{"canonical":"https://sealedbidder.com/opportunities/36c24525q0340","key":"36C24525Q0340","url":"https://sealedbidder.com/opportunities/36c24525q0340","title":"6515--Dialysis Unit Replacement","solicitation_number":"36C24525Q0340","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-07T17:00:00Z","first_posted":"2025-02-26","last_posted":"2025-02-26","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"6515","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"370ea5592d234cb19e69a3efbdd1e405","title":"6515--Dialysis Unit Replacement","solicitation_number":"36C24525Q0340","notice_type":"r","base_type":"r","posted":"2025-02-26","posted_at":"2025-02-26T22:16:24.249Z","due_at":"2025-03-07T17:00:00Z","due_date":"2025-03-07","cancelled":false,"archived":true,"archive_date":"2025-03-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/370ea5592d234cb19e69a3efbdd1e405/view","enriched":true,"history":[{"index":3,"title":"6515--Dialysis Unit Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-26T22:16:24.249Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"370ea5592d234cb19e69a3efbdd1e405","solicitation_number":"36C24525Q0340"}]}],"latest_notice_id":"370ea5592d234cb19e69a3efbdd1e405","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-26","posted_at":"2025-02-26T22:16:24.249Z","created_at":"2025-02-26T22:16:22.059Z","modified_at":"2025-03-23T04:00:05.047Z","response_deadline":{"raw":"2025-03-07T12:00:00-05:00","utc":"2025-03-07T17:00:00Z","date":"2025-03-07","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/370ea5592d234cb19e69a3efbdd1e405/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Dialysis Unit Replacement","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-22","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Dialysis Unit Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-26T22:16:24.249Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"370ea5592d234cb19e69a3efbdd1e405","solicitation_number":"36C24525Q0340"}],"contacts":[{"name":"Joseph J. Krupa","role":"primary","email":"joseph.krupa@va.gov","phone":"(304) 263-0811 ext.7618","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"370ea5592d234cb19e69a3efbdd1e405","lineage_id":"370ea5592d234cb19e69a3efbdd1e405","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T12:55:05.782402006Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"2fb8d4e520998155064683f7733825aaa621f21a45737a4a69bf48f1ab1912b5","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T12:55:05.782402006Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The VA Medical Center is conducting this Sources Sought to identify contractors who possess capabilities to provide the product described in the specification below.  \nAs permitted by the FAR Part 10, this is a market research tool being utilized for the informational and planning purposes.  Your responses will assist the Government in the development of its acquisition strategy.  \nResponse is strictly voluntary   it is not mandatory to submit a response to this notice to participate in formal RFQ process that may take place in the future.  However, it should be noted that information gathered through this notice may significantly influence our acquisition strategy. All interested parties will be required to respond separately to any solicitation posted because of this sources sought notice. \nRespondents will not be notified of the results of the evaluation.  We appreciate your interest and thank you in advance for responding to the sources sought. \nThis service will be implemented using the North American Industry Classification System (NAICS) Code 339112.   \nRespondents who are supply information from a GSA contract please provide your contract number and category number in your response.\n  NOTES\nAll Capability Statements/Responses to this Sources Sought Notice shall be submitted via email only to joseph.krupa@va.gov. Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted. Responses to this Sources Sought Notice must be received no later than March 7, 2025, at 12:00 p.m. (Eastern Standard Time). This Sources Sought Notice may or may not assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced later, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought Notice.\n\nDISCLAIMER\nThis RFI is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.