}],"due_at":"2025-06-27T16:00:00Z","due_date":"2025-06-27","closes_at":"2025-06-27T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-12T13:46:33.070471Z","principal_notice_id":"7f231a2a33be4db9b79a10e271bbe9b9","description":{"text":"RFI 36C24525Q0588\nWALK-IN FREEZERS-COOLERS\n\nTHIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought/RFI/RFI only. The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 333415 (1,250 Employes). Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Martinsburg Network Contracting Office, is seeking sources who can possibly provide Walk In Freezers & Coolers for the Louis A Johnson VA Medical Center, Clarksburg, WV 26301.\nIt is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.\nIf you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) Are you the manufacturer, authorized distributor, and/or can you provide equivalent solution to the items being referenced above?\n(4) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(6) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in FAR 19.505? Specifically, what percentage of the work will be performed by your company versus subcontractors?\n(7) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items\n(8) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Take ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice?\n(9) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(10) Please complete FAR 52.225-2 below.\n(11) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(12) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solution you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(13) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(14) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics or equal to items for planning purposes; show clear, compelling and convincing evidence that all equal to items\" meet all the salient characteristics.\n(15) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(16) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Phillip.Duba@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, June 27, 2025 by 12:00 PM EST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement.\nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\n\nStatement of Work\nVA Clarksburg\n\nGENERAL SPECIFICATIONS FOR WALK-IN COOLERS/FREEZERS\nBackground\nThe Louis A. Johnson VAMC is executing contract # 36C24521C0034, VA Project No. 540-370. The project includes renovation of the kitchen area of the hospital and will require the purchase of Walk-In coolers and Freezers equal to the specifications detailed below in salient characteristics.\nSpecifications\nPlease see below for salient characteristics.\nGeneral Description\nPrefabricated, sectional, all-metal clad, modular, and designed for easy accurate field assembly. Walk-In units must be for food service use conforming to NSF/ANSI 7, UL 207 and UL 471. Floor panel with appropriate insulated floor assembly and aluminum tread finish floor. See drawings in Section 5 for layout/additional details.\nPanels General\nInterchangeable, 1219 mm (48 inch) maximum width, 126\nmm (5 inch) thick exterior wall, floor and ceiling panels, and\n101 mm (4 inch) thick interior dividing wall panels between\ncompartments, filled with insulation. Double seal serrated\nneoprene rubber gaskets to assure air and vapor tight joints.\nPanels - Corner\n90-degree angle, radiuses 15 mm (0.5 inch)\ninside and outside, with 305 mm (12-inch) dimensions each\nside.\nPanels - Edges\nFoam-in-place, tongue-and-grooved urethane to\nassure tight joints. Provide double seal serrated neoprene\nrubber gaskets to assure air and vapor tight joints on the\ninterior and exterior of each panel along every tongue.\nInsulation\n127 mm (5 inch) and 101 mm (4 inch) minimum foamed in-\nplace polyurethane per detail drawings with manufacturer s\nrated K factor of not more than 0.15, free rise design of\nnot less than 27 kg per cubic meter (1.7 pounds per cubic\nfoot), or in-place density of not less than 32 kg per cubic\nmeter (2 pounds per cubic foot).\n\nDoor Panel and Door\na. Provide channel thermal breaker type reinforcing steel\nframe around the entire perimeter of the door opening.\nb. Door to be an in-fitting flush-mounted type with dual\nflexible blade wiper gasket on the bottom, and a\nreplaceable magnetic gasket on the top edge and along both\nsides.\nc. Provide heated, double glass view windows in refrigerator\ndoors.