{"canonical":"https://sealedbidder.com/opportunities/36c24525q0522","key":"36C24525Q0522","url":"https://sealedbidder.com/opportunities/36c24525q0522","title":"6515--LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC. \"BRAND NAME OR EQUAL TO STRYKER IAW SOW\" OEM LETTER FROM MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.","solicitation_number":"36C24525Q0522","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-23T19:00:00Z","first_posted":"2025-05-14","last_posted":"2025-05-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":"WV","place_scope":"nationwide","site":"Beckley VA Medical Center","place_state_source":"sam_street","place_evidence":"BECKLEY VA MEDICAL CENTER BECKLEY, WV 25801","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"a729da5152774d5688b614fd7aedc66b","title":"6515--LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC. \"BRAND NAME OR EQUAL TO STRYKER IAW SOW\" OEM LETTER FROM MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.","solicitation_number":"36C24525Q0522","notice_type":"r","base_type":"r","posted":"2025-05-14","posted_at":"2025-05-14T12:49:21.259Z","due_at":"2025-05-23T19:00:00Z","due_date":"2025-05-23","cancelled":false,"archived":true,"archive_date":"2025-06-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a729da5152774d5688b614fd7aedc66b/view","enriched":true,"history":[{"index":3,"title":"6515--LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC. \"BRAND NAME OR EQUAL TO STRYKER IAW SOW\" OEM LETTER FROM MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T12:49:21.259Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a729da5152774d5688b614fd7aedc66b","solicitation_number":"36C24525Q0522"}]}],"latest_notice_id":"a729da5152774d5688b614fd7aedc66b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-05-14","posted_at":"2025-05-14T12:49:21.259Z","created_at":"2025-05-14T12:48:56.081Z","modified_at":"2025-06-03T03:55:52.948Z","response_deadline":{"raw":"2025-05-23T15:00:00-04:00","utc":"2025-05-23T19:00:00Z","date":"2025-05-23","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a729da5152774d5688b614fd7aedc66b/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC. \"BRAND NAME OR EQUAL TO STRYKER IAW SOW\" OEM LETTER FROM MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-02","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC. \"BRAND NAME OR EQUAL TO STRYKER IAW SOW\" OEM LETTER FROM MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-14T12:49:21.259Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"a729da5152774d5688b614fd7aedc66b","solicitation_number":"36C24525Q0522"}],"contacts":[{"name":"Mohsin Abbas","role":"primary","email":"Mohsin.Abbas2@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"a729da5152774d5688b614fd7aedc66b","lineage_id":"a729da5152774d5688b614fd7aedc66b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T03:30:51.921042687Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"51a049d0c932645a1d8f13088f65327c450d0cddcea0035d1a0c6aa6f6b19814","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T03:30:51.921042687Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\n LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC \n\n  BRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK \n\n OEM DISTRIBUTOR/ AUTHORIZATION LETTER FROM THE MANUFACTURER IS REQUIRED FOR ALL RESPONSES, IF NO OEM LETTER IS SUPPLIED THE VENDOR WILL BE CONSIDERED NON-RESPONSIVE AND THE VENDOR WILL BE DIS-QUALIFIED AT THE TIME RFI WILL CLOSE .\n\n MUST FULLY COMPLETE FAR 52.225-6   TRADE AGREEMENT CERTIFICATE  \n\nNOTICE: \n System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications  Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM. \n\nThis is a requirement for: \n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION: \n\nThe Beckley VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBeckley VA Medical Center\nWAREHOUSE/ATTN: \n200 Veterans Avenue\nBeckley, WV 25801\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government. \nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey. \nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded. \n** MUST ANSWER ALL THE FOLLOWING QUESTIONS ** \n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above? \n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly \n\n    (1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n          (2) __ Outside the United States.\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\n Legal Business/Company Name (as it is indicated in https://sam.gov ).\n\n Unique Entity ID UEI (SAM).\n\n Warranty Information (Can be a separate attachment).\n\n Point of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO. \n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase. \nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award. \n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov.  No Telephone responses shall not be accepted. Responses must be received no later than Friday, May 23, 2025, by 3:00 PM (EST). \n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\n\nSTATEMENT OF WORK (SOW)\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC.\n\nGENERAL:\nScope of Services:\nThe purpose of this requirement is to replace the failing laparoscopic towers for the Operating Rooms at the Beckley VA Medical Center. The requirement includes the cameras, controllers, carts, light sources, device controllers, transmitters, receivers, displays, insufflators, printers, and more for the three systems. The procurement shall include all parts, materials, labor, software/licenses, and travel to complete the full installation/configuration of the systems.\nLocation: 200 Veterans Ave, Beckley, WV 25801\nPerformance Period: Requested delivery within 90 days of award\nWORK HOURS:\nHours of Operation: Normal business hours are Monday through Friday, 8:00 a.m.  4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR).\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nNational Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.\n\nSPECIFICATIONS: \nTechnical Requirements\nThe procurement is for a brand name or equal solution for three comprehensive surgical video tower systems to be utilized during laparoscopic, sinuscopic, and arthroscopic cases.\nThe Stryker brand name components include:\nDescription/Part Number*\nQty\n1788010000\nPKG 1788 Camera Control Unit CCU\n3\n220240300\nPKG L12 LED LIGHT SOURCE WITH AIM\n3\n0240099110K\nFLAT PANEL ROLL STAND KIT\n1\n240200412\nConnected OR Hub Base System with Device Control and SDP1000 Printer\n3\n240031065\nPkg SYNK 4K Wireless Transmitter\n3\n240031075\nPkg SYNK 4K Wireless Receiver\n3\n240031311\n32IN 4K OLED Surgical Display with OLED Display Cover Kit\n6\n1788610122\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER\n10\n233050400\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\n10\n0502-103-010\nPRECISION IDEAL EYES 10MM 0Â° HD AC LPSC\n6\n0502-103-030\nPRECISION IDEAL EYES 10MM 30Â° HD AC LPSC\n6\n0502-503-010\nPRECISION IDEAL EYES 5.5 0Â° HD ACL LAP30\n6\n0502-503-030\nPRECISION IDEAL EYE 5.5 30Â° HD ACL LAP30\n6\n240-099-155\nConnected OR Cart 120 V\n3\n620050001\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS\n3\n0502-444-030\nPRECISION IE 4K EYPC ASC ATCL4X30Â°140SLK\n8\n0502-444-070\nPRECISION IE 4K EYPC ASC ATCL4X70Â°140SLK\n3\n0502-127-030\nHD 2.7MMX30Ã‚Â° ARTHROSCOPE SPEEDLOCK A/C\n1\n747031530\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST\n11\n747031510\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA\n11\n0343-331-430\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES\n1\n0343-331-410\nPKG. OBTURATOR 4.0MM PENCIL TIP\n1\n0502-655-010\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0Ã‚Â°, 180mm Ã‚Â \n3\n0502-654-045\nPRECISION S 4K SINUSCOPE, ACLV,4X45Â°,155\n3\n0502-654-070\nPRECISION S 4K SINUSCOPE, ACLV,4X70Â°,155\n3\n0502652010K\n0502652010 Sinuscope and 0502752010 Sheath Kit\n3\n0502652030K\n0502652030 Sinuscope and 0502752030 Sheath Kit\n3\n233032105\nENDOSCOPE AND CAMERA STERILIZATION TRAY\n10\n233032108\nPKG LAPAROSCOPE STERILIZATION TRAY\n10\n233032116\nENDOSCOPE AND HARDWARE SET TRAY\n12\n\nThe systems shall be able to perform the video visualization function for all laparoscopic, sinuscopic, and arthroscopic cases at the Beckley VAMC.\nThe three systems shall be on towers/carts to allow for mobility in the operating room.\nThe system shall have advanced visualization/quality.\nThe system shall have the ability for visualizing perfusion during open surgery.\nThe systems shall include 2, 32inch, 4K, OLED displays. One located on the scope tower and the other to be located on an existing equipment boom.\nThe systems  insufflators are preferred to have integrated heating, humidification, and smoke evacuation.\nThe system shall offer a means to export captured images off the device to be later scanned and manually uploaded into the VA EMR. \nThe provided boom mounted monitors shall be able to connect to the existing Steris video integration system for displaying video/images in the ORs via a hardwired connection (i.e. HDMI).\nContractor shall provide two copies of the operating and service manuals.\nScope Requirements\n\nLaparoscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n10\n330\n0\n75\nHD\nAutoclavable\n5\n10\n330\n30\n75\nHD\nAutoclavable\n5\n5\n300\n0\n75\nHD\nAutoclavable\n5\n5\n300\n30\n75\nHD\nAutoclavable\n5\n\nArthroscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nLock Type\nDefinition\nCleaning\nQuantity\n4\n140 mm\n0 deg\nSpeedlock\n4K\nAutoclavable\nÂ 8\n4\n140 mm\n70 deg\nSpeedlock\n4K\nAutoclavable\nÂ 3\n\nSinuscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n4\n180\n0\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n45\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n70\n105\n4K\nAutoclavable\nÂ 3\n3.1\n170\n0\n80\n4K\nAutoclavable\nÂ 3\n3.1\n170\n30\n80\n4K\nAutoclavable\nÂ 3\n\nNetworking Requirements.\nConnection to the VA network is NOT a requirement. \nIf the proposed solution requires a VA network connection to operate, the vendor will be required to complete the VA s required documentation. \nShould the manufacturer of the equipment not have an approved Enterprise Risk Analysis completed, this will be required in order to fully install the system on the network.\nOnly OEM-supported operating systems shall be provided\nFollowing purchase, the VA will provide specific network information for the configuration of the system.