{"canonical":"https://sealedbidder.com/opportunities/36c24426q0023","key":"36C24426Q0023","url":"https://sealedbidder.com/opportunities/36c24426q0023","title":"J046--642-26-1-583-0011 | SEA 26545 | Deionized Water System Lease and PM&R Services","solicitation_number":"36C24426Q0023","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-10-22T06:00:00Z","first_posted":"2025-10-07","last_posted":"2025-10-07","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"811210","psc":"J046","set_aside":null,"place_state":"PA","place_scope":"site","site":null,"place_state_source":"site","place_evidence":"ENT OF VETERAN AFFAIRS MICHAEL J CRESCENZ VA MEDICAL CENTER","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"a22d52788e464e5cbb9d391a8cec8e2b","title":"J046--642-26-1-583-0011 | SEA 26545 | Deionized Water System Lease and PM&R Services","solicitation_number":"36C24426Q0023","notice_type":"s","base_type":"s","posted":"2025-10-07","posted_at":"2025-10-07T17:25:58.686Z","due_at":"2025-10-22T06:00:00Z","due_date":"2025-10-22","cancelled":false,"archived":true,"archive_date":"2025-11-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a22d52788e464e5cbb9d391a8cec8e2b/view","enriched":true,"history":[{"index":3,"title":"J046--642-26-1-583-0011 | SEA 26545 | Deionized Water System Lease and PM&R Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-07T17:25:58.686Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a22d52788e464e5cbb9d391a8cec8e2b","solicitation_number":"36C24426Q0023"}]}],"latest_notice_id":"a22d52788e464e5cbb9d391a8cec8e2b","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-10-07","posted_at":"2025-10-07T17:25:58.686Z","created_at":"2025-10-07T17:25:56.535Z","modified_at":"2025-11-07T05:04:27.463Z","response_deadline":{"raw":"2025-10-22T02:00:00-04:00","utc":"2025-10-22T06:00:00Z","date":"2025-10-22","time":"02:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a22d52788e464e5cbb9d391a8cec8e2b/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J046--642-26-1-583-0011 | SEA 26545 | Deionized Water System Lease and PM&R Services","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"J046--642-26-1-583-0011 | SEA 26545 | Deionized Water System Lease and PM&R Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-07T17:25:58.686Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a22d52788e464e5cbb9d391a8cec8e2b","solicitation_number":"36C24426Q0023"}],"contacts":[{"name":"DEREK M CHUFF","role":"primary","email":"DEREK.CHUFF@va.gov","phone":"814-943-8164","title":"Derek.Chuff@va.gov"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"a22d52788e464e5cbb9d391a8cec8e2b","lineage_id":"a22d52788e464e5cbb9d391a8cec8e2b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-27T00:29:34.060608589Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"6b6ee512d66a46b35503258c1278a5ff66bf66437c85ffc2b3b49a8a6e12dbae","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-27T00:29:34.060608589Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Department of Veteran Affairs Michael J Crescenz VA Medical Center\nPerformance Work Statement  - Sterile Processing Service \nMaintenance Service Contract for Deionized (DI)  Water\n\n1.0 Introduction\nThe Michael J Crescenz VA Medical Center, Sterile Processing Services (SPS) requires critical modifications to the existing DI water equipment supplied by Evoqua. These modifications will provide new equipment and additional tanks to adhere to the standards defined by  Advancement of Medical Instrumentaiton (AAMI) ST-108.  \nThis scope of work is to provide services contract for the initial installation, operations and maintenance service contract  for Deionized (DI) Water for Sterile Processing Services areas (SPS) the VA Medical Center to be compliant with the standards defined in this performance work statement. This service contract will be issued as a  3-Year Service Contract.\nThe Contractor shall provide all personnel, equipment, materials, facilities, transportation, tools, water testing services, and supervision to perform these operations and maintenance services to adhere to AAMI ST-108.\n\n2.0 Objective\nThe equipment installed under this contract will be part of a (3) year service maintenance contract.  The vendor will be required to provide on-site maintenance to ensure all equipment maintenance and exchanges (DI units, filtration, UV sterilization) will process DI water to meet ST-108 standards.\n\nGiven the critical nature of the instruments SPS sterilizes, there is a direct impact on the operations of Surgery, Ear, Nose, & Throat (ENT), and Gastrointestinal (GI). \n\nAll work must be completed on Saturday.  A fully operational and validated system must be completed in one day.    \n\nScope \nDesign & Installation\nRemoval of existing Evoqua systems in SPS Mechanical Room.  Refer to Attachment A for layout of existing equipment. \nAll Evoqua equipment removed will be disposed of off-site.\nThe VA supplied SPS  DI water utilization will be the basis for design of the system.  \nThe system will be designed to meet the DI water capacity  where anion, cation, and carbon tanks will be replaced every 30 days.  The system design is based on the most stringent conditions of high conductivity (total dissolved solids) for the in-coming water during the winter months  and DI water usage of 11,000 gallons per month. \n(2) carbon tanks\n(9) exchange tanks\nThe existing DI  pipe (1.5 inch diameter ) for the supply and the return will remain.  Vendor will attach the system connections to the supply and return line. \nThe VA will create a smaller DI supply and return loop (3/4 ) for sinks #2 and #3.  The loop will generate at the DI Skid and return at the skid. Vendor will provide the connections to the DI skid\nSystem will provide primary filter and housing (20 inch) 5 micron\nSystem will provide secondary filter and housing (20 inch) 1 micron\nSystem will provide final filter and housing (20 inch) 0.2 micron\nBacteria destruct ultraviolet sterilization\nFeed & final water quality sensor \nCheck valves on supply and return lines\nFlow meter on supply and return lines\nMain control panel  to provide centralized, automated control and monitoring of the entire purification process. System will monitor water quality and manage maintenance cycles.Â \nRecirculation pumps on supply and return lines\nTest valves  for water testing validation\n Drain & isolation  valves for maintenance\nCheck valves to present reverse flow within system \nThe exchange tanks will be placed in the SPS mechanical room.  The remaining equipment will be supplied with a skid mount system placed outside the mechanical room.  Hoses will be attached from the skid mount system to the tanks.  The VA will  provide the open wall section for these hose connections inside the mechanical room.  See Sketch 1.\nVendor shall provide ST-108 compliant water testing services for Sterile Processing. \n\n Commissioning \nInspect, test, and verify the system's performance to ensure it meets design objectives to consistently produce  DI water to meet ST-108 standards\nQualifications & Inspection\nVerifying the system is installed according to design standards.\nVisual inspection, Pre-treatment checks, Performance tests for flow rate and water conductivity\nCalibration of monitoring instruments\nFinal verification and on-site operator training\nFunctional Testing\nPerformance Testing:Â Measuring the system's flow rate and water conductivity to confirm it meets the required purity standards \nCalibration:Â Calibrating all monitoring instruments, such as resistance meters and flow meters.\nIntegrated System Testing:Â Operating the entire system to ensure all parts work together correctly.\n\nPost-Commissioning\nFinal Verification:Â A final confirmation that the system meets all established criteria and standards.\nInitial Water testing at points of use on the DI system  to meet ST-108 requirements.  See Attachment B\nOperator Training:Â Providing on-site training\nDocumentation:Â Documenting all test results and the entire commissioning process for future reference and compliance.