{"canonical":"https://sealedbidder.com/opportunities/36c24426q0937","key":"36C24426Q0937","url":"https://sealedbidder.com/opportunities/36c24426q0937","title":"6515--Inhalation Exposure System Pittsburgh Research (PACT Act)","solicitation_number":"36C24426Q0937","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-03T20:00:00Z","first_posted":"2026-09-01","last_posted":"2026-09-01","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"541714","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"25812015add54f6f86c3da0d1310617e","title":"6515--Inhalation Exposure System Pittsburgh Research (PACT Act)","solicitation_number":"36C24426Q0937","notice_type":"s","base_type":"s","posted":"2026-09-01","posted_at":"2026-09-01T18:29:33.521Z","due_at":"2026-09-03T20:00:00Z","due_date":"2026-09-03","cancelled":false,"archived":true,"archive_date":"2026-09-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/25812015add54f6f86c3da0d1310617e/view","enriched":true,"history":[{"index":3,"title":"6515--Inhalation Exposure System Pittsburgh Research (PACT Act)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-01T18:29:33.521Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"25812015add54f6f86c3da0d1310617e","solicitation_number":"36C24426Q0937"}]}],"latest_notice_id":"25812015add54f6f86c3da0d1310617e","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-09-01","posted_at":"2026-09-01T18:29:33.521Z","created_at":"2026-09-01T18:29:30.872Z","modified_at":"2026-09-13T05:07:31.895Z","response_deadline":{"raw":"2026-09-03T16:00:00-04:00","utc":"2026-09-03T20:00:00Z","date":"2026-09-03","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/25812015add54f6f86c3da0d1310617e/view"},"naics":{"codes":["541714"],"primary":"541714"},"title":"6515--Inhalation Exposure System Pittsburgh Research (PACT Act)","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Inhalation Exposure System Pittsburgh Research (PACT Act)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-01T18:29:33.521Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"25812015add54f6f86c3da0d1310617e","solicitation_number":"36C24426Q0937"}],"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-841-7191","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"25812015add54f6f86c3da0d1310617e","lineage_id":"25812015add54f6f86c3da0d1310617e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T04:12:46.178195765Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"63053688a1d7739512ef9acb7275317f26718a598cfe50c67a3622e3751ba3ed","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-24T04:12:46.178195765Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"2\n\nSTATEMENT OF WORK \nContract Title: \nIEStechno Exposure System Purchase Contract at VA Pittsburgh Healthcare System (VAPHS).\nBackground: \nThe VA Pittsburgh Healthcare System (VAPHS) is in need of an inhalation exposure system to support controlled experimental exposure studies involving aerosolized particulates, vapors, and gaseous agents. The system shall be designed to enable reproducible delivery of defined aerosolized or gaseous exposures to in vivo animal models and in vitro cellular systems under controlled laboratory conditions. This shared research resource will enhance the capability of investigators at VAPHS to conduct translational and preclinical studies related to respiratory health, toxicology, military exposure research, environmental exposure science, and related biomedical research areas.\nScope:\nThe Contractor shall construct and install a modular inhalation exposure system capable of providing reliable and reproducible exposure conditions suitable for a variety of inhalation research applications, including aerosolized particulates, vapors, and gaseous agents, while supporting appropriate environmental control, monitoring, and safety requirements. The inhalation exposure system shall be capable of supporting both in vivo animal models and in vitro cellular, as required by specific study designs, as well as include integrated controls for airflow, temperature, humidity, aerosol/gas concentration monitoring, and exposure duration. The system shall also incorporate multiple engineering and procedural safety features intended to minimize risk and ensure compliance with institutional safety standards.