\nIf remote support is required, the Contractor must have a completed MOU/ISA.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use   IFU) for the Government to determine the ability of the facility to properly process the equipment.\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nLarge deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place.\nContractor is to provide the COR with shipment tracking information.\nInstallation Requirements\nFull installation of the system shall be included as a part of this contract. This will include, but not be limited to: \nAssembly and configuration of scope towers\nMounting of monitors on existing equipment booms. Contractor shall provide new mounting brackets if existing bracket cannot support the new monitors. Contractor to utilize existing power present in the boom. \nAll parts, materials, tools, labor, and travel to complete the installation shall be included as a part of this contract.\nContractor is required to complete all configuration for the system to be usable.\nContractor shall provide validation that the system is fully functional upon completion of the installation/implementation.\nPatient Health Information\nThe Contractor shall safeguard patient health information.\nThe Contractor shall report to the Biomedical Engineering Department any issues with disclosed or unsecure patient health information.\nContractor shall not remove any hard-drives or storage systems containing sensitive or patient health information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device, in addition to any software/applications.\nTraining shall be on-site for one day.\nContract shall include training for the technical professionals (Biomedical Equipment Support Specialists)\nTraining shall cover the maintenance, troubleshooting, and repair of the system.\nTraining shall be on-site for one day.\nContractor Requirements\nAll Contractor personnel performing installation services of the equipment shall have factory training and experience in the implementation of the equipment.\nContractor shall provide copies of training certificates for the Contractor personnel performing work on-site upon the request of the Government.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall perform any available system updates during the warranty period at the discretion of Biomedical Engineering.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided.\nOn-Site Procedures\nContractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department.\nContractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information.\nContractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure.\nContractor personnel shall sign out upon completion of visit.\nPrior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking. It is the responsibility of the Contractor to park in the appropriate desig nated park ing areas.\nSafety and Security\nContractor shall follow all Occupational Safety and Health Administration (OSHA) laws and regulations. The Contractor is responsible for reporting any hazards they come across to their point of contact.\nContractor shall follow all local procedures concerning infection control. Should the Contractor be unsure of the requirements, the COR can provide the specific information and procedures.\nContractor personnel shall wear visible identification at all times while on VA property. Contract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials.\nProperty Damage\nThe contractor shall take all necessary precautions to prevent damage to any Government property.\nThe contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken.\nAny damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the Government, upon approval of the Contracting Officer.\n\nQUALITY ASSURANCE\nEnd-users, Biomedical Engineering, and/or the contract COR shall perform system verification tests to ensure the system is fully functional.\nIssues with the quality of the Contractor s work will be communicated through the Contracting Officer to the Contractor point of contact for resolution.\nDocumentation with be completed in the Government systems.\n\nEVALUATION FACTORS\nLAPAROSCOPIC SYSTEM - BECKLEY VA MEDICAL CENTER\nVolume I - Technical Capability\nThe offeror shall provide technical information regarding its proposed laparoscopic system solution as described in the Statement of Work with technical information required to include the following:\nAbility to provide all of the required components of the laparoscopic system, clearly noting any deviations from the items, dimensions, features, etc. for any parts\nDemonstrate the camera system visualization quality\nDemonstrate the ability for visualizing perfusion during open surgery\nProvide information on the surgical monitor size and quality\nExplain the fluorescence imaging capabilities and quality\nProvide information on the insufflator s features\nConfirm ability to connect to existing Steris video integration system\nProvide the Instructions for Use (IFU) or Cleaning Instructions for reprocessed/reused parts\n\nVolume II   Price\nPrice - The offeror shall complete the pricing schedule provided in the above: Price/Cost Schedule.\nVolume III   Past Performance\nThe offeror shall submit three (3) past performance references that are recent and relevant which focuses on experience within the last five (5) years in hospital settings that are comparable in size as the Beckley VA Medical Center. References shall include the contract number for the project, a brief description, and a point of contact to include an email address. The information shall be provided in 5 pages or less.\nPast Performance- Acceptable or Unacceptable Rating\nThe Government shall make an objective assessment of the Offeror's current/past performance. It will conduct a performance acceptable assessment based on aspects of offeror's past performance that are recent and relevant which focuses on experience within the last 5 years in the hospital settings that are comparable in size as VA Capitol Health Care Network (VISN 5) or larger which contain Operating Rooms, PACUs and other critical care areas. They have to be relevant, similar in complexity, and magnitude requirements of solicitation. Performance that are not recent, relevant, similar in complexity or magnitude will be evaluated with unacceptable performance in this area.\nVolume IV   Must Complete the Trade Agreement Certificate.\nMust complete the Trade Agreement Certificate to provide the country of origin (COO) for all the line-items. \nVolume V   Must provide an OEM Authorized Distributor Letter from the manufacturer\nMust provide the OEM from the manufacturer, if no OEM letter from the manufacturer is supplied. The vendor will be considered non-responsive, and the vendor will be dis-qualified at the time request for Information (RFI) will close. \n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nLINE-ITEM DESCRIPTION\n\n LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC \n\n  BRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK \nB.1 PRICE/COST SCHEDULE\nITEM INFORMATION\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\n\nQUANTITY\n\nUNIT\n\nUNIT PRICE\n\nAMOUNT\n0001\n\n3.00\nEA\n  \n  \n\nPKG 1788 Camera Control Unit CCU CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788010000 LOCAL STOCK NUMBER: 1788010000\n\n0002\n\n3.00\nEA\n  \n  \n\nPKG L12 LED LIGHT SOURCE WITH AIM CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 220240300 LOCAL STOCK NUMBER: 220240300\n\n0003\n\n1.00\nEA\n  \n  \n\nFLAT PANEL ROLL STAND KIT CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0240099110K\n\n\nLOCAL STOCK NUMBER: 0240099110K\n0004\n3.00\nEA\n  \n  \nConnected OR Hub Base System with Device Control and SDP1000 Printer\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240200412 LOCAL STOCK NUMBER: 240200412\n\n0005\n3.00\nEA\n  \n  \nPkg SYNK 4K Wireless Transmitter CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031065 LOCAL STOCK NUMBER: 240031065\n\n0006\n3.00\nEA\n  \n  \nPkg SYNK 4K Wireless Receiver CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031075 LOCAL STOCK NUMBER: 240031075\n\n\n0007\n6.00\nEA\n  \n  \n32IN 4K OLED Surgical Display with OLED Display Cover Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031311 LOCAL STOCK NUMBER: 240031311\n\n0008\n10.00\nEA\n  \n  \nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788610122 LOCAL STOCK NUMBER: 1788610122\n\n0009\n10.00\nEA\n  \n  \nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233050400 LOCAL STOCK NUMBER: 233050400\n\n0010\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 10MM 0? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\n\n\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-010 LOCAL STOCK NUMBER: 0502-103-010\n0011\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 10MM 30? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-030 LOCAL STOCK NUMBER: 0502-103-030\n\n0012\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 5.5 0? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-503-010 LOCAL STOCK NUMBER: 0502-503-010\n\n0013\n6.00\nEA\n  \n  \nPRECISION IDEAL EYE 5.5 30? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments,\nEquipment, and Supplies\n\n\nMANUFACTURER PART NUMBER (MPN): 0502-503-030 LOCAL STOCK NUMBER: 0502-503-030\n0014\n3.00\nEA\n  \n  \nConnected OR Cart 120 V CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240-099-155 LOCAL STOCK NUMBER: 240-099-155\n\n0015\n3.00\nEA\n  \n  \nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 620050001 LOCAL STOCK NUMBER: 620050001\n\n0016\n8.00\nEA\n  \n  \nPRECISION IE 4K EYPC ASC ATCL4X30?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-030 LOCAL STOCK NUMBER: 0502-444-030\n\n\n0017\n3.00\nEA\n  \n  \nPRECISION IE 4K EYPC ASC ATCL4X70?