{"canonical":"https://sealedbidder.com/opportunities/36c24525q0287","key":"36C24525Q0287","url":"https://sealedbidder.com/opportunities/36c24525q0287","title":"6515--Dose Calibrator & Well Counter","solicitation_number":"36C24525Q0287","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-13T15:00:00Z","first_posted":"2025-02-05","last_posted":"2025-02-05","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334516","psc":"6515","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"22fa04e78c414d77bbe82bd5c2e68c5c","title":"6515--Dose Calibrator & Well Counter","solicitation_number":"36C24525Q0287","notice_type":"r","base_type":"r","posted":"2025-02-05","posted_at":"2025-02-05T18:25:56.117Z","due_at":"2025-02-13T15:00:00Z","due_date":"2025-02-13","cancelled":false,"archived":true,"archive_date":"2025-02-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/22fa04e78c414d77bbe82bd5c2e68c5c/view","enriched":true,"history":[{"index":3,"title":"6515--Dose Calibrator & Well Counter","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T18:25:56.117Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"22fa04e78c414d77bbe82bd5c2e68c5c","solicitation_number":"36C24525Q0287"}]}],"latest_notice_id":"22fa04e78c414d77bbe82bd5c2e68c5c","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-05","posted_at":"2025-02-05T18:25:56.117Z","created_at":"2025-02-05T18:25:53.895Z","modified_at":"2025-02-24T04:55:45.008Z","response_deadline":{"raw":"2025-02-13T10:00:00-05:00","utc":"2025-02-13T15:00:00Z","date":"2025-02-13","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/22fa04e78c414d77bbe82bd5c2e68c5c/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Dose Calibrator & Well Counter","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-23","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Dose Calibrator & Well Counter","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-05T18:25:56.117Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"22fa04e78c414d77bbe82bd5c2e68c5c","solicitation_number":"36C24525Q0287"}],"contacts":[{"name":"Michael Jones","role":"primary","email":"michael.jones16@va.gov","phone":"(202) 745-8000 Ext. 52485","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"22fa04e78c414d77bbe82bd5c2e68c5c","lineage_id":"22fa04e78c414d77bbe82bd5c2e68c5c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-23T03:40:57.692546845Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8fc510d5005f159ad6c79693c863b1f6233639809fc71363574532f2d1b17b14","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-23T03:40:57.692546845Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.\nTHIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. \nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.\nSOURCES SOUGHT DESCRIPTION\nThis is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide a Dose Calibrator & Well Counter for the Baltimore VA Medical Center.\n\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n2.00\nEA\n__________________\n__________________\n\nEPSON ROLL PRINTER \nLOCAL STOCK NUMBER: 5430-0058\n\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nWELL INSERT FOR DOSE CALIBRATOR CHAMBER \nLOCAL STOCK NUMBER: 7300-2004\n\n\n0003\n\n1.00\nEA\n__________________\n__________________\n\nVIAL SYRINGE/DIPPER. \nLOCAL STOCK NUMBER: 7300-2005\n\n\n0004\n\n2.00\nEA\n__________________\n__________________\n\nSCREEN COVERS/PROTECTIVE AND REMOABLE. \nLOCAL STOCK NUMBER: 7900-0353\n\n\n0005\n\n2.00\nBX\n__________________\n__________________\n\nPAPER(12/ROLL) FOR EPSON ROLL PRINTER. \nLOCAL STOCK NUMBER: 9282-0009\n\n\n0006\n\n1.00\nEA\n__________________\n__________________\n\nCESIUM 137 ROD SOURCE (0.5cI) \nLOCAL STOCK NUMBER: 0975-137R\n\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEUROPIUM 152(0.5UcI) ROD SOURCE. \nLOCAL STOCK NUMBER: 0975-152R\n\n\n0008\n\n1.00\nEA\n__________________\n__________________\n\nCRC-55t DOSE CALIBRATOR (TOUCH SCREEN). \nLOCAL STOCK NUMBER: 5130-3234\n\n\n0009\n\n1.00\nEA\n__________________\n__________________\n\nCAPRAC-t TOUCH SCREEN WIPE TEST/WELL COUNTER. \nLOCAL STOCK NUMBER: 5430-3136\n\n\n0010\n\n1.00\nEA\n__________________\n__________________\n\nAUXILIARY SHIELD FOR PET 1 1/2\" LEAD, CAPRAC. \nLOCAL STOCK NUMBER: 5420-2137\n\n\n0011\n\n1.00\nBX\n__________________\n__________________\n\nTEST TUBES FOR SAMPLES. \nLOCAL STOCK NUMBER: 5420-0087\n\n\n0012\n\n1.00\nBX\n__________________\n__________________\n\nWIPE TEST SAMPLE WIPES WITH I.D. TAGS. \nLOCAL STOCK NUMBER: 5420-0086\n\n\n\n\n\n\nGRAND TOTAL\n__________________\n\n\n\nStatement of Work (SOW)\nScope of Work:\nThe vendor shall provide the following:\n        o Delivery of the CRC-55T Dose Calibrator and all associated components.\n        o Deliver of the CAPRAC-t Touch Screen wipe Test/Well Counter and all associated         components.\n\n\nDeliverables:\n\nEPSON roll printer - 2 each.\nWell insert for Dose Calibrator chamber - 1 each.\nVial Syringe/Dipper - 1 each.\nScreen covers/protective and removable- 2 each.\nPaper (12/roll) for Epson Roll Printer- 2 each.\nCesium 137(0.5uCi) rod source -1 each.\nEuropium 152(0.5 uCi) rod source -1 each.\nCRC-55tR dose calibrator (touch screen)   1 each.\nCAPRAC-t Touch Screen Wipe Test/Well Counter   1 each\nAuxiliary shield for PET 1 Â½  lead   1 each.\nTest Tubes for samples (100)   1 box.\nWipe test sample wipes with I.D. tags (500)   1 box.\n\nSalient Characteristics for the Dose Calibrator (CRC-55tR):\n\n1. Touchscreen Interface: Features an intuitive touchscreen for ease of operation and clear data presentation.