{"canonical":"https://sealedbidder.com/opportunities/36c24426q0913","key":"36C24426Q0913","url":"https://sealedbidder.com/opportunities/36c24426q0913","title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","solicitation_number":"36C24426Q0913","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-27T10:00:00Z","first_posted":"2026-08-19","last_posted":"2026-08-19","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"811210","psc":"J065","set_aside":null,"place_state":"PA","place_scope":"site","site":null,"place_state_source":"site","place_evidence":"THE GOVERNMENT S DISCRETION. THE LEBANON VA MEDICAL CENTER","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"41c93efd1800449dbb5d84a8061071f6","title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","solicitation_number":"36C24426Q0913","notice_type":"s","base_type":"s","posted":"2026-08-19","posted_at":"2026-08-19T16:57:37.958Z","due_at":"2026-08-27T10:00:00Z","due_date":"2026-08-27","cancelled":false,"archived":true,"archive_date":"2026-09-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/41c93efd1800449dbb5d84a8061071f6/view","enriched":true,"history":[{"index":3,"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-19T16:57:37.958Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"41c93efd1800449dbb5d84a8061071f6","solicitation_number":"36C24426Q0913"}]},{"notice_id":"62ea91e90db1482995585b5d2a0ffe63","title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","solicitation_number":"36C24426Q0913","notice_type":"s","base_type":"s","posted":"2026-08-19","posted_at":"2026-08-19T16:57:38.533Z","due_at":"2026-08-27T10:00:00Z","due_date":"2026-08-27","cancelled":false,"archived":true,"archive_date":"2026-09-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/62ea91e90db1482995585b5d2a0ffe63/view","enriched":true,"history":[{"index":3,"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-19T16:57:38.533Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"62ea91e90db1482995585b5d2a0ffe63","solicitation_number":"36C24426Q0913"}]}],"latest_notice_id":"62ea91e90db1482995585b5d2a0ffe63","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-19","posted_at":"2026-08-19T16:57:37.958Z","created_at":"2026-08-19T16:57:35.732Z","modified_at":"2026-09-10T05:07:48.881Z","response_deadline":{"raw":"2026-08-27T06:00:00-04:00","utc":"2026-08-27T10:00:00Z","date":"2026-08-27","time":"06:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/41c93efd1800449dbb5d84a8061071f6/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-19T16:57:37.958Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"41c93efd1800449dbb5d84a8061071f6","solicitation_number":"36C24426Q0913"}],"contacts":[{"name":"Jefferson Mann","role":"primary","email":"jefferson.mann@va.gov","phone":"717-202-5456","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"41c93efd1800449dbb5d84a8061071f6","lineage_id":"41c93efd1800449dbb5d84a8061071f6","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T13:32:46.155854817Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"a8804f479f533e7ee6984bd8acbd4d68db466d557e3e621831456c8aded79cbd","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-24T13:32:46.155854817Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"NOTICE OF INTENT TO SOLE SOURCE: \nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS. \nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information: \n1. Company Name\n2. SAM UEI number \n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. \nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. \n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time.  Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted. \n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n \nSTATEMENT OF WORK\n\nPreventative Maintenance Services \nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous.  This equipment currently does not connect to the VA network.  The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair: \nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician. \nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC. \nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.  \nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost. \nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work. \nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment. \nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC. \nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC \nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays. \nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work. \nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts. \nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","text":"NOTICE OF INTENT TO SOLE SOURCE:\nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS.\nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information:\n1. Company Name\n2. SAM UEI number\n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification.\n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time. Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted.\n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n\nSTATEMENT OF WORK\n\nPreventative Maintenance Services\nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous. This equipment currently does not connect to the VA network. The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair:\nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician.\nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC.\nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.\nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost.\nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work.\nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment.\nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC.\nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC\nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays.\nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work.\nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts.\nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24426Q0913","product_service_code":"J065"},{"award":{"awardee":{}},"dates":{"posted":"2026-08-19","posted_at":"2026-08-19T16:57:38.533Z","created_at":"2026-08-19T16:57:36.266Z","modified_at":"2026-09-10T05:07:48.881Z","response_deadline":{"raw":"2026-08-27T06:00:00-04:00","utc":"2026-08-27T10:00:00Z","date":"2026-08-27","time":"06:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/62ea91e90db1482995585b5d2a0ffe63/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--Ventana Slide Stainer Scanner Equipment Preventative Maintenance and Repair","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-19T16:57:38.533Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"62ea91e90db1482995585b5d2a0ffe63","solicitation_number":"36C24426Q0913"}],"contacts":[{"name":"Jefferson Mann","role":"primary","email":"jefferson.mann@va.gov","phone":"717-202-5456","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"62ea91e90db1482995585b5d2a0ffe63","lineage_id":"62ea91e90db1482995585b5d2a0ffe63","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T13:44:01.755160723Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"f73acef07b9a3f80f6dc9efb86a76302d93e233a15e164b2b736559a09e0d3ba","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-24T13:44:01.755160723Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"NOTICE OF INTENT TO SOLE SOURCE: \nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS. \nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information: \n1. Company Name\n2. SAM UEI number \n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. \nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. \n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time.  Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted. \n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n \nSTATEMENT OF WORK\n\nPreventative Maintenance Services \nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous.  This equipment currently does not connect to the VA network.  The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair: \nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician. \nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC. \nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.  \nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost. \nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work. \nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment. \nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC. \nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC \nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays. \nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work. \nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts. \nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","text":"NOTICE OF INTENT TO SOLE SOURCE:\nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS.\nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information:\n1. Company Name\n2. SAM UEI number\n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification.\n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time. Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted.\n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n\nSTATEMENT OF WORK\n\nPreventative Maintenance Services\nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous. This equipment currently does not connect to the VA network. The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair:\nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician.\nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC.\nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.\nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost.\nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work.\nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment.\nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC.\nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC\nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays.\nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work.\nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts.\nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24426Q0913","product_service_code":"J065"}],"due_at":"2026-08-27T10:00:00Z","due_date":"2026-08-27","closes_at":"2026-08-27T10:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"site","state_evidence":"THE GOVERNMENT S DISCRETION. THE LEBANON VA MEDICAL CENTER","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T08:44:04.547541Z","principal_notice_id":"62ea91e90db1482995585b5d2a0ffe63","description":{"text":"NOTICE OF INTENT TO SOLE SOURCE:\nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS.\nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information:\n1. Company Name\n2. SAM UEI number\n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification.\n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time. Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted.\n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n\nSTATEMENT OF WORK\n\nPreventative Maintenance Services\nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous. This equipment currently does not connect to the VA network. The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair:\nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician.\nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC.\nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.\nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost.\nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work.\nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment.\nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC.\nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC\nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays.\nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work.\nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts.\nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","html":"NOTICE OF INTENT TO SOLE SOURCE: \nIAW RFO FAR 5.101 this notice is to advise the public that The Department of Veterans Affairs, Regional Procurement Office East (RPOE), Network Contracting Office 4, intends to award a sole source, Firm-Fixed-Price contract pursuant to RFO FAR 12.102(a) to Roche Diagnostics Corp. located at 9115 Hague RD, Indianapolis, IN, 46256, for a base year with one (1) option year, exercisable at the Government s discretion. The Lebanon VA Medical Center (VAMC) requires service, maintenance, repairs, and software support DP 200 Slide Scanner and Benchmark Special Stainer to maintain operability of the Pathology Department s slide specimen analysis system.\n\n\nTHIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS or QUOTATIONS. \nResponsible sources that believe they can meet the requirements may give written notification by submitting capability information that clearly demonstrates the capability to perform the required work and applicable certifications/licenses for the Hardware/Software. Capability information is required prior to the response due date and time, to establish the ability of the source to meet this requirement. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address.\n\nResponses must include following information: \n1. Company Name\n2. SAM UEI number \n3. Company s address\n4. Point of Contact information (title, phone number and email address)\n5. Business size.\n\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. \nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. \n\nResponses are due by 6:00 am ET, Thursday, August 27, 2026. No submissions will be accepted after this date and time.  