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-070 LOCAL STOCK NUMBER: 0502-444-070\n\n0018\n1.00\nEA\n  \n  \nHD 2.7MMX30A ARTHROSCOPE SPEEDLOCK A/C CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-127-030 LOCAL STOCK NUMBER: 0502-127-030\n\n0019\n11.00\nEA\n  \n  \nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031530 LOCAL STOCK NUMBER: 747031530\n\n0020\n11.00\nEA\n  \n  \nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\n\n\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031510 LOCAL STOCK NUMBER: 747031510\n0021\n1.00\nEA\n  \n  \nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-430 LOCAL STOCK NUMBER: 0343-331-430\n\n0022\n1.00\nEA\n  \n  \nPKG. OBTURATOR 4.0MM PENCIL TIP CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-410 LOCAL STOCK NUMBER: 0343-331-410\n\n0023\n3.00\nEA\n  \n  \nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0A, 180mm A CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-655-010\n\n\nLOCAL STOCK NUMBER: 0502-655-010\n0024\n3.00\nEA\n  \n  \nPRECISION S 4K SINUSCOPE, ACLV,4X45,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-045 LOCAL STOCK NUMBER: 0502-654-045\n\n0025\n3.00\nEA\n  \n  \nPRECISION S 4K SINUSCOPE, ACLV,4X70?,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-070 LOCAL STOCK NUMBER: 0502-654-070\n\n0026\n3.00\nEA\n  \n  \n0502652010 Sinuscope and 0502752010 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652010K LOCAL STOCK NUMBER: 0502652010K\n\n0027\n3.00\nEA\n  \n  \n\n0502652030 Sinuscope and 0502752030 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652030K LOCAL STOCK NUMBER: 0502652030K\n0028\n10.00\nEA\n  \n  \nENDOSCOPE AND CAMERA STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032105 LOCAL STOCK NUMBER: 233032105\n\n0029\n10.00\nEA\n  \n  \nPKG LAPAROSCOPE STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032108 LOCAL STOCK NUMBER: 233032108\n\n0030\n12.00\nEA\n  \n  \nENDOSCOPE AND HARDWARE SET TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\n\n\n\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032116 LOCAL STOCK NUMBER: 233032116\n\nGRAND TOTAL","text":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC\n\nBRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK\n\nOEM DISTRIBUTOR/ AUTHORIZATION LETTER FROM THE MANUFACTURER IS REQUIRED FOR ALL RESPONSES, IF NO OEM LETTER IS SUPPLIED THE VENDOR WILL BE CONSIDERED NON-RESPONSIVE AND THE VENDOR WILL BE DIS-QUALIFIED AT THE TIME RFI WILL CLOSE .\n\nMUST FULLY COMPLETE FAR 52.225-6 TRADE AGREEMENT CERTIFICATE\n\nNOTICE:\nSystem updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.\n\nThis is a requirement for:\n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION:\n\nThe Beckley VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBeckley VA Medical Center\nWAREHOUSE/ATTN:\n200 Veterans Avenue\nBeckley, WV 25801\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government.\nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey.\nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded.\n** MUST ANSWER ALL THE FOLLOWING QUESTIONS **\n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above?\n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly\n\n(1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n(2) __ Outside the United States.\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nLegal Business/Company Name (as it is indicated in https://sam.gov ).\n\nUnique Entity ID UEI (SAM).\n\nWarranty Information (Can be a separate attachment).\n\nPoint of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO.\n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase.\nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award.\n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov. No Telephone responses shall not be accepted. Responses must be received no later than Friday, May 23, 2025, by 3:00 PM (EST).\n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\nSTATEMENT OF WORK (SOW)\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC.\n\nGENERAL:\nScope of Services:\nThe purpose of this requirement is to replace the failing laparoscopic towers for the Operating Rooms at the Beckley VA Medical Center. The requirement includes the cameras, controllers, carts, light sources, device controllers, transmitters, receivers, displays, insufflators, printers, and more for the three systems. The procurement shall include all parts, materials, labor, software/licenses, and travel to complete the full installation/configuration of the systems.\nLocation: 200 Veterans Ave, Beckley, WV 25801\nPerformance Period: Requested delivery within 90 days of award\nWORK HOURS:\nHours of Operation: Normal business hours are Monday through Friday, 8:00 a.m. 4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR).\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nNational Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.\n\nSPECIFICATIONS:\nTechnical Requirements\nThe procurement is for a brand name or equal solution for three comprehensive surgical video tower systems to be utilized during laparoscopic, sinuscopic, and arthroscopic cases.\nThe Stryker brand name components include:\nDescription/Part Number*\nQty\n1788010000\nPKG 1788 Camera Control Unit CCU\n3\n220240300\nPKG L12 LED LIGHT SOURCE WITH AIM\n3\n0240099110K\nFLAT PANEL ROLL STAND KIT\n1\n240200412\nConnected OR Hub Base System with Device Control and SDP1000 Printer\n3\n240031065\nPkg SYNK 4K Wireless Transmitter\n3\n240031075\nPkg SYNK 4K Wireless Receiver\n3\n240031311\n32IN 4K OLED Surgical Display with OLED Display Cover Kit\n6\n1788610122\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER\n10\n233050400\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\n10\n0502-103-010\nPRECISION IDEAL EYES 10MM 0Â° HD AC LPSC\n6\n0502-103-030\nPRECISION IDEAL EYES 10MM 30Â° HD AC LPSC\n6\n0502-503-010\nPRECISION IDEAL EYES 5.5 0Â° HD ACL LAP30\n6\n0502-503-030\nPRECISION IDEAL EYE 5.5 30Â° HD ACL LAP30\n6\n240-099-155\nConnected OR Cart 120 V\n3\n620050001\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS\n3\n0502-444-030\nPRECISION IE 4K EYPC ASC ATCL4X30Â°140SLK\n8\n0502-444-070\nPRECISION IE 4K EYPC ASC ATCL4X70Â°140SLK\n3\n0502-127-030\nHD 2.7MMX30Ã‚Â° ARTHROSCOPE SPEEDLOCK A/C\n1\n747031530\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST\n11\n747031510\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA\n11\n0343-331-430\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES\n1\n0343-331-410\nPKG. OBTURATOR 4.0MM PENCIL TIP\n1\n0502-655-010\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0Ã‚Â°, 180mm Ã‚Â\n3\n0502-654-045\nPRECISION S 4K SINUSCOPE, ACLV,4X45Â°,155\n3\n0502-654-070\nPRECISION S 4K SINUSCOPE, ACLV,4X70Â°,155\n3\n0502652010K\n0502652010 Sinuscope and 0502752010 Sheath Kit\n3\n0502652030K\n0502652030 Sinuscope and 0502752030 Sheath Kit\n3\n233032105\nENDOSCOPE AND CAMERA STERILIZATION TRAY\n10\n233032108\nPKG LAPAROSCOPE STERILIZATION TRAY\n10\n233032116\nENDOSCOPE AND HARDWARE SET TRAY\n12\n\nThe systems shall be able to perform the video visualization function for all laparoscopic, sinuscopic, and arthroscopic cases at the Beckley VAMC.\nThe three systems shall be on towers/carts to allow for mobility in the operating room.\nThe system shall have advanced visualization/quality.\nThe system shall have the ability for visualizing perfusion during open surgery.\nThe systems shall include 2, 32inch, 4K, OLED displays. One located on the scope tower and the other to be located on an existing equipment boom.\nThe systems insufflators are preferred to have integrated heating, humidification, and smoke evacuation.\nThe system shall offer a means to export captured images off the device to be later scanned and manually uploaded into the VA EMR.\nThe provided boom mounted monitors shall be able to connect to the existing Steris video integration system for displaying video/images in the ORs via a hardwired connection (i.e. HDMI).\nContractor shall provide two copies of the operating and service manuals.\nScope Requirements\n\nLaparoscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n10\n330\n0\n75\nHD\nAutoclavable\n5\n10\n330\n30\n75\nHD\nAutoclavable\n5\n5\n300\n0\n75\nHD\nAutoclavable\n5\n5\n300\n30\n75\nHD\nAutoclavable\n5\n\nArthroscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nLock Type\nDefinition\nCleaning\nQuantity\n4\n140 mm\n0 deg\nSpeedlock\n4K\nAutoclavable\nÂ 8\n4\n140 mm\n70 deg\nSpeedlock\n4K\nAutoclavable\nÂ 3\n\nSinuscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n4\n180\n0\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n45\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n70\n105\n4K\nAutoclavable\nÂ 3\n3.1\n170\n0\n80\n4K\nAutoclavable\nÂ 3\n3.1\n170\n30\n80\n4K\nAutoclavable\nÂ 3\n\nNetworking Requirements.\nConnection to the VA network is NOT a requirement.\nIf the proposed solution requires a VA network connection to operate, the vendor will be required to complete the VA s required documentation.\nShould the manufacturer of the equipment not have an approved Enterprise Risk Analysis completed, this will be required in order to fully install the system on the network.\nOnly OEM-supported operating systems shall be provided\nFollowing purchase, the VA will provide specific network information for the configuration of the system.\nIf remote support is required, the Contractor must have a completed MOU/ISA.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use IFU) for the Government to determine the ability of the facility to properly process the equipment.\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nLarge deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place.\nContractor is to provide the COR with shipment tracking information.\nInstallation Requirements\nFull installation of the system shall be included as a part of this contract. This will include, but not be limited to:\nAssembly and configuration of scope towers\nMounting of monitors on existing equipment booms. Contractor shall provide new mounting brackets if existing bracket cannot support the new monitors. Contractor to utilize existing power present in the boom.\nAll parts, materials, tools, labor, and travel to complete the installation shall be included as a part of this contract.\nContractor is required to complete all configuration for the system to be usable.\nContractor shall provide validation that the system is fully functional upon completion of the installation/implementation.\nPatient Health Information\nThe Contractor shall safeguard patient health information.\nThe Contractor shall report to the Biomedical Engineering Department any issues with disclosed or unsecure patient health information.\nContractor shall not remove any hard-drives or storage systems containing sensitive or patient health information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device, in addition to any software/applications.\nTraining shall be on-site for one day.\nContract shall include training for the technical professionals (Biomedical Equipment Support Specialists)\nTraining shall cover the maintenance, troubleshooting, and repair of the system.