\nd. Door to be equipped with a minimum of three (3) hinges, for\nrough usage including aluminum diamond plate on inside of\ndoor panel and frame to a height of 915 mm (36 inches).\ne. Provide hydraulic exterior door closer to prevent slamming\nand assure secure closing.\nf. Door hinges and latch and strike assembly: Manufacturer's\nstandard, self-closing cam-lift type hinges, for 1219 mm\n(48 inch) door, chrome plated or polished aluminum finish,\nmade to provide for locking, but with an inside safety\nrelease mechanism to prevent anyone from being locked\ninside when door is locked from outside.\ng. Concealed, energy use selective, anti-sweat heater wire\ncircuit: Provide sufficient heat to prevent condensation\nand frost formation at the door jambs and exterior edges of\nthe door on all sides.\nh. Thermometer: Manufacturer's standard, 50 mm (2-inch)\nminimum diameter, dial type, flush mounted in door panel.\nPressure Relief Port\nProvide for all freezers operating at\n18 degree C (0-degree F), or lower, two-way type ports, to\nallow for an increase or decrease of air pressure on the\ninterior of the freezer to equalize with air pressure on the exterior. Provide ports with automatically controlled, UL\napproved anti-sweat heaters. Complete device to carry UL Label\nand be assembled ready for connection. Install port in a wall\npanel away from the direct air stream flowing from the coils.\nFloor Panels\na. Floor Panel Strength: Capable of withstanding 47.8 kPa (\n1000 pounds per square foot) uniform load.\nb. Provide prefabricated floor panels of the same construction\nas wall/ceiling .100 aluminum diamond treadplate surface\nover 13 mm (.5 inch) marine grade plywood Provide\nprefabricated floor panels which are recessed with, panels\nflush with surrounding building floor. Furnish two (2) sets\nof erection tools, compatible with fasteners, with each unit.\nc. Wherever compartment dimension exceeds clear-span ability of\nceiling panels, provide I-beam support on exterior of ceiling or\nspline-hangers. Install 13 mm (1/2 inch) diameter steel rods\nthrough beam/hangers and secure to structure above. Beams or\nposts within compartments are not acceptable.\nd. Rub rail wall protectors: Manufacturer s standard, at floor line\nof walls exposed to traffic.\nLighting\nLights: Provide high-efficiency rated LED light fixtures with\nsafety shields. Lighting must conform with UL IP-65. Provide with\ndiffuser and be capable of operating in minus 23 degrees C (-40\ndegrees Fahrenheit) temperature. Lights must run length of walkin\nstarting 610 mm (24 inches) from front panel and extending\nwithin 610 mm (24 inches) of back panel. Run between shelf rows\nto obtain 323 lux (30 foot-candles) at floor level regardless of\nany interior furnishings.\nCondensing Units\nComply with ARI Standard 520. Air cooled, type as shown in construction documents. (See Section 5 Below Drawings).\nB. Provide motor driven integral compressor, motor starter,\ncondenser, receiver, common base, and safety/operational\ncontrols.\nC. Receiver capacity not to be less than 125 percent of system\nrefrigerant charge.\nD. For units racked above each other and for units installed in a\ncloset, provide a factory fabricated steel rack extending\napproximately 1143 mm (45 inches) above the floor.\nE. Provide two (2) condensing units and unit coolers with\nindependent refrigeration systems for freezer when shown on\nconstruction documents or recommended by manufacturer due to size\nor freezer.\nF. Do not locate compressors on top of refrigerators or freezers.\nG. Provide positive oil lubrication and oil level indicating device\nfor each compressor. Provide water regulating valve for water\ncooled unit.\nH. Compressor Motor: Squirrel cage induction type of ample size for\ncontinuous operating at maximum compressor performance. Provide\ninherent protection, in compressor terminal box, for each phase\nof motor.\nI. Pressure Switches: Automatic reset low pressure switch, and\nautomatic or manual reset high pressure cutout.\nAir Cooled Condensing Units\n1. High efficiency type piped and automatically controlled to\noperate at lower head pressures during low ambient temperature\nconditions. Designed and weather-proofed for outdoor\ninstallation, to operate satisfactorily at winter ambient\ntemperatures down to 6 degrees C (10 degrees F), and be\nprovided with crankcase and receiver heaters.