{"canonical":"https://sealedbidder.com/opportunities/36c24525q0382","key":"36C24525Q0382","url":"https://sealedbidder.com/opportunities/36c24525q0382","title":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","solicitation_number":"36C24525Q0382","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-24T16:00:00Z","first_posted":"2025-03-14","last_posted":"2025-03-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"811310","psc":"J065","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"072f7b820d0945b4b08acbef2c45590d","title":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","solicitation_number":"36C24525Q0382","notice_type":"r","base_type":"r","posted":"2025-03-14","posted_at":"2025-03-14T16:33:44.714Z","due_at":"2025-03-24T16:00:00Z","due_date":"2025-03-24","cancelled":false,"archived":true,"archive_date":"2025-04-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/072f7b820d0945b4b08acbef2c45590d/view","enriched":true,"history":[{"index":3,"title":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T16:33:44.714Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"072f7b820d0945b4b08acbef2c45590d","solicitation_number":"36C24525Q0382"}]}],"latest_notice_id":"072f7b820d0945b4b08acbef2c45590d","first_type":"r","notices":[{"dates":{"posted":"2025-03-14","posted_at":"2025-03-14T16:33:44.714Z","created_at":"2025-03-14T16:28:30.226Z","modified_at":"2025-04-09T03:55:48.026Z","response_deadline":{"raw":"2025-03-24T12:00:00-04:00","utc":"2025-03-24T16:00:00Z","date":"2025-03-24","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/072f7b820d0945b4b08acbef2c45590d/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-08","archive_type":"auto15"},"history":[{"index":3,"title":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T16:33:44.714Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"072f7b820d0945b4b08acbef2c45590d","solicitation_number":"36C24525Q0382"}],"contacts":[{"name":"Kenneth Dougherty","role":"primary","email":"kenneth.dougherty@va.gov"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"072f7b820d0945b4b08acbef2c45590d","lineage_id":"072f7b820d0945b4b08acbef2c45590d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T09:04:05.774097233Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d64247ea1d9808637dd74204ed9fceddd8661cb99fb677be352cb9fef06f4497","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T09:04:05.774097233Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>DISCLAIMER</strong></p>\n\n<p>The sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned.</p>\n\n<p>All capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents.</p>\n\n<p>GENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following:</p>\n\n<p>a. Company Name</p>\n\n<p>b. SAM Unique Entity ID &amp; cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/</p>\n\n<p>c. Company Address</p>\n\n<p>d. Point of contact(s) name</p>\n\n<p>e. Telephone number(s)</p>\n\n<p>f. Email address(s)</p>\n\n<p>g. Socioeconomic data</p>\n\n<p>h. Company Business Size Status and representations of your business</p>\n\n<p>i. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work</p>\n\n<p>This is not a request for quotes. The estimated period of performance is September 2025 through August 2026. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted.</p>\n\n<p></p>\n\n<p></p>\n\n<p>STATEMENT OF WORK</p>\n\n<ul>\n\t<li>4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing.</li>\n\t<li>As needed emergency service calls with 12 hour response time.</li>\n\t<li>PM Inspection Checklist-</li>\n</ul>\n\n<ul>\n\t<li>Visually check the outside for signs of leaks or damage</li>\n\t<li>Check steam, water and air supply lines for leaks</li>\n\t<li>Check the door travel operation</li>\n\t<li>Check and adjust door for 1/8&quot; clearance</li>\n\t<li>Check the lower door switch operation</li>\n\t<li>Check the door lock cylinder operation</li>\n\t<li>Check the power door cylinder operation (if automatic)</li>\n\t<li>Check for proper door seal retraction</li>\n\t<li>Check the inside of the chamber for melted materials and clean</li>\n\t<li>Pull and clean the drain strainer</li>\n\t<li>Clean and check the chamber screen</li>\n\t<li>Check the door gasket and replace if necessary</li>\n\t<li>Check the traps, valves, solenoid and the plumbing for leaks</li>\n\t<li>Check load cart or shelf rack for proper alignment</li>\n\t<li>Check the airlines and valves for leaks</li>\n\t<li>Check liquid cycle</li>\n\t<li>Check the slow exhaust rate</li>\n\t<li>Check the operation of the vacuum system</li>\n\t<li>Check the 2 PSI pressure AND operation</li>\n\t<li>Run solid cycle @ 121&ordm;C</li>\n\t<li>Run bio bag cycle @ 121&ordm;C</li>\n\t<li>a.) Check the prevac depth</li>\n\t<li>b.) Check the charge pressure</li>\n\t<li>Check &quot;water in chamber&quot; safety sensor operation</li>\n\t<li>Check the dry cycle phase for proper operation</li>\n\t<li>Perform a leak test (annually)</li>\n\t<li>Replace air-in filter annually (indicate date changed)</li>\n\t<li>Check tempering valve for proper effluent quench</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201.