{"canonical":"https://sealedbidder.com/opportunities/36c24426q0631","key":"36C24426Q0631","url":"https://sealedbidder.com/opportunities/36c24426q0631","title":"6515--Leksell Vantage Stereotactic Instruments Brand name or Equal to This is not a request for quotes","solicitation_number":"36C24426Q0631","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-29T20:00:00Z","first_posted":"2026-05-22","last_posted":"2026-05-22","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339113","psc":"6515","set_aside":null,"place_state":"VA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"5c10e7c1618d457583b9d8b0f3a68523","title":"6515--Leksell Vantage Stereotactic Instruments Brand name or Equal to This is not a request for quotes","solicitation_number":"36C24426Q0631","notice_type":"r","base_type":"r","posted":"2026-05-22","posted_at":"2026-05-22T18:07:47.142Z","due_at":"2026-05-29T20:00:00Z","due_date":"2026-05-29","cancelled":false,"archived":true,"archive_date":"2026-06-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5c10e7c1618d457583b9d8b0f3a68523/view","enriched":true,"history":[{"index":3,"title":"6515--Leksell Vantage Stereotactic Instruments Brand name or Equal to This is not a request for quotes","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-22T18:07:47.142Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c10e7c1618d457583b9d8b0f3a68523","solicitation_number":"36C24426Q0631"}]}],"latest_notice_id":"5c10e7c1618d457583b9d8b0f3a68523","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-05-22","posted_at":"2026-05-22T18:07:47.142Z","created_at":"2026-05-22T18:07:44.862Z","modified_at":"2026-06-09T03:55:44.614Z","response_deadline":{"raw":"2026-05-29T16:00:00-04:00","utc":"2026-05-29T20:00:00Z","date":"2026-05-29","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5c10e7c1618d457583b9d8b0f3a68523/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Leksell Vantage Stereotactic Instruments Brand name or Equal to This is not a request for quotes","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Leksell Vantage Stereotactic Instruments Brand name or Equal to This is not a request for quotes","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-22T18:07:47.142Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c10e7c1618d457583b9d8b0f3a68523","solicitation_number":"36C24426Q0631"}],"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-679-2327","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"5c10e7c1618d457583b9d8b0f3a68523","lineage_id":"5c10e7c1618d457583b9d8b0f3a68523","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T03:27:26.256149441Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"39e674cf853e206cc9afc811d5a7917047a4ed6232c0f475ce7fd987c3e80b2f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-03T03:27:26.256149441Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Page 1 of \nPage 6 of 51\nPage 1 of \nStatement of Need \nThe Corporal Michael J. Crescenz VA Medical Center requires additional components for the Leksell stereotactic system specifically to enhance the capabilities for performing Deep Brain Stimulation (DBS) procedures at our facility. \nBackground \nDeep Brain Stimulation (DBS) is a recognized treatment for various neurological conditions, including Parkinson s disease, essential tremor, and dystonia. The procedure involves implanting electrodes within certain areas of the brain to produce electrical impulses that regulate abnormal impulses or affect certain cells and chemicals within the brain.\nCMC VAMC uses the Leksell stereotactic system for precise navigation and targeting during these intricate procedures. While the existing system provides a solid foundation, certain components must always have back-ups to maintain the highest standards of care, improve outcome accuracy, and expand the procedural capabilities in line with modern advancements in DBS.\nThe procurement and integration of these additional back-up components will have a profound impact on our service- delivery.\nSalient Characteristics/ Compatibility Requirements: Brand Name or Equal \n\nNeeds to be compatible with current Alpha Omega s Neuro Omega platform for Deep Brain Stimulation (DBS)\n\nAccuracy must be within 1 micron (.001 mm). \n\n\nMust filter, amplify, and digitize signals from the brain up to a foot away from patient head.