{"canonical":"https://sealedbidder.com/opportunities/36c24525q0333","key":"36C24525Q0333","url":"https://sealedbidder.com/opportunities/36c24525q0333","title":"J065--AUDIOLOGY BOOTH FOR BALTIMORE VAMC \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\". MUST PROVIDE OEM AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER.","solicitation_number":"36C24525Q0333","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-28T19:00:00Z","first_posted":"2025-02-21","last_posted":"2025-02-21","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"J065","set_aside":null,"place_state":"MD","place_scope":"site","site":"Baltimore VA Medical Center","place_state_source":"sam_street","place_evidence":"BALTIMORE VAMC - CAMBRIDGE CBOC 830 CHESAPEAKE DRIVE CAMBRIDGE, MD 21613","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","title":"J065--AUDIOLOGY BOOTH FOR BALTIMORE VAMC \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\". MUST PROVIDE OEM AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER.","solicitation_number":"36C24525Q0333","notice_type":"r","base_type":"r","posted":"2025-02-21","posted_at":"2025-02-21T20:15:56.564Z","due_at":"2025-02-28T19:00:00Z","due_date":"2025-02-28","cancelled":false,"archived":true,"archive_date":"2025-03-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/afaad2e1ec014fcf848d7c0f4d75b4a8/view","enriched":true,"history":[{"index":3,"title":"J065--AUDIOLOGY BOOTH FOR BALTIMORE VAMC \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\". MUST PROVIDE OEM AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-21T20:15:56.564Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","solicitation_number":"36C24525Q0333"}]}],"latest_notice_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-21","posted_at":"2025-02-21T20:15:56.564Z","created_at":"2025-02-21T20:15:25.256Z","modified_at":"2025-03-11T03:55:45.067Z","response_deadline":{"raw":"2025-02-28T14:00:00-05:00","utc":"2025-02-28T19:00:00Z","date":"2025-02-28","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/afaad2e1ec014fcf848d7c0f4d75b4a8/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"J065--AUDIOLOGY BOOTH FOR BALTIMORE VAMC \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\". MUST PROVIDE OEM AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER.","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--AUDIOLOGY BOOTH FOR BALTIMORE VAMC \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\". MUST PROVIDE OEM AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-21T20:15:56.564Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","solicitation_number":"36C24525Q0333"}],"contacts":[{"name":"Mohsin Abbas","role":"primary","email":"Mohsin.Abbas2@va.gov","phone":"202-745-8000 x54945","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","lineage_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T03:16:34.873685947Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"1f09d03b52afa930023bd1ded675c222b0388a8131b805b59bb74b52712a6c07","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T03:16:34.873685947Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\n AUDIOLOGY BOOTH   BALTIMORE VAMC - CAMBRIDGE CBOC\n\n  BRAND NAME OR EQUAL TO ECKEL IAW STATEMENT OF WORK \n\n MUST PROVIDE AN AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE   MANUFACTURER AT THE TIME RFI WILL CLOSE TO QUALIFY FOR THIS SOLICITATION . \n\n MUST PROVIDE THE COUNTRY OF ORIGIN (COO) FOR EACH LINE ITEM  \n\nThis is a requirement for: \n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\n\nDESCRIPTION: \n\nThe Baltimore CBOC VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBaltimore VA Medical Center\nCambridge CBOC\nWAREHOUSE/ATTN: \n830 Chesapeake Drive\nCambridge, MD 21613\n\n\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government. \nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey. \nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded. \n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI? \n\nAre you the manufacturer or distributor of the items being referenced above? \n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly \n\n    (1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n          (2) __ Outside the United States.\n\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\n Legal Business/Company Name (as it is indicated in https://sam.gov ).\n\n Unique Entity ID UEI (SAM) & DUNS Number.\n\n Warranty Information (Can be a separate attachment).\n\n Point of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO. \n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase. \nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award. \n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov.  No Telephone responses shall not be accepted. Responses must be received no later than Friday, Feb 28, 2025, by 2:00 PM (EST). \n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\n\nSTATEMENT OF WORK (SOW)\nAUDIOLOGY BOOTH\nVA MARYLAND HEALTH CARE SYSTEM\nBALTIMORE, MD\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure and install an audiology booth at the Cambridge VA Clinic. This new audiology booth will replace a nonfunctional audiology booth. The audiology booth will provide a soundproof suite for patients and employees to conduct hearing exams in an isolated area for precise results. The primary function of the audiology booth is to provide an isolated acoustical room to measure hearing acuity in patients. Isolated acoustic rooms are crucial to eliminating background noise to acquire a reliable diagnosis in patients. Audiology booth will include a rubber ramp for wheelchair access. Key criteria include system size, weight, and acoustic installation. \n\nSCOPE: \nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted. \nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope. \nThe contractor shall deliver the audiology booth to the Cambridge facility as specified below. \nThe assembly and validation of the system must be performed by a vendor service trained representative. \nThe contractor is responsible for identifying any missing parts or components not included in the order for the audiology booth to be successfully installed and validated to their full potential. \nThe contractor shall include accessories and consumables that have been detailed on the provided quotes. \nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to Eckel Noise Control Technologies Audiology Booth. \nOne CL-123 PR Sing Wall Cont, Double Wall Exam Suite \nManufacturer: Eckel Noise Control Technologies\nModel: CL-123 FP7 PRIME\nMust include an acoustically engineered independent ventilation system that is mounted external to the unit. \nUnit provides recessed incandescent lighting. \nUnit must have an acoustic door with cam -lift hinges, providing at least 914 mm x 2032 mm (36  x 80 ) clear opening. \nMust include a double glazed, safety glass window that is at least 6 mm (1/4 ) thick and at least 762 mm x 762 mm (30  x 30 ). \nUnit must be electrically serviced via a grounded cable, having a length of at least 20 feet. \nUnit floor must be acoustically isolated in