\n2. The condenser fans are to be driven by permanent split\ncapacitor motors.\nUnit Coolers\nA. Comply with ARI Standard 420. Units to be UL listed,\nforced-ventilation type. Provide demand defrost controllers for defrosting, internal or external refrigerant distributor, single\nor multiple fans and motors, drip-pan, deflectors, aluminum or\nbaked-enamel steel housing, hangers, and all accessories. Unit\ncoolers for kitchen walk-in units to be NSF approved.\nB. Motors: Permanent split capacitor type in accordance with\nSection 11 05 12, GENERAL MOTOR REQUIREMENTS FOR EQUIPMENT.\nProvide motors with thermal overload protection and manual\nstarting switch.\nC. Drain Pans: Galvanized sheet steel. Provide additional drain pans\nunder uncovered refrigerant connections, and interconnect them\nwith main drain pan. For freezer units provide electrically\nheated drain pan with heated tape over condensate drain line.\nDefrost Provision\n1. Refrigerators: Defrost to be as needed with Demand defrost\ncontrollers and occur during compressor off cycle with\nevaporator fan running continuously.\n2. Freezer defrost: Defrost to be by demand defrost with Evaporator Efficiency Controller.\nMonitoring Alarm System\nA. Provide an electronic monitoring and alarm system for each\nsection of each unit.\n1. System Components: Detecting thermostat, master control panel,\ninterconnecting wiring, remote audible alarm, and defrost\ncompensator. Provide dials showing temperatures and pilot\nlights, warning lights, switches, transformer, and buzzer, all\nas a part of the master control panel. Locate master control\npanel and remote audible alarm as indicated on construction\ndocuments. Provide power fuse to protect system components.\n2. System Operation: Set alarms at 5 degrees C (10 degrees F)\nabove and below specified operating temperatures.\nB. Personnel Alarm: For each unit, provide separate audible alarm\nsystem operable from inside unit, for use of personnel unable to\nexit unit. Locate remote audible alarm where indicated on\nconstruction documents.\nRefrigeration Rack System\nA. Digital Rack System. Provide two (2) rack systems for Walk-in\ncooler and freezer assembly, item 7. One rack system shall include\nfour (4) compressors, one for each of the four compartments. The\nsecond rack system shall provide duplicate compressors for the\nlarge cooler and large freezer compartments only. The second rack\nsystem shall be designed to alternate running cycles during\nnormal operation and also to allow one compressor set to continue\nto run should the other system have a compressor require service.\nB. The UL-Listed, air-cooled rack systems shall be designed for\noutdoor installation. The units shall be pre-wired for a single\npoint electrical connection with a main fused disconnect. The\nrefrigeration units shall be housed in a weather-protected\ncompact structural galvanized steel frame. The units shall\ninclude individual dedicated air-cooled condensers. Condensers\nshall be aluminum fin/copper tube designed to operate at 15\ndegrees T.D. The exterior housings shall be brushed 304 stainless\nsteel with one-piece stainless-steel lift out louver panels for\neasy access to service. Entire galvanized metal frame shall be\npre-assembled, welded and cleaned. Lifting points shall be\nintegrated in the feet at each corner to facilitate installation.\nCondenser fan motors shall be mounted within the enclosure.\nC. All Primary multiplex compressors shall be digital semi-hermetic\nor scroll type and factory assembled to operate with the\nrefrigerant specified.\nD. All Conventional, stand-by, and/or parallel compressors shall be\nsemi-hermetic or scroll type and factory assembled to operate\nwith specified refrigerant blend.\nE. Compressors and refrigeration piping will be installed in such a\nmanner as to eliminate noise with vibration eliminators in\nrefrigeration lines, as needed. Each compressor unit shall be\nequipped with; oversized receiver, dual pressure control for cut in cut-out, a ball-bearing fan motor, fixed head pressure\ncontrol, suction filter, liquid line sight glass, liquid line\ndrier, crankcase heaters, headmaster controls and/or fan cycling,\nliquid line inlet and outlet valves, defrost cycle and armored\nsuper hose connections (in lieu of capillary tubes).