{"canonical":"https://sealedbidder.com/opportunities/36c24525b0003","key":"36C24525B0003","url":"https://sealedbidder.com/opportunities/36c24525b0003","title":"Z2DA--Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-05T18:00:00Z","first_posted":"2025-01-14","last_posted":"2025-03-28","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","place_state":"MD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24015","place_county_name":"Cecil County","place_city":null,"place_city_name":null,"winner":"JRG PRECISION CONSTRUCTION, LLC","award_amount":"103242.00","publications":[{"notice_id":"56b540b903734a69bcd99ba5394d1899","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"p","base_type":"p","posted":"2025-01-14","posted_at":"2025-01-14T14:08:06.911Z","due_at":null,"due_date":"2025-01-28","cancelled":false,"archived":true,"archive_date":"2025-03-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/56b540b903734a69bcd99ba5394d1899/view","enriched":true,"history":[{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T14:08:06.911Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"56b540b903734a69bcd99ba5394d1899","solicitation_number":"36C24525B0003"}]},{"notice_id":"ccd2e7bb05db49658d2272d721accf50","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"p","base_type":"p","posted":"2025-01-14","posted_at":"2025-01-14T21:27:35.876Z","due_at":"2025-01-28T17:00:00Z","due_date":"2025-01-28","cancelled":false,"archived":true,"archive_date":"2025-03-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ccd2e7bb05db49658d2272d721accf50/view","enriched":true,"history":[{"index":4,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T14:08:06.911Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"56b540b903734a69bcd99ba5394d1899","solicitation_number":"36C24525B0003"}]},{"notice_id":"c6d58139f9f44b99a88798481d2e83d1","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"o","base_type":"p","posted":"2025-01-29","posted_at":"2025-01-29T19:37:48.077Z","due_at":"2025-02-25T18:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-04-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c6d58139f9f44b99a88798481d2e83d1/view","enriched":true,"history":[{"index":7,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":6,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":4,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}]},{"notice_id":"396553feef484af58b1bd4d4a0417990","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"o","base_type":"o","posted":"2025-02-06","posted_at":"2025-02-06T20:22:08.182Z","due_at":"2025-02-25T18:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-03-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/396553feef484af58b1bd4d4a0417990/view","enriched":true,"history":[{"index":5,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}]},{"notice_id":"18b63a9e21094e3f965c47d7c638dc61","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"o","base_type":"o","posted":"2025-02-11","posted_at":"2025-02-11T17:04:59.018Z","due_at":"2025-02-25T18:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-03-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/18b63a9e21094e3f965c47d7c638dc61/view","enriched":true,"history":[{"index":5,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}]},{"notice_id":"16edebfabb1645fa9f08f0eb67604859","title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"o","base_type":"o","posted":"2025-02-20","posted_at":"2025-02-20T21:10:15.755Z","due_at":"2025-03-05T18:00:00Z","due_date":"2025-03-05","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/16edebfabb1645fa9f08f0eb67604859/view","enriched":true,"history":[{"index":8,"title":"Z2DA--Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:07:49.122Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","solicitation_number":"36C24525B0003","related_opportunity_id":"16edebfabb1645fa9f08f0eb67604859"},{"index":6,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}]},{"notice_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","title":"Z2DA--Repair 23H Fire Damage","solicitation_number":"36C24525B0003","notice_type":"a","base_type":"o","posted":"2025-03-28","posted_at":"2025-03-28T14:07:49.122Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-05-27","removed_at":null,"award_number":"36C24525C0073","awardee_name":"JRG Precision Construction, LLC","amount":"103242.00","link_sam":"https://sam.gov/workspace/contract/opp/56eeb2c0fbf24f05b8bdafbcba3f0e06/view","enriched":true,"history":[{"index":5,"title":"Z2DA--Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:07:49.122Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","solicitation_number":"36C24525B0003","related_opportunity_id":"16edebfabb1645fa9f08f0eb67604859"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"}]}],"latest_notice_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-14","posted_at":"2025-01-14T14:08:06.911Z","created_at":"2025-01-14T14:08:04.638Z","modified_at":"2025-03-29T04:04:34.394Z","response_deadline":{"raw":"2025-01-28","date":"2025-01-28"}},"links":{"sam":"https://sam.gov/workspace/contract/opp/56b540b903734a69bcd99ba5394d1899/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T14:08:06.911Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"56b540b903734a69bcd99ba5394d1899","solicitation_number":"36C24525B0003"}],"contacts":[{"name":"Brandon Parker","role":"primary","email":"brandon.parker2@va.gov","phone":"(410) 642-2411 ext.22818","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"56b540b903734a69bcd99ba5394d1899","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"56b540b903734a69bcd99ba5394d1899","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T03:38:36.884890309Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"f5bd572afba596d6eb01d74bfcf3fd7a30440cb1effdd8fc29a9797dce95c574","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T03:38:36.884890309Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Scope of Work   Building 23H Fire Damage Repairs   512A5-25-003\n\nWork Item 1:   The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup. \nAttachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base. \nApproximate total areas for repairs under project to be included in bid:\n1610 SF of new gypsum board wall installed on existing metal studs/hat channel.\n1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid)\n578 LF of rubber wall base\n1184 SF of carpet tile and mastic\n250 SF of luxury vinyl plank flooring and mastic\n6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR. \nContractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location.\nContractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size.\nContractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable. \nContractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1  Type X gypsum liner panel, 2Â½  CH metal studs, and 2 layers of 5/8  Type X gypsum board). \nContractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs. \nAll joints between gypsum board and other materials shall be fully caulked prior to painting. \nWork areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work.  Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes. \n\nWork Item 2:   The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor).\nExisting mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means. \nVA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material. \nContractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY.  All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov \n10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR Â§ 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR. \nPrepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.\n\nWork Item 3:  The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include:\nInstallation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18  with a 12-14  diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be  C-AJ-5210 .\nInfill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4  diameter hole with Â½-2  diameter pipe. Basis of Design UL Firestop Assembly shall be  C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal.","text":"Scope of Work Building 23H Fire Damage Repairs 512A5-25-003\n\nWork Item 1: The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup.\nAttachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base.\nApproximate total areas for repairs under project to be included in bid:\n1610 SF of new gypsum board wall installed on existing metal studs/hat channel.\n1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid)\n578 LF of rubber wall base\n1184 SF of carpet tile and mastic\n250 SF of luxury vinyl plank flooring and mastic\n6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR.\nContractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location.\nContractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size.\nContractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable.\nContractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1 Type X gypsum liner panel, 2Â½ CH metal studs, and 2 layers of 5/8 Type X gypsum board).\nContractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs.\nAll joints between gypsum board and other materials shall be fully caulked prior to painting.\nWork areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work. Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes.\n\nWork Item 2: The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor).\nExisting mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means.\nVA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material.\nContractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY. All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov\n10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR Â§ 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR.\nPrepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.\n\nWork Item 3: The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include:\nInstallation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18 with a 12-14 diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be C-AJ-5210 .\nInfill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4 diameter hole with Â½-2 diameter pipe. Basis of Design UL Firestop Assembly shall be C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","place_of_performance":{"zip":"21902","city":{"code":"61100","name":"Perry Point"},"state":{"code":"MD","name":"Maryland"},"street":"Perry Point VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"361 Boiler House Road"},"product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-01-14","posted_at":"2025-01-14T21:27:35.876Z","created_at":"2025-01-14T21:14:09.364Z","modified_at":"2025-03-29T04:04:34.394Z","response_deadline":{"raw":"2025-01-28T12:00:00-05:00","utc":"2025-01-28T17:00:00Z","date":"2025-01-28","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ccd2e7bb05db49658d2272d721accf50/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-29","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T14:08:06.911Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"56b540b903734a69bcd99ba5394d1899","solicitation_number":"36C24525B0003"}],"contacts":[{"name":"Brandon Parker","role":"primary","email":"brandon.parker2@va.gov","phone":"(410) 642-2411 ext.22818","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"ccd2e7bb05db49658d2272d721accf50","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"56b540b903734a69bcd99ba5394d1899","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T03:58:07.044626864Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5668dfb08909cc61b5572ed48240de5aeaffa685ffad54029b8e9d4e90fdfedf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T03:58:07.044626864Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Solicitation No. 36C24525B0003:&nbsp; The Department of Veterans Affairs (VA) Perry Point VA Medical Center located at Perry Point, MD intends to issue an Invitation for Bids (IFB) to award a single, firm fixed price contract for Construction Services. This project consists of the contractor providing all labor, materials, equipment, permits, transportation, and supervision necessary for the construction services for Project Number 512A5-25-003 &ldquo;Repair Fire Damage&rdquo;.&nbsp;</p>\n\n<p>Competition for this procurement is restricted to Service-Disabled Veteran Owned Small Businesses (SDVOSB).&nbsp; SDVOSB Firms that submit bids on SDVOSB set asides that are not verified will be deemed nonresponsive (Invitation for Bid).&nbsp; The magnitude of construction is $25,000.00-$100,000.00.&nbsp; The firm must be a general construction firm approved under NAICS: 236220, size standard: $39.5 million.&nbsp; The offeror shall obtain all necessary licenses or permits required to perform this work in the State of MD.&nbsp; Prospective contractors must be registered and current in the following websites: Veteran Small Business Certification and https://www.sam.gov to be eligible for award. Bids will be accepted from only responsible and responsive contractors.&nbsp; There will be a pre-bid site visit for this project which will be held at the Perry Point VA Medical Center, Perry Point, MD&nbsp; 21902.&nbsp; All interested parties are encouraged to attend the site visit.&nbsp; The date of the site visit will be confirmed in the solicitation.&nbsp; All questions generated from the site visit shall be submitted in writing to the contracting officer to brandon.parker2@va.gov.&nbsp; Prospective contractors may acquire solicitation documents, which are only available in .pdf electronic format by registering and downloading plans and specifications from the Contractor Opportunities website. Solicitation documents will be available on or about 1/28/2025.&nbsp; Approximate bid opening date is 02/18/2023.&nbsp; Firm site visit and bid opening dates will be provided on the solicitation once issued.&nbsp; There will be a public bid opening.&nbsp; Bidders are advised that award will be made to the responsive/responsible bidder with the lowest price.&nbsp; The procurement is subject to availability of funds.</p>\n\n<p>Note for Joint Venture (JV) Offerors: In accordance with VAAR 852.219-73(f) joint ventures may be eligible so long as the joint venture meets the requirements of 13 C.F.R. 128.402. In order to comply with 13 C.F.R. 128.402(e) JV offerors must include in their Volume I a certification, signed by an authorized official of each partner to the joint venture, stating that the parties to the joint venture (1) have entered into a joint venture agreement that fully complies with paragraph (c) of 13 CFR &sect; 128.402 and (2) will&nbsp; perform the contract in compliance with the joint venture agreement. Failure to submit the certification will render the offeror ineligible for award.