\nDeliverables/Technical Requirements\nThe inhalation exposure system shall include:\nBase Toxicant Inhalation Exposure System (BExp1): This system includes: \nCube 150 Stainless-Steel Exposure Chamber to hold up to 12 rats or 36 mice \nAir-cleaning System Module (pressure regulator, air dryer, carbon filter and HEPA filter)\nGenerator Mass Flow Controller\nDiluent Mass Flow Controller\nGravimetric Sampling Mass Flow Controller\nMass Flow Controller Hub\nTemperature and Humidity Probe\nCO2 Monitor\nUSB Hub\n24 Volt Power Supply\nExhaust Mass Flow Controller\nExhaust HEPA Filter with Housing\nExhaust Activated Carbon Filter with Housing\nGenerator Pressure Transducer\nExposure Chamber Pressure Transducer\nCustom Stainless-Steel Aerosol and Gas Disperser\nLight Scattering Device that estimates the real-time mass concentration of the aerosols in the exposure chamber\nPhoto Ionization Detector to estimate the real-time volatile organic compound gas levels in the exposure chamber\nEmergency Shut Down Button\nMulti-function input/output board that interfaces with the computer to digitize analog signals\nLaptop computer\nCustom Base Software that acts as a graphical user interface to monitor, control and record exposure variables\nAll associated cables and tubing -Instruction manual\nLow-Noise Exhaust Vacuum Pump with Sound Shield (VPump)\nAutomatic Super Humidifier Controller for the Toxicant Inhalation Exposure System (HumLab1): \nCell Exposure System (CellExpo1): \nDry Powder Acoustical Aerosol Generator (HP AG): \nSmall High Pressure Acoustical Generator (HP-AG-0.5): \nHigh Pressure Nebuilzer Liquid Aerosol Generator (Neb1): \nJet Fuel Liquid Combustion Generator (LiqComG ): \nModification to allow Jet Fuel Liquid Combustion Generator to also function as a Heated Vapor Generator (VapMod1): \nE-Cig Puff Vape Generator (Puff): \nBase Control Inhalation Exposure System (Expo1):\nAutomatic Control Inhalation Exposure System (AutoCon): \nHeating and Cooling System for the Control Inhalation Exposure Systemm(ChHeCo2): \nAutomatic Super Humidifier Controller for the Control Inhalation Exposure System (HumLab1): \nCustom Stainless Steel Mouse Cage for 36 Individually Housed Mice (MCAGE1):\nCustom Stainless Steel Rat Cage for 12 Individually Housed Rats (RCAGE1):\nSystem installation at customer site (INST1): \nSystem use training (TRN1):\nAnnual Service Contract (ServQuad): Contractor Requirements: \nSystem Delivery and Installation\nThe Contractor shall deliver all system components to the designated laboratory site and perform complete installation. Installation shall include assembly, integration of modules, connection to facility utilities as required, and verification of full system functionality and operational readiness.\nSystem Validation and Performance Verification\nThe Contractor shall perform full system validation, including: functional verification of all system components; calibration of sensors and monitoring devices; validation of aerosol, gas, and vapor generation performance; confirmation of exposure control stability and reproducibility; and demonstration of proper operation of all safety and control systems\nTraining Requirements\nThe Contractor shall provide comprehensive on-site training for end users. Training shall include three (3) full days of instruction covering system operation, maintenance, safety procedures, troubleshooting, and data acquisition/analysis. Unlimited remote support (email and telephone) shall also be provided.\nPreventative Maintenance and Service Support\nThe Contractor shall provide an annual service agreement including four (4) scheduled on-site maintenance visits per year. During each visit, preventative maintenance will be performed including filter replacement, sensor calibration, replacement of disposable parts showing wear, and updates/tuning of exposure control systems. Any equipment issues or failures will be identified during these visits; however, the cost of replacing any damaged or non-functional equipment will be the responsibility of the Customer.\nDocumentation Requirements\nThe contractor shall provide full system documentation, including operation manuals, maintenance procedures, calibration protocols, and software user guides.