\nF. All refrigerant lines shall be extended to one side of the\npackage in a neat and orderly manner. All tubing shall be\nsecurely supported and anchored with non-corrosive coated clamps.\nAll joints must be brazed, not soldered. All piping and controls\nshall be factory pressure-tested with nitrogen at 175 PSI.\nG. Evaporator coils shall be a direct expansion type. Evaporators\nused will be all \"Underwriters Laboratory Listed\" supplied from\nfactory with an electric expansion valve, solenoid valve, suction\ntransducer, and Eco-Smart on-demand defrost controller, pre-wired\nand pre-piped under nitrogen pressure and designed for use with\nthe refrigerant specified. Isolation ball valves are to be\ninstalled on the liquid and suction lines at each evaporator\ncoil.\n\nWarranty\n\nManufacturer shall agree to repair or replace compressors that fail in materials or workmanship within five (5) years from the date of receipt. Failure includes but is not limited to inability to maintain set temperature. Walk-in Panels to be warranted for five (5) years.\n\nPublications\n\nThe publications listed below form a part of this specification to the extent referenced in the salient characteristics.\n\nPublication\nPublication Description\nAir-Conditioning and Refrigeration Institute (ARI) 420-08\nUnit Coolers for Refrigeration\nAir-Conditioning and Refrigeration Institute (ARI) 520-04\nPerformance Rating of Positive\nDisplacement Condensing Units\nAmerican Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 15-10-16\nSafety Standard for Refrigeration Systems\nASTM International (ASTM) A240/A240M-20\nChromium and Chromium-Nickel Stainless\nSteel Plate, Sheet, and Strip for\nPressure Vessels and For General\nApplications\nASTM International (ASTM) E84-20\nSurface Burning Characteristics of Building Materials\nNational Sanitation Foundation/American National Standard\n(NSF/ANSI)7-09\nCommercial Refrigerators and Storage Freezers\nNational Fire Protection Association (NFPA) 70-20\nNational Electric Code\nUnderwriters Laboratories, Inc. (UL) 207-08 (R2014)\nRefrigerant-Containing Components and Accessories, Nonelectrical\nUnderwriters Laboratories, Inc. (UL) 471-10 (R2014)\nCommercial Refrigerators and Freezers\nUnderwriters Laboratories, Inc. (UL) 1598-03 (R2012)\nLuninaires\n\nDrawings\n\nDelivery Location\nAttn: Beth Bova\nBOVA Corporation\n111 McFann Rd\nValencia, PA 16059\nEmail: beth@bovacorp.com\nPhone: (724) 898-0288\n\nPrior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Logistics using the email(s) listed above.\nThe Contractor must comply and provide all necessary information to VA Clarksburg and BOVA Corporation. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.\nRequested Delivery Date\nDelivery of equipment is requested to occur approximately 8-10 weeks ARO (After Receipt of Order). The typical lead time for this type of equipment is eight (8) weeks.\nSafety Data Sheet (SDS)\n\nIf applicable, contractor shall provide three (3) copies of each Safety Data Sheet for every product, chemical, etc. SDS sheets shall be provided on the same day those materials arrive at BOVA Corporation.\nDelivery Coordination\n\nNormal business hours for acceptance of deliveries are 7:30AM 12:00PM and 12:30PM 3:00PM (Eastern Time), Monday thru Friday excluding Holidays. Deliveries must be coordinated in advance with COR, Service Line Representative and Vendor POC (Beth Bova) once a ship date is established.","html":"RFI 36C24525Q0588\nWALK-IN FREEZERS-COOLERS\n\nTHIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought/RFI/RFI only.  The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 333415 (1,250 Employes). Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought/RFI, a solicitation announcement may be published.  Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.  \nThe Department of Veterans Affairs (VA), VISN 5 Martinsburg Network Contracting Office, is seeking sources who can possibly provide Walk In Freezers & Coolers for the Louis A Johnson VA Medical Center, Clarksburg, WV  26301.\nIt is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. \nIf you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) Are you the manufacturer, authorized distributor, and/or can you provide equivalent solution to the items being referenced above?\n(4) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(6) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in FAR 19.505? Specifically, what percentage of the work will be performed by your company versus subcontractors?