{"canonical":"https://sealedbidder.com/opportunities/36c24426q0066","key":"36C24426Q0066","url":"https://sealedbidder.com/opportunities/36c24426q0066","title":"J065--INTENT TO SOLE SOURCE HILL ROM SERVINITY SERVICE AGREEMENT","solicitation_number":"36C24426Q0066","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-04T15:00:00Z","first_posted":"2025-10-28","last_posted":"2025-10-28","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"811210","psc":"J065","set_aside":null,"place_state":"PA","place_scope":"site","site":null,"place_state_source":"site","place_evidence":"CCORDANCE WITH FAR 12.102(A). THE ERIE VA MEDICAL CENTER","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"4722b5db5e1341c9b80c07d11e9c2a38","title":"J065--INTENT TO SOLE SOURCE HILL ROM SERVINITY SERVICE AGREEMENT","solicitation_number":"36C24426Q0066","notice_type":"s","base_type":"s","posted":"2025-10-28","posted_at":"2025-10-28T18:28:21.900Z","due_at":"2025-11-04T15:00:00Z","due_date":"2025-11-04","cancelled":false,"archived":true,"archive_date":"2025-11-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4722b5db5e1341c9b80c07d11e9c2a38/view","enriched":true,"history":[{"index":3,"title":"J065--INTENT TO SOLE SOURCE HILL ROM SERVINITY SERVICE AGREEMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-28T18:28:21.900Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4722b5db5e1341c9b80c07d11e9c2a38","solicitation_number":"36C24426Q0066"}]}],"latest_notice_id":"4722b5db5e1341c9b80c07d11e9c2a38","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-10-28","posted_at":"2025-10-28T18:28:21.900Z","created_at":"2025-10-28T18:28:19.675Z","modified_at":"2025-11-15T04:55:46.390Z","response_deadline":{"raw":"2025-11-04T10:00:00-05:00","utc":"2025-11-04T15:00:00Z","date":"2025-11-04","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4722b5db5e1341c9b80c07d11e9c2a38/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--INTENT TO SOLE SOURCE HILL ROM SERVINITY SERVICE AGREEMENT","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-14","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--INTENT TO SOLE SOURCE HILL ROM SERVINITY SERVICE AGREEMENT","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-28T18:28:21.900Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"4722b5db5e1341c9b80c07d11e9c2a38","solicitation_number":"36C24426Q0066"}],"contacts":[{"fax":"email only","name":"Thomas A. Cossentino","role":"primary","email":"thomas.cossentino@va.gov","phone":"email only","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"4722b5db5e1341c9b80c07d11e9c2a38","lineage_id":"4722b5db5e1341c9b80c07d11e9c2a38","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T03:40:18.685517525Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"c6ecffa5ba7582b267d73457444730018441768632029108d27be9f637b6e8da","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-24T03:40:18.685517525Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Notice of Intent to Sole Source\n\nThe Department of Veterans Affairs, Network Contracting Office 04 (NCO4), intends to negotiate on a sole source basis with Hillrom in accordance with FAR 12.102(a).\n\nThe Erie VA Medical Center (Erie VAMC) requires a service agreement providing Original Equipment Manufacturer (OEM) certified labor, OEM replacement parts, tools, test equipment, travel, and shipping, required to perform annual preventative maintenance (PM) and corrective maintenance (CM) services for 48 Centrella Smart+ Beds at the Erie VAMC. Services shall conform to the Hillrom SERVinity Complete Protection program.  \n\nThe anticipated contract will include a one-year base performance period, and four one-year option periods.  \nThis Notice of Intent is not a request for competitive proposals. Responsible sources may identify their interest, accompanied by supporting literature that clearly demonstrates capability to meet the performance requirements detailed below, to the Contracting Officer no later than 11/04/2025 at 10:00 AM Eastern Time. All responses must be sent by email to the Contracting Officer, Thomas Cossentino, at thomas.cossentino@va.gov. Responses must include  ISS 36C24426Q0066  in the subject line. Telephone responses or inquiries will not be accepted. Determination of procurement strategy based on responses to this notice is solely within the discretion of the Contracting Officer. The NAICS Code for this procurement is 811210, Electronic and Precision Equipment Repair and Maintenance.