{"canonical":"https://sealedbidder.com/opportunities/36c24525q0255","key":"36C24525Q0255","url":"https://sealedbidder.com/opportunities/36c24525q0255","title":"Q522--Sources Sought Notice Contrast Injector Service Contract","solicitation_number":"36C24525Q0255","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-01-27T13:00:00Z","first_posted":"2025-01-21","last_posted":"2025-01-21","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"339112","psc":"Q522","set_aside":null,"place_state":"MD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24510","place_county_name":"City of Baltimore","place_city":"2404000","place_city_name":"Baltimore","winner":null,"award_amount":null,"publications":[{"notice_id":"b0aef21a69d14d3781e0ce11e3d54dc9","title":"Q522--Sources Sought Notice Contrast Injector Service Contract","solicitation_number":"36C24525Q0255","notice_type":"r","base_type":"r","posted":"2025-01-21","posted_at":"2025-01-21T20:09:09.328Z","due_at":"2025-01-27T13:00:00Z","due_date":"2025-01-27","cancelled":false,"archived":true,"archive_date":"2025-02-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b0aef21a69d14d3781e0ce11e3d54dc9/view","enriched":true,"history":[{"index":6,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:16:00.331Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","solicitation_number":"36C24525Q0255","related_opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9"},{"index":4,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:09:09.328Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9","solicitation_number":"36C24525Q0255"}]},{"notice_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","title":"Q522--Sources Sought Notice Contrast Injector Service Contract","solicitation_number":"36C24525Q0255","notice_type":"o","base_type":"r","posted":"2025-01-21","posted_at":"2025-01-21T20:16:00.331Z","due_at":"2025-01-27T13:00:00Z","due_date":"2025-01-27","cancelled":false,"archived":true,"archive_date":"2025-02-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e1c8d91fb4b945c9a6cc9719fe54ddf0/view","enriched":true,"history":[{"index":6,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:16:00.331Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","solicitation_number":"36C24525Q0255","related_opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9"},{"index":4,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:09:09.328Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9","solicitation_number":"36C24525Q0255"}]}],"latest_notice_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-21","posted_at":"2025-01-21T20:09:09.328Z","created_at":"2025-01-21T20:09:07.162Z","modified_at":"2025-02-27T04:55:44.122Z","response_deadline":{"raw":"2025-01-27T08:00:00-05:00","utc":"2025-01-27T13:00:00Z","date":"2025-01-27","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b0aef21a69d14d3781e0ce11e3d54dc9/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-26","archive_type":"auto_custom"},"history":[{"index":6,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:16:00.331Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","solicitation_number":"36C24525Q0255","related_opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9"},{"index":4,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:09:09.328Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9","solicitation_number":"36C24525Q0255"}],"contacts":[{"name":"Keysha.Gorman74@va.gov","role":"primary","email":"Keysha.Gorman74@va.gov","phone":"410-637-1513","title":"Keysha Gorman"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"b0aef21a69d14d3781e0ce11e3d54dc9","lineage_id":"b0aef21a69d14d3781e0ce11e3d54dc9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T00:24:33.415630093Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"91d942215cbfa8d7c2eeaa971bd68524b6f0c59653cd7533392104c4104e4241","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T00:24:33.415630093Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought for a vendor to provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center.","text":"Sources Sought for a vendor to provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24525Q0255","place_of_performance":{"zip":"21201","city":{"code":"4000","name":"Baltimore"},"state":{"code":"MD","name":"Maryland"},"street":"Department of Veterans Affairs VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"10 N Greene St"},"product_service_code":"Q522"},{"award":{"awardee":{}},"dates":{"posted":"2025-01-21","posted_at":"2025-01-21T20:16:00.331Z","created_at":"2025-01-21T20:15:57.977Z","modified_at":"2025-02-27T04:55:44.122Z","response_deadline":{"raw":"2025-01-27T08:00:00-05:00","utc":"2025-01-27T13:00:00Z","date":"2025-01-27","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e1c8d91fb4b945c9a6cc9719fe54ddf0/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-26","archive_type":"auto_custom"},"history":[{"index":6,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:16:00.331Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","solicitation_number":"36C24525Q0255","related_opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9"},{"index":4,"title":"Q522--Sources Sought Notice Contrast Injector