\nTraining shall be on-site for one day.\nContractor Requirements\nAll Contractor personnel performing installation services of the equipment shall have factory training and experience in the implementation of the equipment.\nContractor shall provide copies of training certificates for the Contractor personnel performing work on-site upon the request of the Government.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall perform any available system updates during the warranty period at the discretion of Biomedical Engineering.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided.\nOn-Site Procedures\nContractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department.\nContractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information.\nContractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure.\nContractor personnel shall sign out upon completion of visit.\nPrior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking. It is the responsibility of the Contractor to park in the appropriate desig nated park ing areas.\nSafety and Security\nContractor shall follow all Occupational Safety and Health Administration (OSHA) laws and regulations. The Contractor is responsible for reporting any hazards they come across to their point of contact.\nContractor shall follow all local procedures concerning infection control. Should the Contractor be unsure of the requirements, the COR can provide the specific information and procedures.\nContractor personnel shall wear visible identification at all times while on VA property. Contract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials.\nProperty Damage\nThe contractor shall take all necessary precautions to prevent damage to any Government property.\nThe contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken.\nAny damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the Government, upon approval of the Contracting Officer.\n\nQUALITY ASSURANCE\nEnd-users, Biomedical Engineering, and/or the contract COR shall perform system verification tests to ensure the system is fully functional.\nIssues with the quality of the Contractor s work will be communicated through the Contracting Officer to the Contractor point of contact for resolution.\nDocumentation with be completed in the Government systems.\n\nEVALUATION FACTORS\nLAPAROSCOPIC SYSTEM - BECKLEY VA MEDICAL CENTER\nVolume I - Technical Capability\nThe offeror shall provide technical information regarding its proposed laparoscopic system solution as described in the Statement of Work with technical information required to include the following:\nAbility to provide all of the required components of the laparoscopic system, clearly noting any deviations from the items, dimensions, features, etc. for any parts\nDemonstrate the camera system visualization quality\nDemonstrate the ability for visualizing perfusion during open surgery\nProvide information on the surgical monitor size and quality\nExplain the fluorescence imaging capabilities and quality\nProvide information on the insufflator s features\nConfirm ability to connect to existing Steris video integration system\nProvide the Instructions for Use (IFU) or Cleaning Instructions for reprocessed/reused parts\n\nVolume II Price\nPrice - The offeror shall complete the pricing schedule provided in the above: Price/Cost Schedule.\nVolume III Past Performance\nThe offeror shall submit three (3) past performance references that are recent and relevant which focuses on experience within the last five (5) years in hospital settings that are comparable in size as the Beckley VA Medical Center. References shall include the contract number for the project, a brief description, and a point of contact to include an email address. The information shall be provided in 5 pages or less.\nPast Performance- Acceptable or Unacceptable Rating\nThe Government shall make an objective assessment of the Offeror's current/past performance. It will conduct a performance acceptable assessment based on aspects of offeror's past performance that are recent and relevant which focuses on experience within the last 5 years in the hospital settings that are comparable in size as VA Capitol Health Care Network (VISN 5) or larger which contain Operating Rooms, PACUs and other critical care areas. They have to be relevant, similar in complexity, and magnitude requirements of solicitation. Performance that are not recent, relevant, similar in complexity or magnitude will be evaluated with unacceptable performance in this area.\nVolume IV Must Complete the Trade Agreement Certificate.\nMust complete the Trade Agreement Certificate to provide the country of origin (COO) for all the line-items.\nVolume V Must provide an OEM Authorized Distributor Letter from the manufacturer\nMust provide the OEM from the manufacturer, if no OEM letter from the manufacturer is supplied. The vendor will be considered non-responsive, and the vendor will be dis-qualified at the time request for Information (RFI) will close.\n\nLINE-ITEM DESCRIPTION\n\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC\n\nBRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK\nB.1 PRICE/COST SCHEDULE\nITEM INFORMATION\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\n\nQUANTITY\n\nUNIT\n\nUNIT PRICE\n\nAMOUNT\n0001\n\n3.00\nEA\n\nPKG 1788 Camera Control Unit CCU CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788010000 LOCAL STOCK NUMBER: 1788010000\n\n0002\n\n3.00\nEA\n\nPKG L12 LED LIGHT SOURCE WITH AIM CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 220240300 LOCAL STOCK NUMBER: 220240300\n\n0003\n\n1.00\nEA\n\nFLAT PANEL ROLL STAND KIT CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0240099110K\n\nLOCAL STOCK NUMBER: 0240099110K\n0004\n3.00\nEA\n\nConnected OR Hub Base System with Device Control and SDP1000 Printer\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240200412 LOCAL STOCK NUMBER: 240200412\n\n0005\n3.00\nEA\n\nPkg SYNK 4K Wireless Transmitter CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031065 LOCAL STOCK NUMBER: 240031065\n\n0006\n3.00\nEA\n\nPkg SYNK 4K Wireless Receiver CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031075 LOCAL STOCK NUMBER: 240031075\n\n0007\n6.00\nEA\n\n32IN 4K OLED Surgical Display with OLED Display Cover Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031311 LOCAL STOCK NUMBER: 240031311\n\n0008\n10.00\nEA\n\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788610122 LOCAL STOCK NUMBER: 1788610122\n\n0009\n10.00\nEA\n\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233050400 LOCAL STOCK NUMBER: 233050400\n\n0010\n6.00\nEA\n\nPRECISION IDEAL EYES 10MM 0? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-010 LOCAL STOCK NUMBER: 0502-103-010\n0011\n6.00\nEA\n\nPRECISION IDEAL EYES 10MM 30? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-030 LOCAL STOCK NUMBER: 0502-103-030\n\n0012\n6.00\nEA\n\nPRECISION IDEAL EYES 5.5 0? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-503-010 LOCAL STOCK NUMBER: 0502-503-010\n\n0013\n6.00\nEA\n\nPRECISION IDEAL EYE 5.5 30? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments,\nEquipment, and Supplies\n\nMANUFACTURER PART NUMBER (MPN): 0502-503-030 LOCAL STOCK NUMBER: 0502-503-030\n0014\n3.00\nEA\n\nConnected OR Cart 120 V CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240-099-155 LOCAL STOCK NUMBER: 240-099-155\n\n0015\n3.00\nEA\n\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 620050001 LOCAL STOCK NUMBER: 620050001\n\n0016\n8.00\nEA\n\nPRECISION IE 4K EYPC ASC ATCL4X30?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-030 LOCAL STOCK NUMBER: 0502-444-030\n\n0017\n3.00\nEA\n\nPRECISION IE 4K EYPC ASC ATCL4X70?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-070 LOCAL STOCK NUMBER: 0502-444-070\n\n0018\n1.00\nEA\n\nHD 2.7MMX30A ARTHROSCOPE SPEEDLOCK A/C CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-127-030 LOCAL STOCK NUMBER: 0502-127-030\n\n0019\n11.00\nEA\n\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031530 LOCAL STOCK NUMBER: 747031530\n\n0020\n11.00\nEA\n\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\n\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031510 LOCAL STOCK NUMBER: 747031510\n0021\n1.00\nEA\n\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-430 LOCAL STOCK NUMBER: 0343-331-430\n\n0022\n1.00\nEA\n\nPKG. OBTURATOR 4.0MM PENCIL TIP CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-410 LOCAL STOCK NUMBER: 0343-331-410\n\n0023\n3.00\nEA\n\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0A, 180mm A CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-655-010\n\nLOCAL STOCK NUMBER: 0502-655-010\n0024\n3.00\nEA\n\nPRECISION S 4K SINUSCOPE, ACLV,4X45,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-045 LOCAL STOCK NUMBER: 0502-654-045\n\n0025\n3.00\nEA\n\nPRECISION S 4K SINUSCOPE, ACLV,4X70?,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-070 LOCAL STOCK NUMBER: 0502-654-070\n\n0026\n3.00\nEA\n\n0502652010 Sinuscope and 0502752010 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652010K LOCAL STOCK NUMBER: 0502652010K\n\n0027\n3.00\nEA\n\n0502652030 Sinuscope and 0502752030 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652030K LOCAL STOCK NUMBER: 0502652030K\n0028\n10.00\nEA\n\nENDOSCOPE AND CAMERA STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032105 LOCAL STOCK NUMBER: 233032105\n\n0029\n10.00\nEA\n\nPKG LAPAROSCOPE STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032108 LOCAL STOCK NUMBER: 233032108\n\n0030\n12.00\nEA\n\nENDOSCOPE AND HARDWARE SET TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\n\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032116 LOCAL STOCK NUMBER: 233032116\n\nGRAND TOTAL","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0522","place_of_performance":{"street":"Beckley VA Medical Center Beckley, WV 25801"},"product_service_code":"6515"}],"due_at":"2025-05-23T19:00:00Z","due_date":"2025-05-23","closes_at":"2025-05-23T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"BECKLEY VA MEDICAL CENTER BECKLEY, WV 25801","site_key":"beckley-va-medical-center-wv","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-15T04:08:10.553974Z","principal_notice_id":"a729da5152774d5688b614fd7aedc66b","description":{"text":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC\n\nBRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK\n\nOEM DISTRIBUTOR/ AUTHORIZATION LETTER FROM THE MANUFACTURER IS REQUIRED FOR ALL RESPONSES, IF NO OEM LETTER IS SUPPLIED THE VENDOR WILL BE CONSIDERED NON-RESPONSIVE AND THE VENDOR WILL BE DIS-QUALIFIED AT THE TIME RFI WILL CLOSE .