{"canonical":"https://sealedbidder.com/opportunities/36c24426q0861","key":"36C24426Q0861","url":"https://sealedbidder.com/opportunities/36c24426q0861","title":"6515--RFI - Portable Dialysis Reverse Osmosis Systems","solicitation_number":"36C24426Q0861","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-11T20:00:00Z","first_posted":"2026-08-04","last_posted":"2026-08-04","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339113","psc":"6515","set_aside":null,"place_state":"DE","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"10003","place_county_name":"New Castle County","place_city":"1077580","place_city_name":"Wilmington","winner":null,"award_amount":null,"publications":[{"notice_id":"297568685c4a4136afa7abcc01e20a3f","title":"6515--RFI - Portable Dialysis Reverse Osmosis Systems","solicitation_number":"36C24426Q0861","notice_type":"r","base_type":"r","posted":"2026-08-04","posted_at":"2026-08-04T18:10:10.313Z","due_at":"2026-08-11T20:00:00Z","due_date":"2026-08-11","cancelled":false,"archived":true,"archive_date":"2026-08-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/297568685c4a4136afa7abcc01e20a3f/view","enriched":true,"history":[{"index":3,"title":"6515--RFI - Portable Dialysis Reverse Osmosis Systems","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T18:10:10.313Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"297568685c4a4136afa7abcc01e20a3f","solicitation_number":"36C24426Q0861"}]}],"latest_notice_id":"297568685c4a4136afa7abcc01e20a3f","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-04","posted_at":"2026-08-04T18:10:10.313Z","created_at":"2026-08-04T18:10:07.970Z","modified_at":"2026-08-26T05:06:42.937Z","response_deadline":{"raw":"2026-08-11T16:00:00-04:00","utc":"2026-08-11T20:00:00Z","date":"2026-08-11","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/297568685c4a4136afa7abcc01e20a3f/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--RFI - Portable Dialysis Reverse Osmosis Systems","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-26","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--RFI - Portable Dialysis Reverse Osmosis Systems","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-04T18:10:10.313Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"297568685c4a4136afa7abcc01e20a3f","solicitation_number":"36C24426Q0861"}],"contacts":[{"name":"Theresa Murray","role":"primary","email":"theresa.murray@va.gov","phone":"(814) 207-0348","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"297568685c4a4136afa7abcc01e20a3f","lineage_id":"297568685c4a4136afa7abcc01e20a3f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T03:06:41.573251610Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"694cd501a9b24aafcfbfa7d2de966e8609d48925223728c398f6eac52641c1cc","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T03:06:41.573251610Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"This is Not a Solicitation Announcement. This is a Request for Information Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Since this is Request for Information announcement, no evaluation letters and/or results will be issued to respondents. No solicitation exists currently. \nThe Department of Veterans Affairs VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified/verified Businesses capable of meeting requirements and salient characteristics below to provide the Wilmington VA Medical Center with Portable Reverse Osmosis Systems. \n\nWILMGTON VA MEDICAL CENTER \nSCOPE OF WORK AND GENERAL SPECIFICATIONS FOR PORTABLE REVERSE OSMOSIS SYSTEMS\n\nBackground\n\nWilmington VAMC requires two brand name or equal to Aqua C 15 Amp, portable reverse osmosis (RO) water purification systems.\n The systems are required to support hemodialysis operations and to ensure a safe, AAMI-compliant water supply for patient care. The current portables require immediate replacement due to frequent, high-level bacterial contamination. Despite rigorous, in-depth disinfection and ongoing maintenance, the units  advanced age and deterioration prevent effective sanitization. \n\nProject Scope\n\nThe Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Aqua C UNO PORTABLE RO 15-amp water purification system which includes equipment installation and training.\n\nThis is a brand name or equal for the following: Aqua C 15 Amp portable reverse osmosis (RO) water purification systems with Softener Portable incl. salt tablet kit, AquaCaddy V2 Backflow Prevention/RPZ, AquaCaddy V2 Bolt on HD Connection kit, AquaCaddy V2 Booster Pump, Aqua Caddy - Dual Carbon Block  \nAAMI Water Profile Kit and Aqua C Uno RO Install with Isopure Cart.\n\nSPECIFIC TASK:\n\n  The contractor shall furnish and deliver the following equipment:\no Two (2) AquaC 15 Amp Portable Reverse Osmosis Systems (Product No. 24-10VA-1)\no Two Softener Portable includes salt tablet kit (Product No. 24-0479-0)\no Two AquaCaddy V2 Backflow Prevention/RPZ (Product No. \no  24-ACBF-0)\no Two AquaCaddy V2 Bolt on HD Connection. Kit (Option) (Product No. 24-ACCK-0)\no Two AquaCaddy V2 Booster Pump (Product No.24-ACBP-0)\no Two Aqua Caddy - Dual Carbon Block (Product No. 24-AC02-0)\no Two AAMI Water Profile Kit (Product No.24-AAMI-0)\no Two Aqua C Uno RO Install with Isopure Cart (Product No.111147)\n\n  The contractor shall provide complete installation of all two (2) AquaC RO units, including accessories, plumbing connections, and system commissioning.\n\n  The contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs in accordance with the following parameters:\n\no Service: AquaC System Training (Product No. 111122)\no One (1) follow-up training session is included within the contract price.\no Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply.\no Portable RO must be compatible with Fresenius 2008T BlueStar dialysis machines.