Service Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-21T20:09:09.328Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b0aef21a69d14d3781e0ce11e3d54dc9","solicitation_number":"36C24525Q0255"}],"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","lineage_id":"b0aef21a69d14d3781e0ce11e3d54dc9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T00:37:03.776805650Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"cf296934af5793f67a892edd35caf98e1dc3cb24d745ffc28d35c4ef9ec7d213","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T00:37:03.776805650Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"STATEMENT OF WORK\nSolicitation # \n\n\nGENERAL INFORMATION \n\nTitle of Project: Bayer Contrast Injector Service Contract\n\nScope of Work: The vendor will provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center and listed below to include preventative maintenance and calibration in accordance with the original equipment manufacturer (OEM) written specifications. Service coverage must include 100% coverage on parts/travel/labor charges, 100% coverage on replacement console/parts, 1 preventative maintenance every 12 months, all software updates, standard 2 business day shipping and other incidentals necessary to perform scheduled preventive maintenance and to restore the covered equipment to operating specifications in accordance with the manufacturer s specifications throughout the term of the contract. All parts must be certified to the OEM specifications. Additionally, the contractor must provide software and quality updates, technical and clinical application support by telephone, and remote monitoring and diagnostic support to minimize unexpected equipment downtime and maximize use of the equipment. \n\nThe vendor shall provide necessary hardware enhancements to upgrade contrast injectors that are end of life during the contract for each device into MEDRAD Stellant FLEX models. The vendor shall provide appropriate software updates to operate each device with these hardware enhancements.\n\nThe vendor will supply the Baltimore VAMC Biomedical Engineering department with a copy of a detailed service report that meets the requirements of 21CFR820, subpart N, within 2 weeks of maintenance being completed. The service shall be performed between the hours of 8:00am and 4:30pm, Monday through Friday, unless mutually agreed upon the contractor and the VA Biomedical Engineering department. The contractor shall schedule all maintenance with Biomedical Engineering and report to Biomedical Engineering in room 5B-183 upon arriving on-site at the Baltimore VAMC, before performing any maintenance.\n\nBelow is the list of equipment identified to be covered by this service contract and coverage needs:\nCoverage Monday   Friday, 8am-4:30pm\nTwo business day system replacement warranty \nSoftware and quality updates\nUptime commitment of 95%\n100% coverage on parts/travel/labor charges\nPreventative Maintenance every 12 months\n\nEquipment\nSerial #\nLast PM\nNext PM\nBayer MEDRAD Xperion MR Injector\n310338\n5/3/2024\n5/3/2025\nBayer Medrad Stellant FLEX Injector\n31473U1\n4/9/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n204061U1\n4/05/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n40477U1\n3/25/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n34128U1\n4/09/2024\n4/30/2025\nBayer Medrad Arterion Injector\n311635\n6/12/2024\n4/30/2025\nBayer Medrad Arterion Injector\n312221\n\n4/30/2025\nBayer Medrad Arterion Injector\n312126\n4/24/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20418\n4/17/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20426\n4/24/2024\n4/30/2024\n\nBackground: The VA Maryland Health Care System requires full-service coverage of the Bayer Medrad Injectors at the Baltimore VA Medical Center. This service coverage includes software and quality updates, replacement parts, 100% coverage on travel and labor costs, and preventative maintenance completed in accordance with the manufacturer s recommendations to ensure that the equipment is properly maintained and to reduce downtime of the identified equipment that results in cancellations of patient appointments. The VA Maryland Health Care System requires that all imaging equipment be maintained in accordance with the manufacturer s specifications. This equipment will be covered under a support agreement when it represents the best value for the Government.\n \nPerformance Period:  Base Year Plus 2 Option Years from time of award\n \nType of Contract: Maintenance services\n\nPlace of Performance: \nBaltimore VA Medical Center\n10 N. Greene St\nBaltimore, MD 21201\n\nPerformance Based Contract:  N/A\n\nSecurity:  The contractor must have photo ID available when performing work at a VA Medical Center and be willing to present it to VA staff. The vendor is responsible for personal protective equipment. The vendor must have a current Business Associate Agreement (BAA) with the Department of Veterans Affairs to perform maintenance on equipment that would result in incidental access to patient Protected Health Information (PHI).","text":"STATEMENT OF WORK\nSolicitation #\n\nGENERAL INFORMATION\n\nTitle of Project: Bayer Contrast Injector Service