{"canonical":"https://sealedbidder.com/opportunities/36c24426q0611","key":"36C24426Q0611","url":"https://sealedbidder.com/opportunities/36c24426q0611","title":"6515--BCMA Scanners","solicitation_number":"36C24426Q0611","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-25T20:00:00Z","first_posted":"2026-05-18","last_posted":"2026-05-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"42031","place_county_name":"Clarion County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"57ba2ff42cf04393b207a088c6b406de","title":"6515--BCMA Scanners","solicitation_number":"36C24426Q0611","notice_type":"r","base_type":"r","posted":"2026-05-18","posted_at":"2026-05-18T12:52:25.441Z","due_at":"2026-05-25T20:00:00Z","due_date":"2026-05-25","cancelled":false,"archived":true,"archive_date":"2026-06-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/57ba2ff42cf04393b207a088c6b406de/view","enriched":true,"history":[{"index":3,"title":"6515--BCMA Scanners","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-18T12:52:25.441Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"57ba2ff42cf04393b207a088c6b406de","solicitation_number":"36C24426Q0611"}]}],"latest_notice_id":"57ba2ff42cf04393b207a088c6b406de","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-05-18","posted_at":"2026-05-18T12:52:25.441Z","created_at":"2026-05-18T12:52:23.231Z","modified_at":"2026-06-05T04:04:31.392Z","response_deadline":{"raw":"2026-05-25T16:00:00-04:00","utc":"2026-05-25T20:00:00Z","date":"2026-05-25","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/57ba2ff42cf04393b207a088c6b406de/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--BCMA Scanners","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-04","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--BCMA Scanners","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-18T12:52:25.441Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"57ba2ff42cf04393b207a088c6b406de","solicitation_number":"36C24426Q0611"}],"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-679-2327","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"57ba2ff42cf04393b207a088c6b406de","lineage_id":"57ba2ff42cf04393b207a088c6b406de","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T09:30:56.068669514Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6b1fa0b0f5aae4d3e098567508779083aeda28fffcfc0bbdda2c4ba4bb37287d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-03T09:30:56.068669514Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Department of Veterans Affairs\nErie VA Medical Center\nStatement of Need\n\nTitle: BCMA Scanners for Erie VAMC\nBackground:  The Erie Veterans Affairs Medical Center (Erie VAMC) has a brand-name or equal requirement for eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless Barcode Scanners.  This equipment is required to be in compliant with the VA Electronic Health Record Modernization (EHRM) initiative, ensuring the complete deployment of the EHRM at all VA medical facilities by 2031.  The EHRM will  Transform how VA delivers health care by implementing an enterprise-wide electronic health record (EHR) to standardize care across facilities, strengthen interoperability and collaboration with federal and community partners, foster innovation, improve provider and Veteran experiences, and ensure the continued delivery of high-quality, safe, and efficient health care to the nation s Veterans.   \nBrand name or Equal to:  The Erie VAMC requires eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless USB Barcode Scanners (or facility approved equivalents).  \nDescription\nPart #\nQty\nHoneywell, Xenon Ultra 1960H corded USB Healthcare Kit: White anti-microbial housing, HD focus, 1D/2D, PDF417, USB Type A 3M straight cable, vibration, NA/MX only, setup card, configured for Plug & Play use with VA BCMA System\n1960HHD-BCMA\n80\nHoneywell-based 1962HHD Ultra Cordless BCMA Firmware Scanner Kit: BCMA Firmware, setup card, FIPS 140-3, USB cable\n1962UHCF-CGS\n5\n\nSalient Characteristics (Minimum Required Capabilities): The vendor must provide all resources necessary to deliver the specified equipment in accordance with the below characteristics:\nGeneral Requirements:\nScanners shall be Cerner Validated for seamless integration with Oracle Health (Cerner) Millennium for medication administration, patient identification and data management.\nScanners must be constructed with disinfectant-ready materials capable of withstanding frequent cleaning with hospital-grade solutions\nScanners shall be pre-programmed to VA barcode medication administration (BCMA) Defaults.  Scannable set-up \"cheat sheet\" is acceptable\nScanners must be fully compatible with existing clinical applications, including electronic health record (EHR) systems and barcode medication administration (BCMA) workflows.