\n\nRequired salient characteristics the unit must meet the following: \nSystem Type\nPortable, single-patient reverse osmosis (RO) water purification system\nHeight\n50cm unit only, excluding cart\nWidth\n52cm\nDepth\n20cm\nWeight (Empty)\nApproximately 35 kg (77.2 lb)\nWeight (Full)\nApproximately 37.5 kg (82.7 lb)\nPortability\nMust be cart-mounted and portable within the clinical environment; no permanent plumbing required\nWater Quality Standard\nMust meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants\nPermeate Output\nMinimum 85 L/h (Â±10%) at 15Â°C (59Â°F) water inlet temperature\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nElectrical Supply\n120 V AC, 60 Hz, 15.5 Amp\nNominal Power Variants\n120 V   1000 VA or 120 V   1700 VA (per voltage variant) \nOperating Mode\nContinuous operation (Standby); SUPPLY mode used periodically during treatment\nElectrical Safety Classification\nClassified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012\nGrounding Requirement\nMust be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted\nFuse Protection\nInternal fuses for voltage component protection; replaceable only by trained/certified personnel\nEMC Compliance\nCompliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices\nInterface / Connectivity\nFresenius hemodialysis device interface port; compatible with Fresenius 2008T BlueStar dialysis machines\nThermal Disinfection   Module\nModule heat disinfection up to 82Â°C (179.6Â°F)\nThermal Disinfection   Ring\nRing heat disinfection up to 90Â°C (194Â°F)\nMembrane Service Life\nMinimum expected life of 120 heat disinfection cycles\nChemical Disinfection\nCompatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal)\nDecalcification\nCompatible with approximately 20% citric acid solution; automated decalcification program required\nRinse Interval\nAutomated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time\nAutoSTART / AutoSTOP\nSystem shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine\nDisinfection Validation\nSystem must provide auditable disinfection reporting and daily operational data acquisition logs\nBiocompatibility Standard\nAll components in contact with permeate must be biocompatible per DIN EN ISO 10993-1\nTubing / Piping Material\nFEP, silicone, or stainless steel; food-grade with chemical resistance\nSensors\nTitanium (Ti), Aluminum Oxide (Al O ), PBT\nModule Tube\nV4A stainless steel\nMembrane Material\nPSU/PA (polysulfone/polyamide)\nHydraulic Blocks / Valves\niPP, PVDF, Noryl GTX\nSeals\nEPDM (ethylene propylene diene monomer)\nSampling Ports\nIntegrated permeate sampling ports for microbiological and chemical analysis\nPermeate Connection\nPermeate nipple; optional permeate coupling; compatible with Fresenius hemodialysis machine water inlet\nFeed / Concentrate Flow\nFeed flow: 0.0 20 L/min (Â±10%); Concentrate flow: 0.0 20 L/min (Â±10%)\nPermeate Consumption\n0 6 L/min (Â±10%) during normal supply operation\nDrain Connection\nSystem drain must connect to available outlet; no recontamination of permeate circuit permitted\nWater Supply Hose\nMust connect to potable water supply meeting pre-treatment feed water requirements\nInstallation Type\nPortable; no permanent wall or floor mounting required; \nStacking / Adjacency\nSystem must NOT be stacked with other electrical devices; minimum separation distances from radiation sources required per IFU\nOperational Qualification\nVendor must perform Installation and Operational Qualification (IQ/OQ) at time of installation\nDisplay\nIntegrated digital display with operating mode status bar; multilingual support\nPermeate Conductivity Monitoring\nContinuous real-time permeate conductivity measurement and display; alarm on out-of-range condition\nFeed Water Conductivity\nContinuous real-time feed water conductivity measurement and display\nTemperature Monitoring\nPermeate and concentrate temperature display; heater temperature 1.0 135Â°C (Â±1Â°C); concentrate temperature 1.0 135Â°C (Â±1Â°C)\nRejection Rate Display\nReal-time rejection rate display: 0.0 99% (Â±1%)\nEffective Yield Display\nEffective yield display: 0.0 70% (Â±5%)\nAlarm System\nAudible and visual alarms for: no water supply, fault drain, conductivity fault, sensor error, and other abnormal conditions; alarm must halt dialysis supply automatically\nOperational Data Logging\nSystem must support manual and automated daily operational data acquisition and reporting per AAMI requirements\nVisual Status Indicator\nGreen visual indicator must illuminate to confirm system is ready for treatment\n\nTRAINING:\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs.\n\nDELIVERY/PLACE OF PERFORMANCE:  \n\nDelivery shall be within 90 days after receipt of contract. Deliver equipment to:\n\nWilmington VA Medical Center (Attn: Shayonna Smith) \nDialysis Department \n1601 Kirkwood Hwy\nWilmington, DE 19805-2917\n\nPrior to delivery, Contractor shall verify shipment with the Point of Contact (POC). Once confirmed, tracking information, quantity and estimated arrival shall be provided.\nThe Contractor must comply and provide all necessary verification and information to the VAMC. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. \nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industry Classification code (NAICS) 339113, The Small Business Size Standard for this NAICS code is 800 employees. \n\nPlease answer the following questions:\n\n(1) Please indicate the size status and representations of your businessÂ in accordance with the NAICS code 339113, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB),Â Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\n(2)Â Is the required equipment available on a Federal Supply Schedule or Government WideÂ Acquisition Contract?Â  If so, please include the schedule number.Â \n\n(3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?Â \n\nIf not,Â provide additional information shown below.Â  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.Â \n\n  DoesÂ your companyÂ exceed 500 employeesÂ \n\n  Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;Â Â Â \n\n  Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;Â Â \n\n  Provide the items of a small business \n\n(4) If your company is aÂ large business, do you have anyÂ authorized small businessÂ distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).Â \n\n(5) If your company isÂ a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?Â \n\n(6) Is the item you are supplying made or manufactured in America? This is to ensure compliance with FAR 52.225-1 Buy American-Supplies.\n\n(7) If you intend toÂ subcontractÂ any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.Â \n(8) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.