\nMonitoring & Break-in Period:Â A continuous water sampling and testing period, often 2-4 weeks) is sometimes recommended to monitor performance\n\nMaintenance and Repair\nAll maintenance work  shall ensure continuous system operation and compliance to ST-108\nRoutine checks and replacement of filter  and UV lamps\nAddressing leaks at hoses and connections\nPumps - replacing worn components \nResin Replacement/Regeneration: replace as required.  Design is based on 30-day cycle.  Should operation or incoming water conductivity affect higher utilization of tanks, these will be switched next day, which could occur on a weekend. \nInstrument Calibration: Conductivity sensors and other instruments need periodic calibration to ensure accurate water quality monitoring.Â \nLeak Checks: Inspect tanks and piping networks for leaks to prevent contamination and system downtime.Â \nSanitization: Periodically clean and flush the system to remove biofilms and prevent bacterial growth.Â \nAll work scheduled work will be performed Monday   Friday  5AM   7AM.  Any work requiring more that (2) hours shall be performed on a Saturday \nQuarterly DI loop sanitization.\n\n\nWater Testing Requirements\nVendor shall furnish all personnel, supervision, certifications, materials, equipment, facilities, results, and resources necessary for water sampling of all locations and frequencies outlined in Attachment B in accordance with ANSI/AAMI ST108 for Sterile Processing.  The water quality required from this DI generation system is used for the various stages of medical device processing.  Water test results validate system operation for water quality measurement values per ANSI/AAMI ST108 are outlined in Attachment B. \nAseptic technique should be used for water collection.  This technique is Â a set of procedures designed to prevent contamination from microorganisms, especially bacteria, viruses, and other pathogens.Â It's a crucial practice in healthcare, laboratory settings, and manufacturing to protect patients, personnel, and products from infections.Â \nSample taps should be wiped with alcohol  and flushed for 5 minutes prior to retrieving samples.  Collect all SPS  Samples  in accordance with ST-108    \nBleach should never be used as a disinfectant. \nVendor will bring a calibrated pH meter as pH must be tested immediately at time of draw.\nContainers must be sterile and should be of the required quality not to introduce contamination into the test sample. (eg. Pyrogen-Free, Polypropylene Free, endotoxin-free etc.)\nVendor performing sampling shall use Personal Protective equipment.\nThe Vendor must provide a cooler and ice packs or other effective methods to maintain the required temperature as required by contract requirements.\nTransportation Requirements\nThe contractor is responsible for all transportation and/or shipping while performing under this contract.\nBacterial replication shall be prevented by holding the sample on ice (or through other means of keeping the sample between  1.0 Â°C- 4Â°C [39.2Â°F]) until it is delivered to the laboratory for testing.\nThe recommended maximum elapsed time between collection and analysis of sample  is 8 h (maximum transit time 6 h, maximum processing time 2 h)\nWhen analysis cannot begin within 8 h, maintain sample at a temperature for SPS, maximum elapsed time between collection and analysis must not exceed 24 h.\nAny samples that arrive at the lab out of range shall be resampled within 24 hours of when the sample was taken.\nSamples collected are transported immediately back to vendor laboratories and the endotoxin results are required to be provided to the VA within 48 hours \nSamples collected are transported immediately back to vendor laboratories and the bacterial results are required to be provided to the VA within 72 hours \nSamples collected are transported immediately back to vendor laboratories.  Conductivity, alkalinity, pH, hardness, and ionic composition results are required to be provided to the VA within 5 days.  The vendor shall include maintained temperatures in the sample collection result report.\nLaboratory Requirements\nThe testing laboratory shall have qualified technical support staff for consultation relative to water sample collection, testing, and interpretation results. \nThe testing laboratory processing the water samples for ST-108  compliance with water quality must be certified by the Centers for Disease Control and Prevention (CDC) Environmental AAMI compliance \nOn Demand Retesting\nRetesting is a critical part of the services required. Retesting shall be done within 48 hours of notification or on the next testing day, absent of Saturdays, Sundays or Federal Holidays. Retesting is required for the following: \nAfter out-of-range values as defined in ST-108.  \nAfter system modifications.  Per ST-108,  the loop and associated point of use equipment/fixtures  will be required to be retested in accordance with Appendix B .  The VA Program Manager will specify when this retest is required.  The VA cannot anticipate the total number of frequencies for this retest.  This work will be performed under a separate Task which the vendor will provide a unit cost.   It is estimated the minimum  number of retests for this requirement  is  twice per month.  \n\nReporting and  Chain of Custody Requirements\nAll sample analysis reports shall be emailed to the VAMC designated Point of Contract(s) (POC(s) within, including weekends. Routine analytic reports shall include: \nName and signature of person collecting the sample\nDate, time, pH, and temperature of sample when collected\nDate, time, and temperature when sample arrived in Lab\nBuilding number, room number, room name, area name, as defined in Attachment B \nDate and time  sample was plated/analyzed\nLaboratory and person responsible for performing the analysis\nActual wet signatures or digital if electronic for transfer\nAnalytical technique/method used\nThe  unique laboratory sample identification number/code for the accredited lab\nResults of analysis\n\n\nVendor Qualifications \nWater used for medical device processing must be within the appropriate standards for critical water as listed in AAMI/ANSI ST108 to the point-of-use. \nInternational Organization of Standards (ISO) 9001, 14001\nVendor must be trained in best practices of sample collection, preservation, and must be able to perform on-site testing when necessary.\nVendor qualifications shall include EPA, CDC and ISO (17025) certifications.  \nVendor must possess the ability to perform quality control procedures on reagents and supplies (for sterility and product efficacy), document equipment performance and maintain equipment to manufacturer recommendations as needed to maintain compliance with this Performance Work Statement (PWS).\nVendor shall supply all equipment to complete testing. Equipment may include but is not limited to the following: \nHach DR1900 and DR3900 Spectrophotometers\nYSI Multi Lab 4010-W3\nreactor/heat block, autoclave\npH meter\nTDS meter\nColorimeter\nShaker\nincubator \npipettors\nHeterotrophic Plate Count SM9215\nAmerican National Standard Institute ANSI/AAMI ST108:2023\nClinical & Laboratory Standards Institute (CLSI) guidelines\n\nSchedule\nAll work to install the equipment  will be performed on a Saturday only. The installation is required to be performed in one day. \nAll maintenance and repair work will be performed Monday   Friday  at 5AM   7AM\nAll Water testing must be completed Monday   Friday  7AM   11AM\n\nSecurity Requirements\nVendor is required to have VA approved form of identifications to include a driver s license or photo ID, and Government PIV Contractor Identification card as it applies. ID badge must be always worn by Contractors while on VA premises \nWill need to wear a mask while on the premises and be screened on the way in each day.\nContractor may not have access to the VA network or any VA sensitive information under this contract.