\nScanners must not require significant modification to current IT infrastructure\nScanners shall include a minimum 3-year manufacturer warranty\nScanning Performance:\nScanners must be capable of reading 1D & 2D barcodes used in healthcare, including damaged, low-contrast or poorly printed codes\nScanners shall feature high-motion tolerance for fast-paced clinical environments\nScanners shall be capable of scanning from mobile device screens, patient wristbands and Barcode Medication Administration (BCMA)\nScanners shall include a patient-friendly (LED-based, not laser) aimer, suitable for healthcare settings\nErgonomics and Durability:\nScanners shall be lightweight and feature an ergonomic design suitable for extended clinical use\nScanners shall have a minimum drop resistance of six (6) feet to hard surface rating\nScanners shall be sealed to prevent ingress of dust and fluids, minimum IP41 rating or better.\nCorded Units (1960H Equivalent)\nScanners shall have USB connectivity compatible with existing workstation hardware\nScanners shall have plug-and-play functionality with minimal configuration required\nCordless Units (1962H Equivalent)\nScanners shall feature wireless connectivity, compliant with FIPS 140-2 or FIPS 140-3 (min level 1)\nScanners shall not require additional external hardware to meet FIPS compliance\nScanners shall have a minimum 10-meter communication range from scanner to cradle/base\nScanners shall have a rechargeable battery to support a full clinic shift\nScanners shall include a charging cradle, and be capable of charging the scanner through the USB cable without requiring additional power support\nTechnical Support   The vendor shall provide a Point of Contact (POC) name, phone number, and email address for technical support during the warranty period.\nPerformance Period:  Delivery shall occur within 30 days of contract award to Erie VAMC, located at 135 East 38TH Street, Erie, PA 16504.  \nWarranty   All equipment and materials shall come with a standard manufacturer warranty as a minimum.  Warranty shall begin after acceptance of equipment.\nDelivery   All items must be FOB Destination, 30 Days ARO, to: \nErie VA Medical Center \n135 East 38TH Street \nErie, PA 16504\nMonday   Friday, 8:00AM   4:00PM, excluding federal holidays\nTraining and Installation   The Erie VAMC does not require the vendor to perform any official or formal training or installation. Devices must be delivered ready for clinical use with all required accessories.\nSecurity & Privacy - The vendor will not be on station therefore the Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement, and a Security Accreditation package is not required. No C&A, MOU, or ISA is required.\nREQUEST FOR INFORMATION   INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory.  It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below.  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture. \nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin \nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on April 17, 2026. This notice will help the VA in determining available potential sources only.  Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.  \nAll questions will be addressed by the Contracting Officer, Andrew Taylor.  Questions or responses will include the Source Sought number 36C24526Q0611 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request. \nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award.  This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information.  Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0611 in the subject line. \nDISCLAIMER \nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.  Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","text":"Department of Veterans Affairs\nErie VA Medical Center\nStatement of Need\n\nTitle: BCMA Scanners for Erie VAMC\nBackground: The Erie Veterans Affairs Medical Center (Erie VAMC) has a brand-name or equal requirement for eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless Barcode Scanners. This equipment is required to be in compliant with the VA Electronic Health Record Modernization (EHRM) initiative, ensuring the complete deployment of the EHRM at all VA medical facilities by 2031. The EHRM will Transform how VA delivers health care by implementing an enterprise-wide electronic health record (EHR) to standardize care across facilities, strengthen interoperability and collaboration with federal and community partners, foster innovation, improve provider and Veteran experiences, and ensure the continued delivery of high-quality, safe, and efficient health care to the nation s Veterans.\nBrand name or Equal to: The Erie VAMC requires eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless USB Barcode Scanners (or facility approved equivalents).