both the control and exam room. \nUnit must have a noise reduction coefficient of 1.05, while having an absorption coefficient range of 0.79-1.10 when measuring the center frequency (Hz) between a range of 125-400 Hz. \nNoise reduction in a double wall room must be able to reduce the center frequency (Hz) of 2000Hz and 4000Hz to 100, 125Hz to 44, 250Hz to 62, 500Hz to 81, 1000Hz to 93, and 8000Hz to 95. Noise reduction measured from the outside to the inside. \nDoor size must be at least 36  W by 80 H clear opening. \nDoor handles must be a C-shape while providing a minimum clearance of 1 Â½  behind it. \nDoors cannot require more than 5psi constant pressure to open, once the magnetic seal is broken. \nDouble glazes acoustic windows for the doors on the booth, size options must include: 20  W by 22 H or 20  W by 60  H. \nUnit includes a standard fan exhaust and fan inlet silencers suspended to the ceiling. Silencers mist be capable of 10 to 12 full air exchanges per hour. Fans include a 6  or 8  diameter HVAC collar option. \nUnit must include two ventilation silencers built into the booth s ceilings, one supply and one exhaust provided. \nUnit must include an accessible jack panel that provides at least 12 (TRS 3-wire), Â¼  phone jacks, two USB ports, and 1 Â¾  pass through. Panel face must be removable and does not impact the rooms acoustical performance. \nTotal rise from the host floor to the door opening must be no larger than 7 Â½ . \nSprinkler holes must be at least 3  in diameter. \nUnit must by supplied with standard carpet or carpet tile in both rooms. \nMust be able to provide empty utility boxes with pull wires for data, thermostats, and alarms. \nRoom must require no more than 120V, 15/20 AMP, or 60 Hz supply circuit. \nUnit must provide at least 2 duplex outlets and light/fan switches. \nUnit wall panels must be at least 4  thick in both rooms. \nUnit ceiling panels must be at least 6  thick in both rooms.\nBoth the control and exam room must have a minimum clear interior height of 83  for all features attached to the ceiling panels. \nLight switches must be at least 44  from the floor inside of the unit, in both rooms. \nOutlets must be at least 15  from the floor inside of the unit, in both rooms. \nMust include rubber mat as floors inside the booth at a height no greater than 10mm (3/8 ) height for wheelchair access. \nBooth doors must be at least 75 mm (2 7/8 ) thick. \nBooth doors mounted with heavy duty cam lift hinges. \nDoor sealing system must have at least a double magnetic gasket sealing system and flush sill seal design for an accurate acoustic seal. \nBoth rooms must have at least a 60  minimum turning radius for wheelchair access.\nPanels in the unit must have a Flame Spread rating of 3.\nPanels in the unit must have a Smoke Density Rating of 2.\nBoth the control and exam room must come with standard sprinkler penetrations for onsite installation. \nAll electrical in the unit must be Hospital Grade. \nUnit wall shells must be fabricated with cold rolled steel frames (14 ga) and steel outer surfaces (16 ga). \nFraming members on unit wall shell should not be spaced out any further than 610 mm (24 ) centers. \nUnit wall inner panels should be fabricated with cold rolled steel (22 ga) that includes holes no greater than 2.4 mm (3/32 ) diameter, where holes are staggered on 4 mm (5/32 ) centers. \nPanels must interlock and provide an acoustic seal that utilizes a minimum of two sets of closed cell acoustic rubber seals and at least two interlocking panel connectors.\n\nIMPLEMENTATION AND INSTALLATION \nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation. \nAll materials required to assemble the audiology booth shall be provided by the contractor. \nThe contractor will deliver the audiology booth and accessories to the addresses below:\nCambridge VA Outpatient Clinic, 830 Chesapeake Drive, Cambridge, MD 21613-9408\nOne (1) Audiology Booth, Sloped Rubber Ramp\nAccessories\n\nTRAINING \nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\n\nDELIVERY \nThe contractor shall deliver necessary equipment to the Cambridge VA facility as required in the quantity specified above. \nThe contractor must deliver the audiology booth to the Cambridge facility with a small bed truck that has a lift because this location does not have a loading dock. \nThe contractor must give VAMHCS staff 3 weeks  notice of shipment and delivery of the audiology booth and accessories.  \nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. Installation can proceed 90 days after award of contract. \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.  \n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format. \n\nOPERATOR TRAINING \nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC). \n\nWARRANTY\nAt a minimum the audiology booth must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government. \nThe warranty shall begin upon completion of validation testing. \nWarranty shall include onsite repairs and over the phone support. \nContractor shall provide routine maintenance service program during warranty period. \nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nLINE-ITEM DESCRIPTION\n\nAUDIOLOGY BOOTH FOR BALTIMORE CBOC VAMC\n\n BRAND NAME OR EQUAL TO ECKEL IAW SOW \n\nB.3 PRICE/COST SCHEDULE\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nEA\n__________________\n__________________\n\nCL-123 PR Sing Wall Cont, Double Wall Exam Suite / 1001354\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001354\nLOCAL STOCK NUMBER: 1001354\n\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nLBR-Sound Room Relocation/Installation 1000033\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1000033\nLOCAL STOCK NUMBER: 1000033\n\n\n0003\n\n2.00\nEA\n__________________\n__________________\n\nEAO-A-003 Add-On Add - Wall Fascia Closure Angles 1001408\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001408\nLOCAL STOCK NUMBER: 1001408\n\n\n0004\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-004 Add-On Door - Window in Door 20\"W x 22\"H 1001416 \n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001416\nLOCAL STOCK NUMBER: 1001416\n\n\n0005\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-007 Add-Ons - Door - Magnetic Door Holder 1001418\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001418\nLOCAL STOCK NUMBER: 1001418\n\n\n0006\n\n2.00\nEA\n__________________\n__________________\n\nEAO-U-003 Add-On Utilities - Light Dimmer Switch 1001425\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001425\nLOCAL STOCK NUMBER: 1001425\n\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEAO-U-005 Add-On Util Sprinkler Hole Double Wall 1001427\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001427\nLOCAL STOCK NUMBER: 1001427\n\n\n0008\n\n1.00\nSE\n__________________\n__________________\n\nEAO-U-007 Add-On Utilities - HVAC Collars (2 Sets) 1001429\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001429\nLOCAL STOCK NUMBER: 1001429\n\n\n0009\n\n2.00\nBX\n__________________\n__________________\n\nEAO-U-002 Add-On Util Rough Ins (Box w. Pull wire) 1001424\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001424\nLOCAL STOCK NUMBER: 1001424\n\n\n\n\n\n\nGRAND TOTAL\n__________________","text":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\nAUDIOLOGY BOOTH BALTIMORE VAMC - CAMBRIDGE CBOC\n\nBRAND NAME OR EQUAL TO ECKEL IAW STATEMENT OF WORK\n\nMUST PROVIDE AN AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER AT THE TIME RFI WILL CLOSE TO QUALIFY FOR THIS SOLICITATION .