\n\nMust minimize electromagnetic interference and other types of interference in the room\nMust be shielded with Tungsten or other equivalent material\n\nMust also measure Local Field potentials from each micro electrode on the implanted lead\n\nMust include\nSterilization tray for Drive Headstage and Cable\nECoG HeadBox\nHeadBox Cable\nHeadBox Holder\nTransformer Recording Only\n\nDrive and recording HeadStage must be one single assembly with electronic drive \nHeadStage must measure ECoG, EMG, EEG, and other electric signals from the body with up to 16 channels.\n10 Channels must be able to record unfiltered raw, high frequency spike and low frequency LFP signals.\nThere must be an ability to expand the amount of channels\nMust allow for trajectory adjustments without frame manipulation\n\nMust Drive up to 5 micro electrodes simultaneously\n\nMust utilize broadband filtering\n\nOnly 1 cable shall be utilized to connect headstage to Neuro Omega\nNo adaptors or connectors can be used\n\nHeadStage Drive and Cable must meet Robert Koch Institute recommendations for cleaning and sterilization of medical devices\n\nMust be usable with or without Stereotactic Frames\n\n\nMust be compatible with the following systems at a minimum\n\nRosa ONE Brain\nLeksel Frame\n\nMust allow for implantation of DBS Electrode without altering the position of the drive or removing cannulas.\n\nExample Brand Name or Equal Schedule \n\n1040051Leksell Vantage Key\n1EA\nAn instrument screw driver used with Leksell Vantage Stereotactic Arc System as well as with FirmFix pins during Leksell Vantage Head Frame Fixation.  Index bits Hex 3 and 4 are made of titanium while the rest of the Leksell Vantage Key is made of aluminum.\n1040025 Leksell Vantage Cross-Hairs\n1EA\nLeksell Vantage Cross-Hairs Kit in Stainless Steel is used with Leksell Vantage \nStereotactic System to intraoperatively check the placement of inserted \nelectrodes, catheters or other instruments in relation to the set target point.  The cross-hair has two parts. The cross plate has a thin pattern of a cross and the ring plate has a thin pattern of concentric rings. This difference makes it easy to find the line of sight in the X-ray images. Both the ring plate and the cross plate are equipped with rubber O-rings that ensure secure attachment to \nthe rings of the arc.  The cross-hairs is MR Unsafe.\n1040036 Leksell Vantage Head Frame \n1EA\nThis design of the head frame gives an open space in front of the face area. Therefore, \nit gives space for intubation of the patient if necessary in an emergency situation. The frame is MR Safe. The frame is designed for head sizes between 49 and 62 cm in circumference. The head width can be 134-175 mm in range and length 167-215 mm in range. The Leksell Vantage Key is used for FirmFix pin head frame fixation and for Leksell Vantage Stereotactic Arc target coordinate settings.  2 x Leksell Vantage Keys are included.\n1040048 Leksell Vantage Arc System\n1EA\nLeksell Vantage Arc System is designed to allow the surgeon to select any desired trajectory to the predetermined target, regardless of the patient\"s position, when using together with Leksell Vantage Head Frame.\nIt is used for diagnostic and therapeutic procedures, such as functional \ninterventions and minimal invasive neurosurgical procedures within its \nintended use.  The arc system is MR Conditional.\n1040045 Leksell Vantage Arc Tray\n1EA\nThe sterilization tray is used for the sterilization procedure of the parts of the \nLeksell Vantage Arc System, Leksell Vantage Key and Leksell Vantage Arc \nCross-Hairs.\n1040093 Vantage Starburst 3/8 \n1EA\nIncludes the Starburst interface for operating table base units with 3/8  screw interface, the starburst screw,\nand allen key 6 mm that are used to fix the starburst to the Leksell Vantage \nFrame Holder.\n1040114 Leksell Vantage Frame Holder\n1EA\nHolds the Leksell Vantage Head Frame in position when interfacing to \noperating tables and diagnostic CT scanner tables.\nIt is used in the operating theatre together with Starburst interfaces. It is also \nused during CT imaging where it is attached to the Leksell Vantage Frame \nHolder Extension.\n1556500 EN/Leksell  Vantage/QRG\n1EA\n\n1569126 EN/LVSS ARC System/QRG\n1EA\n\n1572849 EN-US/ Leksell Vantage System /IFU\n\n1EA\n\n\n\nREQUEST FOR INFORMATION   INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory.  It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below.  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture. \nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin \nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on May 29, 2026. This notice will help the VA in determining available potential sources only.  Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.  \nAll questions will be addressed by the Contracting Officer, Andrew Taylor.  Questions or responses will include the Source Sought number 36C24526Q0631 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request. \nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award.  This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information.  Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0631 in the subject line. \nDISCLAIMER \nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.  Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","text":"Page 1 of\nPage 6 of 51\nPage 1 of\nStatement of Need\nThe Corporal Michael J. Crescenz VA Medical Center requires additional components for the Leksell stereotactic system specifically to enhance the capabilities for performing Deep Brain Stimulation (DBS) procedures at our facility.\nBackground\nDeep Brain Stimulation (DBS) is a recognized treatment for various neurological conditions, including Parkinson s disease, essential tremor, and dystonia. The procedure involves implanting electrodes within certain areas of the brain to produce electrical impulses that regulate abnormal impulses or affect certain cells and chemicals within the brain.\nCMC VAMC uses the Leksell stereotactic system for precise navigation and targeting during these intricate procedures. While the existing system provides a solid foundation, certain components must always have back-ups to maintain the highest standards of care, improve outcome accuracy, and expand the procedural capabilities in line with modern advancements in DBS.\nThe procurement and integration of these additional back-up components will have a profound impact on our service- delivery.\nSalient Characteristics/ Compatibility Requirements: Brand Name or Equal\n\nNeeds to be compatible with current Alpha Omega s Neuro Omega platform for Deep Brain Stimulation (DBS)\n\nAccuracy must be within 1 micron (.001 mm).\n\nMust filter, amplify, and digitize signals from the brain up to a foot away from patient head.\n\nMust minimize electromagnetic interference and other types of interference in the room\nMust be shielded with Tungsten or other equivalent material\n\nMust also measure Local Field potentials from each micro electrode on the implanted lead\n\nMust include\nSterilization tray for Drive Headstage and Cable\nECoG HeadBox\nHeadBox Cable\nHeadBox Holder\nTransformer Recording Only\n\nDrive and recording HeadStage must be one single assembly with electronic drive\nHeadStage must measure ECoG, EMG, EEG, and other electric signals from the body with up to 16 channels.\n10 Channels must be able to record unfiltered raw, high frequency spike and low frequency LFP signals.\nThere must be an ability to expand the amount of channels\nMust allow for trajectory adjustments without frame manipulation\n\nMust Drive up to 5 micro electrodes simultaneously\n\nMust utilize broadband filtering\n\nOnly 1 cable shall be utilized to connect headstage to Neuro Omega\nNo adaptors or connectors can be used\n\nHeadStage Drive and Cable must meet Robert Koch Institute recommendations for cleaning and sterilization of medical devices\n\nMust be usable with or without Stereotactic Frames\n\nMust be compatible with the following systems at a minimum\n\nRosa ONE Brain\nLeksel Frame\n\nMust allow for implantation of DBS Electrode without altering the position of the drive or removing cannulas.\n\nExample Brand Name or Equal Schedule\n\n1040051Leksell Vantage Key\n1EA\nAn instrument screw driver used with Leksell Vantage Stereotactic Arc System as well as with FirmFix pins during Leksell Vantage Head Frame Fixation. Index bits Hex 3 and 4 are made of titanium while the rest of the Leksell Vantage Key is made of aluminum.\n1040025 Leksell Vantage Cross-Hairs\n1EA\nLeksell Vantage Cross-Hairs Kit in Stainless Steel is used with Leksell Vantage\nStereotactic System to intraoperatively check the placement of inserted\nelectrodes, catheters or other instruments in relation to the set target point. The cross-hair has two parts. The cross plate has a thin pattern of a cross and the ring plate has a thin pattern of concentric rings. This difference makes it easy to find the line of sight in the X-ray images. Both the ring plate and the cross plate are equipped with rubber O-rings that ensure secure attachment to\nthe rings of the arc. The cross-hairs is MR Unsafe.