{"canonical":"https://sealedbidder.com/opportunities/36c24425q0787","key":"36C24425Q0787","url":"https://sealedbidder.com/opportunities/36c24425q0787","title":"6515--Brand Name or Equal to two (2) Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT Centrifuges. This is not a Request for Quote","solicitation_number":"36C24425Q0787","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-30T20:00:00Z","first_posted":"2025-06-23","last_posted":"2025-06-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339113","psc":"6515","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"42049","place_county_name":"Erie County","place_city":"4224000","place_city_name":"Erie","winner":null,"award_amount":null,"publications":[{"notice_id":"e98c393d6e80400eae5c6f45baa143cd","title":"6515--Brand Name or Equal to two (2) Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT Centrifuges. This is not a Request for Quote","solicitation_number":"36C24425Q0787","notice_type":"r","base_type":"r","posted":"2025-06-23","posted_at":"2025-06-23T19:02:35.092Z","due_at":"2025-06-30T20:00:00Z","due_date":"2025-06-30","cancelled":false,"archived":true,"archive_date":"2025-08-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e98c393d6e80400eae5c6f45baa143cd/view","enriched":true,"history":[{"index":3,"title":"6515--Brand Name or Equal to two (2) Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT Centrifuges. This is not a Request for Quote","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-23T19:02:35.092Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e98c393d6e80400eae5c6f45baa143cd","solicitation_number":"36C24425Q0787"}]}],"latest_notice_id":"e98c393d6e80400eae5c6f45baa143cd","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-23","posted_at":"2025-06-23T19:02:35.092Z","created_at":"2025-06-23T19:02:07.258Z","modified_at":"2025-08-29T04:04:37.364Z","response_deadline":{"raw":"2025-06-30T16:00:00-04:00","utc":"2025-06-30T20:00:00Z","date":"2025-06-30","time":"16:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e98c393d6e80400eae5c6f45baa143cd/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Brand Name or Equal to two (2) Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT Centrifuges. This is not a Request for Quote","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Brand Name or Equal to two (2) Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT Centrifuges. This is not a Request for Quote","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-23T19:02:35.092Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e98c393d6e80400eae5c6f45baa143cd","solicitation_number":"36C24425Q0787"}],"contacts":[{"name":"David Santiago","role":"primary","email":"david.santiago2@va.gov","phone":"412-822-3746","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e98c393d6e80400eae5c6f45baa143cd","lineage_id":"e98c393d6e80400eae5c6f45baa143cd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T03:09:30.774054057Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5cec63fe9b03482611fb8406f9d9c5343ded813205b4ab05bd73376feb19d477","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T03:09:30.774054057Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Statement of Need (SON)\nDepartment of Veterans Affairs \nErie VA Medical Center (EVAMC)\n135 E. 38th Street, \nErie, PA. 16504\n\n\nBackground:  The Department of Veterans Affairs, Erie VA Medical Center (EVAMC), has a new requirement for two (2) Brand Name or Equal to Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges used for specimen separation of plasma/serum from red blood cells. The two (2) laboratory centrifuges are going to be used in the core lab of Pathology & Laboratory Medicine. The Erie VA Medical Center is replacing their current centrifuges due to repeated work orders within the last year.  With the needed salient characteristic of a  clear cover , these centrifuges will allow staff to complete work more efficiently as they will be able to just glance into the centrifuge to see if specimens are ready for testing.\n\nSalient Features (Brand Name or Equal):\nMust be suitable for tabletop placement.\nMotor must be 1 horsepower direct drive and brushless.\nMust contain simultaneous digital RPM (revolutions per minute) and RCF (relative centrifugal force) display.\nSpeed must be customizable in RPM or RCF.\nMust contain digital time display with timer range between 1-999.\nTimer must have  hold  function.\nMust allow the ability to save and recall up to three speed and time configurations.\nSettings must be  lockable  to prevent accidental and non-authorized changes.\nRotor chamber must be completely enclosed.\nConfiguration of rotor must be horizontal or  swinging  bucket style.\nLid must be see-through,  clear cover .  \nLid must be closed and locked to operate.\nSafety mechanism must prevent lid access while operating.\nMust contain audible end of run indicator alert.\nAdapters must accommodate both 13mm (5mL, 7mL) and 16mm (10mL) tube diameters.\nMust accommodate up to 40 blood tubes of varying dimensions.\nFootprint must not exceed 20 in width, 25 in depth, 16 in height when door is closed.\nElectrical power must not exceed 120V/60Hz.\nTraining and Installation:\nTraining and installation not required.  \n\nSECURITY & PRIVACY CONTROL: \nThe Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement; therefore, a Security Accreditation package is not required. No C&A nor MOU/ISA is required. Sensitive information exposure as part of this contract involves applicable security controls within the facility as part of the VA Information Security Program.