\n\n\n2. Accuracy and Reliability: Designed for precise measurement of radiopharmaceutical doses with minimal drift.\n\n\n3. Compact Design: Space-saving form factor suitable for Nuclear Medicine department setups.\n\n\n4. Wide Range of Calibration: Supports a comprehensive range of radionuclides.\n\n\n5. Durability: Includes alcohol and break-resistant well insert for prolonged use and resilience.\n\n\n6. Accessories: Compatible with various accessories like vial/syringe dippers and screen protectors.\n\n\n7. Integrated Printing: Includes an EPSON roll printer for generating dose measurement records.\n\n\n8. Regulatory Compliance: Meets health physics standards for accurate dose measurement and safety.\n\n\nEnergy Range:\n\nMust be able to detect and measure a broad spectrum of energies, typically ranging from 15 keV to 3 MeV.\n\nShould include isotopes commonly used in nuclear medicine, such as Tc-99m, I-131, F-18, Ga-68, and others.\n\n\nMeasurement Range:\n\nShould be capable of measuring activities ranging from 1 ÂµCi to 20 Ci or higher, depending on clinical needs.\n\n\nAccuracy:\n\nAccuracy within Â±2-5% across its entire measurement range, as required by regulatory guidelines.\n\n\nReproducibility:\n\nCoefficient of variation (precision) should typically be less than 1% for repeated measurements under the same conditions.\n\n\nDisplay:\n\nDigital LCD or LED readout, displaying activity in units like:\n\nMBq (Mega Becquerels)\n\nÂµCi or mCi (Micro or Milli Curie)\n\n\n\nIonization Chamber:\n\nType: Sealed, pressurized gas-filled chamber.\n\nPressure: Typically filled with argon gas at 15-20 atmospheres.\n\nChamber material: Typically aluminum or plastic housing with internal lead shielding.\n\n\nCalibration Factors:\n\nShould support pre-programmed isotope-specific calibration factors.\n\nAllow user-defined settings for custom isotopes.\n\n\nResponse Time:\n\nFast response, generally within 1-3 seconds.\n\n\nStability\n\nLong-term stability with drift correction, typically needing annual recalibration or quality control.\n\n\nQuality Control:\n\nIncludes self-diagnostic checks for:\n\nConstancy\n\nLinearity\n\nGeometry dependency\n\n\nQuality control standards must meet NRC, USP 825, or local equivalent regulatory requirements.\n\n\nSoftware/Interface:\n\nMay include connectivity via USB, Ethernet, or wireless for data storage and reporting.\n\nCompatible with PACS or EMR integration for documentation.\n\n\nPower Supply\n\nOperates on 120-240V AC or includes a battery backup for portability.\n\n\nDimensions and Weight:\n\nCompact size for placement in hot labs.\n\nWeight: 10-30 lbs depending on shielding and housing.\n\n\n\nAccessories:\n\nLead shielding rings or liners for high-energy isotopes.\n\nQuality control phantoms for accuracy testing.\n\nThe Capintec CAPRAC (Captus Radioactive Assay Calibrator) is a specialized gamma counter primarily used in nuclear medicine for wipe tests, bioassays, and other radioactivity measurements. Below are the general technical specifications for the CAPRAC systems:\n\n\nDetector:\n\nType: Sodium Iodide (NaI) scintillation detector\n\nSize: Typically 1  x 1  or similar for high sensitivity.\n\nEnergy Range: 15 keV to 2 MeV.\n\nShielding: 1/8-inch lead shielding around the detector to reduce background interference.\n\n\nSensitivity and Accuracy:\n\nCount Rate: Capable of high-sensitivity measurements.\n\nAccuracy: Â±1% for reproducibility of results.\n\nEfficiency: Designed to detect low levels of radiation with high precision, typically suitable for wipe tests with extremely low activity.\n\n\nEnergy Calibration:\n\nMulti-channel analyzer (MCA) included for energy-specific measurements.\n\nCalibrated for isotopes like:\n\nTc-99m\n\nI-123\n\nI-131\n\nF-18\n\nCs-137\n\n\nCustomizable isotope libraries for specific applications.\n\nDisplay and Software\n\nDisplay: Digital touchscreen interface (varies by model).\n\nData Output: Integrated software allows data to be saved, exported, and printed.\n\nReports: Can generate detailed reports for regulatory compliance.\n\nConnectivity: USB, Ethernet, or wireless options for data transfer to PACS or EMR systems.\n\nUser Programs: Allows for customizable QC protocols.\n\n\nQuality Control\n\nSelf-check protocols for:\n\nConstancy\n\nSensitivity\n\nEnergy Calibration\n\nSupports adherence to NRC, USP 825, and similar international regulatory guidelines.\n\n\nCounting Modes\n\nWipe Test Mode:\n\nDetects contamination and verifies cleaning protocols.\n\nProvides readings in counts per minute (CPM) or disintegrations per minute (DPM).\n\n\n\nBioassay Mode:\n\nMeasures small quantities of activity in biological samples.\n\n\nCustom Counting:\n\nAllows for user-defined assays or measurements.\n\nPower Supply:\n\nVoltage: Operates on standard 110-240V AC power.\n\nBattery backup option for uninterrupted operation.\n\n\nDimensions and Weight:\n\nSize: Compact design for bench-top placement.\n\nWeight: ~20-30 lbs depending on the shielding and detector configuration.\n\n\nRegulatory Compliance\n\nDesigned to comply with:\n\nNRC regulations for radiation detection.\n\nUSP 825 for radiopharmaceutical handling.\n\nCAP standards for laboratory operations.\n\n\nApplications:\n\nRoutine wipe testing for contamination monitoring.\n\nBioassay measurements for internal dose assessments.\n\nRoutine nuclear medicine quality control.\n\n\n\nSalient Characteristics for the Countertop Well Counter (CAPRAC-t):\n\n1. Touchscreen Interface: Features a modern touchscreen for user-friendly operation.\n\n\n2. High Sensitivity: Provides accurate wipe test and sample counting results.