\n1040036 Leksell Vantage Head Frame\n1EA\nThis design of the head frame gives an open space in front of the face area. Therefore,\nit gives space for intubation of the patient if necessary in an emergency situation. The frame is MR Safe. The frame is designed for head sizes between 49 and 62 cm in circumference. The head width can be 134-175 mm in range and length 167-215 mm in range. The Leksell Vantage Key is used for FirmFix pin head frame fixation and for Leksell Vantage Stereotactic Arc target coordinate settings. 2 x Leksell Vantage Keys are included.\n1040048 Leksell Vantage Arc System\n1EA\nLeksell Vantage Arc System is designed to allow the surgeon to select any desired trajectory to the predetermined target, regardless of the patient\"s position, when using together with Leksell Vantage Head Frame.\nIt is used for diagnostic and therapeutic procedures, such as functional\ninterventions and minimal invasive neurosurgical procedures within its\nintended use. The arc system is MR Conditional.\n1040045 Leksell Vantage Arc Tray\n1EA\nThe sterilization tray is used for the sterilization procedure of the parts of the\nLeksell Vantage Arc System, Leksell Vantage Key and Leksell Vantage Arc\nCross-Hairs.\n1040093 Vantage Starburst 3/8\n1EA\nIncludes the Starburst interface for operating table base units with 3/8 screw interface, the starburst screw,\nand allen key 6 mm that are used to fix the starburst to the Leksell Vantage\nFrame Holder.\n1040114 Leksell Vantage Frame Holder\n1EA\nHolds the Leksell Vantage Head Frame in position when interfacing to\noperating tables and diagnostic CT scanner tables.\nIt is used in the operating theatre together with Starburst interfaces. It is also\nused during CT imaging where it is attached to the Leksell Vantage Frame\nHolder Extension.\n1556500 EN/Leksell Vantage/QRG\n1EA\n\n1569126 EN/LVSS ARC System/QRG\n1EA\n\n1572849 EN-US/ Leksell Vantage System /IFU\n\n1EA\n\nREQUEST FOR INFORMATION INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture.\nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin\nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on May 29, 2026. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.\nAll questions will be addressed by the Contracting Officer, Andrew Taylor. Questions or responses will include the Source Sought number 36C24526Q0631 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request.\nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0631 in the subject line.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24426Q0631","place_of_performance":{"zip":"19104","city":{"name":"Philadephia"},"state":{"code":"VA","name":"Virginia"},"street":"Corporal Michael Crescenz Philadelphia VA Medical Cener","country":{"code":"USA","name":"UNITED STATES"},"street2":"3900 Woodland Ave"},"product_service_code":"6515"}],"due_at":"2026-05-29T20:00:00Z","due_date":"2026-05-29","closes_at":"2026-05-29T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"VA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T03:55:19.037358Z","principal_notice_id":"5c10e7c1618d457583b9d8b0f3a68523","description":{"text":"Page 1 of\nPage 6 of 51\nPage 1 of\nStatement of Need\nThe Corporal Michael J. Crescenz VA Medical Center requires additional components for the Leksell stereotactic system specifically to enhance the capabilities for performing Deep Brain Stimulation (DBS) procedures at our facility.\nBackground\nDeep Brain Stimulation (DBS) is a recognized treatment for various neurological conditions, including Parkinson s disease, essential tremor, and dystonia. The procedure involves implanting electrodes within certain areas of the brain to produce electrical impulses that regulate abnormal impulses or affect certain cells and chemicals within the brain.\nCMC VAMC uses the Leksell stereotactic system for precise navigation and targeting during these intricate procedures. While the existing system provides a solid foundation, certain components must always have back-ups to maintain the highest standards of care, improve outcome accuracy, and expand the procedural capabilities in line with modern advancements in DBS.\nThe procurement and integration of these additional back-up components will have a profound impact on our service- delivery.\nSalient Characteristics/ Compatibility Requirements: Brand Name or Equal\n\nNeeds to be compatible with current Alpha Omega s Neuro Omega platform for Deep Brain Stimulation (DBS)\n\nAccuracy must be within 1 micron (.001 mm).