Contract\n\nScope of Work: The vendor will provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center and listed below to include preventative maintenance and calibration in accordance with the original equipment manufacturer (OEM) written specifications. Service coverage must include 100% coverage on parts/travel/labor charges, 100% coverage on replacement console/parts, 1 preventative maintenance every 12 months, all software updates, standard 2 business day shipping and other incidentals necessary to perform scheduled preventive maintenance and to restore the covered equipment to operating specifications in accordance with the manufacturer s specifications throughout the term of the contract. All parts must be certified to the OEM specifications. Additionally, the contractor must provide software and quality updates, technical and clinical application support by telephone, and remote monitoring and diagnostic support to minimize unexpected equipment downtime and maximize use of the equipment.\n\nThe vendor shall provide necessary hardware enhancements to upgrade contrast injectors that are end of life during the contract for each device into MEDRAD Stellant FLEX models. The vendor shall provide appropriate software updates to operate each device with these hardware enhancements.\n\nThe vendor will supply the Baltimore VAMC Biomedical Engineering department with a copy of a detailed service report that meets the requirements of 21CFR820, subpart N, within 2 weeks of maintenance being completed. The service shall be performed between the hours of 8:00am and 4:30pm, Monday through Friday, unless mutually agreed upon the contractor and the VA Biomedical Engineering department. The contractor shall schedule all maintenance with Biomedical Engineering and report to Biomedical Engineering in room 5B-183 upon arriving on-site at the Baltimore VAMC, before performing any maintenance.\n\nBelow is the list of equipment identified to be covered by this service contract and coverage needs:\nCoverage Monday Friday, 8am-4:30pm\nTwo business day system replacement warranty\nSoftware and quality updates\nUptime commitment of 95%\n100% coverage on parts/travel/labor charges\nPreventative Maintenance every 12 months\n\nEquipment\nSerial #\nLast PM\nNext PM\nBayer MEDRAD Xperion MR Injector\n310338\n5/3/2024\n5/3/2025\nBayer Medrad Stellant FLEX Injector\n31473U1\n4/9/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n204061U1\n4/05/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n40477U1\n3/25/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n34128U1\n4/09/2024\n4/30/2025\nBayer Medrad Arterion Injector\n311635\n6/12/2024\n4/30/2025\nBayer Medrad Arterion Injector\n312221\n\n4/30/2025\nBayer Medrad Arterion Injector\n312126\n4/24/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20418\n4/17/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20426\n4/24/2024\n4/30/2024\n\nBackground: The VA Maryland Health Care System requires full-service coverage of the Bayer Medrad Injectors at the Baltimore VA Medical Center. This service coverage includes software and quality updates, replacement parts, 100% coverage on travel and labor costs, and preventative maintenance completed in accordance with the manufacturer s recommendations to ensure that the equipment is properly maintained and to reduce downtime of the identified equipment that results in cancellations of patient appointments. The VA Maryland Health Care System requires that all imaging equipment be maintained in accordance with the manufacturer s specifications. This equipment will be covered under a support agreement when it represents the best value for the Government.\n\nPerformance Period: Base Year Plus 2 Option Years from time of award\n\nType of Contract: Maintenance services\n\nPlace of Performance:\nBaltimore VA Medical Center\n10 N. Greene St\nBaltimore, MD 21201\n\nPerformance Based Contract: N/A\n\nSecurity: The contractor must have photo ID available when performing work at a VA Medical Center and be willing to present it to VA staff. The vendor is responsible for personal protective equipment. The vendor must have a current Business Associate Agreement (BAA) with the Department of Veterans Affairs to perform maintenance on equipment that would result in incidental access to patient Protected Health Information (PHI).","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24525Q0255","product_service_code":"Q522"}],"due_at":"2025-01-27T13:00:00Z","due_date":"2025-01-27","closes_at":"2025-01-27T13:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-25T01:05:05.772969Z","principal_notice_id":"e1c8d91fb4b945c9a6cc9719fe54ddf0","description":{"text":"STATEMENT OF WORK\nSolicitation #\n\nGENERAL INFORMATION\n\nTitle of Project: Bayer Contrast Injector Service Contract\n\nScope of Work: The vendor will provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center and listed below to include preventative maintenance and calibration in accordance with the original equipment manufacturer (OEM) written specifications. Service coverage must include 100% coverage on parts/travel/labor charges, 100% coverage on replacement console/parts, 1 preventative maintenance every 12 months, all software updates, standard 2 business day shipping and other incidentals necessary to perform scheduled preventive maintenance and to restore the covered equipment to operating specifications in accordance with the manufacturer s specifications throughout the term of the contract. All parts must be certified to the OEM specifications. Additionally, the contractor must provide software and quality updates, technical and clinical application support by telephone, and remote monitoring and diagnostic support to minimize unexpected equipment downtime and maximize use of the equipment.