\n\n\n3. Auxiliary Shielding: Includes optional PET auxiliary shielding with 1 Â½-inch lead for enhanced radiation protection.\n\n\n4. Sample Testing: Accommodates a variety of test tubes and wipe test samples.\n\n\n5. Durability: Comes with removable screen protectors to ensure longevity.\n\n\n6. Compact Size: Designed for efficient countertop use in a hot lab or controlled space.\n\n\n7. Integrated Printing Capability: Compatible with roll printers for documentation of test results.\n\n\n8. Regulatory Compliance: Ensures adherence to NHPP standards for contamination testing and environmental safety.\n\nPlace of Performance: \n\nDepartment of Veterans Affairs\nBaltimore VA Medical Center\n10 N. Greene St.\nBaltimore MD 21201\n------------------------------------------------------------------------------------------------------------------------------ \nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. \nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.\n(2) Is your company considered small under the NAICS code identified under this RFI?\n(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n(4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n(7) Please provide general pricing for your products/solutions for market research purposes.\n(8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?\n*** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items\" meet all required salient characteristics.\nResponses to this notice shall be submitted via email to Michael.Jones16@va.gov.  Telephone responses shall not be accepted. Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.  If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","text":"Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.\nTHIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.\nSOURCES SOUGHT DESCRIPTION\nThis is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide a Dose Calibrator & Well Counter for the Baltimore VA Medical Center.\n\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n2.00\nEA\n__________________\n__________________\n\nEPSON ROLL PRINTER\nLOCAL STOCK NUMBER: 5430-0058\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nWELL INSERT FOR DOSE CALIBRATOR CHAMBER\nLOCAL STOCK NUMBER: 7300-2004\n\n0003\n\n1.00\nEA\n__________________\n__________________\n\nVIAL SYRINGE/DIPPER.\nLOCAL STOCK NUMBER: 7300-2005\n\n0004\n\n2.00\nEA\n__________________\n__________________\n\nSCREEN COVERS/PROTECTIVE AND REMOABLE.\nLOCAL STOCK NUMBER: 7900-0353\n\n0005\n\n2.00\nBX\n__________________\n__________________\n\nPAPER(12/ROLL) FOR EPSON ROLL PRINTER.\nLOCAL STOCK NUMBER: 9282-0009\n\n0006\n\n1.00\nEA\n__________________\n__________________\n\nCESIUM 137 ROD SOURCE (0.5cI)\nLOCAL STOCK NUMBER: 0975-137R\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEUROPIUM 152(0.5UcI) ROD SOURCE.\nLOCAL STOCK NUMBER: 0975-152R\n\n0008\n\n1.00\nEA\n__________________\n__________________\n\nCRC-55t DOSE CALIBRATOR (TOUCH SCREEN).\nLOCAL STOCK NUMBER: 5130-3234\n\n0009\n\n1.00\nEA\n__________________\n__________________\n\nCAPRAC-t TOUCH SCREEN WIPE TEST/WELL COUNTER.\nLOCAL STOCK NUMBER: 5430-3136\n\n0010\n\n1.00\nEA\n__________________\n__________________\n\nAUXILIARY SHIELD FOR PET 1 1/2\" LEAD, CAPRAC.\nLOCAL STOCK NUMBER: 5420-2137\n\n0011\n\n1.00\nBX\n__________________\n__________________\n\nTEST TUBES FOR SAMPLES.\nLOCAL STOCK NUMBER: 5420-0087\n\n0012\n\n1.00\nBX\n__________________\n__________________\n\nWIPE TEST SAMPLE WIPES WITH I.D. TAGS.\nLOCAL STOCK NUMBER: 5420-0086\n\nGRAND TOTAL\n__________________\n\nStatement of Work (SOW)\nScope of Work:\nThe vendor shall provide the following:\no Delivery of the CRC-55T Dose Calibrator and all associated components.\no Deliver of the CAPRAC-t Touch Screen wipe Test/Well Counter and all associated components.\n\nDeliverables:\n\nEPSON roll printer - 2 each.\nWell insert for Dose Calibrator chamber - 1 each.\nVial Syringe/Dipper - 1 each.\nScreen covers/protective and removable- 2 each.\nPaper (12/roll) for Epson Roll Printer- 2 each.\nCesium 137(0.5uCi) rod source -1 each.\nEuropium 152(0.5 uCi) rod source -1 each.\nCRC-55tR dose calibrator (touch screen) 1 each.\nCAPRAC-t Touch Screen Wipe Test/Well Counter 1 each\nAuxiliary shield for PET 1 Â½ lead 1 each.\nTest Tubes for samples (100) 1 box.\nWipe test sample wipes with I.D. tags (500) 1 box.\n\nSalient Characteristics for the Dose Calibrator (CRC-55tR):\n\n1. Touchscreen Interface: Features an intuitive touchscreen for ease of operation and clear data presentation.\n\n2. Accuracy and Reliability: Designed for precise measurement of radiopharmaceutical doses with minimal drift.\n\n3. Compact Design: Space-saving form factor suitable for Nuclear Medicine department setups.\n\n4. Wide Range of Calibration: Supports a comprehensive range of radionuclides.\n\n5. Durability: Includes alcohol and break-resistant well insert for prolonged use and resilience.\n\n6. Accessories: Compatible with various accessories like vial/syringe dippers and screen protectors.\n\n7. Integrated Printing: Includes an EPSON roll printer for generating dose measurement records.\n\n8. Regulatory Compliance: Meets health physics standards for accurate dose measurement and safety.\n\nEnergy Range:\n\nMust be able to detect and measure a broad spectrum of energies, typically ranging from 15 keV to 3 MeV.\n\nShould include isotopes commonly used in nuclear medicine, such as Tc-99m, I-131, F-18, Ga-68, and others.\n\nMeasurement Range:\n\nShould be capable of measuring activities ranging from 1 ÂµCi to 20 Ci or higher, depending on clinical needs.