Â \n\n(9) Please submit your capabilitiesÂ in regard toÂ the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?Â \n\n(10) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.Â \n\n(11) Please provide your UEI number.Â \n\n*** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all  equal to items\" meet all the salient characteristics.Â \n\nThisÂ RFIÂ will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted.\n\nResponses must be receivedÂ via email to Contract Specialist Theresa Murray at  Theresa.Murray@va.gov no later than 4:00 PM Eastern Standard Time on Tuesday, August 11, 2026. \n\nThis notice will help the VA in determining available potential sources only.Â Â Do not contact VA Medical Center staffÂ regardingÂ this requirement, as they are not authorized to discussÂ this matterÂ related to this procurement action.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal,Â therefore will not be considered for a contract award.Â Â \nÂ \nIf a solicitation is issued, information will be posted on SAM.gov web site for all qualified interested partiesÂ at a later dateÂ and interested parties must respond to the solicitation to be considered for award.Â Â This notice does not commit the government to contract for anyÂ supplies orÂ services.Â Â The government will not pay for any information or administrative cost incurred in response to this Request for Information.Â Â Information will only be accepted in writing via email.\n\nDISCLAIMER:\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.Â Â Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.Â Â Responders are solely responsible for all expenses associated with responding to this RFI.Â","text":"This is Not a Solicitation Announcement. This is a Request for Information Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Since this is Request for Information announcement, no evaluation letters and/or results will be issued to respondents. No solicitation exists currently.\nThe Department of Veterans Affairs VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified/verified Businesses capable of meeting requirements and salient characteristics below to provide the Wilmington VA Medical Center with Portable Reverse Osmosis Systems.\n\nWILMGTON VA MEDICAL CENTER\nSCOPE OF WORK AND GENERAL SPECIFICATIONS FOR PORTABLE REVERSE OSMOSIS SYSTEMS\n\nBackground\n\nWilmington VAMC requires two brand name or equal to Aqua C 15 Amp, portable reverse osmosis (RO) water purification systems.\nThe systems are required to support hemodialysis operations and to ensure a safe, AAMI-compliant water supply for patient care. The current portables require immediate replacement due to frequent, high-level bacterial contamination. Despite rigorous, in-depth disinfection and ongoing maintenance, the units advanced age and deterioration prevent effective sanitization.\n\nProject Scope\n\nThe Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Aqua C UNO PORTABLE RO 15-amp water purification system which includes equipment installation and training.\n\nThis is a brand name or equal for the following: Aqua C 15 Amp portable reverse osmosis (RO) water purification systems with Softener Portable incl. salt tablet kit, AquaCaddy V2 Backflow Prevention/RPZ, AquaCaddy V2 Bolt on HD Connection kit, AquaCaddy V2 Booster Pump, Aqua Caddy - Dual Carbon Block\nAAMI Water Profile Kit and Aqua C Uno RO Install with Isopure Cart.\n\nSPECIFIC TASK:\n\nThe contractor shall furnish and deliver the following equipment:\no Two (2) AquaC 15 Amp Portable Reverse Osmosis Systems (Product No. 24-10VA-1)\no Two Softener Portable includes salt tablet kit (Product No. 24-0479-0)\no Two AquaCaddy V2 Backflow Prevention/RPZ (Product No.\no 24-ACBF-0)\no Two AquaCaddy V2 Bolt on HD Connection. Kit (Option) (Product No. 24-ACCK-0)\no Two AquaCaddy V2 Booster Pump (Product No.24-ACBP-0)\no Two Aqua Caddy - Dual Carbon Block (Product No. 24-AC02-0)\no Two AAMI Water Profile Kit (Product No.24-AAMI-0)\no Two Aqua C Uno RO Install with Isopure Cart (Product No.111147)\n\nThe contractor shall provide complete installation of all two (2) AquaC RO units, including accessories, plumbing connections, and system commissioning.\n\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs in accordance with the following parameters:\n\no Service: AquaC System Training (Product No. 111122)\no One (1) follow-up training session is included within the contract price.\no Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply.\no Portable RO must be compatible with Fresenius 2008T BlueStar dialysis machines.\n\nRequired salient characteristics the unit must meet the following:\nSystem Type\nPortable, single-patient reverse osmosis (RO) water purification system\nHeight\n50cm unit only, excluding cart\nWidth\n52cm\nDepth\n20cm\nWeight (Empty)\nApproximately 35 kg (77.2 lb)\nWeight (Full)\nApproximately 37.5 kg (82.7 lb)\nPortability\nMust be cart-mounted and portable within the clinical environment; no permanent plumbing required\nWater Quality Standard\nMust meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants\nPermeate Output\nMinimum 85 L/h (Â±10%) at 15Â°C (59Â°F) water inlet temperature\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nElectrical Supply\n120 V AC, 60 Hz, 15.5 Amp\nNominal Power Variants\n120 V 1000 VA or 120 V 1700 VA (per voltage variant)\nOperating Mode\nContinuous operation (Standby); SUPPLY mode used periodically during treatment\nElectrical Safety Classification\nClassified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012\nGrounding Requirement\nMust be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted\nFuse Protection\nInternal fuses for voltage component protection; replaceable only by trained/certified personnel\nEMC Compliance\nCompliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices\nInterface / Connectivity\nFresenius hemodialysis device interface port; compatible with Fresenius 2008T BlueStar dialysis machines\nThermal Disinfection Module\nModule heat disinfection up to 82Â°C (179.6Â°F)\nThermal Disinfection Ring\nRing heat disinfection up to 90Â°C (194Â°F)\nMembrane Service Life\nMinimum expected life of 120 heat disinfection cycles\nChemical Disinfection\nCompatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal)\nDecalcification\nCompatible with approximately 20% citric acid solution; automated