</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>All parts included except pumps/motors/controls</li>\n</ul>\n\n<p></p>\n\n<p>Location(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201</p>\n\n<p></p>\n\n<p>End</p>","text":"DISCLAIMER\n\nThe sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned.\n\nAll capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents.\n\nGENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following:\n\na. Company Name\n\nb. SAM Unique Entity ID & cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/\n\nc. Company Address\n\nd. Point of contact(s) name\n\ne. Telephone number(s)\n\nf. Email address(s)\n\ng. Socioeconomic data\n\nh. Company Business Size Status and representations of your business\n\ni. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work\n\nThis is not a request for quotes. The estimated period of performance is September 2025 through August 2026. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted.\n\nSTATEMENT OF WORK\n\n• 4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing.\n\n• As needed emergency service calls with 12 hour response time.\n\n• PM Inspection Checklist-\n\n• Visually check the outside for signs of leaks or damage\n\n• Check steam, water and air supply lines for leaks\n\n• Check the door travel operation\n\n• Check and adjust door for 1/8\" clearance\n\n• Check the lower door switch operation\n\n• Check the door lock cylinder operation\n\n• Check the power door cylinder operation (if automatic)\n\n• Check for proper door seal retraction\n\n• Check the inside of the chamber for melted materials and clean\n\n• Pull and clean the drain strainer\n\n• Clean and check the chamber screen\n\n• Check the door gasket and replace if necessary\n\n• Check the traps, valves, solenoid and the plumbing for leaks\n\n• Check load cart or shelf rack for proper alignment\n\n• Check the airlines and valves for leaks\n\n• Check liquid cycle\n\n• Check the slow exhaust rate\n\n• Check the operation of the vacuum system\n\n• Check the 2 PSI pressure AND operation\n\n• Run solid cycle @ 121ºC\n\n• Run bio bag cycle @ 121ºC\n\n• a.) Check the prevac depth\n\n• b.) Check the charge pressure\n\n• Check \"water in chamber\" safety sensor operation\n\n• Check the dry cycle phase for proper operation\n\n• Perform a leak test (annually)\n\n• Replace air-in filter annually (indicate date changed)\n\n• Check tempering valve for proper effluent quench\n\n• The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201.\n\n• All parts included except pumps/motors/controls\n\nLocation(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201\n\nEnd","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0382","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J065"}],"due_at":"2025-03-24T16:00:00Z","due_date":"2025-03-24","closes_at":"2025-03-24T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T09:54:53.132167Z","principal_notice_id":"072f7b820d0945b4b08acbef2c45590d","description":{"text":"DISCLAIMER\n\nThe sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned.\n\nAll capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents.\n\nGENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following:\n\na. Company Name\n\nb. SAM Unique Entity ID & cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/\n\nc. Company Address\n\nd. Point of contact(s) name\n\ne. Telephone number(s)\n\nf. Email address(s)\n\ng. Socioeconomic data\n\nh. Company Business Size Status and representations of your business\n\ni. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work\n\nThis is not a request for quotes. The estimated period of performance is September 2025 through August 2026. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted.\n\nSTATEMENT OF WORK\n\n• 4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing.\n\n• As needed emergency service calls with 12 hour response time.\n\n• PM Inspection Checklist-\n\n• Visually check the outside for signs of leaks or damage\n\n• Check steam, water and air supply lines for leaks\n\n• Check the door travel operation\n\n• Check and adjust door for 1/8\" clearance\n\n• Check the lower door switch operation\n\n• Check the door lock cylinder operation\n\n• Check the power door cylinder operation (if automatic)\n\n• Check for proper door seal retraction\n\n• Check the inside of the chamber for melted materials and clean\n\n• Pull and clean the drain strainer\n\n• Clean and check the chamber screen\n\n• Check the door gasket and replace if necessary\n\n• Check the traps, valves, solenoid and the plumbing for leaks\n\n• Check load cart or shelf rack for proper alignment\n\n• Check the airlines and valves for leaks\n\n• Check liquid cycle\n\n• Check the slow exhaust rate\n\n• Check the operation of the vacuum system\n\n• Check the 2 PSI pressure AND operation\n\n• Run solid cycle @ 121ºC\n\n• Run bio bag cycle @ 121ºC\n\n• a.) Check the prevac depth\n\n• b.) Check the charge pressure\n\n• Check \"water in chamber\" safety sensor operation\n\n• Check the dry cycle phase for proper operation\n\n• Perform a leak test (annually)\n\n• Replace air-in filter annually (indicate date changed)\n\n• Check tempering valve for proper effluent quench\n\n• The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201.