\n\nAccuracy:\n\nAccuracy within Â±2-5% across its entire measurement range, as required by regulatory guidelines.\n\nReproducibility:\n\nCoefficient of variation (precision) should typically be less than 1% for repeated measurements under the same conditions.\n\nDisplay:\n\nDigital LCD or LED readout, displaying activity in units like:\n\nMBq (Mega Becquerels)\n\nÂµCi or mCi (Micro or Milli Curie)\n\nIonization Chamber:\n\nType: Sealed, pressurized gas-filled chamber.\n\nPressure: Typically filled with argon gas at 15-20 atmospheres.\n\nChamber material: Typically aluminum or plastic housing with internal lead shielding.\n\nCalibration Factors:\n\nShould support pre-programmed isotope-specific calibration factors.\n\nAllow user-defined settings for custom isotopes.\n\nResponse Time:\n\nFast response, generally within 1-3 seconds.\n\nStability\n\nLong-term stability with drift correction, typically needing annual recalibration or quality control.\n\nQuality Control:\n\nIncludes self-diagnostic checks for:\n\nConstancy\n\nLinearity\n\nGeometry dependency\n\nQuality control standards must meet NRC, USP 825, or local equivalent regulatory requirements.\n\nSoftware/Interface:\n\nMay include connectivity via USB, Ethernet, or wireless for data storage and reporting.\n\nCompatible with PACS or EMR integration for documentation.\n\nPower Supply\n\nOperates on 120-240V AC or includes a battery backup for portability.\n\nDimensions and Weight:\n\nCompact size for placement in hot labs.\n\nWeight: 10-30 lbs depending on shielding and housing.\n\nAccessories:\n\nLead shielding rings or liners for high-energy isotopes.\n\nQuality control phantoms for accuracy testing.\n\nThe Capintec CAPRAC (Captus Radioactive Assay Calibrator) is a specialized gamma counter primarily used in nuclear medicine for wipe tests, bioassays, and other radioactivity measurements. Below are the general technical specifications for the CAPRAC systems:\n\nDetector:\n\nType: Sodium Iodide (NaI) scintillation detector\n\nSize: Typically 1 x 1 or similar for high sensitivity.\n\nEnergy Range: 15 keV to 2 MeV.\n\nShielding: 1/8-inch lead shielding around the detector to reduce background interference.\n\nSensitivity and Accuracy:\n\nCount Rate: Capable of high-sensitivity measurements.\n\nAccuracy: Â±1% for reproducibility of results.\n\nEfficiency: Designed to detect low levels of radiation with high precision, typically suitable for wipe tests with extremely low activity.\n\nEnergy Calibration:\n\nMulti-channel analyzer (MCA) included for energy-specific measurements.\n\nCalibrated for isotopes like:\n\nTc-99m\n\nI-123\n\nI-131\n\nF-18\n\nCs-137\n\nCustomizable isotope libraries for specific applications.\n\nDisplay and Software\n\nDisplay: Digital touchscreen interface (varies by model).\n\nData Output: Integrated software allows data to be saved, exported, and printed.\n\nReports: Can generate detailed reports for regulatory compliance.\n\nConnectivity: USB, Ethernet, or wireless options for data transfer to PACS or EMR systems.\n\nUser Programs: Allows for customizable QC protocols.\n\nQuality Control\n\nSelf-check protocols for:\n\nConstancy\n\nSensitivity\n\nEnergy Calibration\n\nSupports adherence to NRC, USP 825, and similar international regulatory guidelines.\n\nCounting Modes\n\nWipe Test Mode:\n\nDetects contamination and verifies cleaning protocols.\n\nProvides readings in counts per minute (CPM) or disintegrations per minute (DPM).\n\nBioassay Mode:\n\nMeasures small quantities of activity in biological samples.\n\nCustom Counting:\n\nAllows for user-defined assays or measurements.\n\nPower Supply:\n\nVoltage: Operates on standard 110-240V AC power.\n\nBattery backup option for uninterrupted operation.\n\nDimensions and Weight:\n\nSize: Compact design for bench-top placement.\n\nWeight: ~20-30 lbs depending on the shielding and detector configuration.\n\nRegulatory Compliance\n\nDesigned to comply with:\n\nNRC regulations for radiation detection.\n\nUSP 825 for radiopharmaceutical handling.\n\nCAP standards for laboratory operations.\n\nApplications:\n\nRoutine wipe testing for contamination monitoring.\n\nBioassay measurements for internal dose assessments.\n\nRoutine nuclear medicine quality control.\n\nSalient Characteristics for the Countertop Well Counter (CAPRAC-t):\n\n1. Touchscreen Interface: Features a modern touchscreen for user-friendly operation.\n\n2. High Sensitivity: Provides accurate wipe test and sample counting results.\n\n3. Auxiliary Shielding: Includes optional PET auxiliary shielding with 1 Â½-inch lead for enhanced radiation protection.\n\n4. Sample Testing: Accommodates a variety of test tubes and wipe test samples.\n\n5. Durability: Comes with removable screen protectors to ensure longevity.\n\n6. Compact Size: Designed for efficient countertop use in a hot lab or controlled space.\n\n7. Integrated Printing Capability: Compatible with roll printers for documentation of test results.\n\n8. Regulatory Compliance: Ensures adherence to NHPP standards for contamination testing and environmental safety.\n\nPlace of Performance:\n\nDepartment of Veterans Affairs\nBaltimore VA Medical Center\n10 N. Greene St.\nBaltimore MD 21201\n------------------------------------------------------------------------------------------------------------------------------\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below.\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.\n(2) Is your company considered small under the NAICS code identified under this RFI?