\nDescription\nPart #\nQty\nHoneywell, Xenon Ultra 1960H corded USB Healthcare Kit: White anti-microbial housing, HD focus, 1D/2D, PDF417, USB Type A 3M straight cable, vibration, NA/MX only, setup card, configured for Plug & Play use with VA BCMA System\n1960HHD-BCMA\n80\nHoneywell-based 1962HHD Ultra Cordless BCMA Firmware Scanner Kit: BCMA Firmware, setup card, FIPS 140-3, USB cable\n1962UHCF-CGS\n5\n\nSalient Characteristics (Minimum Required Capabilities): The vendor must provide all resources necessary to deliver the specified equipment in accordance with the below characteristics:\nGeneral Requirements:\nScanners shall be Cerner Validated for seamless integration with Oracle Health (Cerner) Millennium for medication administration, patient identification and data management.\nScanners must be constructed with disinfectant-ready materials capable of withstanding frequent cleaning with hospital-grade solutions\nScanners shall be pre-programmed to VA barcode medication administration (BCMA) Defaults. Scannable set-up \"cheat sheet\" is acceptable\nScanners must be fully compatible with existing clinical applications, including electronic health record (EHR) systems and barcode medication administration (BCMA) workflows.\nScanners must not require significant modification to current IT infrastructure\nScanners shall include a minimum 3-year manufacturer warranty\nScanning Performance:\nScanners must be capable of reading 1D & 2D barcodes used in healthcare, including damaged, low-contrast or poorly printed codes\nScanners shall feature high-motion tolerance for fast-paced clinical environments\nScanners shall be capable of scanning from mobile device screens, patient wristbands and Barcode Medication Administration (BCMA)\nScanners shall include a patient-friendly (LED-based, not laser) aimer, suitable for healthcare settings\nErgonomics and Durability:\nScanners shall be lightweight and feature an ergonomic design suitable for extended clinical use\nScanners shall have a minimum drop resistance of six (6) feet to hard surface rating\nScanners shall be sealed to prevent ingress of dust and fluids, minimum IP41 rating or better.\nCorded Units (1960H Equivalent)\nScanners shall have USB connectivity compatible with existing workstation hardware\nScanners shall have plug-and-play functionality with minimal configuration required\nCordless Units (1962H Equivalent)\nScanners shall feature wireless connectivity, compliant with FIPS 140-2 or FIPS 140-3 (min level 1)\nScanners shall not require additional external hardware to meet FIPS compliance\nScanners shall have a minimum 10-meter communication range from scanner to cradle/base\nScanners shall have a rechargeable battery to support a full clinic shift\nScanners shall include a charging cradle, and be capable of charging the scanner through the USB cable without requiring additional power support\nTechnical Support The vendor shall provide a Point of Contact (POC) name, phone number, and email address for technical support during the warranty period.\nPerformance Period: Delivery shall occur within 30 days of contract award to Erie VAMC, located at 135 East 38TH Street, Erie, PA 16504.\nWarranty All equipment and materials shall come with a standard manufacturer warranty as a minimum. Warranty shall begin after acceptance of equipment.\nDelivery All items must be FOB Destination, 30 Days ARO, to:\nErie VA Medical Center\n135 East 38TH Street\nErie, PA 16504\nMonday Friday, 8:00AM 4:00PM, excluding federal holidays\nTraining and Installation The Erie VAMC does not require the vendor to perform any official or formal training or installation. Devices must be delivered ready for clinical use with all required accessories.\nSecurity & Privacy - The vendor will not be on station therefore the Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement, and a Security Accreditation package is not required. No C&A, MOU, or ISA is required.\nREQUEST FOR INFORMATION INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture.\nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin\nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on April 17, 2026. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.\nAll questions will be addressed by the Contracting Officer, Andrew Taylor. Questions or responses will include the Source Sought number 36C24526Q0611 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request.\nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0611 in the subject line.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24426Q0611","place_of_performance":{"zip":"16054","city":{"name":"Erie"},"state":{"name":"PA"},"street":"Erie VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"135 E 38th St, Erie, PA 16504"},"product_service_code":"6515"}],"due_at":"2026-05-25T20:00:00Z","due_date":"2026-05-25","closes_at":"2026-05-25T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":"42031","county_name":"Clarion County","city":null,"city_name":null,"country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T10:26:27.596687Z","principal_notice_id":"57ba2ff42cf04393b207a088c6b406de","description":{"text":"Department of Veterans Affairs\nErie VA Medical Center\nStatement of Need\n\nTitle: BCMA Scanners for Erie VAMC\nBackground: The Erie Veterans Affairs Medical Center (Erie VAMC) has a brand-name or equal requirement for eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless Barcode Scanners. This equipment is required to be in compliant with the VA Electronic Health Record Modernization (EHRM) initiative, ensuring the complete deployment of the EHRM at all VA medical facilities by 2031. The EHRM will Transform how VA delivers health care by implementing an enterprise-wide electronic health record (EHR) to standardize care across facilities, strengthen interoperability and collaboration with federal and community partners, foster innovation, improve provider and Veteran experiences, and ensure the continued delivery of high-quality, safe, and efficient health care to the nation s Veterans.