decalcification program required\nRinse Interval\nAutomated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time\nAutoSTART / AutoSTOP\nSystem shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine\nDisinfection Validation\nSystem must provide auditable disinfection reporting and daily operational data acquisition logs\nBiocompatibility Standard\nAll components in contact with permeate must be biocompatible per DIN EN ISO 10993-1\nTubing / Piping Material\nFEP, silicone, or stainless steel; food-grade with chemical resistance\nSensors\nTitanium (Ti), Aluminum Oxide (Al O ), PBT\nModule Tube\nV4A stainless steel\nMembrane Material\nPSU/PA (polysulfone/polyamide)\nHydraulic Blocks / Valves\niPP, PVDF, Noryl GTX\nSeals\nEPDM (ethylene propylene diene monomer)\nSampling Ports\nIntegrated permeate sampling ports for microbiological and chemical analysis\nPermeate Connection\nPermeate nipple; optional permeate coupling; compatible with Fresenius hemodialysis machine water inlet\nFeed / Concentrate Flow\nFeed flow: 0.0 20 L/min (Â±10%); Concentrate flow: 0.0 20 L/min (Â±10%)\nPermeate Consumption\n0 6 L/min (Â±10%) during normal supply operation\nDrain Connection\nSystem drain must connect to available outlet; no recontamination of permeate circuit permitted\nWater Supply Hose\nMust connect to potable water supply meeting pre-treatment feed water requirements\nInstallation Type\nPortable; no permanent wall or floor mounting required;\nStacking / Adjacency\nSystem must NOT be stacked with other electrical devices; minimum separation distances from radiation sources required per IFU\nOperational Qualification\nVendor must perform Installation and Operational Qualification (IQ/OQ) at time of installation\nDisplay\nIntegrated digital display with operating mode status bar; multilingual support\nPermeate Conductivity Monitoring\nContinuous real-time permeate conductivity measurement and display; alarm on out-of-range condition\nFeed Water Conductivity\nContinuous real-time feed water conductivity measurement and display\nTemperature Monitoring\nPermeate and concentrate temperature display; heater temperature 1.0 135Â°C (Â±1Â°C); concentrate temperature 1.0 135Â°C (Â±1Â°C)\nRejection Rate Display\nReal-time rejection rate display: 0.0 99% (Â±1%)\nEffective Yield Display\nEffective yield display: 0.0 70% (Â±5%)\nAlarm System\nAudible and visual alarms for: no water supply, fault drain, conductivity fault, sensor error, and other abnormal conditions; alarm must halt dialysis supply automatically\nOperational Data Logging\nSystem must support manual and automated daily operational data acquisition and reporting per AAMI requirements\nVisual Status Indicator\nGreen visual indicator must illuminate to confirm system is ready for treatment\n\nTRAINING:\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs.\n\nDELIVERY/PLACE OF PERFORMANCE:\n\nDelivery shall be within 90 days after receipt of contract. Deliver equipment to:\n\nWilmington VA Medical Center (Attn: Shayonna Smith)\nDialysis Department\n1601 Kirkwood Hwy\nWilmington, DE 19805-2917\n\nPrior to delivery, Contractor shall verify shipment with the Point of Contact (POC). Once confirmed, tracking information, quantity and estimated arrival shall be provided.\nThe Contractor must comply and provide all necessary verification and information to the VAMC. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industry Classification code (NAICS) 339113, The Small Business Size Standard for this NAICS code is 800 employees.\n\nPlease answer the following questions:\n\n(1) Please indicate the size status and representations of your businessÂ in accordance with the NAICS code 339113, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB),Â Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\n(2)Â Is the required equipment available on a Federal Supply Schedule or Government WideÂ Acquisition Contract?Â If so, please include the schedule number.Â\n\n(3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?Â\n\nIf not,Â provide additional information shown below.Â This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.Â\n\nDoesÂ your companyÂ exceed 500 employeesÂ\n\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;Â Â Â\n\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;Â Â\n\nProvide the items of a small business\n\n(4) If your company is aÂ large business, do you have anyÂ authorized small businessÂ distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).Â\n\n(5) If your company isÂ a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?Â\n\n(6) Is the item you are supplying made or manufactured in America? This is to ensure compliance with FAR 52.225-1 Buy American-Supplies.\n\n(7) If you intend toÂ subcontractÂ any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.Â\n(8) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.Â\n\n(9) Please submit your capabilitiesÂ in regard toÂ the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?Â\n\n(10) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.Â\n\n(11) Please provide your UEI number.Â\n\n*** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all equal to items\" meet all the salient characteristics.Â\n\nThisÂ RFIÂ will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted.\n\nResponses must be receivedÂ via email to Contract Specialist Theresa Murray at Theresa.Murray@va.gov no later than 4:00 PM Eastern Standard Time on Tuesday, August 11, 2026.\n\nThis notice will help the VA in determining available potential sources only.Â Â Do not contact VA Medical Center staffÂ regardingÂ this requirement, as they are not authorized to discussÂ this matterÂ related to this procurement action.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal,Â therefore will not be considered for a contract award.Â Â\nÂ\nIf a solicitation is issued, information will be posted on SAM.gov web site for all qualified interested partiesÂ at a later dateÂ and interested parties must respond to the solicitation to be considered for award.Â Â This notice does not commit the government to contract for anyÂ supplies orÂ services.Â Â The government will not pay for any information or administrative cost incurred in response to this Request for Information.Â Â Information will only be accepted in writing via email.