\nContractor owned computer equipment including laptops are not permitted to be connected to the VA network\nAll Contractors must receive Privacy training annually using one of the following methods:\nComplete  VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information  training by using VA s TMS system (https://www.tms.va.gov/SecureAuth35/). \nComplete the hard copy version of  VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information . \nSigned training documents must be submitted to VA Point of contact for this contract.  \nTraining must be completed prior to the performance of the contract and annually thereafter. \n\nTask Orders\nAll worked performed under this contract shall only be performed by the contractor via Government issued task orders award against the base contract.\nThe Task Order will include the line items, quantities and associated pricing. All pricing shall be determined directly from the base contract Pricing Schedule.\nEach Task Order will include\nInitial equipment installation   based on a 30-day tank exchange rate \nOverage charge rate for additional DI water VA uses\nAdditional tank exchange due to 7.3.2\nMaintenance fee\nWater testing for ST-108 compliance  per Attachment B\nAdditional water testing based on VA requests\nQuarterly Sanitization of the DI Loop \nAdditional DI Loop sanitization due to VA request \nInvoices will be paid upon satisfactory completion of all project-specific tasks, requirements, and acceptance. Individual purchase order numbers will be issued on each task order for invoicing purposes.\n\nExclusions \nAll Electrical work will be performed by VA\nAll Carpentry work will be performed by VA\nSink removals to provide clearance for the skid mounted DI system will performed by VA \nAlterations to the existing DI water loop.","text":"Department of Veteran Affairs Michael J Crescenz VA Medical Center\nPerformance Work Statement - Sterile Processing Service\nMaintenance Service Contract for Deionized (DI) Water\n\n1.0 Introduction\nThe Michael J Crescenz VA Medical Center, Sterile Processing Services (SPS) requires critical modifications to the existing DI water equipment supplied by Evoqua. These modifications will provide new equipment and additional tanks to adhere to the standards defined by Advancement of Medical Instrumentaiton (AAMI) ST-108.\nThis scope of work is to provide services contract for the initial installation, operations and maintenance service contract for Deionized (DI) Water for Sterile Processing Services areas (SPS) the VA Medical Center to be compliant with the standards defined in this performance work statement. This service contract will be issued as a 3-Year Service Contract.\nThe Contractor shall provide all personnel, equipment, materials, facilities, transportation, tools, water testing services, and supervision to perform these operations and maintenance services to adhere to AAMI ST-108.\n\n2.0 Objective\nThe equipment installed under this contract will be part of a (3) year service maintenance contract. The vendor will be required to provide on-site maintenance to ensure all equipment maintenance and exchanges (DI units, filtration, UV sterilization) will process DI water to meet ST-108 standards.\n\nGiven the critical nature of the instruments SPS sterilizes, there is a direct impact on the operations of Surgery, Ear, Nose, & Throat (ENT), and Gastrointestinal (GI).\n\nAll work must be completed on Saturday. A fully operational and validated system must be completed in one day.\n\nScope\nDesign & Installation\nRemoval of existing Evoqua systems in SPS Mechanical Room. Refer to Attachment A for layout of existing equipment.\nAll Evoqua equipment removed will be disposed of off-site.\nThe VA supplied SPS DI water utilization will be the basis for design of the system.\nThe system will be designed to meet the DI water capacity where anion, cation, and carbon tanks will be replaced every 30 days. The system design is based on the most stringent conditions of high conductivity (total dissolved solids) for the in-coming water during the winter months and DI water usage of 11,000 gallons per month.\n(2) carbon tanks\n(9) exchange tanks\nThe existing DI pipe (1.5 inch diameter ) for the supply and the return will remain. Vendor will attach the system connections to the supply and return line.\nThe VA will create a smaller DI supply and return loop (3/4 ) for sinks #2 and #3. The loop will generate at the DI Skid and return at the skid. Vendor will provide the connections to the DI skid\nSystem will provide primary filter and housing (20 inch) 5 micron\nSystem will provide secondary filter and housing (20 inch) 1 micron\nSystem will provide final filter and housing (20 inch) 0.2 micron\nBacteria destruct ultraviolet sterilization\nFeed & final water quality sensor\nCheck valves on supply and return lines\nFlow meter on supply and return lines\nMain control panel to provide centralized, automated control and monitoring of the entire purification process. System will monitor water quality and manage maintenance cycles.Â\nRecirculation pumps on supply and return lines\nTest valves for water testing validation\nDrain & isolation valves for maintenance\nCheck valves to present reverse flow within system\nThe exchange tanks will be placed in the SPS mechanical room. The remaining equipment will be supplied with a skid mount system placed outside the mechanical room. Hoses will be attached from the skid mount system to the tanks. The VA will provide the open wall section for these hose connections inside the mechanical room. See Sketch 1.\nVendor shall provide ST-108 compliant water testing services for Sterile Processing.\n\nCommissioning\nInspect, test, and verify the system's performance to ensure it meets design objectives to consistently produce DI water to meet ST-108 standards\nQualifications & Inspection\nVerifying the system is installed according to design standards.\nVisual inspection, Pre-treatment checks, Performance tests for flow rate and water conductivity\nCalibration of monitoring instruments\nFinal verification and on-site operator training\nFunctional Testing\nPerformance Testing:Â Measuring the system's flow rate and water conductivity to confirm it meets the required purity standards\nCalibration:Â Calibrating all monitoring instruments, such as resistance meters and flow meters.\nIntegrated System Testing:Â Operating the entire system to ensure all parts work together correctly.\n\nPost-Commissioning\nFinal Verification:Â A final confirmation that the system meets all established criteria and standards.\nInitial Water testing at points of use on the DI system to meet ST-108 requirements. See Attachment B\nOperator Training:Â Providing on-site training\nDocumentation:Â Documenting all test results and the entire commissioning process for future reference and compliance.\nMonitoring & Break-in Period:Â A continuous water sampling and testing period, often 2-4 weeks) is sometimes recommended to monitor performance\n\nMaintenance and Repair\nAll maintenance work shall ensure continuous system operation and compliance to ST-108\nRoutine checks and replacement of filter and UV lamps\nAddressing leaks at hoses and connections\nPumps - replacing worn components\nResin Replacement/Regeneration: replace as required. Design is based on 30-day cycle. Should operation or incoming water conductivity affect higher utilization of tanks, these will be switched next day, which could occur on a weekend.\nInstrument Calibration: Conductivity sensors and other instruments need periodic calibration to ensure accurate water quality monitoring.Â\nLeak Checks: Inspect tanks and piping networks for leaks to prevent contamination and system downtime.Â\nSanitization: Periodically clean and flush the system to remove biofilms and prevent bacterial growth.Â\nAll work scheduled work will be performed Monday Friday 5AM 7AM. Any work requiring more that (2) hours shall be performed on a Saturday\nQuarterly DI loop sanitization.