\n\nPERFORMANCE REQUIREMENTS:\n\nCovered Equipment: Forty-eight (48) Hill-Rom Centrella Smart+ Beds with MAX surfaces and their Ready Connect modules. Exclusions: Any third-party accessories, consumables such as pads, batteries, bladders, and hoses. \n\nServices shall conform to the Hill-Rom Complete Protection program and the following specific requirements: \n\nPreventive Maintenance (PM): performed annually, in accordance with OEM specifications, technical service manuals, and ANSI/AAMI standards. \nCorrective Maintenance (CM): On-call service, including emergency repairs, on-site labor, OEM parts replacement, and loaner provision if equipment cannot be repaired on-site.  \nParts and Labor: All replacement parts shall be OEM authorized, new or remanufactured to OEM standard, and installed by certified service personnel. Substitutions require COR approval. \nRemote Support: 24/7 remote technical support, remote diagnostics, firmware/software updates, asset tracking. \nOEM Service Reports: Contract shall provide service history reports generated through Hill-Rom s Computerized Maintenance Management System (CMMS). Reports will document preventive and corrective maintenance performed and will be delivered in PDF to Biomedical Engineering. \nService Levels: Emergency response within 24 hours; Routine repairs within 2 business days\n\nSpecific Tasks:\n\nPreventative Maintenance (PM) \nThe contractor shall perform annual PM on each covered Centrella Smart+ bed in accordance with Hill-Rom OEM service manuals. At a minimum, PM shall include the following tasks:  \nInspect Internal Components (mattress) \nInspect air blowers, mattress bladders and hoses\nCheck the mattress interior for moisture or stains \nInspect Bed Movement Functions\nInspect brakes, steering, and 5th wheel\nVerify powered drive system\nInspecting / Adjusting Movement Limits\nVerify/adjust: \nTrendelenburg \nAuto Contour\nChair\nHi-Low\nHead articulation\nFoot retraction/articulation\nSlideGuard feature\nInspect Safety Features\nInspect side rails\nVerify CPR feature\nVerify alerts/communications: \nSideCom Communication System\nBed Exit\nSafeView System\nWireless Connectivity\nScale System / Calibration\nCheck and calibrate the scale system to ensure accurate patient weight display \nBattery Backup\nConfirm battery activates when the bed is unplugged and has sufficient power\nConfirm caregiver controls function on battery backup\nElectrical Safety Certification: \nMeasure electrical leakage and ground resistance \nInspect power cord and line filter for damage\nFunctional Controls\nVerify caregiver and patient controls operate correctly\nImprove Appearance\nReplace labels and plastic parts\nCleaning/Lubrication/Adjustments\nClean, lubricate moving parts, and make necessary mechanical adjustment per OEM guidance\nDocumentation / Certification \n Record and provide PM documentation and checklists suitable for accreditation review per OEM. \nMust provide OEM certified PM checklist plus OEM Service Report generated via Hill-Rom s CMMS within three (3) business days of each PM. \nSoftware/Firmware\nApply OEM release firmware/software updated during PM \n\n Corrective Maintenance (CM)\nEmergency Repair\nOn-Site within 24 hours (Contracting Officer authorization required if outside contract coverage).\nRoutine Repair\nOn-Site within 2 business days.\nOn-site repairs include OEM parts and labor; if a unit cannot be repaired on-site, the Contractor will provide a loaner. \nOnly OEM authorized parts shall be used. \n\nTechnical Support \n24/7 remote technical support.\nRemote diagnostics and firmware updates.\n\nService Documentation:\nThe contractor shall provide to Biomedical Engineering within three (3) business days after each PM or CM event: \nOEM Service Report from CMMS \nOEM Certified PM Checklist\nDate/time of service\nEquipment serviced\nAction taken and parts replaced\nTest/calibration results (before/after)\nSignatures of contractor technician and VA Biomedical acceptance","text":"Notice of Intent to Sole Source\n\nThe Department of Veterans Affairs, Network Contracting Office 04 (NCO4), intends to negotiate on a sole source basis with Hillrom in accordance with FAR 12.102(a).\n\nThe Erie VA Medical Center (Erie VAMC) requires a service agreement providing Original Equipment Manufacturer (OEM) certified labor, OEM replacement parts, tools, test equipment, travel, and shipping, required to perform annual preventative maintenance (PM) and corrective maintenance (CM) services for 48 Centrella Smart+ Beds at the Erie VAMC. Services shall conform to the Hillrom SERVinity Complete Protection program.