# SOURCES SOUGHT NOTICE - DE-GAS THREE TRANSFORMERS - FOR Hershel Woody Williams VAMC - 581-25-4-507-0185

Canonical: https://sealedbidder.com/opportunities/36c24525q0577

- Solicitation number: 36C24525Q0577
- Notice type: Sources sought
- Status: Awarded to Power Substation Services LLC
- Department: Department of Veterans Affairs
- Contracting office: 245-Network Contract Office 5 (36C245)
- NAICS: 238210 Electrical Contractors and Other Wiring Installation Contractors
- Product or service code: J059 Maintenance, Repair and Rebuilding of Equipment: Electrical and Electronic Equipment Components
- Small business size standard: $19 million in average annual receipts (13 CFR 121.201, NAICS 238210)
- Place of performance: Huntington, West Virginia
- County: Wayne County (FIPS 54099). https://sealedbidder.com/counties/wayne-county-wv-54099
- City: Huntington. https://sealedbidder.com/cities/huntington-wv-5439460
- First posted: June 11, 2025
- Last posted: June 11, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/b0a44f11b0a4481ea5b738b20b57db12/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238210 (electrical contractors and other wiring installation contractors), means no more than $19 million in average annual receipts, counted with affiliates.
- How it ended: Awarded to Power Substation Services LLC on July 16, 2025, 20 days after offers were due. The contracting office reported 2 offers (competed under simplified acquisition procedures).

## Description

Page 1 of 3

SUMMARY:

Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor that can degas 3 transformers located at the Hershel  Woody  Williams VAMC.

STATEMENT OF WORK

A.1 INTRODUCTION   The Hershel  Woody  Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 needs to degas 3 transformers.

A.2 BACKGROUND     The main campus transformers (3) are malfunctioning most likely due to age. The three transformers require more frequent testing to ensure they do not have a catastrophic failure.
A.3  SCOPE OF WORK   Vendor will provide all labor, material, equipment, tools, and supervision necessary to meet the Statement of Work below.
  STATEMENT OF WORK PART B   WORK REQUIREMENTS

B.1  Tasks to be accomplished:

Provide on-site dielectric fluid processing and reclamation of three (3) transformer(s)

TRANSFORMER SUMMARY:
Serial Number
Location
Gallons of Fluid
Fluid Type
Primary Voltage
Energized Processing
53486
VA Hospital
736
MODF
34.4 kV
N
880988A1
VA Hospital
910
MODF
34.4 kV
N
PKF0478
VA Hospital
540
MODF
34.4 kV
N

Mobilize a field service crew and equipment to the job site.
Set up the vacuum processing rig and other equipment needed for the project.
Ensure proper grounding on all equipment involved in the project.
Perform ten (10) circulations of the fluid in each of the transformers through the vacuum-processing rig. This will remove the dissolved gases from the oil.
If any transformer needs to be topped off, there will be an additional charge for the dielectric fluid that is used to ensure the transformer is at the proper operating level. This will need to be discussed/approved by the Program POC prior to completion and PO number will be provided to the contractor outside of this contract for fluid charge prior to topping off fluids.
Sample the dielectric fluid in the transformer and have it tested for dielectric strength (D-877), interfacial tension, neutralization number, color number, moisture content in the oil and a dissolved gas analysis.
Clean the work area by removing any debris that was generated by PSS during the project.
The crew and equipment will depart from the job site.
Vendor will provide services within 14 days upon contract award.

STATEMENT OF WORK PART C   SUPPORTING INFORMATION

C.1 Place of Performance   Hershel  Woody  Williams VAMC located at 1540 Spring Valley Drive, Huntington, WV 25704. Delivery vehicles shall keep traffic disruptions to a minimum.  Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.

C.2 Period of Performance   Vendor will provide services within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM   430PM . The Contractor shall perform all services during normal business hours.