\n(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n(4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n(7) Please provide general pricing for your products/solutions for market research purposes.\n(8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?\n*** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items\" meet all required salient characteristics.\nResponses to this notice shall be submitted via email to Michael.Jones16@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0287","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs Baltimore VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N. Greene St."},"product_service_code":"6515"}],"due_at":"2025-02-13T15:00:00Z","due_date":"2025-02-13","closes_at":"2025-02-13T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-23T04:29:26.141449Z","principal_notice_id":"22fa04e78c414d77bbe82bd5c2e68c5c","description":{"text":"Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.\nTHIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.\nSOURCES SOUGHT DESCRIPTION\nThis is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide a Dose Calibrator & Well Counter for the Baltimore VA Medical Center.\n\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n2.00\nEA\n__________________\n__________________\n\nEPSON ROLL PRINTER\nLOCAL STOCK NUMBER: 5430-0058\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nWELL INSERT FOR DOSE CALIBRATOR CHAMBER\nLOCAL STOCK NUMBER: 7300-2004\n\n0003\n\n1.00\nEA\n__________________\n__________________\n\nVIAL SYRINGE/DIPPER.\nLOCAL STOCK NUMBER: 7300-2005\n\n0004\n\n2.00\nEA\n__________________\n__________________\n\nSCREEN COVERS/PROTECTIVE AND REMOABLE.\nLOCAL STOCK NUMBER: 7900-0353\n\n0005\n\n2.00\nBX\n__________________\n__________________\n\nPAPER(12/ROLL) FOR EPSON ROLL PRINTER.\nLOCAL STOCK NUMBER: 9282-0009\n\n0006\n\n1.00\nEA\n__________________\n__________________\n\nCESIUM 137 ROD SOURCE (0.5cI)\nLOCAL STOCK NUMBER: 0975-137R\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEUROPIUM 152(0.5UcI) ROD SOURCE.\nLOCAL STOCK NUMBER: 0975-152R\n\n0008\n\n1.00\nEA\n__________________\n__________________\n\nCRC-55t DOSE CALIBRATOR (TOUCH SCREEN).\nLOCAL STOCK NUMBER: 5130-3234\n\n0009\n\n1.00\nEA\n__________________\n__________________\n\nCAPRAC-t TOUCH SCREEN WIPE TEST/WELL COUNTER.\nLOCAL STOCK NUMBER: 5430-3136\n\n0010\n\n1.00\nEA\n__________________\n__________________\n\nAUXILIARY SHIELD FOR PET 1 1/2\" LEAD, CAPRAC.\nLOCAL STOCK NUMBER: 5420-2137\n\n0011\n\n1.00\nBX\n__________________\n__________________\n\nTEST TUBES FOR SAMPLES.\nLOCAL STOCK NUMBER: 5420-0087\n\n0012\n\n1.00\nBX\n__________________\n__________________\n\nWIPE TEST SAMPLE WIPES WITH I.D. TAGS.\nLOCAL STOCK NUMBER: 5420-0086\n\nGRAND TOTAL\n__________________\n\nStatement of Work (SOW)\nScope of Work:\nThe vendor shall provide the following:\no Delivery of the CRC-55T Dose Calibrator and all associated components.\no Deliver of the CAPRAC-t Touch Screen wipe Test/Well Counter and all associated components.\n\nDeliverables:\n\nEPSON roll printer - 2 each.\nWell insert for Dose Calibrator chamber - 1 each.\nVial Syringe/Dipper - 1 each.\nScreen covers/protective and removable- 2 each.\nPaper (12/roll) for Epson Roll Printer- 2 each.\nCesium 137(0.5uCi) rod source -1 each.\nEuropium 152(0.5 uCi) rod source -1 each.\nCRC-55tR dose calibrator (touch screen) 1 each.\nCAPRAC-t Touch Screen Wipe Test/Well Counter 1 each\nAuxiliary shield for PET 1 Â½ lead 1 each.\nTest Tubes for samples (100) 1 box.\nWipe test sample wipes with I.D. tags (500) 1 box.\n\nSalient Characteristics for the Dose Calibrator (CRC-55tR):\n\n1. Touchscreen Interface: Features an intuitive touchscreen for ease of operation and clear data presentation.\n\n2. Accuracy and Reliability: Designed for precise measurement of radiopharmaceutical doses with minimal drift.\n\n3. Compact Design: Space-saving form factor suitable for Nuclear Medicine department setups.\n\n4. Wide Range of Calibration: Supports a comprehensive range of radionuclides.\n\n5. Durability: Includes alcohol and break-resistant well insert for prolonged use and resilience.\n\n6. Accessories: Compatible with various accessories like vial/syringe dippers and screen protectors.\n\n7. Integrated Printing: Includes an EPSON roll printer for generating dose measurement records.\n\n8. Regulatory Compliance: Meets health physics standards for accurate dose measurement and safety.\n\nEnergy Range:\n\nMust be able to detect and measure a broad spectrum of energies, typically ranging from 15 keV to 3 MeV.\n\nShould include isotopes commonly used in nuclear medicine, such as Tc-99m, I-131, F-18, Ga-68, and others.\n\nMeasurement Range:\n\nShould be capable of measuring activities ranging from 1 ÂµCi to 20 Ci or higher, depending on clinical needs.\n\nAccuracy:\n\nAccuracy within Â±2-5% across its entire measurement range, as required by regulatory guidelines.\n\nReproducibility:\n\nCoefficient of variation (precision) should typically be less than 1% for repeated measurements under the same conditions.\n\nDisplay:\n\nDigital LCD or LED readout, displaying activity in units like:\n\nMBq (Mega Becquerels)\n\nÂµCi or mCi (Micro or Milli Curie)\n\nIonization Chamber:\n\nType: Sealed, pressurized gas-filled chamber.\n\nPressure: Typically filled with argon gas at 15-20 atmospheres.\n\nChamber material: Typically aluminum or plastic housing with internal lead shielding.\n\nCalibration Factors:\n\nShould support pre-programmed isotope-specific calibration factors.\n\nAllow user-defined settings for custom isotopes.\n\nResponse Time:\n\nFast response, generally within 1-3 seconds.