</p>\n\n<p><strong>Scope of Work Building 23H Fire Damage Repairs 512A5-25-003</strong></p>\n\n<p>Work Item 1: The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup. Attachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base. Approximate total areas for repairs under project to be included in bid: 1610 SF of new gypsum board wall installed on existing metal studs/hat channel. 1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid) 578 LF of rubber wall base 1184 SF of carpet tile and mastic 250 SF of luxury vinyl plank flooring and mastic 6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR. Contractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location. Contractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size. Contractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable. Contractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1 Type X gypsum liner panel, 2&Acirc;&frac12; CH metal studs, and 2 layers of 5/8 Type X gypsum board). Contractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs. All joints between gypsum board and other materials shall be fully caulked prior to painting. Work areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work. Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes.</p>\n\n<p>Work Item 2: The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor). Existing mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means. VA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material. Contractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY. All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov 10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR &Acirc;&sect; 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR. Prepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.</p>\n\n<p>Work Item 3: The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include: Installation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18 with a 12-14 diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be C-AJ-5210 . Infill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4 diameter hole with &Acirc;&frac12;-2 diameter pipe. Basis of Design UL Firestop Assembly shall be C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal.</p>","text":"Solicitation No. 36C24525B0003: The Department of Veterans Affairs (VA) Perry Point VA Medical Center located at Perry Point, MD intends to issue an Invitation for Bids (IFB) to award a single, firm fixed price contract for Construction Services. This project consists of the contractor providing all labor, materials, equipment, permits, transportation, and supervision necessary for the construction services for Project Number 512A5-25-003 “Repair Fire Damage”.\n\nCompetition for this procurement is restricted to Service-Disabled Veteran Owned Small Businesses (SDVOSB). SDVOSB Firms that submit bids on SDVOSB set asides that are not verified will be deemed nonresponsive (Invitation for Bid). The magnitude of construction is $25,000.00-$100,000.00. The firm must be a general construction firm approved under NAICS: 236220, size standard: $39.5 million. The offeror shall obtain all necessary licenses or permits required to perform this work in the State of MD. Prospective contractors must be registered and current in the following websites: Veteran Small Business Certification and https://www.sam.gov to be eligible for award. Bids will be accepted from only responsible and responsive contractors. There will be a pre-bid site visit for this project which will be held at the Perry Point VA Medical Center, Perry Point, MD 21902. All interested parties are encouraged to attend the site visit. The date of the site visit will be confirmed in the solicitation. All questions generated from the site visit shall be submitted in writing to the contracting officer to brandon.parker2@va.gov. Prospective contractors may acquire solicitation documents, which are only available in .pdf electronic format by registering and downloading plans and specifications from the Contractor Opportunities website. Solicitation documents will be available on or about 1/28/2025. Approximate bid opening date is 02/18/2023. Firm site visit and bid opening dates will be provided on the solicitation once issued. There will be a public bid opening. Bidders are advised that award will be made to the responsive/responsible bidder with the lowest price. The procurement is subject to availability of funds.\n\nNote for Joint Venture (JV) Offerors: In accordance with VAAR 852.219-73(f) joint ventures may be eligible so long as the joint venture meets the requirements of 13 C.F.R. 128.402. In order to comply with 13 C.F.R. 128.402(e) JV offerors must include in their Volume I a certification, signed by an authorized official of each partner to the joint venture, stating that the parties to the joint venture (1) have entered into a joint venture agreement that fully complies with paragraph (c) of 13 CFR § 128.402 and (2) will perform the contract in compliance with the joint venture agreement. Failure to submit the certification will render the offeror ineligible for award.\n\nScope of Work Building 23H Fire Damage Repairs 512A5-25-003\n\nWork Item 1: The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup. Attachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base. Approximate total areas for repairs under project to be included in bid: 1610 SF of new gypsum board wall installed on existing metal studs/hat channel. 1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid) 578 LF of rubber wall base 1184 SF of carpet tile and mastic 250 SF of luxury vinyl plank flooring and mastic 6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR. Contractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location. Contractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size. Contractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable. Contractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1 Type X gypsum liner panel, 2Â½ CH metal studs, and 2 layers of 5/8 Type X gypsum board). Contractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs. All joints between gypsum board and other materials shall be fully caulked prior to painting. Work areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work. Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes.\n\nWork Item 2: The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor). Existing mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means. VA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material. Contractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY. All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov 10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR Â§ 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR. Prepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.