\n\nWater Testing Requirements\nVendor shall furnish all personnel, supervision, certifications, materials, equipment, facilities, results, and resources necessary for water sampling of all locations and frequencies outlined in Attachment B in accordance with ANSI/AAMI ST108 for Sterile Processing. The water quality required from this DI generation system is used for the various stages of medical device processing. Water test results validate system operation for water quality measurement values per ANSI/AAMI ST108 are outlined in Attachment B.\nAseptic technique should be used for water collection. This technique is Â a set of procedures designed to prevent contamination from microorganisms, especially bacteria, viruses, and other pathogens.Â It's a crucial practice in healthcare, laboratory settings, and manufacturing to protect patients, personnel, and products from infections.Â\nSample taps should be wiped with alcohol and flushed for 5 minutes prior to retrieving samples. Collect all SPS Samples in accordance with ST-108\nBleach should never be used as a disinfectant.\nVendor will bring a calibrated pH meter as pH must be tested immediately at time of draw.\nContainers must be sterile and should be of the required quality not to introduce contamination into the test sample. (eg. Pyrogen-Free, Polypropylene Free, endotoxin-free etc.)\nVendor performing sampling shall use Personal Protective equipment.\nThe Vendor must provide a cooler and ice packs or other effective methods to maintain the required temperature as required by contract requirements.\nTransportation Requirements\nThe contractor is responsible for all transportation and/or shipping while performing under this contract.\nBacterial replication shall be prevented by holding the sample on ice (or through other means of keeping the sample between 1.0 Â°C- 4Â°C [39.2Â°F]) until it is delivered to the laboratory for testing.\nThe recommended maximum elapsed time between collection and analysis of sample is 8 h (maximum transit time 6 h, maximum processing time 2 h)\nWhen analysis cannot begin within 8 h, maintain sample at a temperature for SPS, maximum elapsed time between collection and analysis must not exceed 24 h.\nAny samples that arrive at the lab out of range shall be resampled within 24 hours of when the sample was taken.\nSamples collected are transported immediately back to vendor laboratories and the endotoxin results are required to be provided to the VA within 48 hours\nSamples collected are transported immediately back to vendor laboratories and the bacterial results are required to be provided to the VA within 72 hours\nSamples collected are transported immediately back to vendor laboratories. Conductivity, alkalinity, pH, hardness, and ionic composition results are required to be provided to the VA within 5 days. The vendor shall include maintained temperatures in the sample collection result report.\nLaboratory Requirements\nThe testing laboratory shall have qualified technical support staff for consultation relative to water sample collection, testing, and interpretation results.\nThe testing laboratory processing the water samples for ST-108 compliance with water quality must be certified by the Centers for Disease Control and Prevention (CDC) Environmental AAMI compliance\nOn Demand Retesting\nRetesting is a critical part of the services required. Retesting shall be done within 48 hours of notification or on the next testing day, absent of Saturdays, Sundays or Federal Holidays. Retesting is required for the following:\nAfter out-of-range values as defined in ST-108.\nAfter system modifications. Per ST-108, the loop and associated point of use equipment/fixtures will be required to be retested in accordance with Appendix B . The VA Program Manager will specify when this retest is required. The VA cannot anticipate the total number of frequencies for this retest. This work will be performed under a separate Task which the vendor will provide a unit cost. It is estimated the minimum number of retests for this requirement is twice per month.\n\nReporting and Chain of Custody Requirements\nAll sample analysis reports shall be emailed to the VAMC designated Point of Contract(s) (POC(s) within, including weekends. Routine analytic reports shall include:\nName and signature of person collecting the sample\nDate, time, pH, and temperature of sample when collected\nDate, time, and temperature when sample arrived in Lab\nBuilding number, room number, room name, area name, as defined in Attachment B\nDate and time sample was plated/analyzed\nLaboratory and person responsible for performing the analysis\nActual wet signatures or digital if electronic for transfer\nAnalytical technique/method used\nThe unique laboratory sample identification number/code for the accredited lab\nResults of analysis\n\nVendor Qualifications\nWater used for medical device processing must be within the appropriate standards for critical water as listed in AAMI/ANSI ST108 to the point-of-use.\nInternational Organization of Standards (ISO) 9001, 14001\nVendor must be trained in best practices of sample collection, preservation, and must be able to perform on-site testing when necessary.\nVendor qualifications shall include EPA, CDC and ISO (17025) certifications.\nVendor must possess the ability to perform quality control procedures on reagents and supplies (for sterility and product efficacy), document equipment performance and maintain equipment to manufacturer recommendations as needed to maintain compliance with this Performance Work Statement (PWS).\nVendor shall supply all equipment to complete testing. Equipment may include but is not limited to the following:\nHach DR1900 and DR3900 Spectrophotometers\nYSI Multi Lab 4010-W3\nreactor/heat block, autoclave\npH meter\nTDS meter\nColorimeter\nShaker\nincubator\npipettors\nHeterotrophic Plate Count SM9215\nAmerican National Standard Institute ANSI/AAMI ST108:2023\nClinical & Laboratory Standards Institute (CLSI) guidelines\n\nSchedule\nAll work to install the equipment will be performed on a Saturday only. The installation is required to be performed in one day.\nAll maintenance and repair work will be performed Monday Friday at 5AM 7AM\nAll Water testing must be completed Monday Friday 7AM 11AM\n\nSecurity Requirements\nVendor is required to have VA approved form of identifications to include a driver s license or photo ID, and Government PIV Contractor Identification card as it applies. ID badge must be always worn by Contractors while on VA premises\nWill need to wear a mask while on the premises and be screened on the way in each day.\nContractor may not have access to the VA network or any VA sensitive information under this contract.\nContractor owned computer equipment including laptops are not permitted to be connected to the VA network\nAll Contractors must receive Privacy training annually using one of the following methods:\nComplete VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information training by using VA s TMS system (https://www.tms.va.gov/SecureAuth35/).\nComplete the hard copy version of VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information .\nSigned training documents must be submitted to VA Point of contact for this contract.\nTraining must be completed prior to the performance of the contract and annually thereafter.\n\nTask Orders\nAll worked performed under this contract shall only be performed by the contractor via Government issued task orders award against the base contract.\nThe Task Order will include the line items, quantities and associated pricing. All pricing shall be determined directly from the base contract Pricing Schedule.\nEach Task Order will include\nInitial equipment installation based on a 30-day tank exchange rate\nOverage charge rate for additional DI water VA uses\nAdditional tank exchange due to 7.3.2\nMaintenance fee\nWater testing for ST-108 compliance per Attachment B\nAdditional water testing based on VA requests\nQuarterly Sanitization of the DI Loop\nAdditional DI Loop sanitization due to VA request\nInvoices will be paid upon satisfactory completion of all project-specific tasks, requirements, and acceptance. Individual purchase order numbers will be issued on each task order for invoicing purposes.