\nBrand name or Equal to: The Erie VAMC requires eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless USB Barcode Scanners (or facility approved equivalents).\nDescription\nPart #\nQty\nHoneywell, Xenon Ultra 1960H corded USB Healthcare Kit: White anti-microbial housing, HD focus, 1D/2D, PDF417, USB Type A 3M straight cable, vibration, NA/MX only, setup card, configured for Plug & Play use with VA BCMA System\n1960HHD-BCMA\n80\nHoneywell-based 1962HHD Ultra Cordless BCMA Firmware Scanner Kit: BCMA Firmware, setup card, FIPS 140-3, USB cable\n1962UHCF-CGS\n5\n\nSalient Characteristics (Minimum Required Capabilities): The vendor must provide all resources necessary to deliver the specified equipment in accordance with the below characteristics:\nGeneral Requirements:\nScanners shall be Cerner Validated for seamless integration with Oracle Health (Cerner) Millennium for medication administration, patient identification and data management.\nScanners must be constructed with disinfectant-ready materials capable of withstanding frequent cleaning with hospital-grade solutions\nScanners shall be pre-programmed to VA barcode medication administration (BCMA) Defaults. Scannable set-up \"cheat sheet\" is acceptable\nScanners must be fully compatible with existing clinical applications, including electronic health record (EHR) systems and barcode medication administration (BCMA) workflows.\nScanners must not require significant modification to current IT infrastructure\nScanners shall include a minimum 3-year manufacturer warranty\nScanning Performance:\nScanners must be capable of reading 1D & 2D barcodes used in healthcare, including damaged, low-contrast or poorly printed codes\nScanners shall feature high-motion tolerance for fast-paced clinical environments\nScanners shall be capable of scanning from mobile device screens, patient wristbands and Barcode Medication Administration (BCMA)\nScanners shall include a patient-friendly (LED-based, not laser) aimer, suitable for healthcare settings\nErgonomics and Durability:\nScanners shall be lightweight and feature an ergonomic design suitable for extended clinical use\nScanners shall have a minimum drop resistance of six (6) feet to hard surface rating\nScanners shall be sealed to prevent ingress of dust and fluids, minimum IP41 rating or better.\nCorded Units (1960H Equivalent)\nScanners shall have USB connectivity compatible with existing workstation hardware\nScanners shall have plug-and-play functionality with minimal configuration required\nCordless Units (1962H Equivalent)\nScanners shall feature wireless connectivity, compliant with FIPS 140-2 or FIPS 140-3 (min level 1)\nScanners shall not require additional external hardware to meet FIPS compliance\nScanners shall have a minimum 10-meter communication range from scanner to cradle/base\nScanners shall have a rechargeable battery to support a full clinic shift\nScanners shall include a charging cradle, and be capable of charging the scanner through the USB cable without requiring additional power support\nTechnical Support The vendor shall provide a Point of Contact (POC) name, phone number, and email address for technical support during the warranty period.\nPerformance Period: Delivery shall occur within 30 days of contract award to Erie VAMC, located at 135 East 38TH Street, Erie, PA 16504.\nWarranty All equipment and materials shall come with a standard manufacturer warranty as a minimum. Warranty shall begin after acceptance of equipment.\nDelivery All items must be FOB Destination, 30 Days ARO, to:\nErie VA Medical Center\n135 East 38TH Street\nErie, PA 16504\nMonday Friday, 8:00AM 4:00PM, excluding federal holidays\nTraining and Installation The Erie VAMC does not require the vendor to perform any official or formal training or installation. Devices must be delivered ready for clinical use with all required accessories.\nSecurity & Privacy - The vendor will not be on station therefore the Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement, and a Security Accreditation package is not required. No C&A, MOU, or ISA is required.\nREQUEST FOR INFORMATION INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture.\nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin\nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on April 17, 2026. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.\nAll questions will be addressed by the Contracting Officer, Andrew Taylor. Questions or responses will include the Source Sought number 36C24526Q0611 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request.\nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0611 in the subject line.\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","html":"Department of Veterans Affairs\nErie VA Medical Center\nStatement of Need\n\nTitle: BCMA Scanners for Erie VAMC\nBackground:  The Erie Veterans Affairs Medical Center (Erie VAMC) has a brand-name or equal requirement for eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless Barcode Scanners.  This equipment is required to be in compliant with the VA Electronic Health Record Modernization (EHRM) initiative, ensuring the complete deployment of the EHRM at all VA medical facilities by 2031.  The EHRM will  Transform how VA delivers health care by implementing an enterprise-wide electronic health record (EHR) to standardize care across facilities, strengthen interoperability and collaboration with federal and community partners, foster innovation, improve provider and Veteran experiences, and ensure the continued delivery of high-quality, safe, and efficient health care to the nation s Veterans.   \nBrand name or Equal to:  The Erie VAMC requires eighty (80) Honeywell-based Xenon Ultra 1960H Corded USB Barcode Scanners, and five (5) Honeywell-based 1962HHD Ultra Cordless USB Barcode Scanners (or facility approved equivalents).  \nDescription\nPart #\nQty\nHoneywell, Xenon Ultra 1960H corded USB Healthcare Kit: White anti-microbial housing, HD focus, 1D/2D, PDF417, USB Type A 3M straight cable, vibration, NA/MX only, setup card, configured for Plug & Play use with VA BCMA System\n1960HHD-BCMA\n80\nHoneywell-based 1962HHD Ultra Cordless BCMA Firmware Scanner Kit: BCMA Firmware, setup card, FIPS 140-3, USB cable\n1962UHCF-CGS\n5\n\nSalient Characteristics (Minimum Required Capabilities): The vendor must provide all resources necessary to deliver the specified equipment in accordance with the below characteristics:\nGeneral Requirements:\nScanners shall be Cerner Validated for seamless integration with Oracle Health (Cerner) Millennium for medication administration, patient identification and data management.\nScanners must be constructed with disinfectant-ready materials capable of withstanding frequent cleaning with hospital-grade solutions\nScanners shall be pre-programmed to VA barcode medication administration (BCMA) Defaults.  Scannable set-up \"cheat sheet\" is acceptable\nScanners must be fully compatible with existing clinical applications, including electronic health record (EHR) systems and barcode medication administration (BCMA) workflows.\nScanners must not require significant modification to current IT infrastructure\nScanners shall include a minimum 3-year manufacturer warranty\nScanning Performance:\nScanners must be capable of reading 1D & 2D barcodes used in healthcare, including damaged, low-contrast or poorly printed codes\nScanners shall feature high-motion tolerance for fast-paced clinical environments\nScanners shall be capable of scanning from mobile device screens, patient wristbands and Barcode Medication Administration (BCMA)\nScanners shall include a patient-friendly (LED-based, not laser) aimer, suitable for healthcare settings\nErgonomics and Durability:\nScanners shall be lightweight and feature an ergonomic design suitable for extended clinical use\nScanners shall have a minimum drop resistance of six (6) feet to hard surface rating\nScanners shall be sealed to prevent ingress of dust and fluids, minimum IP41 rating or better.\nCorded Units (1960H Equivalent)\nScanners shall have USB connectivity compatible with existing workstation hardware\nScanners shall have plug-and-play functionality with minimal configuration required\nCordless Units (1962H Equivalent)\nScanners shall feature wireless connectivity, compliant with FIPS 140-2 or FIPS 140-3 (min level 1)\nScanners shall not require additional external hardware to meet FIPS compliance\nScanners shall have a minimum 10-meter communication range from scanner to cradle/base\nScanners shall have a rechargeable battery to support a full clinic shift\nScanners shall include a charging cradle, and be capable of charging the scanner through the USB cable without requiring additional power support\nTechnical Support   The vendor shall provide a Point of Contact (POC) name, phone number, and email address for technical support during the warranty period.\nPerformance Period:  Delivery shall occur within 30 days of contract award to Erie VAMC, located at 135 East 38TH Street, Erie, PA 16504.  \nWarranty   All equipment and materials shall come with a standard manufacturer warranty as a minimum.  Warranty shall begin after acceptance of equipment.