\n\nWork Item 3: The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include: Installation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18 with a 12-14 diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be C-AJ-5210 . Infill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4 diameter hole with Â½-2 diameter pipe. Basis of Design UL Firestop Assembly shall be C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","place_of_performance":{"zip":"21902","city":{"code":"61100","name":"Perry Point"},"state":{"code":"MD","name":"Maryland"},"street":"Perry Point VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"361 Boiler House Road"},"product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-01-29","posted_at":"2025-01-29T19:37:48.077Z","created_at":"2025-01-29T19:37:10.388Z","modified_at":"2025-04-05T03:55:49.678Z","response_deadline":{"raw":"2025-02-25T13:00:00-05:00","utc":"2025-02-25T18:00:00Z","date":"2025-02-25","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c6d58139f9f44b99a88798481d2e83d1/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-26","archive_type":"auto_custom"},"history":[{"index":7,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":6,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-14T21:27:35.876Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"ccd2e7bb05db49658d2272d721accf50","solicitation_number":"36C24525B0003","parent_opportunity_id":"56b540b903734a69bcd99ba5394d1899"},{"index":4,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}],"contacts":[{"name":"Brandon S Parker","role":"primary","email":"Brandon.Parker2@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"c6d58139f9f44b99a88798481d2e83d1","lineage_id":"c6d58139f9f44b99a88798481d2e83d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T03:44:50.634540148Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"bdb484f02221fb5d09fd2857e5db324ef2147f3bf31c8f0866e15c5b4a975d22","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T03:44:50.634540148Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"SCOPE OF WORK\n\nPROJECT DATA:\n\nVA Project Title:   Building 23H Fire Damage Repairs\n\nVA Project No:   512A5-25-003\n\nVA Facility:    Perry Point VA Medical Center\n    Perry, Point, MD\n\nPeriod of Performance:  90 calendar days from contract Notice to Proceed\n\nProject Background:\nOn the evening of October 23, 2024, a fire occurred located on the roof of Building 23H. The fire was extinguished with no major damages to 23H. There was minor damages and wetted areas from the use of fire hoses. A remediation contractor was engaged to remove all wetted ceiling tiles, wetted carpet, wetted drywall, wetted wall base, and wetted insulation from the project site. A separate contract is now being contemplated to complete the repair/restoration work required to return the damaged building areas to active service use.\nWork Scope:\nWork Item 1:   The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup. \nAttachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base. \nApproximate total areas for repairs under project to be included in bid:\n1610 SF of new gypsum board wall installed on existing metal studs/hat channel.\n1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid)\n578 LF of rubber wall base\n1184 SF of carpet tile and mastic\n250 SF of luxury vinyl plank flooring and mastic\n6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR. \nContractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location.\nContractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size.\nContractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable. \nContractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1  Type X gypsum liner panel, 2Â½  CH metal studs, and 2 layers of 5/8  Type X gypsum board). \nContractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs. \nAll joints between gypsum board and other materials shall be fully caulked prior to painting. \nWork areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work.  Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes. \n\nWork Item 2:   The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor).\nExisting mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means. \nVA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material. \nContractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY.  All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov \n10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR Â§ 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR. \nPrepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.\n\nWork Item 3:  The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include:\nInstallation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18  with a 12-14  diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be  C-AJ-5210 .\nInfill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4  diameter hole with Â½-2  diameter pipe. Basis of Design UL Firestop Assembly shall be  C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal. \n\nSafety and Environmental Precautions:\nThe Contractor shall comply with all applicable Federal, State, and local legal requirements regarding workers health and safety.  The requirements include but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926.  Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthful working conditions for its employees.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS shall be enforced. Contractor Supervisor must have 30-hour OSHA Construction Safety course. All contractor employees must have 10-hour OSHA Construction Safety course.\nFollow all ICRA guidelines for dust control during all construction and demolition work. A construction dust  Risk Assessment  will be conducted by the Medical Center s Infection Control Nurse. Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment. \nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\nThe Contractor shall perform the work in a manner consistent with the area security and fire safety regulations especially with regards to exits and exit way access. Utility shutdowns shall not compromise security, communication, or fire safety for occupants.\nThe work is in a professional environment, employees must conduct themselves accordingly.  Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site.  Employee's dress code shall consist of normal work uniform.  Shirts must be worn at all times.\nNo flammable liquids shall be stored or used in the medical center.\nThe Contractor shall receive from the station fire department a permit for all cutting, welding, and soldering.  All permits shall be prominently displayed during all construction. Permits must be opened at the start of each activity and closed at the end of each workday.\nIn order to provide for control of all environmentally hazardous materials arising from demolition and/or construction activities, the Contractor shall comply with all applicable environmentally hazardous material control and all applicable provisions of the Corps of Engineers  Manual EM 385-1-1,  General Safety Requirements  as well as the specific requirements stated elsewhere in the Contract Documents.\nDisposal and/or recycling of all demolished building materials and construction waste per applicable regulations shall be included.\nConstruction Requirements:\nThe Contractor shall have the skills, availability, capacity, and all other required resources required to complete the job on time without delay.