\n\nMUST FULLY COMPLETE FAR 52.225-6 TRADE AGREEMENT CERTIFICATE\n\nNOTICE:\nSystem updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.\n\nThis is a requirement for:\n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION:\n\nThe Beckley VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBeckley VA Medical Center\nWAREHOUSE/ATTN:\n200 Veterans Avenue\nBeckley, WV 25801\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government.\nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey.\nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded.\n** MUST ANSWER ALL THE FOLLOWING QUESTIONS **\n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above?\n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly\n\n(1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n(2) __ Outside the United States.\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nLegal Business/Company Name (as it is indicated in https://sam.gov ).\n\nUnique Entity ID UEI (SAM).\n\nWarranty Information (Can be a separate attachment).\n\nPoint of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO.\n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase.\nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award.\n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov. No Telephone responses shall not be accepted. Responses must be received no later than Friday, May 23, 2025, by 3:00 PM (EST).\n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\nSTATEMENT OF WORK (SOW)\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC.\n\nGENERAL:\nScope of Services:\nThe purpose of this requirement is to replace the failing laparoscopic towers for the Operating Rooms at the Beckley VA Medical Center. The requirement includes the cameras, controllers, carts, light sources, device controllers, transmitters, receivers, displays, insufflators, printers, and more for the three systems. The procurement shall include all parts, materials, labor, software/licenses, and travel to complete the full installation/configuration of the systems.\nLocation: 200 Veterans Ave, Beckley, WV 25801\nPerformance Period: Requested delivery within 90 days of award\nWORK HOURS:\nHours of Operation: Normal business hours are Monday through Friday, 8:00 a.m. 4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR).\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nNational Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.\n\nSPECIFICATIONS:\nTechnical Requirements\nThe procurement is for a brand name or equal solution for three comprehensive surgical video tower systems to be utilized during laparoscopic, sinuscopic, and arthroscopic cases.\nThe Stryker brand name components include:\nDescription/Part Number*\nQty\n1788010000\nPKG 1788 Camera Control Unit CCU\n3\n220240300\nPKG L12 LED LIGHT SOURCE WITH AIM\n3\n0240099110K\nFLAT PANEL ROLL STAND KIT\n1\n240200412\nConnected OR Hub Base System with Device Control and SDP1000 Printer\n3\n240031065\nPkg SYNK 4K Wireless Transmitter\n3\n240031075\nPkg SYNK 4K Wireless Receiver\n3\n240031311\n32IN 4K OLED Surgical Display with OLED Display Cover Kit\n6\n1788610122\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER\n10\n233050400\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\n10\n0502-103-010\nPRECISION IDEAL EYES 10MM 0Â° HD AC LPSC\n6\n0502-103-030\nPRECISION IDEAL EYES 10MM 30Â° HD AC LPSC\n6\n0502-503-010\nPRECISION IDEAL EYES 5.5 0Â° HD ACL LAP30\n6\n0502-503-030\nPRECISION IDEAL EYE 5.5 30Â° HD ACL LAP30\n6\n240-099-155\nConnected OR Cart 120 V\n3\n620050001\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS\n3\n0502-444-030\nPRECISION IE 4K EYPC ASC ATCL4X30Â°140SLK\n8\n0502-444-070\nPRECISION IE 4K EYPC ASC ATCL4X70Â°140SLK\n3\n0502-127-030\nHD 2.7MMX30Ã‚Â° ARTHROSCOPE SPEEDLOCK A/C\n1\n747031530\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST\n11\n747031510\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA\n11\n0343-331-430\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES\n1\n0343-331-410\nPKG. OBTURATOR 4.0MM PENCIL TIP\n1\n0502-655-010\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0Ã‚Â°, 180mm Ã‚Â\n3\n0502-654-045\nPRECISION S 4K SINUSCOPE, ACLV,4X45Â°,155\n3\n0502-654-070\nPRECISION S 4K SINUSCOPE, ACLV,4X70Â°,155\n3\n0502652010K\n0502652010 Sinuscope and 0502752010 Sheath Kit\n3\n0502652030K\n0502652030 Sinuscope and 0502752030 Sheath Kit\n3\n233032105\nENDOSCOPE AND CAMERA STERILIZATION TRAY\n10\n233032108\nPKG LAPAROSCOPE STERILIZATION TRAY\n10\n233032116\nENDOSCOPE AND HARDWARE SET TRAY\n12\n\nThe systems shall be able to perform the video visualization function for all laparoscopic, sinuscopic, and arthroscopic cases at the Beckley VAMC.\nThe three systems shall be on towers/carts to allow for mobility in the operating room.\nThe system shall have advanced visualization/quality.\nThe system shall have the ability for visualizing perfusion during open surgery.\nThe systems shall include 2, 32inch, 4K, OLED displays. One located on the scope tower and the other to be located on an existing equipment boom.\nThe systems insufflators are preferred to have integrated heating, humidification, and smoke evacuation.\nThe system shall offer a means to export captured images off the device to be later scanned and manually uploaded into the VA EMR.\nThe provided boom mounted monitors shall be able to connect to the existing Steris video integration system for displaying video/images in the ORs via a hardwired connection (i.e. HDMI).\nContractor shall provide two copies of the operating and service manuals.\nScope Requirements\n\nLaparoscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n10\n330\n0\n75\nHD\nAutoclavable\n5\n10\n330\n30\n75\nHD\nAutoclavable\n5\n5\n300\n0\n75\nHD\nAutoclavable\n5\n5\n300\n30\n75\nHD\nAutoclavable\n5\n\nArthroscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nLock Type\nDefinition\nCleaning\nQuantity\n4\n140 mm\n0 deg\nSpeedlock\n4K\nAutoclavable\nÂ 8\n4\n140 mm\n70 deg\nSpeedlock\n4K\nAutoclavable\nÂ 3\n\nSinuscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n4\n180\n0\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n45\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n70\n105\n4K\nAutoclavable\nÂ 3\n3.1\n170\n0\n80\n4K\nAutoclavable\nÂ 3\n3.1\n170\n30\n80\n4K\nAutoclavable\nÂ 3\n\nNetworking Requirements.\nConnection to the VA network is NOT a requirement.\nIf the proposed solution requires a VA network connection to operate, the vendor will be required to complete the VA s required documentation.\nShould the manufacturer of the equipment not have an approved Enterprise Risk Analysis completed, this will be required in order to fully install the system on the network.\nOnly OEM-supported operating systems shall be provided\nFollowing purchase, the VA will provide specific network information for the configuration of the system.\nIf remote support is required, the Contractor must have a completed MOU/ISA.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use IFU) for the Government to determine the ability of the facility to properly process the equipment.\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nLarge deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place.\nContractor is to provide the COR with shipment tracking information.\nInstallation Requirements\nFull installation of the system shall be included as a part of this contract. This will include, but not be limited to:\nAssembly and configuration of scope towers\nMounting of monitors on existing equipment booms. Contractor shall provide new mounting brackets if existing bracket cannot support the new monitors. Contractor to utilize existing power present in the boom.\nAll parts, materials, tools, labor, and travel to complete the installation shall be included as a part of this contract.\nContractor is required to complete all configuration for the system to be usable.\nContractor shall provide validation that the system is fully functional upon completion of the installation/implementation.\nPatient Health Information\nThe Contractor shall safeguard patient health information.\nThe Contractor shall report to the Biomedical Engineering Department any issues with disclosed or unsecure patient health information.\nContractor shall not remove any hard-drives or storage systems containing sensitive or patient health information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device, in addition to any software/applications.\nTraining shall be on-site for one day.\nContract shall include training for the technical professionals (Biomedical Equipment Support Specialists)\nTraining shall cover the maintenance, troubleshooting, and repair of the system.\nTraining shall be on-site for one day.\nContractor Requirements\nAll Contractor personnel performing installation services of the equipment shall have factory training and experience in the implementation of the equipment.\nContractor shall provide copies of training certificates for the Contractor personnel performing work on-site upon the request of the Government.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall perform any available system updates during the warranty period at the discretion of Biomedical Engineering.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided.\nOn-Site Procedures\nContractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department.\nContractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information.\nContractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure.\nContractor personnel shall sign out upon completion of visit.\nPrior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking. It is the responsibility of the Contractor to park in the appropriate desig nated park ing areas.\nSafety and Security\nContractor shall follow all Occupational Safety and Health Administration (OSHA) laws and regulations. The Contractor is responsible for reporting any hazards they come across to their point of contact.\nContractor shall follow all local procedures concerning infection control. Should the Contractor be unsure of the requirements, the COR can provide the specific information and procedures.