\n\nExclusions\nAll Electrical work will be performed by VA\nAll Carpentry work will be performed by VA\nSink removals to provide clearance for the skid mounted DI system will performed by VA\nAlterations to the existing DI water loop.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24426Q0023","product_service_code":"J046"}],"due_at":"2025-10-22T06:00:00Z","due_date":"2025-10-22","closes_at":"2025-10-22T06:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"site","state_evidence":"ENT OF VETERAN AFFAIRS MICHAEL J CRESCENZ VA MEDICAL CENTER","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-27T01:15:01.980905Z","principal_notice_id":"a22d52788e464e5cbb9d391a8cec8e2b","description":{"text":"Department of Veteran Affairs Michael J Crescenz VA Medical Center\nPerformance Work Statement - Sterile Processing Service\nMaintenance Service Contract for Deionized (DI) Water\n\n1.0 Introduction\nThe Michael J Crescenz VA Medical Center, Sterile Processing Services (SPS) requires critical modifications to the existing DI water equipment supplied by Evoqua. These modifications will provide new equipment and additional tanks to adhere to the standards defined by Advancement of Medical Instrumentaiton (AAMI) ST-108.\nThis scope of work is to provide services contract for the initial installation, operations and maintenance service contract for Deionized (DI) Water for Sterile Processing Services areas (SPS) the VA Medical Center to be compliant with the standards defined in this performance work statement. This service contract will be issued as a 3-Year Service Contract.\nThe Contractor shall provide all personnel, equipment, materials, facilities, transportation, tools, water testing services, and supervision to perform these operations and maintenance services to adhere to AAMI ST-108.\n\n2.0 Objective\nThe equipment installed under this contract will be part of a (3) year service maintenance contract. The vendor will be required to provide on-site maintenance to ensure all equipment maintenance and exchanges (DI units, filtration, UV sterilization) will process DI water to meet ST-108 standards.\n\nGiven the critical nature of the instruments SPS sterilizes, there is a direct impact on the operations of Surgery, Ear, Nose, & Throat (ENT), and Gastrointestinal (GI).\n\nAll work must be completed on Saturday. A fully operational and validated system must be completed in one day.\n\nScope\nDesign & Installation\nRemoval of existing Evoqua systems in SPS Mechanical Room. Refer to Attachment A for layout of existing equipment.\nAll Evoqua equipment removed will be disposed of off-site.\nThe VA supplied SPS DI water utilization will be the basis for design of the system.\nThe system will be designed to meet the DI water capacity where anion, cation, and carbon tanks will be replaced every 30 days. The system design is based on the most stringent conditions of high conductivity (total dissolved solids) for the in-coming water during the winter months and DI water usage of 11,000 gallons per month.\n(2) carbon tanks\n(9) exchange tanks\nThe existing DI pipe (1.5 inch diameter ) for the supply and the return will remain. Vendor will attach the system connections to the supply and return line.\nThe VA will create a smaller DI supply and return loop (3/4 ) for sinks #2 and #3. The loop will generate at the DI Skid and return at the skid. Vendor will provide the connections to the DI skid\nSystem will provide primary filter and housing (20 inch) 5 micron\nSystem will provide secondary filter and housing (20 inch) 1 micron\nSystem will provide final filter and housing (20 inch) 0.2 micron\nBacteria destruct ultraviolet sterilization\nFeed & final water quality sensor\nCheck valves on supply and return lines\nFlow meter on supply and return lines\nMain control panel to provide centralized, automated control and monitoring of the entire purification process. System will monitor water quality and manage maintenance cycles.Â\nRecirculation pumps on supply and return lines\nTest valves for water testing validation\nDrain & isolation valves for maintenance\nCheck valves to present reverse flow within system\nThe exchange tanks will be placed in the SPS mechanical room. The remaining equipment will be supplied with a skid mount system placed outside the mechanical room. Hoses will be attached from the skid mount system to the tanks. The VA will provide the open wall section for these hose connections inside the mechanical room. See Sketch 1.\nVendor shall provide ST-108 compliant water testing services for Sterile Processing.\n\nCommissioning\nInspect, test, and verify the system's performance to ensure it meets design objectives to consistently produce DI water to meet ST-108 standards\nQualifications & Inspection\nVerifying the system is installed according to design standards.\nVisual inspection, Pre-treatment checks, Performance tests for flow rate and water conductivity\nCalibration of monitoring instruments\nFinal verification and on-site operator training\nFunctional Testing\nPerformance Testing:Â Measuring the system's flow rate and water conductivity to confirm it meets the required purity standards\nCalibration:Â Calibrating all monitoring instruments, such as resistance meters and flow meters.\nIntegrated System Testing:Â Operating the entire system to ensure all parts work together correctly.\n\nPost-Commissioning\nFinal Verification:Â A final confirmation that the system meets all established criteria and standards.\nInitial Water testing at points of use on the DI system to meet ST-108 requirements. See Attachment B\nOperator Training:Â Providing on-site training\nDocumentation:Â Documenting all test results and the entire commissioning process for future reference and compliance.\nMonitoring & Break-in Period:Â A continuous water sampling and testing period, often 2-4 weeks) is sometimes recommended to monitor performance\n\nMaintenance and Repair\nAll maintenance work shall ensure continuous system operation and compliance to ST-108\nRoutine checks and replacement of filter and UV lamps\nAddressing leaks at hoses and connections\nPumps - replacing worn components\nResin Replacement/Regeneration: replace as required. Design is based on 30-day cycle. Should operation or incoming water conductivity affect higher utilization of tanks, these will be switched next day, which could occur on a weekend.\nInstrument Calibration: Conductivity sensors and other instruments need periodic calibration to ensure accurate water quality monitoring.Â\nLeak Checks: Inspect tanks and piping networks for leaks to prevent contamination and system downtime.Â\nSanitization: Periodically clean and flush the system to remove biofilms and prevent bacterial growth.Â\nAll work scheduled work will be performed Monday Friday 5AM 7AM. Any work requiring more that (2) hours shall be performed on a Saturday\nQuarterly DI loop sanitization.\n\nWater Testing Requirements\nVendor shall furnish all personnel, supervision, certifications, materials, equipment, facilities, results, and resources necessary for water sampling of all locations and frequencies outlined in Attachment B in accordance with ANSI/AAMI ST108 for Sterile Processing. The water quality required from this DI generation system is used for the various stages of medical device processing. Water test results validate system operation for water quality measurement values per ANSI/AAMI ST108 are outlined in Attachment B.\nAseptic technique should be used for water collection. This technique is Â a set of procedures designed to prevent contamination from microorganisms, especially bacteria, viruses, and other pathogens.Â It's a crucial practice in healthcare, laboratory settings, and manufacturing to protect patients, personnel, and products from infections.Â\nSample taps should be wiped with alcohol and flushed for 5 minutes prior to retrieving samples. Collect all SPS Samples in accordance with ST-108\nBleach should never be used as a disinfectant.