\nAll work shall comply with local, state, and federal rules and regulations, and VA technical standards.\nIf not specified, all work shall meet or exceed the specifications of currently installed work.\nProvide daily on-site project management to coordinate all building trades and provide liaison for construction and VA Project Engineering. Superintendent and Site Safety and Health Officer shall be designated and shall be always present at the project site.\nAll employees of contractor shall comply with VA Security management program and obtain permission of the VA police, be identified by project and employer, and be restricted from unauthorized access.  VA issued ID Badges shall be worn by all workers while within the campus boundaries. Contractor shall make all necessary arrangements to obtain the required security investigation for badging prior to commencement of on-site work. VA issued ID Badges shall be always worn by all workers.\nAll equipment and materials shall be approved prior to being brought on job site. Buy American-Construction Materials clause applies to all construction material purchases.\nNormal work hours are Monday through Friday 7:00 a.m. to 4:30 p.m.  Contractor shall make prior arrangements to work earlier or later with Project Manager. VA shall not grant access to sub-contractors; it is the responsibility of the contractor.\nUnless noted otherwise, all new surface repair work shall match the existing adjacent work to the maximum extent practicable. \nContractor shall provide general clean up to construction area daily to the satisfaction of the COR.\nWarranty on new work shall extend for a period of no less than 1 year from date of final acceptance of project completion per FAR.\n\nAttached References: \nThe references noted below supplement this scope of work\nAttachment 1:   23H Repair Area Estimation \nAttachment 2:   23H Floor Plans\nAttachment 3:   512A5-25-003 Combined Specifications\n\n\n-----END OF SCOPE OF WORK-----","text":"SCOPE OF WORK\n\nPROJECT DATA:\n\nVA Project Title: Building 23H Fire Damage Repairs\n\nVA Project No: 512A5-25-003\n\nVA Facility: Perry Point VA Medical Center\nPerry, Point, MD\n\nPeriod of Performance: 90 calendar days from contract Notice to Proceed\n\nProject Background:\nOn the evening of October 23, 2024, a fire occurred located on the roof of Building 23H. The fire was extinguished with no major damages to 23H. There was minor damages and wetted areas from the use of fire hoses. A remediation contractor was engaged to remove all wetted ceiling tiles, wetted carpet, wetted drywall, wetted wall base, and wetted insulation from the project site. A separate contract is now being contemplated to complete the repair/restoration work required to return the damaged building areas to active service use.\nWork Scope:\nWork Item 1: The contractor shall provide all supervision, labor, materials, and equipment to replace the acoustical ceiling tiles, flooring, gypsum board walls, and wall base that were previously removed as part of the fire damage cleanup.\nAttachment 1 contains a detailed breakdown of the projected repair area included in each room for ceiling tiles, flooring, drywall, paint, and wall base.\nApproximate total areas for repairs under project to be included in bid:\n1610 SF of new gypsum board wall installed on existing metal studs/hat channel.\n1640 SF of acoustical ceiling tile (including minor repairs to existing suspension grid)\n578 LF of rubber wall base\n1184 SF of carpet tile and mastic\n250 SF of luxury vinyl plank flooring and mastic\n6685 SF of wall patching/skim coat and painting. 4th Floor office suite to be fully repainted after wall repairs. Coordinate color selections with COR.\nContractor shall include the removal and reinstallation of existing wall paintings, door tags, TV mounts, bulletin boards, and other signage/artwork as required to repair and repaint walls. VA to provide temporary storage location.\nContractor to provide and install a new grid-supported HVAC supply diffuser (2x2) with manual damper and flexible ductwork in room 409 to replace one removed during demolition phase. Coordinate with existing duct size.\nContractor shall remove and replace all electrical receptacle and switch cover plates within the work area that were damaged during the water damage remediation phase. Replacement cover plates shall be type 302 stainless steel matching the type and color removed. Oversize plates are not acceptable.\nContractor shall remove and rebuild the existing 2HR rated UL shaft-wall system (UL U415 System B) around the existing generator exhaust pipe (including 1 Type X gypsum liner panel, 2Â½ CH metal studs, and 2 layers of 5/8 Type X gypsum board).\nContractor shall include all accessories required for the complete installation of all finish systems, including but not limited to stainless-steel flooring transition strips, light-gage or wood furring/blocking, and ACT suspension grid accessories/pieces for repairs.\nAll joints between gypsum board and other materials shall be fully caulked prior to painting.\nWork areas are currently isolated from the rest of the hospital with temporary partitions (hard wall or plastic sheeting). Contractor shall provide for any supplemental infection control barriers and ICRA preventative measures required by the work. Level 3 Infection Control Risk Assessment (ICRA) Controls (including negative pressure exhaust) will be required during all drywall and flooring work to control dust and fumes.\n\nWork Item 2: The contractor shall engage the services of a Maryland State licensed abatement contractor to remove approximately 1300 SF of residual black mastic from previously removed tile flooring on the 4th floor upper level (rooms 406-410 and 4th floor corridor).\nExisting mastic is non-friable and has been previously scarified by mechanical means, but a residual base layer remains that must be removed by chemical means.\nVA will provide their own VPIH consultant to conduct background air monitoring and clearance testing for internal purposes. Contractor shall provide their own separate CIH in accordance with OSHA to conduct continuous air monitoring and final TEM clearance after removal of material.\nContractor shall provide legal disposal of all asbestos waste per COMAR 26-11-21-08 Asbestos Waste Disposal. Records of hazardous waste disposal (such as manifests, hazardous waste profiles, LDRs) MUST be provided by approved waste transporter and signed by an approved VAMHCS Manifest signer from the VAMHCS Safety Department ONLY. All records provided to COR and VAMHCS GEMS Coordinator at VAMHCSGEMSProgram@va.gov\n10-day NESHAPS notification to MDE and the EPA for demolition or renovation (40 CFR Â§ 61.145, Figure 3, Notification of Demolition and Renovation), Provide completed copy to VAMHCS Projects COR.\nPrepare and submit asbestos abatement plan to VAMHCS Projects COR for approval before proceeding with work.\n\nWork Item 3: The contractor shall seal existing penetrations within the work area between floors with the appropriate fire-rated material and/or fire caulking. This scope specifically shall include:\nInstallation of a UL-listed 2hr fireproofing assembly around an existing generator exhaust pipe penetration through the concrete floor at the 2nd, 3rd, and 4th floor levels (located in the corner of room 1G-108, 227, 323, and 409). Approximate floor penetration is roughly 18 x18 with a 12-14 diameter insulated pipe passing though. Basis of Design UL Firestop Assembly shall be C-AJ-5210 .