\n\n\n\n\nStatement of Work\nAK98 Hemodialysis Machine\nVA Maryland Health Care System\nBaltimore, MD\n11/18/2024\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure six AK98 Hemodialysis\nMachines with six accessory shelf extension kits for WRO. These machines are utilized for dialysis treatments capable of both sodium and bicarbonate profiling for continued care of veteran patients at the Baltimore VA Medical Center. The current dialysis machines utilized for kidney care at the VAMHCS are being recalled for overheating and burnt power sources. If these replacements are not purchased, these dialysis units will soon no longer be able to be utilized at the VAMHCS and veterans will have to travel to another facility for proper care. These new hemodialysis machines provide a higher URF for more efficient dialysis use and decrease the number of treatments for improved patient experience. Each AK98 Hemodialysis Machine will include an accessory shelf extension for portable RO transport with the machine to save space and increase mobility. The primary function of these hemodialysis machines are to treat kidney failure by filtering out toxins and purifying the blood in the body. Key criteria include system size, push-pull capability, battery life, range of therapy options, and system weight. \n\n\nSCOPE: \nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted. \nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope. \nThe contractor shall deliver the system to the Baltimore VA Medical center. \nThe assembly and validation of the system must be performed by a vendor service trained representative. \nThe contractor is responsible for identifying any missing parts or components not included in the order for the dialysis units to be successfully installed and validated to their full potential. \nThe contractor shall include accessories and consumables that have been detailed on the provided quotes. \nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to or exceed the Baxter AK98 Hemodialysis Machine + Accessory shelf.\nSix (6) AK98 Hemodialysis Machines (955607) \nManufacturer: Baxter\nModel: AK98 \nProvide all therapy options including conventional 3x/week, short daily, or nocturnal. \nCapable of sodium profiling \nCapable of bicarbonate profiling.\nCeramic concentrate pumps \nElectromagnetic flow meters. \nAt least 30 minutes of battery backup. \nDirect push-pull capability between the machine and the EMR. \nCapture data every 60 seconds. \nReceive up to 50 treatment parameters. \nInclude integrated formula for automatic calculations. \nStandby mode that does not use any concentrate. \nDoes not require a pH probe for flow rate calculations. \nMachine can self-clear nuisance pressure alarms. \nAutomatic disinfection routines. \nHeat centric disinfection to take no longer than 60 minutes. \nShort heat centric disinfection to take no longer than 30 minutes. \nBleach disinfection to take no longer than 55 minutes. \nHeat disinfection to take no longer than 45 minutes. \nDrain phase included in heat centric, bleach, and heat disinfection programs. \nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min. \nTreatments can be done at a blood flow rate of at least 20 mL/min. \nArterial and Venous pressures monitored and visible on screen. \nTotal weight no greater than 154 lbs. \nHeight no greater than 51.4 inches. \nWidth no larger than 13.6 inches. \nSix (6) Accessory shelf extension kits (956016)\nManufacturer: Baxter\nModel: \nDevice must be able to attach on either side of the device.\nDevice to be no greater than 7.3 inches wide.\nDevice to be no greater than 15 inches deep. \nDevice able to support 73 lbs. or greater. \nAccessories \n\nIMPLEMENTATION AND INSTALLATION \nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation. \nAll materials required to assembly dialysis units and accessory shelf kits shall be provided by the contractor. \nThe contractor will deliver the following quantities of dialysis units and accessories to the addresses below:\nBaltimore VA Medical Center, 10 North Green Street, Baltimore, MD 21201\nSix (6) AK98 Hemodialysis Machines (955607)\nSix (6) Accessory shelf extension kits (956016)\nAccessories \n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\nDELIVERY\nThe contractor shall deliver necessary equipment to the Baltimore facility as required in the quantities specified above. \nThe contractor must give VAMHCS staff 3 weeks  notice of shipment and delivery of the dialysis units, accessory shelf kits, and accessories.  \nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.  \n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format. \n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC). \n\nWARRANTY\nAt a minimum the dialysis units must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government. \nThe warranty shall begin upon completion of validation testing. \nWarranty shall include onsite repairs and over the phone support. \nContractor shall provide routine maintenance service program during warranty period. \nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\nSalient Characteristics   Dialysis Unit\nDialysis Unit\n  Provide all therapy options including conventional 3x/week, short daily, or nocturnal. \n  Capable of sodium profiling \n  Capable of bicarbonate profiling.