Responses shall be submitted via email to jefferson.mann@va.gov. Telephone inquiries will not be accepted. \n\nThe NAICS code for this acquisition is 811210 and the size standard is $34 Million.\n \nSTATEMENT OF WORK\n\nPreventative Maintenance Services \nROCHE Special Stainer and Scanner\nLebanon VA Medical Center\n1700 S Lincoln Ave, Lebanon PA 17025\n\nBackground: The ROCHE equipment is used to process specimens for pathological analysis. Due to the complexity of the system, it requires annual preventive maintenance that includes ongoing hardware and software troubleshooting and technical support as part of the service during normal business hours. All service and repair is to be completed by trained personnel using manufacturer approved parts and specifications at no additional cost. The reliable and accurate operation of this equipment is considered critical to the health of patients.\n\nGeneral Requirements: The contractor shall provide service, maintenance, repairs, and software to ensure the full operational capability of the DP 200 Slide Scanner and Benchmark Special Stainer in accordance with manufacturer s and/or VA s performance specifications, whichever is the most rigorous.  This equipment currently does not connect to the VA network.  The contractor shall be responsible for all materials including supplies, parts, software, labor, travel, and shipping & handling necessary to complete all services on the following equipment:\n\nBenchMark Special Stainer #6657389001\nDP200 Scanner #8303924001\n\nPreventative Maintenance and Repair: \nThe Contractor shall perform a minimum of (1) preventative maintenance (PM) visit per contract year to ensure that the equipment listed performs in accordance with the specifications.\nPreventive maintenance will be scheduled at least one week in advance with Program POC to minimize the impact on patient care. Sufficient time shall be allotted during preventative maintenance visit to permit a thorough inspection of the overall system by technician. \nAll exceptions to the preventive maintenance schedule and/or procedures shall be approved in advance by the Program POC. \nContractor shall provide unlimited telephone technical support, labor, travel and parts, to maintain system operation.  \nAll work shall be performed by competent, experienced ROCHE technicians qualified to work on the specified equipment in accordance with manufacturer s recommendations.\nMaterials such as lubricants, fluids, cleaning supplies, services, manuals, or tools required for the Contractor to successfully complete scheduled PM shall be provided by the Contractor and are included within this contract at no additional cost. \nThe Contractor shall prepare and submit a written report containing findings, certifications, maintenance, and repairs. In addition to one (1) hard copy of the report, the Contractor shall also provide one (1) electronic copy to the Program POC.\nPreventative Maintenance report will document work performed, referencing the procedures followed, actual tests and/or evaluation results\nA designated staff member will accompany the Contractor as an observer during service work. \nParts and Software:\nAll parts supplied shall be original equipment manufacturer (OEM) and fully compatible with existing equipment. \nAll defective parts replaced become the property of the Contractor, unless otherwise specified by the CO or Program POC. \nSoftware patches and upgrades (if applicable) shall be included for all equipment and shall be compatible with VA s current operating system.\nWindows Operating System that is found to be no longer supported (expired version/build) will be updated by the contractor to current Microsoft supported version/build.\n\nAdditional Requirements:\nAll work shall be completed during normal business hours unless approved by the Program POC \nNormal business hours are between 7am and 4pm ET, Monday through Friday, excluding designated federal holidays. \nIf the contractor wishes to furnish services at a time that is outside of normal hours, at no additional cost to the Government, the contractor shall submit a request to the Program POC and receive written approval prior to the start of any work. \nAny proposed work that falls outside or the scope of the contract shall be provided in writing to the Program POC with a price estimate and shall be authorized by the Contracting Officer with a contract modification prior to the start of any work.\nThere will be no additional charge for time spent waiting at the site during or after the normal hours for coverage for delivery of parts. \nUpon request, the Contractor shall provide factory training certificates/competencies to the Laboratory Service for all technicians assigned to service the equipment to satisfy The Joint Commission (TJC) and the College of American Pathologists (CAP) requirements.","origin":"detail"},"contacts":[{"name":"Jefferson Mann","role":"primary","email":"jefferson.mann@va.gov","phone":"717-202-5456","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"d27abe69280a491c9b9335b0cafd7b5e","name":"36C24426Q0913.docx","kind":"file","mime_type":".docx","size_bytes":38818,"posted_at":"2026-08-19T16:57:38.533Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d27abe69280a491c9b9335b0cafd7b5e/download","mirrored":false},{"resource_id":"f2e0de6e0a7140f2897505b346411fc0","name":"36C24426Q0913.docx","kind":"file","mime_type":".docx","size_bytes":38818,"posted_at":"2026-08-19T16:57:37.958Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f2e0de6e0a7140f2897505b346411fc0/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24427Q0073","latest_notice_id":"130d1e906067454a9520ca90284294e5","title":"J046--IDIQ | Deionization Water System Maintenance and Support","solicitation_number":"36C24427Q0073","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"221310","psc":"J046","set_aside":null,"state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"4BADF0FAA275492A8898366F3CFCB4F9","latest_notice_id":"4badf0faa275492a8898366f3cfcb4f9","title":"Notice of Intent to Sole Source - SmartLab X-ray Diffractometer (XRD) Service Agreement - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"B8164D58E343480FAF72E235E2A2B7BA","latest_notice_id":"b8164d58e343480faf72e235e2a2b7ba","title":"Notice of Intent to Sole Source - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W51AA127QA004","latest_notice_id":"8fe637fd4a2e485d9897807458fad1e1","title":"400 Hz Cycle Converters - Maintenance, Inspections, and Repairs","solicitation_number":"W51AA127QA004","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-14T21:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51AA1","office_name":"W6QK ACC-APG CONT CT TYAD OFC","naics":"811210","psc":"J059","set_aside":"SBA","state":"PA","county":"42089","county_name":"Monroe County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":63,"indexable":false}