\n\nDISCLAIMER:\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.Â Â Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.Â Â Responders are solely responsible for all expenses associated with responding to this RFI.Â","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24426Q0861","place_of_performance":{"zip":"19805-2917","city":{"code":"77580","name":"Wilmington"},"state":{"code":"DE","name":"Delaware"},"street":"Wilmington VA Medical Center Dialysis Department","country":{"code":"USA","name":"UNITED STATES"},"street2":"1601 Kirkwood Hwy"},"product_service_code":"6515"}],"due_at":"2026-08-11T20:00:00Z","due_date":"2026-08-11","closes_at":"2026-08-11T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-26T03:17:36.221267Z","principal_notice_id":"297568685c4a4136afa7abcc01e20a3f","description":{"text":"This is Not a Solicitation Announcement. This is a Request for Information Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Since this is Request for Information announcement, no evaluation letters and/or results will be issued to respondents. No solicitation exists currently.\nThe Department of Veterans Affairs VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified/verified Businesses capable of meeting requirements and salient characteristics below to provide the Wilmington VA Medical Center with Portable Reverse Osmosis Systems.\n\nWILMGTON VA MEDICAL CENTER\nSCOPE OF WORK AND GENERAL SPECIFICATIONS FOR PORTABLE REVERSE OSMOSIS SYSTEMS\n\nBackground\n\nWilmington VAMC requires two brand name or equal to Aqua C 15 Amp, portable reverse osmosis (RO) water purification systems.\nThe systems are required to support hemodialysis operations and to ensure a safe, AAMI-compliant water supply for patient care. The current portables require immediate replacement due to frequent, high-level bacterial contamination. Despite rigorous, in-depth disinfection and ongoing maintenance, the units advanced age and deterioration prevent effective sanitization.\n\nProject Scope\n\nThe Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Aqua C UNO PORTABLE RO 15-amp water purification system which includes equipment installation and training.\n\nThis is a brand name or equal for the following: Aqua C 15 Amp portable reverse osmosis (RO) water purification systems with Softener Portable incl. salt tablet kit, AquaCaddy V2 Backflow Prevention/RPZ, AquaCaddy V2 Bolt on HD Connection kit, AquaCaddy V2 Booster Pump, Aqua Caddy - Dual Carbon Block\nAAMI Water Profile Kit and Aqua C Uno RO Install with Isopure Cart.\n\nSPECIFIC TASK:\n\nThe contractor shall furnish and deliver the following equipment:\no Two (2) AquaC 15 Amp Portable Reverse Osmosis Systems (Product No. 24-10VA-1)\no Two Softener Portable includes salt tablet kit (Product No. 24-0479-0)\no Two AquaCaddy V2 Backflow Prevention/RPZ (Product No.\no 24-ACBF-0)\no Two AquaCaddy V2 Bolt on HD Connection. Kit (Option) (Product No. 24-ACCK-0)\no Two AquaCaddy V2 Booster Pump (Product No.24-ACBP-0)\no Two Aqua Caddy - Dual Carbon Block (Product No. 24-AC02-0)\no Two AAMI Water Profile Kit (Product No.24-AAMI-0)\no Two Aqua C Uno RO Install with Isopure Cart (Product No.111147)\n\nThe contractor shall provide complete installation of all two (2) AquaC RO units, including accessories, plumbing connections, and system commissioning.\n\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs in accordance with the following parameters:\n\no Service: AquaC System Training (Product No. 111122)\no One (1) follow-up training session is included within the contract price.\no Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply.\no Portable RO must be compatible with Fresenius 2008T BlueStar dialysis machines.\n\nRequired salient characteristics the unit must meet the following:\nSystem Type\nPortable, single-patient reverse osmosis (RO) water purification system\nHeight\n50cm unit only, excluding cart\nWidth\n52cm\nDepth\n20cm\nWeight (Empty)\nApproximately 35 kg (77.2 lb)\nWeight (Full)\nApproximately 37.5 kg (82.7 lb)\nPortability\nMust be cart-mounted and portable within the clinical environment; no permanent plumbing required\nWater Quality Standard\nMust meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants\nPermeate Output\nMinimum 85 L/h (Â±10%) at 15Â°C (59Â°F) water inlet temperature\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness 1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nElectrical Supply\n120 V AC, 60 Hz, 15.5 Amp\nNominal Power Variants\n120 V 1000 VA or 120 V 1700 VA (per voltage variant)\nOperating Mode\nContinuous operation (Standby); SUPPLY mode used periodically during treatment\nElectrical Safety Classification\nClassified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012\nGrounding Requirement\nMust be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted\nFuse Protection\nInternal fuses for voltage component protection; replaceable only by trained/certified personnel\nEMC Compliance\nCompliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices\nInterface / Connectivity\nFresenius hemodialysis device interface port; compatible with Fresenius 2008T BlueStar dialysis machines\nThermal Disinfection Module\nModule heat disinfection up to 82Â°C (179.6Â°F)\nThermal Disinfection Ring\nRing heat disinfection up to 90Â°C (194Â°F)\nMembrane Service Life\nMinimum expected life of 120 heat disinfection cycles\nChemical Disinfection\nCompatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal)\nDecalcification\nCompatible with approximately 20% citric acid solution; automated decalcification program required\nRinse Interval\nAutomated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time\nAutoSTART / AutoSTOP\nSystem shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine\nDisinfection Validation\nSystem must provide auditable disinfection reporting and daily operational data acquisition logs\nBiocompatibility Standard\nAll components in contact with permeate must be biocompatible per DIN EN ISO 10993-1\nTubing / Piping Material\nFEP, silicone, or stainless steel; food-grade with chemical resistance\nSensors\nTitanium (Ti), Aluminum Oxide (Al O ), PBT\nModule Tube\nV4A stainless steel\nMembrane Material\nPSU/PA (polysulfone/polyamide)\nHydraulic Blocks / Valves\niPP, PVDF, Noryl GTX\nSeals\nEPDM (ethylene propylene diene monomer)\nSampling Ports\nIntegrated permeate sampling ports for microbiological and chemical analysis\nPermeate Connection\nPermeate nipple; optional permeate coupling; compatible with Fresenius hemodialysis machine water inlet\nFeed / Concentrate Flow\nFeed flow: 0.0 20 L/min (Â±10%); Concentrate flow: 0.0 20 L/min (Â±10%)\nPermeate Consumption\n0 6 L/min (Â±10%) during normal supply operation\nDrain Connection\nSystem drain must connect to available outlet; no recontamination of permeate circuit permitted\nWater Supply Hose\nMust connect to potable water supply meeting pre-treatment feed water requirements\nInstallation Type\nPortable; no permanent wall or floor mounting required;\nStacking / Adjacency\nSystem must NOT be stacked with other electrical devices; minimum separation distances from radiation sources required per IFU\nOperational Qualification\nVendor must perform Installation and Operational Qualification (IQ/OQ) at time of installation\nDisplay\nIntegrated digital display with operating mode status bar; multilingual support\nPermeate Conductivity Monitoring\nContinuous real-time permeate conductivity measurement and display; alarm on out-of-range condition\nFeed Water Conductivity\nContinuous real-time feed water conductivity measurement and display\nTemperature Monitoring\nPermeate and concentrate temperature display; heater temperature 1.0 135Â°C (Â±1Â°C); concentrate temperature 1.0 135Â°C (Â±1Â°C)\nRejection Rate Display\nReal-time rejection rate display: 0.0 99% (Â±1%)\nEffective Yield Display\nEffective yield display: 0.0 70% (Â±5%)\nAlarm System\nAudible and visual alarms for: no water supply, fault drain, conductivity fault, sensor error, and other abnormal conditions; alarm must halt dialysis supply automatically\nOperational Data Logging\nSystem must support manual and automated daily operational data acquisition and reporting per AAMI requirements\nVisual Status Indicator\nGreen visual indicator must illuminate to confirm system is ready for treatment\n\nTRAINING:\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs.\n\nDELIVERY/PLACE OF PERFORMANCE:\n\nDelivery shall be within 90 days after receipt of contract. Deliver equipment to:\n\nWilmington VA Medical Center (Attn: Shayonna Smith)\nDialysis Department\n1601 Kirkwood Hwy\nWilmington, DE 19805-2917\n\nPrior to delivery, Contractor shall verify shipment with the Point of Contact (POC). Once confirmed, tracking information, quantity and estimated arrival shall be provided.\nThe Contractor must comply and provide all necessary verification and information to the VAMC. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industry Classification code (NAICS) 339113, The Small Business Size Standard for this NAICS code is 800 employees.\n\nPlease answer the following questions:\n\n(1) Please indicate the size status and representations of your businessÂ in accordance with the NAICS code 339113, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB),Â Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\n(2)Â Is the required equipment available on a Federal Supply Schedule or Government WideÂ Acquisition Contract?Â If so, please include the schedule number.Â\n\n(3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?Â\n\nIf not,Â provide additional information shown below.Â This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.Â\n\nDoesÂ your companyÂ exceed 500 employeesÂ\n\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;Â Â Â\n\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;Â Â\n\nProvide the items of a small business\n\n(4) If your company is aÂ large business, do you have anyÂ authorized small businessÂ distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).Â\n\n(5) If your company isÂ a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?Â\n\n(6) Is the item you are supplying made or manufactured in America? This is to ensure compliance with FAR 52.225-1 Buy American-Supplies.\n\n(7) If you intend toÂ subcontractÂ any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.Â\n(8) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.Â\n\n(9) Please submit your capabilitiesÂ in regard toÂ the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?Â\n\n(10) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.Â\n\n(11) Please provide your UEI number.Â\n\n*** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all equal to items\" meet all the salient characteristics.Â\n\nThisÂ RFIÂ will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted.\n\nResponses must be receivedÂ via email to Contract Specialist Theresa Murray at Theresa.Murray@va.gov no later than 4:00 PM Eastern Standard Time on Tuesday, August 11, 2026.\n\nThis notice will help the VA in determining available potential sources only.Â Â Do not contact VA Medical Center staffÂ regardingÂ this requirement, as they are not authorized to discussÂ this matterÂ related to this procurement action.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal,Â therefore will not be considered for a contract award.Â Â\nÂ\nIf a solicitation is issued, information will be posted on SAM.gov web site for all qualified interested partiesÂ at a later dateÂ and interested parties must respond to the solicitation to be considered for award.Â Â This notice does not commit the government to contract for anyÂ supplies orÂ services.Â Â The government will not pay for any information or administrative cost incurred in response to this Request for Information.Â Â Information will only be accepted in writing via email.\n\nDISCLAIMER:\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.Â Â Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.Â Â Responders are solely responsible for all expenses associated with responding to this RFI.Â","html":"This is Not a Solicitation Announcement. This is a Request for Information Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Since this is Request for Information announcement, no evaluation letters and/or results will be issued to respondents. No solicitation exists currently. \nThe Department of Veterans Affairs VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified/verified Businesses capable of meeting requirements and salient characteristics below to provide the Wilmington VA Medical Center with Portable Reverse Osmosis Systems. \n\nWILMGTON VA MEDICAL CENTER \nSCOPE OF WORK AND GENERAL SPECIFICATIONS FOR PORTABLE REVERSE OSMOSIS SYSTEMS\n\nBackground\n\nWilmington VAMC requires two brand name or equal to Aqua C 15 Amp, portable reverse osmosis (RO) water purification systems.