\n  Ceramic concentrate pumps \n  Electromagnetic flow meters. \n  At least 30 minutes of battery backup. \n  Direct push-pull capability between the machine and the EMR. \n  Capture data every 60 seconds. \n  Receive up to 50 treatment parameters. \n  Include integrated formula for automatic calculations. \n  Standby mode that does not use any concentrate. \n  Does not require a pH probe for flow rate calculations. \n  Machine can self-clear nuisance pressure alarms. \n  Automatic disinfection routines. \n  Heat centric disinfection to take no longer than 60 minutes. \n  Short heat centric disinfection to take no longer than 30 minutes. \n  Bleach disinfection to take no longer than 55 minutes. \n  Heat disinfection to take no longer than 45 minutes. \n  Drain phase included in heat centric, bleach, and heat disinfection programs. \n  Can monitor Kt/V in each treatment simultaneously.\n  Treatments can be done at a flow rate of up to 800 mL/min. \n  Treatments can be done at a blood flow rate of at least 20 mL/min. \n  Arterial and Venous pressures monitored and visible on screen. \n  Total weight no greater than 154 lbs. \n  Height no greater than 51.4 inches. \n  Width no larger than 13.6 inches. \n  Shelf to hold RO unit to be accessible on either side of the device.\n  Shelf to hold RO unit to be at or greater than 7.3 inches wide.\n  Shelf to hold RO unit to be at or greater than 15 inches deep. \n  Shelf to hold RO unit to be able to support 73 lbs. or greater.","text":"The VA Medical Center is conducting this Sources Sought to identify contractors who possess capabilities to provide the product described in the specification below.\nAs permitted by the FAR Part 10, this is a market research tool being utilized for the informational and planning purposes. Your responses will assist the Government in the development of its acquisition strategy.\nResponse is strictly voluntary it is not mandatory to submit a response to this notice to participate in formal RFQ process that may take place in the future. However, it should be noted that information gathered through this notice may significantly influence our acquisition strategy. All interested parties will be required to respond separately to any solicitation posted because of this sources sought notice.\nRespondents will not be notified of the results of the evaluation. We appreciate your interest and thank you in advance for responding to the sources sought.\nThis service will be implemented using the North American Industry Classification System (NAICS) Code 339112.\nRespondents who are supply information from a GSA contract please provide your contract number and category number in your response.\nNOTES\nAll Capability Statements/Responses to this Sources Sought Notice shall be submitted via email only to joseph.krupa@va.gov. Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted. Responses to this Sources Sought Notice must be received no later than March 7, 2025, at 12:00 p.m. (Eastern Standard Time). This Sources Sought Notice may or may not assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced later, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought Notice.\n\nDISCLAIMER\nThis RFI is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.\n\nStatement of Work\nAK98 Hemodialysis Machine\nVA Maryland Health Care System\nBaltimore, MD\n11/18/2024\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure six AK98 Hemodialysis\nMachines with six accessory shelf extension kits for WRO. These machines are utilized for dialysis treatments capable of both sodium and bicarbonate profiling for continued care of veteran patients at the Baltimore VA Medical Center. The current dialysis machines utilized for kidney care at the VAMHCS are being recalled for overheating and burnt power sources. If these replacements are not purchased, these dialysis units will soon no longer be able to be utilized at the VAMHCS and veterans will have to travel to another facility for proper care. These new hemodialysis machines provide a higher URF for more efficient dialysis use and decrease the number of treatments for improved patient experience. Each AK98 Hemodialysis Machine will include an accessory shelf extension for portable RO transport with the machine to save space and increase mobility. The primary function of these hemodialysis machines are to treat kidney failure by filtering out toxins and purifying the blood in the body. Key criteria include system size, push-pull capability, battery life, range of therapy options, and system weight.\n\nSCOPE:\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope.\nThe contractor shall deliver the system to the Baltimore VA Medical center.\nThe assembly and validation of the system must be performed by a vendor service trained representative.