\n\nThe vendor shall provide necessary hardware enhancements to upgrade contrast injectors that are end of life during the contract for each device into MEDRAD Stellant FLEX models. The vendor shall provide appropriate software updates to operate each device with these hardware enhancements.\n\nThe vendor will supply the Baltimore VAMC Biomedical Engineering department with a copy of a detailed service report that meets the requirements of 21CFR820, subpart N, within 2 weeks of maintenance being completed. The service shall be performed between the hours of 8:00am and 4:30pm, Monday through Friday, unless mutually agreed upon the contractor and the VA Biomedical Engineering department. The contractor shall schedule all maintenance with Biomedical Engineering and report to Biomedical Engineering in room 5B-183 upon arriving on-site at the Baltimore VAMC, before performing any maintenance.\n\nBelow is the list of equipment identified to be covered by this service contract and coverage needs:\nCoverage Monday Friday, 8am-4:30pm\nTwo business day system replacement warranty\nSoftware and quality updates\nUptime commitment of 95%\n100% coverage on parts/travel/labor charges\nPreventative Maintenance every 12 months\n\nEquipment\nSerial #\nLast PM\nNext PM\nBayer MEDRAD Xperion MR Injector\n310338\n5/3/2024\n5/3/2025\nBayer Medrad Stellant FLEX Injector\n31473U1\n4/9/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n204061U1\n4/05/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n40477U1\n3/25/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n34128U1\n4/09/2024\n4/30/2025\nBayer Medrad Arterion Injector\n311635\n6/12/2024\n4/30/2025\nBayer Medrad Arterion Injector\n312221\n\n4/30/2025\nBayer Medrad Arterion Injector\n312126\n4/24/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20418\n4/17/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20426\n4/24/2024\n4/30/2024\n\nBackground: The VA Maryland Health Care System requires full-service coverage of the Bayer Medrad Injectors at the Baltimore VA Medical Center. This service coverage includes software and quality updates, replacement parts, 100% coverage on travel and labor costs, and preventative maintenance completed in accordance with the manufacturer s recommendations to ensure that the equipment is properly maintained and to reduce downtime of the identified equipment that results in cancellations of patient appointments. The VA Maryland Health Care System requires that all imaging equipment be maintained in accordance with the manufacturer s specifications. This equipment will be covered under a support agreement when it represents the best value for the Government.\n\nPerformance Period: Base Year Plus 2 Option Years from time of award\n\nType of Contract: Maintenance services\n\nPlace of Performance:\nBaltimore VA Medical Center\n10 N. Greene St\nBaltimore, MD 21201\n\nPerformance Based Contract: N/A\n\nSecurity: The contractor must have photo ID available when performing work at a VA Medical Center and be willing to present it to VA staff. The vendor is responsible for personal protective equipment. The vendor must have a current Business Associate Agreement (BAA) with the Department of Veterans Affairs to perform maintenance on equipment that would result in incidental access to patient Protected Health Information (PHI).","html":"STATEMENT OF WORK\nSolicitation # \n\n\nGENERAL INFORMATION \n\nTitle of Project: Bayer Contrast Injector Service Contract\n\nScope of Work: The vendor will provide maintenance, support, and repair services for all the Bayer MedRad Injectors that are currently in use at the Baltimore VA Medical Center and listed below to include preventative maintenance and calibration in accordance with the original equipment manufacturer (OEM) written specifications. Service coverage must include 100% coverage on parts/travel/labor charges, 100% coverage on replacement console/parts, 1 preventative maintenance every 12 months, all software updates, standard 2 business day shipping and other incidentals necessary to perform scheduled preventive maintenance and to restore the covered equipment to operating specifications in accordance with the manufacturer s specifications throughout the term of the contract. All parts must be certified to the OEM specifications. Additionally, the contractor must provide software and quality updates, technical and clinical application support by telephone, and remote monitoring and diagnostic support to minimize unexpected equipment downtime and maximize use of the equipment. \n\nThe vendor shall provide necessary hardware enhancements to upgrade contrast injectors that are end of life during the contract for each device into MEDRAD Stellant FLEX models. The vendor shall provide appropriate software updates to operate each device with these hardware enhancements.