\nSafety and Compliance\nThe system shall comply with applicable institutional, occupational, and laboratory safety standards and regulations. The Contractor shall ensure the system is suitable for operation in controlled inhalation exposure research environments involving aerosols, gases, vapors, and other experimental toxicants.\nOther Requirements\nService Hours\nThe Contractor shall provide all required  on-site  services within the normal business hours (8:00 AM to 5:00 PM (EST) M-F), excluding holidays. Work performed outside the normal hours of coverage must be pre-approved by the Technical POC.\nThe Contractor representatives must be escorted at all times while on VA premises. \nIdentification and Parking\nA compliant ID badge must be worn by the Contractor representatives at all times while on VA premises. \nIt is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police-Security Service. VAPHS will not invalidate or make reimbursement for parking violations of the contractor under any conditions.\nSmoking \nAll VA Pittsburgh property is smoke-free. Contractor personnel will comply with VA Pittsburgh smoking policies. Violations will result in a warning and possible citation.\nPeriod of Performance: Six (6) months from date of award \nPlace of Performance: \nVA Pittsburgh Healthcare System (VAPHS)\nResearch Office Building B30\n4071-4089 University Dr. C\nPittsburgh, PA 15219","text":"2\n\nSTATEMENT OF WORK\nContract Title:\nIEStechno Exposure System Purchase Contract at VA Pittsburgh Healthcare System (VAPHS).\nBackground:\nThe VA Pittsburgh Healthcare System (VAPHS) is in need of an inhalation exposure system to support controlled experimental exposure studies involving aerosolized particulates, vapors, and gaseous agents. The system shall be designed to enable reproducible delivery of defined aerosolized or gaseous exposures to in vivo animal models and in vitro cellular systems under controlled laboratory conditions. This shared research resource will enhance the capability of investigators at VAPHS to conduct translational and preclinical studies related to respiratory health, toxicology, military exposure research, environmental exposure science, and related biomedical research areas.\nScope:\nThe Contractor shall construct and install a modular inhalation exposure system capable of providing reliable and reproducible exposure conditions suitable for a variety of inhalation research applications, including aerosolized particulates, vapors, and gaseous agents, while supporting appropriate environmental control, monitoring, and safety requirements. The inhalation exposure system shall be capable of supporting both in vivo animal models and in vitro cellular, as required by specific study designs, as well as include integrated controls for airflow, temperature, humidity, aerosol/gas concentration monitoring, and exposure duration. The system shall also incorporate multiple engineering and procedural safety features intended to minimize risk and ensure compliance with institutional safety standards.\nDeliverables/Technical Requirements\nThe inhalation exposure system shall include:\nBase Toxicant Inhalation Exposure System (BExp1): This system includes:\nCube 150 Stainless-Steel Exposure Chamber to hold up to 12 rats or 36 mice\nAir-cleaning System Module (pressure regulator, air dryer, carbon filter and HEPA filter)\nGenerator Mass Flow Controller\nDiluent Mass Flow Controller\nGravimetric Sampling Mass Flow Controller\nMass Flow Controller Hub\nTemperature and Humidity Probe\nCO2 Monitor\nUSB Hub\n24 Volt Power Supply\nExhaust Mass Flow Controller\nExhaust HEPA Filter with Housing\nExhaust Activated Carbon Filter with Housing\nGenerator Pressure Transducer\nExposure Chamber Pressure Transducer\nCustom Stainless-Steel Aerosol and Gas Disperser\nLight Scattering Device that estimates the real-time mass concentration of the aerosols in the exposure chamber\nPhoto Ionization Detector to estimate the real-time volatile organic compound gas levels in the exposure chamber\nEmergency Shut Down Button\nMulti-function input/output board that interfaces with the computer to digitize analog signals\nLaptop computer\nCustom Base Software that acts as a graphical user interface to monitor, control and record exposure variables\nAll associated cables and tubing -Instruction manual\nLow-Noise Exhaust Vacuum Pump with Sound Shield (VPump)\nAutomatic Super Humidifier Controller for the Toxicant Inhalation Exposure System (HumLab1):\nCell Exposure System (CellExpo1):\nDry Powder Acoustical Aerosol Generator (HP AG):\nSmall High Pressure Acoustical Generator (HP-AG-0.5):\nHigh Pressure Nebuilzer Liquid Aerosol Generator (Neb1):\nJet Fuel Liquid Combustion Generator (LiqComG ):\nModification to allow Jet Fuel Liquid Combustion Generator to also function as a Heated Vapor Generator (VapMod1):\nE-Cig Puff Vape Generator (Puff):\nBase Control Inhalation Exposure System (Expo1):\nAutomatic Control Inhalation Exposure System (AutoCon):\nHeating and Cooling System for the Control Inhalation Exposure Systemm(ChHeCo2):\nAutomatic Super Humidifier Controller for the Control Inhalation Exposure System (HumLab1):\nCustom Stainless Steel Mouse Cage for 36 Individually Housed Mice (MCAGE1):\nCustom Stainless Steel Rat Cage for 12 Individually Housed Rats (RCAGE1):\nSystem installation at customer site (INST1):\nSystem use training (TRN1):\nAnnual Service Contract (ServQuad): Contractor Requirements:\nSystem Delivery and Installation\nThe Contractor shall deliver all system components to the designated laboratory site and perform complete installation. Installation shall include assembly, integration of modules, connection to facility utilities as required, and verification of full system functionality and operational readiness.\nSystem Validation and Performance Verification\nThe Contractor shall perform full system validation, including: functional verification of all system components; calibration of sensors and monitoring devices; validation of aerosol, gas, and vapor generation performance; confirmation of exposure control stability and reproducibility; and demonstration of proper operation of all safety and control systems\nTraining Requirements\nThe Contractor shall provide comprehensive on-site training for end users. Training shall include three (3) full days of instruction covering system operation, maintenance, safety procedures, troubleshooting, and data acquisition/analysis. Unlimited remote support (email and telephone) shall also be provided.\nPreventative Maintenance and Service Support\nThe Contractor shall provide an annual service agreement including four (4) scheduled on-site maintenance visits per year. During each visit, preventative maintenance will be performed including filter replacement, sensor calibration, replacement of disposable parts showing wear, and updates/tuning of exposure control systems. Any equipment issues or failures will be identified during these visits; however, the cost of replacing any damaged or non-functional equipment will be the responsibility of the Customer.\nDocumentation Requirements\nThe contractor shall provide full system documentation, including operation manuals, maintenance procedures, calibration protocols, and software user guides.\nSafety and Compliance\nThe system shall comply with applicable institutional, occupational, and laboratory safety standards and regulations. The Contractor shall ensure the system is suitable for operation in controlled inhalation exposure research environments involving aerosols, gases, vapors, and other experimental toxicants.\nOther Requirements\nService Hours\nThe Contractor shall provide all required on-site services within the normal business hours (8:00 AM to 5:00 PM (EST) M-F), excluding holidays. Work performed outside the normal hours of coverage must be pre-approved by the Technical POC.\nThe Contractor representatives must be escorted at all times while on VA premises.\nIdentification and Parking\nA compliant ID badge must be worn by the Contractor representatives at all times while on VA premises.\nIt is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police-Security Service. VAPHS will not invalidate or make reimbursement for parking violations of the contractor under any conditions.\nSmoking\nAll VA Pittsburgh property is smoke-free. Contractor personnel will comply with VA Pittsburgh smoking policies. Violations will result in a warning and possible citation.\nPeriod of Performance: Six (6) months from date of award\nPlace of Performance:\nVA Pittsburgh Healthcare System (VAPHS)\nResearch Office Building B30\n4071-4089 University Dr. C\nPittsburgh, PA 15219","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24426Q0937","product_service_code":"6515"}],"due_at":"2026-09-03T20:00:00Z","due_date":"2026-09-03","closes_at":"2026-09-03T20:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-24T04:24:26.592861Z","principal_notice_id":"25812015add54f6f86c3da0d1310617e","description":{"text":"2\n\nSTATEMENT OF WORK\nContract Title:\nIEStechno Exposure System Purchase Contract at VA Pittsburgh Healthcare System (VAPHS).