\n The systems are required to support hemodialysis operations and to ensure a safe, AAMI-compliant water supply for patient care. The current portables require immediate replacement due to frequent, high-level bacterial contamination. Despite rigorous, in-depth disinfection and ongoing maintenance, the units  advanced age and deterioration prevent effective sanitization. \n\nProject Scope\n\nThe Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Aqua C UNO PORTABLE RO 15-amp water purification system which includes equipment installation and training.\n\nThis is a brand name or equal for the following: Aqua C 15 Amp portable reverse osmosis (RO) water purification systems with Softener Portable incl. salt tablet kit, AquaCaddy V2 Backflow Prevention/RPZ, AquaCaddy V2 Bolt on HD Connection kit, AquaCaddy V2 Booster Pump, Aqua Caddy - Dual Carbon Block  \nAAMI Water Profile Kit and Aqua C Uno RO Install with Isopure Cart.\n\nSPECIFIC TASK:\n\n  The contractor shall furnish and deliver the following equipment:\no Two (2) AquaC 15 Amp Portable Reverse Osmosis Systems (Product No. 24-10VA-1)\no Two Softener Portable includes salt tablet kit (Product No. 24-0479-0)\no Two AquaCaddy V2 Backflow Prevention/RPZ (Product No. \no  24-ACBF-0)\no Two AquaCaddy V2 Bolt on HD Connection. Kit (Option) (Product No. 24-ACCK-0)\no Two AquaCaddy V2 Booster Pump (Product No.24-ACBP-0)\no Two Aqua Caddy - Dual Carbon Block (Product No. 24-AC02-0)\no Two AAMI Water Profile Kit (Product No.24-AAMI-0)\no Two Aqua C Uno RO Install with Isopure Cart (Product No.111147)\n\n  The contractor shall provide complete installation of all two (2) AquaC RO units, including accessories, plumbing connections, and system commissioning.\n\n  The contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs in accordance with the following parameters:\n\no Service: AquaC System Training (Product No. 111122)\no One (1) follow-up training session is included within the contract price.\no Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply.\no Portable RO must be compatible with Fresenius 2008T BlueStar dialysis machines.\n\nRequired salient characteristics the unit must meet the following: \nSystem Type\nPortable, single-patient reverse osmosis (RO) water purification system\nHeight\n50cm unit only, excluding cart\nWidth\n52cm\nDepth\n20cm\nWeight (Empty)\nApproximately 35 kg (77.2 lb)\nWeight (Full)\nApproximately 37.5 kg (82.7 lb)\nPortability\nMust be cart-mounted and portable within the clinical environment; no permanent plumbing required\nWater Quality Standard\nMust meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants\nPermeate Output\nMinimum 85 L/h (Â±10%) at 15Â°C (59Â°F) water inlet temperature\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nBacterial / Endotoxin Rejection\nGreater than 99% rejection rate for bacteria and endotoxins\nDissolved Salt Rejection\nGreater than 96% average rejection rate for dissolved salts\nMembrane Type\nSpirally-wound RO membrane\nYield (Low Hardness)\nUp to 70% at feed water hardness <1 Â°dH (<17.8 ppm CaCO3)\nYield (Higher Hardness)\nUp to 60% at feed water hardness >1 Â°dH (>17.8 ppm CaCO3)\nConcentrate Pressure (Max)\nMaximum 290.1 psi\nNoise Level (SUPPLY mode)\n44 46 dB(A) measured at 1 meter distance\nPermeate Output (Disinfection)\n12 L/h (Â±10%) during ring heat disinfection cycle\nElectrical Supply\n120 V AC, 60 Hz, 15.5 Amp\nNominal Power Variants\n120 V   1000 VA or 120 V   1700 VA (per voltage variant) \nOperating Mode\nContinuous operation (Standby); SUPPLY mode used periodically during treatment\nElectrical Safety Classification\nClassified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012\nGrounding Requirement\nMust be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted\nFuse Protection\nInternal fuses for voltage component protection; replaceable only by trained/certified personnel\nEMC Compliance\nCompliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices\nInterface / Connectivity\nFresenius hemodialysis device interface port; compatible with Fresenius 2008T BlueStar dialysis machines\nThermal Disinfection   Module\nModule heat disinfection up to 82Â°C (179.6Â°F)\nThermal Disinfection   Ring\nRing heat disinfection up to 90Â°C (194Â°F)\nMembrane Service Life\nMinimum expected life of 120 heat disinfection cycles\nChemical Disinfection\nCompatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal)\nDecalcification\nCompatible with approximately 20% citric acid solution; automated decalcification program required\nRinse Interval\nAutomated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time\nAutoSTART / AutoSTOP\nSystem shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine\nDisinfection Validation\nSystem must provide auditable disinfection reporting and daily operational data acquisition logs\nBiocompatibility Standard\nAll components in contact with permeate must be biocompatible per DIN EN ISO 10993-1\nTubing / Piping Material\nFEP, silicone, or stainless steel; food-grade with chemical resistance\nSensors\nTitanium (Ti), Aluminum Oxide (Al O ), PBT\nModule Tube\nV4A stainless steel\nMembrane Material\nPSU/PA (polysulfone/polyamide)\nHydraulic Blocks / Valves\niPP, PVDF, Noryl GTX\nSeals\nEPDM (ethylene propylene diene monomer)\nSampling Ports\nIntegrated permeate sampling ports for microbiological and chemical analysis\nPermeate Connection\nPermeate nipple; optional permeate coupling; compatible with Fresenius hemodialysis machine water inlet\nFeed / Concentrate Flow\nFeed flow: 0.0 20 L/min (Â±10%); Concentrate flow: 0.0 20 L/min (Â±10%)\nPermeate Consumption\n0 6 L/min (Â±10%) during normal supply operation\nDrain Connection\nSystem drain must connect to available outlet; no recontamination of permeate circuit permitted\nWater Supply Hose\nMust connect to potable water supply meeting pre-treatment feed water requirements\nInstallation Type\nPortable; no permanent wall or floor mounting required; \nStacking / Adjacency\nSystem must NOT be