\nVendor will bring a calibrated pH meter as pH must be tested immediately at time of draw.\nContainers must be sterile and should be of the required quality not to introduce contamination into the test sample. (eg. Pyrogen-Free, Polypropylene Free, endotoxin-free etc.)\nVendor performing sampling shall use Personal Protective equipment.\nThe Vendor must provide a cooler and ice packs or other effective methods to maintain the required temperature as required by contract requirements.\nTransportation Requirements\nThe contractor is responsible for all transportation and/or shipping while performing under this contract.\nBacterial replication shall be prevented by holding the sample on ice (or through other means of keeping the sample between 1.0 Â°C- 4Â°C [39.2Â°F]) until it is delivered to the laboratory for testing.\nThe recommended maximum elapsed time between collection and analysis of sample is 8 h (maximum transit time 6 h, maximum processing time 2 h)\nWhen analysis cannot begin within 8 h, maintain sample at a temperature for SPS, maximum elapsed time between collection and analysis must not exceed 24 h.\nAny samples that arrive at the lab out of range shall be resampled within 24 hours of when the sample was taken.\nSamples collected are transported immediately back to vendor laboratories and the endotoxin results are required to be provided to the VA within 48 hours\nSamples collected are transported immediately back to vendor laboratories and the bacterial results are required to be provided to the VA within 72 hours\nSamples collected are transported immediately back to vendor laboratories. Conductivity, alkalinity, pH, hardness, and ionic composition results are required to be provided to the VA within 5 days. The vendor shall include maintained temperatures in the sample collection result report.\nLaboratory Requirements\nThe testing laboratory shall have qualified technical support staff for consultation relative to water sample collection, testing, and interpretation results.\nThe testing laboratory processing the water samples for ST-108 compliance with water quality must be certified by the Centers for Disease Control and Prevention (CDC) Environmental AAMI compliance\nOn Demand Retesting\nRetesting is a critical part of the services required. Retesting shall be done within 48 hours of notification or on the next testing day, absent of Saturdays, Sundays or Federal Holidays. Retesting is required for the following:\nAfter out-of-range values as defined in ST-108.\nAfter system modifications. Per ST-108, the loop and associated point of use equipment/fixtures will be required to be retested in accordance with Appendix B . The VA Program Manager will specify when this retest is required. The VA cannot anticipate the total number of frequencies for this retest. This work will be performed under a separate Task which the vendor will provide a unit cost. It is estimated the minimum number of retests for this requirement is twice per month.\n\nReporting and Chain of Custody Requirements\nAll sample analysis reports shall be emailed to the VAMC designated Point of Contract(s) (POC(s) within, including weekends. Routine analytic reports shall include:\nName and signature of person collecting the sample\nDate, time, pH, and temperature of sample when collected\nDate, time, and temperature when sample arrived in Lab\nBuilding number, room number, room name, area name, as defined in Attachment B\nDate and time sample was plated/analyzed\nLaboratory and person responsible for performing the analysis\nActual wet signatures or digital if electronic for transfer\nAnalytical technique/method used\nThe unique laboratory sample identification number/code for the accredited lab\nResults of analysis\n\nVendor Qualifications\nWater used for medical device processing must be within the appropriate standards for critical water as listed in AAMI/ANSI ST108 to the point-of-use.\nInternational Organization of Standards (ISO) 9001, 14001\nVendor must be trained in best practices of sample collection, preservation, and must be able to perform on-site testing when necessary.\nVendor qualifications shall include EPA, CDC and ISO (17025) certifications.\nVendor must possess the ability to perform quality control procedures on reagents and supplies (for sterility and product efficacy), document equipment performance and maintain equipment to manufacturer recommendations as needed to maintain compliance with this Performance Work Statement (PWS).\nVendor shall supply all equipment to complete testing. Equipment may include but is not limited to the following:\nHach DR1900 and DR3900 Spectrophotometers\nYSI Multi Lab 4010-W3\nreactor/heat block, autoclave\npH meter\nTDS meter\nColorimeter\nShaker\nincubator\npipettors\nHeterotrophic Plate Count SM9215\nAmerican National Standard Institute ANSI/AAMI ST108:2023\nClinical & Laboratory Standards Institute (CLSI) guidelines\n\nSchedule\nAll work to install the equipment will be performed on a Saturday only. The installation is required to be performed in one day.\nAll maintenance and repair work will be performed Monday Friday at 5AM 7AM\nAll Water testing must be completed Monday Friday 7AM 11AM\n\nSecurity Requirements\nVendor is required to have VA approved form of identifications to include a driver s license or photo ID, and Government PIV Contractor Identification card as it applies. ID badge must be always worn by Contractors while on VA premises\nWill need to wear a mask while on the premises and be screened on the way in each day.\nContractor may not have access to the VA network or any VA sensitive information under this contract.\nContractor owned computer equipment including laptops are not permitted to be connected to the VA network\nAll Contractors must receive Privacy training annually using one of the following methods:\nComplete VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information training by using VA s TMS system (https://www.tms.va.gov/SecureAuth35/).\nComplete the hard copy version of VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information .\nSigned training documents must be submitted to VA Point of contact for this contract.\nTraining must be completed prior to the performance of the contract and annually thereafter.\n\nTask Orders\nAll worked performed under this contract shall only be performed by the contractor via Government issued task orders award against the base contract.\nThe Task Order will include the line items, quantities and associated pricing. All pricing shall be determined directly from the base contract Pricing Schedule.\nEach Task Order will include\nInitial equipment installation based on a 30-day tank exchange rate\nOverage charge rate for additional DI water VA uses\nAdditional tank exchange due to 7.3.2\nMaintenance fee\nWater testing for ST-108 compliance per Attachment B\nAdditional water testing based on VA requests\nQuarterly Sanitization of the DI Loop\nAdditional DI Loop sanitization due to VA request\nInvoices will be paid upon satisfactory completion of all project-specific tasks, requirements, and acceptance. Individual purchase order numbers will be issued on each task order for invoicing purposes.\n\nExclusions\nAll Electrical work will be performed by VA\nAll Carpentry work will be performed by VA\nSink removals to provide clearance for the skid mounted DI system will performed by VA\nAlterations to the existing DI water loop.","html":"Department of Veteran Affairs Michael J Crescenz VA Medical Center\nPerformance Work Statement  - Sterile Processing Service \nMaintenance Service Contract for Deionized (DI)  Water\n\n1.0 Introduction\nThe Michael J Crescenz VA Medical Center, Sterile Processing Services (SPS) requires critical modifications to the existing DI water equipment supplied by Evoqua. These modifications will provide new equipment and additional tanks to adhere to the standards defined by  Advancement of Medical Instrumentaiton (AAMI) ST-108.  \nThis scope of work is to provide services contract for the initial installation, operations and maintenance service contract  for Deionized (DI) Water for Sterile Processing Services areas (SPS) the VA Medical Center to be compliant with the standards defined in this performance work statement. This service contract will be issued as a  3-Year Service Contract.\nThe Contractor shall provide all personnel, equipment, materials, facilities, transportation, tools, water testing services, and supervision to perform these operations and maintenance services to adhere to AAMI ST-108.\n\n2.0 Objective\nThe equipment installed under this contract will be part of a (3) year service maintenance contract.  The vendor will be required to provide on-site maintenance to ensure all equipment maintenance and exchanges (DI units, filtration, UV sterilization) will process DI water to meet ST-108 standards.\n\nGiven the critical nature of the instruments SPS sterilizes, there is a direct impact on the operations of Surgery, Ear, Nose, & Throat (ENT), and Gastrointestinal (GI). \n\nAll work must be completed on Saturday.  A fully operational and validated system must be completed in one day.    \n\nScope \nDesign & Installation\nRemoval of existing Evoqua systems in SPS Mechanical Room.  Refer to Attachment A for layout of existing equipment. \nAll Evoqua equipment removed will be disposed of off-site.\nThe VA supplied SPS  DI water utilization will be the basis for design of the system.  \nThe system will be designed to meet the DI water capacity  where anion, cation, and carbon tanks will be replaced every 30 days.  The system design is based on the most stringent conditions of high conductivity (total dissolved solids) for the in-coming water during the winter months  and DI water usage of 11,000 gallons per month. \n(2) carbon tanks\n(9) exchange tanks\nThe existing DI  pipe (1.5 inch diameter ) for the supply and the return will remain.  Vendor will attach the system connections to the supply and return line. \nThe VA will create a smaller DI supply and return loop (3/4 ) for sinks #2 and #3.  The loop will generate at the DI Skid and return at the skid. Vendor will provide the connections to the DI skid\nSystem will provide primary filter and housing (20 inch) 5 micron\nSystem will provide secondary filter and housing (20 inch) 1 micron\nSystem will provide final filter and housing (20 inch) 0.2 micron\nBacteria destruct ultraviolet sterilization\nFeed & final water quality sensor \nCheck valves on supply and return lines\nFlow meter on supply and return lines\nMain control panel  to provide centralized, automated control and monitoring of the entire purification process. System will monitor water quality and manage maintenance cycles.Â \nRecirculation pumps on supply and return lines\nTest valves  for water testing validation\n Drain & isolation  valves for maintenance\nCheck valves to present reverse flow within system \nThe exchange tanks will be placed in the SPS mechanical room.  The remaining equipment will be supplied with a skid mount system placed outside the mechanical room.  Hoses will be attached from the skid mount system to the tanks.  The VA will  provide the open wall section for these hose connections inside the mechanical room.  See Sketch 1.\nVendor shall provide ST-108 compliant water testing services for Sterile Processing. \n\n Commissioning \nInspect, test, and verify the system's performance to ensure it meets design objectives to consistently produce  DI water to meet ST-108 standards\nQualifications & Inspection\nVerifying the system is installed according to design standards.\nVisual inspection, Pre-treatment checks, Performance tests for flow rate and water conductivity\nCalibration of monitoring instruments\nFinal verification and on-site operator training\nFunctional Testing\nPerformance Testing:Â Measuring the system's flow rate and water conductivity to confirm it meets the required purity standards \nCalibration:Â Calibrating all monitoring instruments, such as resistance meters and flow meters.\nIntegrated System Testing:Â Operating the entire system to ensure all parts work together correctly.\n\nPost-Commissioning\nFinal Verification:Â A final confirmation that the system meets all established criteria and standards.\nInitial Water testing at points of use on the DI system  to meet ST-108 requirements.  See Attachment B\nOperator Training:Â Providing on-site training\nDocumentation:Â Documenting all test results and the entire commissioning process for future reference and compliance.\nMonitoring & Break-in Period:Â A continuous water sampling and testing period, often 2-4 weeks) is sometimes recommended to monitor performance\n\nMaintenance and Repair\nAll maintenance work  shall ensure continuous system operation and compliance to ST-108\nRoutine checks and replacement of filter  and UV lamps\nAddressing leaks at hoses and connections\nPumps - replacing worn components \nResin Replacement/Regeneration: replace as required.  Design is based on 30-day cycle.  Should operation or incoming water conductivity affect higher utilization of tanks, these will be switched next day, which could occur on a weekend. \nInstrument Calibration: Conductivity sensors and other instruments need periodic calibration to ensure accurate water quality monitoring.Â \nLeak Checks: Inspect tanks and piping networks for leaks to prevent contamination and system downtime.Â \nSanitization: Periodically clean and flush the system to remove biofilms and prevent bacterial growth.Â \nAll work scheduled work will be performed Monday   Friday  5AM   7AM.  Any work requiring more that (2) hours shall be performed on a Saturday \nQuarterly DI loop sanitization.\n\n\nWater Testing Requirements\nVendor shall furnish all personnel, supervision, certifications, materials, equipment, facilities, results, and resources necessary for water sampling of all locations and frequencies outlined in Attachment B in accordance with ANSI/AAMI ST108 for Sterile Processing.  The water quality required from this DI generation system is used for the various stages of medical device processing.  Water test results validate system operation for water quality measurement values per ANSI/AAMI ST108 are outlined in Attachment B. \nAseptic technique should be used for water collection.  This technique is Â a set of procedures designed to prevent contamination from microorganisms, especially bacteria, viruses, and other pathogens.Â It's a crucial practice in healthcare, laboratory settings, and manufacturing to protect patients, personnel, and products from infections.Â \nSample taps should be wiped with alcohol  and flushed for 5 minutes prior to retrieving samples.  Collect all SPS  Samples  in accordance with ST-108    \nBleach should never be used as a disinfectant. \nVendor will bring a calibrated pH meter as pH must be tested immediately at time of draw.\nContainers must be sterile and should be of the required quality not to introduce contamination into the test sample. (eg. Pyrogen-Free, Polypropylene Free, endotoxin-free etc.)\nVendor performing sampling shall use Personal Protective equipment.\nThe Vendor must provide a cooler and ice packs or other effective methods to maintain the required temperature as required by contract requirements.\nTransportation Requirements\nThe contractor is responsible for all transportation and/or shipping while performing under this contract.\nBacterial replication shall be prevented by holding the sample on ice (or through other means of keeping the sample between  1.0 Â°C- 4Â°C [39.2Â°F]) until it is delivered to the laboratory for testing.\nThe recommended maximum elapsed time between collection and analysis of sample  is 8 h (maximum transit time 6 h, maximum processing time 2 h)\nWhen analysis cannot begin within 8 h, maintain sample at a temperature for SPS, maximum elapsed time between collection and analysis must not exceed 24 h.\nAny samples that arrive at the lab out of range shall be resampled within 24 hours of when the sample was taken.