\nInfill/Fireproofing around all existing radiator steam pipe penetrations within the work area. Approximate 4 diameter hole with Â½-2 diameter pipe. Basis of Design UL Firestop Assembly shall be C-AJ-1551 . Contractor shall include infill of (2) penetrations at each radiator (located below windows within work area) in proposal.\n\nSafety and Environmental Precautions:\nThe Contractor shall comply with all applicable Federal, State, and local legal requirements regarding workers health and safety. The requirements include but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926. Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthful working conditions for its employees.\nOSHA and VA CONSTRUCTION SAFETY STANDARDS shall be enforced. Contractor Supervisor must have 30-hour OSHA Construction Safety course. All contractor employees must have 10-hour OSHA Construction Safety course.\nFollow all ICRA guidelines for dust control during all construction and demolition work. A construction dust Risk Assessment will be conducted by the Medical Center s Infection Control Nurse. Bi-weekly inspections of barriers and work areas will be conducted by Infection Control Nurse, Safety Manager, and COR to enforce implementation of risk assessment.\nContractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property.\nThe Contractor shall perform the work in a manner consistent with the area security and fire safety regulations especially with regards to exits and exit way access. Utility shutdowns shall not compromise security, communication, or fire safety for occupants.\nThe work is in a professional environment, employees must conduct themselves accordingly. Employees shall not use abusive language, carry firearms, or bring alcoholic beverages on site. Employee's dress code shall consist of normal work uniform. Shirts must be worn at all times.\nNo flammable liquids shall be stored or used in the medical center.\nThe Contractor shall receive from the station fire department a permit for all cutting, welding, and soldering. All permits shall be prominently displayed during all construction. Permits must be opened at the start of each activity and closed at the end of each workday.\nIn order to provide for control of all environmentally hazardous materials arising from demolition and/or construction activities, the Contractor shall comply with all applicable environmentally hazardous material control and all applicable provisions of the Corps of Engineers Manual EM 385-1-1, General Safety Requirements as well as the specific requirements stated elsewhere in the Contract Documents.\nDisposal and/or recycling of all demolished building materials and construction waste per applicable regulations shall be included.\nConstruction Requirements:\nThe Contractor shall have the skills, availability, capacity, and all other required resources required to complete the job on time without delay.\nAll work shall comply with local, state, and federal rules and regulations, and VA technical standards.\nIf not specified, all work shall meet or exceed the specifications of currently installed work.\nProvide daily on-site project management to coordinate all building trades and provide liaison for construction and VA Project Engineering. Superintendent and Site Safety and Health Officer shall be designated and shall be always present at the project site.\nAll employees of contractor shall comply with VA Security management program and obtain permission of the VA police, be identified by project and employer, and be restricted from unauthorized access. VA issued ID Badges shall be worn by all workers while within the campus boundaries. Contractor shall make all necessary arrangements to obtain the required security investigation for badging prior to commencement of on-site work. VA issued ID Badges shall be always worn by all workers.\nAll equipment and materials shall be approved prior to being brought on job site. Buy American-Construction Materials clause applies to all construction material purchases.\nNormal work hours are Monday through Friday 7:00 a.m. to 4:30 p.m. Contractor shall make prior arrangements to work earlier or later with Project Manager. VA shall not grant access to sub-contractors; it is the responsibility of the contractor.\nUnless noted otherwise, all new surface repair work shall match the existing adjacent work to the maximum extent practicable.\nContractor shall provide general clean up to construction area daily to the satisfaction of the COR.\nWarranty on new work shall extend for a period of no less than 1 year from date of final acceptance of project completion per FAR.\n\nAttached References:\nThe references noted below supplement this scope of work\nAttachment 1: 23H Repair Area Estimation\nAttachment 2: 23H Floor Plans\nAttachment 3: 512A5-25-003 Combined Specifications\n\n-----END OF SCOPE OF WORK-----","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-06","posted_at":"2025-02-06T20:22:08.182Z","created_at":"2025-02-06T20:22:05.609Z","modified_at":"2025-04-05T03:55:49.678Z","response_deadline":{"raw":"2025-02-25T13:00:00-05:00","utc":"2025-02-25T18:00:00Z","date":"2025-02-25","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/396553feef484af58b1bd4d4a0417990/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-27","archive_type":"auto_custom"},"history":[{"index":5,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}],"contacts":[{"name":"Brandon S Parker","role":"primary","email":"Brandon.Parker2@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"396553feef484af58b1bd4d4a0417990","lineage_id":"c6d58139f9f44b99a88798481d2e83d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-23T02:53:15.298669760Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"0b58f531b9d1af37ea1d9aa7e2f84e4e6766c14e193c6dff59efbdf6af642d93","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-23T02:53:15.298669760Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"IFB AMEND","text":"IFB AMEND","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-11","posted_at":"2025-02-11T17:04:59.018Z","created_at":"2025-02-11T17:04:57.454Z","modified_at":"2025-04-05T03:55:49.678Z","response_deadline":{"raw":"2025-02-25T13:00:00-05:00","utc":"2025-02-25T18:00:00Z","date":"2025-02-25","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/18b63a9e21094e3f965c47d7c638dc61/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-27","archive_type":"auto_custom"},"history":[{"index":5,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}],"contacts":[{"name":"Brandon S