\nIf there are any questions related to privacy, please have a member of your staff contact the VA Privacy Service at 202-461-6309. If there are any questions related to the information security, please have a member of your staff contacts the Office of Cyber Security at 304-262-7733.\n\n\nGOVERNMENT FURNISHED INFORMATION OR MATERIAL:\n\nThis acquisition does not include Government-furnished property (GFP).\n\nThis acquisition does not include Contractor-acquired property (CAP). \n\n\n\nEnd-User/Facility POC: Bernadette Hall, Supervisor, Pathology & Laboratory Medicine\n\nAcquisition Utilization Specialist: Jill Friend\n\n \nDelivery:\nAll items must be FOB Destination, 30 Days ARO, to the following location:\nErie VA Medical Center\nAttn: Distribution Center\n135 E. 38th Street\nErie, PA  16504\n\nMonday   Friday from 8:00am   4:00pm\nCONTRACTOR QUALIFICATIONS:  \n\nNot applicable for this acquisition.\n\n\nSECURITY/NATIONAL AGENCY CHECK REQUIREMENTS:\n\nNot applicable for this acquisition.\n\n\n\nInstructions to Vendors:\nThe information identified above is intended to be descriptive, of the BRAND NAME or EQUAL to - Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. \nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339113. \n\nPlease answer the following questions: \n\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? \n\n\nIs your company considered small under the NAICS code identified under this RFI? \n\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above? \n\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). \n\n\nDescribe how your small business takes ownership of the equipment in the manufacturing, assembly, or delivery process. \n\n\n\n(6) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? \n\n\n\n(7) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. \n\n\n\n(8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. \n\n\n(9) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? \n\n\n\n(10) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. \n\n\n\n(11) Please submit your capabilities regarding the brand name equipment. \n\n\n\n(12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. \n\n\n\n\n\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Responses must be received via email to david.santiago2@va.gov no later than, 4 PM Eastern Standard Time (EST) on Monday June 30, 2025. This notice will help the VA in determining available potential sources only. Reference 36C24425Q0787 in the subject of the email response. \n\nDo not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, David Santiago. \n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award.\n \nIf a solicitation is issued, information will be posted on the Sam.gov web site for all qualified interested parties at a later date and interested parties must respond to this notification to be considered for a set-aside. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by email to Contracting Specialist at david.santiago2@va.gov \n\n\n\n\n\nDISCLAIMER \n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","text":"Statement of Need (SON)\nDepartment of Veterans Affairs\nErie VA Medical Center (EVAMC)\n135 E. 38th Street,\nErie, PA. 16504\n\nBackground: The Department of Veterans Affairs, Erie VA Medical Center (EVAMC), has a new requirement for two (2) Brand Name or Equal to Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges used for specimen separation of plasma/serum from red blood cells. The two (2) laboratory centrifuges are going to be used in the core lab of Pathology & Laboratory Medicine. The Erie VA Medical Center is replacing their current centrifuges due to repeated work orders within the last year. With the needed salient characteristic of a clear cover , these centrifuges will allow staff to complete work more efficiently as they will be able to just glance into the centrifuge to see if specimens are ready for testing.\n\nSalient Features (Brand Name or Equal):\nMust be suitable for tabletop placement.\nMotor must be 1 horsepower direct drive and brushless.\nMust contain simultaneous digital RPM (revolutions per minute) and RCF (relative centrifugal force) display.\nSpeed must be customizable in RPM or RCF.\nMust contain digital time display with timer range between 1-999.\nTimer must have hold function.\nMust allow the ability to save and recall up to three speed and time configurations.\nSettings must be lockable to prevent accidental and non-authorized changes.\nRotor chamber must be completely enclosed.\nConfiguration of rotor must be horizontal or swinging bucket style.\nLid must be see-through, clear cover .\nLid must be closed and locked to operate.\nSafety mechanism must prevent lid access while operating.\nMust contain audible end of run indicator alert.\nAdapters must accommodate both 13mm (5mL, 7mL) and 16mm (10mL) tube diameters.\nMust accommodate up to 40 blood tubes of varying dimensions.\nFootprint must not exceed 20 in width, 25 in depth, 16 in height when door is closed.\nElectrical power must not exceed 120V/60Hz.\nTraining and Installation:\nTraining and installation not required.\n\nSECURITY & PRIVACY CONTROL:\nThe Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement; therefore, a Security Accreditation package is not required. No C&A nor MOU/ISA is required. Sensitive information exposure as part of this contract involves applicable security controls within the facility as part of the VA Information Security Program.