\nBackground:\nThe VA Pittsburgh Healthcare System (VAPHS) is in need of an inhalation exposure system to support controlled experimental exposure studies involving aerosolized particulates, vapors, and gaseous agents. The system shall be designed to enable reproducible delivery of defined aerosolized or gaseous exposures to in vivo animal models and in vitro cellular systems under controlled laboratory conditions. This shared research resource will enhance the capability of investigators at VAPHS to conduct translational and preclinical studies related to respiratory health, toxicology, military exposure research, environmental exposure science, and related biomedical research areas.\nScope:\nThe Contractor shall construct and install a modular inhalation exposure system capable of providing reliable and reproducible exposure conditions suitable for a variety of inhalation research applications, including aerosolized particulates, vapors, and gaseous agents, while supporting appropriate environmental control, monitoring, and safety requirements. The inhalation exposure system shall be capable of supporting both in vivo animal models and in vitro cellular, as required by specific study designs, as well as include integrated controls for airflow, temperature, humidity, aerosol/gas concentration monitoring, and exposure duration. The system shall also incorporate multiple engineering and procedural safety features intended to minimize risk and ensure compliance with institutional safety standards.\nDeliverables/Technical Requirements\nThe inhalation exposure system shall include:\nBase Toxicant Inhalation Exposure System (BExp1): This system includes:\nCube 150 Stainless-Steel Exposure Chamber to hold up to 12 rats or 36 mice\nAir-cleaning System Module (pressure regulator, air dryer, carbon filter and HEPA filter)\nGenerator Mass Flow Controller\nDiluent Mass Flow Controller\nGravimetric Sampling Mass Flow Controller\nMass Flow Controller Hub\nTemperature and Humidity Probe\nCO2 Monitor\nUSB Hub\n24 Volt Power Supply\nExhaust Mass Flow Controller\nExhaust HEPA Filter with Housing\nExhaust Activated Carbon Filter with Housing\nGenerator Pressure Transducer\nExposure Chamber Pressure Transducer\nCustom Stainless-Steel Aerosol and Gas Disperser\nLight Scattering Device that estimates the real-time mass concentration of the aerosols in the exposure chamber\nPhoto Ionization Detector to estimate the real-time volatile organic compound gas levels in the exposure chamber\nEmergency Shut Down Button\nMulti-function input/output board that interfaces with the computer to digitize analog signals\nLaptop computer\nCustom Base Software that acts as a graphical user interface to monitor, control and record exposure variables\nAll associated cables and tubing -Instruction manual\nLow-Noise Exhaust Vacuum Pump with Sound Shield (VPump)\nAutomatic Super Humidifier Controller for the Toxicant Inhalation Exposure System (HumLab1):\nCell Exposure System (CellExpo1):\nDry Powder Acoustical Aerosol Generator (HP AG):\nSmall High Pressure Acoustical Generator (HP-AG-0.5):\nHigh Pressure Nebuilzer Liquid Aerosol Generator (Neb1):\nJet Fuel Liquid Combustion Generator (LiqComG ):\nModification to allow Jet Fuel Liquid Combustion Generator to also function as a Heated Vapor Generator (VapMod1):\nE-Cig Puff Vape Generator (Puff):\nBase Control Inhalation Exposure System (Expo1):\nAutomatic Control Inhalation Exposure System (AutoCon):\nHeating and Cooling System for the Control Inhalation Exposure Systemm(ChHeCo2):\nAutomatic Super Humidifier Controller for the Control Inhalation Exposure System (HumLab1):\nCustom Stainless Steel Mouse Cage for 36 Individually Housed Mice (MCAGE1):\nCustom Stainless Steel Rat Cage for 12 Individually Housed Rats (RCAGE1):\nSystem installation at customer site (INST1):\nSystem use training (TRN1):\nAnnual Service Contract (ServQuad): Contractor Requirements:\nSystem Delivery and Installation\nThe Contractor shall deliver all system components to the designated laboratory site and perform complete installation. Installation shall include assembly, integration of modules, connection to facility utilities as required, and verification of full system functionality and operational readiness.