Parker","role":"primary","email":"Brandon.Parker2@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"18b63a9e21094e3f965c47d7c638dc61","lineage_id":"c6d58139f9f44b99a88798481d2e83d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T12:45:56.953729269Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"52ed80fbe03f3e9c26824128453a75717d2b1b7f4b980576c3e3d3d0698d2111","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T12:45:56.953729269Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"SOW","text":"SOW","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","product_service_code":"Z2DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-02-20","posted_at":"2025-02-20T21:10:15.755Z","created_at":"2025-02-20T21:09:47.342Z","modified_at":"2025-04-05T03:55:49.678Z","response_deadline":{"raw":"2025-03-05T13:00:00-05:00","utc":"2025-03-05T18:00:00Z","date":"2025-03-05","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/16edebfabb1645fa9f08f0eb67604859/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto_custom"},"history":[{"index":8,"title":"Z2DA--Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:07:49.122Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","solicitation_number":"36C24525B0003","related_opportunity_id":"16edebfabb1645fa9f08f0eb67604859"},{"index":6,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-11T17:04:59.018Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"18b63a9e21094e3f965c47d7c638dc61","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":2,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-06T20:22:08.182Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"396553feef484af58b1bd4d4a0417990","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"},{"index":1,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T19:37:48.077Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"c6d58139f9f44b99a88798481d2e83d1","solicitation_number":"36C24525B0003","related_opportunity_id":"ccd2e7bb05db49658d2272d721accf50"}],"contacts":[{"name":"Brandon S Parker","role":"primary","email":"Brandon.Parker2@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"16edebfabb1645fa9f08f0eb67604859","lineage_id":"c6d58139f9f44b99a88798481d2e83d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T03:34:48.565345917Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a7debc1e7854fcc3f18e572ad143bbabe04a20c37a34faeabba770e365623998","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T03:34:48.565345917Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"RFIs","text":"RFIs","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24525B0003","product_service_code":"Z2DA"},{"award":{"date":"2025-03-18","amount":"103242.00","number":"36C24525C0073","awardee":{"raw":"JRG Precision Construction, LLC OWINGS 20736","uei":"F8H2CBKK9FG8","cage":"9PZW9","name":"JRG Precision Construction, LLC","location":{"zip":"20736","city":{"name":"OWINGS"},"state":{"name":"MD"},"country":{"name":"MD"}}}},"dates":{"posted":"2025-03-28","posted_at":"2025-03-28T14:07:49.122Z","award_date":"2025-03-18","created_at":"2025-03-28T14:07:43.875Z","modified_at":"2025-05-28T04:00:10.042Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/56eeb2c0fbf24f05b8bdafbcba3f0e06/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--Repair 23H Fire Damage","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-27","archive_type":"auto_custom"},"history":[{"index":5,"title":"Z2DA--Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-28T14:07:49.122Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","solicitation_number":"36C24525B0003","related_opportunity_id":"16edebfabb1645fa9f08f0eb67604859"},{"index":3,"title":"Z2DA--512A5-25-003 Repair 23H Fire Damage","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-20T21:10:15.755Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"16edebfabb1645fa9f08f0eb67604859","solicitation_number":"36C24525B0003","parent_opportunity_id":"c6d58139f9f44b99a88798481d2e83d1"}],"contacts":[{"name":"Brandon Parker","role":"primary","email":"brandon.parker2@va.gov","phone":"(410) 642-2411","title":"Contract Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"c6d58139f9f44b99a88798481d2e83d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T11:46:32.240010157Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d59e90578eea64d34c641377b08bd9b1b38ae04aae9ac994047464e239e49372","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T11:46:32.240010157Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Awarded","text":"Awarded","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24525B0003","product_service_code":"Z2DA"}],"due_at":"2025-03-05T18:00:00Z","due_date":"2025-03-05","closes_at":"2025-03-05T18:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"MD","county":"24015","county_name":"Cecil County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"F8H2CBKK9FG8","amount":"103242.00","linked_awards":7,"cancelled":false,"archived":true,"updated_at":"2026-11-19T11:46:39.760936Z","principal_notice_id":"56eeb2c0fbf24f05b8bdafbcba3f0e06","description":{"text":"Awarded","html":"Awarded","origin":"detail"},"contacts":[{"name":"Brandon Parker","role":"primary","email":"brandon.parker2@va.gov","phone":"(410) 642-2411","title":"Contract Officer"}],"place_of_performance":null,"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["236220"],"award":{"date":"2025-03-18","amount":"103242.00","number":"36C24525C0073","awardee":{"raw":"JRG Precision Construction, LLC OWINGS 20736","uei":"F8H2CBKK9FG8","cage":"9PZW9","name":"JRG Precision Construction, LLC","location":{"zip":"20736","city":{"name":"OWINGS"},"state":{"name":"MD"},"country":{"name":"MD"}}}},"attachments":[{"resource_id":"bf6d56755c7444f0804d3f4de9ffbc75","name":"36C24525B0003.docx","kind":"file","mime_type":".docx","size_bytes":26689,"posted_at":"2025-01-14T14:08:06.911Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bf6d56755c7444f0804d3f4de9ffbc75/download","mirrored":false},{"resource_id":"c78e2cd3207c4f8297c0dcbd0585b466","name":"36C24525B0003_1.docx","kind":"file","mime_type":".docx","size_bytes":123664,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c78e2cd3207c4f8297c0dcbd0585b466/download","mirrored":false},{"resource_id":"50d1927337d247aa834b4cdcde6f7540","name":"36C24525C0073_1.docx","kind":"file","mime_type":".docx","size_bytes":13747,"posted_at":"2025-03-28T14:07:49.122Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/50d1927337d247aa834b4cdcde6f7540/download","mirrored":false},{"resource_id":"9baa2850df914cadb337867f86f6b25e","name":"Department of Veterans Affairs","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-03-28T14:07:49.122Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"bd5074c3357b44fea865af4e8f94e5be","name":"U.S. Department of Veterans Affairs","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-01-14T14:08:06.911Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"53ebeca46fa8441aaf866deb53dfa930","name":"Wage Determination MD20250049.pdf","kind":"file","mime_type":".pdf","size_bytes":2202636,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/53ebeca46fa8441aaf866deb53dfa930/download","mirrored":false},{"resource_id":"d2416e9f5d7e42dcb1d86319be17ce9b","name":"Parking Location for 23H Site Visit.pdf","kind":"file","mime_type":".pdf","size_bytes":379981,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d2416e9f5d7e42dcb1d86319be17ce9b/download","mirrored":false},{"resource_id":"dd8f52217f084f6baaed57748babcbd1","name":"Attachment 1 - 23H Area Estimation Rev1.pdf","kind":"file","mime_type":".pdf","size_bytes":103435,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dd8f52217f084f6baaed57748babcbd1/download","mirrored":false},{"resource_id":"f436ab8d97bc4918bcf5cff74e536fbc","name":"Attachment 