\nContractor personnel shall wear visible identification at all times while on VA property. Contract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials.\nProperty Damage\nThe contractor shall take all necessary precautions to prevent damage to any Government property.\nThe contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken.\nAny damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the Government, upon approval of the Contracting Officer.\n\nQUALITY ASSURANCE\nEnd-users, Biomedical Engineering, and/or the contract COR shall perform system verification tests to ensure the system is fully functional.\nIssues with the quality of the Contractor s work will be communicated through the Contracting Officer to the Contractor point of contact for resolution.\nDocumentation with be completed in the Government systems.\n\nEVALUATION FACTORS\nLAPAROSCOPIC SYSTEM - BECKLEY VA MEDICAL CENTER\nVolume I - Technical Capability\nThe offeror shall provide technical information regarding its proposed laparoscopic system solution as described in the Statement of Work with technical information required to include the following:\nAbility to provide all of the required components of the laparoscopic system, clearly noting any deviations from the items, dimensions, features, etc. for any parts\nDemonstrate the camera system visualization quality\nDemonstrate the ability for visualizing perfusion during open surgery\nProvide information on the surgical monitor size and quality\nExplain the fluorescence imaging capabilities and quality\nProvide information on the insufflator s features\nConfirm ability to connect to existing Steris video integration system\nProvide the Instructions for Use (IFU) or Cleaning Instructions for reprocessed/reused parts\n\nVolume II Price\nPrice - The offeror shall complete the pricing schedule provided in the above: Price/Cost Schedule.\nVolume III Past Performance\nThe offeror shall submit three (3) past performance references that are recent and relevant which focuses on experience within the last five (5) years in hospital settings that are comparable in size as the Beckley VA Medical Center. References shall include the contract number for the project, a brief description, and a point of contact to include an email address. The information shall be provided in 5 pages or less.\nPast Performance- Acceptable or Unacceptable Rating\nThe Government shall make an objective assessment of the Offeror's current/past performance. It will conduct a performance acceptable assessment based on aspects of offeror's past performance that are recent and relevant which focuses on experience within the last 5 years in the hospital settings that are comparable in size as VA Capitol Health Care Network (VISN 5) or larger which contain Operating Rooms, PACUs and other critical care areas. They have to be relevant, similar in complexity, and magnitude requirements of solicitation. Performance that are not recent, relevant, similar in complexity or magnitude will be evaluated with unacceptable performance in this area.\nVolume IV Must Complete the Trade Agreement Certificate.\nMust complete the Trade Agreement Certificate to provide the country of origin (COO) for all the line-items.\nVolume V Must provide an OEM Authorized Distributor Letter from the manufacturer\nMust provide the OEM from the manufacturer, if no OEM letter from the manufacturer is supplied. The vendor will be considered non-responsive, and the vendor will be dis-qualified at the time request for Information (RFI) will close.\n\nLINE-ITEM DESCRIPTION\n\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC\n\nBRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK\nB.1 PRICE/COST SCHEDULE\nITEM INFORMATION\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\n\nQUANTITY\n\nUNIT\n\nUNIT PRICE\n\nAMOUNT\n0001\n\n3.00\nEA\n\nPKG 1788 Camera Control Unit CCU CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788010000 LOCAL STOCK NUMBER: 1788010000\n\n0002\n\n3.00\nEA\n\nPKG L12 LED LIGHT SOURCE WITH AIM CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 220240300 LOCAL STOCK NUMBER: 220240300\n\n0003\n\n1.00\nEA\n\nFLAT PANEL ROLL STAND KIT CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0240099110K\n\nLOCAL STOCK NUMBER: 0240099110K\n0004\n3.00\nEA\n\nConnected OR Hub Base System with Device Control and SDP1000 Printer\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240200412 LOCAL STOCK NUMBER: 240200412\n\n0005\n3.00\nEA\n\nPkg SYNK 4K Wireless Transmitter CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031065 LOCAL STOCK NUMBER: 240031065\n\n0006\n3.00\nEA\n\nPkg SYNK 4K Wireless Receiver CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031075 LOCAL STOCK NUMBER: 240031075\n\n0007\n6.00\nEA\n\n32IN 4K OLED Surgical Display with OLED Display Cover Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031311 LOCAL STOCK NUMBER: 240031311\n\n0008\n10.00\nEA\n\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788610122 LOCAL STOCK NUMBER: 1788610122\n\n0009\n10.00\nEA\n\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233050400 LOCAL STOCK NUMBER: 233050400\n\n0010\n6.00\nEA\n\nPRECISION IDEAL EYES 10MM 0? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-010 LOCAL STOCK NUMBER: 0502-103-010\n0011\n6.00\nEA\n\nPRECISION IDEAL EYES 10MM 30? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-030 LOCAL STOCK NUMBER: 0502-103-030\n\n0012\n6.00\nEA\n\nPRECISION IDEAL EYES 5.5 0? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-503-010 LOCAL STOCK NUMBER: 0502-503-010\n\n0013\n6.00\nEA\n\nPRECISION IDEAL EYE 5.5 30? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments,\nEquipment, and Supplies\n\nMANUFACTURER PART NUMBER (MPN): 0502-503-030 LOCAL STOCK NUMBER: 0502-503-030\n0014\n3.00\nEA\n\nConnected OR Cart 120 V CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240-099-155 LOCAL STOCK NUMBER: 240-099-155\n\n0015\n3.00\nEA\n\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 620050001 LOCAL STOCK NUMBER: 620050001\n\n0016\n8.00\nEA\n\nPRECISION IE 4K EYPC ASC ATCL4X30?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-030 LOCAL STOCK NUMBER: 0502-444-030\n\n0017\n3.00\nEA\n\nPRECISION IE 4K EYPC ASC ATCL4X70?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-070 LOCAL STOCK NUMBER: 0502-444-070\n\n0018\n1.00\nEA\n\nHD 2.7MMX30A ARTHROSCOPE SPEEDLOCK A/C CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-127-030 LOCAL STOCK NUMBER: 0502-127-030\n\n0019\n11.00\nEA\n\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031530 LOCAL STOCK NUMBER: 747031530\n\n0020\n11.00\nEA\n\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\n\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031510 LOCAL STOCK NUMBER: 747031510\n0021\n1.00\nEA\n\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-430 LOCAL STOCK NUMBER: 0343-331-430\n\n0022\n1.00\nEA\n\nPKG. OBTURATOR 4.0MM PENCIL TIP CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-410 LOCAL STOCK NUMBER: 0343-331-410\n\n0023\n3.00\nEA\n\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0A, 180mm A CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-655-010\n\nLOCAL STOCK NUMBER: 0502-655-010\n0024\n3.00\nEA\n\nPRECISION S 4K SINUSCOPE, ACLV,4X45,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-045 LOCAL STOCK NUMBER: 0502-654-045\n\n0025\n3.00\nEA\n\nPRECISION S 4K SINUSCOPE, ACLV,4X70?,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-070 LOCAL STOCK NUMBER: 0502-654-070\n\n0026\n3.00\nEA\n\n0502652010 Sinuscope and 0502752010 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652010K LOCAL STOCK NUMBER: 0502652010K\n\n0027\n3.00\nEA\n\n0502652030 Sinuscope and 0502752030 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652030K LOCAL STOCK NUMBER: 0502652030K\n0028\n10.00\nEA\n\nENDOSCOPE AND CAMERA STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032105 LOCAL STOCK NUMBER: 233032105\n\n0029\n10.00\nEA\n\nPKG LAPAROSCOPE STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032108 LOCAL STOCK NUMBER: 233032108\n\n0030\n12.00\nEA\n\nENDOSCOPE AND HARDWARE SET TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\n\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032116 LOCAL STOCK NUMBER: 233032116\n\nGRAND TOTAL","html":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\n LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC \n\n  BRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK \n\n OEM DISTRIBUTOR/ AUTHORIZATION LETTER FROM THE MANUFACTURER IS REQUIRED FOR ALL RESPONSES, IF NO OEM LETTER IS SUPPLIED THE VENDOR WILL BE CONSIDERED NON-RESPONSIVE AND THE VENDOR WILL BE DIS-QUALIFIED AT THE TIME RFI WILL CLOSE .\n\n MUST FULLY COMPLETE FAR 52.225-6   TRADE AGREEMENT CERTIFICATE  \n\nNOTICE: \n System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications  Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM. \n\nThis is a requirement for: \n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION: \n\nThe Beckley VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBeckley VA Medical Center\nWAREHOUSE/ATTN: \n200 Veterans Avenue\nBeckley, WV 25801\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government. \nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey. \nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded. \n** MUST ANSWER ALL THE FOLLOWING QUESTIONS ** \n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above? \n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly \n\n    (1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n          (2) __ Outside the United States.\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\n Legal Business/Company Name (as it is indicated in https://sam.gov ).\n\n Unique Entity ID UEI (SAM).\n\n Warranty Information (Can be a separate attachment).\n\n Point of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO. \n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase. \nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award. \n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov.  No Telephone responses shall not be accepted. Responses must be received no later than Friday, May 23, 2025, by 3:00 PM (EST). \n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\n\nSTATEMENT OF WORK (SOW)\nLAPAROSCOPIC SYSTEM FOR BECKLEY VAMC.