\n(7) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items\n(8) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Take ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice?\n(9) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(10) Please complete FAR 52.225-2 below.\n(11) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(12) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solution you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(13) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(14) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics or  equal to items  for planning purposes; show clear, compelling and convincing evidence that all  equal to items\" meet all the salient characteristics.\n(15) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(16) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Phillip.Duba@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Friday, June 27, 2025 by 12:00 PM EST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement. \nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\n\nStatement of Work\nVA Clarksburg\n\nGENERAL SPECIFICATIONS FOR WALK-IN COOLERS/FREEZERS \nBackground\nThe Louis A. Johnson VAMC is executing contract # 36C24521C0034, VA Project No. 540-370. The project includes renovation of the kitchen area of the hospital and will require the purchase of Walk-In coolers and Freezers equal to the specifications detailed below in salient characteristics.\nSpecifications\nPlease see below for salient characteristics.  \nGeneral Description\nPrefabricated, sectional, all-metal clad, modular, and designed for easy accurate field assembly.  Walk-In units must be for food service use conforming to NSF/ANSI 7, UL 207 and UL 471.  Floor panel with appropriate insulated floor assembly and aluminum tread finish floor.  See drawings in Section 5 for layout/additional details.\nPanels   General\nInterchangeable, 1219 mm (48 inch) maximum width, 126\nmm (5 inch) thick exterior wall, floor and ceiling panels, and\n101 mm (4 inch) thick interior dividing wall panels between\ncompartments, filled with insulation. Double seal serrated\nneoprene rubber gaskets to assure air and vapor tight joints.\nPanels - Corner\n90-degree angle, radiuses 15 mm (0.5 inch)\ninside and outside, with 305 mm (12-inch) dimensions each\nside.\nPanels - Edges\nFoam-in-place, tongue-and-grooved urethane to\nassure tight joints. Provide double seal serrated neoprene\nrubber gaskets to assure air and vapor tight joints on the\ninterior and exterior of each panel along every tongue.\nInsulation\n127 mm (5 inch) and 101 mm (4 inch) minimum foamed in-\nplace polyurethane per detail drawings with manufacturer s\nrated  K  factor of not more than 0.15, free rise design of\nnot less than 27 kg per cubic meter (1.7 pounds per cubic\nfoot), or in-place density of not less than 32 kg per cubic\nmeter (2 pounds per cubic foot).\n\nDoor Panel and Door\na. Provide channel thermal breaker type reinforcing steel\nframe around the entire perimeter of the door opening.\nb. Door to be an in-fitting flush-mounted type with dual\nflexible blade wiper gasket on the bottom, and a\nreplaceable magnetic gasket on the top edge and along both\nsides.\nc. Provide heated, double glass view windows in refrigerator\ndoors.\nd. Door to be equipped with a minimum of three (3) hinges, for\nrough usage including aluminum diamond plate on inside of\ndoor panel and frame to a height of 915 mm (36 inches).\ne. Provide hydraulic exterior door closer to prevent slamming\nand assure secure closing.\nf. Door hinges and latch and strike assembly: Manufacturer's\nstandard, self-closing cam-lift type hinges, for 1219 mm\n(48 inch) door, chrome plated or polished aluminum finish,\nmade to provide for locking, but with an inside safety\nrelease mechanism to prevent anyone from being locked\ninside when door is locked from outside.\ng. Concealed, energy use selective, anti-sweat heater wire\ncircuit: Provide sufficient heat to prevent condensation\nand frost formation at the door jambs and exterior edges of\nthe door on all sides.\nh. Thermometer: Manufacturer's standard, 50 mm (2-inch)\nminimum diameter, dial type, flush mounted in door panel.