\n\nMUST PROVIDE THE COUNTRY OF ORIGIN (COO) FOR EACH LINE ITEM\n\nThis is a requirement for:\n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION:\n\nThe Baltimore CBOC VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBaltimore VA Medical Center\nCambridge CBOC\nWAREHOUSE/ATTN:\n830 Chesapeake Drive\nCambridge, MD 21613\n\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government.\nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey.\nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded.\n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above?\n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly\n\n(1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n(2) __ Outside the United States.\n\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nLegal Business/Company Name (as it is indicated in https://sam.gov ).\n\nUnique Entity ID UEI (SAM) & DUNS Number.\n\nWarranty Information (Can be a separate attachment).\n\nPoint of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO.\n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase.\nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award.\n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov. No Telephone responses shall not be accepted. Responses must be received no later than Friday, Feb 28, 2025, by 2:00 PM (EST).\n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\nSTATEMENT OF WORK (SOW)\nAUDIOLOGY BOOTH\nVA MARYLAND HEALTH CARE SYSTEM\nBALTIMORE, MD\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure and install an audiology booth at the Cambridge VA Clinic. This new audiology booth will replace a nonfunctional audiology booth. The audiology booth will provide a soundproof suite for patients and employees to conduct hearing exams in an isolated area for precise results. The primary function of the audiology booth is to provide an isolated acoustical room to measure hearing acuity in patients. Isolated acoustic rooms are crucial to eliminating background noise to acquire a reliable diagnosis in patients. Audiology booth will include a rubber ramp for wheelchair access. Key criteria include system size, weight, and acoustic installation.\n\nSCOPE:\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope.\nThe contractor shall deliver the audiology booth to the Cambridge facility as specified below.\nThe assembly and validation of the system must be performed by a vendor service trained representative.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the audiology booth to be successfully installed and validated to their full potential.\nThe contractor shall include accessories and consumables that have been detailed on the provided quotes.\nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to Eckel Noise Control Technologies Audiology Booth.\nOne CL-123 PR Sing Wall Cont, Double Wall Exam Suite\nManufacturer: Eckel Noise Control Technologies\nModel: CL-123 FP7 PRIME\nMust include an acoustically engineered independent ventilation system that is mounted external to the unit.\nUnit provides recessed incandescent lighting.\nUnit must have an acoustic door with cam -lift hinges, providing at least 914 mm x 2032 mm (36 x 80 ) clear opening.\nMust include a double glazed, safety glass window that is at least 6 mm (1/4 ) thick and at least 762 mm x 762 mm (30 x 30 ).\nUnit must be electrically serviced via a grounded cable, having a length of at least 20 feet.\nUnit floor must be acoustically isolated in both the control and exam room.\nUnit must have a noise reduction coefficient of 1.05, while having an absorption coefficient range of 0.79-1.10 when measuring the center frequency (Hz) between a range of 125-400 Hz.\nNoise reduction in a double wall room must be able to reduce the center frequency (Hz) of 2000Hz and 4000Hz to 100, 125Hz to 44, 250Hz to 62, 500Hz to 81, 1000Hz to 93, and 8000Hz to 95. Noise reduction measured from the outside to the inside.\nDoor size must be at least 36 W by 80 H clear opening.\nDoor handles must be a C-shape while providing a minimum clearance of 1 Â½ behind it.\nDoors cannot require more than 5psi constant pressure to open, once the magnetic seal is broken.\nDouble glazes acoustic windows for the doors on the booth, size options must include: 20 W by 22 H or 20 W by 60 H.\nUnit includes a standard fan exhaust and fan inlet silencers suspended to the ceiling. Silencers mist be capable of 10 to 12 full air exchanges per hour. Fans include a 6 or 8 diameter HVAC collar option.\nUnit must include two ventilation silencers built into the booth s ceilings, one supply and one exhaust provided.\nUnit must include an accessible jack panel that provides at least 12 (TRS 3-wire), Â¼ phone jacks, two USB ports, and 1 Â¾ pass through. Panel face must be removable and does not impact the rooms acoustical performance.\nTotal rise from the host floor to the door opening must be no larger than 7 Â½ .\nSprinkler holes must be at least 3 in diameter.\nUnit must by supplied with standard carpet or carpet tile in both rooms.\nMust be able to provide empty utility boxes with pull wires for data, thermostats, and alarms.\nRoom must require no more than 120V, 15/20 AMP, or 60 Hz supply circuit.\nUnit must provide at least 2 duplex outlets and light/fan switches.\nUnit wall panels must be at least 4 thick in both rooms.\nUnit ceiling panels must be at least 6 thick in both rooms.\nBoth the control and exam room must have a minimum clear interior height of 83 for all features attached to the ceiling panels.\nLight switches must be at least 44 from the floor inside of the unit, in both rooms.\nOutlets must be at least 15 from the floor inside of the unit, in both rooms.\nMust include rubber mat as floors inside the booth at a height no greater than 10mm (3/8 ) height for wheelchair access.\nBooth doors must be at least 75 mm (2 7/8 ) thick.\nBooth doors mounted with heavy duty cam lift hinges.\nDoor sealing system must have at least a double magnetic gasket sealing system and flush sill seal design for an accurate acoustic seal.\nBoth rooms must have at least a 60 minimum turning radius for wheelchair access.\nPanels in the unit must have a Flame Spread rating of 3.\nPanels in the unit must have a Smoke Density Rating of 2.\nBoth the control and exam room must come with standard sprinkler penetrations for onsite installation.\nAll electrical in the unit must be Hospital Grade.\nUnit wall shells must be fabricated with cold rolled steel frames (14 ga) and steel outer surfaces (16 ga).\nFraming members on unit wall shell should not be spaced out any further than 610 mm (24 ) centers.