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the dialysis units to be successfully installed and validated to their full potential.\nThe contractor shall include accessories and consumables that have been detailed on the provided quotes.\nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to or exceed the Baxter AK98 Hemodialysis Machine + Accessory shelf.\nSix (6) AK98 Hemodialysis Machines (955607)\nManufacturer: Baxter\nModel: AK98\nProvide all therapy options including conventional 3x/week, short daily, or nocturnal.\nCapable of sodium profiling\nCapable of bicarbonate profiling.\nCeramic concentrate pumps\nElectromagnetic flow meters.\nAt least 30 minutes of battery backup.\nDirect push-pull capability between the machine and the EMR.\nCapture data every 60 seconds.\nReceive up to 50 treatment parameters.\nInclude integrated formula for automatic calculations.\nStandby mode that does not use any concentrate.\nDoes not require a pH probe for flow rate calculations.\nMachine can self-clear nuisance pressure alarms.\nAutomatic disinfection routines.\nHeat centric disinfection to take no longer than 60 minutes.\nShort heat centric disinfection to take no longer than 30 minutes.\nBleach disinfection to take no longer than 55 minutes.\nHeat disinfection to take no longer than 45 minutes.\nDrain phase included in heat centric, bleach, and heat disinfection programs.\nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min.\nTreatments can be done at a blood flow rate of at least 20 mL/min.\nArterial and Venous pressures monitored and visible on screen.\nTotal weight no greater than 154 lbs.\nHeight no greater than 51.4 inches.\nWidth no larger than 13.6 inches.\nSix (6) Accessory shelf extension kits (956016)\nManufacturer: Baxter\nModel:\nDevice must be able to attach on either side of the device.\nDevice to be no greater than 7.3 inches wide.\nDevice to be no greater than 15 inches deep.\nDevice able to support 73 lbs. or greater.\nAccessories\n\nIMPLEMENTATION AND INSTALLATION\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation.\nAll materials required to assembly dialysis units and accessory shelf kits shall be provided by the contractor.\nThe contractor will deliver the following quantities of dialysis units and accessories to the addresses below:\nBaltimore VA Medical Center, 10 North Green Street, Baltimore, MD 21201\nSix (6) AK98 Hemodialysis Machines (955607)\nSix (6) Accessory shelf extension kits (956016)\nAccessories\n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\nDELIVERY\nThe contractor shall deliver necessary equipment to the Baltimore facility as required in the quantities specified above.\nThe contractor must give VAMHCS staff 3 weeks notice of shipment and delivery of the dialysis units, accessory shelf kits, and accessories.\nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.\n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC).\n\nWARRANTY\nAt a minimum the dialysis units must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government.\nThe warranty shall begin upon completion of validation testing.\nWarranty shall include onsite repairs and over the phone support.\nContractor shall provide routine maintenance service program during warranty period.\nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nSalient Characteristics Dialysis Unit\nDialysis Unit\nProvide all therapy options including conventional 3x/week, short daily, or nocturnal.\nCapable of sodium profiling\nCapable of bicarbonate profiling.\nCeramic concentrate pumps\nElectromagnetic flow meters.\nAt least 30 minutes of battery backup.\nDirect push-pull capability between the machine and the EMR.\nCapture data every 60 seconds.\nReceive up to 50 treatment parameters.\nInclude integrated formula for automatic calculations.\nStandby mode that does not use any concentrate.\nDoes not require a pH probe for flow rate calculations.\nMachine can self-clear nuisance pressure alarms.\nAutomatic disinfection routines.\nHeat centric disinfection to take no longer than 60 minutes.\nShort heat centric disinfection to take no longer than 30 minutes.\nBleach disinfection to take no longer than 55 minutes.\nHeat disinfection to take no longer than 45 minutes.\nDrain phase included in heat centric, bleach, and heat disinfection programs.\nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min.\nTreatments can be done at a blood flow rate of at least 20 mL/min.\nArterial and Venous pressures monitored and visible on screen.\nTotal weight no greater than 154 lbs.\nHeight no greater than 51.4 inches.\nWidth no larger than 13.6 inches.\nShelf to hold RO unit to be accessible on either side of the device.\nShelf to hold RO unit to be at or greater than 7.3 inches wide.