\nSystem Validation and Performance Verification\nThe Contractor shall perform full system validation, including: functional verification of all system components; calibration of sensors and monitoring devices; validation of aerosol, gas, and vapor generation performance; confirmation of exposure control stability and reproducibility; and demonstration of proper operation of all safety and control systems\nTraining Requirements\nThe Contractor shall provide comprehensive on-site training for end users. Training shall include three (3) full days of instruction covering system operation, maintenance, safety procedures, troubleshooting, and data acquisition/analysis. Unlimited remote support (email and telephone) shall also be provided.\nPreventative Maintenance and Service Support\nThe Contractor shall provide an annual service agreement including four (4) scheduled on-site maintenance visits per year. During each visit, preventative maintenance will be performed including filter replacement, sensor calibration, replacement of disposable parts showing wear, and updates/tuning of exposure control systems. Any equipment issues or failures will be identified during these visits; however, the cost of replacing any damaged or non-functional equipment will be the responsibility of the Customer.\nDocumentation Requirements\nThe contractor shall provide full system documentation, including operation manuals, maintenance procedures, calibration protocols, and software user guides.\nSafety and Compliance\nThe system shall comply with applicable institutional, occupational, and laboratory safety standards and regulations. The Contractor shall ensure the system is suitable for operation in controlled inhalation exposure research environments involving aerosols, gases, vapors, and other experimental toxicants.\nOther Requirements\nService Hours\nThe Contractor shall provide all required on-site services within the normal business hours (8:00 AM to 5:00 PM (EST) M-F), excluding holidays. Work performed outside the normal hours of coverage must be pre-approved by the Technical POC.\nThe Contractor representatives must be escorted at all times while on VA premises.\nIdentification and Parking\nA compliant ID badge must be worn by the Contractor representatives at all times while on VA premises.\nIt is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police-Security Service. VAPHS will not invalidate or make reimbursement for parking violations of the contractor under any conditions.\nSmoking\nAll VA Pittsburgh property is smoke-free. Contractor personnel will comply with VA Pittsburgh smoking policies. Violations will result in a warning and possible citation.\nPeriod of Performance: Six (6) months from date of award\nPlace of Performance:\nVA Pittsburgh Healthcare System (VAPHS)\nResearch Office Building B30\n4071-4089 University Dr. C\nPittsburgh, PA 15219","html":"2\n\nSTATEMENT OF WORK \nContract Title: \nIEStechno Exposure System Purchase Contract at VA Pittsburgh Healthcare System (VAPHS).\nBackground: \nThe VA Pittsburgh Healthcare System (VAPHS) is in need of an inhalation exposure system to support controlled experimental exposure studies involving aerosolized particulates, vapors, and gaseous agents. The system shall be designed to enable reproducible delivery of defined aerosolized or gaseous exposures to in vivo animal models and in vitro cellular systems under controlled laboratory conditions. This shared research resource will enhance the capability of investigators at VAPHS to conduct translational and preclinical studies related to respiratory health, toxicology, military exposure research, environmental exposure science, and related biomedical research areas.