\n\nMust filter, amplify, and digitize signals from the brain up to a foot away from patient head.\n\nMust minimize electromagnetic interference and other types of interference in the room\nMust be shielded with Tungsten or other equivalent material\n\nMust also measure Local Field potentials from each micro electrode on the implanted lead\n\nMust include\nSterilization tray for Drive Headstage and Cable\nECoG HeadBox\nHeadBox Cable\nHeadBox Holder\nTransformer Recording Only\n\nDrive and recording HeadStage must be one single assembly with electronic drive\nHeadStage must measure ECoG, EMG, EEG, and other electric signals from the body with up to 16 channels.\n10 Channels must be able to record unfiltered raw, high frequency spike and low frequency LFP signals.\nThere must be an ability to expand the amount of channels\nMust allow for trajectory adjustments without frame manipulation\n\nMust Drive up to 5 micro electrodes simultaneously\n\nMust utilize broadband filtering\n\nOnly 1 cable shall be utilized to connect headstage to Neuro Omega\nNo adaptors or connectors can be used\n\nHeadStage Drive and Cable must meet Robert Koch Institute recommendations for cleaning and sterilization of medical devices\n\nMust be usable with or without Stereotactic Frames\n\nMust be compatible with the following systems at a minimum\n\nRosa ONE Brain\nLeksel Frame\n\nMust allow for implantation of DBS Electrode without altering the position of the drive or removing cannulas.\n\nExample Brand Name or Equal Schedule\n\n1040051Leksell Vantage Key\n1EA\nAn instrument screw driver used with Leksell Vantage Stereotactic Arc System as well as with FirmFix pins during Leksell Vantage Head Frame Fixation. Index bits Hex 3 and 4 are made of titanium while the rest of the Leksell Vantage Key is made of aluminum.\n1040025 Leksell Vantage Cross-Hairs\n1EA\nLeksell Vantage Cross-Hairs Kit in Stainless Steel is used with Leksell Vantage\nStereotactic System to intraoperatively check the placement of inserted\nelectrodes, catheters or other instruments in relation to the set target point. The cross-hair has two parts. The cross plate has a thin pattern of a cross and the ring plate has a thin pattern of concentric rings. This difference makes it easy to find the line of sight in the X-ray images. Both the ring plate and the cross plate are equipped with rubber O-rings that ensure secure attachment to\nthe rings of the arc. The cross-hairs is MR Unsafe.\n1040036 Leksell Vantage Head Frame\n1EA\nThis design of the head frame gives an open space in front of the face area. Therefore,\nit gives space for intubation of the patient if necessary in an emergency situation. The frame is MR Safe. The frame is designed for head sizes between 49 and 62 cm in circumference. The head width can be 134-175 mm in range and length 167-215 mm in range. The Leksell Vantage Key is used for FirmFix pin head frame fixation and for Leksell Vantage Stereotactic Arc target coordinate settings. 2 x Leksell Vantage Keys are included.\n1040048 Leksell Vantage Arc System\n1EA\nLeksell Vantage Arc System is designed to allow the surgeon to select any desired trajectory to the predetermined target, regardless of the patient\"s position, when using together with Leksell Vantage Head Frame.\nIt is used for diagnostic and therapeutic procedures, such as functional\ninterventions and minimal invasive neurosurgical procedures within its\nintended use. The arc system is MR Conditional.\n1040045 Leksell Vantage Arc Tray\n1EA\nThe sterilization tray is used for the sterilization procedure of the parts of the\nLeksell Vantage Arc System, Leksell Vantage Key and Leksell Vantage Arc\nCross-Hairs.\n1040093 Vantage Starburst 3/8\n1EA\nIncludes the Starburst interface for operating table base units with 3/8 screw interface, the starburst screw,\nand allen key 6 mm that are used to fix the starburst to the Leksell Vantage\nFrame Holder.\n1040114 Leksell Vantage Frame Holder\n1EA\nHolds the Leksell Vantage Head Frame in position when interfacing to\noperating tables and diagnostic CT scanner tables.\nIt is used in the operating theatre together with Starburst interfaces. It is also\nused during CT imaging where it is attached to the Leksell Vantage Frame\nHolder Extension.\n1556500 EN/Leksell Vantage/QRG\n1EA\n\n1569126 EN/LVSS ARC System/QRG\n1EA\n\n1572849 EN-US/ Leksell Vantage System /IFU\n\n1EA\n\nREQUEST FOR INFORMATION INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture.\nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin\nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on May 29, 2026. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.\nAll questions will be addressed by the Contracting Officer, Andrew Taylor. Questions or responses will include the Source Sought number 36C24526Q0631 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request.\nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0631 in the subject line.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","html":"Page 1 of \nPage 6 of 51\nPage 1 of \nStatement of Need \nThe Corporal Michael J. Crescenz VA Medical Center requires additional components for the Leksell stereotactic system specifically to enhance the capabilities for performing Deep Brain Stimulation (DBS) procedures at our facility. \nBackground \nDeep Brain Stimulation (DBS) is a recognized treatment for various neurological conditions, including Parkinson s disease, essential tremor, and dystonia. The procedure involves implanting electrodes within certain areas of the brain to produce electrical impulses that regulate abnormal impulses or affect certain cells and chemicals within the brain.\nCMC VAMC uses the Leksell stereotactic system for precise navigation and targeting during these intricate procedures. While the existing system provides a solid foundation, certain components must always have back-ups to maintain the highest standards of care, improve outcome accuracy, and expand the procedural capabilities in line with modern advancements in DBS.\nThe procurement and integration of these additional back-up components will have a profound impact on our service- delivery.\nSalient Characteristics/ Compatibility Requirements: Brand Name or Equal \n\nNeeds to be compatible with current Alpha Omega s Neuro Omega platform for Deep Brain Stimulation (DBS)\n\nAccuracy must be within 1 micron (.001 mm). \n\n\nMust filter, amplify, and digitize signals from the brain up to a foot away from patient head.\n\nMust minimize electromagnetic interference and other types of interference in the room\nMust be shielded with Tungsten or other equivalent material\n\nMust also measure Local Field potentials from each micro electrode on the implanted lead\n\nMust include\nSterilization tray for Drive Headstage and Cable\nECoG HeadBox\nHeadBox Cable\nHeadBox Holder\nTransformer Recording Only\n\nDrive and recording HeadStage must be one single assembly with electronic drive \nHeadStage must measure ECoG, EMG, EEG, and other electric signals from the body with up to 16 channels.\n10 Channels must be able to record unfiltered raw, high frequency spike and low frequency LFP signals.\nThere must be an ability to expand the amount of channels\nMust allow for trajectory adjustments without frame manipulation\n\nMust Drive up to 5 micro electrodes simultaneously\n\nMust utilize broadband filtering\n\nOnly 1 cable shall be utilized to connect headstage to Neuro Omega\nNo adaptors or connectors can be used\n\nHeadStage Drive and Cable must meet Robert Koch Institute recommendations for cleaning and sterilization of medical devices\n\nMust be usable with or without Stereotactic Frames\n\n\nMust be compatible with the following systems at a minimum\n\nRosa ONE Brain\nLeksel Frame\n\nMust allow for implantation of DBS Electrode without altering the position of the drive or removing cannulas.\n\nExample Brand Name or Equal Schedule \n\n1040051Leksell Vantage Key\n1EA\nAn instrument screw driver used with Leksell Vantage Stereotactic Arc System as well as with FirmFix pins during Leksell Vantage Head Frame Fixation.  Index bits Hex 3 and 4 are made of titanium while the rest of the Leksell Vantage Key is made of aluminum.\n1040025 Leksell Vantage Cross-Hairs\n1EA\nLeksell Vantage Cross-Hairs Kit in Stainless Steel is used with Leksell Vantage \nStereotactic System to intraoperatively check the placement of inserted \nelectrodes, catheters or other instruments in relation to the set target point.  The cross-hair has two parts. The cross plate has a thin pattern of a cross and the ring plate has a thin pattern of concentric rings. This difference makes it easy to find the line of sight in the X-ray images. Both the ring plate and the cross plate are equipped with rubber O-rings that ensure secure attachment to \nthe rings of the arc.  The cross-hairs is MR Unsafe.