\nShelf to hold RO unit to be at or greater than 15 inches deep.\nShelf to hold RO unit to be able to support 73 lbs. or greater.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0340","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"VA Maryland Health Care System Baltimore VA Medical Center (512)","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 North Greene Street"},"product_service_code":"6515"}],"due_at":"2025-03-07T17:00:00Z","due_date":"2025-03-07","closes_at":"2025-03-07T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-21T13:40:42.992333Z","principal_notice_id":"370ea5592d234cb19e69a3efbdd1e405","description":{"text":"The VA Medical Center is conducting this Sources Sought to identify contractors who possess capabilities to provide the product described in the specification below.\nAs permitted by the FAR Part 10, this is a market research tool being utilized for the informational and planning purposes. Your responses will assist the Government in the development of its acquisition strategy.\nResponse is strictly voluntary it is not mandatory to submit a response to this notice to participate in formal RFQ process that may take place in the future. However, it should be noted that information gathered through this notice may significantly influence our acquisition strategy. All interested parties will be required to respond separately to any solicitation posted because of this sources sought notice.\nRespondents will not be notified of the results of the evaluation. We appreciate your interest and thank you in advance for responding to the sources sought.\nThis service will be implemented using the North American Industry Classification System (NAICS) Code 339112.\nRespondents who are supply information from a GSA contract please provide your contract number and category number in your response.\nNOTES\nAll Capability Statements/Responses to this Sources Sought Notice shall be submitted via email only to joseph.krupa@va.gov. Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted. Responses to this Sources Sought Notice must be received no later than March 7, 2025, at 12:00 p.m. (Eastern Standard Time). This Sources Sought Notice may or may not assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced later, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought Notice.\n\nDISCLAIMER\nThis RFI is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.\n\nStatement of Work\nAK98 Hemodialysis Machine\nVA Maryland Health Care System\nBaltimore, MD\n11/18/2024\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure six AK98 Hemodialysis\nMachines with six accessory shelf extension kits for WRO. These machines are utilized for dialysis treatments capable of both sodium and bicarbonate profiling for continued care of veteran patients at the Baltimore VA Medical Center. The current dialysis machines utilized for kidney care at the VAMHCS are being recalled for overheating and burnt power sources. If these replacements are not purchased, these dialysis units will soon no longer be able to be utilized at the VAMHCS and veterans will have to travel to another facility for proper care. These new hemodialysis machines provide a higher URF for more efficient dialysis use and decrease the number of treatments for improved patient experience. Each AK98 Hemodialysis Machine will include an accessory shelf extension for portable RO transport with the machine to save space and increase mobility. The primary function of these hemodialysis machines are to treat kidney failure by filtering out toxins and purifying the blood in the body. Key criteria include system size, push-pull capability, battery life, range of therapy options, and system weight.\n\nSCOPE:\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope.\nThe contractor shall deliver the system to the Baltimore VA Medical center.\nThe assembly and validation of the system must be performed by a vendor service trained representative.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the dialysis units to be successfully installed and validated to their full potential.\nThe contractor shall include accessories and consumables that have been detailed on the provided quotes.\nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to or exceed the Baxter AK98 Hemodialysis Machine + Accessory shelf.\nSix (6) AK98 Hemodialysis Machines (955607)\nManufacturer: Baxter\nModel: AK98\nProvide all therapy options including conventional 3x/week, short daily, or nocturnal.\nCapable of sodium profiling\nCapable of bicarbonate profiling.\nCeramic concentrate pumps\nElectromagnetic flow meters.\nAt least 30 minutes of battery backup.\nDirect push-pull capability between the machine and the EMR.\nCapture data every 60 seconds.\nReceive up to 50 treatment parameters.\nInclude integrated formula for automatic calculations.