2 - 23H Floor Plans.pdf","kind":"file","mime_type":".pdf","size_bytes":2910986,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f436ab8d97bc4918bcf5cff74e536fbc/download","mirrored":false},{"resource_id":"ae0f803c96d6470c919fa4ab71d4ee55","name":"Attachment 3 - 512A5-25-003 Combined Specs Rev1.pdf","kind":"file","mime_type":".pdf","size_bytes":2232530,"posted_at":"2025-01-29T19:37:48.077Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ae0f803c96d6470c919fa4ab71d4ee55/download","mirrored":false},{"resource_id":"f9de27e25bf64df981e2af0839616c24","name":"36C24525B0003 0001.docx","kind":"file","mime_type":".docx","size_bytes":16588,"posted_at":"2025-02-06T20:22:08.182Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f9de27e25bf64df981e2af0839616c24/download","mirrored":false},{"resource_id":"665fff4e10854c43bb23ddebf97578a3","name":"RFI Form.xlsx","kind":"file","mime_type":".xlsx","size_bytes":12098,"posted_at":"2025-02-06T20:22:08.182Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/665fff4e10854c43bb23ddebf97578a3/download","mirrored":false},{"resource_id":"3bae7e987ab54d8282269dc9a9af0787","name":"512A5-25-003 Construction Visit Roster.pdf","kind":"file","mime_type":".pdf","size_bytes":69591,"posted_at":"2025-02-06T20:22:08.182Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3bae7e987ab54d8282269dc9a9af0787/download","mirrored":false},{"resource_id":"8af2e24d3e9748ba9f6f42725ca501df","name":"36C24525B0003 0002.docx","kind":"file","mime_type":".docx","size_bytes":16717,"posted_at":"2025-02-11T17:04:59.018Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8af2e24d3e9748ba9f6f42725ca501df/download","mirrored":false},{"resource_id":"9b6685b9277b44dfa7bf9b0ef9688619","name":"512A5-25-003 23H Fire Damage Repairs SOW Rev2 - Amend 0002 -02112025.pdf","kind":"file","mime_type":".pdf","size_bytes":547648,"posted_at":"2025-02-11T17:04:59.018Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9b6685b9277b44dfa7bf9b0ef9688619/download","mirrored":false},{"resource_id":"c8a2289425c448998d3b1d4e8fd964e7","name":"36C24525B0003 0003.docx","kind":"file","mime_type":".docx","size_bytes":16818,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c8a2289425c448998d3b1d4e8fd964e7/download","mirrored":false},{"resource_id":"80d057f4645b4d0b9141ac52ef1be389","name":"512A5-25-003 Construction RFIs Rev.1.pdf","kind":"file","mime_type":".pdf","size_bytes":489466,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/80d057f4645b4d0b9141ac52ef1be389/download","mirrored":false},{"resource_id":"8e563ad5b1de4c44a9895aee74608b79","name":"PP-23H-2-First Floor.pdf","kind":"file","mime_type":".pdf","size_bytes":261095,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8e563ad5b1de4c44a9895aee74608b79/download","mirrored":false},{"resource_id":"a2fcae88a5204c53869d78600cff13df","name":"PP-23H-4-Third Floor.pdf","kind":"file","mime_type":".pdf","size_bytes":227195,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a2fcae88a5204c53869d78600cff13df/download","mirrored":false},{"resource_id":"ea2a8e29d99049edb8411c52bbd14c53","name":"PP-23H-3-Second Floor.pdf","kind":"file","mime_type":".pdf","size_bytes":238237,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ea2a8e29d99049edb8411c52bbd14c53/download","mirrored":false},{"resource_id":"e20a2c79d5404c15a1930689f919cbca","name":"PP-23H-5-Fourth Floor.pdf","kind":"file","mime_type":".pdf","size_bytes":113384,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e20a2c79d5404c15a1930689f919cbca/download","mirrored":false},{"resource_id":"70f9aefad1d44b8a83403b80861064e1","name":"Amended Specs.pdf","kind":"file","mime_type":".pdf","size_bytes":308766,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/70f9aefad1d44b8a83403b80861064e1/download","mirrored":false},{"resource_id":"f15275f874cb44468f6c4b35fcfd848f","name":"DryingReport_Nov-15-2024.pdf","kind":"file","mime_type":".pdf","size_bytes":518939,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f15275f874cb44468f6c4b35fcfd848f/download","mirrored":false},{"resource_id":"588d3b4106ef438ab7ee409f3e84fed7","name":"23H Perry Point Lead Survey Summary Report_11-14-2013.pdf","kind":"file","mime_type":".pdf","size_bytes":921632,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/588d3b4106ef438ab7ee409f3e84fed7/download","mirrored":false},{"resource_id":"8313afb619e048bab57f54fa4d79b82b","name":"512A5-25-003 23H ACM Data.xlsx","kind":"file","mime_type":".xlsx","size_bytes":204005,"posted_at":"2025-02-20T21:10:15.755Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8313afb619e048bab57f54fa4d79b82b/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24525C0073_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24525C0073_3600_-NONE-_-NONE-/","piid":"36C24525C0073","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"F8H2CBKK9FG8","recipient_name":"JRG PRECISION CONSTRUCTION, LLC","recipient_uei":"F8H2CBKK9FG8","recipient_cage":"9PZW9","recipient_city":"OWINGS","recipient_state":"MD","sub_name":"Department of Veterans Affairs","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","office_key":"o-36C245","first_action_date":"2025-03-18","last_action_date":"2025-08-07","actions":2,"obligated":"102686.27","current_total_value":"102686.27","potential_total_value":"102686.27","naics":"236220","psc":"Z2DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":6,"description":"REPAIR 23H FIRE DAMAGE AT PERRY POINT","method":"piid","confidence":"high","evidence":["award number 36C24525C0073 equals the contract number","same awarding office 36C245"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"W912BU27RA009","latest_notice_id":"b75232e01627477ba024adc55fa2e5e9","title":"Chesapeake and Delaware (C and D) Canal Building Replacement Project.","solicitation_number":"W912BU27RA009","notice_type":"p","first_type":"p","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BU","office_name":"W2SD ENDIST PHILADELPHIA","naics":"236220","psc":"Y1EB","set_aside":"SBA","state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"815 BETHEL RD, CHESAPEAKE CITY, MD 21915","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"75N99027R00002","latest_notice_id":"240c2aaf26d34ed7b201db3ff5cc712c","title":"NIH MULTIPLE-AWARD CONSTRUCTION CONTRACT (MACC) FOR GENERAL CONSTRUCTION SERVICES","solicitation_number":"75N99027R00002","notice_type":"o","first_type":"p","first_posted":"2026-10-13","last_posted":"2026-11-19","notices":4,"due_at":"2026-12-15T19:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N990","office_name":"NIH A E CONSTRUCTION","naics":"236220","psc":"Y1JZ","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C77626R0118","latest_notice_id":"f254169aa279439cba42e57fa1ec5c2f","title":"Y1DA--512A5-22-700 | EHRM Infra Upgrades | Perry Point, MD CO: Samantha Mihaila CS: Ric Sochor","solicitation_number":"36C77626R0118","notice_type":"o","first_type":"p","first_posted":"2026-10-21","last_posted":"2026-11-18","notices":2,"due_at":"2027-01-06T20:00:00Z","due_date":"2027-01-06","closes_at":"2027-01-06T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C776","office_name":"PCAC (36C776)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"MD","county":"24015","county_name":"Cecil County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":194,"indexable":false}