\nPressure Relief Port\nProvide for all freezers operating at\n18 degree C (0-degree F), or lower, two-way type ports, to\nallow for an increase or decrease of air pressure on the\ninterior of the freezer to equalize with air pressure on the exterior. Provide ports with automatically controlled, UL\napproved anti-sweat heaters. Complete device to carry UL Label\nand be assembled ready for connection. Install port in a wall\npanel away from the direct air stream flowing from the coils.\nFloor Panels\na. Floor Panel Strength: Capable of withstanding 47.8 kPa (\n1000 pounds per square foot) uniform load.\nb. Provide prefabricated floor panels of the same construction\nas wall/ceiling .100 aluminum diamond treadplate surface\nover 13 mm (.5 inch) marine grade plywood Provide\nprefabricated floor panels which are recessed with, panels\nflush with surrounding building floor. Furnish two (2) sets\nof erection tools, compatible with fasteners, with each unit.\nc. Wherever compartment dimension exceeds clear-span ability of\nceiling panels, provide I-beam support on exterior of ceiling or\nspline-hangers. Install 13 mm (1/2 inch) diameter steel rods\nthrough beam/hangers and secure to structure above. Beams or\nposts within compartments are not acceptable.\nd. Rub rail wall protectors: Manufacturer s standard, at floor line\nof walls exposed to traffic.\nLighting\nLights: Provide high-efficiency rated LED light fixtures with\nsafety shields. Lighting must conform with UL IP-65. Provide with\ndiffuser and be capable of operating in minus 23 degrees C (-40\ndegrees Fahrenheit) temperature. Lights must run length of walkin\nstarting 610 mm (24 inches) from front panel and extending\nwithin 610 mm (24 inches) of back panel. Run between shelf rows\nto obtain 323 lux (30 foot-candles) at floor level regardless of\nany interior furnishings.\nCondensing Units\n Comply with ARI Standard 520. Air cooled, type as shown in construction documents. (See Section 5 Below   Drawings).\nB. Provide motor driven integral compressor, motor starter,\ncondenser, receiver, common base, and safety/operational\ncontrols.\nC. Receiver capacity not to be less than 125 percent of system\nrefrigerant charge.\nD. For units racked above each other and for units installed in a\ncloset, provide a factory fabricated steel rack extending\napproximately 1143 mm (45 inches) above the floor.\nE. Provide two (2) condensing units and unit coolers with\nindependent refrigeration systems for freezer when shown on\nconstruction documents or recommended by manufacturer due to size\nor freezer.\nF. Do not locate compressors on top of refrigerators or freezers.\nG. Provide positive oil lubrication and oil level indicating device\nfor each compressor. Provide water regulating valve for water\ncooled unit.\nH. Compressor Motor: Squirrel cage induction type of ample size for\ncontinuous operating at maximum compressor performance. Provide\ninherent protection, in compressor terminal box, for each phase\nof motor.\nI. Pressure Switches: Automatic reset low pressure switch, and\nautomatic or manual reset high pressure cutout.\nAir Cooled Condensing Units\n1. High efficiency type piped and automatically controlled to\noperate at lower head pressures during low ambient temperature\nconditions. Designed and weather-proofed for outdoor\ninstallation, to operate satisfactorily at winter ambient\ntemperatures down to 6 degrees C (10 degrees F), and be\nprovided with crankcase and receiver heaters.\n2. The condenser fans are to be driven by permanent split\ncapacitor motors.\nUnit Coolers\nA. Comply with ARI Standard 420. Units to be UL listed,\nforced-ventilation type. Provide demand defrost controllers for defrosting, internal or external refrigerant distributor, single\nor multiple fans and motors, drip-pan, deflectors, aluminum or\nbaked-enamel steel housing, hangers, and all accessories. Unit\ncoolers for kitchen walk-in units to be NSF approved.\nB. Motors: Permanent split capacitor type in accordance with\nSection 11 05 12, GENERAL MOTOR REQUIREMENTS FOR EQUIPMENT.\nProvide motors with thermal overload protection and manual\nstarting switch.\nC. Drain Pans: Galvanized sheet steel. Provide additional drain pans\nunder uncovered refrigerant connections, and interconnect them\nwith main drain pan. For freezer units provide electrically\nheated drain pan with heated tape over condensate drain line.\nDefrost Provision\n1. Refrigerators: Defrost to be as needed with Demand defrost\ncontrollers and occur during compressor off cycle with\nevaporator fan running continuously.