\nUnit wall inner panels should be fabricated with cold rolled steel (22 ga) that includes holes no greater than 2.4 mm (3/32 ) diameter, where holes are staggered on 4 mm (5/32 ) centers.\nPanels must interlock and provide an acoustic seal that utilizes a minimum of two sets of closed cell acoustic rubber seals and at least two interlocking panel connectors.\n\nIMPLEMENTATION AND INSTALLATION\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation.\nAll materials required to assemble the audiology booth shall be provided by the contractor.\nThe contractor will deliver the audiology booth and accessories to the addresses below:\nCambridge VA Outpatient Clinic, 830 Chesapeake Drive, Cambridge, MD 21613-9408\nOne (1) Audiology Booth, Sloped Rubber Ramp\nAccessories\n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\n\nDELIVERY\nThe contractor shall deliver necessary equipment to the Cambridge VA facility as required in the quantity specified above.\nThe contractor must deliver the audiology booth to the Cambridge facility with a small bed truck that has a lift because this location does not have a loading dock.\nThe contractor must give VAMHCS staff 3 weeks notice of shipment and delivery of the audiology booth and accessories.\nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. Installation can proceed 90 days after award of contract.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.\n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC).\n\nWARRANTY\nAt a minimum the audiology booth must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government.\nThe warranty shall begin upon completion of validation testing.\nWarranty shall include onsite repairs and over the phone support.\nContractor shall provide routine maintenance service program during warranty period.\nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nLINE-ITEM DESCRIPTION\n\nAUDIOLOGY BOOTH FOR BALTIMORE CBOC VAMC\n\nBRAND NAME OR EQUAL TO ECKEL IAW SOW\n\nB.3 PRICE/COST SCHEDULE\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nEA\n__________________\n__________________\n\nCL-123 PR Sing Wall Cont, Double Wall Exam Suite / 1001354\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001354\nLOCAL STOCK NUMBER: 1001354\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nLBR-Sound Room Relocation/Installation 1000033\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1000033\nLOCAL STOCK NUMBER: 1000033\n\n0003\n\n2.00\nEA\n__________________\n__________________\n\nEAO-A-003 Add-On Add - Wall Fascia Closure Angles 1001408\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001408\nLOCAL STOCK NUMBER: 1001408\n\n0004\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-004 Add-On Door - Window in Door 20\"W x 22\"H 1001416\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001416\nLOCAL STOCK NUMBER: 1001416\n\n0005\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-007 Add-Ons - Door - Magnetic Door Holder 1001418\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001418\nLOCAL STOCK NUMBER: 1001418\n\n0006\n\n2.00\nEA\n__________________\n__________________\n\nEAO-U-003 Add-On Utilities - Light Dimmer Switch 1001425\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001425\nLOCAL STOCK NUMBER: 1001425\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEAO-U-005 Add-On Util Sprinkler Hole Double Wall 1001427\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001427\nLOCAL STOCK NUMBER: 1001427\n\n0008\n\n1.00\nSE\n__________________\n__________________\n\nEAO-U-007 Add-On Utilities - HVAC Collars (2 Sets) 1001429\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001429\nLOCAL STOCK NUMBER: 1001429\n\n0009\n\n2.00\nBX\n__________________\n__________________\n\nEAO-U-002 Add-On Util Rough Ins (Box w. Pull wire) 1001424\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001424\nLOCAL STOCK NUMBER: 1001424\n\nGRAND TOTAL\n__________________","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0333","place_of_performance":{"zip":"21613","street":"Baltimore VAMC - Cambridge CBOC 830 Chesapeake Drive","street2":"Cambridge, MD 21613"},"product_service_code":"J065"}],"due_at":"2025-02-28T19:00:00Z","due_date":"2025-02-28","closes_at":"2025-02-28T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"BALTIMORE VAMC - CAMBRIDGE CBOC 830 CHESAPEAKE DRIVE CAMBRIDGE, MD 21613","site_key":"baltimore-va-medical-center-md","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-22T03:29:58.815774Z","principal_notice_id":"afaad2e1ec014fcf848d7c0f4d75b4a8","description":{"text":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\nAUDIOLOGY BOOTH BALTIMORE VAMC - CAMBRIDGE CBOC\n\nBRAND NAME OR EQUAL TO ECKEL IAW STATEMENT OF WORK\n\nMUST PROVIDE AN AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE MANUFACTURER AT THE TIME RFI WILL CLOSE TO QUALIFY FOR THIS SOLICITATION .\n\nMUST PROVIDE THE COUNTRY OF ORIGIN (COO) FOR EACH LINE ITEM\n\nThis is a requirement for:\n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\nDESCRIPTION:\n\nThe Baltimore CBOC VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBaltimore VA Medical Center\nCambridge CBOC\nWAREHOUSE/ATTN:\n830 Chesapeake Drive\nCambridge, MD 21613\n\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government.\nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey.\nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded.\n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer or distributor of the items being referenced above?\n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly\n\n(1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n(2) __ Outside the United States.\n\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\nLegal Business/Company Name (as it is indicated in https://sam.gov ).\n\nUnique Entity ID UEI (SAM) & DUNS Number.\n\nWarranty Information (Can be a separate attachment).\n\nPoint of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO.\n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase.\nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award.\n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov. No Telephone responses shall not be accepted. Responses must be received no later than Friday, Feb 28, 2025, by 2:00 PM (EST).\n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\nSTATEMENT OF WORK (SOW)\nAUDIOLOGY BOOTH\nVA MARYLAND HEALTH CARE SYSTEM\nBALTIMORE, MD\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure and install an audiology booth at the Cambridge VA Clinic. This new audiology booth will replace a nonfunctional audiology booth. The audiology booth will provide a soundproof suite for patients and employees to conduct hearing exams in an isolated area for precise results. The primary function of the audiology booth is to provide an isolated acoustical room to measure hearing acuity in patients. Isolated acoustic rooms are crucial to eliminating background noise to acquire a reliable diagnosis in patients. Audiology booth will include a rubber ramp for wheelchair access. Key criteria include system size, weight, and acoustic installation.\n\nSCOPE:\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope.\nThe contractor shall deliver the audiology booth to the Cambridge facility as specified below.\nThe assembly and validation of the system must be performed by a vendor service trained representative.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the audiology booth to be successfully installed and validated to their full potential.\nThe contractor shall include accessories and consumables that have been detailed on the provided quotes.\nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to Eckel Noise Control Technologies Audiology Booth.\nOne CL-123 PR Sing Wall Cont, Double Wall Exam Suite\nManufacturer: Eckel Noise Control Technologies\nModel: CL-123 FP7 PRIME\nMust include an acoustically engineered independent ventilation system that is mounted external to the unit.\nUnit provides recessed incandescent lighting.\nUnit must have an acoustic door with cam -lift hinges, providing at least 914 mm x 2032 mm (36 x 80 ) clear opening.\nMust include a double glazed, safety glass window that is at least 6 mm (1/4 ) thick and at least 762 mm x 762 mm (30 x 30 ).\nUnit must be electrically serviced via a grounded cable, having a length of at least 20 feet.\nUnit floor must be acoustically isolated in both the control and exam room.\nUnit must have a noise reduction coefficient of 1.05, while having an absorption coefficient range of 0.79-1.10 when measuring the center frequency (Hz) between a range of 125-400 Hz.\nNoise reduction in a double wall room must be able to reduce the center frequency (Hz) of 2000Hz and 4000Hz to 100, 125Hz to 44, 250Hz to 62, 500Hz to 81, 1000Hz to 93, and 8000Hz to 95. Noise reduction measured from the outside to the inside.\nDoor size must be at least 36 W by 80 H clear opening.\nDoor handles must be a C-shape while providing a minimum clearance of 1 Â½ behind it.\nDoors cannot require more than 5psi constant pressure to open, once the magnetic seal is broken.\nDouble glazes acoustic windows for the doors on the booth, size options must include: 20 W by 22 H or 20 W by 60 H.\nUnit includes a standard fan exhaust and fan inlet silencers suspended to the ceiling. Silencers mist be capable of 10 to 12 full air exchanges per hour. Fans include a 6 or 8 diameter HVAC collar option.\nUnit must include two ventilation silencers built into the booth s ceilings, one supply and one exhaust provided.\nUnit must include an accessible jack panel that provides at least 12 (TRS 3-wire), Â¼ phone jacks, two USB ports, and 1 Â¾ pass through. Panel face must be removable and does not impact the rooms acoustical performance.\nTotal rise from the host floor to the door opening must be no larger than 7 Â½ .\nSprinkler holes must be at least 3 in diameter.\nUnit must by supplied with standard carpet or carpet tile in both rooms.\nMust be able to provide empty utility boxes with pull wires for data, thermostats, and alarms.\nRoom must require no more than 120V, 15/20 AMP, or 60 Hz supply circuit.\nUnit must provide at least 2 duplex outlets and light/fan switches.\nUnit wall panels must be at least 4 thick in both rooms.\nUnit ceiling panels must be at least 6 thick in both rooms.\nBoth the control and exam room must have a minimum clear interior height of 83 for all features attached to the ceiling panels.\nLight switches must be at least 44 from the floor inside of the unit, in both rooms.\nOutlets must be at least 15 from the floor inside of the unit, in both rooms.\nMust include rubber mat as floors inside the booth at a height no greater than 10mm (3/8 ) height for wheelchair access.\nBooth doors must be at least 75 mm (2 7/8 ) thick.\nBooth doors mounted with heavy duty cam lift hinges.\nDoor sealing system must have at least a double magnetic gasket sealing system and flush sill seal design for an accurate acoustic seal.\nBoth rooms must have at least a 60 minimum turning radius for wheelchair access.\nPanels in the unit must have a Flame Spread rating of 3.\nPanels in the unit must have a Smoke Density Rating of 2.\nBoth the control and exam room must come with standard sprinkler penetrations for onsite installation.\nAll electrical in the unit must be Hospital Grade.\nUnit wall shells must be fabricated with cold rolled steel frames (14 ga) and steel outer surfaces (16 ga).\nFraming members on unit wall shell should not be spaced out any further than 610 mm (24 ) centers.\nUnit wall inner panels should be fabricated with cold rolled steel (22 ga) that includes holes no greater than 2.4 mm (3/32 ) diameter, where holes are staggered on 4 mm (5/32 ) centers.\nPanels must interlock and provide an acoustic seal that utilizes a minimum of two sets of closed cell acoustic rubber seals and at least two interlocking panel connectors.\n\nIMPLEMENTATION AND INSTALLATION\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation.\nAll materials required to assemble the audiology booth shall be provided by the contractor.\nThe contractor will deliver the audiology booth and accessories to the addresses below:\nCambridge VA Outpatient Clinic, 830 Chesapeake Drive, Cambridge, MD 21613-9408\nOne (1) Audiology Booth, Sloped Rubber Ramp\nAccessories\n\nTRAINING\nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\n\nDELIVERY\nThe contractor shall deliver necessary equipment to the Cambridge VA facility as required in the quantity specified above.\nThe contractor must deliver the audiology booth to the Cambridge facility with a small bed truck that has a lift because this location does not have a loading dock.\nThe contractor must give VAMHCS staff 3 weeks notice of shipment and delivery of the audiology booth and accessories.\nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. Installation can proceed 90 days after award of contract.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.\n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC).\n\nWARRANTY\nAt a minimum the audiology booth must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government.\nThe warranty shall begin upon completion of validation testing.\nWarranty shall include onsite repairs and over the phone support.\nContractor shall provide routine maintenance service program during warranty period.\nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nLINE-ITEM DESCRIPTION\n\nAUDIOLOGY BOOTH FOR BALTIMORE CBOC VAMC\n\nBRAND NAME OR EQUAL TO ECKEL IAW SOW\n\nB.3 PRICE/COST SCHEDULE\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nEA\n__________________\n__________________\n\nCL-123 PR Sing Wall Cont, Double Wall Exam Suite / 1001354\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001354\nLOCAL STOCK NUMBER: 1001354\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nLBR-Sound Room Relocation/Installation 1000033\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1000033\nLOCAL STOCK NUMBER: 1000033\n\n0003\n\n2.00\nEA\n__________________\n__________________\n\nEAO-A-003 Add-On Add - Wall Fascia Closure Angles 1001408\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001408\nLOCAL STOCK NUMBER: 1001408\n\n0004\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-004 Add-On Door - Window in Door 20\"W x 22\"H 1001416\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001416\nLOCAL STOCK NUMBER: 1001416\n\n0005\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-007 Add-Ons - Door - Magnetic Door Holder 1001418\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001418\nLOCAL STOCK NUMBER: 1001418\n\n0006\n\n2.00\nEA\n__________________\n__________________\n\nEAO-U-003 Add-On Utilities - Light Dimmer Switch 1001425\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001425\nLOCAL STOCK NUMBER: 1001425\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEAO-U-005 Add-On Util Sprinkler Hole Double Wall 1001427\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001427\nLOCAL STOCK NUMBER: 1001427\n\n0008\n\n1.00\nSE\n__________________\n__________________\n\nEAO-U-007 Add-On Utilities - HVAC Collars (2 Sets) 1001429\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001429\nLOCAL STOCK NUMBER: 1001429\n\n0009\n\n2.00\nBX\n__________________\n__________________\n\nEAO-U-002 Add-On Util Rough Ins (Box w. Pull wire) 1001424\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"\nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001424\nLOCAL STOCK NUMBER: 1001424\n\nGRAND TOTAL\n__________________","html":"THIS REQUEST FOR INFORMATION (RFI) - IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\n\nSEE ATTACHMENT FOR DETAILS:\n\n AUDIOLOGY BOOTH   BALTIMORE VAMC - CAMBRIDGE CBOC\n\n  BRAND NAME OR EQUAL TO ECKEL IAW STATEMENT OF WORK \n\n MUST PROVIDE AN AUTHORIZED DISTRIBUTOR LETTER IF YOU ARE NOT THE   MANUFACTURER AT THE TIME RFI WILL CLOSE TO QUALIFY FOR THIS SOLICITATION . \n\n MUST PROVIDE THE COUNTRY OF ORIGIN (COO) FOR EACH LINE ITEM  \n\nThis is a requirement for: \n\nU.S. Department of Veterans Affairs VA Medical Center (VAMC).\n\n\nDESCRIPTION: \n\nThe Baltimore CBOC VAMC requires the contractor to deliver within 90 days from contract award to the VA medical facility warehouse below during normal business hours from 8:00 a.m. to 3:30 p.m. (EST), Monday through Friday:\n\nDelivery to:\nU.S. Department of Veterans Affairs\nBaltimore VA Medical Center\nCambridge CBOC\nWAREHOUSE/ATTN: \n830 Chesapeake Drive\nCambridge, MD 21613\n\n\nDISCLAIMER:\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nNote: The contractor shall deliver required commodities (Please see attachments) no later than 90 days or less from date of award, unless otherwise directed by the Contracting Officer (CO). Commodities shall not be delivered to the Government site on Federal holidays or weekends unless directed by the CO. Delivery shall be made between the hours of 8:00 am and 3:30 pm of the delivery location, during normal workday business hours.\nThe U.S. Government is Performing Market Research to identify responsible sources who have the skills, experience, and knowledge required to successfully meet the requirements. Information received from Market Research will determine the best acquisition strategy and if responsible sources exist for competition, and/or a total Small Business Set-Aside. This is only for Market Research but may result in an invitation to an open discussion with the U.S. Government. This notice is not to be construed as a commitment by the U.S. Government. All information is to be submitted at no cost or obligation to the U.S. Government. \nAny information submitted by respondents to this notice is strictly voluntary. Propriety information or trade secrets should be clearly marked. Information received will not be returned. The U.S. Government reserves the right to reject, in whole or in part, any private sector input as a result of this Sources Sought notice/market survey. \nThe U.S. Government is not obligated to notify respondents of the results of this notice. All responses to this Sources Sought must be submitted to the point of contact listed herein. This does not constitute a commitment, implied or otherwise, that procurement will be accomplished and is not a request for proposal or invitation for bid. Responding to this notice in no manner guarantees a contract will be awarded. \n**Respondents to this source sought announcement capable of manufacturing these items should at a minimum provide the following information for U.S. Government review**\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\nIs your company considered small under the NAICS code identified under this RFI? \n\nAre you the manufacturer or distributor of the items being referenced above? \n\nWhat is the place of manufacturing for the requested items? 52.212-3(j)\n\nIf paragraph (j) of the provision is applicable, a written submission is required. Offerors must be registered in SAM at time of offer submission. MUST COMPLETE PLACE OF MANUFACTURER.\n\n(j) Place of manufacture. (The solicitation is predominantly for the acquisition of manufactured end products.) For statistical purposes only, the offeror shall indicate whether the place of manufacture of the end products it expects to provide in response to this solicitation is predominantly \n\n    (1) __ In the United States (Check this box if the total anticipated price of offered end products manufactured in the United States exceeds the total anticipated price of offered end products manufactured outside the United States); or\n          (2) __ Outside the United States.\n\nIf you are not a manufacturer. Company shall provide an authorized distributor or reseller letter from original equipment manufacturers (OEM) to qualify for this requirement.\n\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number and SIN number?\n\nIf you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract/SIN?\n\nMust provide Manufacture Name (OEM) & Manufacturer Part # (MPN).\n\nPlease provide general pricing for your products/solutions for market research purposes.\n\n Legal Business/Company Name (as it is indicated in https://sam.gov ).\n\n Unique Entity ID UEI (SAM) & DUNS Number.\n\n Warranty Information (Can be a separate attachment).\n\n Point of Contact Name, Telephone number and email address.\n\nMust provide the estimated delivery time frame after award. For Example: Within 60 days ARO, Within 90 days ARO. \n\nThe Government intends to award a Firm-Fixed Price (FFP) contract for this purchase. \nTo be considered for award, prospective quoters must be registered with the System for Award Management (SAM) website and complete representations and certifications at https://www.sam.gov . Prospective awardees MUST be registered with the System for Award Management (SAM) at http://www.sam.gov. PRIOR TO AWARD and through final payment and must complete the Online Representations and Certifications Application (ORCA) at http://www.sam.gov prior to award and through final payment. CONTRACT WILL NOT BE AWARDED UNTIL SAM REGISTRATION HAS BEEN COMPLETED. SDVOSB and VOSB socio-economic categories MUST be verified in the SBA Website, U.S. Small Business Administration: https://veterans.certify.sba.gov, at the time of receipt of quotes and at the time of award. \n\nResponses to this notice shall be submitted via email: Mohsin.Abbas2@va.gov.  