\nStandby mode that does not use any concentrate.\nDoes not require a pH probe for flow rate calculations.\nMachine can self-clear nuisance pressure alarms.\nAutomatic disinfection routines.\nHeat centric disinfection to take no longer than 60 minutes.\nShort heat centric disinfection to take no longer than 30 minutes.\nBleach disinfection to take no longer than 55 minutes.\nHeat disinfection to take no longer than 45 minutes.\nDrain phase included in heat centric, bleach, and heat disinfection programs.\nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min.\nTreatments can be done at a blood flow rate of at least 20 mL/min.\nArterial and Venous pressures monitored and visible on screen.\nTotal weight no greater than 154 lbs.\nHeight no greater than 51.4 inches.\nWidth no larger than 13.6 inches.\nSix (6) Accessory shelf extension kits (956016)\nManufacturer: Baxter\nModel:\nDevice must be able to attach on either side of the device.\nDevice to be no greater than 7.3 inches wide.\nDevice to be no greater than 15 inches deep.\nDevice able to support 73 lbs. or greater.\nAccessories\n\nIMPLEMENTATION AND INSTALLATION\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation.\nAll materials required to assembly dialysis units and accessory shelf kits shall be provided by the contractor.\nThe contractor will deliver the following quantities of dialysis units and accessories to the addresses below:\nBaltimore VA Medical Center, 10 North Green Street, Baltimore, MD 21201\nSix (6) AK98 Hemodialysis Machines (955607)\nSix (6) Accessory shelf extension kits (956016)\nAccessories\n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\nDELIVERY\nThe contractor shall deliver necessary equipment to the Baltimore facility as required in the quantities specified above.\nThe contractor must give VAMHCS staff 3 weeks notice of shipment and delivery of the dialysis units, accessory shelf kits, and accessories.\nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.\n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC).\n\nWARRANTY\nAt a minimum the dialysis units must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government.\nThe warranty shall begin upon completion of validation testing.\nWarranty shall include onsite repairs and over the phone support.\nContractor shall provide routine maintenance service program during warranty period.\nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nSalient Characteristics Dialysis Unit\nDialysis Unit\nProvide all therapy options including conventional 3x/week, short daily, or nocturnal.\nCapable of sodium profiling\nCapable of bicarbonate profiling.\nCeramic concentrate pumps\nElectromagnetic flow meters.\nAt least 30 minutes of battery backup.\nDirect push-pull capability between the machine and the EMR.\nCapture data every 60 seconds.\nReceive up to 50 treatment parameters.\nInclude integrated formula for automatic calculations.\nStandby mode that does not use any concentrate.\nDoes not require a pH probe for flow rate calculations.\nMachine can self-clear nuisance pressure alarms.\nAutomatic disinfection routines.\nHeat centric disinfection to take no longer than 60 minutes.\nShort heat centric disinfection to take no longer than 30 minutes.\nBleach disinfection to take no longer than 55 minutes.\nHeat disinfection to take no longer than 45 minutes.\nDrain phase included in heat centric, bleach, and heat disinfection programs.\nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min.\nTreatments can be done at a blood flow rate of at least 20 mL/min.\nArterial and Venous pressures monitored and visible on screen.\nTotal weight no greater than 154 lbs.\nHeight no greater than 51.4 inches.\nWidth no larger than 13.6 inches.\nShelf to hold RO unit to be accessible on either side of the device.\nShelf to hold RO unit to be at or greater than 7.3 inches wide.\nShelf to hold RO unit to be at or greater than 15 inches deep.\nShelf to hold RO unit to be able to support 73 lbs. or greater.","html":"The VA Medical Center is conducting this Sources Sought to identify contractors who possess capabilities to provide the product described in the specification below.  \nAs permitted by the FAR Part 10, this is a market research tool being utilized for the informational and planning purposes.  Your responses will assist the Government in the development of its acquisition strategy.  \nResponse is strictly voluntary   it is not mandatory to submit a response to this notice to participate in formal RFQ process that may take place in the future.  However, it should be noted that information gathered through this notice may significantly influence our acquisition strategy. All interested parties will be required to respond separately to any solicitation posted because of this sources sought notice. \nRespondents will not be notified of the results of the evaluation.  