\n\n• All parts included except pumps/motors/controls\n\nLocation(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201\n\nEnd","html":"<p><strong>DISCLAIMER</strong></p>\n\n<p>The sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned.</p>\n\n<p>All capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents.</p>\n\n<p>GENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following:</p>\n\n<p>a. Company Name</p>\n\n<p>b. SAM Unique Entity ID &amp; cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/</p>\n\n<p>c. Company Address</p>\n\n<p>d. Point of contact(s) name</p>\n\n<p>e. Telephone number(s)</p>\n\n<p>f. Email address(s)</p>\n\n<p>g. Socioeconomic data</p>\n\n<p>h. Company Business Size Status and representations of your business</p>\n\n<p>i. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work</p>\n\n<p>This is not a request for quotes. The estimated period of performance is September 2025 through August 2026. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted.</p>\n\n<p></p>\n\n<p></p>\n\n<p>STATEMENT OF WORK</p>\n\n<ul>\n\t<li>4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing.</li>\n\t<li>As needed emergency service calls with 12 hour response time.</li>\n\t<li>PM Inspection Checklist-</li>\n</ul>\n\n<ul>\n\t<li>Visually check the outside for signs of leaks or damage</li>\n\t<li>Check steam, water and air supply lines for leaks</li>\n\t<li>Check the door travel operation</li>\n\t<li>Check and adjust door for 1/8&quot; clearance</li>\n\t<li>Check the lower door switch operation</li>\n\t<li>Check the door lock cylinder operation</li>\n\t<li>Check the power door cylinder operation (if automatic)</li>\n\t<li>Check for proper door seal retraction</li>\n\t<li>Check the inside of the chamber for melted materials and clean</li>\n\t<li>Pull and clean the drain strainer</li>\n\t<li>Clean and check the chamber screen</li>\n\t<li>Check the door gasket and replace if necessary</li>\n\t<li>Check the traps, valves, solenoid and the plumbing for leaks</li>\n\t<li>Check load cart or shelf rack for proper alignment</li>\n\t<li>Check the airlines and valves for leaks</li>\n\t<li>Check liquid cycle</li>\n\t<li>Check the slow exhaust rate</li>\n\t<li>Check the operation of the vacuum system</li>\n\t<li>Check the 2 PSI pressure AND operation</li>\n\t<li>Run solid cycle @ 121&ordm;C</li>\n\t<li>Run bio bag cycle @ 121&ordm;C</li>\n\t<li>a.) Check the prevac depth</li>\n\t<li>b.) Check the charge pressure</li>\n\t<li>Check &quot;water in chamber&quot; safety sensor operation</li>\n\t<li>Check the dry cycle phase for proper operation</li>\n\t<li>Perform a leak test (annually)</li>\n\t<li>Replace air-in filter annually (indicate date changed)</li>\n\t<li>Check tempering valve for proper effluent quench</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201.</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>All parts included except pumps/motors/controls</li>\n</ul>\n\n<p></p>\n\n<p>Location(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201</p>\n\n<p></p>\n\n<p>End</p>","origin":"detail"},"contacts":[{"name":"Kenneth Dougherty","role":"primary","email":"kenneth.dougherty@va.gov"}],"place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["811310"],"award":null,"attachments":[{"resource_id":"30706322508e4dd8ba0ecf66e37bb6df","name":"36C24525Q0382.docx","kind":"file","mime_type":".docx","size_bytes":17855,"posted_at":"2025-03-14T16:33:44.714Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/30706322508e4dd8ba0ecf66e37bb6df/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"N0042126Q1350","latest_notice_id":"644226ad25d54fcaae8fd3c05d48f073","title":"Colibrium GEM2 Maintenance","solicitation_number":"N0042126Q1350","notice_type":"k","first_type":"k","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2027-09-18T16:00:00Z","due_date":"2027-09-18","closes_at":"2027-09-18T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00421","office_name":"NAVAL AIR WARFARE CENTER AIR DIV","naics":"811310","psc":"J036","set_aside":null,"state":"MD","county":"24037","county_name":"St. Mary's County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N3225327Q0011","latest_notice_id":"e4f2bdc21bab431d8dddd03dc4c01ccf","title":"Dry Dock Flow Meter Service","solicitation_number":"N32253-27-Q-0011","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N32253","office_name":"PEARL HARBOR NAVAL SHIPYARD IMF","naics":"811310","psc":"J049","set_aside":null,"state":"HI","county":"15003","county_name":"Honolulu County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":58,"indexable":false}