\n\nStability\n\nLong-term stability with drift correction, typically needing annual recalibration or quality control.\n\nQuality Control:\n\nIncludes self-diagnostic checks for:\n\nConstancy\n\nLinearity\n\nGeometry dependency\n\nQuality control standards must meet NRC, USP 825, or local equivalent regulatory requirements.\n\nSoftware/Interface:\n\nMay include connectivity via USB, Ethernet, or wireless for data storage and reporting.\n\nCompatible with PACS or EMR integration for documentation.\n\nPower Supply\n\nOperates on 120-240V AC or includes a battery backup for portability.\n\nDimensions and Weight:\n\nCompact size for placement in hot labs.\n\nWeight: 10-30 lbs depending on shielding and housing.\n\nAccessories:\n\nLead shielding rings or liners for high-energy isotopes.\n\nQuality control phantoms for accuracy testing.\n\nThe Capintec CAPRAC (Captus Radioactive Assay Calibrator) is a specialized gamma counter primarily used in nuclear medicine for wipe tests, bioassays, and other radioactivity measurements. Below are the general technical specifications for the CAPRAC systems:\n\nDetector:\n\nType: Sodium Iodide (NaI) scintillation detector\n\nSize: Typically 1 x 1 or similar for high sensitivity.\n\nEnergy Range: 15 keV to 2 MeV.\n\nShielding: 1/8-inch lead shielding around the detector to reduce background interference.\n\nSensitivity and Accuracy:\n\nCount Rate: Capable of high-sensitivity measurements.\n\nAccuracy: Â±1% for reproducibility of results.\n\nEfficiency: Designed to detect low levels of radiation with high precision, typically suitable for wipe tests with extremely low activity.\n\nEnergy Calibration:\n\nMulti-channel analyzer (MCA) included for energy-specific measurements.\n\nCalibrated for isotopes like:\n\nTc-99m\n\nI-123\n\nI-131\n\nF-18\n\nCs-137\n\nCustomizable isotope libraries for specific applications.\n\nDisplay and Software\n\nDisplay: Digital touchscreen interface (varies by model).\n\nData Output: Integrated software allows data to be saved, exported, and printed.\n\nReports: Can generate detailed reports for regulatory compliance.\n\nConnectivity: USB, Ethernet, or wireless options for data transfer to PACS or EMR systems.\n\nUser Programs: Allows for customizable QC protocols.\n\nQuality Control\n\nSelf-check protocols for:\n\nConstancy\n\nSensitivity\n\nEnergy Calibration\n\nSupports adherence to NRC, USP 825, and similar international regulatory guidelines.\n\nCounting Modes\n\nWipe Test Mode:\n\nDetects contamination and verifies cleaning protocols.\n\nProvides readings in counts per minute (CPM) or disintegrations per minute (DPM).\n\nBioassay Mode:\n\nMeasures small quantities of activity in biological samples.\n\nCustom Counting:\n\nAllows for user-defined assays or measurements.\n\nPower Supply:\n\nVoltage: Operates on standard 110-240V AC power.\n\nBattery backup option for uninterrupted operation.\n\nDimensions and Weight:\n\nSize: Compact design for bench-top placement.\n\nWeight: ~20-30 lbs depending on the shielding and detector configuration.\n\nRegulatory Compliance\n\nDesigned to comply with:\n\nNRC regulations for radiation detection.\n\nUSP 825 for radiopharmaceutical handling.\n\nCAP standards for laboratory operations.\n\nApplications:\n\nRoutine wipe testing for contamination monitoring.\n\nBioassay measurements for internal dose assessments.\n\nRoutine nuclear medicine quality control.\n\nSalient Characteristics for the Countertop Well Counter (CAPRAC-t):\n\n1. Touchscreen Interface: Features a modern touchscreen for user-friendly operation.\n\n2. High Sensitivity: Provides accurate wipe test and sample counting results.\n\n3. Auxiliary Shielding: Includes optional PET auxiliary shielding with 1 Â½-inch lead for enhanced radiation protection.\n\n4. Sample Testing: Accommodates a variety of test tubes and wipe test samples.\n\n5. Durability: Comes with removable screen protectors to ensure longevity.\n\n6. Compact Size: Designed for efficient countertop use in a hot lab or controlled space.\n\n7. Integrated Printing Capability: Compatible with roll printers for documentation of test results.\n\n8. Regulatory Compliance: Ensures adherence to NHPP standards for contamination testing and environmental safety.\n\nPlace of Performance:\n\nDepartment of Veterans Affairs\nBaltimore VA Medical Center\n10 N. Greene St.\nBaltimore MD 21201\n------------------------------------------------------------------------------------------------------------------------------\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below.\nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.\n(2) Is your company considered small under the NAICS code identified under this RFI?\n(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n(4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n(7) Please provide general pricing for your products/solutions for market research purposes.\n(8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?\n*** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items\" meet all required salient characteristics.\nResponses to this notice shall be submitted via email to Michael.Jones16@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","html":"Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.\nTHIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. \nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.\nSOURCES SOUGHT DESCRIPTION\nThis is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide a Dose Calibrator & Well Counter for the Baltimore VA Medical Center.