No Telephone responses shall not be accepted. Responses must be received no later than Friday, Feb 28, 2025, by 2:00 PM (EST). \n\nResponses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SAM.GOV/Open Market or GSA eBuy.\n\n\nSTATEMENT OF WORK (SOW)\nAUDIOLOGY BOOTH\nVA MARYLAND HEALTH CARE SYSTEM\nBALTIMORE, MD\n\nPURPOSE:\nThe VA Maryland Health Care System is seeking to procure and install an audiology booth at the Cambridge VA Clinic. This new audiology booth will replace a nonfunctional audiology booth. The audiology booth will provide a soundproof suite for patients and employees to conduct hearing exams in an isolated area for precise results. The primary function of the audiology booth is to provide an isolated acoustical room to measure hearing acuity in patients. Isolated acoustic rooms are crucial to eliminating background noise to acquire a reliable diagnosis in patients. Audiology booth will include a rubber ramp for wheelchair access. Key criteria include system size, weight, and acoustic installation. \n\nSCOPE: \nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted. \nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities listed within the scope. \nThe contractor shall deliver the audiology booth to the Cambridge facility as specified below. \nThe assembly and validation of the system must be performed by a vendor service trained representative. \nThe contractor is responsible for identifying any missing parts or components not included in the order for the audiology booth to be successfully installed and validated to their full potential. \nThe contractor shall include accessories and consumables that have been detailed on the provided quotes. \nSALIENT CHARACTERISTICS: Please note, all items listed below must be technically equivalent to Eckel Noise Control Technologies Audiology Booth. \nOne CL-123 PR Sing Wall Cont, Double Wall Exam Suite \nManufacturer: Eckel Noise Control Technologies\nModel: CL-123 FP7 PRIME\nMust include an acoustically engineered independent ventilation system that is mounted external to the unit. \nUnit provides recessed incandescent lighting. \nUnit must have an acoustic door with cam -lift hinges, providing at least 914 mm x 2032 mm (36  x 80 ) clear opening. \nMust include a double glazed, safety glass window that is at least 6 mm (1/4 ) thick and at least 762 mm x 762 mm (30  x 30 ). \nUnit must be electrically serviced via a grounded cable, having a length of at least 20 feet. \nUnit floor must be acoustically isolated in both the control and exam room. \nUnit must have a noise reduction coefficient of 1.05, while having an absorption coefficient range of 0.79-1.10 when measuring the center frequency (Hz) between a range of 125-400 Hz. \nNoise reduction in a double wall room must be able to reduce the center frequency (Hz) of 2000Hz and 4000Hz to 100, 125Hz to 44, 250Hz to 62, 500Hz to 81, 1000Hz to 93, and 8000Hz to 95. Noise reduction measured from the outside to the inside. \nDoor size must be at least 36  W by 80 H clear opening. \nDoor handles must be a C-shape while providing a minimum clearance of 1 Â½  behind it. \nDoors cannot require more than 5psi constant pressure to open, once the magnetic seal is broken. \nDouble glazes acoustic windows for the doors on the booth, size options must include: 20  W by 22 H or 20  W by 60  H. \nUnit includes a standard fan exhaust and fan inlet silencers suspended to the ceiling. Silencers mist be capable of 10 to 12 full air exchanges per hour. Fans include a 6  or 8  diameter HVAC collar option. \nUnit must include two ventilation silencers built into the booth s ceilings, one supply and one exhaust provided. \nUnit must include an accessible jack panel that provides at least 12 (TRS 3-wire), Â¼  phone jacks, two USB ports, and 1 Â¾  pass through. Panel face must be removable and does not impact the rooms acoustical performance. \nTotal rise from the host floor to the door opening must be no larger than 7 Â½ . \nSprinkler holes must be at least 3  in diameter. \nUnit must by supplied with standard carpet or carpet tile in both rooms. \nMust be able to provide empty utility boxes with pull wires for data, thermostats, and alarms. \nRoom must require no more than 120V, 15/20 AMP, or 60 Hz supply circuit. \nUnit must provide at least 2 duplex outlets and light/fan switches. \nUnit wall panels must be at least 4  thick in both rooms. \nUnit ceiling panels must be at least 6  thick in both rooms.\nBoth the control and exam room must have a minimum clear interior height of 83  for all features attached to the ceiling panels. \nLight switches must be at least 44  from the floor inside of the unit, in both rooms. \nOutlets must be at least 15  from the floor inside of the unit, in both rooms. \nMust include rubber mat as floors inside the booth at a height no greater than 10mm (3/8 ) height for wheelchair access. \nBooth doors must be at least 75 mm (2 7/8 ) thick. \nBooth doors mounted with heavy duty cam lift hinges. \nDoor sealing system must have at least a double magnetic gasket sealing system and flush sill seal design for an accurate acoustic seal. \nBoth rooms must have at least a 60  minimum turning radius for wheelchair access.\nPanels in the unit must have a Flame Spread rating of 3.\nPanels in the unit must have a Smoke Density Rating of 2.\nBoth the control and exam room must come with standard sprinkler penetrations for onsite installation. \nAll electrical in the unit must be Hospital Grade. \nUnit wall shells must be fabricated with cold rolled steel frames (14 ga) and steel outer surfaces (16 ga). \nFraming members on unit wall shell should not be spaced out any further than 610 mm (24 ) centers. \nUnit wall inner panels should be fabricated with cold rolled steel (22 ga) that includes holes no greater than 2.4 mm (3/32 ) diameter, where holes are staggered on 4 mm (5/32 ) centers. \nPanels must interlock and provide an acoustic seal that utilizes a minimum of two sets of closed cell acoustic rubber seals and at least two interlocking panel connectors.\n\nIMPLEMENTATION AND INSTALLATION \nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation. \nAll materials required to assemble the audiology booth shall be provided by the contractor. \nThe contractor will deliver the audiology booth and accessories to the addresses below:\nCambridge VA Outpatient Clinic, 830 Chesapeake Drive, Cambridge, MD 21613-9408\nOne (1) Audiology Booth, Sloped Rubber Ramp\nAccessories\n\nTRAINING \nThe contractor shall provide onsite training for all VAMHCS staff that requires training.\n\nDELIVERY \nThe contractor shall deliver necessary equipment to the Cambridge VA facility as required in the quantity specified above. \nThe contractor must deliver the audiology booth to the Cambridge facility with a small bed truck that has a lift because this location does not have a loading dock. \nThe contractor must give VAMHCS staff 3 weeks  notice of shipment and delivery of the audiology booth and accessories.  \nThe contractor shall deliver equipment and all items required for installation only when the site is ready for installation to proceed. Installation can proceed 90 days after award of contract. \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMHCS facilities.  \n\nINSPECTION AND ACCEPTANCE\nThe contractor shall conduct a joint inspection with the COR upon delivery equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format. \n\nOPERATOR TRAINING \nOnsite education and training by a vendor service trained representative will be provided to VAMHCS clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the VAMHCS clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. The contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \nThe contractor must follow the VA Maryland Health Care Systems current COVID-19 guidance for entry to any medical center or Community Based Outpatient Clinic (CBOC). \n\nWARRANTY\nAt a minimum the audiology booth must include a 1-year warranty on all parts and labor at no cost to the Government. Additional years are highly recommended as added value to the government. \nThe warranty shall begin upon completion of validation testing. \nWarranty shall include onsite repairs and over the phone support. \nContractor shall provide routine maintenance service program during warranty period. \nAll repairs shall be performed by a vendor or contractor which has been certified by the vendor to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nLINE-ITEM DESCRIPTION\n\nAUDIOLOGY BOOTH FOR BALTIMORE CBOC VAMC\n\n BRAND NAME OR EQUAL TO ECKEL IAW SOW \n\nB.3 PRICE/COST SCHEDULE\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n1.00\nEA\n__________________\n__________________\n\nCL-123 PR Sing Wall Cont, Double Wall Exam Suite / 1001354\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001354\nLOCAL STOCK NUMBER: 1001354\n\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nLBR-Sound Room Relocation/Installation 1000033\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1000033\nLOCAL STOCK NUMBER: 1000033\n\n\n0003\n\n2.00\nEA\n__________________\n__________________\n\nEAO-A-003 Add-On Add - Wall Fascia Closure Angles 1001408\n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001408\nLOCAL STOCK NUMBER: 1001408\n\n\n0004\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-004 Add-On Door - Window in Door 20\"W x 22\"H 1001416 \n\"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001416\nLOCAL STOCK NUMBER: 1001416\n\n\n0005\n\n1.00\nEA\n__________________\n__________________\n\nEAO-D-007 Add-Ons - Door - Magnetic Door Holder 1001418\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001418\nLOCAL STOCK NUMBER: 1001418\n\n\n0006\n\n2.00\nEA\n__________________\n__________________\n\nEAO-U-003 Add-On Utilities - Light Dimmer Switch 1001425\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001425\nLOCAL STOCK NUMBER: 1001425\n\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEAO-U-005 Add-On Util Sprinkler Hole Double Wall 1001427\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001427\nLOCAL STOCK NUMBER: 1001427\n\n\n0008\n\n1.00\nSE\n__________________\n__________________\n\nEAO-U-007 Add-On Utilities - HVAC Collars (2 Sets) 1001429\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001429\nLOCAL STOCK NUMBER: 1001429\n\n\n0009\n\n2.00\nBX\n__________________\n__________________\n\nEAO-U-002 Add-On Util Rough Ins (Box w. Pull wire) 1001424\n \"BRAND NAME OR EQUAL TO ECKEL IAW SOW\"  \nPRINCIPAL NAICS CODE: 339112 - Surgical and Medical Instrument Manufacturing\nPRODUCT/SERVICE CODE: J065 - Maintenance, Repair, and Rebuilding of Equipment - Medical, Dental, and Veterinary Equipment and Supplies\nMANUFACTURER PART NUMBER (MPN): 1001424\nLOCAL STOCK NUMBER: 1001424\n\n\n\n\n\n\nGRAND TOTAL\n__________________","origin":"detail"},"contacts":[{"name":"Mohsin Abbas","role":"primary","email":"Mohsin.Abbas2@va.gov","phone":"202-745-8000 x54945","title":"Contract Specialist"}],"place_of_performance":{"zip":"21613","street":"Baltimore VAMC - Cambridge CBOC 830 Chesapeake Drive","street2":"Cambridge, MD 21613"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"1bb4deb8a9b645709fab1e1189679b4f","name":"36C24525Q0333.docx","kind":"file","mime_type":".docx","size_bytes":41565,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1bb4deb8a9b645709fab1e1189679b4f/download","mirrored":false},{"resource_id":"7e84f1f5f4c1485fb9735ad468abc708","name":"S02 - ATTACHMENT 1 - LINE-ITEM DESCRIPTION - AUDIOLOGY BOOTH - BRAND NAME OR EQUAL TO ECKEL - 02-21-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":151638,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7e84f1f5f4c1485fb9735ad468abc708/download","mirrored":false},{"resource_id":"365e7da126e54dc19b88c2e874c18d73","name":"S02 - ATTACHMENT 2 - STATEMENT OF WORK - AUDIOLOGY BOOTH FOR BALTIMORE VAMC - 02-21-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":150109,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/365e7da126e54dc19b88c2e874c18d73/download","mirrored":false},{"resource_id":"66f393b149824a3b901c7739a870db04","name":"S02 - ATATCHMENT 3 - 52.225-2 BUY AMERICAN CERTIFICATE - 02-21-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":105837,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/66f393b149824a3b901c7739a870db04/download","mirrored":false},{"resource_id":"2ad569c4325f4e6dac8cd453be83ec84","name":"S02 - ATTACHMENT 4 - DRAWING CAMBRIDGE CBOC.pdf","kind":"file","mime_type":".pdf","size_bytes":68747,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2ad569c4325f4e6dac8cd453be83ec84/download","mirrored":false},{"resource_id":"112a807dcace4e80aed18990f652dd2b","name":"S02 - ATTACHMENT 5 - LAYOUT AND PLAN - VA-Cambridge.24P197-D1 CL-123 FP7.pdf","kind":"file","mime_type":".pdf","size_bytes":798716,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/112a807dcace4e80aed18990f652dd2b/download","mirrored":false},{"resource_id":"4e90eac2cdd1409b938fdbd0f0b8c7ec","name":"S02 - ATTACHMENT 6 - VAAR 852.212-71 - GRAY AND COUNTERFEITS ITEMS - Gray Market Prevention Language - 02-21-2025.pdf","kind":"file","mime_type":".pdf","size_bytes":81377,"posted_at":"2025-02-21T20:15:56.564Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4e90eac2cdd1409b938fdbd0f0b8c7ec/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27001101","latest_notice_id":"352f21577e56484e9a1121550b56e448","title":"Intent to Sole Source - TELEMED ArtUs EXT-2H ultrasound system with RF module, two ultrasound transducers, and a ProbeFix Dynamic T probe holder","solicitation_number":"NOI-OLAO-CC-27-001101","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"339112","psc":"6515","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"75N98027Q00038SBPCANIA11810","latest_notice_id":"427cad0cab794e55b2ddb3fe92acc285","title":"Baxter/Hill-Rom Helux Pro Surgical Light System","solicitation_number":"75N98027Q00038SB_PCA-NIA-11810","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-08T19:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"339112","psc":"6515","set_aside":"SBA","state":"MD","county":"24003","county_name":"Anne Arundel County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":15,"indexable":false}