\n\nThe anticipated contract will include a one-year base performance period, and four one-year option periods.\nThis Notice of Intent is not a request for competitive proposals. Responsible sources may identify their interest, accompanied by supporting literature that clearly demonstrates capability to meet the performance requirements detailed below, to the Contracting Officer no later than 11/04/2025 at 10:00 AM Eastern Time. All responses must be sent by email to the Contracting Officer, Thomas Cossentino, at thomas.cossentino@va.gov. Responses must include ISS 36C24426Q0066 in the subject line. Telephone responses or inquiries will not be accepted. Determination of procurement strategy based on responses to this notice is solely within the discretion of the Contracting Officer. The NAICS Code for this procurement is 811210, Electronic and Precision Equipment Repair and Maintenance.\n\nPERFORMANCE REQUIREMENTS:\n\nCovered Equipment: Forty-eight (48) Hill-Rom Centrella Smart+ Beds with MAX surfaces and their Ready Connect modules. Exclusions: Any third-party accessories, consumables such as pads, batteries, bladders, and hoses.\n\nServices shall conform to the Hill-Rom Complete Protection program and the following specific requirements:\n\nPreventive Maintenance (PM): performed annually, in accordance with OEM specifications, technical service manuals, and ANSI/AAMI standards.\nCorrective Maintenance (CM): On-call service, including emergency repairs, on-site labor, OEM parts replacement, and loaner provision if equipment cannot be repaired on-site.\nParts and Labor: All replacement parts shall be OEM authorized, new or remanufactured to OEM standard, and installed by certified service personnel. Substitutions require COR approval.\nRemote Support: 24/7 remote technical support, remote diagnostics, firmware/software updates, asset tracking.\nOEM Service Reports: Contract shall provide service history reports generated through Hill-Rom s Computerized Maintenance Management System (CMMS). Reports will document preventive and corrective maintenance performed and will be delivered in PDF to Biomedical Engineering.\nService Levels: Emergency response within 24 hours; Routine repairs within 2 business days\n\nSpecific Tasks:\n\nPreventative Maintenance (PM)\nThe contractor shall perform annual PM on each covered Centrella Smart+ bed in accordance with Hill-Rom OEM service manuals. At a minimum, PM shall include the following tasks:\nInspect Internal Components (mattress)\nInspect air blowers, mattress bladders and hoses\nCheck the mattress interior for moisture or stains\nInspect Bed Movement Functions\nInspect brakes, steering, and 5th wheel\nVerify powered drive system\nInspecting / Adjusting Movement Limits\nVerify/adjust:\nTrendelenburg\nAuto Contour\nChair\nHi-Low\nHead articulation\nFoot retraction/articulation\nSlideGuard feature\nInspect Safety Features\nInspect side rails\nVerify CPR feature\nVerify alerts/communications:\nSideCom Communication System\nBed Exit\nSafeView System\nWireless Connectivity\nScale System / Calibration\nCheck and calibrate the scale system to ensure accurate patient weight display\nBattery Backup\nConfirm battery activates when the bed is unplugged and has sufficient power\nConfirm caregiver controls function on battery backup\nElectrical Safety Certification:\nMeasure electrical leakage and ground resistance\nInspect power cord and line filter for damage\nFunctional Controls\nVerify caregiver and patient controls operate correctly\nImprove Appearance\nReplace labels and plastic parts\nCleaning/Lubrication/Adjustments\nClean, lubricate moving parts, and make necessary mechanical adjustment per OEM guidance\nDocumentation / Certification\nRecord and provide PM documentation and checklists suitable for accreditation review per OEM.\nMust provide OEM certified PM checklist plus OEM Service Report generated via Hill-Rom s CMMS within three (3) business days of each PM.\nSoftware/Firmware\nApply OEM release firmware/software updated during PM\n\nCorrective Maintenance (CM)\nEmergency Repair\nOn-Site within 24 hours (Contracting Officer authorization required if outside contract coverage).\nRoutine Repair\nOn-Site within 2 business days.\nOn-site repairs include OEM parts and labor; if a unit cannot be repaired on-site, the Contractor will provide a loaner.\nOnly OEM authorized parts shall be used.\n\nTechnical Support\n24/7 remote technical support.\nRemote diagnostics and firmware updates.