We appreciate your interest and thank you in advance for responding to the sources sought. \nThis service will be implemented using the North American Industry Classification System (NAICS) Code 339112.   \nRespondents who are supply information from a GSA contract please provide your contract number and category number in your response.\n  NOTES\nAll Capability Statements/Responses to this Sources Sought Notice shall be submitted via email only to joseph.krupa@va.gov. Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted. Responses to this Sources Sought Notice must be received no later than March 7, 2025, at 12:00 p.m. (Eastern Standard Time). This Sources Sought Notice may or may not assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced later, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought Notice.\n\nDISCLAIMER\nThis RFI is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.\n\n\n\n\nStatement of Work\nAK98 Hemodialysis Machine\nVA Maryland Health Care System\nBaltimore, MD\n11/18/2024\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure six AK98 Hemodialysis\nMachines with six accessory shelf extension kits for WRO. These machines are utilized for dialysis treatments capable of both sodium and bicarbonate profiling for continued care of veteran patients at the Baltimore VA Medical Center. The current dialysis machines utilized for kidney care at the VAMHCS are being recalled for overheating and burnt power sources. If these replacements are not purchased, these dialysis units will soon no longer be able to be utilized at the VAMHCS and veterans will have to travel to another facility for proper care. These new hemodialysis machines provide a higher URF for more efficient dialysis use and decrease the number of treatments for improved patient experience. Each AK98 Hemodialysis Machine will include an accessory shelf extension for portable RO transport with the machine to save space and increase mobility. The primary function of these hemodialysis machines are to treat kidney failure by filtering out toxins and purifying the blood in the body. Key criteria include system size, push-pull capability, battery life, range of therapy options, and system weight. \n\n\nSCOPE: \nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted. \nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope. \nThe contractor shall deliver the system to the Baltimore VA Medical center. \nThe assembly and validation of the system must be performed by a vendor service trained representative. \nThe contractor is responsible for identifying any missing parts or components not included in the order for the dialysis units to be successfully installed and validated to their full potential. \nThe contractor shall include accessories and consumables that have been detailed on the provided quotes. \nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to or exceed the Baxter AK98 Hemodialysis Machine + Accessory shelf.\nSix (6) AK98 Hemodialysis Machines (955607) \nManufacturer: Baxter\nModel: AK98 \nProvide all therapy options including conventional 3x/week, short daily, or nocturnal. \nCapable of sodium profiling \nCapable of bicarbonate profiling.\nCeramic concentrate pumps \nElectromagnetic flow meters. \nAt least 30 minutes of battery backup. \nDirect push-pull capability between the machine and the EMR. \nCapture data every 60 seconds. \nReceive up to 50 treatment parameters. \nInclude integrated formula for automatic calculations. \nStandby mode that does not use any concentrate. \nDoes not require a pH probe for flow rate calculations. \nMachine can self-clear nuisance pressure alarms. \nAutomatic disinfection routines. \nHeat centric disinfection to take no longer than 60 minutes. \nShort heat centric disinfection to take no longer than 30 minutes. \nBleach disinfection to take no longer than 55 minutes. \nHeat disinfection to take no longer than 45 minutes. \nDrain phase included in heat centric, bleach, and heat disinfection programs. \nCan monitor Kt/V in each treatment simultaneously.\nTreatments can be done at a flow rate of up to 800 mL/min. \nTreatments can be done at a blood flow rate of at least 20 mL/min. \nArterial and Venous pressures monitored and visible on screen. \nTotal weight no greater than 154 lbs. \nHeight no greater than 51.4 inches. \nWidth no larger than 13.6 inches. \nSix (6) Accessory shelf extension kits (956016)\nManufacturer: Baxter\nModel: \nDevice must be able to attach on either side of the device.\nDevice to be no greater than 7.3 inches wide.