\n\nITEM INFORMATION\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\n\n2.00\nEA\n__________________\n__________________\n\nEPSON ROLL PRINTER \nLOCAL STOCK NUMBER: 5430-0058\n\n\n0002\n\n1.00\nEA\n__________________\n__________________\n\nWELL INSERT FOR DOSE CALIBRATOR CHAMBER \nLOCAL STOCK NUMBER: 7300-2004\n\n\n0003\n\n1.00\nEA\n__________________\n__________________\n\nVIAL SYRINGE/DIPPER. \nLOCAL STOCK NUMBER: 7300-2005\n\n\n0004\n\n2.00\nEA\n__________________\n__________________\n\nSCREEN COVERS/PROTECTIVE AND REMOABLE. \nLOCAL STOCK NUMBER: 7900-0353\n\n\n0005\n\n2.00\nBX\n__________________\n__________________\n\nPAPER(12/ROLL) FOR EPSON ROLL PRINTER. \nLOCAL STOCK NUMBER: 9282-0009\n\n\n0006\n\n1.00\nEA\n__________________\n__________________\n\nCESIUM 137 ROD SOURCE (0.5cI) \nLOCAL STOCK NUMBER: 0975-137R\n\n\n0007\n\n1.00\nEA\n__________________\n__________________\n\nEUROPIUM 152(0.5UcI) ROD SOURCE. \nLOCAL STOCK NUMBER: 0975-152R\n\n\n0008\n\n1.00\nEA\n__________________\n__________________\n\nCRC-55t DOSE CALIBRATOR (TOUCH SCREEN). \nLOCAL STOCK NUMBER: 5130-3234\n\n\n0009\n\n1.00\nEA\n__________________\n__________________\n\nCAPRAC-t TOUCH SCREEN WIPE TEST/WELL COUNTER. \nLOCAL STOCK NUMBER: 5430-3136\n\n\n0010\n\n1.00\nEA\n__________________\n__________________\n\nAUXILIARY SHIELD FOR PET 1 1/2\" LEAD, CAPRAC. \nLOCAL STOCK NUMBER: 5420-2137\n\n\n0011\n\n1.00\nBX\n__________________\n__________________\n\nTEST TUBES FOR SAMPLES. \nLOCAL STOCK NUMBER: 5420-0087\n\n\n0012\n\n1.00\nBX\n__________________\n__________________\n\nWIPE TEST SAMPLE WIPES WITH I.D. TAGS. \nLOCAL STOCK NUMBER: 5420-0086\n\n\n\n\n\n\nGRAND TOTAL\n__________________\n\n\n\nStatement of Work (SOW)\nScope of Work:\nThe vendor shall provide the following:\n        o Delivery of the CRC-55T Dose Calibrator and all associated components.\n        o Deliver of the CAPRAC-t Touch Screen wipe Test/Well Counter and all associated         components.\n\n\nDeliverables:\n\nEPSON roll printer - 2 each.\nWell insert for Dose Calibrator chamber - 1 each.\nVial Syringe/Dipper - 1 each.\nScreen covers/protective and removable- 2 each.\nPaper (12/roll) for Epson Roll Printer- 2 each.\nCesium 137(0.5uCi) rod source -1 each.\nEuropium 152(0.5 uCi) rod source -1 each.\nCRC-55tR dose calibrator (touch screen)   1 each.\nCAPRAC-t Touch Screen Wipe Test/Well Counter   1 each\nAuxiliary shield for PET 1 Â½  lead   1 each.\nTest Tubes for samples (100)   1 box.\nWipe test sample wipes with I.D. tags (500)   1 box.\n\nSalient Characteristics for the Dose Calibrator (CRC-55tR):\n\n1. Touchscreen Interface: Features an intuitive touchscreen for ease of operation and clear data presentation.\n\n\n2. Accuracy and Reliability: Designed for precise measurement of radiopharmaceutical doses with minimal drift.\n\n\n3. Compact Design: Space-saving form factor suitable for Nuclear Medicine department setups.\n\n\n4. Wide Range of Calibration: Supports a comprehensive range of radionuclides.\n\n\n5. Durability: Includes alcohol and break-resistant well insert for prolonged use and resilience.\n\n\n6. Accessories: Compatible with various accessories like vial/syringe dippers and screen protectors.\n\n\n7. Integrated Printing: Includes an EPSON roll printer for generating dose measurement records.\n\n\n8. Regulatory Compliance: Meets health physics standards for accurate dose measurement and safety.\n\n\nEnergy Range:\n\nMust be able to detect and measure a broad spectrum of energies, typically ranging from 15 keV to 3 MeV.\n\nShould include isotopes commonly used in nuclear medicine, such as Tc-99m, I-131, F-18, Ga-68, and others.\n\n\nMeasurement Range:\n\nShould be capable of measuring activities ranging from 1 ÂµCi to 20 Ci or higher, depending on clinical needs.\n\n\nAccuracy:\n\nAccuracy within Â±2-5% across its entire measurement range, as required by regulatory guidelines.\n\n\nReproducibility:\n\nCoefficient of variation (precision) should typically be less than 1% for repeated measurements under the same conditions.\n\n\nDisplay:\n\nDigital LCD or LED readout, displaying activity in units like:\n\nMBq (Mega Becquerels)\n\nÂµCi or mCi (Micro or Milli Curie)\n\n\n\nIonization Chamber:\n\nType: Sealed, pressurized gas-filled chamber.\n\nPressure: Typically filled with argon gas at 15-20 atmospheres.\n\nChamber material: Typically aluminum or plastic housing with internal lead shielding.\n\n\nCalibration Factors:\n\nShould support pre-programmed isotope-specific calibration factors.\n\nAllow user-defined settings for custom isotopes.\n\n\nResponse Time:\n\nFast response, generally within 1-3 seconds.\n\n\nStability\n\nLong-term stability with drift correction, typically needing annual recalibration or quality control.\n\n\nQuality Control:\n\nIncludes self-diagnostic checks for:\n\nConstancy\n\nLinearity\n\nGeometry dependency\n\n\nQuality control standards must meet NRC, USP 825, or local equivalent regulatory requirements.\n\n\nSoftware/Interface:\n\nMay include connectivity via USB, Ethernet, or wireless for data storage and reporting.\n\nCompatible with PACS or EMR integration for documentation.\n\n\nPower Supply\n\nOperates on 120-240V AC or includes a battery backup for portability.\n\n\nDimensions and Weight:\n\nCompact size for placement in hot labs.\n\nWeight: 10-30 lbs depending on shielding and housing.\n\n\n\nAccessories:\n\nLead shielding rings or liners for high-energy isotopes.\n\nQuality control phantoms for accuracy testing.