\nDelivery   All items must be FOB Destination, 30 Days ARO, to: \nErie VA Medical Center \n135 East 38TH Street \nErie, PA 16504\nMonday   Friday, 8:00AM   4:00PM, excluding federal holidays\nTraining and Installation   The Erie VAMC does not require the vendor to perform any official or formal training or installation. Devices must be delivered ready for clinical use with all required accessories.\nSecurity & Privacy - The vendor will not be on station therefore the Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement, and a Security Accreditation package is not required. No C&A, MOU, or ISA is required.\nREQUEST FOR INFORMATION   INSTRUCTIONS:\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory.  It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, UEI Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339114 Please answer the following questions:\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\nIs your company considered small under the NAICS code identified under this RFI?\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\nIf not, can you provide additional information shown below.  This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers.\nDoes your company exceed 500 employees;\nPrimarily engaged in the retail or wholesale trade and normally sells the type of item being supplied;\nTake ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice;\nObtained an individual or class waiver?\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nIf you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\nMust have an authorized distributor letter from the original equipment manufacture. \nIf you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\nDoes your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\nIf you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\nGeneral pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\nPlease submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to  equal to items  to establish capabilities for planning purposes?\nPlease review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\nEquipment manufacture, Country of origin \nPlease provide your UEI number.\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 12. Telephone responses will not be accepted. Responses must be received via e-mail to andrew.taylor3@va.gov no later than, 4:00 PM Eastern Time (ET) on April 17, 2026. This notice will help the VA in determining available potential sources only.  Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action.  \nAll questions will be addressed by the Contracting Officer, Andrew Taylor.  Questions or responses will include the Source Sought number 36C24526Q0611 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for quotes, therefore will not be considered for a contract award from this request. \nAny interested business concern must submit a no longer that 10-page capability statement addressing its ability to meet the requirements listed above to Capability Statement shall include a statement regarding how the business concern is engaged in wholesale trade and normally sells the item being supplied and how the business concern will take ownership of the items being delivered. Vendors shall also provide certification, evidence that they are an authorized distributor of the Original Equipment Manufacturer.\nIf a solicitation is issued, information will be posted on the SAM web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award.  This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information.  Information will only be accepted in writing by e-mail to Contracting Officer at andrew.taylor3@va.gov include 36C24426Q0611 in the subject line. \nDISCLAIMER \nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly.  Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nEnd of Document","origin":"detail"},"contacts":[{"name":"Andrew Taylor","role":"primary","email":"andrew.taylor3@va.gov","phone":"724-679-2327","title":"Contracting Officer"}],"place_of_performance":{"zip":"16054","city":{"name":"Erie"},"state":{"name":"PA"},"street":"Erie VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"135 E 38th St, Erie, PA 16504"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"b35aea2a6aba4634b60fb981a549b179","name":"36C24426Q0611.docx","kind":"file","mime_type":".docx","size_bytes":31438,"posted_at":"2026-05-18T12:52:25.441Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b35aea2a6aba4634b60fb981a549b179/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24427Q0073","latest_notice_id":"130d1e906067454a9520ca90284294e5","title":"J046--IDIQ | Deionization Water System Maintenance and Support","solicitation_number":"36C24427Q0073","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"221310","psc":"J046","set_aside":null,"state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"W911S227U0170","latest_notice_id":"8e384efad4304afa9f8a55c7438674ba","title":"MEDICAL EQUIPMENT AND SUPPLIES","solicitation_number":"W911S227U0170","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-25T06:17:21.102542Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":17,"indexable":false}