\n1040036 Leksell Vantage Head Frame \n1EA\nThis design of the head frame gives an open space in front of the face area. Therefore, \nit gives space for intubation of the patient if necessary in an emergency situation. The frame is MR Safe. The frame is designed for head sizes between 49 and 62 cm in circumference. The head width can be 134-175 mm in range and length 167-215 mm in range. The Leksell Vantage Key is used for FirmFix pin head frame fixation and for Leksell Vantage Stereotactic Arc target coordinate settings.  2 x Leksell Vantage Keys are included.\n1040048 Leksell Vantage Arc System\n1EA\nLeksell Vantage Arc System is designed to allow the surgeon to select any desired trajectory to the predetermined target, regardless of the patient\"s position, when using together with Leksell Vantage Head Frame.\nIt is used for diagnostic and therapeutic procedures, such as functional \ninterventions and minimal invasive neurosurgical procedures within its \nintended use.  The arc system is MR Conditional.\n1040045 Leksell Vantage Arc Tray\n1EA\nThe sterilization tray is used for the sterilization procedure of the parts of the \nLeksell Vantage Arc System, Leksell Vantage Key and Leksell Vantage Arc \nCross-Hairs.\n1040093 Vantage Starburst 3/8 \n1EA\nIncludes the Starburst interface for operating table base units with 3/8  screw interface, the starburst screw,\nand allen key 6 mm that are used to fix the starburst to the Leksell Vantage \nFrame Holder.\n1040114 Leksell Vantage Frame Holder\n1EA\nHolds the Leksell Vantage Head Frame in position when interfacing to \noperating tables and diagnostic CT scanner tables.\nIt is used in the operating theatre together with Starburst interfaces. It is also \nused during CT imaging where it is attached to the Leksell Vantage Frame \nHolder Extension.\n1556500 EN/Leksell  Vantage/QRG\n1EA\n\n1569126 EN/LVSS ARC System/QRG\n1EA\n\n1572849 EN-US/ Leksell Vantage System /IFU\n\n1EA\n\n\n\nREQUEST FOR INFORMATION   INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory.  It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below.  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture. \nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin \nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on May 29, 2026. This notice will help the VA in determining available potential sources only.  Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.  \nAll questions will be addressed by the Contracting Officer, Andrew Taylor.  Questions or responses will include the Source Sought number 36C24526Q0631 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request. \nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award.  This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information.  Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0631 in the subject line. \nDISCLAIMER \nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.  Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","origin":"detail"},"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-679-2327","title":"Contracting Officer"}],"place_of_performance":{"zip":"19104","city":{"name":"Philadephia"},"state":{"code":"VA","name":"Virginia"},"street":"Corporal Michael Crescenz Philadelphia VA Medical Cener","country":{"code":"USA","name":"UNITED STATES"},"street2":"3900 Woodland Ave"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"218b26bd85b947f0bc9186ddd1b0b535","name":"36C24426Q0631.docx","kind":"file","mime_type":".docx","size_bytes":35659,"posted_at":"2026-05-22T18:07:47.142Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/218b26bd85b947f0bc9186ddd1b0b535/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24427Q0073","latest_notice_id":"130d1e906067454a9520ca90284294e5","title":"J046--IDIQ | Deionization Water System Maintenance and Support","solicitation_number":"36C24427Q0073","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"221310","psc":"J046","set_aside":null,"state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"IHSCSS11132026","latest_notice_id":"9299a096d7da4669945b92dbf7d8cb96","title":"ENDOMETRIAL ABLATION SURGICAL SUPPLIES","solicitation_number":"IHS-CSS11132026","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T20:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H711","office_name":"INDIAN HEALTH SERVICE","naics":"339113","psc":"6515","set_aside":"BICiv","state":"OK","county":"40031","county_name":"Comanche County","city":"4041850","city_name":"Lawton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":20,"indexable":false}