\n\nGENERAL:\nScope of Services:\nThe purpose of this requirement is to replace the failing laparoscopic towers for the Operating Rooms at the Beckley VA Medical Center. The requirement includes the cameras, controllers, carts, light sources, device controllers, transmitters, receivers, displays, insufflators, printers, and more for the three systems. The procurement shall include all parts, materials, labor, software/licenses, and travel to complete the full installation/configuration of the systems.\nLocation: 200 Veterans Ave, Beckley, WV 25801\nPerformance Period: Requested delivery within 90 days of award\nWORK HOURS:\nHours of Operation: Normal business hours are Monday through Friday, 8:00 a.m.  4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR).\nDelivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 8:00 a.m. to 4:00 p.m., excluding holidays.\nNational Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.\n\nSPECIFICATIONS: \nTechnical Requirements\nThe procurement is for a brand name or equal solution for three comprehensive surgical video tower systems to be utilized during laparoscopic, sinuscopic, and arthroscopic cases.\nThe Stryker brand name components include:\nDescription/Part Number*\nQty\n1788010000\nPKG 1788 Camera Control Unit CCU\n3\n220240300\nPKG L12 LED LIGHT SOURCE WITH AIM\n3\n0240099110K\nFLAT PANEL ROLL STAND KIT\n1\n240200412\nConnected OR Hub Base System with Device Control and SDP1000 Printer\n3\n240031065\nPkg SYNK 4K Wireless Transmitter\n3\n240031075\nPkg SYNK 4K Wireless Receiver\n3\n240031311\n32IN 4K OLED Surgical Display with OLED Display Cover Kit\n6\n1788610122\nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER\n10\n233050400\nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\n10\n0502-103-010\nPRECISION IDEAL EYES 10MM 0Â° HD AC LPSC\n6\n0502-103-030\nPRECISION IDEAL EYES 10MM 30Â° HD AC LPSC\n6\n0502-503-010\nPRECISION IDEAL EYES 5.5 0Â° HD ACL LAP30\n6\n0502-503-030\nPRECISION IDEAL EYE 5.5 30Â° HD ACL LAP30\n6\n240-099-155\nConnected OR Cart 120 V\n3\n620050001\nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS\n3\n0502-444-030\nPRECISION IE 4K EYPC ASC ATCL4X30Â°140SLK\n8\n0502-444-070\nPRECISION IE 4K EYPC ASC ATCL4X70Â°140SLK\n3\n0502-127-030\nHD 2.7MMX30Ã‚Â° ARTHROSCOPE SPEEDLOCK A/C\n1\n747031530\nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST\n11\n747031510\nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA\n11\n0343-331-430\nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES\n1\n0343-331-410\nPKG. OBTURATOR 4.0MM PENCIL TIP\n1\n0502-655-010\nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0Ã‚Â°, 180mm Ã‚Â \n3\n0502-654-045\nPRECISION S 4K SINUSCOPE, ACLV,4X45Â°,155\n3\n0502-654-070\nPRECISION S 4K SINUSCOPE, ACLV,4X70Â°,155\n3\n0502652010K\n0502652010 Sinuscope and 0502752010 Sheath Kit\n3\n0502652030K\n0502652030 Sinuscope and 0502752030 Sheath Kit\n3\n233032105\nENDOSCOPE AND CAMERA STERILIZATION TRAY\n10\n233032108\nPKG LAPAROSCOPE STERILIZATION TRAY\n10\n233032116\nENDOSCOPE AND HARDWARE SET TRAY\n12\n\nThe systems shall be able to perform the video visualization function for all laparoscopic, sinuscopic, and arthroscopic cases at the Beckley VAMC.\nThe three systems shall be on towers/carts to allow for mobility in the operating room.\nThe system shall have advanced visualization/quality.\nThe system shall have the ability for visualizing perfusion during open surgery.\nThe systems shall include 2, 32inch, 4K, OLED displays. One located on the scope tower and the other to be located on an existing equipment boom.\nThe systems  insufflators are preferred to have integrated heating, humidification, and smoke evacuation.\nThe system shall offer a means to export captured images off the device to be later scanned and manually uploaded into the VA EMR. \nThe provided boom mounted monitors shall be able to connect to the existing Steris video integration system for displaying video/images in the ORs via a hardwired connection (i.e. HDMI).\nContractor shall provide two copies of the operating and service manuals.\nScope Requirements\n\nLaparoscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n10\n330\n0\n75\nHD\nAutoclavable\n5\n10\n330\n30\n75\nHD\nAutoclavable\n5\n5\n300\n0\n75\nHD\nAutoclavable\n5\n5\n300\n30\n75\nHD\nAutoclavable\n5\n\nArthroscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nLock Type\nDefinition\nCleaning\nQuantity\n4\n140 mm\n0 deg\nSpeedlock\n4K\nAutoclavable\nÂ 8\n4\n140 mm\n70 deg\nSpeedlock\n4K\nAutoclavable\nÂ 3\n\nSinuscopes\nDiameter, mm\nWorking Length, mm\nDirection of view, degrees\nField of View, degrees\nDefinition\nCleaning\nQuantity\n4\n180\n0\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n45\n105\n4K\nAutoclavable\nÂ 3\n4\n155\n70\n105\n4K\nAutoclavable\nÂ 3\n3.1\n170\n0\n80\n4K\nAutoclavable\nÂ 3\n3.1\n170\n30\n80\n4K\nAutoclavable\nÂ 3\n\nNetworking Requirements.\nConnection to the VA network is NOT a requirement. \nIf the proposed solution requires a VA network connection to operate, the vendor will be required to complete the VA s required documentation. \nShould the manufacturer of the equipment not have an approved Enterprise Risk Analysis completed, this will be required in order to fully install the system on the network.\nOnly OEM-supported operating systems shall be provided\nFollowing purchase, the VA will provide specific network information for the configuration of the system.\nIf remote support is required, the Contractor must have a completed MOU/ISA.\nCleaning/Sterilization Requirements.\nThe Contractor shall provide cleaning/sterilization instructions (Instructions for Use   IFU) for the Government to determine the ability of the facility to properly process the equipment.\nDelivery Requirements\nDelivery is required 90 days from award of the contract.\nLarge deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place.\nContractor is to provide the COR with shipment tracking information.\nInstallation Requirements\nFull installation of the system shall be included as a part of this contract. This will include, but not be limited to: \nAssembly and configuration of scope towers\nMounting of monitors on existing equipment booms. Contractor shall provide new mounting brackets if existing bracket cannot support the new monitors. Contractor to utilize existing power present in the boom. \nAll parts, materials, tools, labor, and travel to complete the installation shall be included as a part of this contract.\nContractor is required to complete all configuration for the system to be usable.\nContractor shall provide validation that the system is fully functional upon completion of the installation/implementation.\nPatient Health Information\nThe Contractor shall safeguard patient health information.\nThe Contractor shall report to the Biomedical Engineering Department any issues with disclosed or unsecure patient health information.\nContractor shall not remove any hard-drives or storage systems containing sensitive or patient health information.\nTraining Requirements\nContract shall include training for the end-users in the operation of the system.\nTraining shall be on the function and use of the device, in addition to any software/applications.\nTraining shall be on-site for one day.\nContract shall include training for the technical professionals (Biomedical Equipment Support Specialists)\nTraining shall cover the maintenance, troubleshooting, and repair of the system.\nTraining shall be on-site for one day.\nContractor Requirements\nAll Contractor personnel performing installation services of the equipment shall have factory training and experience in the implementation of the equipment.\nContractor shall provide copies of training certificates for the Contractor personnel performing work on-site upon the request of the Government.\nWarranty Information\nThe equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment.\nWarranty support shall include repair of the system\nWarranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance.\nRequests for warranty support shall be made to the telephone support number provided by the Contractor.\nWarranty support requests shall be responded to within 2 days.\nContractor shall perform any available system updates during the warranty period at the discretion of Biomedical Engineering.\nContractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services.\nService reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided.\nOn-Site Procedures\nContractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department.\nContractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information.\nContractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure.\nContractor personnel shall sign out upon completion of visit.\nPrior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired.\nThe VA campus is non-smoking. Contractor personnel are required to comply with this policy.\nParking. It is the responsibility of the Contractor to park in the appropriate desig nated park ing areas.\nSafety and Security\nContractor shall follow all Occupational Safety and Health Administration (OSHA) laws and regulations. The Contractor is responsible for reporting any hazards they come across to their point of contact.\nContractor shall follow all local procedures concerning infection control. Should the Contractor be unsure of the requirements, the COR can provide the specific information and procedures.\nContractor personnel shall wear visible identification at all times while on VA property. Contract personnel are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials.\nProperty Damage\nThe contractor shall take all necessary precautions to prevent damage to any Government property.\nThe contractor shall report any damages immediately and shall be assessed current replacement costs for property damaged by the contractor, unless corrective action is taken.\nAny damaged material (i.e., trees, shrubs, lawn/turf, curbs, gutters, sidewalks, etc.) will be replaced in a timely manner or corrected by the contractor with like materials, at no extra cost to the Government, upon approval of the Contracting Officer.\n\nQUALITY ASSURANCE\nEnd-users, Biomedical Engineering, and/or the contract COR shall perform system verification tests to ensure the system is fully functional.\nIssues with the quality of the Contractor s work will be communicated through the Contracting Officer to the Contractor point of contact for resolution.\nDocumentation with be completed in the Government systems.