\nIf there are any questions related to privacy, please have a member of your staff contact the VA Privacy Service at 202-461-6309. If there are any questions related to the information security, please have a member of your staff contacts the Office of Cyber Security at 304-262-7733.\n\nGOVERNMENT FURNISHED INFORMATION OR MATERIAL:\n\nThis acquisition does not include Government-furnished property (GFP).\n\nThis acquisition does not include Contractor-acquired property (CAP).\n\nEnd-User/Facility POC: Bernadette Hall, Supervisor, Pathology & Laboratory Medicine\n\nAcquisition Utilization Specialist: Jill Friend\n\nDelivery:\nAll items must be FOB Destination, 30 Days ARO, to the following location:\nErie VA Medical Center\nAttn: Distribution Center\n135 E. 38th Street\nErie, PA 16504\n\nMonday Friday from 8:00am 4:00pm\nCONTRACTOR QUALIFICATIONS:\n\nNot applicable for this acquisition.\n\nSECURITY/NATIONAL AGENCY CHECK REQUIREMENTS:\n\nNot applicable for this acquisition.\n\nInstructions to Vendors:\nThe information identified above is intended to be descriptive, of the BRAND NAME or EQUAL to - Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339113.\n\nPlease answer the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nDescribe how your small business takes ownership of the equipment in the manufacturing, assembly, or delivery process.\n\n(6) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\n(7) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n\n(8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\n\n(9) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\n\n(10) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n\n(11) Please submit your capabilities regarding the brand name equipment.\n\n(12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Responses must be received via email to david.santiago2@va.gov no later than, 4 PM Eastern Standard Time (EST) on Monday June 30, 2025. This notice will help the VA in determining available potential sources only. Reference 36C24425Q0787 in the subject of the email response.\n\nDo not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, David Santiago.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award.\n\nIf a solicitation is issued, information will be posted on the Sam.gov web site for all qualified interested parties at a later date and interested parties must respond to this notification to be considered for a set-aside. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by email to Contracting Specialist at david.santiago2@va.gov\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24425Q0787","place_of_performance":{"zip":"16504","city":{"name":"Erie,"},"state":{"name":"PA."},"street":"Erie VA Medical Center (EVAMC) Attn: Warehouse","country":{"code":"USA","name":"UNITED STATES"},"street2":"135 E. 38th Street,"},"product_service_code":"6515"}],"due_at":"2025-06-30T20:00:00Z","due_date":"2025-06-30","closes_at":"2025-06-30T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":"42049","county_name":"Erie County","city":"4224000","city_name":"Erie","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-12T03:21:38.377453Z","principal_notice_id":"e98c393d6e80400eae5c6f45baa143cd","description":{"text":"Statement of Need (SON)\nDepartment of Veterans Affairs\nErie VA Medical Center (EVAMC)\n135 E. 38th Street,\nErie, PA. 16504\n\nBackground: The Department of Veterans Affairs, Erie VA Medical Center (EVAMC), has a new requirement for two (2) Brand Name or Equal to Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges used for specimen separation of plasma/serum from red blood cells. The two (2) laboratory centrifuges are going to be used in the core lab of Pathology & Laboratory Medicine. The Erie VA Medical Center is replacing their current centrifuges due to repeated work orders within the last year. With the needed salient characteristic of a clear cover , these centrifuges will allow staff to complete work more efficiently as they will be able to just glance into the centrifuge to see if specimens are ready for testing.\n\nSalient Features (Brand Name or Equal):\nMust be suitable for tabletop placement.\nMotor must be 1 horsepower direct drive and brushless.\nMust contain simultaneous digital RPM (revolutions per minute) and RCF (relative centrifugal force) display.\nSpeed must be customizable in RPM or RCF.\nMust contain digital time display with timer range between 1-999.\nTimer must have hold function.\nMust allow the ability to save and recall up to three speed and time configurations.\nSettings must be lockable to prevent accidental and non-authorized changes.\nRotor chamber must be completely enclosed.\nConfiguration of rotor must be horizontal or swinging bucket style.\nLid must be see-through, clear cover .\nLid must be closed and locked to operate.\nSafety mechanism must prevent lid access while operating.\nMust contain audible end of run indicator alert.\nAdapters must accommodate both 13mm (5mL, 7mL) and 16mm (10mL) tube diameters.\nMust accommodate up to 40 blood tubes of varying dimensions.\nFootprint must not exceed 20 in width, 25 in depth, 16 in height when door is closed.\nElectrical power must not exceed 120V/60Hz.\nTraining and Installation:\nTraining and installation not required.