\nDevice to be no greater than 15 inches deep. \nDevice able to support 73 lbs. or greater. \nAccessories \n\nIMPLEMENTATION AND INSTALLATION \nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation. \nAll materials required to assembly dialysis units and accessory shelf kits shall be provided by the contractor. \nThe contractor will deliver the following quantities of dialysis units and accessories to the addresses below:\nBaltimore VA Medical Center, 10 North Green Street, Baltimore, MD 21201\nSix (6) AK98 Hemodialysis Machines (955607)\nSix (6) Accessory shelf extension kits (956016)\nAccessories \n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\nDELIVERY\nThe contractor shall deliver necessary equipment to the Baltimore facility as required in the quantities specified above. \nThe contractor must give VAMHCS staff 3 weeks  notice of shipment and delivery of the dialysis units, accessory shelf kits, and accessories.  \nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.  \n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format. \n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC). \n\nWARRANTY\nAt a minimum the dialysis units must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government. \nThe warranty shall begin upon completion of validation testing. \nWarranty shall include onsite repairs and over the phone support. \nContractor shall provide routine maintenance service program during warranty period. \nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\nSalient Characteristics   Dialysis Unit\nDialysis Unit\n  Provide all therapy options including conventional 3x/week, short daily, or nocturnal. \n  Capable of sodium profiling \n  Capable of bicarbonate profiling.\n  Ceramic concentrate pumps \n  Electromagnetic flow meters. \n  At least 30 minutes of battery backup. \n  Direct push-pull capability between the machine and the EMR. \n  Capture data every 60 seconds. \n  Receive up to 50 treatment parameters. \n  Include integrated formula for automatic calculations. \n  Standby mode that does not use any concentrate. \n  Does not require a pH probe for flow rate calculations. \n  Machine can self-clear nuisance pressure alarms. \n  Automatic disinfection routines. \n  Heat centric disinfection to take no longer than 60 minutes. \n  Short heat centric disinfection to take no longer than 30 minutes. \n  Bleach disinfection to take no longer than 55 minutes. \n  Heat disinfection to take no longer than 45 minutes. \n  Drain phase included in heat centric, bleach, and heat disinfection programs. \n  Can monitor Kt/V in each treatment simultaneously.\n  Treatments can be done at a flow rate of up to 800 mL/min. \n  Treatments can be done at a blood flow rate of at least 20 mL/min. \n  Arterial and Venous pressures monitored and visible on screen. \n  Total weight no greater than 154 lbs. \n  Height no greater than 51.4 inches. \n  Width no larger than 13.6 inches. \n  Shelf to hold RO unit to be accessible on either side of the device.\n  Shelf to hold RO unit to be at or greater than 7.3 inches wide.\n  Shelf to hold RO unit to be at or greater than 15 inches deep. \n  Shelf to hold RO unit to be able to support 73 lbs. or greater.","origin":"detail"},"contacts":[{"name":"Joseph J. Krupa","role":"primary","email":"joseph.krupa@va.gov","phone":"(304) 263-0811 ext.7618","title":"Contracting Officer"}],"place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"VA Maryland Health Care System Baltimore VA Medical Center (512)","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 North Greene Street"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"9bf8253b723f480b806f5df99d22de87","name":"36C24525Q0340.docx","kind":"file","mime_type":".docx","size_bytes":30845,"posted_at":"2025-02-26T22:16:24.249Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9bf8253b723f480b806f5df99d22de87/download","mirrored":false},{"resource_id":"72750371b0514713bdf206f5db0ffd9e","name":"VA Home Page","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-02-26T22:16:24.249Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27001101","latest_notice_id":"352f21577e56484e9a1121550b56e448","title":"Intent to Sole Source - TELEMED ArtUs EXT-2H ultrasound system with RF module, two ultrasound transducers, and a ProbeFix Dynamic T probe holder","solicitation_number":"NOI-OLAO-CC-27-001101","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"339112","psc":"6515","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"75N98027Q00038SBPCANIA11810","latest_notice_id":"427cad0cab794e55b2ddb3fe92acc285","title":"Baxter/Hill-Rom Helux Pro Surgical Light System","solicitation_number":"75N98027Q00038SB_PCA-NIA-11810","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-08T19:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"339112","psc":"6515","set_aside":"SBA","state":"MD","county":"24003","county_name":"Anne Arundel County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":14,"indexable":false}