\nSamples collected are transported immediately back to vendor laboratories and the endotoxin results are required to be provided to the VA within 48 hours \nSamples collected are transported immediately back to vendor laboratories and the bacterial results are required to be provided to the VA within 72 hours \nSamples collected are transported immediately back to vendor laboratories.  Conductivity, alkalinity, pH, hardness, and ionic composition results are required to be provided to the VA within 5 days.  The vendor shall include maintained temperatures in the sample collection result report.\nLaboratory Requirements\nThe testing laboratory shall have qualified technical support staff for consultation relative to water sample collection, testing, and interpretation results. \nThe testing laboratory processing the water samples for ST-108  compliance with water quality must be certified by the Centers for Disease Control and Prevention (CDC) Environmental AAMI compliance \nOn Demand Retesting\nRetesting is a critical part of the services required. Retesting shall be done within 48 hours of notification or on the next testing day, absent of Saturdays, Sundays or Federal Holidays. Retesting is required for the following: \nAfter out-of-range values as defined in ST-108.  \nAfter system modifications.  Per ST-108,  the loop and associated point of use equipment/fixtures  will be required to be retested in accordance with Appendix B .  The VA Program Manager will specify when this retest is required.  The VA cannot anticipate the total number of frequencies for this retest.  This work will be performed under a separate Task which the vendor will provide a unit cost.   It is estimated the minimum  number of retests for this requirement  is  twice per month.  \n\nReporting and  Chain of Custody Requirements\nAll sample analysis reports shall be emailed to the VAMC designated Point of Contract(s) (POC(s) within, including weekends. Routine analytic reports shall include: \nName and signature of person collecting the sample\nDate, time, pH, and temperature of sample when collected\nDate, time, and temperature when sample arrived in Lab\nBuilding number, room number, room name, area name, as defined in Attachment B \nDate and time  sample was plated/analyzed\nLaboratory and person responsible for performing the analysis\nActual wet signatures or digital if electronic for transfer\nAnalytical technique/method used\nThe  unique laboratory sample identification number/code for the accredited lab\nResults of analysis\n\n\nVendor Qualifications \nWater used for medical device processing must be within the appropriate standards for critical water as listed in AAMI/ANSI ST108 to the point-of-use. \nInternational Organization of Standards (ISO) 9001, 14001\nVendor must be trained in best practices of sample collection, preservation, and must be able to perform on-site testing when necessary.\nVendor qualifications shall include EPA, CDC and ISO (17025) certifications.  \nVendor must possess the ability to perform quality control procedures on reagents and supplies (for sterility and product efficacy), document equipment performance and maintain equipment to manufacturer recommendations as needed to maintain compliance with this Performance Work Statement (PWS).\nVendor shall supply all equipment to complete testing. Equipment may include but is not limited to the following: \nHach DR1900 and DR3900 Spectrophotometers\nYSI Multi Lab 4010-W3\nreactor/heat block, autoclave\npH meter\nTDS meter\nColorimeter\nShaker\nincubator \npipettors\nHeterotrophic Plate Count SM9215\nAmerican National Standard Institute ANSI/AAMI ST108:2023\nClinical & Laboratory Standards Institute (CLSI) guidelines\n\nSchedule\nAll work to install the equipment  will be performed on a Saturday only. The installation is required to be performed in one day. \nAll maintenance and repair work will be performed Monday   Friday  at 5AM   7AM\nAll Water testing must be completed Monday   Friday  7AM   11AM\n\nSecurity Requirements\nVendor is required to have VA approved form of identifications to include a driver s license or photo ID, and Government PIV Contractor Identification card as it applies. ID badge must be always worn by Contractors while on VA premises \nWill need to wear a mask while on the premises and be screened on the way in each day.\nContractor may not have access to the VA network or any VA sensitive information under this contract.\nContractor owned computer equipment including laptops are not permitted to be connected to the VA network\nAll Contractors must receive Privacy training annually using one of the following methods:\nComplete  VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information  training by using VA s TMS system (https://www.tms.va.gov/SecureAuth35/). \nComplete the hard copy version of  VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or Use to VA Sensitive Information . \nSigned training documents must be submitted to VA Point of contact for this contract.  \nTraining must be completed prior to the performance of the contract and annually thereafter. \n\nTask Orders\nAll worked performed under this contract shall only be performed by the contractor via Government issued task orders award against the base contract.\nThe Task Order will include the line items, quantities and associated pricing. All pricing shall be determined directly from the base contract Pricing Schedule.\nEach Task Order will include\nInitial equipment installation   based on a 30-day tank exchange rate \nOverage charge rate for additional DI water VA uses\nAdditional tank exchange due to 7.3.2\nMaintenance fee\nWater testing for ST-108 compliance  per Attachment B\nAdditional water testing based on VA requests\nQuarterly Sanitization of the DI Loop \nAdditional DI Loop sanitization due to VA request \nInvoices will be paid upon satisfactory completion of all project-specific tasks, requirements, and acceptance. Individual purchase order numbers will be issued on each task order for invoicing purposes.\n\nExclusions \nAll Electrical work will be performed by VA\nAll Carpentry work will be performed by VA\nSink removals to provide clearance for the skid mounted DI system will performed by VA \nAlterations to the existing DI water loop.","origin":"detail"},"contacts":[{"name":"DEREK M CHUFF","role":"primary","email":"DEREK.CHUFF@va.gov","phone":"814-943-8164","title":"Derek.Chuff@va.gov"}],"place_of_performance":null,"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"d4690e63482c4fa19c2ead39500fb1f6","name":"36C24426Q0023_1.docx","kind":"file","mime_type":".docx","size_bytes":35271,"posted_at":"2025-10-07T17:25:58.686Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d4690e63482c4fa19c2ead39500fb1f6/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24427Q0073","latest_notice_id":"130d1e906067454a9520ca90284294e5","title":"J046--IDIQ | Deionization Water System Maintenance and Support","solicitation_number":"36C24427Q0073","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-09T18:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"221310","psc":"J046","set_aside":null,"state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"4BADF0FAA275492A8898366F3CFCB4F9","latest_notice_id":"4badf0faa275492a8898366f3cfcb4f9","title":"Notice of Intent to Sole Source - SmartLab X-ray Diffractometer (XRD) Service Agreement - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"B8164D58E343480FAF72E235E2A2B7BA","latest_notice_id":"b8164d58e343480faf72e235e2a2b7ba","title":"Notice of Intent to Sole Source - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W51AA127QA004","latest_notice_id":"8fe637fd4a2e485d9897807458fad1e1","title":"400 Hz Cycle Converters - Maintenance, Inspections, and Repairs","solicitation_number":"W51AA127QA004","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-14T21:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51AA1","office_name":"W6QK ACC-APG CONT CT TYAD OFC","naics":"811210","psc":"J059","set_aside":"SBA","state":"PA","county":"42089","county_name":"Monroe County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":59,"indexable":false}