\n\nService Documentation:\nThe contractor shall provide to Biomedical Engineering within three (3) business days after each PM or CM event:\nOEM Service Report from CMMS\nOEM Certified PM Checklist\nDate/time of service\nEquipment serviced\nAction taken and parts replaced\nTest/calibration results (before/after)\nSignatures of contractor technician and VA Biomedical acceptance","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24426Q0066","product_service_code":"J065"}],"due_at":"2025-11-04T15:00:00Z","due_date":"2025-11-04","closes_at":"2025-11-04T15:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"site","state_evidence":"CCORDANCE WITH FAR 12.102(A). THE ERIE VA MEDICAL CENTER","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-24T03:56:54.139438Z","principal_notice_id":"4722b5db5e1341c9b80c07d11e9c2a38","description":{"text":"Notice of Intent to Sole Source\n\nThe Department of Veterans Affairs, Network Contracting Office 04 (NCO4), intends to negotiate on a sole source basis with Hillrom in accordance with FAR 12.102(a).\n\nThe Erie VA Medical Center (Erie VAMC) requires a service agreement providing Original Equipment Manufacturer (OEM) certified labor, OEM replacement parts, tools, test equipment, travel, and shipping, required to perform annual preventative maintenance (PM) and corrective maintenance (CM) services for 48 Centrella Smart+ Beds at the Erie VAMC. Services shall conform to the Hillrom SERVinity Complete Protection program.\n\nThe anticipated contract will include a one-year base performance period, and four one-year option periods.\nThis Notice of Intent is not a request for competitive proposals. Responsible sources may identify their interest, accompanied by supporting literature that clearly demonstrates capability to meet the performance requirements detailed below, to the Contracting Officer no later than 11/04/2025 at 10:00 AM Eastern Time. All responses must be sent by email to the Contracting Officer, Thomas Cossentino, at thomas.cossentino@va.gov. Responses must include ISS 36C24426Q0066 in the subject line. Telephone responses or inquiries will not be accepted. Determination of procurement strategy based on responses to this notice is solely within the discretion of the Contracting Officer. The NAICS Code for this procurement is 811210, Electronic and Precision Equipment Repair and Maintenance.\n\nPERFORMANCE REQUIREMENTS:\n\nCovered Equipment: Forty-eight (48) Hill-Rom Centrella Smart+ Beds with MAX surfaces and their Ready Connect modules. Exclusions: Any third-party accessories, consumables such as pads, batteries, bladders, and hoses.\n\nServices shall conform to the Hill-Rom Complete Protection program and the following specific requirements:\n\nPreventive Maintenance (PM): performed annually, in accordance with OEM specifications, technical service manuals, and ANSI/AAMI standards.\nCorrective Maintenance (CM): On-call service, including emergency repairs, on-site labor, OEM parts replacement, and loaner provision if equipment cannot be repaired on-site.\nParts and Labor: All replacement parts shall be OEM authorized, new or remanufactured to OEM standard, and installed by certified service personnel. Substitutions require COR approval.\nRemote Support: 24/7 remote technical support, remote diagnostics, firmware/software updates, asset tracking.\nOEM Service Reports: Contract shall provide service history reports generated through Hill-Rom s Computerized Maintenance Management System (CMMS). Reports will document preventive and corrective maintenance performed and will be delivered in PDF to Biomedical Engineering.\nService Levels: Emergency response within 24 hours; Routine repairs within 2 business days\n\nSpecific Tasks:\n\nPreventative Maintenance (PM)\nThe contractor shall perform annual PM on each covered Centrella Smart+ bed in accordance with Hill-Rom OEM service manuals. At a minimum, PM shall include the following tasks:\nInspect Internal Components (mattress)\nInspect air blowers, mattress bladders and hoses\nCheck the mattress interior for moisture or stains\nInspect Bed Movement Functions\nInspect brakes, steering, and 5th wheel\nVerify powered drive system\nInspecting / Adjusting Movement Limits\nVerify/adjust:\nTrendelenburg\nAuto Contour\nChair\nHi-Low\nHead articulation\nFoot retraction/articulation\nSlideGuard feature\nInspect Safety Features\nInspect side rails\nVerify CPR feature\nVerify alerts/communications:\nSideCom Communication System\nBed Exit\nSafeView System\nWireless Connectivity\nScale System / Calibration\nCheck and calibrate the scale system to ensure accurate patient weight display\nBattery Backup\nConfirm battery activates when the bed is unplugged and has sufficient power\nConfirm caregiver controls function on battery backup\nElectrical Safety Certification:\nMeasure electrical leakage and ground resistance\nInspect power cord and line filter for damage\nFunctional Controls\nVerify caregiver and patient controls operate correctly\nImprove Appearance\nReplace labels and plastic parts\nCleaning/Lubrication/Adjustments\nClean, lubricate moving parts, and make necessary mechanical adjustment per OEM guidance\nDocumentation / Certification\nRecord and provide PM documentation and checklists suitable for accreditation review per OEM.\nMust provide OEM certified PM checklist plus OEM Service Report generated via Hill-Rom s CMMS within three (3) business days of each PM.\nSoftware/Firmware\nApply OEM release firmware/software updated during PM\n\nCorrective Maintenance (CM)\nEmergency Repair\nOn-Site within 24 hours (Contracting Officer authorization required if outside contract coverage).\nRoutine Repair\nOn-Site within 2 business days.\nOn-site repairs include OEM parts and labor; if a unit cannot be repaired on-site, the Contractor will provide a loaner.\nOnly OEM authorized parts shall be used.\n\nTechnical Support\n24/7 remote technical support.\nRemote diagnostics and firmware updates.\n\nService Documentation:\nThe contractor shall provide to Biomedical Engineering within three (3) business days after each PM or CM event:\nOEM Service Report from CMMS\nOEM Certified PM Checklist\nDate/time of service\nEquipment serviced\nAction taken and parts replaced\nTest/calibration results (before/after)\nSignatures of contractor technician and VA Biomedical acceptance","html":"Notice of Intent to Sole Source\n\nThe Department of Veterans Affairs, Network Contracting Office 04 (NCO4), intends to negotiate on a sole source basis with Hillrom in accordance with FAR 12.102(a).\n\nThe Erie VA Medical Center (Erie VAMC) requires a service agreement providing Original Equipment Manufacturer (OEM) certified labor, OEM replacement parts, tools, test equipment, travel, and shipping, required to perform annual preventative maintenance (PM) and corrective maintenance (CM) services for 48 Centrella Smart+ Beds at the Erie VAMC. Services shall conform to the Hillrom SERVinity Complete Protection program.  \n\nThe anticipated contract will include a one-year base performance period, and four one-year option periods.  \nThis Notice of Intent is not a request for competitive proposals. Responsible sources may identify their interest, accompanied by supporting literature that clearly demonstrates capability to meet the performance requirements detailed below, to the Contracting Officer no later than 11/04/2025 at 10:00 AM Eastern Time. All responses must be sent by email to the Contracting Officer, Thomas Cossentino, at thomas.cossentino@va.gov. Responses must include  ISS 36C24426Q0066  in the subject line. Telephone responses or inquiries will not be accepted. Determination of procurement strategy based on responses to this notice is solely within the discretion of the Contracting Officer. The NAICS Code for this procurement is 811210, Electronic and Precision Equipment Repair and Maintenance.\n\nPERFORMANCE REQUIREMENTS:\n\nCovered Equipment: Forty-eight (48) Hill-Rom Centrella Smart+ Beds with MAX surfaces and their Ready Connect modules. Exclusions: Any third-party accessories, consumables such as pads, batteries, bladders, and hoses. \n\nServices shall conform to the Hill-Rom Complete Protection program and the following specific requirements: \n\nPreventive Maintenance (PM): performed annually, in accordance with OEM specifications, technical service manuals, and ANSI/AAMI standards. \nCorrective Maintenance (CM): On-call service, including emergency repairs, on-site labor, OEM parts replacement, and loaner provision if equipment cannot be repaired on-site.  \nParts and Labor: All replacement parts shall be OEM authorized, new or remanufactured to OEM standard, and installed by certified service personnel. Substitutions require COR approval. \nRemote Support: 24/7 remote technical support, remote diagnostics, firmware/software updates, asset tracking. \nOEM Service Reports: Contract shall provide service history reports generated through Hill-Rom s Computerized Maintenance Management System (CMMS). Reports will document preventive and corrective maintenance performed and will be delivered in PDF to Biomedical Engineering. \nService Levels: Emergency response within 24 hours; Routine repairs within 2 business days\n\nSpecific Tasks:\n\nPreventative Maintenance (PM) \nThe contractor shall perform annual PM on each covered Centrella Smart+ bed in accordance with Hill-Rom OEM service manuals. At a minimum, PM shall include the following tasks:  \nInspect Internal Components (mattress) \nInspect air blowers, mattress bladders and hoses\nCheck the mattress interior for moisture or stains \nInspect Bed Movement Functions\nInspect brakes, steering, and 5th wheel\nVerify powered drive system\nInspecting / Adjusting Movement Limits\nVerify/adjust: \nTrendelenburg \nAuto Contour\nChair\nHi-Low\nHead articulation\nFoot retraction/articulation\nSlideGuard feature\nInspect Safety Features\nInspect side rails\nVerify CPR feature\nVerify alerts/communications: \nSideCom Communication System\nBed Exit\nSafeView System\nWireless Connectivity\nScale System / Calibration\nCheck and calibrate the scale system to ensure accurate patient weight display \nBattery Backup\nConfirm battery activates when the bed is unplugged and has sufficient power\nConfirm caregiver controls function on battery backup\nElectrical Safety Certification: \nMeasure electrical leakage and ground resistance \nInspect power cord and line filter for damage\nFunctional Controls\nVerify caregiver and patient controls operate correctly\nImprove Appearance\nReplace labels and plastic parts\nCleaning/Lubrication/Adjustments\nClean, lubricate moving parts, and make necessary mechanical adjustment per OEM guidance\nDocumentation / Certification \n Record and provide PM documentation and checklists suitable for accreditation review per OEM. \nMust provide OEM certified PM checklist plus OEM Service Report generated via Hill-Rom s CMMS within three (3) business days of each PM. \nSoftware/Firmware\nApply OEM release firmware/software updated during PM \n\n Corrective Maintenance (CM)\nEmergency Repair\nOn-Site within 24 hours (Contracting Officer authorization required if outside contract coverage).\nRoutine Repair\nOn-Site within 2 business days.\nOn-site repairs include OEM parts and labor; if a unit cannot be repaired on-site, the Contractor will provide a loaner. \nOnly OEM authorized parts shall be used. \n\nTechnical Support \n24/7 remote technical support.\nRemote diagnostics and firmware updates.\n\nService Documentation:\nThe contractor shall provide to Biomedical Engineering within three (3) business days after each PM or CM event: \nOEM Service Report from CMMS \nOEM Certified PM Checklist\nDate/time of service\nEquipment serviced\nAction taken and parts replaced\nTest/calibration results (before/after)\nSignatures of contractor technician and VA Biomedical acceptance","origin":"detail"},"contacts":[{"fax":"email only","name":"Thomas A. Cossentino","role":"primary","email":"thomas.cossentino@va.gov","phone":"email only","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"a1ce134fe3a044bda5d469081e03975e","name":"36C24426Q0066.docx","kind":"file","mime_type":".docx","size_bytes":20023,"posted_at":"2025-10-28T18:28:21.900Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a1ce134fe3a044bda5d469081e03975e/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24427Q0053","latest_notice_id":"7935eeaee4d94638addddf105e1e7449","title":"Q510--Bedside Somatosensory Evoked Potential (SSEP) Studies VA Pittsburgh Healthcare System","solicitation_number":"36C24427Q0053","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"621399","psc":"Q510","set_aside":null,"state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":"15240","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T01:26:57.794874Z"}],"similar_open":[{"key":"B8164D58E343480FAF72E235E2A2B7BA","latest_notice_id":"4badf0faa275492a8898366f3cfcb4f9","title":"Notice of Intent to Sole Source - SmartLab X-ray Diffractometer (XRD) Service Agreement - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"W51AA127QA004","latest_notice_id":"8fe637fd4a2e485d9897807458fad1e1","title":"400 Hz Cycle Converters - Maintenance, Inspections, and Repairs","solicitation_number":"W51AA127QA004","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-14T21:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51AA1","office_name":"W6QK ACC-APG CONT CT TYAD OFC","naics":"811210","psc":"J059","set_aside":"SBA","state":"PA","county":"42089","county_name":"Monroe County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open_total":63,"indexable":false}