\n2. Freezer defrost: Defrost to be by demand defrost with Evaporator Efficiency Controller.\nMonitoring Alarm System\nA. Provide an electronic monitoring and alarm system for each\nsection of each unit.\n1. System Components: Detecting thermostat, master control panel,\ninterconnecting wiring, remote audible alarm, and defrost\ncompensator. Provide dials showing temperatures and pilot\nlights, warning lights, switches, transformer, and buzzer, all\nas a part of the master control panel. Locate master control\npanel and remote audible alarm as indicated on construction\ndocuments. Provide power fuse to protect system components.\n2. System Operation: Set alarms at 5 degrees C (10 degrees F)\nabove and below specified operating temperatures.\nB. Personnel Alarm: For each unit, provide separate audible alarm\nsystem operable from inside unit, for use of personnel unable to\nexit unit. Locate remote audible alarm where indicated on\nconstruction documents.\nRefrigeration Rack System\nA. Digital Rack System. Provide two (2) rack systems for Walk-in\ncooler and freezer assembly, item 7. One rack system shall include\nfour (4) compressors, one for each of the four compartments. The\nsecond rack system shall provide duplicate compressors for the\nlarge cooler and large freezer compartments only. The second rack\nsystem shall be designed to alternate running cycles during\nnormal operation and also to allow one compressor set to continue\nto run should the other system have a compressor require service.\nB. The UL-Listed, air-cooled rack systems shall be designed for\noutdoor installation. The units shall be pre-wired for a single\npoint electrical connection with a main fused disconnect. The\nrefrigeration units shall be housed in a weather-protected\ncompact structural galvanized steel frame. The units shall\ninclude individual dedicated air-cooled condensers. Condensers\nshall be aluminum fin/copper tube designed to operate at 15\ndegrees T.D. The exterior housings shall be brushed 304 stainless\nsteel with one-piece stainless-steel lift out louver panels for\neasy access to service. Entire galvanized metal frame shall be\npre-assembled, welded and cleaned. Lifting points shall be\nintegrated in the feet at each corner to facilitate installation.\nCondenser fan motors shall be mounted within the enclosure.\nC. All Primary multiplex compressors shall be digital semi-hermetic\nor scroll type and factory assembled to operate with the\nrefrigerant specified.\nD. All Conventional, stand-by, and/or parallel compressors shall be\nsemi-hermetic or scroll type and factory assembled to operate\nwith specified refrigerant blend.\nE. Compressors and refrigeration piping will be installed in such a\nmanner as to eliminate noise with vibration eliminators in\nrefrigeration lines, as needed. Each compressor unit shall be\nequipped with; oversized receiver, dual pressure control for cut in cut-out, a ball-bearing fan motor, fixed head pressure\ncontrol, suction filter, liquid line sight glass, liquid line\ndrier, crankcase heaters, headmaster controls and/or fan cycling,\nliquid line inlet and outlet valves, defrost cycle and armored\nsuper hose connections (in lieu of capillary tubes).\nF. All refrigerant lines shall be extended to one side of the\npackage in a neat and orderly manner. All tubing shall be\nsecurely supported and anchored with non-corrosive coated clamps.\nAll joints must be brazed, not soldered. All piping and controls\nshall be factory pressure-tested with nitrogen at 175 PSI.\nG. Evaporator coils shall be a direct expansion type. Evaporators\nused will be all \"Underwriters Laboratory Listed\" supplied from\nfactory with an electric expansion valve, solenoid valve, suction\ntransducer, and Eco-Smart on-demand defrost controller, pre-wired\nand pre-piped under nitrogen pressure and designed for use with\nthe refrigerant specified. Isolation ball valves are to be\ninstalled on the liquid and suction lines at each evaporator\ncoil.\n\nWarranty\n\nManufacturer shall agree to repair or replace compressors that fail in materials or workmanship within five (5) years from the date of receipt. Failure includes but is not limited to inability to maintain set temperature.  Walk-in Panels to be warranted for five (5) years.\n\n\n\nPublications\n\nThe publications listed below form a part of this specification to the extent referenced in the salient characteristics.