\n\nSECURITY & PRIVACY CONTROL:\nThe Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement; therefore, a Security Accreditation package is not required. No C&A nor MOU/ISA is required. Sensitive information exposure as part of this contract involves applicable security controls within the facility as part of the VA Information Security Program.\nIf there are any questions related to privacy, please have a member of your staff contact the VA Privacy Service at 202-461-6309. If there are any questions related to the information security, please have a member of your staff contacts the Office of Cyber Security at 304-262-7733.\n\nGOVERNMENT FURNISHED INFORMATION OR MATERIAL:\n\nThis acquisition does not include Government-furnished property (GFP).\n\nThis acquisition does not include Contractor-acquired property (CAP).\n\nEnd-User/Facility POC: Bernadette Hall, Supervisor, Pathology & Laboratory Medicine\n\nAcquisition Utilization Specialist: Jill Friend\n\nDelivery:\nAll items must be FOB Destination, 30 Days ARO, to the following location:\nErie VA Medical Center\nAttn: Distribution Center\n135 E. 38th Street\nErie, PA 16504\n\nMonday Friday from 8:00am 4:00pm\nCONTRACTOR QUALIFICATIONS:\n\nNot applicable for this acquisition.\n\nSECURITY/NATIONAL AGENCY CHECK REQUIREMENTS:\n\nNot applicable for this acquisition.\n\nInstructions to Vendors:\nThe information identified above is intended to be descriptive, of the BRAND NAME or EQUAL to - Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above.\nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339113.\n\nPlease answer the following questions:\n\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n\nIs your company considered small under the NAICS code identified under this RFI?\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above?\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).\n\nDescribe how your small business takes ownership of the equipment in the manufacturing, assembly, or delivery process.\n\n(6) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?\n\n(7) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n\n(8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number.\n\n(9) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?\n\n(10) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n\n(11) Please submit your capabilities regarding the brand name equipment.\n\n(12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Responses must be received via email to david.santiago2@va.gov no later than, 4 PM Eastern Standard Time (EST) on Monday June 30, 2025. This notice will help the VA in determining available potential sources only. Reference 36C24425Q0787 in the subject of the email response.\n\nDo not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, David Santiago.\n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award.\n\nIf a solicitation is issued, information will be posted on the Sam.gov web site for all qualified interested parties at a later date and interested parties must respond to this notification to be considered for a set-aside. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by email to Contracting Specialist at david.santiago2@va.gov\n\nDISCLAIMER\n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","html":"Statement of Need (SON)\nDepartment of Veterans Affairs \nErie VA Medical Center (EVAMC)\n135 E. 38th Street, \nErie, PA. 16504\n\n\nBackground:  The Department of Veterans Affairs, Erie VA Medical Center (EVAMC), has a new requirement for two (2) Brand Name or Equal to Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges used for specimen separation of plasma/serum from red blood cells. The two (2) laboratory centrifuges are going to be used in the core lab of Pathology & Laboratory Medicine. The Erie VA Medical Center is replacing their current centrifuges due to repeated work orders within the last year.  With the needed salient characteristic of a  clear cover , these centrifuges will allow staff to complete work more efficiently as they will be able to just glance into the centrifuge to see if specimens are ready for testing.\n\nSalient Features (Brand Name or Equal):\nMust be suitable for tabletop placement.\nMotor must be 1 horsepower direct drive and brushless.\nMust contain simultaneous digital RPM (revolutions per minute) and RCF (relative centrifugal force) display.\nSpeed must be customizable in RPM or RCF.\nMust contain digital time display with timer range between 1-999.\nTimer must have  hold  function.\nMust allow the ability to save and recall up to three speed and time configurations.\nSettings must be  lockable  to prevent accidental and non-authorized changes.\nRotor chamber must be completely enclosed.\nConfiguration of rotor must be horizontal or  swinging  bucket style.\nLid must be see-through,  clear cover .  \nLid must be closed and locked to operate.\nSafety mechanism must prevent lid access while operating.\nMust contain audible end of run indicator alert.\nAdapters must accommodate both 13mm (5mL, 7mL) and 16mm (10mL) tube diameters.\nMust accommodate up to 40 blood tubes of varying dimensions.\nFootprint must not exceed 20 in width, 25 in depth, 16 in height when door is closed.\nElectrical power must not exceed 120V/60Hz.\nTraining and Installation:\nTraining and installation not required.  \n\nSECURITY & PRIVACY CONTROL: \nThe Certification & Accreditation (C&A) requirements of VHA Handbook 6500.6 do not apply to this requirement; therefore, a Security Accreditation package is not required. No C&A nor MOU/ISA is required. Sensitive information exposure as part of this contract involves applicable security controls within the facility as part of the VA Information Security Program.\nIf there are any questions related to privacy, please have a member of your staff contact the VA Privacy Service at 202-461-6309. If there are any questions related to the information security, please have a member of your staff contacts the Office of Cyber Security at 304-262-7733.\n\n\nGOVERNMENT FURNISHED INFORMATION OR MATERIAL:\n\nThis acquisition does not include Government-furnished property (GFP).\n\nThis acquisition does not include Contractor-acquired property (CAP). \n\n\n\nEnd-User/Facility POC: Bernadette Hall, Supervisor, Pathology & Laboratory Medicine\n\nAcquisition Utilization Specialist: Jill Friend\n\n \nDelivery:\nAll items must be FOB Destination, 30 Days ARO, to the following location:\nErie VA Medical Center\nAttn: Distribution Center\n135 E. 38th Street\nErie, PA  16504\n\nMonday   Friday from 8:00am   4:00pm\nCONTRACTOR QUALIFICATIONS:  \n\nNot applicable for this acquisition.\n\n\nSECURITY/NATIONAL AGENCY CHECK REQUIREMENTS:\n\nNot applicable for this acquisition.\n\n\n\nInstructions to Vendors:\nThe information identified above is intended to be descriptive, of the BRAND NAME or EQUAL to - Global Focus Marketing & Distribution (GFMD) Stealth-H34 Brushless TT laboratory centrifuges to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. \nResponses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339113. \n\nPlease answer the following questions: \n\nPlease indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? \n\n\nIs your company considered small under the NAICS code identified under this RFI? \n\n\nAre you the manufacturer, distributor, or an equivalent solution to the items being referenced above? \n\n\nIf you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). \n\n\nDescribe how your small business takes ownership of the equipment in the manufacturing, assembly, or delivery process. \n\n\n\n(6) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? \n\n\n\n(7) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. \n\n\n\n(8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. \n\n\n(9) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? \n\n\n\n(10) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. \n\n\n\n(11) Please submit your capabilities regarding the brand name equipment. \n\n\n\n(12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. \n\n\n\n\n\nThis RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Responses must be received via email to david.santiago2@va.gov no later than, 4 PM Eastern Standard Time (EST) on Monday June 30, 2025. This notice will help the VA in determining available potential sources only. Reference 36C24425Q0787 in the subject of the email response. \n\nDo not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, David Santiago. \n\nAll firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award.\n \nIf a solicitation is issued, information will be posted on the Sam.gov web site for all qualified interested parties at a later date and interested parties must respond to this notification to be considered for a set-aside. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by email to Contracting Specialist at david.santiago2@va.gov \n\n\n\n\n\nDISCLAIMER \n\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"contacts":[{"name":"David Santiago","role":"primary","email":"david.santiago2@va.gov","phone":"412-822-3746","title":"Contract Specialist"}],"place_of_performance":{"zip":"16504","city":{"name":"Erie,"},"state":{"name":"PA."},"street":"Erie VA Medical Center (EVAMC) Attn: Warehouse","country":{"code":"USA","name":"UNITED STATES"},"street2":"135 E. 38th Street,"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"ac78daf4214146f28ef5a27d141de77d","name":"36C24425Q0787.docx","kind":"file","mime_type":".docx","size_bytes":22169,"posted_at":"2025-06-23T19:02:35.092Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ac78daf4214146f28ef5a27d141de77d/download","mirrored":false},{"resource_id":"d2a0ed48867c4945a324a8762417faea","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-06-23T19:02:35.092Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/erie-health-care/","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24427Q0053","latest_notice_id":"7935eeaee4d94638addddf105e1e7449","title":"Q510--Bedside Somatosensory Evoked Potential (SSEP) Studies VA Pittsburgh Healthcare System","solicitation_number":"36C24427Q0053","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"621399","psc":"Q510","set_aside":null,"state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":"15240","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T01:26:57.794874Z"}],"similar_open":[{"key":"SPE1C127RXXXX","latest_notice_id":"96f1420d810b42fe9c8a1577ab1517db","title":"Informal Market Research Survey – High-Cut Ballistic Helmets","solicitation_number":"SPE1C1-27-R-XXXX","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-10T20:00:00Z","due_date":"2026-12-10","closes_at":"2026-12-10T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE1C1","office_name":"DLA TROOP SUPPORT","naics":"339113","psc":"8470","set_aside":null,"state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":20,"indexable":false}