\nScope:\nThe Contractor shall construct and install a modular inhalation exposure system capable of providing reliable and reproducible exposure conditions suitable for a variety of inhalation research applications, including aerosolized particulates, vapors, and gaseous agents, while supporting appropriate environmental control, monitoring, and safety requirements. The inhalation exposure system shall be capable of supporting both in vivo animal models and in vitro cellular, as required by specific study designs, as well as include integrated controls for airflow, temperature, humidity, aerosol/gas concentration monitoring, and exposure duration. The system shall also incorporate multiple engineering and procedural safety features intended to minimize risk and ensure compliance with institutional safety standards.\nDeliverables/Technical Requirements\nThe inhalation exposure system shall include:\nBase Toxicant Inhalation Exposure System (BExp1): This system includes: \nCube 150 Stainless-Steel Exposure Chamber to hold up to 12 rats or 36 mice \nAir-cleaning System Module (pressure regulator, air dryer, carbon filter and HEPA filter)\nGenerator Mass Flow Controller\nDiluent Mass Flow Controller\nGravimetric Sampling Mass Flow Controller\nMass Flow Controller Hub\nTemperature and Humidity Probe\nCO2 Monitor\nUSB Hub\n24 Volt Power Supply\nExhaust Mass Flow Controller\nExhaust HEPA Filter with Housing\nExhaust Activated Carbon Filter with Housing\nGenerator Pressure Transducer\nExposure Chamber Pressure Transducer\nCustom Stainless-Steel Aerosol and Gas Disperser\nLight Scattering Device that estimates the real-time mass concentration of the aerosols in the exposure chamber\nPhoto Ionization Detector to estimate the real-time volatile organic compound gas levels in the exposure chamber\nEmergency Shut Down Button\nMulti-function input/output board that interfaces with the computer to digitize analog signals\nLaptop computer\nCustom Base Software that acts as a graphical user interface to monitor, control and record exposure variables\nAll associated cables and tubing -Instruction manual\nLow-Noise Exhaust Vacuum Pump with Sound Shield (VPump)\nAutomatic Super Humidifier Controller for the Toxicant Inhalation Exposure System (HumLab1): \nCell Exposure System (CellExpo1): \nDry Powder Acoustical Aerosol Generator (HP AG): \nSmall High Pressure Acoustical Generator (HP-AG-0.5): \nHigh Pressure Nebuilzer Liquid Aerosol Generator (Neb1): \nJet Fuel Liquid Combustion Generator (LiqComG ): \nModification to allow Jet Fuel Liquid Combustion Generator to also function as a Heated Vapor Generator (VapMod1): \nE-Cig Puff Vape Generator (Puff): \nBase Control Inhalation Exposure System (Expo1):\nAutomatic Control Inhalation Exposure System (AutoCon): \nHeating and Cooling System for the Control Inhalation Exposure Systemm(ChHeCo2): \nAutomatic Super Humidifier Controller for the Control Inhalation Exposure System (HumLab1): \nCustom Stainless Steel Mouse Cage for 36 Individually Housed Mice (MCAGE1):\nCustom Stainless Steel Rat Cage for 12 Individually Housed Rats (RCAGE1):\nSystem installation at customer site (INST1): \nSystem use training (TRN1):\nAnnual Service Contract (ServQuad): Contractor Requirements: \nSystem Delivery and Installation\nThe Contractor shall deliver all system components to the designated laboratory site and perform complete installation. Installation shall include assembly, integration of modules, connection to facility utilities as required, and verification of full system functionality and operational readiness.\nSystem Validation and Performance Verification\nThe Contractor shall perform full system validation, including: functional verification of all system components; calibration of sensors and monitoring devices; validation of aerosol, gas, and vapor generation performance; confirmation of exposure control stability and reproducibility; and demonstration of proper operation of all safety and control systems\nTraining Requirements\nThe Contractor shall provide comprehensive on-site training for end users. Training shall include three (3) full days of instruction covering system operation, maintenance, safety procedures, troubleshooting, and data acquisition/analysis. Unlimited remote support (email and telephone) shall also be provided.\nPreventative Maintenance and Service Support\nThe Contractor shall provide an annual service agreement including four (4) scheduled on-site maintenance visits per year. During each visit, preventative maintenance will be performed including filter replacement, sensor calibration, replacement of disposable parts showing wear, and updates/tuning of exposure control systems. Any equipment issues or failures will be identified during these visits; however, the cost of replacing any damaged or non-functional equipment will be the responsibility of the Customer.