\n\nPublication\nPublication Description\nAir-Conditioning and Refrigeration Institute (ARI) 420-08\nUnit Coolers for Refrigeration\nAir-Conditioning and Refrigeration Institute (ARI) 520-04\nPerformance Rating of Positive\nDisplacement Condensing Units\nAmerican Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 15-10-16\nSafety Standard for Refrigeration Systems\nASTM International (ASTM) A240/A240M-20\nChromium and Chromium-Nickel Stainless\nSteel Plate, Sheet, and Strip for\nPressure Vessels and For General\nApplications\nASTM International (ASTM) E84-20\nSurface Burning Characteristics of Building Materials\nNational Sanitation Foundation/American National Standard\n(NSF/ANSI)7-09\nCommercial Refrigerators and Storage Freezers\nNational Fire Protection Association (NFPA) 70-20\nNational Electric Code\nUnderwriters Laboratories, Inc. (UL) 207-08 (R2014)\nRefrigerant-Containing Components and Accessories, Nonelectrical\nUnderwriters Laboratories, Inc. (UL) 471-10 (R2014)\nCommercial Refrigerators and Freezers\nUnderwriters Laboratories, Inc. (UL) 1598-03 (R2012)\nLuninaires\n\nDrawings\n\n\n\n\nDelivery Location \nAttn: Beth Bova\nBOVA Corporation\n111 McFann Rd\nValencia, PA 16059\nEmail: beth@bovacorp.com \nPhone: (724) 898-0288\n\nPrior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Logistics using the email(s) listed above.\nThe Contractor must comply and provide all necessary information to VA Clarksburg and BOVA Corporation. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. \nRequested Delivery Date\nDelivery of equipment is requested to occur approximately 8-10 weeks ARO (After Receipt of Order).  The typical lead time for this type of equipment is eight (8) weeks.\nSafety Data Sheet (SDS) \n\nIf applicable, contractor shall provide three (3) copies of each Safety Data Sheet for every product, chemical, etc.  SDS sheets shall be provided on the same day those materials arrive at BOVA Corporation.  \nDelivery Coordination\n\nNormal business hours for acceptance of deliveries are 7:30AM   12:00PM and 12:30PM   3:00PM (Eastern Time), Monday thru Friday excluding Holidays.  Deliveries must be coordinated in advance with COR, Service Line Representative and Vendor POC (Beth Bova) once a ship date is established.","origin":"detail"},"contacts":[{"name":"Phillip G Duba","role":"primary","email":"Phillip.Duba@va.gov","phone":"EMAIL ONLY - NO TELEPHONE CALL","title":"Contract Specialist"}],"place_of_performance":{"zip":"26301","city":{"code":"15628","name":"Clarksburg"},"state":{"code":"WV","name":"West Virginia"},"street":"Louis A Johnson VA Medical Center 1 Medical Center Drive","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["333415"],"award":{"awardee":{}},"attachments":[{"resource_id":"4c17602bbbb44094bbaed7bbf53e085b","name":"36C24525Q0588.docx","kind":"file","mime_type":".docx","size_bytes":4602626,"posted_at":"2025-06-16T18:50:18.129Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4c17602bbbb44094bbaed7bbf53e085b/download","mirrored":false},{"resource_id":"ca97ccfe430142508d92e9af10e455f2","name":"Louis A Johnson VAMC","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-16T18:50:18.129Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/clarksburg-health-care/locations/louis-a-","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"N0010427QXA17","latest_notice_id":"14425aee1f624e35b816a7d429c24eeb","title":"UNIT, ENVIRONMENTAL","solicitation_number":"N0010427QXA17","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333415","psc":"4120","set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"SPE7LX27U0819","latest_notice_id":"90e22b42bdb34908aff4bc44b7965633","title":"29--SEAL,FAN,SHROUD","solicitation_number":"SPE7LX27U0819","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7LX","office_name":"DLA WEAPONS SUPPORT","naics":"333415","psc":"29","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 39. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"SPE7M227U0052","latest_notice_id":"64b0c78b950c4a6696b52f446cc20149","title":"45--HEATING ELEMENT,ELECTR","solicitation_number":"SPE7M227U0052","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M2","office_name":"DLA WEAPONS SUPPORT","naics":"333415","psc":"45","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TITY WILL BE 41. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":22,"indexable":false}