\n\nThe Capintec CAPRAC (Captus Radioactive Assay Calibrator) is a specialized gamma counter primarily used in nuclear medicine for wipe tests, bioassays, and other radioactivity measurements. Below are the general technical specifications for the CAPRAC systems:\n\n\nDetector:\n\nType: Sodium Iodide (NaI) scintillation detector\n\nSize: Typically 1  x 1  or similar for high sensitivity.\n\nEnergy Range: 15 keV to 2 MeV.\n\nShielding: 1/8-inch lead shielding around the detector to reduce background interference.\n\n\nSensitivity and Accuracy:\n\nCount Rate: Capable of high-sensitivity measurements.\n\nAccuracy: Â±1% for reproducibility of results.\n\nEfficiency: Designed to detect low levels of radiation with high precision, typically suitable for wipe tests with extremely low activity.\n\n\nEnergy Calibration:\n\nMulti-channel analyzer (MCA) included for energy-specific measurements.\n\nCalibrated for isotopes like:\n\nTc-99m\n\nI-123\n\nI-131\n\nF-18\n\nCs-137\n\n\nCustomizable isotope libraries for specific applications.\n\nDisplay and Software\n\nDisplay: Digital touchscreen interface (varies by model).\n\nData Output: Integrated software allows data to be saved, exported, and printed.\n\nReports: Can generate detailed reports for regulatory compliance.\n\nConnectivity: USB, Ethernet, or wireless options for data transfer to PACS or EMR systems.\n\nUser Programs: Allows for customizable QC protocols.\n\n\nQuality Control\n\nSelf-check protocols for:\n\nConstancy\n\nSensitivity\n\nEnergy Calibration\n\nSupports adherence to NRC, USP 825, and similar international regulatory guidelines.\n\n\nCounting Modes\n\nWipe Test Mode:\n\nDetects contamination and verifies cleaning protocols.\n\nProvides readings in counts per minute (CPM) or disintegrations per minute (DPM).\n\n\n\nBioassay Mode:\n\nMeasures small quantities of activity in biological samples.\n\n\nCustom Counting:\n\nAllows for user-defined assays or measurements.\n\nPower Supply:\n\nVoltage: Operates on standard 110-240V AC power.\n\nBattery backup option for uninterrupted operation.\n\n\nDimensions and Weight:\n\nSize: Compact design for bench-top placement.\n\nWeight: ~20-30 lbs depending on the shielding and detector configuration.\n\n\nRegulatory Compliance\n\nDesigned to comply with:\n\nNRC regulations for radiation detection.\n\nUSP 825 for radiopharmaceutical handling.\n\nCAP standards for laboratory operations.\n\n\nApplications:\n\nRoutine wipe testing for contamination monitoring.\n\nBioassay measurements for internal dose assessments.\n\nRoutine nuclear medicine quality control.\n\n\n\nSalient Characteristics for the Countertop Well Counter (CAPRAC-t):\n\n1. Touchscreen Interface: Features a modern touchscreen for user-friendly operation.\n\n\n2. High Sensitivity: Provides accurate wipe test and sample counting results.\n\n\n3. Auxiliary Shielding: Includes optional PET auxiliary shielding with 1 Â½-inch lead for enhanced radiation protection.\n\n\n4. Sample Testing: Accommodates a variety of test tubes and wipe test samples.\n\n\n5. Durability: Comes with removable screen protectors to ensure longevity.\n\n\n6. Compact Size: Designed for efficient countertop use in a hot lab or controlled space.\n\n\n7. Integrated Printing Capability: Compatible with roll printers for documentation of test results.\n\n\n8. Regulatory Compliance: Ensures adherence to NHPP standards for contamination testing and environmental safety.\n\nPlace of Performance: \n\nDepartment of Veterans Affairs\nBaltimore VA Medical Center\n10 N. Greene St.\nBaltimore MD 21201\n------------------------------------------------------------------------------------------------------------------------------ \nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. \nIf you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.\n(2) Is your company considered small under the NAICS code identified under this RFI?\n(3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?\n(4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n(5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.\n(6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract?\n(7) Please provide general pricing for your products/solutions for market research purposes.\n(8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes?\n*** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items\" meet all required salient characteristics.\nResponses to this notice shall be submitted via email to Michael.Jones16@va.gov.  Telephone responses shall not be accepted. Responses must be received no later than Thursday, February 13, 2024, at 10:00AM EST.  If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.","origin":"detail"},"contacts":[{"name":"Michael Jones","role":"primary","email":"michael.jones16@va.gov","phone":"(202) 745-8000 Ext. 52485","title":"Contract Specialist"}],"place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs Baltimore VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N. Greene St."},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"230cfd1928e443028c7df9e8e6f0eda8","name":"36C24525Q0287_1.docx","kind":"file","mime_type":".docx","size_bytes":35955,"posted_at":"2025-02-05T18:25:56.117Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/230cfd1928e443028c7df9e8e6f0eda8/download","mirrored":false}],"awards":[],"related":[{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24527Q0076","latest_notice_id":"9c0733493507403293e3d1367a3d19b5","title":"6530--MILITARY LITTERS, STANDS AND CARTS","solicitation_number":"36C24527Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"337127","psc":"6530","set_aside":null,"state":"WV","county":"54037","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"25430","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":53,"indexable":false}