\n\nEVALUATION FACTORS\nLAPAROSCOPIC SYSTEM - BECKLEY VA MEDICAL CENTER\nVolume I - Technical Capability\nThe offeror shall provide technical information regarding its proposed laparoscopic system solution as described in the Statement of Work with technical information required to include the following:\nAbility to provide all of the required components of the laparoscopic system, clearly noting any deviations from the items, dimensions, features, etc. for any parts\nDemonstrate the camera system visualization quality\nDemonstrate the ability for visualizing perfusion during open surgery\nProvide information on the surgical monitor size and quality\nExplain the fluorescence imaging capabilities and quality\nProvide information on the insufflator s features\nConfirm ability to connect to existing Steris video integration system\nProvide the Instructions for Use (IFU) or Cleaning Instructions for reprocessed/reused parts\n\nVolume II   Price\nPrice - The offeror shall complete the pricing schedule provided in the above: Price/Cost Schedule.\nVolume III   Past Performance\nThe offeror shall submit three (3) past performance references that are recent and relevant which focuses on experience within the last five (5) years in hospital settings that are comparable in size as the Beckley VA Medical Center. References shall include the contract number for the project, a brief description, and a point of contact to include an email address. The information shall be provided in 5 pages or less.\nPast Performance- Acceptable or Unacceptable Rating\nThe Government shall make an objective assessment of the Offeror's current/past performance. It will conduct a performance acceptable assessment based on aspects of offeror's past performance that are recent and relevant which focuses on experience within the last 5 years in the hospital settings that are comparable in size as VA Capitol Health Care Network (VISN 5) or larger which contain Operating Rooms, PACUs and other critical care areas. They have to be relevant, similar in complexity, and magnitude requirements of solicitation. Performance that are not recent, relevant, similar in complexity or magnitude will be evaluated with unacceptable performance in this area.\nVolume IV   Must Complete the Trade Agreement Certificate.\nMust complete the Trade Agreement Certificate to provide the country of origin (COO) for all the line-items. \nVolume V   Must provide an OEM Authorized Distributor Letter from the manufacturer\nMust provide the OEM from the manufacturer, if no OEM letter from the manufacturer is supplied. The vendor will be considered non-responsive, and the vendor will be dis-qualified at the time request for Information (RFI) will close. \n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nLINE-ITEM DESCRIPTION\n\n LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC \n\n  BRAND NAME OR EQUAL TO STRYKER IAW STATEMENT OF WORK \nB.1 PRICE/COST SCHEDULE\nITEM INFORMATION\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\n\nQUANTITY\n\nUNIT\n\nUNIT PRICE\n\nAMOUNT\n0001\n\n3.00\nEA\n  \n  \n\nPKG 1788 Camera Control Unit CCU CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788010000 LOCAL STOCK NUMBER: 1788010000\n\n0002\n\n3.00\nEA\n  \n  \n\nPKG L12 LED LIGHT SOURCE WITH AIM CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 220240300 LOCAL STOCK NUMBER: 220240300\n\n0003\n\n1.00\nEA\n  \n  \n\nFLAT PANEL ROLL STAND KIT CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0240099110K\n\n\nLOCAL STOCK NUMBER: 0240099110K\n0004\n3.00\nEA\n  \n  \nConnected OR Hub Base System with Device Control and SDP1000 Printer\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240200412 LOCAL STOCK NUMBER: 240200412\n\n0005\n3.00\nEA\n  \n  \nPkg SYNK 4K Wireless Transmitter CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031065 LOCAL STOCK NUMBER: 240031065\n\n0006\n3.00\nEA\n  \n  \nPkg SYNK 4K Wireless Receiver CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031075 LOCAL STOCK NUMBER: 240031075\n\n\n0007\n6.00\nEA\n  \n  \n32IN 4K OLED Surgical Display with OLED Display Cover Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240031311 LOCAL STOCK NUMBER: 240031311\n\n0008\n10.00\nEA\n  \n  \nPKG 1788 4K CAMERA HEAD WITH INTEGRATED COUPLER CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 1788610122 LOCAL STOCK NUMBER: 1788610122\n\n0009\n10.00\nEA\n  \n  \nFG SAFELIGHT FIBER OPTIC CABLE WITH ADVANCED IMAGING MODALITY 5 MM\nCONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233050400 LOCAL STOCK NUMBER: 233050400\n\n0010\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 10MM 0? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\n\n\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-010 LOCAL STOCK NUMBER: 0502-103-010\n0011\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 10MM 30? HD AC LPSC CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-103-030 LOCAL STOCK NUMBER: 0502-103-030\n\n0012\n6.00\nEA\n  \n  \nPRECISION IDEAL EYES 5.5 0? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-503-010 LOCAL STOCK NUMBER: 0502-503-010\n\n0013\n6.00\nEA\n  \n  \nPRECISION IDEAL EYE 5.5 30? HD ACL LAP30 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments,\nEquipment, and Supplies\n\n\nMANUFACTURER PART NUMBER (MPN): 0502-503-030 LOCAL STOCK NUMBER: 0502-503-030\n0014\n3.00\nEA\n  \n  \nConnected OR Cart 120 V CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 240-099-155 LOCAL STOCK NUMBER: 240-099-155\n\n0015\n3.00\nEA\n  \n  \nPNEUMOCLEAR CO2 CONDITIONING INSUFFLATOR KIT BOTTLE GAS CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 620050001 LOCAL STOCK NUMBER: 620050001\n\n0016\n8.00\nEA\n  \n  \nPRECISION IE 4K EYPC ASC ATCL4X30?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-030 LOCAL STOCK NUMBER: 0502-444-030\n\n\n0017\n3.00\nEA\n  \n  \nPRECISION IE 4K EYPC ASC ATCL4X70?140SLK CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-444-070 LOCAL STOCK NUMBER: 0502-444-070\n\n0018\n1.00\nEA\n  \n  \nHD 2.7MMX30A ARTHROSCOPE SPEEDLOCK A/C CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-127-030 LOCAL STOCK NUMBER: 0502-127-030\n\n0019\n11.00\nEA\n  \n  \nPKG. PUMP CANNULA 5.8MM W 1 ROTATING ST CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031530 LOCAL STOCK NUMBER: 747031530\n\n0020\n11.00\nEA\n  \n  \nPKG. PENCIL OBTURATOR 5.8MM PUMP CANNULA CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\n\n\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 747031510 LOCAL STOCK NUMBER: 747031510\n0021\n1.00\nEA\n  \n  \nPKG. 4.0MM SINGLE ROTATING STOPCOCK - WITH HOLES CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-430 LOCAL STOCK NUMBER: 0343-331-430\n\n0022\n1.00\nEA\n  \n  \nPKG. OBTURATOR 4.0MM PENCIL TIP CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0343-331-410 LOCAL STOCK NUMBER: 0343-331-410\n\n0023\n3.00\nEA\n  \n  \nPrecision S 4K Sinuscope, Autoclavable, 4mm x 0A, 180mm A CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-655-010\n\n\nLOCAL STOCK NUMBER: 0502-655-010\n0024\n3.00\nEA\n  \n  \nPRECISION S 4K SINUSCOPE, ACLV,4X45,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-045 LOCAL STOCK NUMBER: 0502-654-045\n\n0025\n3.00\nEA\n  \n  \nPRECISION S 4K SINUSCOPE, ACLV,4X70?,155 CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502-654-070 LOCAL STOCK NUMBER: 0502-654-070\n\n0026\n3.00\nEA\n  \n  \n0502652010 Sinuscope and 0502752010 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652010K LOCAL STOCK NUMBER: 0502652010K\n\n0027\n3.00\nEA\n  \n  \n\n0502652030 Sinuscope and 0502752030 Sheath Kit CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 0502652030K LOCAL STOCK NUMBER: 0502652030K\n0028\n10.00\nEA\n  \n  \nENDOSCOPE AND CAMERA STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032105 LOCAL STOCK NUMBER: 233032105\n\n0029\n10.00\nEA\n  \n  \nPKG LAPAROSCOPE STERILIZATION TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032108 LOCAL STOCK NUMBER: 233032108\n\n0030\n12.00\nEA\n  \n  \nENDOSCOPE AND HARDWARE SET TRAY CONTRACT TYPE: FIRM-FIXED PRICE\n\"BRAND NAME OR EQUAL TO STRYKER IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\n\n\n\nPRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies\nMANUFACTURER PART NUMBER (MPN): 233032116 LOCAL STOCK NUMBER: 233032116\n\nGRAND TOTAL","origin":"detail"},"contacts":[{"name":"Mohsin Abbas","role":"primary","email":"Mohsin.Abbas2@va.gov","title":"Contract Specialist"}],"place_of_performance":{"street":"Beckley VA Medical Center Beckley, WV 25801"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"99ec978104d144588480602dffd21106","name":"36C24525Q0522.docx","kind":"file","mime_type":".docx","size_bytes":79666,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/99ec978104d144588480602dffd21106/download","mirrored":false},{"resource_id":"1480c4477ac14a9bafbeab0a619c6bce","name":"S02 - ATTACHMENT 1 - LINE-ITEM DESCRIPTION - LAPAROSCOPE SYSTEM - BRAND NAME OR EQUAL TO STYRYER - 05-14-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":102150,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1480c4477ac14a9bafbeab0a619c6bce/download","mirrored":false},{"resource_id":"12439e6b090f41babb2e32177b9b4e54","name":"S02 - ATTACHMENT 2 - STATEMENT OF WORK - LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC - BRAND NAME OR EQUAL TO STRYKER - 05-14-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":239050,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/12439e6b090f41babb2e32177b9b4e54/download","mirrored":false},{"resource_id":"c7e5ce52d3a6454283d97a8b9b066bd9","name":"S02 - ATTACHMENT 3 - EVALUATION FACTORS - LAPAROSCOPIC SYSTEM FOR BECKLEY VAMC - 05-14-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":140277,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c7e5ce52d3a6454283d97a8b9b066bd9/download","mirrored":false},{"resource_id":"9248a151fd7b4a15ac7b4fa8c724bb8f","name":"S02 - ATTACHMENT 4 - FAR 52.225-6 - TRADE AGREEMENTS CERTIFICATE - 05-14-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":83708,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9248a151fd7b4a15ac7b4fa8c724bb8f/download","mirrored":false},{"resource_id":"ffbc661200544a0aa44900dd0489b07b","name":"S02 - ATTACHMENT 5 - VAAR 852.212-71 - GRAY AND COUNTERFEITS ITEMS - Gray Market Prevention Language - 05-14-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":80558,"posted_at":"2025-05-14T12:49:21.259Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ffbc661200544a0aa44900dd0489b07b/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}