stacked with other electrical devices; minimum separation distances from radiation sources required per IFU\nOperational Qualification\nVendor must perform Installation and Operational Qualification (IQ/OQ) at time of installation\nDisplay\nIntegrated digital display with operating mode status bar; multilingual support\nPermeate Conductivity Monitoring\nContinuous real-time permeate conductivity measurement and display; alarm on out-of-range condition\nFeed Water Conductivity\nContinuous real-time feed water conductivity measurement and display\nTemperature Monitoring\nPermeate and concentrate temperature display; heater temperature 1.0 135Â°C (Â±1Â°C); concentrate temperature 1.0 135Â°C (Â±1Â°C)\nRejection Rate Display\nReal-time rejection rate display: 0.0 99% (Â±1%)\nEffective Yield Display\nEffective yield display: 0.0 70% (Â±5%)\nAlarm System\nAudible and visual alarms for: no water supply, fault drain, conductivity fault, sensor error, and other abnormal conditions; alarm must halt dialysis supply automatically\nOperational Data Logging\nSystem must support manual and automated daily operational data acquisition and reporting per AAMI requirements\nVisual Status Indicator\nGreen visual indicator must illuminate to confirm system is ready for treatment\n\nTRAINING:\nThe contractor shall provide on-site training for Medical Center clinical dialysis staff and Bio-Med techs.\n\nDELIVERY/PLACE OF PERFORMANCE:  \n\nDelivery shall be within 90 days after receipt of contract. Deliver equipment to:\n\nWilmington VA Medical Center (Attn: Shayonna Smith) \nDialysis Department \n1601 Kirkwood Hwy\nWilmington, DE 19805-2917\n\nPrior to delivery, Contractor shall verify shipment with the Point of Contact (POC). Once confirmed, tracking information, quantity and estimated arrival shall be provided.\nThe Contractor must comply and provide all necessary verification and information to the VAMC. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government. \nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industry Classification code (NAICS) 339113, The Small Business Size Standard for this NAICS code is 800 employees. \n\nPlease answer the following questions:\n\n(1) Please indicate the size status and representations of your businessÂ in accordance with the NAICS code 339113, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB),Â Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)\n\n(2)Â Is the required equipment available on a Federal Supply Schedule or Government WideÂ Acquisition Contract?Â  If so, please include the schedule number.Â \n\n(3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?Â \n\nIf not,Â provide additional information shown below.Â  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.Â \n\n  DoesÂ your companyÂ exceed 500 employeesÂ \n\n  Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;Â Â Â \n\n  Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;Â Â \n\n  Provide the items of a small business \n\n(4) If your company is aÂ large business, do you have anyÂ authorized small businessÂ distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).Â \n\n(5) If your company isÂ a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?Â \n\n(6) Is the item you are supplying made or manufactured in America? This is to ensure compliance with FAR 52.225-1 Buy American-Supplies.\n\n(7) If you intend toÂ subcontractÂ any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.Â \n(8) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.Â \n\n(9) Please submit your capabilitiesÂ in regard toÂ the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?Â \n\n(10) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.Â \n\n(11) Please provide your UEI number.Â \n\n*** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all  equal to items\" meet all the salient characteristics.Â \n\nThisÂ RFIÂ will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted.\n\nResponses must be receivedÂ via email to Contract Specialist Theresa Murray at  Theresa.Murray@va.gov no later than 4:00 PM Eastern Standard Time on Tuesday, August 11, 2026. \n\nThis notice will help the VA in determining available potential sources only.Â Â Do not contact VA Medical Center staffÂ regardingÂ this requirement, as they are not authorized to discussÂ this matterÂ related to this procurement action.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal,Â therefore will not be considered for a contract award.Â Â \nÂ \nIf a solicitation is issued, information will be posted on SAM.gov web site for all qualified interested partiesÂ at a later dateÂ and interested parties must respond to the solicitation to be considered for award.Â Â This notice does not commit the government to contract for anyÂ supplies orÂ services.Â Â The government will not pay for any information or administrative cost incurred in response to this Request for Information.Â Â Information will only be accepted in writing via email.\n\nDISCLAIMER:\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.Â Â Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.Â Â Responders are solely responsible for all expenses associated with responding to this RFI.Â","origin":"detail"},"contacts":[{"name":"Theresa Murray","role":"primary","email":"theresa.murray@va.gov","phone":"(814) 207-0348","title":"Contract Specialist"}],"place_of_performance":{"zip":"19805-2917","city":{"code":"77580","name":"Wilmington"},"state":{"code":"DE","name":"Delaware"},"street":"Wilmington VA Medical Center Dialysis Department","country":{"code":"USA","name":"UNITED STATES"},"street2":"1601 Kirkwood Hwy"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"cac1b1f9e99240abb82d9c87651c20d1","name":"36C24426Q0861.docx","kind":"file","mime_type":".docx","size_bytes":36618,"posted_at":"2026-08-04T18:10:10.313Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cac1b1f9e99240abb82d9c87651c20d1/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24427Q0073","latest_notice_id":"130d1e906067454a9520ca90284294e5","title":"J046--IDIQ | Deionization Water System Maintenance and Support","solicitation_number":"36C24427Q0073","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"221310","psc":"J046","set_aside":null,"state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":19,"indexable":false}