\n\nThe vendor will supply the Baltimore VAMC Biomedical Engineering department with a copy of a detailed service report that meets the requirements of 21CFR820, subpart N, within 2 weeks of maintenance being completed. The service shall be performed between the hours of 8:00am and 4:30pm, Monday through Friday, unless mutually agreed upon the contractor and the VA Biomedical Engineering department. The contractor shall schedule all maintenance with Biomedical Engineering and report to Biomedical Engineering in room 5B-183 upon arriving on-site at the Baltimore VAMC, before performing any maintenance.\n\nBelow is the list of equipment identified to be covered by this service contract and coverage needs:\nCoverage Monday   Friday, 8am-4:30pm\nTwo business day system replacement warranty \nSoftware and quality updates\nUptime commitment of 95%\n100% coverage on parts/travel/labor charges\nPreventative Maintenance every 12 months\n\nEquipment\nSerial #\nLast PM\nNext PM\nBayer MEDRAD Xperion MR Injector\n310338\n5/3/2024\n5/3/2025\nBayer Medrad Stellant FLEX Injector\n31473U1\n4/9/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n204061U1\n4/05/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n40477U1\n3/25/2024\n4/30/2025\nBayer Medrad Stellant FLEX Injector\n34128U1\n4/09/2024\n4/30/2025\nBayer Medrad Arterion Injector\n311635\n6/12/2024\n4/30/2025\nBayer Medrad Arterion Injector\n312221\n\n4/30/2025\nBayer Medrad Arterion Injector\n312126\n4/24/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20418\n4/17/2024\n4/30/2024\nBayer Medrad Arterion Injector\n20426\n4/24/2024\n4/30/2024\n\nBackground: The VA Maryland Health Care System requires full-service coverage of the Bayer Medrad Injectors at the Baltimore VA Medical Center. This service coverage includes software and quality updates, replacement parts, 100% coverage on travel and labor costs, and preventative maintenance completed in accordance with the manufacturer s recommendations to ensure that the equipment is properly maintained and to reduce downtime of the identified equipment that results in cancellations of patient appointments. The VA Maryland Health Care System requires that all imaging equipment be maintained in accordance with the manufacturer s specifications. This equipment will be covered under a support agreement when it represents the best value for the Government.\n \nPerformance Period:  Base Year Plus 2 Option Years from time of award\n \nType of Contract: Maintenance services\n\nPlace of Performance: \nBaltimore VA Medical Center\n10 N. Greene St\nBaltimore, MD 21201\n\nPerformance Based Contract:  N/A\n\nSecurity:  The contractor must have photo ID available when performing work at a VA Medical Center and be willing to present it to VA staff. The vendor is responsible for personal protective equipment. The vendor must have a current Business Associate Agreement (BAA) with the Department of Veterans Affairs to perform maintenance on equipment that would result in incidental access to patient Protected Health Information (PHI).","origin":"detail"},"contacts":[{"name":"Keysha Gorman","role":"primary","email":"Keysha.Gorman74@va.gov","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"77abbdbf920048b3857cdd82e21ab39b","name":"36C24525Q0255.docx","kind":"file","mime_type":".docx","size_bytes":15705,"posted_at":"2025-01-21T20:16:00.331Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/77abbdbf920048b3857cdd82e21ab39b/download","mirrored":false},{"resource_id":"c4dbf9c0513c4101957e16c8725b7b4b","name":"36C24525Q0255_1.docx","kind":"file","mime_type":".docx","size_bytes":14003,"posted_at":"2025-01-21T20:09:09.328Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c4dbf9c0513c4101957e16c8725b7b4b/download","mirrored":false}],"awards":[],"related":[{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"NOIOLAOCC27001101","latest_notice_id":"352f21577e56484e9a1121550b56e448","title":"Intent to Sole Source - TELEMED ArtUs EXT-2H ultrasound system with RF module, two ultrasound transducers, and a ProbeFix Dynamic T probe holder","solicitation_number":"NOI-OLAO-CC-27-001101","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"339112","psc":"6515","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"75N98027Q00038SBPCANIA11810","latest_notice_id":"427cad0cab794e55b2ddb3fe92acc285","title":"Baxter/Hill-Rom Helux Pro Surgical Light System","solicitation_number":"75N98027Q00038SB_PCA-NIA-11810","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-08T19:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"339112","psc":"6515","set_aside":"SBA","state":"MD","county":"24003","county_name":"Anne Arundel County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0170","latest_notice_id":"8e384efad4304afa9f8a55c7438674ba","title":"MEDICAL EQUIPMENT AND SUPPLIES","solicitation_number":"W911S227U0170","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-25T06:17:21.102542Z"}],"similar_open_total":17,"indexable":false}