C.3 Special Considerations

C.3.1 Contractor Furnished Materials   All labor, materials, equipment to perform the   job.  When  furnish ,  provide ,  install , or similar term is used it shall mean a complete installation, ready for use.  The vendor shall supply all parts, equipment, material, and labor to perform the work described above.  The work will include all items as described in the Scope of Work listed above.
C.3.2 Government Furnished Materials and Services.  Government furnished property, if any, will be identified and will only be used for the performance of this contract unless otherwise authorized by the Contracting Officer.  The Contractor shall, at all times, take any and all steps necessary for maintenance and preservation of all Government-furnished property.  The Contractor shall comply with all reasonable requests of the Contracting Officer to enclose, or specifically protect, Government-furnished property.
C.3.3 Qualifications of Key Personnel   Contractor s employees should be knowledgeable of standards associated with this type of work.
C.3.4 Supervision/Communications.  At all times during the performance, the Contractor s Superintendent (if applicable) shall be available by cellular phone.  Prior to beginning any work, the Contractor shall supply the COR with the telephone number for the Superintendent.  The Contractor s  Competent Person  that meets OSHA training guidelines, is capable of making decisions and acting on behalf of the Contractor shall be physically located on site at all times during performance of the contract.  If the Contractor s Competent Person is absent from the job site for an extended period of time, the COR may send all Contractor/sub-contractor employees off the job.
C.3.5 Parking/Traffic Regulations.  The Contractor shall not park on grassy areas unless approved by the COR and the Contractor agrees to restore areas back to VA standards.  Drivers should be particularly concerned with pedestrian traffic.  Yield to pedestrians in crosswalks.  Posted speed limits and all other traffic controls are to be observed by operators at all times.  Seat belt use is mandatory on the VA grounds.
C.3.6 Security. The C&A requirements do not apply, and a Security Accreditation
Package is not required. This acquisition does not involve storage, generating, transmitting, or exchanging of VA sensitive information. It does not require C&A a MOU-ISA for system interconnection. Contractor shall identify which employees will be working under the awarded contract. Contractor personnel shall include employees, sub-contractors, subcontractor employees, suppliers and delivery personnel entering the Medical Center. Those employees shall bring photo ID to obtain a VA Contractor identification badge that shall be worn above the belt at all times while on Medical Center property.  Contractor s employees shall return all I.D. badges to designated personnel at time designated in the task order. This does not apply to suppliers and delivery personnel making deliveries to the VA warehouse dock only.
C.3.7 Smoking Policy.  The Contractor shall not allow smoking in any building.  The VA is a smoke-free facility. This includes the use of electronic cigarettes and vaping devices.

 Interested & Capable Responses: Must respond with the following information.

NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Huntington VA Medical Center.
Please respond to this RFI/Sources Sought Notice 36C24525Q0577 with your:

Business name (including Unique Entity ID (SAM.gov)
Business type, socio-economic status (e.g., Veteran-Owned, Woman- Owned, Disadvantaged Small Business, 8(a), etc.), and
Person of contact (including telephone number & email address).
Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities.
Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS)
Brief Summary of categories of services that your company can/cannot provide.
Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable)
Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:
Do you intend to self-perform this effort?
If you are located outside the immediate area, how will you self-perform?
Or do you intend to subcontract work under this contract?
If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?

Response Instructions:

Responses must be submitted by 10:00 AM (ET) June 26, 2025. Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. Respond: 36C24525Q0577   Sources Sought Notice | Company Name

This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred as a result of a vendor s attendance to the Site-Visit nor the preparation of responses submitted as a result of this notice.

Bill Pratt
Contract Specialist
VHA, NCO 5

## Attachments

- [36C24525Q0577.docx](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d5cda44735664ecaa184e152b65339c8/download)
- [VA](https://www.va.gov) (link)

## Award on USAspending

- Recipient: Power Substation Services LLC (UEI RH5DVD6JCJL5)
- Contract: 36C24525P0659, purchase order
- Obligated: $24,238.00
- Competition: Competed Under SAP, 2 offers received
- Link: solicitation number 36C24525Q0577 equals the FPDS solicitation identifier; same awarding office 36C245 (high confidence)
- Record: https://www.usaspending.gov/award/CONT_AWD_36C24525P0659_3600_-NONE-_-NONE-/


## Open now in the same industry

40 open in NAICS 238210.

- 541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland (36C25027Q0014), due November 27, 2026 at 3:00 PM EST. https://sealedbidder.com/opportunities/36c25027q0014
- Forest Service - Solar Batteries Frenchman Work Center (127EAW27Q0002), due November 27, 2026 at 7:00 PM EST. https://sealedbidder.com/opportunities/127eaw27q0002
- Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA) (FA706027R0001), due November 30, 2026 at 10:00 AM EST. https://sealedbidder.com/opportunities/fa706027r0001

## Publications

- June 11, 2025: Sources sought, due June 26, 2025 at 10:00 AM EDT. Notice b0a44f11b0a4481ea5b738b20b57db12. https://sam.gov/workspace/contract/opp/b0a44f11b0a4481ea5b738b20b57db12/view

## Points of contact

- Bill Pratt, Contracting Officer, Billie.Pratt@va.gov, 410-642-2411 ext. 22230

---
Source: SAM.gov Contract Opportunities bulk extract and USAspending.gov award data. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/36c24525q0577.