\nDocumentation Requirements\nThe contractor shall provide full system documentation, including operation manuals, maintenance procedures, calibration protocols, and software user guides.\nSafety and Compliance\nThe system shall comply with applicable institutional, occupational, and laboratory safety standards and regulations. The Contractor shall ensure the system is suitable for operation in controlled inhalation exposure research environments involving aerosols, gases, vapors, and other experimental toxicants.\nOther Requirements\nService Hours\nThe Contractor shall provide all required  on-site  services within the normal business hours (8:00 AM to 5:00 PM (EST) M-F), excluding holidays. Work performed outside the normal hours of coverage must be pre-approved by the Technical POC.\nThe Contractor representatives must be escorted at all times while on VA premises. \nIdentification and Parking\nA compliant ID badge must be worn by the Contractor representatives at all times while on VA premises. \nIt is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police-Security Service. VAPHS will not invalidate or make reimbursement for parking violations of the contractor under any conditions.\nSmoking \nAll VA Pittsburgh property is smoke-free. Contractor personnel will comply with VA Pittsburgh smoking policies. Violations will result in a warning and possible citation.\nPeriod of Performance: Six (6) months from date of award \nPlace of Performance: \nVA Pittsburgh Healthcare System (VAPHS)\nResearch Office Building B30\n4071-4089 University Dr. C\nPittsburgh, PA 15219","origin":"detail"},"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-841-7191","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["541714"],"award":{"awardee":{}},"attachments":[{"resource_id":"1e9a71ce6bff4ce681b73a9a07b0cd43","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-09-01T18:29:33.521Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/pittsburgh-health-care/","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0072","latest_notice_id":"525908b124d04d13ac7905ddca2dc6d2","title":"Micro-Sized Scissor Lift","solicitation_number":"36C24427Q0072","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333924","psc":"3990","set_aside":null,"state":"PA","county":"42019","county_name":"Butler County","city":"4210464","city_name":"Butler","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"ARPAHSOL26164","latest_notice_id":"c00c844955844519851bf8e53cda9f01","title":"Simulation-augmented, Real-time Platform Adaptive Seamless Trials (SURPASS)","solicitation_number":"ARPA-H-SOL-26-164","notice_type":"o","first_type":"o","first_posted":"2026-09-30","last_posted":"2026-11-13","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N992","office_name":"ADVANCED RESEARCH PROJECTS AGENCY FOR HEALTH (ARPA-H)","naics":"541714","psc":"AN13","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Research and development (PSC AN13)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"DARPAPS26137","latest_notice_id":"ea1ade5831b545cc93affd13e79e7e0d","title":"Firefox","solicitation_number":"DARPA-PS-26-137","notice_type":"o","first_type":"o","first_posted":"2026-09-16","last_posted":"2026-11-06","notices":2,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AE","sub_name":"DEFENSE ADVANCED RESEARCH PROJECTS AGENCY (DARPA)","office_key":"o-HR0011","office_name":"DEF ADVANCED RESEARCH PROJECTS AGCY","naics":"541714","psc":"AC12","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Research and development (PSC AC12)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"75N93027R00003","latest_notice_id":"48e64180d8534cc19ddbaf03306a366c","title":"Pre-Clinical Models of Infectious Diseases","solicitation_number":"75N93027R00003","notice_type":"p","first_type":"p","first_posted":"2026-10-19","last_posted":"2026-10-19","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N930","office_name":"NATIONAL INSTITUTES OF HEALTH NIAID","naics":"541714","psc":"AN11","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Research and development (PSC AN11)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-20T03:49:45.611939Z"}],"similar_open_total":13,"indexable":false}